1
|
Cosseddu F, Shytaj S, Ipponi E, D'Arienzo A, Capanna R, Andreani L. Reconstruction after Pelvic Bone Massive Resection: Evolution and Actuality of 3D-Printing Technology. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA 2024; 91:9-16. [PMID: 38447560 DOI: 10.55095/achot2024/004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
PURPOSE OF THE STUDY Pelvic reconstructions after massive bone resections are among the most challenging practices in orthopedic surgery. Whether the bone gap results after a trauma, a tumor resection, or it is due to a prosthetic revision, it is mandatory to reconstruct pelvic bone continuity and rebuild the functional thread that connects spine and hip joint. Several different approaches have been described in literature through the decades to achieve those goals. MATERIAL AND METHODS To this date, 3D-printed implants represent one of the most promising surgical technologies in orthopedic oncology and complex reconstructive surgery. We present our experience with 3D-printed custom-made pelvic prostheses to fulfi ll bone gaps resulting from massive bone loss due to tumor resections. We retrospectively evaluated 17 cases treated with pelvic bone reconstruction using 3D-printed prostheses. Cases were evaluated in terms of both oncological and functional outcomes. RESULTS At the last follow-up, local complications were found in 6 cases (36%): in 4 (23.5%) of them the cause was a local recurrence of the disease, whereas only 2 (12.5%) had non-oncologic issues. The mean MSTS score in our population increased from 8.2 before surgery to 22.3 at the latest clinical control after surgery. DISCUSSION 3D-printing technology, used to produce cutting jigs and prosthetic implants, can lead to good clinical and functional outcomes. These encouraging results are comparable with the ones obtained with other more frequently used reconstructive approaches and support custom-made implants as a promising reconstructive approach. CONCLUSIONS Our data confi rm 3D-printing and custom-made implants as promising technologies that could shape the next future of orthopedic oncology and reconstructive surgery. KEY WORDS custom made prosthesis, pelvic reconstruction, orthopedic oncology, cutting jigs, 3D-printing.
Collapse
Affiliation(s)
- F Cosseddu
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| | - S Shytaj
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| | - E Ipponi
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| | - A D'Arienzo
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| | - R Capanna
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| | - L Andreani
- University of Pisa, Department of Orthopedic and Trauma Surgery, Pisa, Italy
| |
Collapse
|
2
|
Kwan YH, Owyang D, Ho SWL, Yam MGJ. 3D-printed patient specific surgical guides: Balancing accuracy with practicality. J Clin Orthop Trauma 2023; 46:102293. [PMID: 38130631 PMCID: PMC10731221 DOI: 10.1016/j.jcot.2023.102293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
Introduction Three-dimensional (3D) printing technology has been used in orthopaedic surgery in recent years to manufacture customized surgical cutting jigs. However, there is scarcity of literature and information regarding the optimal parameters of an ideal jig. Our study aims to determine the optimum parameters to design surgical jigs that can produce accurate cuts, and remain practical for use, to serve as a guide for jig creation in future. Methods and materials A biomechanical lab study was designed to investigate whether the thickness of a jig and the height of its cutting slot can significantly affect cutting accuracy. Surgical jigs were 3D printed in medical grade, and an oscillating sawblade was used to mimic intraoperative surgical cuts through the cutting slots onto wooden blocks, which were then analysed to determine the accuracy of cuts. Results Statistical analysis was performed on a total of 72 cuts. The cutting accuracy increased when the thickness of the jig increased, at all slot heights. The cutting accuracy also increased as the slot height decreased, at all jig thicknesses. Overall, the parameters for jig construction that yielded the most accurate cuts were a jig thickness of 15 mm, in combination with a slot height of 100 % of the width of the sawblade. Additionally, at a jig thickness of 15 mm, there was no statistically significant difference in cutting accuracy when increasing the slot height to 120 %. Conclusion This study is the first to propose tangible parameters that can be applied to surgical jig construction to obtain reproducible accurate cuts. Provided that a jig of 15 mm thickness can be accommodated by the size of the wound, the ideal surgical jig with a superior balance of accuracy and useability is 15 mm thick, with a cutting slot height of 120 % of the sawblade thickness.
Collapse
Affiliation(s)
- Yiu Hin Kwan
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore
| | - Dean Owyang
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore
| | - Sean Wei Loong Ho
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore
| | - Michael Gui Jie Yam
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore
| |
Collapse
|
3
|
Bruschi A, Donati DM, Di Bella C. What to choose in bone tumour resections? Patient specific instrumentation versus surgical navigation: a systematic review. J Bone Oncol 2023; 42:100503. [PMID: 37771750 PMCID: PMC10522906 DOI: 10.1016/j.jbo.2023.100503] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 09/01/2023] [Accepted: 09/12/2023] [Indexed: 09/30/2023] Open
Abstract
Patient specific instrumentation (PSI) and intraoperative surgical navigation (SN) can significantly help in achieving wide oncological margins while sparing bone stock in bone tumour resections. This is a systematic review aimed to compare the two techniques on oncological and functional results, preoperative time for surgical planning, surgical intraoperative time, intraoperative technical complications and learning curve. The protocol was registered in PROSPERO database (CRD42023422065). 1613 papers were identified and 81 matched criteria for PRISMA inclusion and eligibility. PSI and SN showed similar results in margins (0-19% positive margins rate), bone cut accuracy (0.3-4 mm of error from the planned), local recurrence and functional reconstruction scores (MSTS 81-97%) for both long bones and pelvis, achieving better results compared to free hand resections. A planned bone margin from tumour of at least 5 mm was safe for bone resections, but soft tissue margin couldn't be planned when the tumour invaded soft tissues. Moreover, long osteotomies, homogenous bone topology and restricted working spaces reduced accuracy of both techniques, but SN can provide a second check. In urgent cases, SN is more indicated to avoid PSI planning and production time (2-4 weeks), while PSI has the advantage of less intraoperative using time (1-5 min vs 15-65 min). Finally, they deemed similar technical intraoperative complications rate and demanding learning curve. Overall, both techniques present advantages and drawbacks. They must be considered for the optimal choice based on the specific case. In the future, robotic-assisted resections and augmented reality might solve the downsides of PSI and SN becoming the main actors of bone tumour surgery.
Collapse
Affiliation(s)
- Alessandro Bruschi
- Orthopaedic Oncology Unit, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
- Department of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC 3065, Australia
| | - Davide Maria Donati
- Orthopaedic Oncology Unit, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
- Department of Biomedical and Neuromotor Sciences, University of Bologna, 40123 Bologna, Italy
| | - Claudia Di Bella
- Department of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC 3065, Australia
- Department of Surgery, The University of Melbourne, St Vincent's Hospital Melbourne, Fitzroy, VIC 3065, Australia
- VBJS, Victorian Bone and Joint Specialists, 7/55 Victoria Parade, Fitzroy, VIC 3065, Australia
| |
Collapse
|
4
|
Bang H, Park CW, Joung S, Lee HJ, Park IH. Clinical evaluation of a fluoroscopic image-based laser guidance system in bone tumor surgery: A technical note. Med Eng Phys 2023; 120:104056. [PMID: 37838405 DOI: 10.1016/j.medengphy.2023.104056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 09/14/2023] [Accepted: 09/18/2023] [Indexed: 10/16/2023]
Abstract
This study presents a laser guidance system developed to enhance surgical accuracy and reduce radiation exposure in orthopedic surgeries. The system can project the actual position corresponding to the appointed position selected by the surgeon on a fluoroscopic image using a line laser and has laser projection ability to mark the corresponding point using a line laser. The surgeon does not have to perform anatomical marker placement for calibration. Three patients with bone tumors underwent surgeries using the laser guidance system, and the projection accuracy was evaluated by measuring the distance error between the appointed and laser-marking positions. The installation time, including calibration, was also assessed for clinical usability. The average projection accuracy in bone tumor surgery was 2.86 mm, and the average installation time was 7 min. These results demonstrate that the laser guidance system, with a projection error of <3 mm, could be useful in bone tumor surgeries.
