1
|
Yoon YS, Whitaker R, White N. Frequency importance functions in simulated bimodal cochlear-implant users with spectral holes. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:3589-3599. [PMID: 38829154 PMCID: PMC11151433 DOI: 10.1121/10.0026220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 04/29/2024] [Accepted: 05/12/2024] [Indexed: 06/05/2024]
Abstract
Frequency importance functions (FIFs) for simulated bimodal hearing were derived using sentence perception scores measured in quiet and noise. Acoustic hearing was simulated using low-pass filtering. Electric hearing was simulated using a six-channel vocoder with three input frequency ranges, resulting in overlap, meet, and gap maps, relative to the acoustic cutoff frequency. Spectral holes present in the speech spectra were created within electric stimulation by setting amplitude(s) of channels to zero. FIFs were significantly different between frequency maps. In quiet, the three FIFs were similar with gradually increasing weights with channels 5 and 6 compared to the first three channels. However, the most and least weighted channels slightly varied depending on the maps. In noise, the patterns of the three FIFs were similar to those in quiet, with steeper increasing weights with channels 5 and 6 compared to the first four channels. Thus, channels 5 and 6 contributed to speech perception the most, while channels 1 and 2 contributed the least, regardless of frequency maps. Results suggest that the contribution of cochlear implant frequency bands for bimodal speech perception depends on the degree of frequency overlap between acoustic and electric stimulation and if noise is absent or present.
Collapse
Affiliation(s)
- Yang-Soo Yoon
- Department of Communication Sciences and Disorders, Baylor University, Waco, Texas 76798, USA
| | - Reagan Whitaker
- Department of Hearing and Speech Sciences, Vanderbilt University, Nashville, Tennessee 37232, USA
| | - Naomi White
- Department of Communication Sciences and Disorders, Baylor University, Waco, Texas 76798, USA
| |
Collapse
|
2
|
Eichler T, Lakomek A, Waschkies L, Meyer M, Sadok N, Lang S, Arweiler-Harbeck D. Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility. Eur Arch Otorhinolaryngol 2024; 281:2913-2920. [PMID: 38170210 PMCID: PMC11065901 DOI: 10.1007/s00405-023-08400-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE The study explores the potential of real-time electrocochleographic potentials (ECochG) visualization during electrode insertion using digital microscopes such as RoboticScope (BHS®). Collaborative software development of the MAESTRO Software (MED-EL®) offers continuous ECochG monitoring during implantation and postoperative hearing evaluation, addressing previous time constraints. The study aims to assess software applicability and the impact of real-time visualization on long-term residual hearing preservation. METHODS Eight patients with residual hearing underwent cochlear implantation with Flex26 or Flex28 electrode according to the Otoplan evaluation. ECochG responses were measured and visualized during electrode insertion, with insertion times recorded. Two randomized display methods (graph and arrows) tracked ECochG potentials. Postoperative behavioral thresholds determined hearing preservation. Successful real-time intraoperative ECochG visualization was achieved in all cases, enabling surgeon adaptation. Mean electrode insertion time was 114 s, with postoperative thresholds comparable to preoperative values. Visualization did not affect surgeon workload. ECochG amplitudes differed between patients with and without residual hearing. CONCLUSION The study demonstrates effective implementation of advanced ECochG software combined with real-time visualization, enabling residual hearing preservation during CI. Visualization had no apparent effect on surgeon performance or workload. Future investigation involving a larger population will assess the long-term impact of ECochG on hearing threshold and structure preservation.
Collapse
Affiliation(s)
- Theda Eichler
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany.
| | - Antonia Lakomek
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| | - Laura Waschkies
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| | - Moritz Meyer
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| | - Nadia Sadok
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| | - Stephan Lang
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| | - Diana Arweiler-Harbeck
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Essen, Essen, Germany
| |
Collapse
|
3
|
Nyirjesy SC, Lewis JH, Hallak D, Conroy S, Moberly AC, Tamati TN. Evaluating Listening Effort in Unilateral, Bimodal, and Bilateral Cochlear Implant Users. Otolaryngol Head Neck Surg 2024; 170:1147-1157. [PMID: 38104319 DOI: 10.1002/ohn.609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/24/2023] [Accepted: 11/24/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVE Evaluate listening effort (LE) in unilateral, bilateral, and bimodal cochlear implant (CI) users. Establish an easy-to-implement task of LE that could be useful for clinical decision making. STUDY DESIGN Prospective cohort study. SETTING Tertiary neurotology center. METHODS The Sentence Final Word Identification and Recall Task, an established measure of LE, was modified to include challenging listening conditions (multitalker babble, gender, and emotional variation; test), in addition to single-talker sentences (control). Participants listened to lists of sentences in each condition and recalled the last word of each sentence. LE was quantified by percentage of words correctly recalled and was compared across conditions, across CI groups, and within subjects (best aided vs monaural). RESULTS A total of 24 adults between the ages of 37 and 82 years enrolled, including 4 unilateral CI users (CI), 10 bilateral CI users (CICI), and 10 bimodal CI users (CIHA). Task condition impacted LE (P < .001), but hearing configuration and listener group did not (P = .90). Working memory capacity and contralateral hearing contributed to individual performance. CONCLUSION This study adds to the growing body of literature on LE in challenging listening conditions for CI users and demonstrates feasibility of a simple behavioral task that could be implemented clinically to assess LE. This study also highlights the potential benefits of bimodal hearing and individual hearing and cognitive factors in understanding individual differences in performance, which will be evaluated through further research.
Collapse
Affiliation(s)
- Sarah C Nyirjesy
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
| | - Jessica H Lewis
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
- Department of Speech and Hearing Science, The Ohio State University, Columbus, Ohio, USA
| | - Diana Hallak
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
| | - Sara Conroy
- Department of Biomedical Informatics, Center for Biostatistics, The Ohio State University, Columbus, Ohio, USA
| | - Aaron C Moberly
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Terrin N Tamati
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
4
|
Höing B, Eichler T, Juelly V, Meyer M, Jung L, Waschkies L, Lang S, Arweiler-Harbeck D. Digital live imaging of intraoperative electrocochleography during cochlear implantation: the first 50 patients. Eur Arch Otorhinolaryngol 2024; 281:1175-1183. [PMID: 37646794 PMCID: PMC10858150 DOI: 10.1007/s00405-023-08197-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 08/17/2023] [Indexed: 09/01/2023]
Abstract
INTRODUCTION Real-time visualization of intraoperative electrocochleography (ECochG) potentials via a digital microscope during cochlear implantation can provide direct feedback during electrode insertion. The aim of this prospective, randomized study of 50 patients was to obtain long-term data with a focus on residual hearing preservation and speech understanding. MATERIAL AND METHODS Cochlear implantations were performed in 50 patients (26 female, 24 male) with residual hearing using a digital microscope. Patients were randomized into two groups. Intraoperative ECochG potentials were either displayed directly in the surgeon's field of view (picture-in-picture display, PiP) or not directly in the field of view (without picture-in-picture display, without PiP). Residual hearing preservation and speech comprehension were recorded within a 1-year follow-up period, compared between groups (PiP versus without PiP) and to a control group of 26 patients implanted without ECochG. RESULTS Mean insertion time was significantly longer in the picture-in-picture group (p = 0.025). Residual hearing preservation after 6 weeks at 250 Hz was significantly better in the picture-in-picture group (p = 0.017). After one year, 76% of patients showed residual hearing in the picture-in-picture group (62% without picture-in-picture technique, p = n.s.). Use of the picture-in-picture technique resulted in better long-term pure tone residual hearing preservation at 250, 500, and 1000 Hz. Speech intelligibility improved by 46% in the picture-in-picture group (38% without picture-in-picture). DISCUSSION This study is the first to describe long-term results in a large cohort of cochlear implant patients in whom digital visualization of intraoperative ECochG was used. Our results show that visualization of intraoperative ECochG has a positive effect on residual hearing preservation.
Collapse
Affiliation(s)
- Benedikt Höing
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.
| | - Theda Eichler
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Viktoria Juelly
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Moritz Meyer
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Lea Jung
- Cochlear Implant Rehabilitation Centre Ruhr (CIC), Essen, Germany
| | - Laura Waschkies
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Stephan Lang
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Diana Arweiler-Harbeck
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
| |
Collapse
|
5
|
Yoon YS, Straw S. Interactions Between Slopes of Residual Hearing and Frequency Maps in Simulated Bimodal and Electric-Acoustic Stimulation Hearing. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2024; 67:282-295. [PMID: 38092067 PMCID: PMC11000803 DOI: 10.1044/2023_jslhr-22-00629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 03/16/2023] [Accepted: 10/18/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE The aim of this study was to determine the effects of residual hearing slopes and cochlear implant frequency map settings on bimodal and electric-acoustic stimulation (EAS) benefits in speech perception. METHOD Adults with normal hearing were recruited for simulated bimodal and EAS hearing. Sentence perception was measured unilaterally and bilaterally. For the acoustic stimulation, three slopes of high-frequency hearing loss were created using low-pass filters with a cutoff frequency of 500 Hz: steep (96 dB/octave), medium (48 dB/octave), and shallow (24 dB/octave). For the electric stimulation, an eight-channel sinewave vocoder was used with an output frequency range (1000-7938 Hz) with three input frequency ranges to create frequency maps, overlap (188-7938 Hz), meet (500-7938 Hz), and gap (750-7938 Hz), relative to the cutoff frequency in the acoustic stimulation. RESULTS The largest bimodal/EAS benefit occurred with the shallow slope, and the smallest occurred with the steep slope. The effects of the slopes on bimodal/EAS benefit were greatest with the meet or gap map and the least with the overlap map. EAS benefit was greater than bimodal benefit at higher signal-to-noise ratios regardless of frequency map. CONCLUSIONS The results indicate that correlation between bimodal/EAS benefit and residual hearing could potentially improve if slopes were considered. The optimal frequency map differed with different slopes, suggesting that the slopes of residual hearing should be carefully considered in fitting bimodal and EAS hearing. EAS hearing provided greater benefit over bimodal hearing, suggesting that spectrotemporal integration was better within one ear (i.e., EAS) than across ears (i.e., bimodal).
Collapse
Affiliation(s)
- Yang-Soo Yoon
- Department of Communication Sciences and Disorders, Baylor University, Waco, TX
| | - Shea Straw
- Department of Communication Sciences and Disorders, Baylor University, Waco, TX
| |
Collapse
|
6
|
Prenzler NK, Salcher R, Lenarz T, Gaertner L, Lesinski-Schiedat A, Warnecke A. Deep intracochlear injection of triamcinolone-acetonide with an inner ear catheter in patients with residual hearing. Front Neurosci 2023; 17:1202429. [PMID: 37564369 PMCID: PMC10410142 DOI: 10.3389/fnins.2023.1202429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 07/10/2023] [Indexed: 08/12/2023] Open
Abstract
Introduction In a previous study, an inner ear catheter was used to deliver low- and high-dose steroids into the cochlea prior to cochlear implant electrode insertion. With this approach, more apical regions of the cochlea could be reached and a reduction of electrode impedances in the short term was achieved in cochlear implant recipients. Whether intracochlear application of drugs via the catheter is a safe method also for patients with residual hearing has not been investigated hitherto. The aim of the present study was therefore to investigate the effect of intracochlear triamcinolone application in cochlear implant recipients with residual hearing. Patients and methods Patients with residual hearing were administered triamcinolone-acetonide (4 mg/ml; n = 10) via an inner ear catheter just prior to insertion of a MED-EL FLEX28 electrode. Impedances were measured at defined time points (intra-operatively, post-operatively and at first fitting) and retrospectively compared with a control group (no steroid application) and low- and high-dose group. Hearing thresholds were measured preoperatively, 3 days after surgery and at first fitting by pure tone audiometry. Pre- to postoperative hearing loss was determined at first fitting and compared to results from a previous study. Results The median hearing loss after implantation (125-1,500 Hz) was 20.6 dB. Four patients (40%) showed a median hearing loss of less than 15 dB, three patients (30%) between 15 and 30 dB and three patients (30%) more than 30 dB. The median hearing loss was similar to the results obtained from our previous study showing a median hearing loss of 24 dB when using FLEX28 electrode arrays. Conclusion No difference in residual hearing loss was found when comparing application of triamcinolone-acetonide using an inner ear catheter prior to the insertion of a FLEX28 electrode array to the use of the FLEX28 electrode array without the catheter. Thus, we conclude that application of drugs to the cochlea with an inner ear catheter could be a feasible approach in patients with residual hearing.
