1
|
Shu L, Xiao B, Jiang Y, Tang S, Yan T, Wu Y, Wu M, Lv S, Lai X, Zhu X, Hu P, Ye M. Comparison of LVIS and Enterprise stent-assisted coiling embolization for ruptured intracranial aneurysms: a propensity score-matched cohort study. Neurosurg Rev 2024; 47:560. [PMID: 39242449 DOI: 10.1007/s10143-024-02756-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 06/24/2024] [Accepted: 08/23/2024] [Indexed: 09/09/2024]
Abstract
The role of a low-profile visualized intraluminal support stent (LVIS) and Enterprise in the treatment of unruptured intracranial aneurysms is well established. Although previous studies have investigated one single type of stent for the treatment of ruptured intracranial aneurysms (RIA), the safety and efficacy between the two types of stents has not been fully explored. Herein we conducted a study to compare the outcomes of the two stents for treatment of RIA. This is a prospective registry database of aneurysmal subarachnoid hemorrhage (aSAH) patients admitted to a single institution between 2018 and 2021. We collected patient baseline information, secondary complications, follow-up angiographic data, long-term prognostic outcomes, and conducted propensity score matching (PSM) analysis with 1:1 ratio and a multivariable logistic regression to compare the outcomes of the two types of stents. A total of 231 patients with RIAs were included in this study, with 108 treated using the LVIS device and 123 treated using the Enterprise device. Before PSM analysis, only the incidence of poor prognosis after 12 months was higher in the Enterprise group comparing to the LVIS group (20% vs. 10%, P = 0.049). After PSM analysis, there was a higher occurrence of delayed cerebral ischemia (DCI) in the Enterprise group compared to the LVIS group (odds ratio [OR] 3.95, 95% confidence interval [CI] [1.20-13.01], P = 0.024). However, no significant difference in prognosis was observed after PSM adjustment. Furthermore, subgroup analysis revealed that patients with female (P = 0.019), hypertension (P = 0.048), and anterior circulation aneurysms (P = 0.019) receiving the Enterprise device had a higher risk of DCI. The overall efficacy of LVIS and Enterprise in the treatment of RIA is comparable, while the incidence of DCI in the LVIS group is lower than that in the Enterprise group after PSM analysis. Registration number: NCT05738083 ( https://clinicaltrials.gov/ ).
Collapse
Affiliation(s)
- Lei Shu
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
- Jiangxi Key Laboratory of Neurological Tumors and Cerebrovascular Diseases, Nanchang, 330006, Jiangxi, China
- Jiangxi Health Commission Key Laboratory of Neurological Medicine, Nanchang, 330006, Jiangxi, China
- Institute of Neuroscience, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Bing Xiao
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Yuan Jiang
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Shiliang Tang
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Tengfeng Yan
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
- Jiangxi Key Laboratory of Neurological Tumors and Cerebrovascular Diseases, Nanchang, 330006, Jiangxi, China
- Jiangxi Health Commission Key Laboratory of Neurological Medicine, Nanchang, 330006, Jiangxi, China
- Institute of Neuroscience, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Yanze Wu
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
- Jiangxi Key Laboratory of Neurological Tumors and Cerebrovascular Diseases, Nanchang, 330006, Jiangxi, China
- Jiangxi Health Commission Key Laboratory of Neurological Medicine, Nanchang, 330006, Jiangxi, China
- Institute of Neuroscience, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Miaojing Wu
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Shigang Lv
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Xianliang Lai
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Xingen Zhu
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China
- Jiangxi Key Laboratory of Neurological Tumors and Cerebrovascular Diseases, Nanchang, 330006, Jiangxi, China
- Jiangxi Health Commission Key Laboratory of Neurological Medicine, Nanchang, 330006, Jiangxi, China
- Institute of Neuroscience, Nanchang University, Nanchang, 330006, Jiangxi, China
| | - Ping Hu
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China.
- Department of Neurosurgery, Panzhihua Central Hospital, The Second Clinical Medical College, Panzhihua University, Panzhihua, 617067, Sichuan, China.
