1
|
Lynch BT, Montgomery BK, Verhofste BP, Proctor MR, Hedequist DJ. Two-Surgeon Multidisciplinary Approach to Pediatric Cervical Spinal Fusion: A Single-Institution Series and Review of the Literature. J Pediatr Orthop 2023; 43:392-399. [PMID: 36941115 DOI: 10.1097/bpo.0000000000002396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
BACKGROUND A collaborative 2-surgeon approach is becoming increasingly popular in surgery but is not widely used for pediatric cervical spine fusions. The goal of this study is to present a large single-institution experience with pediatric cervical spinal fusion using a multidisciplinary 2-surgeon team, including a neurosurgeon and an orthopedic surgeon. This team-based approach has not been previously reported in the pediatric cervical spine literature. METHODS A single-institution review of pediatric cervical spine instrumentation and fusion performed by a surgical team composed of neurosurgery and orthopedics during 2002-2020 was performed. Demographics, presenting symptoms and indications, surgical characteristics, and outcomes were recorded. Particular focus was given to describe the primary surgical responsibility of the orthopedic surgeon and the neurosurgeon. RESULTS A total of 112 patients (54% male) with an average age of 12.1 (range 2-26) years met the inclusion criteria. The most common indications for surgery were os odontoideum with instability (n=21) and trauma (n=18). Syndromes were present in 44 (39%) cases. Fifty-five (49%) patients presented with preoperative neurological deficits (26 motor, 12 sensory, and 17 combined deficits). At the time of the last clinical follow-up, 44 (80%) of these patients had stabilization or resolution of their neurological deficit. There was 1 new postoperative neural deficit (1%). The average time between surgery and successful radiologic arthrodesis was 13.2±10.6 mo. A total of 15 (13%) patients experienced complications within 90 days of surgery (2 intraoperative, 6 during admission, and 7 after discharge). CONCLUSIONS A multidisciplinary 2-surgeon approach to pediatric cervical spine instrumentation and fusion provides a safe treatment option for complex pediatric cervical cases. It is hoped that this study could provide a model for other pediatric spine groups interested in implementing a multi-specialty 2-surgeon team to perform complex pediatric cervical spine fusions. LEVEL OF EVIDENCE Level IV-case series.
Collapse
Affiliation(s)
- Benjamin T Lynch
- Department of Orthopaedic Surgery
- Department of Neurosurgery, Boston Children's Hospital
- Harvard Medical School, Boston, MA
| | | | - Bram P Verhofste
- Department of Orthopaedic Surgery
- Harvard Medical School, Boston, MA
| | - Mark R Proctor
- Department of Neurosurgery, Boston Children's Hospital
- Harvard Medical School, Boston, MA
| | | |
Collapse
|
2
|
Pediatric craniocervical fusion: predictors of surgical outcomes, risk of recurrence, and re-operation. Childs Nerv Syst 2022; 38:1531-1539. [PMID: 35511272 DOI: 10.1007/s00381-022-05541-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 04/22/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE Craniocervical junction abnormalities include a wide variety of disorders and can be classified into congenital or acquired. This study aimed to review the surgical outcome of pediatric patients who underwent craniocervical and/or atlantoaxial fusion. METHODS This is a retrospective cohort study including all pediatric patients (≤ 18 years) who underwent craniocervical and/or atlantoaxial fusion between 2009 and 2019 at quaternary medical city. RESULTS A total of 25 patients met our criteria and were included in the study. The mean age was 9 years (range: 1-17 years). There was a slight female preponderance (N = 13; 52%). Most patients (N = 16; 64%) had non-trauamatic/chronic causes of craniocervical instability. Most patients presented with neck pain and/or stiffness (N = 14; 56%). Successful fusion of the craniocervical junction was achieved in most patients (N = 21; 84%). Intraoperative complications were encountered in 12% (N = 3) of the patients. Early postoperative complications were observed in five patients (20%). Five patients (20%) experienced long-term complications. Revision was needed in two patients (8%). Older age was significantly associated with higher fusion success rates (p = 0.003). The need for revision surgery rates was significantly higher among younger age group (3.75 ± 2, p = 0.01). CONCLUSIONS The study demonstrates the surgical outcome of craniocervical and/or atlantoaxial fusion in pediatric patients. Successful fusion of the craniocervical junction was achieved in most patients. Significant association was found between older age and successful fusion, and between younger age and need for revision surgery.
Collapse
|
3
|
Shekhar H, Mancuso-Marcello M, Emelifeonwu J, Gallo P, Sokol D, Kandasamy J, Kaliaperumal C. Management of traumatic atlanto-occipital dislocation in a 10-year-old with noninvasive halo immobilization: A case report. Surg Neurol Int 2022; 13:222. [PMID: 35673640 PMCID: PMC9168337 DOI: 10.25259/sni_17_2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 05/03/2022] [Indexed: 11/27/2022] Open
Abstract
Background Traumatic atlanto-occipital dislocation is an unstable injury of the craniocervical junction. For pediatric patients, surgical arthrodesis of the occipitocervical junction is the recommended management. While having a high success rate for stabilization, the fusion comes with obvious morbidity of limitation in cervical spine flexion, extension, and rotation. An alternative is external immobilization with a conventional halo. Case Description We describe the case of a 10-year-old boy who was treated successfully for traumatic AOD with a noninvasive pinless halo. Following initial brain trauma management, we immobilized the craniocervical junction with a pinless halo after reducing the atlanto-occipital dislocation. The pinless halo was kept on at all times for the next 3 months. The craniocervical junction alignment was monitored with weekly cervical spine X-rays and CT craniocervical junction on day 15th, day 30th, and day 70th. A follow-up MRI C-spine 3 months from presentation confirmed resolution of the soft-tissue injury and the pinless halo was removed. Dynamic cervical spine X-rays revealed satisfactory alignment in both flexion and extension views. The patient has been followed up for 2 years postinjury and no issues were identified. Conclusion Noninvasive pinless halo is a potential treatment option for traumatic pediatric atlanto-occipital dislocation. This should be considered bearing in mind multiple factors including age and weight of the patient, severity of the atlanto-occipital dislocation (Grade I vs. Grade II and incomplete vs. complete), concomitant skull and scalp injury, and patient's ability to tolerate the halo. It is vital to emphasize that this necessitates close clinicoradiological monitoring.
Collapse
Affiliation(s)
- Himanshu Shekhar
- Department of Trauma and Orthopaedics, NHS Tayside, Ninewells Hospital, Dundee, United Kingdom
| | - Marco Mancuso-Marcello
- Department of Neurosurgery, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, Scotland, United Kingdom
| | - John Emelifeonwu
- Department of Neurosurgery, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, Scotland, United Kingdom
| | - Pasquale Gallo
- Department of Paediatric Neurosurgery, Birmingham Children’s Hospital, Birmingham Women’s and Children’s NHS Foundation Trust, Birmingham, United Kingdom
| | - Drahoslav Sokol
- Department of Paediatric Neurosurgery, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, United Kingdom
| | - Jothy Kandasamy
- Department of Paediatric Neurosurgery, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, United Kingdom
| | | |
Collapse
|
4
|
Reisener MJ, Arzani A, Okano I, Salzmann SN, Rentenberger C, Carrino JA, Shue J, Pumberger M, Sama AA, Cammisa FP, Girardi FP, Hughes AP. Mapping of Venous Sinus Anatomy and Occipital Bone Thickness for Safe Screw Placement in 100 Patients with 46,200 Standardized Measurements Using Computed Tomography Angiography. Spine (Phila Pa 1976) 2022; 47:E196-E202. [PMID: 34310535 DOI: 10.1097/brs.0000000000004182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Retrospective descriptive study. OBJECTIVE The aim of this study was to create topographical maps of occipital bone thickness and venous sinus (VS) presence to assess the risks of screw insertion in four commercially available occipital plates. SUMMARY OF BACKGROUND DATA Craniocervical junction instability and deformity are serious pathological conditions that require posterior fixation of the occipital bone to the cervical vertebrae. Insertion of occipital bone screws requires evaluation of both occipital bone thickness for effective internal fixation and intracranial VS presence for vascular injury prevention. Despite the surgical risks, there is a paucity of research on safe screw placement. METHODS We created a matrix of 231 standardized measurement points to analyze the occipital bone thickness and VS presence in cervical spine CT angiograms. These measurements were used to create topographical maps of occipital bone thickness and likelihood of VS presence, which we then compared to the screw hole configurations of four occipital plates. RESULTS Hundred patients were assessed. Maximum occipital bone thickness of 13.9 ± 3.3 mm was midline in the occipital bone, 45 mm from the foramen magnum, around the external occipital protuberance (EOP). Regions with thicknesses >8 mm were 2 cm lateral to the EOP at the level of the superior nuchal line and 2.5 cm inferior to the EOP. The area with the highest VS presence rate was around the EOP and the superior nuchal line. The right transverse VS was more prominent in both sexes. CONCLUSION There is a limited area of the occipital bone with thicknesses for enough screw purchase. Previous studies have shown 8 mm as the minimum screw length to reduce the risk of implant failure. In our analysis, only "T"-shaped plates had configurations with thicknesses >8 mm for each screw hole. For every screw hole in the analyzed occipital plates, there was a possibility of VS presence ranging from 8% to 33%.Level of Evidence: 5.
Collapse
Affiliation(s)
| | | | - Ichiro Okano
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Stephan N Salzmann
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Colleen Rentenberger
- Department of Orthopedic and Trauma Surgery, Medical University of Vienna, Vienna, Germany
| | - John A Carrino
- Department for Radiology, Hospital for Special Surgery, New York, NY
| | - Jennifer Shue
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Matthias Pumberger
- Department of Orthopedic and Trauma Surgery, Medical University of Berlin, Berlin, Germany
| | - Andrew A Sama
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Frank P Cammisa
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Federico P Girardi
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| | - Alexander P Hughes
- Department of Orthopedic Surgery, Spine Service, Hospital for Special Surgery, New York, NY
| |
Collapse
|
5
|
3D model-assisted instrumentation of the pediatric spine: a technical note. J Orthop Surg Res 2021; 16:586. [PMID: 34641923 PMCID: PMC8507155 DOI: 10.1186/s13018-021-02743-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 09/21/2021] [Indexed: 11/10/2022] Open
Abstract
Background Instrumentation of the pediatric spine is challenging due to anatomical constraints and the absence of specific instrumentation, which may result in iatrogenic injury and implant failure, especially in occipito-cervical constructs. Therefore, preoperative planning and in vitro testing of instrumentation may be necessary.
