1
|
Serafin K, Nocun AA, Zawisza K, Dudzik MM, Wiechec MT. Comparison of Left Ventricular Stroke Volume in 2nd- and 3rd-Trimester Fetuses Measured by the Product of VTI and Aortic Annular Area With That Assessed by Simpson's Single-Plane Rule Using the STE Technique. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:1319-1331. [PMID: 38567690 DOI: 10.1002/jum.16456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/02/2024] [Accepted: 03/16/2024] [Indexed: 04/04/2024]
Abstract
OBJECTIVES The aim of the study was to compare left ventricle stroke volume in healthy, eutrophic fetuses in the 2nd and 3rd trimesters evaluated using the velocity time integral and aortic annulus area with left ventricular stroke volume measured using Simpson's single-plane rule and to determine the discrepancy equation. METHODS The study included 354 fetuses. In each fetus, during the same examination, simultaneous assessment of stroke volume was performed by pulsed-wave Doppler using the product of the velocity time integral and aortic annulus area and by the fetalHQ® software using Simpson's single-plane rule. The Mann-Whitney U test was used to compare the "product-derived" stroke volume and stroke volume using fetalHQ® software values in the 2nd and 3rd trimesters separately. The agreement between the two methods were verified using Bland-Altman analysis. A linear regression model was used to obtain the discrepancy equation. RESULTS In the 2nd trimester, the mean percentage difference between both the techniques showed that the stroke volume values determined using pulsed-wave Doppler were, on average, 88% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 146% and the lower limit of agreement was equal to 29.6%. In the 3rd trimester, the results indicated that the stroke volume values determined using pulsed-wave Doppler were, on average, 76% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 129% and the lower limit of agreement was 23%. Based on the results of the linear regression models, discrepancy formulas of the stroke volume values were obtained. The equations to calculate the predicted mean and standard deviations were used to compute the reference intervals for the mean, 5th and 95th centiles. CONCLUSION The calculation of left ventricular stroke volume using pulsed Doppler has higher result in relation to stroke volume determined using Simpson's rule significantly. The aortic annulus area showed a higher correlation regarding stroke volume than the velocity time integral in both the 2nd and 3rd trimesters. Stroke volume increased with the increase in aortic annulus area, whereas the velocity time integral remained relatively constant. The retrospective analysis of the collected material enabled the determination of the discrepancy equation.
Collapse
Affiliation(s)
- Krzysztof Serafin
- Chair of Gynecology and Obstetrics, Faculty of Medicine, Jagiellonian University Medical College, Cracow, Poland
- Ultrasound Laboratory, ARS MEDICA Specialist Gynecology and Obstetrics Clinic, Tarnow, Poland
| | - Agnieszka A Nocun
- Ultrasound Laboratory, MWU DOBRE USG Center of Ultrasound Diagnostics, Cracow, Poland
| | - Katarzyna Zawisza
- Chair of Epidemiology and Preventive Medicine, Jagiellonian University Medical College, Cracow, Poland
| | - Magdalena M Dudzik
- Ultrasound Laboratory, MWU DOBRE USG Center of Ultrasound Diagnostics, Cracow, Poland
| | - Marcin T Wiechec
- Chair of Gynecology and Obstetrics, Faculty of Medicine, Jagiellonian University Medical College, Cracow, Poland
- Ultrasound Laboratory, MWU DOBRE USG Center of Ultrasound Diagnostics, Cracow, Poland
| |
Collapse
|
2
|
Bravo-Valenzuela NJ, Peixoto AB, Mattar R, Júnior EA. Fetal Interventricular Septum Volume Evaluated by Three-Dimensional Ultrasound Using Spatiotemporal Image Correlation and Virtual Organ Computer-Aided Analysis in Fetuses From Pre-Gestational Diabetes Mellitus Pregnant Women. J Cardiovasc Imaging 2022; 30:125-134. [PMID: 35505502 PMCID: PMC9058629 DOI: 10.4250/jcvi.2021.0170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 02/12/2022] [Accepted: 02/13/2022] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND To assess the interventricular septum (IVS) volume of fetuses from pre-gestational diabetes mellitus (DM) pregnant women by 3-dimensional ultrasound using spatiotemporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL) methods. METHODS This was a prospective cross-sectional study of 45 fetuses from pre-gestational DM and 45 fetuses from healthy pregnant women (controls). Only singleton pregnancies between 20 and 34 + 6 weeks of gestation were included. The fetal IVS volumes were obtained off-line using STIC and VOCAL methods. To analyze differences among variables, the Student’s t-test and Mann-Whitney U test were used. The correlation among continuous variables was determine using Spearman’s correlation test (r). RESULTS The median of fetal IVS volume was significantly higher in pre-gestational DM than in healthy pregnant women (0.3 cm3 vs. 0.2 cm3, p = 0.032). A strong positive correlation was observed between fetal IVS volume and gestational age at the time of ultrasound examination (r = 0.75, R2 = 0.48, p < 0.0001) and between fetal IVS volume and estimated fetal weight (r = 0.63, R2 = 0.37, p < 0.0001). No significant correlation was noted between fetal IVS volume and glycated hemoglobin levels (r = −0.16, R2 = 0.01, p = 0.540) in the pre-gestational DM pregnant women. CONCLUSIONS Significant differences were observed in fetal IVS volumes between pre-gestational and healthy mothers, with higher values in the fetuses of pre-gestational DM pregnant women.