- Clinical Medical Research Center, Panzhihua Central Hospital, Panzhihua, 617067, Sichuan, China.
| | - Minhua Ye
- Department of Neurosurgery, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, Jiangxi, China.
| |
Collapse
|
2
|
Luo B, Wang C, Liu J, Zhang Y, Wang K, Li W, Zhang Y. Treatment of basilar artery aneurysms with two braided stents: Two centers experience of low-profile visualized intraluminal support stents versus Pipeline flow diverters. Neuroradiol J 2024; 37:500-509. [PMID: 38547230 PMCID: PMC11366196 DOI: 10.1177/19714009241242638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024] Open
Abstract
BACKGROUND Both low-profile visualized intraluminal support (LVIS)stents and Pipeline flow diverters (FDs) are therapeutic strategies for basilar artery (BA) aneurysms, but they have not been directly compared. METHODS A total of 132 consecutive patients with 139 BA aneurysms treated with either LVIS stent or Pipeline FDs were analyzed. Propensity score matching (PSM) was used to control for age, sex, hypertension, aneurysm size, shape, location, and duration of follow-up. The treatment results of these two braided stents were compared. RESULTS LVIS stent was placed in 88 (63.3%) and Pipeline FDs in 51 (36.7%) procedures. Patients with Pipeline FDs tended to be younger and have less hypertension, whereas aneurysms had larger aneurysm size. After PSM, similar complete or near-complete occlusion rates (76.7% vs 73.3%, p = .766) and favorable functional outcomes (86.7% vs 90.0%, p = 1) were achieved in patients treated with LVIS stents and Pipeline FDs, respectively. Further comparisons were conducted at three different locations (basilar apex/basilar trunk/vertebrobasilar artery junction [VBJ]) separately, and the results showed a higher complete or near-complete aneurysm occlusion rate after Pipeline FD treatment than LVIS treatment (86.7% vs 59.2%, p = .012) only at VBJ, where a particularly high proportion of non-saccular shape (70.9%) and a male preponderance were noted. CONCLUSION Both braided stents were effective in the treatment of BA aneurysms, with good occlusion rates and favorable functional outcomes. Pipeline FD achieved a particularly higher aneurysm occlusion rate than LVIS stent at VBJ, where lesions often require reconstruction of the diseased vessel.
Collapse
Affiliation(s)
- Bin Luo
- Department of Neurosurgery, Peking University International Hospital, Beijing, China
| | - Chao Wang
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Jian Liu
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yisen Zhang
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Kun Wang
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Wenqiang Li
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Ying Zhang
- Department of Interventional Neuroradiology and Department of Neurosurgery, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
3
|
Forestier G, Piotin M, Chau Y, Derelle AL, Brunel H, Aggour M, Saleme S, Levrier O, Pierot L, Barreau X, Boubagra K, Janot K, Barbier C, Clarençon F, Chabert E, Spelle L, Arteaga C, Consoli A, Machi P, Blanc R, Rodesch G, Cortese J, Sourour N, Herbreteau D, Heck O, Soize S, Marnat G, Rouchaud A, Anxionnat R, Sedat J, Mounayer C. Safety and effectiveness of the LVIS and LVIS Jr devices for the treatment of intracranial aneurysms: Final results of the LEPI multicenter cohort study. J Neuroradiol 2024; 51:242-248. [PMID: 37858720 DOI: 10.1016/j.neurad.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 10/16/2023] [Accepted: 10/16/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND The Low profile visualized intraluminal support (LVIS)/LVIS Jr is a self-expanding braiding stent for the treatment of intracranial aneurysm. This study is to determine the safety and effectiveness of the LVIS/LVIS Jr for the treatment of intracranial aneurysms in a real-world setting. METHODS This prospective, observational, multicenter study enrolled patients with unruptured, ruptured and recanalized intracranial aneurysms treated with the LVIS stents, between February 2018 to December 2019. Primary endpoint was the cumulative morbidity and mortality rate (CMMR) assessed at 12 months follow-up (FU). RESULTS A total of 130 patients were included (62.3 % women, mean age 55.9 ± 11.4) on an intention-to-treat basis. Four patients (3.1 %) had 2 target aneurysms; 134 total aneurysms were treated. The aneurysms were mainly located on the middle cerebral artery (41/134; 30.6 %) and the anterior communicating artery (31/134; 23.1 %). The CMMR at 1 year linked to the procedure and/or device was 4.6 % (6/130). The overall mortality was 1.5 % (2/130), none of these deaths adjudged as being linked to the procedure and/or device. All aneurysms (134/134, 100 %) were successfully treated with LVIS stent and/or other devices. At a mean FU of 16.8 months post-procedure, complete/nearly complete occlusion was achieved in 112 aneurysms (92.6 %), and only 3 patients (2.5 %) required aneurysm retreatment. CONCLUSION This study provides evidence that the LVIS/LVIS Jr devices are safe and effective in the treatment of complex intracranial aneurysms, with very high rates of adequate occlusion at FU. These angiographic results are stable over time with an acceptable complication rate. TRIAL REGISTRATION ClinicalTrial.gov under NCT03553771.