Collapse
Affiliation(s)
- Nils K. Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
| | - Rolf Salcher
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
- Cluster of Excellence “Hearing 4 All” (DFG Exc. 2177), Hannover Medical School, Hanover, Germany
| | - Lutz Gaertner
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
| | - Anke Lesinski-Schiedat
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
| | - Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
- Cluster of Excellence “Hearing 4 All” (DFG Exc. 2177), Hannover Medical School, Hanover, Germany
| |
Collapse
|
7
|
Colby S, Seedorff M, McMurray B. Audiological and Demographic Factors that Impact the Precision of Speech Categorization in Cochlear Implant Users. Ear Hear 2023; 44:572-587. [PMID: 36542839 PMCID: PMC10101869 DOI: 10.1097/aud.0000000000001307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The ability to adapt to subtle variations in acoustic input is a necessary skill for successful speech perception. Cochlear implant (CI) users tend to show speech perception benefits from the maintenance of their residual acoustic hearing. However, previous studies often compare CI users in different listening conditions within-subjects (i.e., in their typical Acoustic + Electric configuration compared with Acoustic-only or Electric-only configurations) and comparisons among different groups of CI users do not always reflect an Acoustic + Electric benefit. Existing work suggests that CI users with residual acoustic hearing perform similarly to Electric-only listeners on phonetic voicing contrasts and unexpectedly poorer with fricative contrasts which have little energy in the range of the Acoustic + Electric listeners' acoustic hearing. To further investigate how residual acoustic hearing impacts sensitivity to phonetic ambiguity, we examined whether device configuration, age, and device experience influenced phonetic categorization in a large individual differences study. DESIGN CI users with various device configurations (Electric-only N = 41; Acoustic + Electric N = 95) categorized tokens from five /b-p/ and five /s-ʃ/ minimal pair continua (e.g., bet-pet; sock-shock). We investigated age, device experience, and when applicable, residual acoustic hearing (pure tone hearing thresholds) as predictors of categorization. We also examined the relationship between phonetic categorization and clinical outcomes (CNC, AzBio) in a subset of our sample. RESULTS Acoustic + Electric CI users were better able to categorize along the voicing contrast (steeper categorization slope) compared with Electric-only users, but there was no group-level difference for fricatives. There were differences within the subgroups for fricatives: bilateral users showed better categorization than unilateral users and bimodal users had better categorization than hybrid users. Age was a significant factor for voicing, while device experience was significant for fricatives. Critically, within the Acoustic + Electric group, hybrid CI users had shallower slopes than bimodal CI users. CONCLUSIONS Our findings suggest residual acoustic hearing is beneficial for categorizing stop voicing, but not frication. Age impacts the categorization of voicing, while device experience matters for fricatives. For CI users with ipsilateral residual acoustic hearing, those with better hearing thresholds may be over-relying on their acoustic hearing rather than extracting as much information as possible from their CI, and thus have shallower fricative categorization.
Collapse
Affiliation(s)
- Sarah Colby
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, Iowa, USA
- Department of Otolaryngology, University of Iowa, Iowa City, Iowa, USA
| | - Michael Seedorff
- Department of Biostatistics, University of Iowa, Iowa City, Iowa, USA
- Alphabet, Inc., Mountain View, California, USA
| | - Bob McMurray
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, Iowa, USA
- Department of Otolaryngology, University of Iowa, Iowa City, Iowa, USA
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, Iowa, USA
- Department of Linguistics, University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
8
|
Thomas M, Galvin JJ, Fu QJ. Importance of ipsilateral residual hearing for spatial hearing by bimodal cochlear implant users. Sci Rep 2023; 13:4960. [PMID: 36973380 PMCID: PMC10042848 DOI: 10.1038/s41598-023-32135-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 03/22/2023] [Indexed: 03/29/2023] Open
Abstract
AbstractBimodal cochlear implant (CI) listeners have difficulty utilizing spatial cues to segregate competing speech, possibly due to tonotopic mismatch between the acoustic input frequency and electrode place of stimulation. The present study investigated the effects of tonotopic mismatch in the context of residual acoustic hearing in the non-CI ear or residual hearing in both ears. Speech recognition thresholds (SRTs) were measured with two co-located or spatially separated speech maskers in normal-hearing adults listening to acoustic simulations of CIs; low frequency acoustic information was available in the non-CI ear (bimodal listening) or in both ears. Bimodal SRTs were significantly better with tonotopically matched than mismatched electric hearing for both co-located and spatially separated speech maskers. When there was no tonotopic mismatch, residual acoustic hearing in both ears provided a significant benefit when maskers were spatially separated, but not when co-located. The simulation data suggest that hearing preservation in the implanted ear for bimodal CI listeners may significantly benefit utilization of spatial cues to segregate competing speech, especially when the residual acoustic hearing is comparable across two ears. Also, the benefits of bilateral residual acoustic hearing may be best ascertained for spatially separated maskers.
Collapse
|
9
|
An overview of factors affecting bimodal and electric-acoustic stimulation (EAS) speech understanding outcomes. Hear Res 2023; 431:108736. [PMID: 36931019 DOI: 10.1016/j.heares.2023.108736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 02/13/2023] [Accepted: 03/04/2023] [Indexed: 03/08/2023]
Abstract
Improvements in device technology, surgical technique, and patient outcomes have resulted in a broadening of cochlear implantation criteria to consider those with increasing levels of useful low-to-mid frequency residual acoustic hearing. Residual acoustic hearing allows for the addition of a hearing aid (HA) to complement the cochlear implant (CI) and has demonstrated enhanced listening outcomes. However, wide inter-subject outcome variability exists and thus identification of contributing factors would be of clinical interest and may aid with pre-operative patient counselling. The optimal fitting procedure and frequency assignments for the two hearing devices used in combination to enhance listening outcomes also remains unclear. The understanding of how acoustic and electric speech information is fundamentally combined and utilised by the listener may allow for the optimisation of device fittings and frequency allocations to provide best bimodal and electric-acoustic stimulation (EAS) patient outcomes. This article will provide an overview of contributing factors to bimodal and EAS listening outcomes, explore areas of contention, and discuss common study limitations.
Collapse
|
10
|
Sharma N, Kumari D, Panigrahi I, Khetarpal P. A systematic review of the monogenic causes of Non-Syndromic Hearing Loss (NSHL) and discussion of Current Diagnosis and Treatment options. Clin Genet 2023; 103:16-34. [PMID: 36089522 DOI: 10.1111/cge.14228] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 09/02/2022] [Accepted: 09/06/2022] [Indexed: 12/13/2022]
Abstract
Hearing impairment is one of the most widespread inheritable sensory disorder affecting at least 1 in every 1000 born. About two-third of hereditary hearing loss (HHL) disorders are non-syndromic. To provide comprehensive update of monogenic causes of non-syndromic hearing loss (NSHL), literature search has been carried out with appropriate keywords in the following databases-PubMed, Google Scholar, Cochrane library, and Science Direct. Out of 2214 papers, 271 papers were shortlisted after applying inclusion and exclusion criterion. Data extracted from selected papers include information about gene name, identified pathogenic variants, ethnicity of the patient, age of onset, gender, title, authors' name, and year of publication. Overall, pathogenic variants in 98 different genes have been associated with NSHL. These genes have important role to play during early embryonic development in ear structure formation and hearing development. Here, we also review briefly the recent information about diagnosis and treatment approaches. Understanding pathogenic genetic variants are helpful in the management of affected and may offer targeted therapies in future.
Collapse
Affiliation(s)
- Nandita Sharma
- Department of Human Genetics and Molecular Medicine, School of Health Sciences, Central University of Punjab, Bathinda, India
| | - Divya Kumari
- Department of Pediatrics Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Inusha Panigrahi
- Department of Pediatrics Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Preeti Khetarpal
- Department of Human Genetics and Molecular Medicine, School of Health Sciences, Central University of Punjab, Bathinda, India
| |
Collapse
|
11
|
Jürgens T, Wesarg T, Oetting D, Jung L, Williges B. Spatial speech-in-noise performance in simulated single-sided deaf and bimodal cochlear implant users in comparison with real patients. Int J Audiol 2023; 62:30-43. [PMID: 34962428 DOI: 10.1080/14992027.2021.2015633] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 11/30/2021] [Accepted: 12/03/2021] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Speech reception thresholds (SRTs) in spatial scenarios were measured in simulated cochlear implant (CI) listeners with either contralateral normal hearing, or aided hearing impairment (bimodal), and compared to SRTs of real patients, who were measured using the exact same paradigm, to assess goodness of simulation. DESIGN CI listening was simulated using a vocoder incorporating actual CI signal processing and physiologic details of electric stimulation on one side. Unprocessed signals or simulation of aided moderate or profound hearing impairment was used contralaterally. Three spatial speech-in-noise scenarios were tested using virtual acoustics to assess spatial release from masking (SRM) and combined benefit. STUDY SAMPLE Eleven normal-hearing listeners participated in the experiment. RESULTS For contralateral normal and aided moderately impaired hearing, bilaterally assessed SRTs were not statistically different from unilateral SRTs of the better ear, indicating "better-ear-listening". Combined benefit was only found for contralateral profound impaired hearing. As in patients, SRM was highest for contralateral normal hearing and decreased systematically with more severe simulated impairment. Comparison to actual patients showed good reproduction of SRTs, SRM, and better-ear-listening. CONCLUSIONS The simulations reproduced better-ear-listening as in patients and suggest that combined benefit in spatial scenes predominantly occurs when both ears show poor speech-in-noise performance.
Collapse
Affiliation(s)
- Tim Jürgens
- Institute of Acoustics, University of Applied Sciences Lübeck, Lübeck, Germany
- Medical Physics and Cluster of Excellence "Hearing4all", Carl-von-Ossietzky University, Oldenburg, Germany
| | - Thomas Wesarg
- Faculty of Medicine, Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, University of Freiburg, Freiburg, Germany
| | | | - Lorenz Jung
- Faculty of Medicine, Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, University of Freiburg, Freiburg, Germany
| | - Ben Williges
- Medical Physics and Cluster of Excellence "Hearing4all", Carl-von-Ossietzky University, Oldenburg, Germany
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
| |
Collapse
|
12
|
Biever A, Kelsall DC, Lupo JE, Haase GM. Evolution of the candidacy requirements and patient perioperative assessment protocols for cochlear implantation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:3346. [PMID: 36586869 DOI: 10.1121/10.0016446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Cochlear implantation as an approved clinical therapy ushered in an exciting era of innovation for the treatment of hearing loss. The U.S. Food and Drug Administration approved the use of cochlear implants as a treatment option for adults with profound sensorineural hearing loss in 1985. The landscape for treating adults and children with significant hearing loss has changed dramatically over the last three decades. The purpose of this paper is to examine the evolving regulatory process and changes to clinical care. A significant emerging trend in cochlear implantation is the consideration of steroids to preserve hearing during and following surgery. This parallels the quest for hearing preservation in noise-induced hearing disorders, especially considering the current interest in biological drug therapies in this population. The future will likely usher in an era of combination therapeutics utilizing drugs and cochlear implantation. For over 30+ years and following regulatory compliance, the Rocky Mountain Ear Center has developed an extensive candidacy and outcome assessment protocol. This systematic approach evaluates both unaided and aided auditory performance during candidacy stages and post-implantation. Adjunctive measures of cognition and quality-of-life augment the auditory assessment in specific populations. Practical insights into lessons learned have directed further clinical research and have resulted in beneficial changes to clinical care.
Collapse
Affiliation(s)
- Allison Biever
- Rocky Mountain Ear Center, Englewood, Colorado 80113, USA
| | | | - J Eric Lupo
- Rocky Mountain Ear Center, Englewood, Colorado 80113, USA
| | - Gerald M Haase
- University of Colorado, School of Medicine, Aurora, Colorado 80045, USA
| |
Collapse
|
13
|
Smith S. Translational Applications of Machine Learning in Auditory Electrophysiology. Semin Hear 2022; 43:240-250. [PMID: 36313047 PMCID: PMC9605807 DOI: 10.1055/s-0042-1756166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Machine learning (ML) is transforming nearly every aspect of modern life including medicine and its subfields, such as hearing science. This article presents a brief conceptual overview of selected ML approaches and describes how these techniques are being applied to outstanding problems in hearing science, with a particular focus on auditory evoked potentials (AEPs). Two vignettes are presented in which ML is used to analyze subcortical AEP data. The first vignette demonstrates how ML can be used to determine if auditory learning has influenced auditory neurophysiologic function. The second vignette demonstrates how ML analysis of AEPs may be useful in determining whether hearing devices are optimized for discriminating speech sounds.