Collapse
Affiliation(s)
- Nathalie Jeanne Bravo-Valenzuela
- Department of Pediatrics, Pediatric Cardiology, School of Medicine, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - Alberto Borges Peixoto
- Department of Obstetrics and Gynecology, Federal University of Triângulo Mineiro (UFTM), Uberaba, Brazil
- Gynecology and Obstetrics Service, Mario Palmério University Hospital, University of Uberaba (UNIUBE), Uberaba, Brazil
| | - Rosiane Mattar
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| |
Collapse
|
3
|
Melo Júnior JF, Bravo-Valenzuela NJ, Nardozza LMM, Peixoto AB, Mattar R, Martins WP, Pares DBDS, Araujo Júnior E. References Values of Fetal Heart Myocardial Volume by Three-Dimensional Ultrasound using Spatiotemporal Image Correlation and Virtual Organ Computer-Aided Analysis Methods and Their Applicability in Pregestational Diabetic Women. Am J Perinatol 2021; 38:721-727. [PMID: 31858500 DOI: 10.1055/s-0039-3400983] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVE To determine reference values for myocardial volume of the fetal heart using three-dimensional ultrasound with spatiotemporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL) and to assess their applicability in women with pregestational diabetes. STUDY DESIGN This retrospective cross-sectional study included 177 normal pregnant women with fetuses between 200/7 and 336/7 weeks of age. Fetal cardiac volumes were collected using the STIC method, and myocardial volume was obtained by subtraction of the intracavitary volumes using the VOCAL 30-degree method. Intra- and interobserver reproducibility values were determined using the concordance correlation coefficient (CCC). Sixteen women with pregestational diabetes mellitus were evaluated for validation. RESULTS There was a strong correlation between fetal myocardial volume and gestational age (R 2 = 0.82). Intra- and interobserver reproducibility values were excellent and moderate, respectively, with CCCs of 0.99 and 0.83, respectively. There was no significant difference in mean fetal myocardial volume between normal pregnant women and those with pregestational diabetes (p = 0.64). CONCLUSION Reference values for myocardial volume of the fetal heart were determined in normal pregnant women and were not statistically different from those in women with pregestational diabetes mellitus.
Collapse
Affiliation(s)
- José Francisco Melo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | | | | | - Alberto Borges Peixoto
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil.,Gynecology and Obstetrics Service, Mario Palmério University Hospital, University of Uberaba (UNIUBE), Uberaba, Brazil
| | - Rosiane Mattar
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | | | - David Baptista da Silva Pares
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| |
Collapse
|
4
|
Fetal Cardiac Function and Ventricular Volumes Determined by Three-Dimensional Ultrasound Using STIC and VOCAL Methods in Fetuses from Pre-gestational Diabetic Women. Pediatr Cardiol 2020; 41:1125-1134. [PMID: 32367304 DOI: 10.1007/s00246-020-02362-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 04/23/2020] [Indexed: 10/24/2022]
Abstract
To assess the fetal cardiac function and ventricular volumes by three-dimensional (3D) ultrasound using spatio-temporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL) methods in fetuses from pre-gestational diabetic women. This was a prospective and cross-sectional study that evaluated 53 fetuses from pre-gestational diabetic women and 53 fetuses from healthy mothers between 20 and 34 weeks of gestation. Only fetuses with no structural or genetic abnormalities and singleton pregnant women were included in this study. The fetal cardiac volumes were assessed by STIC and VOCAL methods. The ejection fraction, stroke volume, and cardiac output were calculated from these measurements to evaluate fetal cardiac function. The Mann-Whitney U test was performed to compare the two groups. For calculation of intra- and interobserver reproducibility's, we used concordance correlation coefficients. The mean differences in the right atrial volumes between the diabetic and normal groups ranged from 0.05 mL to 0.1 mL (p = 0.917 and 0.355, respectively). The median of left atrium (LA) volume measurement in pre-gestational diabetic group was significantly lower than healthy mothers (LA: 0.62 vs. 0.68 mL; p < 0.001). The fetal right and left ventricular volumes were similar in both groups. No significant differences in ejection fraction, stroke volume and cardiac output were observed (p value range 0.086-0.815). The majority of fetal atrial/ventricular volumes showed good intra- and interobserver reliabilities. Conversely, the majority cardiac function parameters showed poor intra- and interobserver agreements. STIC and VOCAL methods gave reproducible quantitative results for fetal atrial and ventricular volumes. Significant differences in fetal left atrial volumes were observed between the two groups, which be related to LA atrial dysfunction and /or left ventricle (LV) compliance, reflecting earlier stages of cardiac dysfunction.