Collapse
Affiliation(s)
- Géraud Forestier
- Neuroradiology Department, University Hospital of Limoges, Dupuytren, Limoges, France.
| | - Michel Piotin
- Department of Interventional Neuroradiology, FHU NeuroVasc, Adolphe de Rothschild Foundation Hospital, Paris, France; Laboratory for Vascular Translational Science UMRS 1148, INSERM, Paris, France
| | - Yves Chau
- Department of Neuro-Interventional and Vascular Interventional, University Hospital of Nice, Nice, France
| | - Anne-Laure Derelle
- Department of Diagnostic and Therapeutic Neuroradiology, CHRU-Nancy, Université de Lorraine, Nancy, France
| | - Hervé Brunel
- Department of Neuroradiology, APHM, Marseille, France
| | - Mohammed Aggour
- Department of Neuroradiology, University Hospital of Saint-Étienne, Saint-Étienne, France
| | - Suzana Saleme
- Neuroradiology Department, University Hospital of Limoges, Dupuytren, Limoges, France
| | - Olivier Levrier
- Department of Interventional Neuroradiology, Polyclinique Clairval, Marseille, France
| | - Laurent Pierot
- Department of Interventional Neuroradiology, University Hospital of Reims, Reims, France
| | - Xavier Barreau
- Department of Interventional Neuroradiology, Pellegrin Hospital, University Hospital of Bordeaux, Bordeaux, France
| | - Kamel Boubagra
- Department of Interventional Neuroradiology, University Hospital of Grenoble, Grenoble, France
| | - Kévin Janot
- Department of Diagnostic and Interventional Neuroradiology, Tours University Hospital, Tours, France
| | - Charlotte Barbier
- Department of Diagnostic and Interventional Neuroradiology, University Hospital of Caen, Caen, France
| | - Frédéric Clarençon
- Department of Interventional Neuroradiology, Sorbonne University, AP-HP, Pitié Salpêtrière - Charles Foix Hospital, Paris, France; GRC BioFast, Sorbonne University, Paris VI, France
| | - Emmanuel Chabert
- Department of Diagnostic and Interventional Neuroradiology, University Hospital of Clermont-Ferrrand, Clermont-Ferrand, France
| | - Laurent Spelle
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University-Hospital, Le Kremlin-Bicetre, France
| | | | - Arturo Consoli
- Interventional and Diagnostic Neuroradiology, Foch Hospital, University of Versailles Saint-Quentin-des-Yvelines, France
| | - Paolo Machi
- Diagnostic and Interventional Neuroradiology department, Geneva University Hospitals, Geneva, Switzerland
| | - Raphaël Blanc
- Department of Interventional Neuroradiology, FHU NeuroVasc, Adolphe de Rothschild Foundation Hospital, Paris, France; Laboratory for Vascular Translational Science UMRS 1148, INSERM, Paris, France
| | - Georges Rodesch
- Interventional and Diagnostic Neuroradiology, Foch Hospital, University of Versailles Saint-Quentin-des-Yvelines, France
| | - Jonathan Cortese
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University-Hospital, Le Kremlin-Bicetre, France; Faculty of Medicine, Paris-Saclay University, INSERM U1195, Le Kremlin-Bicetre, France
| | - Nader Sourour
- Department of Interventional Neuroradiology, Sorbonne University, AP-HP, Pitié Salpêtrière - Charles Foix Hospital, Paris, France
| | - Denis Herbreteau
- Department of Diagnostic and Interventional Neuroradiology, Tours University Hospital, Tours, France
| | - Olivier Heck
- Department of Interventional Neuroradiology, University Hospital of Grenoble, Grenoble, France
| | - Sébastien Soize
- Department of Interventional Neuroradiology, University Hospital of Reims, Reims, France
| | - Gaultier Marnat
- Department of Interventional Neuroradiology, Pellegrin Hospital, University Hospital of Bordeaux, Bordeaux, France
| | - Aymeric Rouchaud
- Neuroradiology Department, University Hospital of Limoges, Dupuytren, Limoges, France; CNRS, XLIM, UMR 7252, Limoges 87000, France
| | - René Anxionnat
- Department of Diagnostic and Therapeutic Neuroradiology, CHRU-Nancy, Université de Lorraine, Nancy, France
| | - Jacques Sedat
- Department of Neuro-Interventional and Vascular Interventional, University Hospital of Nice, Nice, France
| | - Charbel Mounayer
- Neuroradiology Department, University Hospital of Limoges, Dupuytren, Limoges, France; CNRS, XLIM, UMR 7252, Limoges 87000, France
| |
Collapse
|
4
|
Nejadhamzeeigilani H, Buende T, Saleem N, Goddard T, Patankar T. Single centre experience of stent-assisted coiling of wide-necked basilar tip aneurysms. Br J Radiol 2023; 96:20220504. [PMID: 37660365 PMCID: PMC10607421 DOI: 10.1259/bjr.20220504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/03/2023] [Accepted: 07/14/2023] [Indexed: 09/05/2023] Open