Collapse
Affiliation(s)
- Spencer Smith
- Department of Speech, Language, and Hearing Sciences, University of Texas at Austin, Austin, Texas
| |
Collapse
|
14
|
Holder JT, Holcomb MA, Snapp H, Labadie RF, Vroegop J, Rocca C, Elgandy MS, Dunn C, Gifford RH. Guidelines for Best Practice in the Audiological Management of Adults Using Bimodal Hearing Configurations. OTOLOGY & NEUROTOLOGY OPEN 2022; 2:e011. [PMID: 36274668 PMCID: PMC9581116 DOI: 10.1097/ono.0000000000000011] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Clinics are treating a growing number of patients with greater amounts of residual hearing. These patients often benefit from a bimodal hearing configuration in which acoustic input from a hearing aid on 1 ear is combined with electrical stimulation from a cochlear implant on the other ear. The current guidelines aim to review the literature and provide best practice recommendations for the evaluation and treatment of individuals with bilateral sensorineural hearing loss who may benefit from bimodal hearing configurations. Specifically, the guidelines review: benefits of bimodal listening, preoperative and postoperative cochlear implant evaluation and programming, bimodal hearing aid fitting, contralateral routing of signal considerations, bimodal treatment for tinnitus, and aural rehabilitation recommendations.
Collapse
Affiliation(s)
| | | | | | | | | | - Christine Rocca
- Guy’s and St. Thomas’ Hearing Implant Centre, London, United Kingdom
| | | | | | | |
Collapse
|
15
|
Smeal M, Snapp H, Ausili S, Holcomb M, Prentiss S. Effects of Bilateral Cochlear Implantation on Binaural Listening Tasks for Younger and Older Adults. Audiol Neurootol 2022; 27:377-387. [PMID: 35636400 DOI: 10.1159/000523914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 02/24/2022] [Indexed: 11/19/2022] Open
Abstract
PURPOSE This study investigated the objective and subjective benefit of a second cochlear implant (CI) on binaural listening tasks of speech understanding in noise and localization in younger and older adults. We aimed to determine if the aging population can utilize binaural cues and obtain comparable benefits from bilateral CI (BIL_CI) when compared to the younger population. METHODS Twenty-nine adults with severe to profound bilateral sensorineural hearing loss were included. Participants were evaluated in two conditions, better CI (BE_CI) alone and BIL_CI using AzBio and Bamford-Kowal-Bench (BKB) sentence in noise tests. Localization tasks were completed in the BIL_CI condition using a broadband stimulus, low-frequency stimuli, and high-frequency stimuli. A subjective questionnaire was administered to assess satisfaction with CI. RESULTS Older age was significantly associated with poorer performance on AzBio +5 dB signal-to-noise ratio (SNR) and BKB-speech in noise (SIN); however, improvements from BE_CI to BIL_CI were observed across all ages. In the AzBio +5 condition, nearly half of all participants achieved a significant improvement from BE_CI to BIL_CI with the majority of those occurring in patients younger than 65 years of age. Conversely, the majority of participants who achieved a significant improvement in BKB-SIN were adults >65 years of age. Years of BIL_CI experience and time between implants were not associated with performance. For localization, mean absolute error increased with age for low and high narrowband noise, but not for the broadband noise. Response gain was negatively correlated with age for all localization stimuli. Neither BIL_CI listening experience nor time between implants significantly impacted localization ability. Subjectively, participants report reduction in disability with the addition of the second CI. There is no observed relationship between age or speech recognition score and satisfaction with BIL_CI. CONCLUSION Overall performance on binaural listening tasks was poorer in older adults than in younger adults. However, older adults were able to achieve significant benefit from the addition of a second CI, and performance on binaural tasks was not correlated with overall device satisfaction. The significance of the improvement was task and stimulus dependent but suggested a critical limit may exist for optimal performance on SIN tasks for CI users. Specifically, older adults require at least a +8 dB SNR to understand 50% of speech postoperatively; therefore, solely utilizing a fixed +5 dB SNR preoperatively to qualify CI candidates is not recommended as this test condition may introduce limitations in demonstrating CI benefit.
Collapse
Affiliation(s)
- Molly Smeal
- Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Hillary Snapp
- Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Sebastian Ausili
- Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Meredith Holcomb
- Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Sandra Prentiss
- Department of Otolaryngology, University of Miami, Miami, Florida, USA
| |
Collapse
|
16
|
Tawdrous MM, D'Onofrio KL, Gifford R, Picou EM. Emotional Responses to Non-Speech Sounds for Hearing-aid and Bimodal Cochlear-Implant Listeners. Trends Hear 2022; 26:23312165221083091. [PMID: 35435773 PMCID: PMC9019384 DOI: 10.1177/23312165221083091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 12/19/2021] [Accepted: 02/06/2022] [Indexed: 02/03/2023] Open
Abstract
The purpose of this project was to evaluate differences between groups and device configurations for emotional responses to non-speech sounds. Three groups of adults participated: 1) listeners with normal hearing with no history of device use, 2) hearing aid candidates with or without hearing aid experience, and 3) bimodal cochlear-implant listeners with at least 6 months of implant use. Participants (n = 18 in each group) rated valence and arousal of pleasant, neutral, and unpleasant non-speech sounds. Listeners with normal hearing rated sounds without hearing devices. Hearing aid candidates rated sounds while using one or two hearing aids. Bimodal cochlear-implant listeners rated sounds while using a hearing aid alone, a cochlear implant alone, or the hearing aid and cochlear implant simultaneously. Analysis revealed significant differences between groups in ratings of pleasant and unpleasant stimuli; ratings from hearing aid candidates and bimodal cochlear-implant listeners were less extreme (less pleasant and less unpleasant) than were ratings from listeners with normal hearing. Hearing aid candidates' ratings were similar with one and two hearing aids. Bimodal cochlear-implant listeners' ratings of valence were higher (more pleasant) in the configuration without a hearing aid (implant only) than in the two configurations with a hearing aid (alone or with an implant). These data support the need for further investigation into hearing device optimization to improve emotional responses to non-speech sounds for adults with hearing loss.
Collapse
Affiliation(s)
- Marina M. Tawdrous
- School of Communication Sciences and Disorders, Western University, 1151 Richmond St, London, ON, N6A 3K7
| | - Kristen L. D'Onofrio
- Department of Hearing and Speech Sciences, Graduate School, Vanderbilt University, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
- Department of Hearing and Speech Sciences, School of Medicine, Vanderbilt University Medical
Center, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
| | - René Gifford
- Department of Hearing and Speech Sciences, Graduate School, Vanderbilt University, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
- Department of Hearing and Speech Sciences, School of Medicine, Vanderbilt University Medical
Center, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
| | - Erin M. Picou
- Department of Hearing and Speech Sciences, Graduate School, Vanderbilt University, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
- Department of Hearing and Speech Sciences, School of Medicine, Vanderbilt University Medical
Center, 1215 21st Ave South, Room 8310, Nashville, TN, 37232
| |
Collapse
|
17
|
Yoon YS. Effect of the Target and Conflicting Frequency and Time Ranges on Consonant Enhancement in Normal-Hearing Listeners. Front Psychol 2021; 12:733100. [PMID: 34867614 PMCID: PMC8634346 DOI: 10.3389/fpsyg.2021.733100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 10/11/2021] [Indexed: 11/29/2022] Open
Abstract
In this paper, the effects of intensifying useful frequency and time regions (target frequency and time ranges) and the removal of detrimental frequency and time regions (conflicting frequency and time ranges) for consonant enhancement were determined. Thirteen normal-hearing (NH) listeners participated in two experiments. In the first experiment, the target and conflicting frequency and time ranges for each consonant were identified under a quiet, dichotic listening condition by analyzing consonant confusion matrices. The target frequency range was defined as the frequency range that provided the highest performance and was decreased 40% from the peak performance from both high-pass filtering (HPF) and low-pass filtering (LPF) schemes. The conflicting frequency range was defined as the frequency range that yielded the peak errors of the most confused consonants and was 20% less than the peak error from both filtering schemes. The target time range was defined as a consonant segment that provided the highest performance and was decreased 40% from that peak performance when the duration of the consonant was systematically truncated from the onset. The conflicting time ranges were defined on the coincided target time range because, if they temporarily coincide, the conflicting frequency ranges would be the most detrimental factor affecting the target frequency ranges. In the second experiment, consonant recognition was binaurally measured in noise under three signal processing conditions: unprocessed, intensified target ranges by a 6-dB gain (target), and combined intensified target and removed conflicting ranges (target-conflicting). The results showed that consonant recognition improved significantly with the target condition but greatly deteriorated with a target-conflicting condition. The target condition helped transmit voicing and manner cues while the target-conflicting condition limited the transmission of these cues. Confusion analyses showed that the effect of the signal processing on consonant improvement was consonant-specific: the unprocessed condition was the best for /da, pa, ma, sa/; the target condition was the best for /ga, fa, va, za, ʒa/; and the target-conflicting condition was the best for /na, ʃa/. Perception of /ba, ta, ka/ was independent of the signal processing. The results suggest that enhancing the target ranges is an efficient way to improve consonant recognition while the removal of conflicting ranges negatively impacts consonant recognition.
Collapse
Affiliation(s)
- Yang-Soo Yoon
- Laboratory of Translational Auditory Research, Department of Communication Sciences and Disorders, Baylor University, Waco, TX, United States
| |
Collapse
|
18
|
Arweiler-Harbeck D, D'heygere V, Meyer M, Hans S, Waschkies L, Lang S, Anton K, Hessel H, Schneider A, Heiler T, Höing B. Digital Live Imaging of Intraoperative Electrocochleography - First Description of Feasibility and Hearing Preservation During Cochlear Implantation. Otol Neurotol 2021; 42:1342-1346. [PMID: 34369444 DOI: 10.1097/mao.0000000000003256] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Intraoperative electrocochleography (ECochG) during cochlear implantation is a promising tool to preserve residual hearing. However, the time gap between insertion of the electrode and acoustic feedback from the audiologist to the surgeon can cause delay and subsequently irreparable damage to cochlear structures. In this feasibility study, for the first time, real-time visualization of intraoperative ECochG via digital microscope display directly to the surgeon was successfully performed in four patients. MATERIALS AND METHODS Four patients with residual hearing underwent cochlear implantation. Intraoperative electrocochleography responses were collected and direct visualization during the time of electrode insertion into the surgeon's field of view in the binoculars using augmented real-time digital imaging was realized. The time of electrode insertion was recorded. Hearing preservation was determined by testing postoperative changes in behavioral thresholds. RESULTS Digital live visualization of intraoperative ECochG using image augmentation in a digital microscope was successfully performed in all cases and enabled direct adaptation of the surgeon's insertion behavior. Mean time of electrode insertion was 129.8 seconds. Postoperative behavioral thresholds were comparable to preoperative taken thresholds. Preservation of residual hearing in the low frequency range was possible. DISCUSSION This study is the first to describe digital visualization of intraoperative electrocochleography as a new method enabling the surgeon to directly react to changes in amplitude of the cochlea microphonics. Our results show that augmentation of the intraoperative live imaging with electrical potentials could add to hearing preservation during cochlear implantation.
Collapse
Affiliation(s)
- Diana Arweiler-Harbeck
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | - Victoria D'heygere
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | - Moritz Meyer
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | - Stefan Hans
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | - Laura Waschkies
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | - Stephan Lang
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| | | | | | | | | | - Benedikt Höing
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University Duisburg-Essen, Essen
| |
Collapse
|
19
|
Abstract
OBJECTIVES The purpose of this study was to examine current cochlear implant (CI) billing practices across CI audiologists in the United States, to determine if CI audiologists are following the National Correct Coding Initiative (NCCI) edits, and to assess the CI audiologist's exposure to billing education. DESIGN A 48-question survey was electronically distributed to and completed by audiologists who bill for CI services. Demographic data including work setting, population served, years of experience, number of CI patients managed per week, and exposure to billing education were collected. Data were analyzed to identify codes and modifiers used to bill for commonly performed CI procedures such as unilateral and bilateral CI programming, preoperative and postoperative testing, and objective measures. RESULTS Data were obtained from 96 audiologists. The majority (86.3%, n = 82) of respondents agreed or strongly agreed they understand billing and coding practices for cochlear implants and 94.7% (n = 89) rated themselves as somewhat to highly efficient when performing these practices. Only 16.8% (n = 16) of respondents reported receiving formal training for practice management, and half of the respondents (51.1%, n = 48) reported unfamiliarity with national billing guidelines. Those who received formal training reported higher billing efficiency. Wide variability was seen for various billing scenarios. Billing questions were presented, and answers were coded as correct or incorrect based on the NCCI edits. Respondents who reported higher agreement with understanding billing and who received formal training scored better on common billing questions related to the NCCI edits. CONCLUSIONS Most CI audiologists rated themselves as efficient in billing; however, wide variance in billing practices was observed. Incorporating practice management and current billing education into daily practice and into audiology training programs is essential to clinic efficiency, practice management, and CI program viability. CI audiologists should be knowledgeable about appropriate billing practices to ensure long-term sustainability of programs.