Methods In this paper, we present a technical note on the use of 1:1 scale patient-specific 3D printed spinal models for preoperative assessment of feasibility of spinal instrumentation with conventional spinal implants in pediatric spinal pathologies. Results The printed 3D models fully matched the intraoperative anatomy and allowed a preoperative confirmation of the feasibility of the planned instrumentation with conventional screws for adult patients. In addition, the possibility of intraoperative model assessment resulted in better intraoperative sense of spinal anatomy and easier freehand screw insertion, thereby reducing the potential for iatrogenic injury. All 3D models were printed at the surgical department at a very low cost, and the direct communication between the surgeon and the dedicated specialist allowed for multiple models or special spinal segments to be printed for more detailed consideration. Conclusions Our technical note highlights the critical steps for preoperative virtual planning and in vitro testing of spinal instrumentation on patient-specific 3D printed models at 1:1 scale. The simple and affordable method helps to better visualize pediatric spinal anatomy and confirm the suitability of preplanned conventional spinal instrumentation, thereby reducing X-ray exposure and intraoperative complications in freehand screw insertion without navigation.
Collapse
|
6
|
Miura K, Koda M, Funayama T, Takahashi H, Yamazaki M. Occipital Screw Placement Using a Navigation System for a Pathological Odontoid Fracture With a Dural Venous Sinus Variation. Cureus 2021; 13:e16610. [PMID: 34458029 PMCID: PMC8383131 DOI: 10.7759/cureus.16610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/22/2021] [Indexed: 11/12/2022] Open
Abstract
Conventional fluoroscopic guidance can provide enough information to precisely insert an occipital screw in ordinary cases. However, the occipital screw creates a potential risk of dural venous sinus injury or thrombosis. In some cases, with dural sinus variation, surgeons must especially be cautious to avoid its injury. We present a rare case of proper occipital screw placement using a navigation system for a pathological odontoid fracture with a high risk of dural venous sinus injury because of anatomical variations in the transverse and occipital sinuses. A 60-year-old man who underwent thyroidectomy at the age of 37 years for thyroid carcinoma developed acute neck pain and quadriparesis due to falling out of bed. He urgently underwent closed reduction and temporary immobilization with a halo-vest for a pathological odontoid fracture and atlantoaxial dislocation. Preoperative contrast-enhanced CT showed an absent right transverse sinus and a prominent occipital sinus as variations of the dural venous sinuses. Occipito-C7 fusion surgery was performed without intraoperative active venous bleeding or postoperative brain disorder by using a navigation system for the occipital screw placement to avoid injury to the dural sinus. Postoperative computed tomography showed bi-cortical occipital screw placement avoiding the prominent occipital sinus. The patient’s postoperative course was uneventful. In this case, although rigid occipito-cervical fixation using bi-cortical occipital screws was needed for the pathological odontoid fracture, the variation of the occipital sinus created a high risk of injury during occipital screw placement with conventional fluoroscopic guidance. There is an anatomical variation of the dural venous sinuses between individuals. Prominent occipital sinus injury may notably cause fatal complications such as massive bleeding or occlusion. Thus, we safely inserted the occipital screws using a navigation system that enabled us to avoid occipital venous sinus injury. Occipital screw placement with a navigation system can be a better option to prevent dural venous sinus injury in cases where there is variation in the dural venous sinuses, such as with a prominent occipital venous sinus.
Collapse
Affiliation(s)
- Kousei Miura
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba, JPN
| | - Masao Koda
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba, JPN
| | - Toru Funayama
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba, JPN
| | - Hiroshi Takahashi
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba, JPN
| | - Masashi Yamazaki
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba, JPN
| |
Collapse
|
7
|
Gonda DD, Huang M, Briceño V, Lam SK, Luerssen TG, Jea A. Protecting Against Postoperative Dyspnea and Dysphagia After Occipitocervical Fusion. Oper Neurosurg (Hagerstown) 2021; 18:254-260. [PMID: 31214708 DOI: 10.1093/ons/opz122] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Accepted: 02/19/2019] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Upper airway obstruction leading to dyspnea and dysphagia after occipitocervical fusion is a rare complication that has significant morbidity. OBJECTIVE To estimate the frequency of postoperative dyspnea and dysphagia in children after occipitocervical fusion and to identify variables associated with its occurrence. METHODS We retrospectively reviewed outcomes from all pediatric occipitocervical fusions at our institution between 2007 and 2014. Pre- and postoperative computed tomography (CT) scans were compared to determine differences in the clivoaxial (OC2) angles. RESULTS Sixty-seven pediatric patients underwent occipitocervical fusions. Median age was 9.6 yr (range 6 mo-18 yr). Fifty-six of 62 patients (90.3%) with at least 1 yr of follow-up had successful fusions. Eleven had pre-existing symptoms or otherwise compromised examination (eg, severe traumatic brain injury). None of 15 patients placed in extension (>2 degrees) relative to preoperative CT in Situ position developed new dyspnea or dysphagia. Nine of forty patients (23%) kept in Situ or flexed position developed new symptoms of dyspnea or dysphagia. Dysphagia in patients fused in the in Situ position was milder and resolved within a few weeks. No patient under age 5 (n = 20) developed symptoms of dyspnea or dysphagia regardless of head position. There were 3 cases of infection, 1 clinically silent vertebral artery injury, and 3 deaths at last follow-up. CONCLUSION Positioning of the child's head prior to occipitocervical fusion has considerable impact on outcomes, especially in older children. Careful measurements of the OC2 angle during surgery to ensure optimal head positioning in Situ or slightly extended position may prevent postoperative dysphagia or dyspnea.
Collapse
Affiliation(s)
- David D Gonda
- Division of Pediatric Neurosurgery, Rady Children's Hospital, Department of Neurosurgery, University of California-San Diego, San Diego, California
| | - Meng Huang
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Valentina Briceño
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Sandi K Lam
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Thomas G Luerssen
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Andrew Jea
- Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana
| |
Collapse
|
8
|
Wan M, Zong R, Xu HL, Qiao GY, Tong HY, Shang AJ, Yin YH, Yu XG. Feasibility of occipital condyle screw placement in patients with Chiari malformation type I: a computed tomography-based morphometric study. Acta Neurochir (Wien) 2021; 163:1569-1575. [PMID: 33462712 DOI: 10.1007/s00701-021-04714-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Accepted: 01/11/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND The occipital condyle (OC) screw is an alternative technique for occipitocervical fixation that is especially suitable for revision surgery in patients with Chiari malformation type I (CMI). This study aimed to investigate the feasibility and safety of this technique in patients with CMI. METHODS The CT data of 73 CMI patients and 73 healthy controls were retrospectively analyzed. The dimensions of OCs, including length, width, height, sagittal angle, and screw length, were measured in the axial, sagittal, and coronal planes using CT images. The OC available height was measured in the reconstructed oblique parasagittal plane of the trajectory. RESULTS The mean length, width, and height of OCs in CMI patients were 17.79 ± 2.31 mm, 11.20 ± 1.28 mm, and 5.87 ± 1.29 mm, respectively. All OC dimensions were significantly smaller in CMI patients compared with healthy controls. The mean screw length and sagittal angle were 19.13 ± 1.97 mm and 33.94° ± 5.43°, respectively. The mean OC available height was 6.36 ± 1.59 mm. According to criteria based on OC available height and width, 52.1% (76/146) of OCs in CMI patients could safely accommodate a 3.5-mm-diameter screw. CONCLUSIONS The OC screw is feasible in approximately half of OCs in CMI patients. Careful morphometric analyses and personalized surgical plans are necessary for the success of this operation in CMI patients.
Collapse
|
9
|
Ramos-Dávila EM, Meléndez-Flores JD, Álvarez-Pérez R, Barrera-Flores FJ, Martínez-Cobos MC, Pinales-Razo R, Quiroga-Garza A, Zarate-Garza P, Sanchez-Gomez A, Guzman-Lopez S, Elizondo-Omaña RE. Occipital condyle screw fixation viability according to age and gender anatomy: A computed tomography-based analysis. Clin Neurol Neurosurg 2020; 200:106358. [PMID: 33223342 DOI: 10.1016/j.clineuro.2020.106358] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/02/2020] [Accepted: 11/04/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To assess the Occipital condyle morphology in an all-age population of Northeastern Mexico, and determine age and gender related changes for surgical viability. METHODS A total of 175 consecutive HRCT scans were included and divided into 5 age groups. The condylar length, width, height, sagittal angle, anterior, posterior and medial intercondylar distances, and intercondylar angle of the OC were measured. RESULTS Mean condylar length, width, and height in total population were 20.58 mm, 9.42 mm, and 9.02 mm, respectively. Differences were observed in most morphometric parameters when comparing age groups. Significant intergender differences in total population were observed in most parameters, when individualizing each age group the height remained significant in all. The group with the least height measurement was aged 5-9 years, this however, could allow the OC screw (≥6.5 mm) placement. CONCLUSION Differences in most morphometric parameters of OC were observed between age groups and gender, particularly patients with 5-9 years. However, all groups presented a minimum height that allows the placement of a standard screw. A preoperative imaging study is always recommended due to the variability and complexity of the region.
Collapse
Affiliation(s)
| | | | - Ricardo Álvarez-Pérez
- Universidad Autónoma de Nuevo León, Facultad de Medicina, Hospital Universitario "Dr. José Eleuterio González", Department of Radiology and Imaging, Monterrey, Mexico.
| | | | - Maria C Martínez-Cobos
- Universidad Autónoma de Nuevo León, Facultad de Medicina, Hospital Universitario "Dr. José Eleuterio González", Department of Radiology and Imaging, Monterrey, Mexico.
| | - Ricardo Pinales-Razo
- Universidad Autónoma de Nuevo León, Facultad de Medicina, Hospital Universitario "Dr. José Eleuterio González", Department of Radiology and Imaging, Monterrey, Mexico.
| | | | - Patricio Zarate-Garza
- Human Anatomy Department, Faculty of Medicine, Universidad Autónoma, Monterrey, Mexico.
| | - Arnulfo Sanchez-Gomez
- Human Anatomy Department, Faculty of Medicine, Universidad Autónoma, Monterrey, Mexico.
| | - Santos Guzman-Lopez
- Human Anatomy Department, Faculty of Medicine, Universidad Autónoma, Monterrey, Mexico.
| | | |
Collapse
|
10
|
Occipital Condyle Screw Placement in Patients with Chiari Malformation: A Radiographic Feasibility Analysis and Cadaveric Demonstration. World Neurosurg 2020; 136:470-478. [PMID: 32204299 DOI: 10.1016/j.wneu.2020.01.150] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Accepted: 01/15/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Patients who undergo decompression surgery for Chiari malformation frequently require occipitocervical fixation. This is typically performed with occipital plates, which may cause intracranial injuries due to multiple fixation points. We undertook this study to assess the feasibility of occipital condyle (OC) screw placement as an alternative method of occipitocervical fixation in this patient population. METHODS Using a cadaveric model with navigational assistance, we performed the complete surgical procedure for occipitocervical fixation with OC screws. We then performed a morphometric analysis using measurements from computed tomography scans of 49 patients (32 adult, 17 pediatric) who had undergone occipitocervical fusion with instrumentation following decompression surgery for Chiari malformation. Bilateral morphometric data were analyzed for the adult and pediatric subgroups separately, as well as for the overall group. RESULTS The surgical procedure was successfully performed in the cadaveric model, demonstrating the feasibility of the proposed method. Ninety-eight OCs were studied in the morphometric analysis, and 80 (81.6%) met our eligibility criteria for OC screw placement. However, in 14.1% of adult OCs and 26.5% of pediatric OCs studied, placement of condylar screws would have been challenging or unsafe, according to our criteria. CONCLUSIONS Our findings suggest that OC screws provide a useful option for occipitocervical fixation in a substantial proportion of patients with Chiari malformation. However, rigorous preoperative analysis would be essential to identify appropriate candidates for this technique and exclude those in whom it should not be attempted. Additional study is warranted.