Abstract
OBJECTIVE To report clinical and radiological follow-up outcomes of stent-assisted coiling of wide-necked basilar tip aneurysms and to evaluate the safety and efficacy of this treatment choice. METHODS A retrospective review was carried out of 19 patients with wide-necked basilar tip aneurysms in our institution between 2010 and 2020. The rates of perioperative complication, morbidity, mortality, imaging follow-up and re-treatment were analysed. RESULTS Our technical complication rate was 11% but did not result in treatment failure. The combined procedure related morbidity and mortality rate of the 19 patients who underwent stent assisted coiling was also 11%. 16 of 19 patients had undergone angiographic follow-up with a mean period of 32 months. 81% of patients with angiographic follow-up had a satisfactory occlusion (RROI or II) with 11% requiring re-treatment. Those requiring re-treatment were both treated with laser-cut stents; this is in contrast with no re-treatments required in the patients treated with braided stents. CONCLUSION Our report provides acceptable outcomes in wide-necked basilar termination aneurysms which are very challenging to treat. Aneurysms treated with braided stents had better efficacy outcomes than those with laser-cut stents. ADVANCES IN KNOWLEDGE Given the emergent and increasing utility of alternative endovascular techniques such as intrasaccular devices and flow diverters, real-world data are lacking on more conventional approaches such stent-assisted coiling, especially so in the posterior circulation. The associated relatively higher aneurysmal haemorrhagic risk in this location warrants further additional safety and efficacy data for this treatment approach, which this paper provides.
Collapse
Affiliation(s)
- Hamed Nejadhamzeeigilani
- Department of Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Thierry Buende
- Department of Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Nayyar Saleem
- Department of Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Tony Goddard
- Department of Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Tufail Patankar
- Department of Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| |
Collapse
|
5
|
Capirossi C, Radu RA, Gascou G, Lefevre PH, Dargazanli C, Machi P, Costalat V, Cagnazzo F. Safety and efficacy of braided stents as stent monotherapy for the treatment of small intracranial aneurysms. Interv Neuroradiol 2023:15910199231208345. [PMID: 37847777 DOI: 10.1177/15910199231208345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2023] Open
Abstract
BACKGROUND The safety and efficacy of low-profile braided stent as stent monotherapy require further investigation. OBJECTIVE To analyze patient outcomes after treatment with braided stents used as "light" flow diverters. MATERIAL/METHODS Retrospective study to evaluate the occlusion rate of aneurysms treated with braided stent and remodeling of covered side branches and perforators. Several factors potentially influencing aneurysm occlusion were analyzed. RESULTS Thirty-five aneurysms in 31 patients were included. Six aneurysms (17.1%) had an acute subarachnoid hemorrhage. Braided stent was used as retreatment among 9 previously coiled aneurysms (25.7%). A total occlusion was achieved in 18 aneurysms (51.4%), entry remnant in 3 aneurysms (8.6%), incomplete filling in 6 aneurysms (17.1%) and complete filling in 8 aneurysms (22.9%). None of the aneurysms ruptured during the follow-up period. Of 32 stents deployed, we observed 3 cases (9.4%) of asymptomatic mild stenosis and 3 cases (10.7%) of narrowing of covered branches among 28 covered arteries. There were no cases of perforator infarction and no mortality or permanent morbidity associated with the treatment. Moreover, aneurysms <2.5 mm, aneurysms with a neck <1.8 mm, those with a mean aspect-ratio of 1.4, and lateral wall aneurysms had a higher frequency of adequate occlusion. CONCLUSION Braided stents used as stent monotherapy appear to be sufficiently effective in the treatment of very small intracranial aneurysms, despite a lower overall occlusion rate compared to a standard flow diversion strategy. However, given the low morbidity rate, this strategy may be an alternative to flow-diverter stents for small and distally located lesions.