Collapse
Affiliation(s)
- Hyunhee Bang
- Medical Device and Robot Institute of Park, Kyungpook National University, 1006 Global plaza, 80 Daehakro, Bukgu, Daegu 41566, South Korea
| | - Chul Woo Park
- Medical Device and Robot Institute of Park, Kyungpook National University, 1006 Global plaza, 80 Daehakro, Bukgu, Daegu 41566, South Korea
| | - Sanghyun Joung
- Medical Device and Robot Institute of Park, Kyungpook National University, 1006 Global plaza, 80 Daehakro, Bukgu, Daegu 41566, South Korea
| | - Hyun-Joo Lee
- Medical Device and Robot Institute of Park, Kyungpook National University, 1006 Global plaza, 80 Daehakro, Bukgu, Daegu 41566, South Korea; Department of Orthopedic surgery, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Dongduk-ro, 130, Jung-gu, Daegu 41944, South Korea.
| | - Il-Hyung Park
- Medical Device and Robot Institute of Park, Kyungpook National University, 1006 Global plaza, 80 Daehakro, Bukgu, Daegu 41566, South Korea; Department of Orthopedic surgery, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Dongduk-ro, 130, Jung-gu, Daegu 41944, South Korea.
| |
Collapse
|
5
|
Shim KW. Medical Applications of 3D Printing and Standardization Issues. Brain Tumor Res Treat 2023; 11:159-165. [PMID: 37550814 PMCID: PMC10409621 DOI: 10.14791/btrt.2023.0001] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 01/13/2023] [Accepted: 01/18/2023] [Indexed: 08/09/2023] Open
Abstract
The three-dimensional (3D) printing itself is not a novel technology, it is more than 30 years old. Stereolithographic (SLA) technology has been used as the first and popular technology for medical application of 3D printing. Since 1991 Radiology and Plastic Surgery have published articles about SLA for rapid prototyping anatomical 3D models. Medical applications of 3D printing have been popularizing and stabilizing so far. Implantable medical devices such as metal or absorbable implants, surgical guide systems, prosthesis and orthosis, and 3D anatomical models for normal or diseased anatomy have been developing and expanding its markets so far. There are many obstacles, such as insurance, authorization as a medical device, and lack of standards technology for further expansion of medical applications. Many technical specifications and guidelines for authorization as medical device have been published by regulatory bodies from many countries. Even though international standards for 3D printing have been developing more and more, there have been few standards for medical application of 3D printing. In this harsh environment academia, company, research institute, regulatory bodies, and government have been doing good job for the development of 3D printing industry.
Collapse
Affiliation(s)
- Kyu Won Shim
- Department of Pediatric Neurosurgery, Severance Children's Hospital, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
6
|
Aiba H, Spazzoli B, Tsukamoto S, Mavrogenis AF, Hermann T, Kimura H, Murakami H, Donati DM, Errani C. Current Concepts in the Resection of Bone Tumors Using a Patient-Specific Three-Dimensional Printed Cutting Guide. Curr Oncol 2023; 30:3859-3870. [PMID: 37185405 PMCID: PMC10136997 DOI: 10.3390/curroncol30040292] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/25/2023] [Accepted: 03/29/2023] [Indexed: 04/01/2023] Open
Abstract
Orthopedic oncology has begun to use three-dimensional-printing technology, which is expected to improve the accuracy of osteotomies, ensure a safe margin, and facilitate precise surgery. However, several difficulties should be considered. Cadaver and clinical studies have reported more accurate osteotomies for bone-tumor resection using patient-specific cutting guides, especially in challenging areas such as the sacrum and pelvis, compared to manual osteotomies. Patient-specific cutting guides can help surgeons achieve resection with negative margins and reduce blood loss and operating time. Furthermore, this patient-specific cutting guide could be combined with more precise reconstruction using patient-specific implants or massive bone allografts. This review provides an overview of the basic technologies used in the production of patient-specific cutting guides and discusses their current status, advantages, and limitations. Moreover, we summarize cadaveric and clinical studies on the use of these guides in orthopedic oncology.
Collapse
Affiliation(s)
- Hisaki Aiba
- Department of Orthopedic Oncology, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
- Department of Orthopedic Surgery, Nagoya City University, Nagoya 467-8601, Aichi, Japan
| | - Benedetta Spazzoli
- Department of Orthopedic Oncology, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Shinji Tsukamoto
- Department of Orthopedic Surgery, Nara Medical University, Kashihara 634-8521, Nara, Japan
| | - Andreas F Mavrogenis
- First Department of Orthopedics, School of Medicine, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Tomas Hermann
- Department of Orthopedic Oncology, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
- Department of Tumors, HTC Hospital, Traumagologico Concepcion, 1580 San Martin, Concepcion 4030000, Chile
| | - Hiroaki Kimura
- Department of Orthopedic Surgery, Nagoya City University, Nagoya 467-8601, Aichi, Japan
| | - Hideki Murakami
- Department of Orthopedic Surgery, Nagoya City University, Nagoya 467-8601, Aichi, Japan
| | - Davide Maria Donati
- Department of Orthopedic Oncology, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Costantino Errani
- Department of Orthopedic Oncology, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| |
Collapse
|
7
|
Rodriguez Colon R, Nayak VV, Parente PEL, Leucht P, Tovar N, Lin CC, Rezzadeh K, Hacquebord JH, Coelho PG, Witek L. The presence of 3D printing in orthopedics: A clinical and material review. J Orthop Res 2023; 41:601-613. [PMID: 35634867 DOI: 10.1002/jor.25388] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 04/13/2022] [Accepted: 05/26/2022] [Indexed: 02/04/2023]
Abstract
The field of additive manufacturing, 3D printing (3DP), has experienced an exponential growth over the past four decades, in part due to increased accessibility. Developments including computer-aided design and manufacturing, incorporation of more versatile materials, and improved printing techniques/equipment have stimulated growth of 3DP technologies within various industries, but most specifically the medical field. Alternatives to metals including ceramics and polymers have been garnering popularity due to their resorbable properties and physiologic similarity to extracellular matrix. 3DP has the capacity to utilize an assortment of materials and printing techniques for a multitude of indications, each with their own associated benefits. Within the field of medicine, advances in medical imaging have facilitated the integration of 3DP. In particular, the field of orthopedics has been one of the earliest medical specialties to implement 3DP. Current indications include education for patients, providers, and trainees, in addition to surgical planning. Moreover, further possibilities within orthopedic surgery continue to be explored, including the development of patient-specific implants. This review aims to highlight the use of current 3DP technology and materials by the orthopedic community, and includes comments on current trends and future direction(s) within the field.
Collapse
Affiliation(s)
- Ricardo Rodriguez Colon
- Icahn School of Medicine at Mount Sinai, New York, New York, USA.,Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, New York, USA
| | - Vasudev Vivekanand Nayak
- Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, New York, USA.,Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, New York, USA
| | - Paulo E L Parente
- Lewis Katz School of Medicine at Temple University, Philadelphia, Pennsylvania, USA.,Department of Orthopedic Surgery, NYU Grossman School of Medicine, New York, New York, USA
| | - Philipp Leucht
- Department of Orthopedic Surgery, NYU Grossman School of Medicine, New York, New York, USA.,Department of Cell Biology, NYU Grossman School of Medicine, New York, New York, USA
| | - Nick Tovar
- Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, New York, USA
| | - Charles C Lin
- Department of Orthopedic Surgery, NYU Grossman School of Medicine, New York, New York, USA
| | - Kevin Rezzadeh
- Department of Orthopedic Surgery, NYU Grossman School of Medicine, New York, New York, USA
| | - Jacques H Hacquebord
- Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, New York, USA.,Department of Orthopedic Surgery, NYU Grossman School of Medicine, New York, New York, USA
| | - Paulo G Coelho
- Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, New York, USA.,Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, New York, USA.,Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, New York, USA
| | - Lukasz Witek
- Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, New York, USA.,Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, New York, USA
| |
Collapse
|
8
|
Patient-Specific Instruments for Forearm Sarcoma Resection and Allograft Reconstruction in Children: Results in 4 Cases. Sarcoma 2022; 2022:7005629. [PMID: 36353598 PMCID: PMC9640240 DOI: 10.1155/2022/7005629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 08/18/2022] [Accepted: 10/17/2022] [Indexed: 12/02/2022] Open
Abstract
For pediatric malignant bone tumors located in the limbs, limb salvage surgery is the gold standard, but it requires adequate resection margins to avoid local recurrence. Primitive bone sarcomas of the forearm (radius or ulna) are very rare and the reconstruction remains challenging. We describe a method to ensure minimal but adequate resection bone margins with precision in four consecutive patients with primitive bone sarcomas of the forearm. During the preoperative planning, magnetic resonance imaging (MRI) was used to delineate the tumor and the tumor volume was transferred to computerized tomography (CT) by image fusion. A patient-specific instrument (PSI) was manufactured by 3D printing to allow the surgeon to perform the surgical cuts precisely according to the preoperative planning. The first PSI was used for the resection of the tumor, which adopted a unique position at the bony surface. A second PSI was intended for the cutting of the bone allograft so that it fitted perfectly with the bone defect. In all four cases, the safe margin obtained into the bone was free of tumor (R0: microscopically margin-negative resection). The functional result was very good in all four patients. This limb salvage surgical technique can be applied in forearm bone sarcoma and improves surgical precision while maintaining satisfactory local tumor control. It can also reduce the surgical time and allow a stable osteosynthesis.