Collapse
|
20
|
Agrawal S, Coulthurst S, Nachman A, Koka K, Murray M. Acoustic component programming in children with cochlear implants using electrocochleography. Int J Audiol 2021; 61:736-743. [PMID: 34355617 DOI: 10.1080/14992027.2021.1917779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Objective measurements improve reliability and effectiveness of hearing assessment and cochlear implant (CI) programming in young children. In CI recipients with acoustic hearing in the implanted ear, electrocochleography (ECochG) can be conducted using intracochlear electrodes. The cochlear microphonic (CM) portion of ECochG has been shown to correlate with pure-tone audiometric thresholds in adult and paediatric CI recipients. Our goal was to determine if ECochG thresholds can be used to appropriately fit the acoustic component to the implanted ear in children. DESIGN Prospective. STUDY SAMPLE Eight children (aged 3.5-15.5 years, 10 ears) implanted with Advanced Bionics HiFocus Mid-Scala electrode array were recruited. CI ear acoustic thresholds were measured behaviourally and via ECochG. Two acoustic component enabled CI programs were created using the two sets of thresholds. Age and language appropriate speech outcomes and subjective feedback were obtained. RESULTS Speech scores were equivalent with the behavioural and ECochG thresholds programs. Subjectively, the ECochG thresholds program was preferred by 7/8 subjects. One subject preferred to use an electric only program. CONCLUSION Our data suggest that ECochG thresholds can be used to supplement the behavioural clinical methods and aid the reliable fitting of the acoustic component in paediatric CI recipients.
Collapse
|
21
|
Hartling CL, Fowler JR, Stark GN, Glickman B, Eddolls M, Oh Y, Ramsey K, Reiss LAJ. Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants. Ear Hear 2021; 41:1545-1559. [PMID: 33136630 PMCID: PMC9014818 DOI: 10.1097/aud.0000000000000874] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 to 4 octaves are fused across ears, leading to spectral averaging and speech perception interference. The main goal of this study was to measure binaural pitch fusion in children with different hearing device combinations and compare results across groups and with adults. A second goal was to examine the relationship of binaural pitch fusion to interaural pitch differences or pitch match range, a measure of sequential pitch discriminability. DESIGN Binaural pitch fusion was measured in children between the ages of 6.1 and 11.1 years with bilateral HAs (n = 9), bimodal CI (n = 10), bilateral CIs (n = 17), as well as normal-hearing (NH) children (n = 21). Depending on device combination, stimuli were pure tones or electric pulse trains delivered to individual electrodes. Fusion ranges were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus to find the range that fused with the reference stimulus. Interaural pitch match functions were measured using sequential presentation of reference and comparison stimuli, and varying the comparison stimulus to find the pitch match center and range. RESULTS Children with bilateral HAs had significantly broader binaural pitch fusion than children with NH, bimodal CI, or bilateral CIs. Children with NH and bilateral HAs, but not children with bimodal or bilateral CIs, had significantly broader fusion than adults with the same hearing status and device configuration. In children with bilateral CIs, fusion range was correlated with several variables that were also correlated with each other: pure-tone average in the second implanted ear before CI, and duration of prior bilateral HA, bimodal CI, or bilateral CI experience. No relationship was observed between fusion range and pitch match differences or range. CONCLUSIONS The findings suggest that binaural pitch fusion is still developing in this age range and depends on hearing device combination but not on interaural pitch differences or discriminability.
Collapse
Affiliation(s)
- Curtis L Hartling
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Jennifer R Fowler
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Gemaine N Stark
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Bess Glickman
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Morgan Eddolls
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Yonghee Oh
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| | - Katrina Ramsey
- Biostatistics and Design Program, Oregon Health and Science University, Portland, Oregon, USA
| | - Lina A J Reiss
- Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA
| |
Collapse
|
22
|
D'Onofrio KL, Gifford RH. Bimodal Benefit for Music Perception: Effect of Acoustic Bandwidth. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2021; 64:1341-1353. [PMID: 33784471 PMCID: PMC8608177 DOI: 10.1044/2020_jslhr-20-00390] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 10/15/2020] [Accepted: 12/04/2020] [Indexed: 05/29/2023]
Abstract
Purpose The challenges associated with cochlear implant (CI)-mediated listening are well documented; however, they can be mitigated through the provision of aided acoustic hearing in the contralateral ear-a configuration termed bimodal hearing. This study extends previous literature to examine the effect of acoustic bandwidth in the non-CI ear for music perception. The primary aim was to determine the minimum and optimum acoustic bandwidth necessary to obtain bimodal benefit for music perception and speech perception. Method Participants included 12 adult bimodal listeners and 12 adult control listeners with normal hearing. Music perception was assessed via measures of timbre perception and subjective sound quality of real-world music samples. Speech perception was assessed via monosyllabic word recognition in quiet. Acoustic stimuli were presented to the non-CI ear in the following filter conditions: < 125, < 250, < 500, and < 750 Hz, and wideband (full bandwidth). Results Generally, performance for all stimuli improved with increasing acoustic bandwidth; however, the bandwidth that is both minimally and optimally beneficial may be dependent upon stimulus type. On average, music sound quality required wideband amplification, whereas speech recognition with a male talker in quiet required a narrower acoustic bandwidth (< 250 Hz) for significant benefit. Still, average speech recognition performance continued to improve with increasing bandwidth. Conclusion Further research is warranted to examine optimal acoustic bandwidth for additional stimulus types; however, these findings indicate that wideband amplification is most appropriate for speech and music perception in individuals with bimodal hearing.
Collapse
Affiliation(s)
- Kristen L D'Onofrio
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
23
|
Sargsyan G, Kanaan N, Lenarz T, Lesinski-Schiedat A. Comparison of speech recognition in cochlear implant patients with and without residual hearing: A review of indications. Cochlear Implants Int 2021; 22:257-264. [PMID: 33740882 DOI: 10.1080/14670100.2021.1898111] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE This study evaluated existing guidelines for cochlear implantation (CI) according to the residual hearing of the patient. Speech recognition performance of adults implanted according to their degree of residual hearing was retrospectively evaluated. METHODS Speech recognition results of 174 adult cochlear implant recipients were analyzed. All participants had pure tone thresholds of >75 dB at 2 and 4 kHz and were divided into three groups based on differing levels of low-frequency residual hearing. RESULTS Findings indicate that CI was of benefit for all patients with bilateral severe hearing loss and patients with nonfunctional residual hearing both in quiet and noisy conditions. Patients with residual low-frequency hearing could benefit from combined electro-acoustic stimulation compared to CI alone or to hearing aids alone preoperatively. The speech recognition performance of all CI recipients with different levels of residual hearing in the low frequencies was similar except that superior performance was observed in the group using electro-acoustic stimulation compared to electrical stimulation alone. DISCUSSION AND CONCLUSIONS Study results demonstrate the success of CI in accordance with current guidelines and also support expanding implantation guidelines to include patients who have severe-to-profound high-frequency sensorineural hearing loss and usable residual low frequency hearing.
Collapse
Affiliation(s)
- Gayane Sargsyan
- ENT-Department, YSMU, Yerevan, Armenia.,Department of Otorhinolaryngology, Medical University of Hannover (MHH), Hannover, Germany
| | - Natalie Kanaan
- Department of Otorhinolaryngology, Medical University of Hannover (MHH), Hannover, Germany.,Praxis, Osnabrueck, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Medical University of Hannover (MHH), Hannover, Germany
| | | |
Collapse
|
24
|
Wang NYH, Wang HLS, Wang TW, Fu SW, Lu X, Wang HM, Tsao Y. Improving the Intelligibility of Speech for Simulated Electric and Acoustic Stimulation Using Fully Convolutional Neural Networks. IEEE Trans Neural Syst Rehabil Eng 2020; 29:184-195. [PMID: 33275585 DOI: 10.1109/tnsre.2020.3042655] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Combined electric and acoustic stimulation (EAS) has demonstrated better speech recognition than conventional cochlear implant (CI) and yielded satisfactory performance under quiet conditions. However, when noise signals are involved, both the electric signal and the acoustic signal may be distorted, thereby resulting in poor recognition performance. To suppress noise effects, speech enhancement (SE) is a necessary unit in EAS devices. Recently, a time-domain speech enhancement algorithm based on the fully convolutional neural networks (FCN) with a short-time objective intelligibility (STOI)-based objective function (termed FCN(S) in short) has received increasing attention due to its simple structure and effectiveness of restoring clean speech signals from noisy counterparts. With evidence showing the benefits of FCN(S) for normal speech, this study sets out to assess its ability to improve the intelligibility of EAS simulated speech. Objective evaluations and listening tests were conducted to examine the performance of FCN(S) in improving the speech intelligibility of normal and vocoded speech in noisy environments. The experimental results show that, compared with the traditional minimum-mean square-error SE method and the deep denoising autoencoder SE method, FCN(S) can obtain better gain in the speech intelligibility for normal as well as vocoded speech. This study, being the first to evaluate deep learning SE approaches for EAS, confirms that FCN(S) is an effective SE approach that may potentially be integrated into an EAS processor to benefit users in noisy environments.
Collapse
|
25
|
Kessler DM, Ananthakrishnan S, Smith SB, D'Onofrio K, Gifford RH. Frequency Following Response and Speech Recognition Benefit for Combining a Cochlear Implant and Contralateral Hearing Aid. Trends Hear 2020; 24:2331216520902001. [PMID: 32003296 PMCID: PMC7257083 DOI: 10.1177/2331216520902001] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Multiple studies have shown significant speech recognition benefit when acoustic hearing is combined with a cochlear implant (CI) for a bimodal hearing configuration. However, this benefit varies greatly between individuals. There are few clinical measures correlated with bimodal benefit and those correlations are driven by extreme values prohibiting data-driven, clinical counseling. This study evaluated the relationship between neural representation of fundamental frequency (F0) and temporal fine structure via the frequency following response (FFR) in the nonimplanted ear as well as spectral and temporal resolution of the nonimplanted ear and bimodal benefit for speech recognition in quiet and noise. Participants included 14 unilateral CI users who wore a hearing aid (HA) in the nonimplanted ear. Testing included speech recognition in quiet and in noise with the HA-alone, CI-alone, and in the bimodal condition (i.e., CI + HA), measures of spectral and temporal resolution in the nonimplanted ear, and FFR recording for a 170-ms/da/stimulus in the nonimplanted ear. Even after controlling for four-frequency pure-tone average, there was a significant correlation (r = .83) between FFR F0 amplitude in the nonimplanted ear and bimodal benefit. Other measures of auditory function of the nonimplanted ear were not significantly correlated with bimodal benefit. The FFR holds potential as an objective tool that may allow data-driven counseling regarding expected benefit from the nonimplanted ear. It is possible that this information may eventually be used for clinical decision-making, particularly in difficult-to-test populations such as young children, regarding effectiveness of bimodal hearing versus bilateral CI candidacy.
Collapse
Affiliation(s)
- David M Kessler
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | | | - Spencer B Smith
- Department of Communication Sciences and Disorders, The University of Texas at Austin, TX, USA
| | - Kristen D'Onofrio
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.,Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| |
Collapse
|
26
|
The Temporal Fine Structure of Background Noise Determines the Benefit of Bimodal Hearing for Recognizing Speech. J Assoc Res Otolaryngol 2020; 21:527-544. [PMID: 33104927 PMCID: PMC7644728 DOI: 10.1007/s10162-020-00772-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 10/14/2020] [Indexed: 01/01/2023] Open
Abstract
Cochlear implant (CI) users have more difficulty understanding speech in temporally modulated noise than in steady-state (SS) noise. This is thought to be caused by the limited low-frequency information that CIs provide, as well as by the envelope coding in CIs that discards the temporal fine structure (TFS). Contralateral amplification with a hearing aid, referred to as bimodal hearing, can potentially provide CI users with TFS cues to complement the envelope cues provided by the CI signal. In this study, we investigated whether the use of a CI alone provides access to only envelope cues and whether acoustic amplification can provide additional access to TFS cues. To this end, we evaluated speech recognition in bimodal listeners, using SS noise and two amplitude-modulated noise types, namely babble noise and amplitude-modulated steady-state (AMSS) noise. We hypothesized that speech recognition in noise depends on the envelope of the noise, but not on its TFS when listening with a CI. Secondly, we hypothesized that the amount of benefit gained by the addition of a contralateral hearing aid depends on both the envelope and TFS of the noise. The two amplitude-modulated noise types decreased speech recognition more effectively than SS noise. Against expectations, however, we found that babble noise decreased speech recognition more effectively than AMSS noise in the CI-only condition. Therefore, we rejected our hypothesis that TFS is not available to CI users. In line with expectations, we found that the bimodal benefit was highest in babble noise. However, there was no significant difference between the bimodal benefit obtained in SS and AMSS noise. Our results suggest that a CI alone can provide TFS cues and that bimodal benefits in noise depend on TFS, but not on the envelope of the noise.