Collapse
|
11
|
Gandhi J, DiMatteo A, Joshi G, Smith NL, Khan SA. Cerebrospinal fluid leaks secondary to dural tears: a review of etiology, clinical evaluation, and management. Int J Neurosci 2020; 131:689-695. [PMID: 32242448 DOI: 10.1080/00207454.2020.1751625] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVE Damage to the dura mater often occurs in trauma cases of the head and spine, surgical procedures, lumbar punctures, and meningeal diseases. The resulting damage from dural tears, or durotomy, causes cerebrospinal fluid (CSF) to leak out into the surrounding space. The CSF leak induces intracranial hypotension, which can clinically present with a range of symptoms not limited to positional headaches which can confound accurate diagnosis. Current methods of evaluation and management of dural tears are discussed herewith, as well as the present understanding of its etiology, which may be classified as related to surgery, procedure, trauma, or connective tissue disorder. METHODS We piloted a MEDLINE® database search of literature, with emphasis on the previous five years, combining keywords such as "cerebrospinal fluid leak," "surgery," "procedure," and "trauma" to yield original research articles and case reports for building a clinical profile. RESULTS Patients with suspected dural tears should be evaluated based on criteria set by the International Headache Society, radiological findings, and a differential diagnosis to accurately identify the tear and its potential secondary complications. Afflicted patients may be treated promptly with epidural blood patches, epidural infusions, epidural fibrin glue, or surgical repair. At this time, epidural blood patches are the first line of treatment. Dural tears can be prevented to an extent by utilizing minimally invasive techniques and certain positions for lumbar puncture. Surgical, trauma, lumbar puncture, and epidural injection patients should be observed very carefully for dural tears and CSF leaks as the presenting clinical manifestations can be highly individualized and misguiding. CONCLUSION Because studies have demonstrated a high frequency of dural tears, particularly in spinal surgery patients, there is a need for prospective studies so that clinicians can develop an elaborate prevention strategy and response to avoid serious, unseen complications.
Collapse
Affiliation(s)
- Jason Gandhi
- Department of Physiology and Biophysics, Renaissance School of Medicine at Stony Brook University, Stony Brook, NY, USA.,Medical Student Research Institute, St. George's University School of Medicine, Grenada, West Indies
| | - Andrew DiMatteo
- Department of Physiology and Biophysics, Renaissance School of Medicine at Stony Brook University, Stony Brook, NY, USA
| | - Gunjan Joshi
- Department of Internal Medicine, Stony Brook Southampton Hospital, Southampton, NY, USA
| | | | - Sardar Ali Khan
- Department of Physiology and Biophysics, Renaissance School of Medicine at Stony Brook University, Stony Brook, NY, USA.,Department of Urology, Renaissance School of Medicine at Stony Brook University, Stony Brook, NY, USA
| |
Collapse
|
12
|
Verhofste BP, Glotzbecker MP, Hresko MT, Miller PE, Birch CM, Troy MJ, Karlin LI, Emans JB, Proctor MR, Hedequist DJ. Perioperative acute neurological deficits in instrumented pediatric cervical spine fusions. J Neurosurg Pediatr 2019; 24:528-538. [PMID: 31419801 DOI: 10.3171/2019.5.peds19200] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 05/22/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Pediatric cervical deformity is a complex disorder often associated with neurological deterioration requiring cervical spine fusion. However, limited literature exists on new perioperative neurological deficits in children. This study describes new perioperative neurological deficits in pediatric cervical spine instrumentation and fusion. METHODS A single-center review of pediatric cervical spine instrumentation and fusion during 2002-2018 was performed. Demographics, surgical characteristics, and neurological complications were recorded. Perioperative neurological deficits were defined as the deterioration of preexisting neurological function or the appearance of new neurological symptoms. RESULTS A total of 184 cases (160 patients, 57% male) with an average age of 12.6 ± 5.30 years (range 0.2-24.9 years) were included. Deformity (n = 39) and instability (n = 36) were the most frequent indications. Syndromes were present in 39% (n = 71), with Down syndrome (n = 20) and neurofibromatosis (n = 12) the most prevalent. Eighty-seven (48%) children presented with preoperative neurological deficits (16 sensory, 16 motor, and 55 combined deficits).A total of 178 (96.7%) cases improved or remained neurologically stable. New neurological deficits occurred in 6 (3.3%) cases: 3 hemiparesis, 1 hemiplegia, 1 quadriplegia, and 1 quadriparesis. Preoperative neurological compromise was seen in 4 (67%) of these new deficits (3 myelopathy, 1 sensory deficit) and 5 had complex syndromes. Three new deficits were anticipated with intraoperative neuromonitoring changes (p = 0.025).Three (50.0%) patients with new neurological deficits recovered within 6 months and the child with quadriparesis was regaining neurological function at the latest follow-up. Hemiplegia persisted in 1 patient, and 1 child died due a complication related to the tracheostomy. No association was found between neurological deficits and indication (p = 0.96), etiology (p = 0.46), preoperative neurological symptoms (p = 0.65), age (p = 0.56), use of halo vest (p = 0.41), estimated blood loss (p = 0.09), levels fused (p = 0.09), approach (p = 0.07), or fusion location (p = 0.07). CONCLUSIONS An improvement of the preexisting neurological deficit or stabilization of neurological function was seen in 96.7% of children after cervical spine fusion. New or progressive neurological deficits occurred in 3.3% of the patients and occurred more frequently in children with preoperative neurological symptoms. Patients with syndromic diagnoses are at higher risk to develop a deficit, probably due to the severity of deformity and the degree of cervical instability. Long-term outcomes of new neurological deficits are favorable, and 50% of patients experienced complete neurological recovery within 6 months.
Collapse
Affiliation(s)
- Bram P Verhofste
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Michael P Glotzbecker
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Michael T Hresko
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Patricia E Miller
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Craig M Birch
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Michael J Troy
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Lawrence I Karlin
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - John B Emans
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Mark R Proctor
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| | - Daniel J Hedequist
- 1Department of Orthopaedic Surgery, Boston Children's Hospital; and
- 2Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
13
|
Gumussoy I, Duman SB. Morphometric analysis of occipital condyles using alternative imaging technique. Surg Radiol Anat 2019; 42:161-169. [PMID: 31549198 DOI: 10.1007/s00276-019-02344-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 09/14/2019] [Indexed: 02/07/2023]
Abstract
PURPOSE The occipital condyles (OCs) are crucial anatomical structures in the cranial base. To our knowledge, there is no cone beam computed tomography (CBCT)-based study on the morphometric analysis of OCs. The aim of this study was to evaluate the morphometric analysis of OCs using CBCT. METHODS CBCT images of 200 OCs from 100 patients of which 39 males and 61 females in the age group of 18-67 years were included in the study population. Linear and angular measurements of OCs were performed. RESULTS The average OC width, length, height, sagittal angle, and effective height were 10.3 ± 1.3 mm, 19.6 ± 2.0 mm, 9.1 ± 1.4 mm, 7.4 ± 1.7 mm, and 35.3 ± 5.2 mm. Condylar width and sagittal angle measurements were found significantly different between the right and left sides; and were not found significant difference between the right and left sides in the measurements of condylar height, length, and effective height. Also the average intercondylar anterior distance (ICAD), intercondylar posterior distance (ICPD), distance between the basion and the anterior apex of the occipital condyle (B-AAOC), distance between the basion and posterior apex of the occipital condyle (B-PAOC), distance between the opisthion and anterior apex of occipital condyle (O-AAOC), and distance between the opisthion and posterior apex of occipital condyle (O-PAOC) were 20.9 ± 1.5 mm, 44.0 ± 2.0 mm, 12.3 ± 1.9 mm, 34.5 ± 4.2 mm, 29.8 ± 1.7 mm, and 27.0 ± 2.1 mm. There was not significant difference in the morphometric measurements among age groups. All morphometric measurements showed a significant difference depending on gender. CONCLUSIONS The morphometric evaluation of OCs may be effectively examined using CBCT. Linear and angular measurements data of OCs in the present study may be used as a reference database for future morphometric and surgical investigations.
Collapse
Affiliation(s)
- Ismail Gumussoy
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Sakarya University, Sakarya, Turkey.
| | - Suayip B Duman
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, İnonu University, Malatya, Turkey
| |
Collapse
|
14
|
Hale AT, Say I, Shah S, Dewan MC, Anderson RCE, Tomycz LD. Traumatic Occipitocervical Distraction Injuries in Children: A Systematic Review. Pediatr Neurosurg 2019; 54:75-84. [PMID: 30844793 DOI: 10.1159/000496832] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Accepted: 01/04/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND Occipitocervical distraction injuries (OCDI) in children occur on a wide spectrum of severity, and decisions about treatment suffer from a lack of rigorous guidelines and significant inter-institutional variability. While clear cases of frank atlanto-occipital dislocation (AOD) are treated with surgical stabilization, the approach for less severe cases of OCDI is not standardized. These patients require a careful assessment of both radiographic and clinical criteria, as part of a complex risk-benefit analysis, to establish whether occipitocervical fusion (OCF) is indicated. Here, we performed a systematic review of the literature that describes traumatic OCDI in children < 18 years of age. SUMMARY We performed a systematic review, according to PRISMA guidelines, of children < 18 years of age presenting with traumatic etiologies of OCDI. We searched PubMed to identify papers congruent with these criteria. Exclusion criteria included (1) reports on atraumatic causes of OCDI and (2) studies with insufficient clinical and radiographic details on individual patients. We identified 16 reports describing a total of 144 patients treated for pediatric traumatic OCDI. Based on the synthesis of these findings and the collective experience of the authors, we present the demographic, clinical, and radiographic factors that underlie OC instability, which we hope will serve as components of a grading system in the future. We considered various clinical and radiographic findings including: (1) the mechanism of injury, (2) the patient's age, (3) CT/CT angiography of head and neck findings and parameters, (4) MRI findings, and (5) neurological exam, for the purpose of determining the severity of the OCDI and offering treatment guidelines based on the summative risk of underlying OC instability. Key Messages: OCDI is a potentially devastating injury, especially in children. Although missing the diagnosis can have potentially catastrophic consequences, reverting to surgical fixation in less severe cases can subject children to unnecessary operative risk and permanently reduce their range of motion. After reviewing all the available reports of pediatric traumatic OCDI in the neurosurgical literature, we propose an outline of clinical and radiographic factors influencing underlying OC instability that could be incorporated into a grading scale to guide treatment. We hope this study stimulates discussion on the standardization of treatment for pediatric OCDI.