Collapse
|
9
|
Wong KC, Sun YE, Kumta SM. Review and Future/Potential Application of Mixed Reality Technology in Orthopaedic Oncology. Orthop Res Rev 2022; 14:169-186. [PMID: 35601186 PMCID: PMC9121991 DOI: 10.2147/orr.s360933] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 04/26/2022] [Indexed: 11/23/2022] Open
Abstract
In orthopaedic oncology, surgical planning and intraoperative execution errors may result in positive tumor resection margins that increase the risk of local recurrence and adversely affect patients’ survival. Computer navigation and 3D-printed resection guides have been reported to address surgical inaccuracy by replicating the surgical plans in complex cases. However, limitations include surgeons’ attention shift from the operative field to view the navigation monitor and expensive navigation facilities in computer navigation surgery. Practical concerns are lacking real-time visual feedback of preoperative images and the lead-time in manufacturing 3D-printed objects. Mixed Reality (MR) is a technology of merging real and virtual worlds to produce new environments with enhanced visualizations, where physical and digital objects coexist and allow users to interact with both in real-time. The unique MR features of enhanced medical images visualization and interaction with holograms allow surgeons real-time and on-demand medical information and remote assistance in their immediate working environment. Early application of MR technology has been reported in surgical procedures. Its role is unclear in orthopaedic oncology. This review aims to provide orthopaedic tumor surgeons with up-to-date knowledge of the emerging MR technology. The paper presents its essential features and clinical workflow, reviews the current literature and potential clinical applications, and discusses the limitations and future development in orthopaedic oncology. The emerging MR technology adds a new dimension to digital assistive tools with a more accessible and less costly alternative in orthopaedic oncology. The MR head-mounted display and hand-free control may achieve clinical point-of-care inside or outside the operating room and improve service efficiency and patient safety. However, lacking an accurate hologram-to-patient matching, an MR platform dedicated to orthopaedic oncology, and clinical results may hinder its wide adoption. Industry-academic partnerships are essential to advance the technology with its clinical role determined through future clinical studies. ![]()
Point your SmartPhone at the code above. If you have a QR code reader the video abstract will appear. Or use: https://youtu.be/t4hl_Anh_kM
Collapse
Affiliation(s)
- Kwok Chuen Wong
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, the Chinese University of Hong Kong, Hong Kong Special Administrative Region, People’s Republic of China
- Correspondence: Kwok Chuen Wong, Department of Orthopaedics and Traumatology, Prince of Wales Hospital, the Chinese University of Hong Kong, Hong Kong Special Administrative Region, People’s Republic of China, Email
| | - Yan Edgar Sun
- New Territories, Hong Kong Special Administrative Region, People’s Republic of China
| | - Shekhar Madhukar Kumta
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, the Chinese University of Hong Kong, Hong Kong Special Administrative Region, People’s Republic of China
| |
Collapse
|
10
|
De Paolis M, Sambri A, Zucchini R, Frisoni T, Spazzoli B, Taddei F, Donati DM. Custom-made 3D-Printed Prosthesis in Periacetabular Resections Through a Novel Ileo-adductor Approach. Orthopedics 2022; 45:e110-e114. [PMID: 34978936 DOI: 10.3928/01477447-20211227-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Resection of sarcomas around the acetabulum presents major challenges. The resulting bone effect can be reconstructed with personalized custom-made prostheses. Patient-specific instruments (PSIs) have been demonstrated to be of added value for bone-cutting accuracy, and they may improve pelvic surgery. The authors describe a novel ileo-adductor approach for pelvic tumor surgery and report the preliminary results of 5 reconstructions using custom 3D-printed prostheses associated with PSI surgical guides. This combined technique allows an optimal restoration of the anatomy with reduced surgical time and reduced postoperative complications such as infections and wound healing problems. [Orthopedics. 2022;45(2):e110-e114.].
Collapse
|
11
|
Kermavnar T, Shannon A, O'Sullivan LW. The application of additive manufacturing / 3D printing in ergonomic aspects of product design: A systematic review. APPLIED ERGONOMICS 2021; 97:103528. [PMID: 34256321 DOI: 10.1016/j.apergo.2021.103528] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 05/24/2021] [Accepted: 07/01/2021] [Indexed: 06/13/2023]
Abstract
Additive Manufacturing (AM) facilitates product personalization and iterative design, which makes it an ideal technology for ergonomic product development. In this study, a systematic review was conducted of the literature regarding the use of AM in ergonomic-product design, and methodological aspects of the studies were analyzed. A literature search was performed using the keywords "3D print*," "additive manufacturing," "ergonomic*" and "human factors". Included were studies reporting the use of AM specifically in ergonomic design of products/prototypes including the detailing of an ergonomic testing methodology used for evaluation. Forty studies were identified pertaining to the fields of medicine, assistive technology, wearable technology, hand tools, testing devices and others. The most commonly used technology was fused deposition modeling with polylactic acid, but the overall preferred material was acrylonitrile butadiene styrene. Various combinations of objective/subjective and qualitative/quantitative product evaluation methods were used. Based on the findings, recommendations were developed to facilitate the choice of most suitable AM technologies and materials for specific applications in ergonomics.
Collapse
Affiliation(s)
- Tjaša Kermavnar
- School of Design, Confirm Smart Manufacturing Centre and Health Research Institute, University of Limerick, Limerick, Ireland
| | - Alice Shannon
- School of Design, University of Limerick, Limerick, Ireland
| | - Leonard W O'Sullivan
- School of Design, Confirm Smart Manufacturing Centre and Health Research Institute, University of Limerick, Limerick, Ireland.
| |
Collapse
|
12
|
Zakani S, Chapman C, Saule A, Cooper A, Mulpuri K, Wilson DR. Computer-assisted subcapital correction osteotomy in slipped capital femoral epiphysis using individualized drill templates. 3D Print Med 2021; 7:18. [PMID: 34228206 PMCID: PMC8259369 DOI: 10.1186/s41205-021-00108-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 06/14/2021] [Indexed: 11/19/2022] Open
Abstract
Background Subcapital osteotomy by means of surgical hip dislocation is a treatment approach offered for moderate-to-severe cases of Slipped Capital Femoral Epiphysis (SCFE). This procedure is demanding, highly dependent on the surgeon’s experience, and requires considerable radiation exposure for monitoring and securing the spatial alignment of the femoral head. We propose the use of individualized drill guides as an accurate method for placing K-wires during subcapital correction osteotomies in SCFE patients. Methods Five CT scans of the hip joint from otherwise healthy patients with moderate-to-severe SCFE were selected (ages 11–14). Three dimensional models of each patient’s femur were reconstructed by manual segmentation and physically replicated using additive manufacturing techniques. Five orthopaedic surgeons virtually identified the optimal entry point and direction of the two threaded wires for each case. 3D printed drill guides were designed specific to each surgical plan, with one side shaped to fit the patient’s bone and the other side containing holes to guide the surgical drill. Each surgeon performed three guided (using the drill guides) and three conventional (freehand) simulated procedures on each case. Each femur model was laser scanned and digitally matched to the preoperative model for evaluation of entry points and wire angulations. We compared wire entry point, wire angulation, procedure time and number of x-rays between guided and freehand simulated surgeries. Results The guided group (1.4 ± 0.9 mm; 2.5° ± 1.4°) was significantly more accurate than the freehand group (5.8 ± 3.2 mm; 5.3° ± 4.4°) for wire entry location and angulation (p < 0.001). Guided surgeries required significantly less drilling time and intraoperative x-rays (90.5 ± 42.2 s, 3 ± 1 scans) compared to the conventional surgeries (246.8 ± 122.1 s, 14 ± 5 scans) (p < 0.001). Conclusions We conclude that CT-based preoperative planning and intraoperative navigation using individualized drill guides allow for improved accuracy of wires, reduced operative time and less radiation exposure in simulated hips. Clinical relevance This preliminary study shows promising results, suggesting potential direct benefits to SCFE patients by necessitating less time under anesthesia and less intra-operative radiation exposure to patients, and increasing surgical accuracy.
Collapse
Affiliation(s)
- Sima Zakani
- Department of Pediatrics, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Christopher Chapman
- Department of Orthopaedic Surgery, SUNY Downstate Medical Center, Brooklyn, NY, USA
| | - Adam Saule
- Department of Mechanical Engineering, Dalhousie University, Halifax, NS, Canada
| | - Anthony Cooper
- Department of Orthopaedic Surgery, BC Children's Hospital, Vancouver, BC, Canada.,Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Kishore Mulpuri
- Department of Orthopaedic Surgery, BC Children's Hospital, Vancouver, BC, Canada. .,Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada.
| | - David R Wilson
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
13
|
Daoud GE, Pezzutti DL, Dolatowski CJ, Carrau RL, Pancake M, Herderick E, VanKoevering KK. Establishing a point-of-care additive manufacturing workflow for clinical use. JOURNAL OF MATERIALS RESEARCH 2021; 36:3761-3780. [PMID: 34248272 PMCID: PMC8259775 DOI: 10.1557/s43578-021-00270-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
Additive manufacturing, or 3-Dimensional (3-D) Printing, is built with technology that utilizes layering techniques to build 3-D structures. Today, its use in medicine includes tissue and organ engineering, creation of prosthetics, the manufacturing of anatomical models for preoperative planning, education with high-fidelity simulations, and the production of surgical guides. Traditionally, these 3-D prints have been manufactured by commercial vendors. However, there are various limitations in the adaptability of these vendors to program-specific needs. Therefore, the implementation of a point-of-care in-house 3-D modeling and printing workflow that allows for customization of 3-D model production is desired. In this manuscript, we detail the process of additive manufacturing within the scope of medicine, focusing on the individual components to create a centralized in-house point-of-care manufacturing workflow. Finally, we highlight a myriad of clinical examples to demonstrate the impact that additive manufacturing brings to the field of medicine.