Collapse
|
27
|
Effects of noise on integration of acoustic and electric hearing within and across ears. PLoS One 2020; 15:e0240752. [PMID: 33057396 PMCID: PMC7561114 DOI: 10.1371/journal.pone.0240752] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 10/01/2020] [Indexed: 11/19/2022] Open
Abstract
In bimodal listening, cochlear implant (CI) users combine electric hearing (EH) in one ear and acoustic hearing (AH) in the other ear. In electric-acoustic stimulation (EAS), CI users combine EH and AH in the same ear. In quiet, integration of EH and AH has been shown to be better with EAS, but with greater sensitivity to tonotopic mismatch in EH. The goal of the present study was to evaluate how external noise might affect integration of AH and EH within or across ears. Recognition of monosyllabic words was measured for normal-hearing subjects listening to simulations of unimodal (AH or EH alone), EAS, and bimodal listening in quiet and in speech-shaped steady noise (10 dB, 0 dB signal-to-noise ratio). The input/output frequency range for AH was 0.1–0.6 kHz. EH was simulated using an 8-channel noise vocoder. The output frequency range was 1.2–8.0 kHz to simulate a shallow insertion depth. The input frequency range was either matched (1.2–8.0 kHz) or mismatched (0.6–8.0 kHz) to the output frequency range; the mismatched input range maximized the amount of speech information, while the matched input resulted in some speech information loss. In quiet, tonotopic mismatch differently affected EAS and bimodal performance. In noise, EAS and bimodal performance was similarly affected by tonotopic mismatch. The data suggest that tonotopic mismatch may differently affect integration of EH and AH in quiet and in noise.
Collapse
|
28
|
The influence of Slim Modiolar electrode on residual hearing in pediatric patients. Eur Arch Otorhinolaryngol 2020; 278:2723-2732. [PMID: 32897440 DOI: 10.1007/s00405-020-06342-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 08/28/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Hearing preservation cochlear implantation is an established procedure in patients with low-frequency residual hearing, especially in pediatric cochlear implantation. More delicate, thin electrode arrays can minimize damage in the inner ear and enhance the possibility for residual hearing preservation. The Cochlear® CI532 electrode has been reported as an electrode with the potential for residual hearing preservation. No similar studies pertaining to hearing preservation in pediatric patients have appeared to date. The aim of this study was to investigate whether the Cochlear® CI532 Slim Modiolar electrode allows the preservation of low-frequency residual hearing in children undergoing cochlear implantation. METHODS In this multicenter, nonrandomized, prospective clinical cohort study, medical data of 14 pediatric patients implanted with the CI532 were collected. All patients had residual low-frequency hearing (preoperative audiogram or ABR with at least one threshold better than 90 dB HL at 125, 250, 500, or 1000 Hz). Postoperative thresholds were obtained 1, 3, 6, and 12 months after cochlear implantation. RESULTS Based on the HEARRING classification, 78.6% of children (11/14) had complete hearing preservation at the last follow-up visit (12 months after CI, or if not available, 6 months). A total of 21.4% (3/14) had partial hearing preservation. At the last follow-up visit, neither minimal hearing preservation nor loss of hearing was observed. Functional low-frequency hearing was preserved in 13 out of 14 patients (93%). CONCLUSIONS The residual hearing preservation results in children were superior to the results previously reported in adults.
Collapse
|
29
|
A Cross-Language Comparison of Sentence Recognition Using American English and Mandarin Chinese HINT and AzBio Sentences. Ear Hear 2020; 42:405-413. [PMID: 32826510 DOI: 10.1097/aud.0000000000000938] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study was to perform a cross-language comparison of two commonly used sentence-recognition materials (i.e., Hearing in Noise Test [HINT] and AzBio) in American English (AE) and Mandarin Chinese (MC). DESIGNS Sixty normal-hearing, native English-speaking and 60 normal-hearing, native Chinese-speaking young adults were recruited to participate in three experiments. In each experiment, the subjects were tested in their native language. In experiments I and II, noise and tone vocoders were used to process the HINT and AzBio sentences, respectively. The number of channels varied from 1 to 9, with an envelope cutoff frequency of 160 Hz. In experiment III, the AE AzBio and the MC HINT sentences were tested in speech-shaped noise at various signal to noise ratios (i.e., -20, -15, -10, -5, and 0 dB). The performance-intensity functions of sentence recognition using the two sets of sentence materials were compared. RESULTS Results of experiments I and II using vocoder processing indicated that the AE and MC versions of HINT and AzBio sentences differed in level of difficulty. The AE version yielded higher recognition performance than the MC version for both HINT and AzBio sentences. The type of vocoder processing (i.e., tone and noise vocoders) produced little differences in sentence-recognition performance in both languages. Incidentally, the AE AzBio sentences and the MC HINT sentences had similar recognition performance under vocoder processing. Such similarity was further confirmed under noise conditions in experiment III, where the performance-intensity functions of the two sets of sentences were closely matched. CONCLUSIONS The HINT and AzBio sentence materials developed in AE and MC differ in level of difficulty. The AE AzBio and the MC HINT sentence materials are similar in level of difficulty. In cross-language comparative research, the MC HINT and the AE AzBio sentences should be chosen for the respective language as the target sentence-recognition test materials.
Collapse
|
30
|
Fletcher MD, Song H, Perry SW. Electro-haptic stimulation enhances speech recognition in spatially separated noise for cochlear implant users. Sci Rep 2020; 10:12723. [PMID: 32728109 PMCID: PMC7391652 DOI: 10.1038/s41598-020-69697-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 07/14/2020] [Indexed: 11/10/2022] Open
Abstract
Hundreds of thousands of profoundly hearing-impaired people perceive sounds through electrical stimulation of the auditory nerve using a cochlear implant (CI). However, CI users are often poor at understanding speech in noisy environments and separating sounds that come from different locations. We provided missing speech and spatial hearing cues through haptic stimulation to augment the electrical CI signal. After just 30 min of training, we found this “electro-haptic” stimulation substantially improved speech recognition in multi-talker noise when the speech and noise came from different locations. Our haptic stimulus was delivered to the wrists at an intensity that can be produced by a compact, low-cost, wearable device. These findings represent a significant step towards the production of a non-invasive neuroprosthetic that can improve CI users’ ability to understand speech in realistic noisy environments.
Collapse
Affiliation(s)
- Mark D Fletcher
- University of Southampton Auditory Implant Service, University of Southampton, University Road, Southampton, SO17 1BJ, UK.
| | - Haoheng Song
- Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, UK
| | - Samuel W Perry
- University of Southampton Auditory Implant Service, University of Southampton, University Road, Southampton, SO17 1BJ, UK
| |
Collapse
|
31
|
General Health Quality of Life Instruments Underestimate the Impact of Bilateral Cochlear Implantation. Otol Neurotol 2020; 40:745-753. [PMID: 31192902 DOI: 10.1097/mao.0000000000002225] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To determine the extent to which bilateral cochlear implantation increases patient-reported benefit as compared with unilateral implantation and no implantation. DATA SOURCES PubMed, Scopus, CINAHL, and Cochrane databases searches were performed using the keywords ("Cochlear Implant" or "Cochlear Implantation") and ("bilateral"). STUDY SELECTION Studies assessing hearing/CI-specific (CI) and general-health-related (HR) quality of life (QOL) in adult patients after bilateral cochlear implantation were included. DATA EXTRACTION Of the 31 articles meeting criteria, usable QOL data were available for 16 articles (n = 355 bilateral CI recipients). DATA SYNTHESIS Standardized mean difference (Δ) for each measure and weighted effects were determined. Meta-analysis was performed for all QOL measures and also independently for hearing/CI-specific QOL and HRQOL. CONCLUSION When measured using hearing/CI-specific QOL instruments, patients reported very large improvements in QOL comparing before cochlear implantation to bilateral CI (Δ=2.07 [1.76-2.38]) and medium improvements comparing unilateral CI to bilateral CI (Δ=0.51 [0.32- 0.71]). Utilization of parallel versus crossover study design did not impact QOL outcomes (χ = 0.512, p = 0.47). No detectable improvements were observed in either CI transition when using HRQOL instruments (no CI to bilateral CI: Δ=0.40 [-0.02 to 0.81]; unilateral CI to bilateral CI: Δ=0.22 [-0.02 to 0.46]).The universal nature of HRQOL instruments may render them insensitive to the medium to large QOL improvements reported by patients using hearing/CI-specific QOL instruments. Given that HRQOL instruments are used to determine the economic benefit of health interventions, these measurement differences suggest that the health economic value of bilateral cochlear implantation has been underestimated.
Collapse
|
32
|
Kessler DM, Wolfe J, Blanchard M, Gifford RH. Clinical Application of Spectral Modulation Detection: Speech Recognition Benefit for Combining a Cochlear Implant and Contralateral Hearing Aid. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2020; 63:1561-1571. [PMID: 32379527 PMCID: PMC7842114 DOI: 10.1044/2020_jslhr-19-00304] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/16/2019] [Accepted: 01/27/2020] [Indexed: 05/29/2023]
Abstract
Purpose The purpose of this study was to investigate the relationship between speech recognition benefit derived from the addition of a hearing aid (HA) to the nonimplanted ear (i.e., bimodal benefit) and spectral modulation detection (SMD) performance in the nonimplanted ear in a large clinical sample. An additional purpose was to investigate the influence of low-frequency pure-tone average (PTA) of the nonimplanted ear and age at implantation on the variance in bimodal benefit. Method Participants included 311 unilateral cochlear implant (CI) users who wore an HA in the nonimplanted ear. Participants completed speech recognition testing in quiet and in noise with the CI-alone and in the bimodal condition (i.e., CI and contralateral HA) and SMD in the nonimplanted ear. Results SMD performance in the nonimplanted ear was significantly correlated with bimodal benefit in quiet and in noise. However, this relationship was much weaker than previous reports with smaller samples. SMD, low-frequency PTA of the nonimplanted ear from 125 to 750 Hz, and age at implantation together accounted for, at most, 19.1% of the variance in bimodal benefit. Conclusions Taken together, SMD, low-frequency PTA, and age at implantation account for the greatest amount of variance in bimodal benefit than each variable alone. A large portion of variance (~80%) in bimodal benefit is not explained by these variables. Supplemental Material https://doi.org/10.23641/asha.12185493.
Collapse
Affiliation(s)
- David M Kessler
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | | | | | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
33
|
The Effect of Cochlear Implant Interval on Spoken Language Skills of Pediatric Bilateral Cochlear Implant Users. Otol Neurotol 2020; 40:e600-e605. [PMID: 31135675 DOI: 10.1097/mao.0000000000002245] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To examine the effects of cochlear implant (CI) interval (time between CI surgeries) on receptive vocabulary and receptive language skills for children with bilateral CIs. STUDY DESIGN A prospective cross-sectional study design. SETTING Participants were recruited from, and tested at, oral schools for the deaf and pediatric audiology clinics across the United States. PATIENTS Eighty-eight children, 4 to 9 years of age, with bilateral CIs and known hearing histories. Twenty-three participants received CIs simultaneously and 65 received CIs sequentially. Of those implanted sequentially, 86% wore a hearing aid (HA) on the non-implanted ear during the CI interval. INTERVENTION Bilateral cochlear implantation. MAIN OUTCOME MEASURES Receptive vocabulary was measured via the Peabody Picture Vocabulary Test (PPVT). Receptive language skills were measured via the Clinical Evaluation of Language Fundamentals (CELF). RESULTS Multiple linear regression models indicate better receptive vocabulary and receptive language skills are associated with earlier ages at first CI (CI 1), but not with shorter CI intervals. CONCLUSIONS Early cochlear implantation (i.e., age at CI 1) is critical for better receptive vocabulary and receptive language skills. Shorter CI intervals are not associated with better receptive vocabulary and receptive language skills for these 88 children, who nearly all used bimodal hearing during the interval. Use of a HA at the non-implanted ear, before receipt of a second CI (CI 2), may mitigate the effects of early bilateral auditory deprivation.