Collapse
Affiliation(s)
- Andrew T Hale
- Medical Scientist Training Program, Vanderbilt University School of Medicine, Nashville, Tennessee, USA,
| | - Irene Say
- Department of Neurosurgery, New Jersey Medical School and Robert Wood Johnson Medical School, Rutgers University, Nashville, Tennessee, USA
| | - Smit Shah
- Department of Neurosurgery, New Jersey Medical School and Robert Wood Johnson Medical School, Rutgers University, Nashville, Tennessee, USA
| | - Michael C Dewan
- Department of Neurosurgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Richard C E Anderson
- Division of Pediatric Neurosurgery, The Spine Hospital, Columbia University Medical Center, The Neurological Institute of New York, New York City, New York, USA
| | - Luke D Tomycz
- Department of Neurosurgery, New Jersey Medical School and Robert Wood Johnson Medical School, Rutgers University, Nashville, Tennessee, USA
| |
Collapse
|
15
|
Lee JJ, Hong JT, Kim IS, Kwon JY, Lee JB, Park JH. Significance of Multimodal Intraoperative Monitoring During Surgery in Patients with Craniovertebral Junction Pathology. World Neurosurg 2018; 118:e887-e894. [PMID: 30031195 DOI: 10.1016/j.wneu.2018.07.092] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 06/28/2018] [Accepted: 07/10/2018] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Although many studies have investigated the benefits of multimodal intraoperative monitoring (MIOM) during cervical spine surgery, the benefits of MIOM in craniovertebral junction (CVJ) surgery remain unclear. The objectives of the present study were to report our clinical experience in CVJ surgery with the use of MIOM and to identify risk factors that could affect MIOM changes during surgery of CVJ pathology. METHODS We reviewed the MIOM records of 146 patients who had undergone high cervical spinal surgery. The patients were grouped by the MIOM data recorded during surgery; the patients were included in either the MIOM or non-MIOM change group. The analyzed risk factors included demographic, myelopathy, preoperative Japanese Orthopedic Association (JOA) score, spinal cord diameter, and surgical factors. Univariate and multivariate analyses were performed to identify the risk factors for changes in MIOM data during surgery and postoperative neurological deficits. RESULTS Our results revealed that the incidence of postoperative neurological complications was 4.1% after CVJ surgery; this rate was significantly greater in the MIOM change group than in the non-MIOM change group (21.7% vs. 0.8%; P < 0.01). Multiple regression analysis revealed that preoperative myelopathy, preoperative JOA score, and congenital anomaly/tumor were independently associated with MIOM changes during surgery. CONCLUSIONS Postoperative neurological complications are not uncommon after CVJ surgery, and the incidence was significantly greater in the MIOM change group. Preoperative myelopathy, preoperative JOA score, and CVJ pathology related to congenital anomaly or tumor were independent risk factors for changes in MIOM data during surgery.
Collapse
Affiliation(s)
- Jung Jae Lee
- Department of Neurosurgery, Kangneung Asan Hospital, University of Ulsan, Ulsan, South Korea
| | - Jae Taek Hong
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea; Department of Neurosurgery, Eunpyung St. Mary's Hospital, The Catholic University of Korea, Seoul, South Korea.
| | - Il Sup Kim
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea
| | - Jae Yeol Kwon
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea
| | - Jong Beom Lee
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea
| | - Jong Hyeok Park
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea
| |
Collapse
|
16
|
Morphometric Evaluation of Occipital Condyles: Defining Optimal Trajectories and Safe Screw Lengths for Occipital Condyle-Based Occipitocervical Fixation in Indian Population. Asian Spine J 2018; 12:214-223. [PMID: 29713401 PMCID: PMC5913011 DOI: 10.4184/asj.2018.12.2.214] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 06/25/2017] [Accepted: 06/28/2017] [Indexed: 11/17/2022] Open
Abstract
Study Design Computed tomographic (CT) morphometric analysis. Purpose To assess the feasibility and safety of occipital condyle (OC)-based occipitocervical fixation (OCF) in Indians and to define anatomical zones and screw lengths for safe screw placement. Overview of Literature Limitations of occipital squama-based OCF has led to development of two novel OC-based OCF techniques. Methods Morphometric analysis was performed on the OCs of 70 Indian adults. The feasibility of placing a 3.5-mm-diameter screw into OCs was investigated. Safe trajectories and screw lengths for OC screws and C0–C1 transarticular screws without hypoglossal canal or atlantooccipital joint compromise were estimated. Results The average screw length and safe sagittal and medial angulations for OC screws were 19.9±2.3 mm, ≤6.4°±2.4° cranially, and 31.1°±3° medially, respectively. An OC screw could not be accommodated by 27% of the population. The safe sagittal angles and screw lengths for C0–C1 transarticular screw insertion (48.9°±5.7° cranial, 26.7±2.9 mm for junctional entry technique; 36.7°±4.6° cranial, 31.6±2.7 mm for caudal C1 arch entry technique, respectively) were significantly different than those in other populations. The risk of vertebral artery injury was high for the caudal C1 arch entry technique. Screw placement was uncertain in 48% of Indians due to the presence of aberrant anatomy. Conclusions There were significant differences in the metrics of OC-based OCF between Indian and other populations. Because of the smaller occipital squama dimensions in Indians, OC-based OCF techniques may have a higher application rate and could be a viable alternative/salvage option in selected cases. Preoperative CT, including three-dimensional-CT-angiography (to delineate vertebral artery course), is imperative to avoid complications resulting from aberrant bony and vascular anatomy. Our data can serve as a valuable reference guide in placing these screws safely under fluoroscopic guidance.
Collapse
|
17
|
Complications in Craniovertebral Junction Instrumentation: Hardware Removal Can Be Associated with Long-Lasting Stability. Personal Experience. ACTA NEUROCHIRURGICA. SUPPLEMENT 2017. [PMID: 28120073 DOI: 10.1007/978-3-319-39546-3_29] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
BACKGROUND The causes of craniovertebral junction (CVJ) instabilities include trauma, rheumatological diseases, tumors, infections, congenital malformations, and degenerative disease processes; these complex pathologies often require CVJ instrumentation. Hardware complications were analyzed in a personal series of 48 treated patients. In light of the analysis of very unusual radiological and clinical findings, the authors tried to better investigate the related mechanisms and to reach possible useful conclusions. METHODS In a series of 48 patients who underwent CVJ instrumentation and fusion procedures in our Institution, we describe three cases of hardware failure, due to: (1) infection; (2) radio- and chemotherapy; and (3) incorrect surgical procedure. RESULTS 1. A stable bone CVJ fusion can occur after instrumentation removal for infection, since this removal can enhance bone fusion mechanisms; 2. Radio- and chemotherapy can cause hardware failure due to interference with local bone metabolism; 3. Although old-fashioned, wiring techniques still deserve consideration, mostly in CVJ re-do surgery after screwing technique failures; nevertheless, although the procedure is simple, safe, and effective, care must be taken in the preparation of the cranial holes in order to avoid sliding complications of the U-shaped rods. CONCLUSIONS CVJ instrumentations provide reasonably good mechanical stabilization with a high rate of bony fusion. Complications, such as dislocation or rupture of the fixation system, screw loosening, dural fistula, neural or vascular damage, and wound infection, are relatively infrequent. Knowledge and prevention of these complications is fundamental to improve surgical results and outcomes.
Collapse
|
18
|
Iyer RR, Tuite GF, Meoded A, Carey CC, Rodriguez LF. A Modified Technique for Occipitocervical Fusion Using Compressed Iliac Crest Allograft Results in a High Rate of Fusion in the Pediatric Population. World Neurosurg 2017; 107:342-350. [PMID: 28790003 DOI: 10.1016/j.wneu.2017.07.172] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 07/26/2017] [Accepted: 07/29/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND In children, high rates of occipitocervical (OC) fusion have been demonstrated with the use of rigid instrumentation in combination with harvested autograft, with or without bone morphogenetic protein (BMP). Historically, the use of allograft materials demonstrated inferior OC fusion outcomes compared with autograft. However, autograft harvest harbors an increased risk of patient morbidity, and the use of BMP is costly and controversial in children. Thus, there remains a need for safer, less costly, yet efficacious techniques for OC fusion in the pediatric population. METHODS We retrospectively reviewed the charts of patients younger than 21 years of age who underwent OC fusion with structural allograft placement at our institution from 2010 to 2015. Data collected included age, sex, follow-up duration, fusion outcomes, and postoperative complications. RESULTS A total of 19 patients (8 female and 11 male) underwent OC fusion with our surgical technique. Mean age was 8.5 ± 4.3 years. Radiographic follow up data were available for 18 of 19 patients. One patient was lost to clinical follow up but had radiographic confirmation of fusion. Thus, 18 of 18 (100%) of patients with radiographic follow-up achieved successful arthrodesis as determined by computed tomography. Median duration to documented fusion was 4.5 months. Clinical follow-up was available for 17 of 19 patients and was on average 18.8 ± 13.5 months. One patient required reoperation for graft fracture 8 months after radiographic confirmation of successful fusion. There were no vertebral artery injuries or other postoperative complications. CONCLUSIONS We demonstrate a modified technique for OC fusion in children with unique structural allograft shaping and affixation, leading to excellent fusion outcomes at follow up. This technique obviates the need for autograft harvest or BMP, and may decrease postoperative morbidity.
Collapse
Affiliation(s)
- Rajiv R Iyer
- Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA
| | - Gerald F Tuite
- Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA; Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida, USA
| | - Avner Meoded
- Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA
| | - Carolyn C Carey
- Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA; Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida, USA
| | - Luis F Rodriguez
- Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA; Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida, USA.
| |
Collapse
|
19
|
A New Method of Measuring the Occipitocervical Angle That Could be Applied as an Intraoperative Indicator During Occipitocervical Fusion. Clin Spine Surg 2017; 30:E981-E987. [PMID: 27906740 DOI: 10.1097/bsd.0000000000000478] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
STUDY DESIGN A method for measuring occipitocervical angle. OBJECTIVE To develop a new method of measurement for assessing the occipitocervical angle using intraoperative fluoroscopic imaging, and to examine its reliability. SUMMARY OF BACKGROUND DATA To avoid postoperative complications following occipitocervical fusion, it is vital to obtain a suitable fusion angle between the occipital bone and the upper cervical spine. MATERIALS AND METHODS The subjects were 30 cases with occipito-atlanto-axial lesions and 30 healthy volunteers. Lateral plain radiographs of the cervical spine in neutral position were used to draw the McGregor line, the line between the external occipital protuberance and the most caudal point on the midline occipital curve (Oc line), the tangential line of the inferior endplate of the C2 vertebra (C2 line), and the posterior longitudinal line of the C2 vertebra (Ax line). The angles formed by these 4 lines and the horizontal line were measured. The O-C2 angle and the Oc-Ax angle, the new indicator, were measured by 3 doctors and reliability was evaluated. RESULTS In the disease group, mean intraobserver variances of the McGregor, Oc, C2, Ax, O-C2, and Oc-Ax angles were 0.7, 1.3, 1.5, 1.2, 1.6, and 1.9 degrees. Mean intraobserver intraclass correlation coefficients were 0.997, 0.994, 0.994, 0.997, 0.989, and 0.988, showing high intraobserver reliability for all angles. Mean interobserver intraclass correlation coefficients were 0.998, 0.996, 0.994, 0.997, 0.988, and 0.990, showing high interobserver reliability for all angles. The same reliability was obtained in the healthy group. CONCLUSIONS The Oc-Ax angle is as reliable an indicator as the conventional O-C2 angle, and could be used as a new intraoperative indicator for occipitocervical fusion. It may be particularly useful in cases where it is difficult to identify the McGregor line and/or the inferior endplate of the C2 vertebra. LEVEL OF EVIDENCE Level 3-diagnostic study.