Collapse
Affiliation(s)
| | | | | | - Ricardo L. Carrau
- The Ohio State University College of Medicine, Columbus, OH USA
- The Ohio State University James Comprehensive Cancer Center, Columbus, OH 43210 USA
- Department of Otolaryngology, The Ohio State University, Columbus, OH USA
| | - Mary Pancake
- Department of Engineering, The Ohio State University, Columbus, OH USA
| | - Edward Herderick
- Department of Engineering, The Ohio State University, Columbus, OH USA
| | - Kyle K. VanKoevering
- The Ohio State University College of Medicine, Columbus, OH USA
- The Ohio State University James Comprehensive Cancer Center, Columbus, OH 43210 USA
- Department of Otolaryngology, The Ohio State University, Columbus, OH USA
| |
Collapse
|
14
|
Wong KC, Sze LKY, Kumta SM. Complex joint-preserving bone tumor resection and reconstruction using computer navigation and 3D-printed patient-specific guides: A technical note of three cases. J Orthop Translat 2021; 29:152-162. [PMID: 34249613 PMCID: PMC8241897 DOI: 10.1016/j.jot.2021.05.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 05/30/2021] [Accepted: 05/31/2021] [Indexed: 02/07/2023] Open
Abstract
In selected extremity bone sarcomas, joint-preserving surgery retains the natural joints and nearby ligaments with a better function than in traditional joint-sacrificing surgery. Geometric multiplanar osteotomies around bone sarcomas were reported with the advantage of preserving more host bone. However, the complex surgical planning translation to the operating room is challenging. Using both Computer Navigation and Patient-Specific Guide may combine each technique's key advantage in assisting complex bone tumor resections. Computer Navigation provides the visual image feedback of the pathological information and validates the correct placement of Patient-Specific Guide that enables accurate, guided bone resections. We first described the digital workflow and the use of both computer navigation and patient-specific guides (NAVIG) to assist the multiplanar osteotomies in three extremity bone sarcoma patients who underwent joint-preserving bone tumor resections and reconstruction with patient-specific implants. The NAVIG technique verified the correct placement of patient-specific guides that enabled precise osteotomies and well-fitted patient-specific implants. The mean maximum deviation errors of the nine achieved bone resections were 1.64 ± 0.35 mm (95% CI 1.29 to 1.99). The histological examination of the tumor specimens showed negative resection margin. At the mean follow-up of 55 months (40–67), no local recurrence was noted. There was no implant loosening that needed revision. The mean MSTS score was 29 (28–30) out of 30 with the mean knee flexion of 140° (130°–150°). The excellent surgical accuracy and limb function suggested that the NAVIG technique might replicate the surgical planning of complex bone sarcoma resections by combining the strength of both Computer Navigation and Patient-Specific Guide. The patient-specific approach may translate into clinical benefits. The translational potential of this article: The newly described technique enhances surgeons’ capability in performing complex joint-preserving surgery in bone sarcoma that is difficult to be achieved by the traditional method. The high precision and accuracy may translate into superior clinical outcomes.
Collapse
Affiliation(s)
- Kwok Chuen Wong
- Orthopaedic Oncology, Department of Orthopaedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Louis Kwan Yik Sze
- Orthopaedic Oncology, Department of Orthopaedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Shekhar Madhukar Kumta
- Orthopaedic Oncology, Department of Orthopaedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
15
|
Effectiveness Assessment of CAD Simulation in Complex Orthopedic Surgery Practices. Symmetry (Basel) 2021. [DOI: 10.3390/sym13050850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
This experimental study defines the usage of a computer-aided surgical simulation process that is effective, safe, user-friendly, and low-cost, that achieves a detailed and realistic representation of the anatomical region of interest. The chosen tools for this purpose are state-of-the-art Computer Aided Design (CAD) software for mechanical design, and are the fundamental application dedicated to parametric modeling. These tools support different work environments, each one is for a specific type of modeling, and they allow the simulation of surgery. The result will be a faithful representation of the anatomical part both before and after the surgical procedure, screening all the intermediate phases. The doctor will assess different lines of action according to the results, then he will communicate them to the engineer who, consequently, will correct the antisymmetric issue and regenerate the model. Exact measurements of the mutual positions of the various components, skeletal and synthetic, can be achieved; all the osteosynthesis tools, necessary for the surgeon, can be included in the project according to different types of fracture to perfectly match the morphology of the bone to be treated. The method has been tested on seven clinical cases of different complexity and nature and the results of the simulations have been found to be of great effectiveness in the phase of diagnosis and of preoperative planning for the doctors and surgeons; therefore, allowing a lower risk medical operation with a better outcome. This work delivers experimental results in line with theoretical research findings in detail; moreover, full experimental and/or methodical details are provided, so that outcomes could be obtained.
Collapse
|
16
|
Gursan O, Celtik M, Yanik B, Husemoglu RB, Havitcioglu H. Three-Dimensionally-Printed Joint-Preserving Prosthetic Reconstruction of Massive Bone Defects After Malignant Tumor Resection of the Proximal Tibia. Cureus 2021; 13:e13784. [PMID: 33842159 PMCID: PMC8032040 DOI: 10.7759/cureus.13784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Joint-preserving prosthetic reconstruction for massive bone defects has the potential to be a new and revolutionary treatment option. In this paper, we discuss the case of a 30-year-old female patient who presented with pain and swelling around the knee for three months. The patient underwent this procedure. Postoperative patient satisfaction, pain scores, and range of motion results were found to be promising. We believe that this method has the potential to be the next stage in the quest for better treatment options for this condition.
Collapse
Affiliation(s)
- Onur Gursan
- Department of Orthopedics and Traumatology, Dokuz Eylül University, Izmir, TUR
| | - Mustafa Celtik
- Department of Orthopedics and Traumatology, Dokuz Eylül University, Izmir, TUR
| | - Berkay Yanik
- Department of Orthopedics and Traumatology, Dokuz Eylül University, Izmir, TUR
| | | | - Hasan Havitcioglu
- Department of Orthopedics and Traumatology, Dokuz Eylül University, Izmir, TUR
| |
Collapse
|
17
|
Computer Navigation and 3D Printing in the Surgical Management of Bone Sarcoma. Cells 2021; 10:cells10020195. [PMID: 33498287 PMCID: PMC7909290 DOI: 10.3390/cells10020195] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/17/2021] [Accepted: 01/18/2021] [Indexed: 12/16/2022] Open
Abstract
The long-term outcomes of osteosarcoma have improved; however, patients with metastases, recurrence or axial disease continue to have a poor prognosis. Computer navigation in surgery is becoming ever more commonplace, and the proposed advantages, including precision during surgery, is particularly applicable to the field of orthopaedic oncology and challenging areas such as the axial skeleton. Within this article, we provide an overview of the field of computer navigation and computer-assisted tumour surgery (CATS), in particular its relevance to the surgical management of osteosarcoma.
Collapse
|
18
|
A New Generation of Bio-Composite Thermoplastic Filaments for a More Sustainable Design of Parts Manufactured by FDM. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10175852] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The most recent developments of Fused Deposition Modelling (FDM) techniques are moving the application of Additive Manufacturing (AM) technologies toward new areas of investigation such as the biomedical, aerospace, and marine engineering in addition to the more consolidated industrial and civil fields. Some specific characteristics are required for the components designed for peculiar applications, such as complex geometries, lightweight, and high strength as well as breathability and aesthetic appearance specifically in the biomedical field. All these design specifications could be potentially satisfied by manufacturing with 3D printing techniques. Moreover, the development of purpose-dedicated filaments can be considered a key factor to successfully meet all the requirements. In this paper, fabrication and applications of five new thermoplastic materials with fillers are described and analyzed. They are organic bio-plastic compounds made of polylactic acid (PLA) and organic by-products. The growing interest in these new composite materials reinforced with organic by-products is due to the reduction of production management costs and their low environmental impact. In this study, the production workflow has been set up and described in detail. The main properties of these new thermoplastic materials have been analyzed with a major emphasis on strength, lightweight, and surface finish. The analysis showed that these materials can be particularly suitable for biomedical applications. Therefore, two different biomedical devices were selected and relative prototypes were manufactured with one of the analyzed thermoplastic materials. The feasibility, benefits, and performance of the thermoplastic material considered for these applications were successfully assessed.