Collapse
|
34
|
Intraoperative Intracochlear Electrocochleography and Residual Hearing Preservation Outcomes When Using Two Types of Slim Electrode Arrays in Cochlear Implantation. Otol Neurotol 2020; 40:S29-S37. [PMID: 31225820 DOI: 10.1097/mao.0000000000002212] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To report residual hearing preservation outcomes in patients with low frequency hearing, after cochlear implant (CI) electrode insertion with two types of electrode arrays: one straight and other perimodiolar, when using intraoperative intracochlear electrocochleography (ECochG) during (CI) electrode insertion. STUDY DESIGN Prospective, randomized study. SETTING Tertiary referral otology center. PATIENTS Fifteen patients ranging from 33 to 54 years old (mean 51.19). They had been diagnosed with a bilateral, profound sensorineural hearing loss and treated with a unilateral cochlear implant: eight of them with the CI532 and seven of them with the CI522 (Cochlear Ltd, Sydney, Australia). INTERVENTION Pure-tone audiometry was performed preoperatively and at 1 and 6 months postoperatively. Interoperatively, intracochlear ECochG was performed using the apical-most electrode. The amplitude of the first harmonic was plotted and monitored in real time by the audiologist-surgeon team during their CI electrode insertion. The different ECoch patterns of the insertion track were recorded and analyzed. RESULTS In 12 cases ECochG responses were successfully recorded. In three cases no ECochG responses could be recorded with no residual hearing observed postoperatively in two of them. With respect to the first harmonic amplitude changes, we found: four cases with an overall increase in amplitude measured from the beginning of insertion until completion, all of them showed residual hearing (<15 dB HL) at 6 months postoperation. Three cases with an increasing amplitude at the beginning of insertion, with a decrease in amplitude as insertion progressed to completion, in two cases dropping of residual hearing (15-30 dB HL) were observed after 6 months postoperation and, in one case, complete residual hearing was observed at 6 months postoperatively. And finally five cases presented amplitudes at the start of insertion with modifications of amplitude during the insertion dynamic, with increasing and descending in amplitude range during the whole insertion, two of them showed residual hearing at 6 months postoperation and three cases a drop of residual hearing (15-30 dB HL) was observed after 6 months postoperation. No statistical differences between CI532 and CI522 electrodes were found. Data of the ECochG responses are also presented (p value ≥ 0.05). CONCLUSION ECochG is a useful tool to evaluate the residual hearing in CI patients with straight and perimodiolar cochlear implant. More studies are needed to fully understand the relationship between ECochG and the presence of residual hearing, cochlear trauma, and functional outcomes.
Collapse
|
35
|
The Cost-Effectiveness of Bimodal Stimulation Compared to Unilateral and Bilateral Cochlear Implant Use in Adults with Bilateral Severe to Profound Deafness. Ear Hear 2020; 40:1425-1436. [PMID: 30998548 DOI: 10.1097/aud.0000000000000727] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES An increasing number of severe-profoundly deaf adult unilateral cochlear implant (CI) users receive bimodal stimulation; that is, they use a conventional acoustic hearing aid (HA) in their nonimplanted ear. The combination of electric and contralateral acoustic hearing provides additional benefits to hearing and also to general health-related quality of life compared with unilateral CI use. Bilateral CI is a treatment alternative to both unilateral CI and bimodal stimulation in some healthcare systems. The objective of this study was to conduct an economic evaluation of bimodal stimulation compared with other management options for adults with bilateral severe to profound deafness. DESIGN The economic evaluation took the form of a cost-utility analysis and compared bimodal stimulation (CI+HA) to two treatment alternatives: unilateral and bilateral CI. The analysis used a public healthcare system perspective based on data from the United Kingdom and the United States. Costs and health benefits were identified for both alternatives and estimated across a patient's lifetime using Markov state transition models. Utilities were based on Health Utilities Index estimates, and health outcomes were expressed in Quality Adjusted Life Years (QALYs). The results were presented using the Incremental Cost-Effectiveness Ratio and the Net Monetary Benefit approach to determine the cost-effectiveness of bimodal stimulation. Probabilistic sensitivity analyses explored the degree of overall uncertainty using Monte Carlo simulation. Deterministic sensitivity analyses and analysis of covariance identified parameters to which the model was most sensitive; that is, whose values had a strong influence on the intervention that was determined to be most cost-effective. A value of information analysis was performed to determine the potential value to be gained from additional research on bimodal stimulation. RESULTS The base case model showed that bimodal stimulation was the most cost-effective treatment option with a decision certainty of 72 and 67% in the United Kingdom and United States, respectively. Despite producing more QALYs than either unilateral CI or bimodal stimulation, bilateral CI was found not to be cost-effective because it was associated with excessive costs. Compared with unilateral CI, the increased costs of bimodal stimulation were outweighed by the gain in quality of life. Bimodal stimulation was found to cost an extra £174 per person in the United Kingdom ($937 in the US) and yielded an additional 0.114 QALYs compared with unilateral CI, resulting in an Incremental Cost-Effectiveness Ratio of £1521 per QALY gained in the United Kingdom ($8192/QALY in the United States). The most influential variable was the utility gained from the simultaneous use of both devices (CI+HA) compared with Unilateral CI. The value of further research was £4,383,922 at £20,000/QALY ($86,955,460 at $50,000/QALY in the United States). CONCLUSIONS This study provides evidence of the most cost-effective treatment alternative for adults with bilateral severe to profound deafness from publicly funded healthcare perspectives of the United Kingdom and United States. Bimodal stimulation was found to be more cost-effective than unilateral and bilateral CI across a wide range of willingness-to-pay thresholds. If there is scope for future research, conducting interventional designs to obtain utilities for bimodal stimulation compared with unilateral CI would reduce decision uncertainty considerably.
Collapse
|
36
|
Morrel WG, Holder JT, Dawant BM, Noble JH, Labadie RF. Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes. Otolaryngol Head Neck Surg 2020; 162:718-724. [PMID: 32093543 DOI: 10.1177/0194599820904941] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Studies suggest lateral wall (LW) scala tympani (ST) height decreases apically, which may limit insertion depth. No studies have investigated the relationship of LW ST height with translocation rate or location. STUDY DESIGN Retrospective review. SETTING Cochlear implant program at tertiary referral center. SUBJECTS AND METHODS LW ST height was measured in preoperative images for patients with straight electrodes. Scalar location, angle of insertion depth (AID), and translocation depth were measured in postoperative images. Audiologic outcomes were tracked. RESULTS In total, 177 ears were identified with 39 translocations (22%). Median AID was 443° (interquartile range [IQR], 367°-550°). Audiologic outcomes (126 ears) showed a small, significant correlation between consonant-nucleus-consonant (CNC) word score and AID (r = 0.20, P = .027), although correlation was insignificant if translocation occurred (r = 0.11, P = .553). Translocation did not affect CNC score (P = .335). AID was higher for translocated electrodes (503° vs 445°, P = .004). Median translocation depth was 381° (IQR, 222°-399°). Median depth at which a 0.5-mm electrode would not fit within 0.1 mm of LW was 585° (IQR, 405°-585°). Median depth at which a 0.5-mm electrode would displace the basilar membrane by ≥0.1 mm was 585° (IQR, 518°-765°); this was defined as predicted translocation depth (PTD). Translocation rate was 39% for insertions deeper than PTD and 14% for insertions shallower than PTD (P = .008). CONCLUSION AID and CNC are directly correlated for straight electrodes when not translocated. Translocations generally occur around 380° and are more common with deeper insertions due to decreasing LW ST height. Risk of translocation increases significantly after 580°.
Collapse
Affiliation(s)
- William G Morrel
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| |
Collapse
|
37
|
McRackan TR, Hand BN, Velozo CA, Dubno JR. Association of Demographic and Hearing-Related Factors With Cochlear Implant-Related Quality of Life. JAMA Otolaryngol Head Neck Surg 2020; 145:422-430. [PMID: 30896742 DOI: 10.1001/jamaoto.2019.0055] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Only limited evidence is available describing the contribution of patient-related factors to quality of life in adults with cochlear implants. Objective Assess the association between demographic, hearing-related, and cochlear implant-related factors and quality of life by using a new Cochlear Implant Quality of Life (CIQOL) item bank, which was developed to meet rigorous psychometric standards. Design, Setting, and Participants Multicenter cross-sectional study of adults 18 to 89 years of age who had at least 1 year of cochlear implant use and who were recruited through a consortium of 20 cochlear implant centers in the United States. Using an online format, questionnaires were sent to the first 500 participants who contacted the research team. Of these participants, 371 (74.2%) completed the questionnaire. Demographic, hearing-related, and cochlear implant-related data were obtained along with responses to each of the 81 items in the CIQOL item bank. Multivariable linear regression was used to examine demographic, hearing-related, and cochlear implant-related factors associated with scores in each of the 6 CIQOL domains (communication, emotional, entertainment, environment, listening effort, and social). Main Outcomes and Measures Association among demographic, hearing-related, and cochlear implant-related factors and CIQOL scores for each of 6 domains. Results Of the 371 participants who completed the questionnaire, 222 (59.8%) were women, and the mean (SD) age was 59.5 (14.9) years. The CIQOL scores were normally distributed across the 6 domains. Being employed, having higher household income, longer duration of hearing loss prior to cochlear implantation, and having bilateral rather than unilateral cochlear implantation were associated with higher CIQOL scores in 1 or more domains, but the effect size varied widely (β, 0.1-6.9). Better sentence recognition ability (using AzBio to measure speech recognition) was associated with only a small positive effect size for the communication (β, 0.0 [95% CI, 0.0-0.1]), entertainment (β, 0.0 [95% CI, 0.0-0.1]), and environmental (β, 0.0 [95% CI, 0.0-0.0]) domains. Increased age was associated with lower CIQOL in the entertainment domain (β, -0.3 [95% CI, -1.5 to -0.4]). The demographic, hearing-related, and cochlear implant-related factors included in the multivariable regression models accounted for only a small percentage of the variance in CIQOL domain scores (R2, 0.08-0.17). Conclusions and Relevance Several factors were found to predict higher or lower CIQOL scores in specific domains, with speech-recognition ability having only a minimal association. Despite evaluating a large number of demographic, hearing-related, and cochlear implant-related factors, the multivariable models accounted for only a small amount of CIQOL variance. This suggests that patient or other characteristics that contribute to cochlear implant-related quality of life remain largely unknown.
Collapse
Affiliation(s)
- Theodore R McRackan
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston
| | - Brittany N Hand
- School of Health and Rehabilitation Sciences, The Ohio State University, Columbus
| | - Craig A Velozo
- Division of Occupational Therapy, Medical University of South Carolina, Charleston
| | - Judy R Dubno
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston
| |
Collapse
|
38
|
Abstract
OBJECTIVE The objectives of this study were to assess the effectiveness of various measures of speech understanding in distinguishing performance differences between adult bimodal and bilateral cochlear implant (CI) recipients and to provide a preliminary evidence-based tool guiding clinical decisions regarding bilateral CI candidacy. DESIGN This study used a multiple-baseline, cross-sectional design investigating speech recognition performance for 85 experienced adult CI recipients (49 bimodal, 36 bilateral). Speech recognition was assessed in a standard clinical test environment with a single loudspeaker using the minimum speech test battery for adult CI recipients as well as with an R-SPACE 8-loudspeaker, sound-simulation system. All participants were tested in three listening conditions for each measure including each ear alone as well as in the bilateral/bimodal condition. In addition, we asked each bimodal listener to provide a yes/no answer to the question, "Do you think you need a second CI?" RESULTS This study yielded three primary findings: (1) there were no significant differences between bimodal and bilateral CI performance or binaural summation on clinical measures of speech recognition, (2) an adaptive speech recognition task in the R-SPACE system revealed significant differences in performance and binaural summation between bimodal and bilateral CI users, with bilateral CI users achieving significantly better performance and greater summation, and (3) the patient's answer to the question, "Do you think you need a second CI?" held high sensitivity (100% hit rate) for identifying likely bilateral CI candidates and moderately high specificity (77% correct rejection rate) for correctly identifying listeners best suited with a bimodal hearing configuration. CONCLUSIONS Clinics cannot rely on current clinical measures of speech understanding, with a single loudspeaker, to determine bilateral CI candidacy for adult bimodal listeners nor to accurately document bilateral benefit relative to a previous bimodal hearing configuration. Speech recognition in a complex listening environment, such as R-SPACE, is a sensitive and appropriate measure for determining bilateral CI candidacy and also likely for documenting bilateral benefit relative to a previous bimodal configuration. In the absence of an available R-SPACE system, asking the patient whether or not s/he thinks s/he needs a second CI is a highly sensitive measure, which may prove clinically useful.