Collapse
|
20
|
Hale AT, Dewan MC, Patel B, Geck MJ, Tomycz LD. Instrumented fusion in a 12-month-old with atlanto-occipital dislocation: case report and literature review of infant occipitocervical fusion. Childs Nerv Syst 2017; 33:1253-1260. [PMID: 28685261 DOI: 10.1007/s00381-017-3497-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 06/16/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND The treatment of atlantoaxial dislocation in very young children is challenging and lacks a consensus management strategy. DISCUSSION We review the literature on infantile occipitocervical (OC) fusion is appraised and technical considerations are organized for ease of reference. Surgical decisions such as graft type and instrumentation details are summarized, along with the use of bone morphogenic protein and post-operative orthoses. ILLUSTRATIVE CASE We present the case of a 12-month-old who underwent instrumented occipitocervical (OC) fusion in the setting of traumatic atlanto-occipital dislocation (AOD). CONCLUSION Occipitocervical (OC) arthrodesis is obtainable in very young infants and children. Surgical approaches are variable and use a combination of autologous grafting and creative screw and/or wire constructs. The heterogeneity of pathologic etiology leading to OC fusion makes it difficult to make definitive recommendations for surgical management.
Collapse
Affiliation(s)
- Andrew T Hale
- Department of Neurosurgery, Vanderbilt University School of Medicine, T4224 Medical Center North, Nashville, TN, 37232, USA.,Division of Pediatric Neurosurgery, Monroe Carell Jr. Children's Hospital, Nashville, TN, USA
| | - Michael C Dewan
- Department of Neurosurgery, Vanderbilt University School of Medicine, T4224 Medical Center North, Nashville, TN, 37232, USA. .,Division of Pediatric Neurosurgery, Monroe Carell Jr. Children's Hospital, Nashville, TN, USA.
| | - Bhairav Patel
- Department of Radiology, Dell Children's Hospital, Austin, TX, USA
| | - Matthew J Geck
- Division of Orthopedic Surgery, Dell Children's Hospital, Austin, TX, USA
| | - Luke D Tomycz
- Division of Pediatric Neurosurgery, Dell Children's Hospital, Austin, TX, USA
| |
Collapse
|
21
|
Roth AA, Tang PC, Ye MJ, Mohammad KS, Nelson RF. Improved autologous cortical bone harvest and viability with 2Flute otologic burs. Laryngoscope 2017; 128:E40-E46. [PMID: 28699273 DOI: 10.1002/lary.26779] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 05/31/2017] [Accepted: 06/06/2017] [Indexed: 11/11/2022]
Abstract
OBJECTIVES To determine if 2Flute (Stryker Corporation, Kalamazoo, MI) otologic burs improve the size, cellular content, and bone healing of autologous cortical bone grafts harvested during canal wall reconstruction (CWR) tympanomastoidectomy with mastoid obliteration. STUDY DESIGN Institutional review board-approved prospective cohort study. METHODS Human autologous cortical bone chips were harvested using various burs (4 and 6 mm diameter; multiflute, and 2Flute [Stryker Corporation]) from patients undergoing CWR tympanomastoidectomy for the treatment of chronic otitis media with cholesteatoma. Bone chip size, cell counts, cellular gene expression, and new bone formation were quantified. RESULTS Bone chips were significantly larger when harvested with 2Flute (Stryker Corporation) bur compared to multiflute burs at both 6 mm diameter (113 ± 14 μm2 vs. 66 ± 8 μm2 ; P < 0.05) and 4 mm diameter (70 ± 8 μm2 vs. 50 ± 3 μm2 ; P < 0.05). After 2 weeks in culture, cell numbers were significantly higher when harvested with 2Flute (Stryker Corporation) bur compared to multiflute burs at both 6 mm diameter (48.7 ± 3 vs. 31.8 ± 3 cells/μg bone; P < 0.05) and 4 mm diameter (27.6 ± 1.2 vs. 8.8 ± 1.2 cells/μg bone; P < 0.05). Bone-derived cells express osteoblast markers (alkaline phosphatase, osteocalcin). Cultured cells are able to form new bone in culture, and bone formation is facilitated by the presence of bone chips. CONCLUSION Use of 2Flute (Stryker Corporation) otologic burs for human autologous cortical bone harvest results in more viable bone fragments, with larger bone chips and more osteoblasts. Future studies are needed to determine if this leads to improved bone healing. LEVEL OF EVIDENCE NA. Laryngoscope, 128:E41-E46, 2018.
Collapse
Affiliation(s)
- Adam A Roth
- Department of Otolaryngology-Head and Neck Surgery, Indiana University School of Medicine, Indianapolis, Indiana, U.S.A
| | - Pei-Ciao Tang
- Department of Otolaryngology-Head and Neck Surgery, Indiana University School of Medicine, Indianapolis, Indiana, U.S.A
| | - Michael J Ye
- Department of Medicine, Indiana University School of Medicine, Indianapolis, Indiana, U.S.A
| | - Khalid S Mohammad
- Department of Medicine, Indiana University School of Medicine, Indianapolis, Indiana, U.S.A
| | - Rick F Nelson
- Department of Otolaryngology-Head and Neck Surgery, Indiana University School of Medicine, Indianapolis, Indiana, U.S.A
| |
Collapse
|
22
|
Vedantam A, Hansen D, Briceño V, Brayton A, Jea A. Patient-reported outcomes of occipitocervical and atlantoaxial fusions in children. J Neurosurg Pediatr 2017; 19:85-90. [PMID: 27791706 DOI: 10.3171/2016.8.peds16286] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE There is limited literature on patient-reported outcomes (PROs) and health-related quality of life (HRQOL) outcomes in pediatric patients undergoing surgery for craniovertebral junction pathology. The aim of the present study was to assess surgical and quality of life outcomes in children who had undergone occipitocervical or atlantoaxial fusion. METHODS The authors retrospectively reviewed the demographics, procedural data, and outcomes of 77 consecutive pediatric patients who underwent posterior occipitocervical or atlantoaxial fusion between 2008 and 2015 at Texas Children's Hospital. Outcome measures (collected at last follow-up) included mortality, neurological improvement, complications, Scoliosis Research Society Outcomes Measure-22 (SRS-22) score, SF-36 score, Neck Disability Index (NDI), and Pediatric Quality of Life Inventory (PedsQL). Multivariate linear regression analysis was performed to identify factors affecting PROs and HRQOL scores at follow-up. RESULTS The average age in this series was 10.6 ± 4.5 years. The median follow-up was 13.9 months (range 0.5-121.5 months). Sixty-three patients (81.8%) were treated with occipitocervical fusion, and 14 patients (18.1%) were treated with atlantoaxial fusion. The American Spinal Injury Association (ASIA) grade at discharge was unchanged in 73 patients (94.8%). The average PRO metrics at the time of last follow-up were as follows: SRS-22 score, 4.2 ± 0.8; NDI, 3.0 ± 2.6; the parent's PedsQL (ParentPedsQL) score, 69.6 ± 22.7, and child's PedsQL score, 75.5 ± 18.7. Multivariate linear regression analysis revealed that older age at surgery was significantly associated with lower SRS-22 scores at follow-up (B = -0.06, p = 0.03), and the presence of comorbidities was associated with poorer ParentPedsQL scores at follow-up (B = -19.68, p = 0.03). CONCLUSIONS This study indicates that occipitocervical and atlantoaxial fusions in children preserve neurological function and are associated with acceptable PROs and ParentPedsQL scores, considering the serious nature and potential for morbidity in this patient population. However, longer follow-up and disease-specific scales are necessary to fully elucidate the impact of occipitocervical and atlantoaxial fusions on children.
Collapse
Affiliation(s)
- Aditya Vedantam
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; and
| | - Daniel Hansen
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; and
| | - Valentina Briceño
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; and
| | - Alison Brayton
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; and
| | - Andrew Jea
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; and.,Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine Department of Neurosurgery, Goodman Campbell Brain and Spine, Indianapolis, Indiana
| |
Collapse
|
23
|
Martinez-Del-Campo E, Turner JD, Soriano-Baron H, Newcomb AGUS, Kalb S, Theodore N. Pediatric occipitocervical fusion: long-term radiographic changes in curvature, growth, and alignment. J Neurosurg Pediatr 2016; 18:644-652. [PMID: 27472669 DOI: 10.3171/2016.4.peds15567] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The authors assessed the rate of vertebral growth, curvature, and alignment for multilevel constructs in the cervical spine after occipitocervical fixation (OCF) in pediatric patients and compared these results with those in published reports of growth in normal children. METHODS The authors assessed cervical spine radiographs and CT images of 18 patients who underwent occipitocervical arthrodesis. Measurements were made using postoperative and follow-up images available for 16 patients to determine cervical alignment (cervical spine alignment [CSA], C1-7 sagittal vertical axis [SVA], and C2-7 SVA) and curvature (cervical spine curvature [CSC] and C2-7 lordosis angle). Seventeen patients had postoperative and follow-up images available with which to measure vertebral body height (VBH), vertebral body width (VBW), and vertical growth percentage (VG%-that is, percentage change from postoperative to follow-up). Results for cervical spine growth were compared with normal parameters of 456 patients previously reported on in 2 studies. RESULTS Ten patients were girls and 8 were boys; their mean age was 6.7 ± 3.2 years. Constructs spanned occiput (Oc)-C2 (n = 2), Oc-C3 (n = 7), and Oc-C4 (n = 9). The mean duration of follow-up was 44.4 months (range 24-101 months). Comparison of postoperative to follow-up measures showed that the mean CSA increased by 1.8 ± 2.9 mm (p < 0.01); the mean C2-7 SVA and C1-7 SVA increased by 2.3 mm and 2.7 mm, respectively (p = 0.3); the mean CSC changed by -8.7° (p < 0.01) and the mean C2-7 lordosis angle changed by 2.6° (p = 0.5); and the cumulative mean VG% of the instrumented levels (C2-4) provided 51.5% of the total cervical growth (C2-7). The annual vertical growth rate was 4.4 mm/year. The VBW growth from C2-4 ranged from 13.9% to 16.6% (p < 0.001). The VBW of C-2 in instrumented patients appeared to be of a smaller diameter than that of normal patients, especially among those aged 5 to < 10 years and 10-15 years, with an increased diameter at the immediately inferior vertebral bodies compensating for the decreased width. No cervical deformation, malalignment, or detrimental clinical status was evident in any patient. CONCLUSIONS The craniovertebral junction and the upper cervical spine continue to present normal growth, curvature, and alignment parameters in children with OCF constructs spanning a distance as long as Oc-C4.