Collapse
|
19
|
Xu M, Wang Z, Yu XC, Lin JH, Hu YC. Guideline for Limb-Salvage Treatment of Osteosarcoma. Orthop Surg 2020; 12:1021-1029. [PMID: 32633103 PMCID: PMC7454155 DOI: 10.1111/os.12702] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 04/20/2020] [Indexed: 12/26/2022] Open
Abstract
Osteosarcoma is the most common primary malignant bone tumor, occurring mainly in children and adolescents, and the limbs are the main affected sites. At present, limb‐salvage treatment is considered as an effective basic standard treatment for osteosarcoma of the limb. China has a vast territory, but the development of technology is not balanced,which requires sufficient theoretical coverage, strong technical guidance and the application of limb‐salvage treatment guidelines to the treatment of osteosarcoma. Therefore, to standardize and promote the development of limb‐salvage surgery technology and improve the success rate of limb‐salvage treatment, this guide systematically introduces limb‐salvage techniques for the treatment of patients with limb osteosarcoma through definition of limb‐salvage treatment, surgical methods, efficacy evaluation, postoperative treatment and prevention of complications, rehabilitation guidance, and follow‐up advice.
Collapse
Affiliation(s)
- Ming Xu
- Department of Orthopedics, The 960th Hospital of PLA, Jinan, China
| | - Zhen Wang
- Department of Orthopedics, Xi-jing Hospital, Air Force Military Medical University, Xi'an, China
| | - Xiu-Chun Yu
- Department of Orthopedics, The 960th Hospital of PLA, Jinan, China
| | - Jian-Hua Lin
- Department of Orthopedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Yong-Cheng Hu
- Department of Bone Oncology, Tianjin hospital, Tianjin, China
| |
Collapse
|
20
|
Montgomery SJ, Kooner SS, Ludwig TE, Schneider PS. Impact of 3D Printed Calcaneal Models on Fracture Understanding and Confidence in Orthopedic Surgery Residents. JOURNAL OF SURGICAL EDUCATION 2020; 77:472-478. [PMID: 32033916 DOI: 10.1016/j.jsurg.2019.10.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 08/23/2019] [Accepted: 10/03/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE To determine if three-dimensionally printed (3Dp) fracture models can improve orthopedic trainee education. DESIGN A prospective comparison study of orthopedic trainees and attending surgeons was performed, where a range of calcaneal fractures were used for creating anonymized 3Dp models. Study participants rotated through workstations viewing computed tomography images and either a digital 3D volume rendering or 3Dp model of the fractured calcaneus. Diagnosis, time for evaluation, confidence of fracture understanding, perceived model accuracy, and proposed treatment were compared using a standardized questionnaire. PARTICIPANTS Sixteen resident trainees and 5 attending surgeons participated in this study. Attending surgeons were required to have fellowship training in trauma or foot and ankle surgery and manage calcaneal fractures as part of their current practice. RESULTS Junior residents had the slowest time of assessment (mean = 121 ± 54 seconds) and lowest percentage of correct diagnoses (69%), although these findings did not reach significance compared to the other residency years. Residents displayed higher levels of confidence in fracture understanding with increasing residency year of training (p < 0.0001), and this confidence was greater for cases that included a 3Dp model (p < 0.03). Perceived accuracy of cases with 3Dp models was significantly higher than cases without 3Dp models (7.0 vs 5.5 p < 0.001). CONCLUSIONS This study found that 3Dp models increase the perceived accuracy of fracture assessment, though no statistically significant improvement in diagnostic accuracy was observed. The 3Dp models did improve trainee confidence, although this effect diminished with increasing residency year. In orthopedic residency training programs, 3Dp models of complex fractures can be a valuable educational tool, especially for junior trainees.
Collapse
|
21
|
Integration of a Three-Dimensional-Printed Titanium Implant in Human Tissues: Case Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10020553] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
A titanium alloy implant of appropriate pore size can potentially enhance osseointegration and soft tissue integration. However, the human clinical application of such implants has not been reported. Here, we present a case of limb salvage surgery for a bone tumor using customized three-dimensional (3D)-printed Ti6Al4V radius and ulna implants. The patient presented with local recurrence at the proximal junction of the ulna and underwent a re-wide excision. Single forearm bone surgery was performed using another 3D-printed implant after resection of the recurrent tumor with an ulnar implant. Host osseointegration and soft tissue integration of the retrieved implant were quantified through histological evaluation. The total tissue integration rates of the implant at the proximal and distal bone junctions were 45.96% and 15.03%, respectively. The mesh structure enhanced bone integration by up to 10.81% in the proximal and by up to 8.91% in the distal bone junction. Furthermore, the soft tissue adhesion rates of the implant shaft were 59.50% and 50.26% in the axial and longitudinal cuts, respectively. No area was left unoccupied throughout the shaft of the implant. Overall, these results indicate that the 3D-printed Ti6Al4V titanium alloy implant with a rough surface has considerable tissue integration ability.
Collapse
|
22
|
Combined Application of Modified Three-Dimensional Printed Anatomic Templates and Customized Cutting Blocks in Pelvic Reconstruction After Pelvic Tumor Resection. J Arthroplasty 2019; 34:338-345.e1. [PMID: 30497901 DOI: 10.1016/j.arth.2018.10.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 09/20/2018] [Accepted: 10/02/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Common three-dimensional (3D)-printed anatomic templates have generally been used to reconstruct the pelvis after zone II and III borderline pelvic tumor resection. However, gradual increases in postoperative implant complications and the tumor recurrence rate have been observed. This study aimed to introduce the innovative application of a modified 3D-printed anatomic template with a customized cutting block for pelvic reconstruction and to comparatively analyze the common and modified 3D-printed anatomic templates. METHODS A total of 38 patients were included in this study and were allocated to 2 groups (19 patients/group). Group A received innovative therapy, and Group B received traditional therapy. All patients were questioned in detail about age, location, and duration of the mass and associated symptoms, and routine blood tests, such as serological tests, were administered. RESULTS We found that the modified 3D-printed anatomic template with a customized cutting block resulted in a shorter operating time, smaller bleeding loss, and simpler operation than the common 3D-printed anatomic template. Additionally, the tumor recurrence rate was lower and the accuracy of tumor resection was much greater for the modified 3D-printed anatomic template with a customized cutting block. However, compared with the traditional therapy, the innovative therapy had a significantly higher rate of implant loosening. CONCLUSION The innovative therapy can increase surgical safety and reduce recurrence after tumor resection relative to the traditional therapy. Additionally, the innovative therapy reconstructs the pelvis of zone III to improve the quality of patient life. However, the innovative therapy with implant loosening should be improved.
Collapse
|
23
|
Park JW, Kang HG, Lim KM, Park DW, Kim JH, Kim HS. Bone tumor resection guide using three-dimensional printing for limb salvage surgery. J Surg Oncol 2018; 118:898-905. [PMID: 30261096 DOI: 10.1002/jso.25236] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 08/20/2018] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND OBJECTIVES The three-dimensional (3D)-printed bone tumor resection guide can be personalized for a specific patient and utilized for bone tumor surgery. It is noninvasive, eidetic, and easy to use. We aimed to categorize the use of the 3D-printed guide and establish in vivo accuracy data. METHODS We retrospectively reviewed 12 patients, who underwent limb salvage surgery using the 3D-printed guide at a single institution. To confirm the achievement of a safe bone margin, we compared the actual and planned distances between the cutting surface and tumor, which were reported in the final pathological report and measured from the same virtual cutting plane using graphical data of the cutting guide design, respectively. RESULTS The use of the 3D-printed guide was categorized as follows: (a) wide excision only, (b) wide excision and biological reconstruction with a structural bone allograft shaped in accordance with the 3D-printed guide, and (c) wide excision and reconstruction with a 3D-printed personalized implant. The maximal cutting error was 3 mm. CONCLUSIONS The 3D-printed resection guide is easy to use and shows promise in the field of orthopedic oncology, with its application in bone tumor resection and reconstruction with a structural bone allograft or 3D-printed implant.