Collapse
|
39
|
The Effect of Hearing Aid Bandwidth and Configuration of Hearing Loss on Bimodal Speech Recognition in Cochlear Implant Users. Ear Hear 2019; 40:621-635. [PMID: 30067559 DOI: 10.1097/aud.0000000000000638] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES (1) To determine the effect of hearing aid (HA) bandwidth on bimodal speech perception in a group of unilateral cochlear implant (CI) patients with diverse degrees and configurations of hearing loss in the nonimplanted ear, (2) to determine whether there are demographic and audiometric characteristics that would help to determine the appropriate HA bandwidth for a bimodal patient. DESIGN Participants were 33 experienced bimodal device users with postlingual hearing loss. Twenty three of them had better speech perception with the CI than the HA (CI>HA group) and 10 had better speech perception with the HA than the CI (HA>CI group). Word recognition in sentences (AzBio sentences at +10 dB signal to noise ratio presented at 0° azimuth) and in isolation [CNC (consonant-nucleus-consonant) words] was measured in unimodal conditions [CI alone or HAWB, which indicates HA alone in the wideband (WB) condition] and in bimodal conditions (BMWB, BM2k, BM1k, and BM500) as the bandwidth of an actual HA was reduced from WB to 2 kHz, 1 kHz, and 500 Hz. Linear mixed-effect modeling was used to quantify the relationship between speech recognition and listening condition and to assess how audiometric or demographic covariates might influence this relationship in each group. RESULTS For the CI>HA group, AzBio scores were significantly higher (on average) in all bimodal conditions than in the best unimodal condition (CI alone) and were highest at the BMWB condition. For CNC scores, on the other hand, there was no significant improvement over the CI-alone condition in any of the bimodal conditions. The opposite pattern was observed in the HA>CI group. CNC word scores were significantly higher in the BM2k and BMWB conditions than in the best unimodal condition (HAWB), but none of the bimodal conditions were significantly better than the best unimodal condition for AzBio sentences (and some of the restricted bandwidth conditions were actually worse). Demographic covariates did not interact significantly with bimodal outcomes, but some of the audiometric variables did. For CI>HA participants with a flatter audiometric configuration and better mid-frequency hearing, bimodal AzBio scores were significantly higher than the CI-alone score with the WB setting (BMWB) but not with other bandwidths. In contrast, CI>HA participants with more steeply sloping hearing loss and poorer mid-frequency thresholds (≥82.5 dB) had significantly higher bimodal AzBio scores in all bimodal conditions, and the BMWB did not differ significantly from the restricted bandwidth conditions. HA>CI participants with mild low-frequency hearing loss showed the highest levels of bimodal improvement over the best unimodal condition on CNC words. They were also less affected by HA bandwidth reduction compared with HA>CI participants with poorer low-frequency thresholds. CONCLUSIONS The pattern of bimodal performance as a function of the HA bandwidth was found to be consistent with the degree and configuration of hearing loss for both patients with CI>HA performance and for those with HA>CI performance. Our results support fitting the HA for all bimodal patients with the widest bandwidth consistent with effective audibility.
Collapse
|
40
|
Digeser FM, Engler M, Hoppe U. Comparison of bimodal benefit for the use of DSL v5.0 and NAL-NL2 in cochlear implant listeners. Int J Audiol 2019; 59:383-391. [PMID: 31809219 DOI: 10.1080/14992027.2019.1697902] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Objective: For a group of bimodal subjects with moderate to severe hearing loss contralateral to the cochlear implant (CI), the bimodal benefit of the hearing aid (HA) gain prescriptions DSL v5.0, NAL-NL2 and the recipients' own gain setting were assessed.Design: Speech perception in quiet and in noise as well as self-reported ratings of benefit were determined for all three gain-settings. Speech tests were performed in the bimodal, the HA alone and the CI alone condition. The bimodal benefit was assessed for each prescription as the difference score of the bimodal condition and the better ear.Study Sample: Twenty adults with post-lingual hearing loss.Results: Speech perception with DSL v5.0 was significantly higher compared to NAL-NL2 and the own prescription in both quiet and noise. The median bimodal benefit was highest for DSL v5.0 with an average of 15 percentage points for both words in quiet and sentences in noise.Conclusions: DSL v5.0 and NAL-NL2 are both suitable for HA fitting in bimodal users. For subjects with moderate to severe hearing loss and HA experience contralateral to the implanted side, DSL v5.0 may provide better speech perception and bimodal benefit.
Collapse
Affiliation(s)
- Frank M Digeser
- Audiologie, HNO Klinik, Universitätsklinikum Erlangen, Erlangen, Germany
| | - Max Engler
- Audiologie, HNO Klinik, Universitätsklinikum Erlangen, Erlangen, Germany
| | - Ulrich Hoppe
- Audiologie, HNO Klinik, Universitätsklinikum Erlangen, Erlangen, Germany
| |
Collapse
|
41
|
Sharma S, Mens LHM, Snik AFM, van Opstal AJ, van Wanrooij MM. An Individual With Hearing Preservation and Bimodal Hearing Using a Cochlear Implant and Hearing Aids Has Perturbed Sound Localization but Preserved Speech Perception. Front Neurol 2019; 10:637. [PMID: 31293495 PMCID: PMC6598447 DOI: 10.3389/fneur.2019.00637] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Accepted: 05/30/2019] [Indexed: 11/13/2022] Open
Abstract
This study describes sound localization and speech-recognition-in-noise abilities of a cochlear-implant user with electro-acoustic stimulation (EAS) in one ear, and a hearing aid in the contralateral ear. This listener had low-frequency, up to 250 Hz, residual hearing within the normal range in both ears. The objective was to determine how hearing devices affect spatial hearing for an individual with substantial unaided low-frequency residual hearing. Sound-localization performance was assessed for three sounds with different bandpass characteristics: low center frequency (100-400 Hz), mid center frequency (500-1,500 Hz) and high frequency broad-band (500-20,000 Hz) noise. Speech recognition was assessed with the Dutch Matrix sentence test presented in noise. Tests were performed while the listener used several on-off combinations of the devices. The listener localized low-center frequency sounds well in all hearing conditions, but mid-center frequency and high frequency broadband sounds were localized well almost exclusively in the completely unaided condition (mid-center frequency sounds were also localized well with the EAS device alone). Speech recognition was best in the fully aided condition with speech presented in the front and noise presented at either side. Furthermore, there was no significant improvement in speech recognition with all devices on, compared to when the listener used her cochlear implant only. Hearing aids and cochlear implant impair high frequency spatial hearing due to improper weighing of interaural time and level difference cues. The results reinforce the notion that hearing symmetry is important for sound localization. The symmetry is perturbed by the hearing devices for higher frequencies. Speech recognition depends mainly on hearing through the cochlear implant and is not significantly improved with the added information from hearing aids. A contralateral hearing aid provides benefit when the noise is spatially separated from the speech. However, this benefit is explained by the head shadow in that ear, rather than by an ability to spatially segregate noise from speech, as sound localization was perturbed with all devices in use.
Collapse
Affiliation(s)
- Snandan Sharma
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, Netherlands
| | - Lucas H M Mens
- Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, Netherlands
| | - Ad F M Snik
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, Netherlands
| | - A John van Opstal
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, Netherlands
| | - Marc M van Wanrooij
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, Radboud University, Nijmegen, Netherlands
| |
Collapse
|
42
|
Rader T, Bohnert A, Matthias C, Koutsimpelas D, Kainz MA, Strieth S. Hearing preservation in children with electric-acoustic stimulation after cochlear implantation : Outcome after electrode insertion with minimal insertion trauma. HNO 2019; 66:56-62. [PMID: 30132125 PMCID: PMC7062660 DOI: 10.1007/s00106-018-0532-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Background Cochlear implantation in patients with functional residual low-frequency hearing is performed according to an established hearing-preserving surgical technique in order to cause minimal trauma of inner ear structures. Due to the increasing number of cochlear implants in children, the preservation of residual hearing is becoming increasingly important in this patient collective. Objectives Short- and mid-term hearing preservation outcome in pediatric patients is investigated. Materials and methods A group of 9 children (12 ears) between 5 and 12 years of age were examined after hearing-assisted cochlear implantation with respect to the pure tone audiometric thresholds. Retrospectively, short-term hearing preservation (up to 3 months after surgery) was examined. In a subgroup of 5 children, mid-term hearing preservation (7.5 to 16 months after surgery) was also analyzed. The mean values of hearing preserved (HL%) and hearing loss (HL) due to electrode insertion were calculated as measured values. Results In the whole group, the mean values of the preoperative PTAlow were 29.8 dB and the short-term postoperative PTAlow 42.6 dB. The mean value of the HL% was 73.6%, corresponding to an HL of 9.4 dB. In the subgroup, the mean PTAlow postoperatively was 46.0 dB in the mid-term and the HL% at 80.7% with a HL of 6.6 dB. Conclusions The results in children are consistent with the results in adults. Electric-acoustic stimulation (EAS) should be used in the treatment of children with existing low-frequency residual hearing, as good residual hearing preservation can also be achieved in children after implantation.
Collapse
Affiliation(s)
- T Rader
- Audiological Acoustics Division, Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany.
| | - A Bohnert
- Audiological Acoustics Division, Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - C Matthias
- Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - D Koutsimpelas
- Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - M-A Kainz
- Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - S Strieth
- Department of Otolaryngology, Head and Neck Surgery, University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
43
|
Effects of Additional Low-Pass-Filtered Speech on Listening Effort for Noise-Band-Vocoded Speech in Quiet and in Noise. Ear Hear 2019; 40:3-17. [PMID: 29757801 PMCID: PMC6319586 DOI: 10.1097/aud.0000000000000587] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Objectives: Residual acoustic hearing in electric–acoustic stimulation (EAS) can benefit cochlear implant (CI) users in increased sound quality, speech intelligibility, and improved tolerance to noise. The goal of this study was to investigate whether the low-pass–filtered acoustic speech in simulated EAS can provide the additional benefit of reducing listening effort for the spectrotemporally degraded signal of noise-band–vocoded speech. Design: Listening effort was investigated using a dual-task paradigm as a behavioral measure, and the NASA Task Load indeX as a subjective self-report measure. The primary task of the dual-task paradigm was identification of sentences presented in three experiments at three fixed intelligibility levels: at near-ceiling, 50%, and 79% intelligibility, achieved by manipulating the presence and level of speech-shaped noise in the background. Listening effort for the primary intelligibility task was reflected in the performance on the secondary, visual response time task. Experimental speech processing conditions included monaural or binaural vocoder, with added low-pass–filtered speech (to simulate EAS) or without (to simulate CI). Results: In Experiment 1, in quiet with intelligibility near-ceiling, additional low-pass–filtered speech reduced listening effort compared with binaural vocoder, in line with our expectations, although not compared with monaural vocoder. In Experiments 2 and 3, for speech in noise, added low-pass–filtered speech allowed the desired intelligibility levels to be reached at less favorable speech-to-noise ratios, as expected. It is interesting that this came without the cost of increased listening effort usually associated with poor speech-to-noise ratios; at 50% intelligibility, even a reduction in listening effort on top of the increased tolerance to noise was observed. The NASA Task Load indeX did not capture these differences. Conclusions: The dual-task results provide partial evidence for a potential decrease in listening effort as a result of adding low-frequency acoustic speech to noise-band–vocoded speech. Whether these findings translate to CI users with residual acoustic hearing will need to be addressed in future research because the quality and frequency range of low-frequency acoustic sound available to listeners with hearing loss may differ from our idealized simulations, and additional factors, such as advanced age and varying etiology, may also play a role.