Collapse
|
5
|
Pepes S, Parthenakis F, Makrigiannakis A, Germanakis I. Electronic versus conventional spatiotemporal image correlation (STIC) fetal echocardiography: a direct comparison. J Matern Fetal Neonatal Med 2020; 35:1310-1317. [PMID: 32295436 DOI: 10.1080/14767058.2020.1752656] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Objectives: Recent advances in Spatial Temporal Image Correlation (STIC) 4 D fetal echocardiography include the application of eSTIC based on electronic probe image acquisition. We aimed to directly compare the performance of conventional STIC versus eSTIC technique (B-Mode and color Doppler imaging) during off-line reconstruction of STIC/eSTIC fetal heart volume pairs.Methods: Pairs of B-Mode and Color Doppler STIC volumes were acquired sequentially by firstly conventional (STIC) followed by electronic (eSTIC) probes during 33 consecutive obstetric scans at median 23 (range 13-31) gestational weeks. The resulting 66 fetal heart volume pairs were assessed blindly off-line by a fetal cardiologist who documented feasibility of reconstruction, presence of motion artifacts, subjective image quality on a 4-level scale: 1-best to 4-non-diagnostic and morphological diagnosis, to enable a paired comparison of STIC and eSTIC in the same fetus under similar scanning conditions.Results: eSTIC volumes had higher temporal resolution (37 vs. 24 frames per second, p < .001), less motion during acquisition (12 vs. 20 cases, O.R. 7.0, p = .002) and better average image quality (1.9 vs. 2.2, p = .006) compared to STIC volumes. More diagnostic reconstructions were achieved by eSTIC (n = 55, 86%) than STIC (n = 52, 78.8%), p = .001), in a comparable analysis time (mean 4.96 vs. 4.94 min). During a comparison of image quality of the original acquisition (A) and reconstructed planes (B and C planes) e STIC was superior in 22 (33%), 39 (59%) and 21 (38%) volumes, respectively, with the remaining cases being of similar quality (<10% in each plane in favor of STIC). Imaging mode and gestational age had a similar impact on both eSTIC and STIC performance: diagnostically acceptable studies in 49 (75.8%) vs. 48 (72.2%) by B-Mode, 60 (90.9%) vs. 56 (84.8%) by Color Doppler Mode, 8 (62.5%) vs. 10 (50%) in early scans, 38 (95%) vs. 38 (95%) in mid-gestation scans, and 7 (70%) vs. 6 (60%) in third trimester scans. Eight obstetric scans identified a fetus with a cardiac variant or structural abnormality. Diagnostic concordance of the two STIC approaches was comparable (40/48 concordant interpretations, kappa 0.657) all confirmed by fetal and/or postnatal echocardiography.Conclusions: eSTIC was associated with more effective 4 D fetal heart reconstruction due to reduced motion artifacts and superior image quality in all planes, when compared to STIC. Early gestation reconstructions were not generally successful using either technology. Further study is needed to define the cost-effectiveness and diagnostic impact of eSTIC over conventional STIC and their role over, or in addition to, screening 2 D fetal echocardiography by appropriately trained sonographers.