Collapse
Affiliation(s)
- Jong Woong Park
- Orthopaedic Oncology Clinic, National Cancer Center, Goyang, Korea
| | - Hyun Guy Kang
- Orthopaedic Oncology Clinic, National Cancer Center, Goyang, Korea.,Innovative Medical Engineering and Technology, National Cancer Center, Goyang, Korea
| | - Kwun Mook Lim
- Department of Mechanical Engineering, Korea National University of Transportation, Chungju-si, Korea
| | - Dae Woo Park
- Innovative Medical Engineering and Technology, National Cancer Center, Goyang, Korea
| | - June Hyuk Kim
- Orthopaedic Oncology Clinic, National Cancer Center, Goyang, Korea
| | - Han Soo Kim
- Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
24
|
Gao T, Rivlin M, Abraham JA. Three-dimensional Printing Technology and Role for Custom Implants in Orthopedic Oncology. Tech Orthop 2018. [DOI: 10.1097/bto.0000000000000292] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Thadani VN, Riaz MJ, Singh G. The evolution of three-dimensional technology in musculoskeletal oncology. J Clin Orthop Trauma 2018; 9:269-274. [PMID: 30202160 PMCID: PMC6128801 DOI: 10.1016/j.jcot.2018.07.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 07/21/2018] [Indexed: 12/25/2022] Open
Abstract
Musculoskeletal tumours pose considerable challenges for the orthopaedic surgeon during pre-operative planning, resection and reconstruction. Improvements in imaging technology have improved the diagnostic process of these tumours. Despite this, studies have highlighted the difficulties in achieving consistent resection free margins especially in tumours of the pelvis and spine when using conventional methods. Three-dimensional technology - three-dimensional printing and navigation technology - while relatively new, may have the potential to prove useful in the musculoskeletal tumour surgeon's arsenal. Three-dimensional printing (3DP) allows the production of objects by adding material layer by layer rather than subtraction from raw materials as performed conventionally. High resolution imaging, computer tomography (CT) and magnetic resonance imaging (MRI), are used to print highly complex and accurate items. Powder-based printing, vat polymerization-based printing and droplet-based printing are the common 3DP technologies applied. 3DP has been utilized pre-operatively in surgical planning and intra-operatively for patient specific instruments and custom made prosthesis. Pre-operative 3DP models transfer information to the surgeon in a concise yet exhaustive manner. Patient specific instruments are customized 3DP instruments utilized with the intention to easily replicate surgical plans. Complex musculoskeletal tumours pose reconstructive challenges and standard implants are often unable to reconstruct defects satisfactorily. The ability to use custom materials and tailor the pore size, elastic modulus and porosity of the 3DP prosthesis to be comparable to the patient's bone allows for a potential patient-specific prosthesis with unique incorporation and longevity properties. Similarly, navigation technology utilizes CT or MRI images to provides surgeons with real time intraoperative three-dimensional calibration of instruments. It has been shown to potentially allow surgeons to perform more accurate resections. These technological advancements have the potential to greatly impact the management of musculoskeletal tumours. 3D planning models, patient-specific instruments and customized 3DP implants and navigation should not be thought of as separate, but rather, patient-specific adaptation of relevant modes of application should be selected on a case-by-case basis when taking all unique factors of each case into consideration.
Collapse
Affiliation(s)
| | | | - Gurpal Singh
- University Orthopaedics, Hand and Reconstructive Microsurgery (UOHC), National University Health System, Singapore
| |
Collapse
|
26
|
Lim SH, Kim YH, Kim MK, Nam W, Kang SH. Validation of a fibula graft cutting guide for mandibular reconstruction: experiment with rapid prototyping mandible model. Comput Assist Surg (Abingdon) 2018; 21:9-17. [PMID: 27973958 DOI: 10.3109/24699322.2016.1167245] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE We examined whether cutting a fibula graft with a surgical guide template, prepared with computer-aided design/computer-aided manufacturing (CAD/CAM), would improve the precision and accuracy of mandibular reconstruction. METHODS Thirty mandibular rapid prototype (RP) models were allocated to experimental (N = 15) and control (N = 15) groups. Thirty identical fibular RP models were assigned randomly, 15 to each group. For reference, we prepared a reconstructed mandibular RP model with a three-dimensional printer, based on surgical simulation. In the experimental group, a stereolithography (STL) surgical guide template, based on simulation, was used for cutting the fibula graft. In the control group, the fibula graft was cut manually, with reference to the reconstructed RP mandible model. The mandibular reconstructions were compared to the surgical simulation, and errors were calculated for both the STL surgical guide and the manual methods. RESULTS The average differences in three-dimensional, minimum distances between the reconstruction and simulation were 9.87 ± 6.32 mm (mean ± SD) for the STL surgical guide method and 14.76 ± 10.34 mm (mean ± SD) for the manual method. DISCUSSION The STL surgical guide method incurred less error than the manual method in mandibular reconstruction. A fibula cutting guide improved the precision of reconstructing the mandible with a fibula graft.
Collapse
Affiliation(s)
- Se-Ho Lim
- a Department of Oral and Maxillofacial Surgery , National Health Insurance Service Ilsan Hospital , Goyang , Republic of Korea
| | - Yeon-Ho Kim
- a Department of Oral and Maxillofacial Surgery , National Health Insurance Service Ilsan Hospital , Goyang , Republic of Korea
| | - Moon-Key Kim
- a Department of Oral and Maxillofacial Surgery , National Health Insurance Service Ilsan Hospital , Goyang , Republic of Korea.,b Department of Oral and Maxillofacial Surgery , College of Dentistry, Yonsei University , Seoul , Republic of Korea
| | - Woong Nam
- b Department of Oral and Maxillofacial Surgery , College of Dentistry, Yonsei University , Seoul , Republic of Korea
| | - Sang-Hoon Kang
- a Department of Oral and Maxillofacial Surgery , National Health Insurance Service Ilsan Hospital , Goyang , Republic of Korea.,b Department of Oral and Maxillofacial Surgery , College of Dentistry, Yonsei University , Seoul , Republic of Korea
| |
Collapse
|
27
|
Harrison DJ, Geller DS, Gill JD, Lewis VO, Gorlick R. Current and future therapeutic approaches for osteosarcoma. Expert Rev Anticancer Ther 2017; 18:39-50. [PMID: 29210294 DOI: 10.1080/14737140.2018.1413939] [Citation(s) in RCA: 488] [Impact Index Per Article: 69.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
INTRODUCTION Current treatment of osteosarcoma includes surgical resection of all gross disease in conjunction with systemic chemotherapy to control micro-metastatic disease. This yields a 5-year event free survival (EFS) of approximately 70% for patients with localized osteosarcoma while patients with metastatic or recurrent disease fare poorly with overall survival rates of less than 20%. Areas covered: This review outlines the current and future approach towards the treatment of osteosarcoma. A literature search was performed utilizing PubMed. Several recent clinical trials are reviewed in detail, as is innovative research evaluating novel agents and surgical techniques which hold promise. Expert commentary: The outcome for patients with osteosarcoma has not changed in several decades. This plateau in survival rates highlights the need for a novel approach towards research. There remains a great deal of interest in utilizing the very high risk population of recurrent osteosarcoma patients to rapidly and sequentially evaluate novel agents to determine if any of these agents hold promise. Several phase II studies are ongoing or in development that offer hope based on intriguing preclinical data. Furthermore, initiatives in obtaining specimens to further explore the genetic and immunological profile behind osteosarcoma will be essential towards identifying novel pathways and targets to exploit.
Collapse
Affiliation(s)
- Douglas J Harrison
- a Department of Pediatrics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - David S Geller
- b Montefiore Medical Center and the Children's Hospital at Montefiore , The University Hospital for Albert Einstein College of Medicine , Bronx , NY , USA
| | - Jonathan D Gill
- a Department of Pediatrics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - Valerae O Lewis
- a Department of Pediatrics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - Richard Gorlick
- a Department of Pediatrics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| |
Collapse
|
28
|
Yang Y, Han L, He Z, Li X, Yang S, Yang J, Zhang Y, Li D, Yang Y, Yang Z. Advances in limb salvage treatment of osteosarcoma. J Bone Oncol 2017; 10:36-40. [PMID: 29296558 PMCID: PMC5739147 DOI: 10.1016/j.jbo.2017.11.005] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Accepted: 11/23/2017] [Indexed: 12/15/2022] Open
Abstract
Osteosarcoma is the most common primary malignant bone tumor; its standard treatment includes neoadjuvant chemotherapy combined with surgery. Neoadjuvant chemotherapy has significantly improved the 5-year survival and limb salvage rates in osteosarcoma since the 1870s. The survival rate of patients with limb salvage was not inferior to that of amputees, and therefore, limb salvage has become the main surgical option for patients with osteosarcoma. The 5-year survival rate for osteosarcoma has plateaued. However, new advances in limb salvage therapy in osteosarcoma, including adjuvant chemotherapy, ablation techniques, bone transport techniques, and computer navigation techniques, are now available. This report summarizes the recent advances in limb salvage therapy for osteosarcoma over the past decade.
Collapse
Affiliation(s)
- Yichun Yang
- Department of Medical, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, No 16, Jichang Road, Baiyun District, Guangzhou, Guangdong 510405, People's Republic of China
| | - Lei Han
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Zewei He
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Xiaojuan Li
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Suping Yang
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Jifei Yang
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Ya Zhang
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Dongqi Li
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Yihaho Yang
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| | - Zuozhang Yang
- Bone and Soft Tissue Tumors Research Center of Yunnan Province, Department of Orthopaedics, The Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan 650118, People's Republic of China
| |
Collapse
|
29
|
3D printed personalized titanium plates improve clinical outcome in microwave ablation of bone tumors around the knee. Sci Rep 2017; 7:7626. [PMID: 28790331 PMCID: PMC5548746 DOI: 10.1038/s41598-017-07243-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Accepted: 06/22/2017] [Indexed: 12/14/2022] Open
Abstract
Microwave ablation has been widely accepted in treating bone tumor. However, its procedure is time-consuming and usually results in postoperative fractures. To solve this problem, we designed and fabricated titanium plates customized to the patients’ bone structures. The personalized titanium plates were then used for fixation after the removal of tumorous tissue. Specifically, 3D models of tumor-bearing bone segments were constructed by using computed tomography (CT) and magnetic resonance imaging (MRI). The 3D models were used to design the personalized titanium plates. The plate model was transferred into a numerical control machine for manufacturing the personalized titanium plates by 3D printing. The plates were then surgically implanted for reconstruction assistance following microwave-induced hyperthermia to remove the bone tumor. Implementation parameters and knee functions were then evaluated. No postoperative fractures, implant failures or loosening problems occurred; mean Musculoskeletal Tumor Society score was 27.17 from the latest follow-up. Mean maximum flexion of affected knees was 114.08°. The results of knee gait analysis were comparable with normal population data. Our work suggests that personalized titanium plates can significantly improve the clinical outcomes in the surgical removal of bone tumor. This study represents the first-time effort in using personalized titanium plates for such surgery.