Collapse
|
44
|
Holder JT, Reynolds SM, Sunderhaus LW, Gifford RH. Current Profile of Adults Presenting for Preoperative Cochlear Implant Evaluation. Trends Hear 2019; 22:2331216518755288. [PMID: 29441835 PMCID: PMC6027468 DOI: 10.1177/2331216518755288] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Considerable advancements in cochlear implant technology (e.g., electric acoustic stimulation) and assessment materials have yielded expanded criteria. Despite this, it is unclear whether individuals with better audiometric thresholds and speech understanding are being referred for cochlear implant workup and pursuing cochlear implantation. The purpose of this study was to characterize the mean auditory and demographic profile of adults presenting for preoperative cochlear implant workup. Data were collected prospectively for all adult preoperative workups at Vanderbilt from 2013 to 2015. Subjects included 287 adults (253 postlingually deafened) with a mean age of 62.3 years. Each individual was assessed using the minimum speech test battery, spectral modulation detection, subjective questionnaires, and cognitive screening. Mean consonant-nucleus-consonant word scores, AzBio sentence scores, and pure-tone averages for postlingually deafened adults were 10%, 13%, and 89 dB HL, respectively, for the ear to be implanted. Seventy-three individuals (25.4%) met labeled indications for Hybrid-L and 207 individuals (72.1%) had aidable hearing in the better hearing ear to be used in a bimodal hearing configuration. These results suggest that mean speech understanding evaluated at cochlear implant workup remains very low despite recent advancements. Greater awareness and insurance accessibility may be needed to make cochlear implant technology available to those who qualify for electric acoustic stimulation devices as well as individuals meeting conventional cochlear implant criteria.
Collapse
Affiliation(s)
- Jourdan T Holder
- 1 Department of Hearing and Speech Science, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Susan M Reynolds
- 1 Department of Hearing and Speech Science, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Linsey W Sunderhaus
- 1 Department of Hearing and Speech Science, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, TN, USA
| | - René H Gifford
- 1 Department of Hearing and Speech Science, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, TN, USA.,2 Advanced Bionics, Valencia, CA, USA.,3 Cochlear Americas, Englewood, CO, USA.,4 Frequency Therapeutics, Woburn, MA, USA
| |
Collapse
|
45
|
Weissgerber T, Stöver T, Baumann U. Speech perception in noise: Impact of directional microphones in users of combined electric-acoustic stimulation. PLoS One 2019; 14:e0213251. [PMID: 30840668 PMCID: PMC6402691 DOI: 10.1371/journal.pone.0213251] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 02/18/2019] [Indexed: 12/02/2022] Open
Abstract
Objectives Combined electric-acoustic stimulation (EAS) is a well-accepted therapeutic treatment for cochlear implant (CI) users with residual hearing in the low frequencies but severe to profound hearing loss in the high frequencies. The recently introduced SONNETeas audio processor offers different microphone directionality (MD) settings and wind noise reduction (WNR) as front-end processing. The aim of this study was to compare speech perception in quiet and noise between two EAS audio processors DUET 2 and SONNETeas, to assess the impact of MD and WNR on speech perception in EAS users in the absence of wind. Furthermore, subjective rating of hearing performance was registered. Method Speech perception and subjective rating with SONNETeas or DUET 2 audio processor were assessed in 10 experienced EAS users. Speech perception was measured in quiet and in a diffuse noise setup (MSNF). The SONNETeas processor was tested with three MD settings omnidirectional/natural/adaptive and with different intensities of WNR. Subjective rating of auditory benefit and sound quality was rated using two questionnaires. Results There was no significant difference between DUET 2 and SONNETeas processor using the omnidirectional microphone in quiet and in noise. There was a significant improvement in SRT with MD settings natural (2.2 dB) and adaptive (3.6 dB). No detrimental effect of the WNR algorithm on speech perception was found in the absence of wind. Sound quality was rated as “moderate” for both audio processors. Conclusions The different MD settings of the SONNETeas can provide EAS users with better speech perception compared to an omnidirectional microphone. Concerning speech perception in quiet and quality of life, the performance of the DUET 2 and SONNETeas audio processors was comparable.
Collapse
Affiliation(s)
- Tobias Weissgerber
- Audiological Acoustics, ENT Department, University Hospital Frankfurt, Frankfurt am Main, Germany
- * E-mail:
| | - Timo Stöver
- ENT Department, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Uwe Baumann
- Audiological Acoustics, ENT Department, University Hospital Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
46
|
Warren CD, Nel E, Boyd PJ. Controlled comparative clinical trial of hearing benefit outcomes for users of the Cochlear™ Nucleus ® 7 Sound Processor with mobile connectivity. Cochlear Implants Int 2019; 20:116-126. [PMID: 30714500 DOI: 10.1080/14670100.2019.1572984] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To assess subjective benefits and objective speech recognition performance following a take-home trial with the new Cochlear™ Nucleus® 7 Sound Processor (SP), in experienced users of compatible cochlear implants from Cochlear Limited. METHODS A total of 37 adult participants were fitted with the Nucleus 7 SP and used the device for up to one year. Baseline speech recognition was assessed at the initial fitting session, using each participant's own SP, and Client Oriented Scale of Improvement (COSI) goals were identified. Speech recognition was measured after 3 months of device use and outcomes of the COSI and a non-validated Processor Comparison Questionnaire (PCQ) were collected. After 11 months, a subset of subjects were tested on speech recognition delivered via direct wireless streaming from an Apple® smartphone to the SP and compatible hearing aid on the opposite side (if worn). RESULTS The COSI and PCQ instruments both indicated significant improvement in perceived subjective benefits in comparison to the participants' previous SPs. Direct streaming via an Apple mobile phone showed improvements when compared with the acoustic alone condition. Standard speech recognition in quiet and noise was equivalent to that obtained using a previous generation SP which uses the same basic processing as the Nucleus 7 Sound Processor. CONCLUSIONS The incremental refinements provided by the Nucleus 7 Sound Processor provide real-world benefits in key areas such as upgraded wireless connectivity. The COSI proved to be an effective tool for individualized assessment of specific benefits that may not be addressed by more standardized instruments.
Collapse
Affiliation(s)
| | - Esti Nel
- a Cochlear Ltd , Sydney , Australia
| | | |
Collapse
|
47
|
Yoon YS, Shin YR, Kim JM, Coltisor A, Chun YM. Optimizing maps for electric acoustic stimulation users. Cochlear Implants Int 2019; 20:106-115. [DOI: 10.1080/14670100.2019.1572939] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Yang-Soo Yoon
- Department of Communication Sciences and Disorders, Baylor University, Waco, TX, USA
| | | | | | | | | |
Collapse
|
48
|
Abstract
OBJECTIVES Cochlear implant (CI) users suffer from a range of speech impairments, such as stuttering and vocal control of pitch and intensity. Though little research has focused on the role of auditory feedback in the speech of CI users, these speech impairments could be due in part to limited access to low-frequency cues inherent in CI-mediated listening. Phantom electrode stimulation (PES) represents a novel application of current steering that extends access to low frequencies for CI recipients. It is important to note that PES transmits frequencies below 300 Hz, whereas Baseline does not. The objective of this study was to explore the effects of PES on multiple frequency-related characteristics of voice production. DESIGN Eight postlingually deafened, adult Advanced Bionics CI users underwent a series of vocal production tests including Tone Repetition, Vowel Sound Production, Passage Reading, and Picture Description. Participants completed all of these tests twice: once with PES and once using their program used for everyday listening (Baseline). An additional test, Automatic Modulation, was included to measure acute effects of PES and was completed only once. This test involved switching between PES and Baseline at specific time intervals in real time as participants read a series of short sentences. Finally, a subjective Vocal Effort measurement was also included. RESULTS In Tone Repetition, the fundamental frequencies (F0) of tones produced using PES and the size of musical intervals produced using PES were significantly more accurate (closer to the target) compared with Baseline in specific gender, target tone range, and target tone type testing conditions. In the Vowel Sound Production task, vowel formant profiles produced using PES were closer to that of the general population compared with those produced using Baseline. The Passage Reading and Picture Description task results suggest that PES reduces measures of pitch variability (F0 standard deviation and range) in natural speech production. No significant results were found in comparisons of PES and Baseline in the Automatic Modulation task nor in the Vocal Effort task. CONCLUSIONS The findings of this study suggest that usage of PES increases accuracy of pitch matching in repeated sung tones and frequency intervals, possibly due to more accurate F0 representation. The results also suggest that PES partially normalizes the vowel formant profiles of select vowel sounds. PES seems to decrease pitch variability of natural speech and appears to have limited acute effects on natural speech production, though this finding may be due in part to paradigm limitations. On average, subjective ratings of vocal effort were unaffected by the usage of PES versus Baseline.
Collapse
|
49
|
Zaleski-King A, Goupell MJ, Barac-Cikoja D, Bakke M. Bimodal Cochlear Implant Listeners' Ability to Perceive Minimal Audible Angle Differences. J Am Acad Audiol 2018; 30:659-671. [PMID: 30417825 DOI: 10.3766/jaaa.17012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Bilateral inputs should ideally improve sound localization and speech understanding in noise. However, for many bimodal listeners [i.e., individuals using a cochlear implant (CI) with a contralateral hearing aid (HA)], such bilateral benefits are at best, inconsistent. The degree to which clinically available HA and CI devices can function together to preserve interaural time and level differences (ITDs and ILDs, respectively) enough to support the localization of sound sources is a question with important ramifications for speech understanding in complex acoustic environments. PURPOSE To determine if bimodal listeners are sensitive to changes in spatial location in a minimum audible angle (MAA) task. RESEARCH DESIGN Repeated-measures design. STUDY SAMPLE Seven adult bimodal CI users (28-62 years). All listeners reported regular use of digital HA technology in the nonimplanted ear. DATA COLLECTION AND ANALYSIS Seven bimodal listeners were asked to balance the loudness of prerecorded single syllable utterances. The loudness-balanced stimuli were then presented via direct audio inputs of the two devices with an ITD applied. The task of the listener was to determine the perceived difference in processing delay (the interdevice delay [IDD]) between the CI and HA devices. Finally, virtual free-field MAA performance was measured for different spatial locations both with and without inclusion of the IDD correction, which was added with the intent to perceptually synchronize the devices. RESULTS During the loudness-balancing task, all listeners required increased acoustic input to the HA relative to the CI most comfortable level to achieve equal interaural loudness. During the ITD task, three listeners could perceive changes in intracranial position by distinguishing sounds coming from the left or from the right hemifield; when the CI was delayed by 0.73, 0.67, or 1.7 msec, the signal lateralized from one side to the other. When MAA localization performance was assessed, only three of the seven listeners consistently achieved above-chance performance, even when an IDD correction was included. It is not clear whether the listeners who were able to consistently complete the MAA task did so via binaural comparison or by extracting monaural loudness cues. Four listeners could not perform the MAA task, even though they could have used a monaural loudness cue strategy. CONCLUSIONS These data suggest that sound localization is extremely difficult for most bimodal listeners. This difficulty does not seem to be caused by large loudness imbalances and IDDs. Sound localization is best when performed via a binaural comparison, where frequency-matched inputs convey ITD and ILD information. Although low-frequency acoustic amplification with a HA when combined with a CI may produce an overlapping region of frequency-matched inputs and thus provide an opportunity for binaural comparisons for some bimodal listeners, our study showed that this may not be beneficial or useful for spatial location discrimination tasks. The inability of our listeners to use monaural-level cues to perform the MAA task highlights the difficulty of using a HA and CI together to glean information on the direction of a sound source.
Collapse
Affiliation(s)
- Ashley Zaleski-King
- Department of Speech and Hearing Sciences, Gallaudet University, Washington, DC
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland College Park, College Park, MD
| | | | - Matthew Bakke
- Department of Speech and Hearing Sciences, Gallaudet University, Washington, DC
| |
Collapse
|
50
|
Welch C, Dillon MT, Pillsbury HC. Electric and Acoustic Stimulation in Cochlear Implant Recipients with Hearing Preservation. Semin Hear 2018; 39:414-427. [PMID: 30374212 PMCID: PMC6203459 DOI: 10.1055/s-0038-1670707] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
Abstract
Hearing loss affects 30 million people in the United States, and a subset of these patients have normal low-frequency hearing and ski-sloped high-frequency hearing loss. For these patients, hearing aids alone may not provide adequate benefit. Cochlear implantation alone has been utilized to improve speech perception. The addition of high-frequency electric hearing to low-frequency acoustic hearing in these patients is beneficial. Technical improvements have allowed preservation of low-frequency hearing in cochlear implant recipients, allowing for electric and acoustic stimulation in the same ear with significant improvements in speech perception, sound localization, music appreciation, and quality of life.
Collapse
Affiliation(s)
- Christopher Welch
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Margaret T. Dillon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Harold C. Pillsbury
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| |
Collapse
|