Collapse
Affiliation(s)
- Carolina Capirossi
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
- Interventional Neuroradiology Unit, University Hospital Careggi, Florence, Italy
| | - Razvan A Radu
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
- Clinical Neurosciences, "Carol Davila" University of Medicine and Pharmacy Bucharest, Bucharest, Romania
| | - Gregory Gascou
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
| | | | - Cyril Dargazanli
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
| | - Paolo Machi
- Neuroradiology Department, University of Geneva, Geneve, Switzerland
| | - Vincent Costalat
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
| | - Federico Cagnazzo
- Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France
| |
Collapse
|
6
|
Zhang J, He L, Xia X, Zhang L, Yu K. Braided stent-assisted coil embolization versus laser engraved stent-assisted coil embolization in patients with unruptured complex intracranial aneurysms. Clinics (Sao Paulo) 2023; 78:100202. [PMID: 37130488 PMCID: PMC10172744 DOI: 10.1016/j.clinsp.2023.100202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 05/04/2023] Open
Abstract
PURPOSES Braided and laser-cut stents both are efficacious and safe for coiling intracranial aneurysms. The study aimed to compare outcomes following braided stent-assisted coil embolization versus laser engraved stent-assisted coil embolization in 266 patients who were diagnosed with unruptured intracranial aneurysms of different types and locations. METHODS Patients with unruptured complex intracranial aneurysms underwent braided (BSE cohort, n = 125) or laser engraved (LSE cohort, n = 141) stent-assisted embolization. RESULTS The deployment success rate was higher for patients of the LSE cohort than those of the BSE cohort (140 [99%] vs. 117 [94%], p = 0.0142). Seventy-one (fifty-seven percentages) and 73 (52%) were coil embolization procedure success rates of the BSE and the LSE cohorts. Periprocedural intracranial hemorrhage was higher in patients of the BSE cohort than those of the LSE cohort (8 [6%] vs. 1 [1%], p = 0.0142). Four (three percentages) patients from the LSE cohort and 3 (2%) patients from the BSE cohort had in-stent thrombosis during embolization. Permanent morbidities were higher in patients of the LSE cohort than those of the BSE cohort (8 [6%] vs. 1 [1%], p = 0.0389). Higher successful procedures (76% vs. 68%) and fewer postprocedural intracranial hemorrhage (0% vs. 5%) and mortality (0% vs. 5%) were reported for patients of the BSE cohort in posterior circulation aneurysmal location than those of the LSE cohort. Laser engraved stent has fewer problems with deployment and may have better periprocedural and follow-up outcomes after embolization. CONCLUSIONS Braided stent-assisted embolization should be preferred when the aneurysm is present in the posterior circulation.
Collapse
Affiliation(s)
- Jie Zhang
- The First Affiliated Hospital of Chengdu Medical College, Department of Neurosurgery, Chengdu, Sichuan, China
| | - Ling He
- The First Affiliated Hospital of Chengdu Medical College, Department of Hematology, Chengdu, Sichuan, China
| | - Xun Xia
- The First Affiliated Hospital of Chengdu Medical College, Department of Neurosurgery, Chengdu, Sichuan, China.