Collapse
|
30
|
Jeys L, Morris G, Evans S, Stevenson J, Parry M, Gregory J. Surgical Innovation in Sarcoma Surgery. Clin Oncol (R Coll Radiol) 2017; 29:489-499. [PMID: 28502707 DOI: 10.1016/j.clon.2017.04.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 03/30/2017] [Accepted: 04/05/2017] [Indexed: 12/24/2022]
Abstract
The field of orthopaedic oncology relies on innovative techniques to resect and reconstruct a bone or soft tissue tumour. This article reviews some of the most recent and important innovations in the field, including biological and implant reconstructions, together with computer-assisted surgery. It also looks at innovations in other fields of oncology to assess the impact and change that has been required by surgeons; topics including surgical margins, preoperative radiotherapy and future advances are discussed.
Collapse
Affiliation(s)
- L Jeys
- Royal Orthopaedic Hospital, Birmingham, UK; School of Health and Life Sciences, Aston University, Birmingham, UK.
| | - G Morris
- Royal Orthopaedic Hospital, Birmingham, UK
| | - S Evans
- Royal Orthopaedic Hospital, Birmingham, UK
| | | | - M Parry
- Royal Orthopaedic Hospital, Birmingham, UK
| | - J Gregory
- Royal Orthopaedic Hospital, Birmingham, UK
| |
Collapse
|
31
|
Cartiaux O, Jenny JY, Joskowicz L. Accuracy of Computer-Aided Techniques in Orthopaedic Surgery: How Can It Be Defined, Measured Experimentally, and Analyzed from a Clinical Perspective? J Bone Joint Surg Am 2017; 99:e39. [PMID: 28419041 DOI: 10.2106/jbjs.15.01347] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Surgical accuracy is multifactorial. Therefore, it is crucial to consider all influencing factors when investigating the accuracy of a surgical procedure, such as the surgeon's experience, the assistive technologies that may be used by the surgeon, and the patient factors associated with the specific anatomical site. For in vitro preclinical investigations, accuracy should be linked to the concepts of trueness (e.g., distance from the surgical target) and precision (e.g., variability in relation to the surgical target) to gather preclinical, quantitative, objective data on the accuracy of completed surgical procedures that have been performed with assistive technologies. The clinical relevance of improvements in accuracy that have been observed experimentally may be evaluated by analyzing the impact on the risk of failure and by taking into account the level of tolerance in relation to the surgical target (e.g., the extent of the safety zone). The International Organization for Standardization (ISO) methodology enables preclinical testing of new assistive technologies to quantify improvements in accuracy and assess the benefits in terms of reducing the risk of failure and achieving surgical targets with tighter tolerances before the testing of clinical outcomes.
Collapse
Affiliation(s)
- Olivier Cartiaux
- 1Computer Assisted and Robotic Surgery, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium 2Centre de Chirurgie Orthopédique et de la Main, Les Hôpitaux Universitaires de Strasbourg, Illkirch, France 3The Rachel and Selim Benin School of Computer Science and Engineering, The Hebrew University of Jerusalem, Jerusalem, Israel
| | | | | |
Collapse
|
32
|
Abstract
Treatment of bone sarcoma requires careful planning and involvement of an experienced multidisciplinary team. Significant advancements in systemic therapy, radiation, and surgery in recent years have contributed to improved functional and survival outcomes for patients with these difficult tumors, and emerging technologies hold promise for further advancement.
Collapse
Affiliation(s)
- Christina J Gutowski
- Department of Orthopedic Surgery, Sidney Kimmel Medical College at Thomas Jefferson University, 1025 Walnut Street, Room 516 College, Philadelphia, PA 19107, USA
| | - Atrayee Basu-Mallick
- Department of Medical Oncology, Sarcoma and Bone Tumor Center at Sidney Kimmel Cancer Center, Thomas Jefferson University Hospital, 1025 Walnut Street, Suite 700, Philadelphia, PA 19107
| | - John A Abraham
- Department of Orthopedic Surgery, Rothman Institute at Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107, USA; Department of Surgical Oncology, Fox Chase Cancer Center, 333 Cottman Ave, Philadelphia, PA 19111, USA.
| |
Collapse
|
33
|
Abstract
With advances in both medical imaging and computer programming, two-dimensional axial images can be processed into other reformatted views (sagittal and coronal) and three-dimensional (3D) virtual models that represent a patients’ own anatomy. This processed digital information can be analyzed in detail by orthopedic surgeons to perform patient-specific orthopedic procedures. The use of 3D printing is rising and has become more prevalent in medical applications over the last decade as surgeons and researchers are increasingly utilizing the technology’s flexibility in manufacturing objects. 3D printing is a type of manufacturing process in which materials such as plastic or metal are deposited in layers to create a 3D object from a digital model. This additive manufacturing method has the advantage of fabricating objects with complex freeform geometry, which is impossible using traditional subtractive manufacturing methods. Specifically in surgical applications, the 3D printing techniques can not only generate models that give a better understanding of the complex anatomy and pathology of the patients and aid in education and surgical training, but can also produce patient-specific surgical guides or even custom implants that are tailor-made to the surgical requirements. As the clinical workflow of the 3D printing technology continues to evolve, orthopedic surgeons should embrace the latest knowledge of the technology and incorporate it into their clinical practice for patient-specific orthopedic applications. This paper is written to help orthopedic surgeons stay up-to-date on the emerging 3D technology, starting from the acquisition of clinical imaging to 3D printing for patient-specific applications in orthopedics. It 1) presents the necessary steps to prepare the medical images that are required for 3D printing, 2) reviews the current applications of 3D printing in patient-specific orthopedic procedures, 3) discusses the potential advantages and limitations of 3D-printed custom orthopedic implants, and 4) suggests the directions for future development. The 3D printing technology has been reported to be beneficial in patient-specific orthopedics, such as in the creation of anatomic models for surgical planning, education and surgical training, patient-specific instruments, and 3D-printed custom implants. Besides being anatomically conformed to a patient’s surgical requirement, 3D-printed implants can be fabricated with scaffold lattices that may facilitate osteointegration and reduce implant stiffness. However, limitations including high cost of the implants, the lead time in manufacturing, and lack of intraoperative flexibility need to be addressed. New biomimetic materials have been investigated for use in 3D printing. To increase utilization of 3D printing technology in orthopedics, an all-in-one computer platform should be developed for easy planning and seamless communications among different care providers. Further studies are needed to investigate the real clinical efficacy of 3D printings in orthopedic applications.
Collapse
Affiliation(s)
- Kwok Chuen Wong
- Department of Orthopedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong,
| |
Collapse
|
34
|
3D-printed guiding templates for improved osteosarcoma resection. Sci Rep 2016; 6:23335. [PMID: 26997197 PMCID: PMC4800413 DOI: 10.1038/srep23335] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 03/04/2016] [Indexed: 12/16/2022] Open
Abstract
Osteosarcoma resection is challenging due to the variable location of tumors and their proximity with surrounding tissues. It also carries a high risk of postoperative complications. To overcome the challenge in precise osteosarcoma resection, computer-aided design (CAD) was used to design patient-specific guiding templates for osteosarcoma resection on the basis of the computer tomography (CT) scan and magnetic resonance imaging (MRI) of the osteosarcoma of human patients. Then 3D printing technique was used to fabricate the guiding templates. The guiding templates were used to guide the osteosarcoma surgery, leading to more precise resection of the tumorous bone and the implantation of the bone implants, less blood loss, shorter operation time and reduced radiation exposure during the operation. Follow-up studies show that the patients recovered well to reach a mean Musculoskeletal Tumor Society score of 27.125.
Collapse
|
35
|
Wong KC, Kumta SM, Geel NV, Demol J. One-step reconstruction with a 3D-printed, biomechanically evaluated custom implant after complex pelvic tumor resection. ACTA ACUST UNITED AC 2015; 20:14-23. [PMID: 26290317 DOI: 10.3109/10929088.2015.1076039] [Citation(s) in RCA: 146] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- K C Wong
- a Department of Orthopaedics and Traumatology , Prince of Wales Hospital , Shatin , Hong Kong and
| | - S M Kumta
- a Department of Orthopaedics and Traumatology , Prince of Wales Hospital , Shatin , Hong Kong and
| | - N V Geel
- b Mobelife NV , Leuven , Belgium
| | - J Demol
- b Mobelife NV , Leuven , Belgium
| |
Collapse
|
36
|
Patient-specific instrument can achieve same accuracy with less resection time than navigation assistance in periacetabular pelvic tumor surgery: a cadaveric study. Int J Comput Assist Radiol Surg 2015; 11:307-16. [PMID: 26148694 DOI: 10.1007/s11548-015-1250-x] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Accepted: 06/17/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. METHODS We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. RESULTS The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. CONCLUSIONS In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.