Collapse
Affiliation(s)
- Eduardo Martinez-Del-Campo
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Jay D Turner
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Hector Soriano-Baron
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Anna G U S Newcomb
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Samuel Kalb
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Nicholas Theodore
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| |
Collapse
|
24
|
Zhou J, Espinoza Orías AA, Kang X, He J, Zhang Z, Inoue N, An HS. CT-based morphometric analysis of the occipital condyle: focus on occipital condyle screw insertion. J Neurosurg Spine 2016; 25:572-579. [DOI: 10.3171/2016.4.spine151431] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE
The segmental occipital condyle screw (OCS) is an alternative fixation technique in occipitocervical fusion. A thorough morphological study of the occipital condyle (OC) is critical for OCS placement. The authors set out to introduce a more precise CT-based method for morphometric analysis of the OC as it pertains to the placement of the segmental OCS, and they describe a novel preoperative simulation method for screw placement. Two new clinically relevant parameters, the height available for the OCS and the warning depth, are proposed.
METHODS
CT data sets from 27 fresh-frozen human cadaveric occipitocervical spines were used. All measurements were performed using a commercially available 3D reconstruction software package. The length, width, and sagittal angle of the condyle were measured in the axial plane at the base of the OC. The height of the OC and the height available for the segmental OCS were measured in the reconstructed oblique sagittal plane, fitting the ideal trajectory of the OCS recommended in the literature. The placement of a 3.5-mm-diameter screw that had the longest length of bicortical purchase was simulated into the OC in the oblique sagittal plane, with the screw path not being blocked by the occiput and not violating the hypoglossal canal cranially or the atlantooccipital joint caudally. The length of the simulated screw was recorded. The warning depth was measured as the shortest distance from the entry point of the screw to the posterior border of the hypoglossal canal.
RESULTS
The mean length and width of the OC were found to be larger in males: 22.2 ± 1.7 mm and 12.1 ± 1.0 mm, respectively, overall (p < 0.0001 for both). The mean sagittal angle was 28.0° ± 4.9°. The height available for the OCS was significantly less than the height of the OC (6.2 ± 1.3 mm vs 9.4 ± 1.5 mm, p < 0.0001). The mean screw length (19.3 ± 1.9 mm) also presented significant sex-related differences: male greater than female (p = 0.0002). The mean warning depth was 7.5 ± 1.7 mm. In 7.4% of the samples, although the height of the OC was viable, the height available for the OCS was less than 4.5 mm, thus making screw placement impractical. For these cases, a new preoperative simulation method of the OCS placement was proposed. In 92.6% of the samples that could accommodate a 3.5-mm-diameter screw, 24.0% showed that the entry point of the simulated screw was covered by a small part of the C-1 posterosuperior joint rim.
CONCLUSIONS
The placement of the segmental OCS is feasible in most cases, but a thorough preoperative radiological analysis is essential and cannot be understated. The height available for the OCS is a more clinically relevant and precise parameter than the height of the OC to enable proper screw placement. The warning depth may be helpful for the placement of the OCS.
Collapse
Affiliation(s)
- Jinsong Zhou
- 1Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
- 2Department of Orthopaedic Surgery, Chengdu Military General Hospital, Chengdu, Sichuan; and
| | | | - Xia Kang
- 2Department of Orthopaedic Surgery, Chengdu Military General Hospital, Chengdu, Sichuan; and
| | - Jade He
- 1Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Zhihai Zhang
- 3Department of Orthopaedic Surgery, Aviation General Hospital, China Medical University, Beijing, People's Republic of China
| | - Nozomu Inoue
- 1Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Howard S. An
- 1Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
25
|
Martinez-Del-Campo E, Turner JD, Rangel-Castilla L, Soriano-Baron H, Kalb S, Theodore N. Pediatric occipitocervical fixation: radiographic criteria, surgical technique, and clinical outcomes based on experience of a single surgeon. J Neurosurg Pediatr 2016; 18:452-462. [PMID: 27286444 DOI: 10.3171/2016.2.peds15544] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE If left untreated, occipitocervical (OC) instability may lead to serious neurological injury or death. Open internal fixation is often necessary to protect the neurovascular elements. This study reviews the etiologies for pediatric OC instability, analyzes the radiographic criteria for surgical intervention, discusses surgical fixation techniques, and evaluates long-term postoperative outcomes based on a single surgeon's experience. METHODS The charts of all patients < 18 years old who underwent internal OC fixation conducted by the senior author were retrospectively reviewed. Forty consecutive patients were identified for analysis. Patient demographic data, OC junction pathology, radiological diagnostic tools, surgical indications, and outcomes are reported. RESULTS The study population consisted of 20 boys and 20 girls, with a mean age of 7.3 years. Trauma (45% [n = 18]) was the most common cause of instability, followed by congenital etiologies (37.5% [n = 15]). The condyle-C1 interval had a diagnostic sensitivity of 100% for atlantooccipital dislocation. The median number of fixated segments was 5 (occiput-C4). Structural bone grafts were used in all patients. Postsurgical neurological improvement was seen in 88.2% (15/17) of patients with chronic myelopathy and in 25% (1/4) of patients with acute myelopathy. Preoperatively, 42.5% (17/40) of patients were neurologically intact and remained unchanged at last follow-up, 42.5% (17/40) had neurological improvement, 12.5% (5/40) remained unchanged, and 2.5% (1/40) deteriorated. All patients had successful fusion at 1-year follow-up. The complication rate was 7.5% (3/40), including 1 case of vertebral artery injury. CONCLUSIONS Occipitocervical fixation is safe in children and provides immediate immobilization, with excellent survival and arthrodesis rates. Of the radiographic tools evaluated, the condyle-C1 interval was the most predictive of atlantooccipital dislocation.
Collapse
Affiliation(s)
- Eduardo Martinez-Del-Campo
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Jay D Turner
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Leonardo Rangel-Castilla
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Hector Soriano-Baron
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Samuel Kalb
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| | - Nicholas Theodore
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
| |
Collapse
|
26
|
Abstract
Instrumentation of the cervical spine enhances stability and improves arthrodesis rates in children undergoing surgery for deformity or instability. Various morphologic and clinical studies have been conducted in children, confirming the feasibility of anterior or posterior instrumentation of the cervical spine with modern implants. Knowledge of the relevant spine anatomy and preoperative imaging studies can aid the clinician in understanding the pitfalls of instrumentation for each patient. Preoperative planning, intraoperative positioning, and adherence to strict surgical techniques are required given the small size of children. Instrumentation options include anterior plating, occipital plating, and a variety of posterior screw techniques. Complications related to screw malposition include injury to the vertebral artery, neurologic injury, and instrumentation failure.
Collapse
|
27
|
Morphologic Analysis of Occipital Sinuses for Occipital Screw Fixation Using Digital Subtraction Angiography. World Neurosurg 2016; 91:279-84. [PMID: 27108024 DOI: 10.1016/j.wneu.2016.04.038] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 04/12/2016] [Accepted: 04/12/2016] [Indexed: 11/22/2022]
Abstract
BACKGROUND Numerous methods to achieve occipitocervical stabilization have been described, including the use of occipital plate/screw constructs. Bicortical screws may increase the pullout strength, but intracranial injuries to venous sinuses have been reported. This study was performed to analyze the variations in occipital sinuses to prevent sinus injury caused by the bicortical screw. METHODS Occipital sinuses of 1720 patients were examined using digital subtraction angiography. The data collected included patient age and sex, occipital sinus type, distance between occipital sinus and midline, depth from inion to occipital sinus, and distance between occipital sinus and midline occiput at different levels. RESULTS The mean age of patients was 57 years ± 13. There were 807 (46.9%) men and 913 (53.1%) women. The most common occipital sinus type was single occipital sinus off-midline (type B2). The least common occipital sinus type was absent occipital sinuses (type A; 8.7% of patients). There was no significant difference between age and occipital sinus type (P = 0.310). Also, the difference between sexes was not significant in regard to occipital sinus type in general. However, in subgroup analysis of type B1 and B2, there was a significant difference between sexes (P < 0.01). The mean depth from bone to occipital sinus was 19.913 mm ± 7.437. CONCLUSIONS The occipital sinus shows several variations, and many morphologic differences can be seen. Preoperative detailed examination by magnetic resonance venography or vertebral angiography may be required for cases in which bicortical occipital screw fixation is necessary to avoid occipital sinus-related complications.
Collapse
|
28
|
Reintjes SL, Amankwah EK, Rodriguez LF, Carey CC, Tuite GF. Allograft versus autograft for pediatric posterior cervical and occipito-cervical fusion: a systematic review of factors affecting fusion rates. J Neurosurg Pediatr 2016; 17:187-202. [PMID: 26496632 DOI: 10.3171/2015.6.peds1562] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Fusion rates are high for children undergoing posterior cervical fusion (PCF) and occipito-cervical fusion (OCF). Autologous bone has been widely used as the graft material of choice, despite the risk of donor-site morbidity associated with harvesting the bone, possibly because very low fusion rates were reported with posterior allograft cervical fusions in children several decades ago. Higher overall fusion rates using allograft in adults, associated with improvements in internal fixation techniques and the availability of osteoinductive substances such as bone morphogenetic protein (BMP), have led to heightened enthusiasm for the use of bank bone during pediatric PCF. A systematic review was performed to study factors associated with successful bone fusion, including the type of bone graft used. METHODS The authors performed a comprehensive PubMed search of English-language articles pertaining to PCF and OCF in patients less than 18 years old. Of the 561 abstracts selected, 148 articles were reviewed, resulting in 60 articles that had sufficient detail to be included in the analysis. A meta-regression analysis was performed to determine if and how age, fusion technique, levels fused, fusion substrate, BMP use, postoperative bracing, and radiographic fusion criteria were related to the pooled prevalence estimates. A systematic review of the literature was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. RESULTS A total of 604 patients met the specific inclusion and exclusion criteria. The overall fusion rate was 93%, with a mean age of 9.3 years and mean follow-up of 38.7 months. A total of 539 patients had fusion with autograft (94% fusion rate) and 65 patients with allograft (80% fusion rate). Multivariate meta-regression analysis showed that higher fusion rates were associated with OCF compared with fusions that excluded the occiput (p < 0.001), with the use of autograft instead of allograft (p < 0.001), and with the use of CT to define fusion instead of plain radiography alone. The type of internal fixation, the use of BMP, patient age, and the duration of follow-up were not found to be associated with fusion rates in the multivariate analysis. CONCLUSIONS Fusion rates for PCF are high, with higher rates of fusion seen when autograft is used as the bone substrate and when the occiput is included in the fusion construct. Further study of the use of allograft as a viable alternative to autograft bone fusion is warranted because limited data are available regarding the use of allograft in combination with more rigid internal fixation techniques and osteoinductive substances, both of which may enhance fusion rates with allograft.