| | - Lie Zhang
- The First Affiliated Hospital of Chengdu Medical College, Department of Neurosurgery, Chengdu, Sichuan, China
| | - Kai Yu
- The First Affiliated Hospital of Chengdu Medical College, Department of Neurosurgery, Chengdu, Sichuan, China
| |
Collapse
|
7
|
Aydin K, Puthuran M, Onal Y, Barburoglu M, Chandran A, Berdikhojayev M, Gravino G, Senturk YE, Aygun S, Velioglu M, Sencer S. The Angiographic and Clinical Follow-up Outcomes of the Wide-Necked and Complex Intracranial Aneurysms Treated With LVIS EVO-Assisted Coiling. Neurosurgery 2023; 92:827-836. [PMID: 36729762 DOI: 10.1227/neu.0000000000002283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Accepted: 09/30/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND The Low Profile Visible Intraluminal Support EVO (LVIS EVO) is a self-expandable braided stent, which was recently introduced for the treatment of intracranial aneurysms. Full visibility of the stent and a relatively high metal coverage ratio are the unique features of the LVIS EVO. OBJECTIVE To assess the safety, efficacy, and midterm durability of LVIS EVO stent-assisted coiling for the treatment of wide-necked intracranial aneurysms. METHODS The endovascular databases were reviewed to identify patients treated with LVIS EVO-assisted coiling. The technical success and immediate clinical/angiographic outcomes were assessed. Periprocedural and delayed complications were evaluated. The follow-up angiographic/clinical outcomes were investigated. The preprocedural/follow-up neurological statuses were assessed with the modified Rankin Scale. RESULTS One hundred three aneurysms in 103 patients (63 females) with a mean age of 54.9 ± 11.3 years were included. The mean maximum sac diameter was 6.2 ± 2.9 mm. The procedural technical success rate was 100%. Immediate postprocedural angiography showed complete occlusion in 77.7%. The mean duration of the angiographic follow-up was 8.8 ± 3.6 months. Follow-up angiography showed complete aneurysm occlusion in 89% of the 82 patients with angiographic follow-up. Recanalization was observed in 7.3% of 82 patients. Two patients (2.4%) required retreatment. In addition, 8.7% of the patients had at least 1 complication, and 2.9% of the patients developed a permanent morbidity. All patients had mRS scores ≤2. CONCLUSION The results of this study demonstrate that SAC with LVIS EVO is a relatively safe, efficient, and durable treatment for wide-necked and complex intracranial aneurysms.
Collapse
Affiliation(s)
- Kubilay Aydin
- Department of Interventional Radiology, Koc University Hospital, Topkapi, Istanbul, Turkey
- Department of Neuroradiology, Istanbul University, Istanbul Faculty of Medicine, Capa, Istanbul, Turkey
| | - Mani Puthuran
- The Walton Centre for Neurology and Neurosurgery, Liverpool, UK
| | - Yilmaz Onal
- Department of Neurosurgery, JSC Central Hospital, Almaty, Kazakhstan
| | - Mehmet Barburoglu
- Department of Neuroradiology, Istanbul University, Istanbul Faculty of Medicine, Capa, Istanbul, Turkey
| | - Arun Chandran
- The Walton Centre for Neurology and Neurosurgery, Liverpool, UK
| | | | - Gilbert Gravino
- The Walton Centre for Neurology and Neurosurgery, Liverpool, UK
| | - Yunus Emre Senturk
- Department of Interventional Radiology, Koc University Hospital, Topkapi, Istanbul, Turkey
| | - Serhat Aygun
- Department of Interventional Radiology, Koc University Hospital, Topkapi, Istanbul, Turkey
| | - Murat Velioglu
- The Walton Centre for Neurology and Neurosurgery, Liverpool, UK
| | - Serra Sencer
- Department of Neuroradiology, Istanbul University, Istanbul Faculty of Medicine, Capa, Istanbul, Turkey
| |
Collapse
|
8
|
Ji Z, Yang W, Ma Y, Bian L, Li G, Fu Y, Piao Y, Zhang H. Case report: Late in-stent thrombosis in a patient with vertebrobasilar dolichoectasia after stent-assisted coil embolization due to the discontinuation of antiplatelet therapy. Front Neurol 2023; 14:1129816. [PMID: 37122309 PMCID: PMC10130566 DOI: 10.3389/fneur.2023.1129816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/20/2023] [Indexed: 05/02/2023] Open
Abstract
Vertebrobasilar dolichoectasia (VBD) is a rare type of cerebrovascular disorder with high rates of morbidity and mortality. Due to the distinct pathological characteristics that fragmented internal elastic lamina and multiple dissections, VBD is difficult to treat and cured. Stent-assisted coil embolization is one of the main treatment modalities for such lesions. However, the duration of healing remained questionable, and there were no effective measures for evaluating endothelial coverage. Before complete endothelial coverage, the discontinuation of antiplatelet therapy may lead to fatal in-stent thrombosis; however, continued antiplatelet therapy could also result in bleeding complications. Thus, we present an autopsy case of late in-stent thrombosis due to the discontinuation of antiplatelet therapy and systematically review the literature to provide a reference for endovascular treatment and antiplatelet regimen of VBD.