Collapse
|
37
|
Abstract
From an era where amputation was the only option to the current day function preserving resections and complex reconstructions has been a major advance in the treatment of musculoskeletal sarcomas. The objectives of extremity reconstruction after oncologic resection include providing skeletal stability where necessary, adequate wound coverage to allow early subsequent adjuvant therapy, optimising the aesthetic outcome and preservation of functional capability with early return to function. This article highlights the concepts of surgical margins in oncology, discusses the principles governing safe surgical resection in these tumors and summarises the current modalities and recent developments relevant to reconstruction after limb salvage. The rationale of choice of a particular resection modality and the unique challenges of reconstruction in skeletally immature individuals are also discussed. Striking the right balance between adequate resection, while yet retaining or reconstructing tissue for acceptable function and cosmesis is a difficult task. Complications are not uncommon and patients and their families need to be counseled regarding the potential setbacks that may occur in the course of their eventual road to recovery, Limb salvage entails a well orchestrated effort involving various specialties and better outcomes are likely to be achieved with centralization of expertise at regional centers.
Collapse
Affiliation(s)
- Ajay Puri
- Department of Orthopaedic Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India,Address for correspondence: Prof. Ajay Puri, Room No. 45, Tata Memorial Hospital, E. Borges Road, Parel, Mumbai - 400 012, Maharashtra, India. E-mail:
| |
Collapse
|
38
|
Abstract
The treatment of musculoskeletal sarcomas has made vast strides in the last few decades. From an era where amputation was the only option to the current day function preserving resections and complex reconstructions has been a major advance. The objectives of extremity reconstruction after oncologic resection include providing skeletal stability where necessary, adequate wound coverage to allow early subsequent adjuvant therapy, optimising the aesthetic outcome and preservation of functional capability with early return to function. This article highlights the concepts of surgical margins in oncology, discusses the principles governing safe surgical resection in these tumors and summarises the current modalities and recent developments relevant to reconstruction after limb salvage. The rationale of choice of a particular resection modality, the unique challenges of reconstruction in skeletally immature individuals and the impact of adjuvant modalities like chemotherapy and radiotherapy on surgical outcomes are also discussed.
Collapse
Affiliation(s)
- Ajay Puri
- Department of Orthopaedic Oncology Tata Memorial Hospital, Parel, Mumbai, Maharashtra, India
| |
Collapse
|
39
|
Computer-Assisted Planning and Patient-Specific Instruments for Bone Tumor Resection within the Pelvis: A Series of 11 Patients. Sarcoma 2014; 2014:842709. [PMID: 25100921 PMCID: PMC4101950 DOI: 10.1155/2014/842709] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 06/09/2014] [Accepted: 06/09/2014] [Indexed: 12/15/2022] Open
Abstract
Pelvic bone tumor resection is challenging due to complex geometry, limited visibility, and restricted workspace. Accurate resection including a safe margin is required to decrease the risk of local recurrence. This clinical study reports 11 cases of pelvic bone tumor resected by using patient-specific instruments. Magnetic resonance imaging was used to delineate the tumor and computerized tomography to localize it in 3D. Resection planning consisted in desired cutting planes around the tumor including a safe margin. The instruments were designed to fit into unique position on the bony structure and to indicate the desired resection planes. Intraoperatively, instruments were positioned freehand by the surgeon and bone cutting was performed with an oscillating saw. Histopathological analysis of resected specimens showed tumor-free bone resection margins for all cases. Available postoperative computed tomography was registered to preoperative computed tomography to measure location accuracy (minimal distance between an achieved and desired cut planes) and errors on safe margin (minimal distance between the achieved cut planes and the tumor boundary). The location accuracy averaged 2.5 mm. Errors in safe margin averaged −0.8 mm. Instruments described in this study may improve bone tumor surgery within the pelvis by providing good cutting accuracy and clinically acceptable margins.
Collapse
|
40
|
Abstract
The use of computer navigation was first described in the surgical resection of pelvic tumors in 2004. It was developed to improve surgical accuracy with the goal of achieving clear resection margins and better oncologic results. During the past few years, there has been tremendous advancement of computer-assisted tumor surgery (CATS) in the field of orthopedic oncology. Currently, CATS with image fusion offers preoperative three-dimensional surgical planning and allows surgeons to reproduce the intended bone resections in musculoskeletal tumors. The technique is reported to be useful in technically demanding resections, such as in pelvic and sacral tumors; joint-preserving intercalated and multiplanar tumor resection; and complex reconstruction with custom computer-aided design prostheses or allografts. This article provides an up-to-date review of the recent developments and key features in CATS, its current status in clinical practice, and future directions in its development.
Collapse
Affiliation(s)
- Kwok-Chuen Wong
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Shatin, Hong Kong
| | - Shekhar-Madhukar Kumta
- Department of Orthopaedics and Traumatology, Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong
| |
Collapse
|
41
|
Ding HW, Yu GW, Tu Q, Liu B, Shen JJ, Wang H, Wang YJ. Computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee: outcomes of 12 cases. BMC Musculoskelet Disord 2013; 14:331. [PMID: 24267157 PMCID: PMC4222761 DOI: 10.1186/1471-2474-14-331] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2013] [Accepted: 11/13/2013] [Indexed: 12/14/2022] Open
Abstract
Background To report the outcomes of computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee. Methods Computed tomography (CT) and magnetic resonance imaging (MRI) data were input into computer software to produce three-dimensional (3D) models of the tumor extent. Imaging data was then used to create a template for surgical resection, and development of an individualized combined allogeneic bone/endoprosthesis. Surgical simulations were performed prior to the actual surgery. Results This study included 9 males and 3 females with a mean age of 25.3 years (range, 13 to 40 years). There were 9 tumors in the distal femur and 3 in the proximal tibia. There were no surgical complications. In all cases pathologically confirmed clear surgical margins were obtained. Postoperative radiographs showed the range of tumor resection was in accordance with the preoperative design, and the morphological reconstruction of the bone defect was satisfactory with complete bilateral symmetry. The mean follow-up time was 26.5 months. Two patients died of their disease and the remaining are alive and well without evidence of recurrence. All patients are able to ambulate freely without restrictions. At the last follow-up, the average International Society of Limb Salvage score was 25.8 (range, 18 to 27), and was excellent in 8 cases and good in 4 cases. Conclusions Computer-aided design and modeling for the surgical management of bone tumors and subsequent limb reconstruction provides accurate tumor removal with the salvage of a maximal amount of unaffected bone and precise endoprosthesis reconstruction.
Collapse
Affiliation(s)
- Huan-wen Ding
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, Guangdong 510010, China.
| | | | | | | | | | | | | |
Collapse
|
42
|
Improved accuracy with 3D planning and patient-specific instruments during simulated pelvic bone tumor surgery. Ann Biomed Eng 2013; 42:205-13. [PMID: 23963884 DOI: 10.1007/s10439-013-0890-7] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Accepted: 08/07/2013] [Indexed: 10/26/2022]
Abstract
In orthopaedic surgery, resection of pelvic bone tumors can be inaccurate due to complex geometry, limited visibility and restricted working space of the pelvis. The present study investigated accuracy of patient-specific instrumentation (PSI) for bone-cutting during simulated tumor surgery within the pelvis. A synthetic pelvic bone model was imaged using a CT-scanner. The set of images was reconstructed in 3D and resection of a simulated periacetabular tumor was defined with four target planes (ischium, pubis, anterior ilium, and posterior ilium) with a 10-mm desired safe margin. Patient-specific instruments for bone-cutting were designed and manufactured using rapid-prototyping technology. Twenty-four surgeons (10 senior and 14 junior) were asked to perform tumor resection. After cutting, ISO1101 location and flatness parameters, achieved surgical margins and the time were measured. With PSI, the location accuracy of the cut planes with respect to the target planes averaged 1 and 1.2 mm in the anterior and posterior ilium, 2 mm in the pubis and 3.7 mm in the ischium (p < 0.0001). Results in terms of the location of the cut planes and the achieved surgical margins did not reveal any significant difference between senior and junior surgeons (p = 0.2214 and 0.8449, respectively). The maximum differences between the achieved margins and the 10-mm desired safe margin were found in the pubis (3.1 and 5.1 mm for senior and junior surgeons respectively). Of the 24 simulated resection, there was no intralesional tumor cutting. This study demonstrates that using PSI technology during simulated bone cuts of the pelvis can provide good cutting accuracy. Compared to a previous report on computer assistance for pelvic bone cutting, PSI technology clearly demonstrates an equivalent value-added for bone cutting accuracy than navigation technology. When in vivo validated, PSI technology may improve pelvic bone tumor surgery by providing clinically acceptable margins.
Collapse
|