Collapse
Affiliation(s)
- Stephen L Reintjes
- Neuroscience Institute, and.,Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida; and
| | - Ernest K Amankwah
- Department of Clinical and Translational Research, All Children's Hospital/Johns Hopkins Medicine, St. Petersburg
| | - Luis F Rodriguez
- Neuroscience Institute, and.,Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida; and
| | - Carolyn C Carey
- Neuroscience Institute, and.,Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida; and
| | - Gerald F Tuite
- Neuroscience Institute, and.,Department of Neurosurgery and Brain Repair, Morsani College of Medicine, University of South Florida, Tampa, Florida; and.,Department of Pediatrics, Johns Hopkins School of Medicine, Baltimore, Maryland
| |
Collapse
|
29
|
Chang PY, Yen YS, Wu JC, Chang HK, Fay LY, Tu TH, Wu CL, Huang WC, Cheng H. The importance of atlantoaxial fixation after odontoidectomy. J Neurosurg Spine 2016; 24:300-308. [DOI: 10.3171/2015.5.spine141249] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT
Although anterior odontoidectomy has been widely accepted as a procedure for decompression of the craniovertebral junction (CVJ), postoperative biomechanical instability has not been well addressed. There is a paucity of data on the necessity for and choice of fixation.
METHODS
The authors conducted a retrospective review of consecutively treated patients with basilar invagination who underwent anterior odontoidectomy and various types of posterior fixation. Posterior fixation included 1 of 3 kinds of constructs: occipitocervical (OC) fusion with atlantoaxial (AA) fixation, OC fusion without AA fixation, or AA-only (without OC) fixation. On the basis of the use or nonuse of AA fixation, these patients were assigned to either the AA group, in which the posterior fixation surgery involved both the atlas and axis simultaneously, regardless of whether the patient underwent OC fusion, or the non-AA group, in which the OC fusion construct spared the atlas, axis, or both. Clinical outcomes and neurological function were compared. Radiological results at each time point (i.e., before and after odontoidectomy and after fixation) were assessed by calculating the triangular area causing ventral indentation of the brainstem in the CVJ.
RESULTS
Data obtained in 14 consecutively treated patients with basilar invagination were analyzed in this series; the mean follow-up time was 5.75 years. The mean age was 53.58 years; there were 7 males and 7 females. The AA and non-AA groups consisted of 7 patients each. The demographic data of both groups were similar. Overall, there was significant improvement in neurological function after the operation (p = 0.03), and there were no differences in the postoperative Nurick grades between the 2 groups (p = 1.00). According to radiological measurements, significant decompression of the ventral brainstem was achieved stepwise in both groups by anterior odontoidectomy and posterior fixation; the mean ventral triangular area improved from 3.00 ± 0.86 cm2 to 2.08 ± 0.51 cm2 to 1.68 ± 0.59 cm2 (before and after odontoidectomy and after fixation, respectively; p < 0.05). The decompression gained by odontoidectomy (i.e., reduction of the ventral triangular area) was similar in the AA and non-AA groups (0.66 ± 0.42 cm2 vs 1.17 ± 1.42 cm2, respectively; p = 0.38). However, the decompression achieved by posterior fixation was significantly greater in the AA group than in the non-AA group (0.64 ± 0.39 cm2 vs 0.17 ± 0.16 cm2, respectively; p = 0.01).
CONCLUSIONS
Anterior odontoidectomy alone provides significant decompression at the CVJ. Adjuvant posterior fixation further enhances the extent of decompression after the odontoidectomy. Moreover, posterior fixation that involves AA fixation yields significantly more decompression of the ventral brainstem than OC fusion that spares AA fixation.
Collapse
Affiliation(s)
- Peng-Yuan Chang
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
| | - Yu-Shu Yen
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
| | - Jau-Ching Wu
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
| | - Hsuan-Kan Chang
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
| | - Li-Yu Fay
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
- 4Institute of Pharmacology, National Yang-Ming University; and
| | - Tsung-Hsi Tu
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
- 5Molecular Medicine Program, Taiwan International Graduate Program, Academia Sinica, Taipei, Taiwan
| | - Ching-Lan Wu
- 2Department of Radiology, Taipei Veterans General Hospital
- 3School of Medicine and
| | - Wen-Cheng Huang
- 1Department of Neurosurgery, Neurological Institute, and
- 3School of Medicine and
| | - Henrich Cheng
- 1Department of Neurosurgery, Neurological Institute, and
- 2Department of Radiology, Taipei Veterans General Hospital
- 3School of Medicine and
| |
Collapse
|
30
|
Martinez-Del-Campo E, Kalb S, Soriano-Baron H, Turner JD, Neal MT, Uschold T, Theodore N. Computed tomography parameters for atlantooccipital dislocation in adult patients: the occipital condyle-C1 interval. J Neurosurg Spine 2015; 24:535-45. [PMID: 26682597 DOI: 10.3171/2015.6.spine15226] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Atlantooccipital dislocation (AOD) in adults cannot be diagnosed with adequate specificity and sensitivity using only CT or plain radiography, and the spine literature offers no guidelines. In children, the most sensitive and specific radiographic measurement for the diagnosis of AOD is the CT-based occipital condyle-C1 interval (CCI). The goal of the current study was to identify the normal CCI in healthy adults and compare it with the CCI in adults with AOD to establish a highly sensitive and specific cutoff value for the neuroimaging diagnosis of AOD. METHODS A total of 81 patients, 59 without AOD and 22 with AOD, were included in this study. Measurements obtained from thin-slice CT scans of the craniovertebral joint to assess atlantooccipital dislocation included the CCI, condylar sum, the Wholey and Harris intervals, Powers and Sun ratios, Wackenheim line, and Lee X-lines. RESULTS The group of patients without AOD included 30 men (50.8%) and 29 women (49.2%) with a mean age of 42.4 ± 16 years (range 19-87 years). The group of patients with AOD included 10 men (45.5%) and 12 women (54.5%) with a mean age of 38.2 ± 9.7 years (range 20-56 years). Interrater reliabilities within a 95% CI were all greater than 0.98 for CCI measurements. A total of 1296 measurements of the CCI were made in 81 patients. The mean CCI for non-AOD patients was 0.89 ± 0.12 mm, the single largest CCI measurement was 1.4 mm, and the largest mean for either right or left CCI was 1.2 mm. The mean condylar sum was 1.8 ± 0.2 mm, and the largest condylar sum value was 2.2 mm. Linear regression with age predicted an increase in CCI of 0.001 mm/year (p < 0.05). The mean CCI in AOD patients was 3.35 ± 0.18 mm (range 1.5 mm-6.4 mm). The shortest single CCI measurements in the AOD patients were 1.1 mm and 1.2 mm. The mean condylar sum for all 22 AOD patients was 6.7 ± 2.7 mm and the shortest condylar sums were 3.0 mm. Cutoff values for AOD were set at 1.5 mm for the CCI and 3.0 mm for the condylar sum, both with a sensitivity of 1 and false-negative rate of 0. Sensitivity for the Powers, Wholey, Harris, Sun, Wackenheim, and Lee criteria were determined to be 0.55, 0.46, 0.27, 0.23, 0.41, and 0.41, respectively. CONCLUSIONS The CCI is shorter in adult patients as opposed to the pediatric population. The revised CCI (1.5 mm) and condylar sum (3.0 mm) cutoff values have the highest sensitivity and specificity for the diagnosis of AOD in the adult population.
Collapse
Affiliation(s)
- Eduardo Martinez-Del-Campo
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Samuel Kalb
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Hector Soriano-Baron
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Jay D Turner
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Matthew T Neal
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| | - Timothy Uschold
- Southern Oregon Neurosurgical and Spine Associates, Medford, Oregon
| | - Nicholas Theodore
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and
| |
Collapse
|
31
|
Gressot LV, Mata JA, Luerssen TG, Jea A. Surgical treatment of congenital thoracolumbar spondyloptosis in a 2-year-old child with vertebral column resection and posterior-only circumferential reconstruction of the spine column: case report. J Neurosurg Pediatr 2015; 15:207-13. [PMID: 25495210 DOI: 10.3171/2014.9.peds14151] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Spondyloptosis refers to complete dislocation of a vertebral body onto another. The L5-S1 level is frequently affected. As this condition is rare, few published reports describing its clinical features and surgical outcomes exist, especially in the pediatric patient population. The authors report the presentation, pathological findings, and radiographic studies of a 2-year-old girl who presented to Texas Children's Hospital with a history since birth of progressive spastic paraparesis. Preoperative CT and MRI showed severe spinal cord compression associated with T11-12 spondyloptosis. The patient underwent a single-stage posterior approach for complete resection of the dysplastic vertebral bodies at the apex of the spinal deformity with reconstruction and stabilization of the vertebral column using a titanium expandable cage and pedicle screws. At the 12-month follow-up, the patient remained neurologically stable without any radiographic evidence of instrumentation failure or loss of alignment. To the best of the authors' knowledge, there have been only 2 other children with congenital thoracolumbar spondyloptosis treated with the above-described strategy. The authors describe their case and review the literature to discuss the aggregate clinical features, surgical strategies, and operative outcomes for congenital thoracolumbar spondyloptosis.
Collapse
Affiliation(s)
- Loyola V Gressot
- Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | | | | | | |
Collapse
|
32
|
Mazur MD, Sivakumar W, Riva-Cambrin J, Jones J, Brockmeyer DL. Avoiding early complications and reoperation during occipitocervical fusion in pediatric patients. J Neurosurg Pediatr 2014; 14:465-75. [PMID: 25171720 DOI: 10.3171/2014.7.peds1432] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Surgical arthrodesis for pediatric occipitocervical (OC) instability has a high rate of success in a wide variety of challenging circumstances; however, identifying potential risk factors can help to target variables that should be the focus of improvement. The aim of this paper was to examine risk factors predictive of failure in a population of patients who underwent instrumented OC arthrodesis using a uniform surgical philosophy. METHODS The authors conducted a retrospective cohort study of pediatric patients who underwent OC fusion from 2001 to 2013 at a single institution to determine risk factors for surgical failure, defined as reoperation for revision of the arthrodesis or instrumentation. The primary study outcome was either radiographic confirmation of successful OC fusion or surgical failure requiring revision of the arthrodesis or instrumentation. The secondary outcome was the underlying cause of failure (hardware failure, graft failure, or infection). Univariate analysis was performed to assess the association between outcome and patient demographics, cause of OC instability, type of OC instrumentation, bone graft material, biological adjuncts, and complications. RESULTS Of the 127 procedures included, 20 (15.7%) involved some form of surgical failure and required revision surgery. Univariate analysis revealed that patients with deep wound infections requiring debridement were more likely to require surgical revision of the hardware or graft (p = 0.002). Subgroup analysis revealed that patients with skeletal dysplasia or congenital spinal anomalies were more likely to develop hardware failure than patients with other causes of OC instability (p = 0.020). Surgical failure was not associated with the method of C-2 fixation, type of rigid OC instrumentation, bone graft material, use of bone morphogenetic protein or biological adjuncts, cause of instability, sex, age, or having previous OC fusion operations. CONCLUSIONS Pediatric patients in the present cohort with postoperative wound infections requiring surgical debridement had higher surgical failure rates after OC fusion. Those with skeletal dysplasia and congenital spinal anomalies were more likely to require reoperation for hardware failure. Better understanding of the mode of surgical failure may enable surgeons to develop strategies to decrease the need for reoperation in pediatric patients with OC instability.