Collapse
Affiliation(s)
- Spiridon Pepes
- School of Medicine, University of Crete, Heraklion, Greece
| | | | - Antonis Makrigiannakis
- Department of Obstetrics and Gynecology, School of Medicine, University of Crete, Heraklion, Greece
| | - Ioannis Germanakis
- Department of Pediatrics, School of Medicine, University of Crete, Heraklion, Greece
| |
Collapse
|
6
|
Bravo-Valenzuela NJ, Peixoto AB, Carrilho MC, Siqueira Pontes AL, Chagas CC, Simioni C, Araujo Júnior E. Fetal cardiac function by three-dimensional ultrasound using 4D-STIC and VOCAL - an update. J Ultrason 2019; 19:287-294. [PMID: 32021711 PMCID: PMC6988455 DOI: 10.15557/jou.2019.0043] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 10/16/2019] [Indexed: 01/13/2023] Open
Abstract
Three- and four-dimensional (3D/4D) ultrasonography with spatio-temporal image correlation (4D-STIC) allows obtaining fetal cardiac volumes and their static and real-time analysis in multiplanar and rendering modes. Cardiac biometrics and Doppler-echocardiographic parameters for evaluation of fetal heart function, including cardiac output and stroke volume, can be analyzed using M-mode, two-dimensional (2D), and 3D/4D cardiac ultrasound. In recent years, functional echocardiography has been used to study fetuses without a structurally cardiac defect but who are at risk of heart failure due to the presence of extra-cardiac conditions, such as, fetal growth restriction, tumors/masses, twin-to-twin transfusion syndrome, fetal anemia (Rh alloimmunization), congenital infections, or maternal diabetes mellitus. The assessment of cardiac function provides important information on hemodynamic status and can help optimize the best time for delivery and reduce perinatal morbidity and mortality. Since 2003, with the advent of the 4D-STIC software, it is possible to evaluate the fetal heart in multiplanar, and rendering modes. This technology associated with virtual organ computer-aided analysis (VOCAL) enables determining the ventricular volume (end-diastole, end-systole), the stroke-volume, the ejection fraction, and the cardiac output of each ventricle. Since 2004, several studies demonstrated that the 4D-STIC and VOCAL had good reproducibility to measure cardiac volumes This study reviews published studies that evaluated the fetal cardiac function by 3D ultrasound using 4D-STIC and VOCAL software.
Collapse
Affiliation(s)
| | - Alberto Borges Peixoto
- Department of Obstetrics and Gynecology, Federal University of Triângulo Mineiro (UFTM), Uberaba-MG, Brazil
| | - Milene Carvalho Carrilho
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Ana Letícia Siqueira Pontes
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Caroline Cevante Chagas
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Christiane Simioni
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| |
Collapse
|
7
|
Rocha LA, Rolo LC, Araujo Júnior E. How to perform a functional assessment of the fetal heart: a pictorial review. Ultrasonography 2019; 38:365-373. [PMID: 31288508 PMCID: PMC6773963 DOI: 10.14366/usg.18065] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 02/07/2019] [Indexed: 11/24/2022] Open
Abstract
The purpose of this pictorial review was to describe various echocardiographic techniques that can be used for the functional assessment of the fetal heart. The systolic and diastolic assessments of the fetal heart are presented separately, with an emphasis on 2-dimensional Doppler methods and an overview of new technologies. The aim of this summary was to review the tools that can be used by the echocardiographer, and on that basis, to systematize the process of performing a functional assessment.
Collapse
Affiliation(s)
- Luciane Alves Rocha
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPMUNIFESP), São Paulo, Brazil
| | - Liliam Cristine Rolo
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPMUNIFESP), São Paulo, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPMUNIFESP), São Paulo, Brazil
| |
Collapse
|
8
|
Abstract
With the introduction of the electronic 4-dimensional and spatial-temporal image Correlation (e-STIC), it is now possible to obtain large volume datasets of the fetal heart that are virtually free of artifact. This allows the examiner to use a number of imaging modalities when recording the volumes that include two-dimensional real time, power and color Doppler, and B-flow images. Once the volumes are obtained, manipulation of the volume dataset allows the examiner to recreate views of the fetal heart that enable examination of cardiac anatomy. The value of this technology is that a volume of the fetal heart can be obtained, irrespective of the position of the fetus in utero, and manipulated to render images for interpretation and diagnosis. This article presents a summary of the various imaging techniques and provides clinical examples of its application used for prenatal diagnosis of congenital heart defects and abnormal cardiac function.
Collapse
Affiliation(s)
- Greggory R DeVore
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,Fetal Diagnostic Centers, Pasadena, Tarzana, and Lancaster, CA, USA
| | - Gary Satou
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - Mark Sklansky
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|