Collapse
Affiliation(s)
- Marcus D Mazur
- Department of Neurosurgery, Division of Pediatric Neurosurgery, Primary Children's Hospital, University ofUtah, Salt Lake City, Utah; and
| | | | | | | | | |
Collapse
|
33
|
Savage JG, Fulkerson DH, Sen AN, Thomas JG, Jea A. Fixation with C-2 laminar screws in occipitocervical or C1-2 constructs in children 5 years of age or younger: a series of 18 patients. J Neurosurg Pediatr 2014; 14:87-93. [PMID: 24784980 DOI: 10.3171/2014.3.peds13626] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
UNLABELLED OBJECT.: There are rare indications for upper cervical spine fusion in young children. Compared with nonrigid constructs, rigid instrumentation with screw fixation increases the fusion rate and reduces the need for halo fixation. Instrumentation may be technically challenging in younger children. A number of screw placement techniques have been described. Use of C-2 translaminar screws has been shown to be anatomically feasible, even in the youngest of children. However, there are few data detailing the clinical outcome. In this study, the authors describe the clinical and radiographic follow-up of 18 children 5 years of age or younger who had at least one C-2 translaminar screw as part of an occipitocervical or C1-2 fusion construct. METHODS A retrospective review of all children treated with instrumented occipitocervical or C1-2 fusion between July 1, 2007, and June 30, 2013, at Riley Children's Hospital and Texas Children's Hospital was performed. All children 5 years of age or younger with incorporation of at least one C-2 translaminar screw were identified. RESULTS Eighteen children were studied (7 boys and 11 girls). The mean age at surgery was 38.1 months (range 10-68 months). Indications for surgery included traumatic instability (6), os odontoideum (3), destructive processes (2), and congenital instability (7). A total of 24 C-2 translaminar screws were placed; 23 (95.8%) of 24 were satisfactorily placed (completely contained within the cortical walls). There was one medial cortex breach without neurological impingement. There were no complications with screw placement. Three patients required wound revisions. Two patients died as a result of their original condition (trauma, malignant tumor). The mean follow-up duration for the surviving patients was 17.5 months (range 3-60 months). Eleven (91.7%) of the 12 patients followed for 6 months or longer showed radiographic stability or completed fusion. CONCLUSIONS Use of C-2 translaminar screws provides an effective anchor for internal fixation of the upper cervical spine. In this study of children 5 years of age or younger, the authors found a high rate of radiographic fusion with a low rate of complications.
Collapse
Affiliation(s)
- Jennifer G Savage
- Division of Pediatric Neurosurgery, Department of Neurological Surgery, Goodman Campbell Brain and Spine, Indiana University School of Medicine, Indianapolis, Indiana; and
| | | | | | | | | |
Collapse
|
34
|
The causes and treatment strategies for the postoperative complications of occipitocervical fusion: a 316 cases retrospective analysis. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2014; 23:1720-4. [DOI: 10.1007/s00586-014-3354-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 04/27/2014] [Accepted: 04/27/2014] [Indexed: 11/26/2022]
|
35
|
Kosnik-Infinger L, Glazier SS, Frankel BM. Occipital condyle to cervical spine fixation in the pediatric population. J Neurosurg Pediatr 2014; 13:45-53. [PMID: 24206344 DOI: 10.3171/2013.9.peds131] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Fixation at the craniovertebral junction (CVJ) is necessary in a variety of pediatric clinical scenarios. Traditionally an occipital bone to cervical fusion is preformed, which requires a large amount of hardware to be placed on the occiput of a child. If a patient has previously undergone a posterior fossa decompression or requires a decompression at the time of the fusion procedure, it can be difficult to anchor a plate to the occipital bone. The authors propose a technique that can be used when faced with this difficult challenge by using the occipital condyle as a point of fixation for the construct. Adult cadaveric and a limited number of case studies have been published using occipital condyle (C-0) fixation. This work was adapted for the pediatric population. Between 2009 and 2012, 4 children underwent occipital condyle to axial or subaxial spine fixation. One patient had previously undergone posterior fossa surgery for tumor resection, and 1 required decompression at the time of operation. Two patients underwent preoperative deformity reduction using traction. One child had a Chiari malformation Type I. Each procedure was performed using polyaxial screw-rod constructs with intraoperative neuronavigation supplemented by a custom navigational drill guide. Smooth-shanked 3.5-mm polyaxial screws, ranging in length from 26 to 32 mm, were placed into the occipital condyles. All patients successfully underwent occipital condyle to cervical spine fixation. In 3 patients the construct extended from C-0 to C-2, and in 1 from C-0 to T-2. Patients with preoperative halo stabilization were placed in a cervical collar postoperatively. There were no new postoperative neurological deficits or vascular injuries. Each patient underwent postoperative CT, demonstrating excellent screw placement and evidence of solid fusion. Occipital condyle fixation is an effective option in pediatric patients requiring occipitocervical fusion for treatment of deformity and/or instability at the CVJ. The use of intraoperative neuronavigation allows for safe placement of screws into C-0, especially when faced with a challenging patient in whom fixation to the occipital bone is not possible or is less than ideal.
Collapse
Affiliation(s)
- Libby Kosnik-Infinger
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina; and
| | | | | |
Collapse
|
36
|
Chalouhi N, Chitale A, Tjoumakaris S, Gonzalez LF, Theofanis T, Jabbour P. Cerebellar hemorrhage from a delayed cervical spine hardware migration. Clin Neurol Neurosurg 2013; 115:1894-6. [DOI: 10.1016/j.clineuro.2013.05.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Revised: 04/20/2013] [Accepted: 05/05/2013] [Indexed: 11/15/2022]
|
37
|
Epstein NE. A review article on the diagnosis and treatment of cerebrospinal fluid fistulas and dural tears occurring during spinal surgery. Surg Neurol Int 2013; 4:S301-17. [PMID: 24163783 PMCID: PMC3801173 DOI: 10.4103/2152-7806.111427] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Accepted: 03/25/2013] [Indexed: 02/06/2023] Open
Abstract
Background: In spinal surgery, cerebrospinal fluid (CSF) fistulas attributed to deliberate dural opening (e.g., for tumors, shunts, marsupialization of cysts) or inadvertent/traumatic dural tears (DTs) need to be readily recognized, and appropriately treated. Methods: During spinal surgery, the dura may be deliberately opened to resect intradural lesions/tumors, to perform shunts, or to open/marsupialize cysts. DTs, however, may inadvertently occur during primary, but are seen more frequently during revision spinal surgery often attributed to epidural scarring. Other etiologies of CSF fistulas/DTs include; epidural steroid injections, and resection of ossification of the posterior longitudinal ligament (OPLL) or ossification of the yellow ligament (OYL). Whatever the etiology of CSF fistulas or DTs, they must be diagnosed utilizing radioisotope cisternography (RIC), magnetic resonance imaging (MRI), computed axial tomography (CT) studies, and expeditiously repaired. Results: DTs should be repaired utilizing interrupted 7-0 Gore-Tex (W.L. Gore and Associates Inc., Elkton, MD, USA) sutures, as the suture itself is larger than the needle; the larger suture occludes the dural puncture site. Closure may also include muscle patch grafts, dural patches/substitutes (bovine pericardium), microfibrillar collagen (Duragen: Integra Life Sciences Holdings Corporation, Plainsboro, NJ), and fibrin glues or dural sealants (Tisseel: Baxter Healthcare Corporation, Deerfield, IL, USA). Only rarely are lumbar drains and wound-peritoneal and/or lumboperitoneal shunts warranted. Conclusion: DTs or CSF fistulas attributed to primary/secondary spinal surgery, trauma, epidural injections, OPLL, OYL, and other factors, require timely diagnosis (MRI/CT/Cisternography), and appropriate reconstruction.
Collapse
Affiliation(s)
- Nancy E Epstein
- Clinical Professor of Neurological Surgery, Department of Neurosurgery, The Albert Einstein College of Medicine, Bronx, NY, 10461, and Chief of Neurosurgical Spine and Education, Department of Neurosurgery, Winthrop University Hospital, Mineola, NY, 11501, USA
| |
Collapse
|
38
|
Ling JM, Tiruchelvarayan R, Seow WT, Ng HB. Surgical treatment of adult and pediatric C1/C2 subluxation with intraoperative computed tomography guidance. Surg Neurol Int 2013; 4:S109-17. [PMID: 23646272 PMCID: PMC3642753 DOI: 10.4103/2152-7806.109454] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Accepted: 01/28/2013] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Surgical treatment of C1/C2 subluxation has evolved significantly over the past 2 decades, from the relatively simpler posterior wiring to more technically demanding instrumentations such as C1 lateral mass screws - C2 pedicle screws, C1/C2 transarticular screws, and occipital cervical fusion. Navigation with fluoroscopy is currently the standard of practice in most centers. However, fluoroscopy at this level carries several major drawbacks, such as blockage by the mandible and inability to produce axial images for assessment of the reduction of rotatory subluxation. METHODS The authors report a series of 21 patients with C1/C2 subluxation treated surgically with intraoperative computed tomography (ICT) guidance. RESULTS There were 7 children and 14 adults. Eight patients underwent C1/C2 fixation with a Harm's construct, and 13 patients underwent occipital cervical fusion. One out of 17 (6%) C1 lateral mass screws has breached the medial wall of lateral mass by 1 mm. Two out of 20 (10%) C2 pedicle screws have breached the foramen transversarium by 1 mm (Neo classification grade 1). The position of all subaxial screws (49 lateral mass screws and 13 pedicle screws) and occipital screws (50 screws) appeared satisfactory. No neurovascular damage occurred in all the patients. CONCLUSIONS Ninety eight percent of the screws were placed in ideal position with the aid of ICT. Only 2% of the screws deviated from the planned position, but the breaches were not clinically significant and hence no revision was required. This showed that ICT guidance can help to achieve a high accuracy of surgical instrumentation for the treatment of C1/C2 subluxation.
Collapse
Affiliation(s)
- Ji Min Ling
- Department of Neurosurgery, National Neuroscience Institute of Singapore, 11 Jalan Tan Tock Seng, 308433, Singapore
| | | | | | | |
Collapse
|