Collapse
Affiliation(s)
- Zhe Ji
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Wanxin Yang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Yongjie Ma
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Lisong Bian
- Department of Neurosurgery, Beijing Haidian Hospital, Peking University, Haidian, China
| | - Guilin Li
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Yongjuan Fu
- Department of Pathology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Yueshan Piao
- Department of Pathology, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Hongqi Zhang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
- *Correspondence: Hongqi Zhang
| |
Collapse
|
9
|
Zhang G, Wu Y, Wei Y, Xue G, Chen R, Lv N, Zhang X, Duan G, Yu Y, Li Q, Xu Y, Huang Q, Yang P, Zuo Q, Liu J. Stent-assisted coiling vs. coiling alone of ruptured tiny intracranial aneurysms: A contemporary cohort study in a high-volume center. Front Neurol 2022; 13:1076026. [PMID: 36561296 PMCID: PMC9763558 DOI: 10.3389/fneur.2022.1076026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 11/14/2022] [Indexed: 12/12/2022] Open
Abstract
Objective This study aims to compare the safety and efficacy of stent-assisted coiling (SAC) with those of coiling alone (CA) for the treatment of ruptured tiny intracranial aneurysms. Methods We enrolled 245 patients with ruptured tiny intracranial aneurysms treated with coil embolization. Patients were grouped into SAC and CA groups. Baseline characteristics, periprocedural complications, clinical outcomes, and angiographic results were compared between the two groups. In addition, a subgroup analysis was conducted in the SAC group, and patients were regrouped into low-profile visualized intraluminal support (LVIS) and laser-cut groups to compare the perioperative procedure-related complications and clinical and angiographic follow-up outcomes. Results All baseline characteristics were equivalent between the two groups except for aneurysm size and dome-to-neck aspect ratio. The rates of overall procedure-related complications, intraprocedural rupture, postoperative early rebleeding, intraprocedural thrombosis, postprocedural thrombosis, and procedure-related mortality were comparable between the two groups (P = 0.105, 0.145, 0.308, 1.000, 1.000, 0.160, respectively). Nevertheless, the rate of hemorrhagic complication in the SAC group was significantly higher (P = 0.023). The angiographic follow-up outcomes showed that the SAC group had a higher complete occlusion rate and lower recurrence rate (88.2 vs. 67.1%, 5.4 vs. 15.2%, P = 0.001). The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences (P = 0.192 and P = 0.085, respectively). For subgroup analysis, LVIS stents were associated with a significantly higher rate of complete occlusion (P = 0.014) and a lower rate of intraprocedural rupture (p = 0.021). Moreover, multivariate analysis showed that there were no predictors for the overall, hemorrhagic, and ischemic procedure-related complications, while Raymond class was an independent predictor of retreatment (OR = 3.508, 95% CI 1.168-11.603; P = 0.029). Conclusion Stent-assisted coiling may increase the incidence of hemorrhagic events with favorable angiographic results and comparable clinical outcomes compared with stand-alone coiling. Nevertheless, LVIS stent could improve the safety compared with lazer-cut stent. Simultaneously, considering the better long-term effect, LVIS stent-assisted coiling may be a preferable choice for ruptured tiny intracranial aneurysms.
Collapse
|
10
|
Eker OF, Levrier O, Houdart E, Bonja M, Herbreteau D, Bonafé A, Desal H. Endovascular Treatment of Complex Intracranial Aneurysms With LEO+ Stents: The LEO II Cohort Study. Front Neurol 2022; 13:848683. [PMID: 35837225 PMCID: PMC9275550 DOI: 10.3389/fneur.2022.848683] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 05/31/2022] [Indexed: 11/13/2022] Open
Abstract
IntroductionStent-assisted coiling is an established treatment option for intracranial aneurysms, particularly, wide neck aneurysms with complex anatomy. The purpose of the present study was to assess the safety and efficacy of LEO+ stents in the treatment of intracranial aneurysms.Materials and MethodsA prospective, observational, multicenter study including 12 centers was performed on patients with ruptured, unruptured, and recanalized intracranial aneurysms treated with LEO+ stents. The primary efficacy endpoint was the rate of complete aneurysmal occlusion at 18 months post-procedure, and the primary safety endpoint was the morbidity and mortality at 18 months post-procedure.ResultsFrom March 2015 to June 2017, 176 patients were enrolled (mean age of 54.8 ± 11.5 years; 65.9% women). The aneurysms were located mainly in the anterior communicating artery (29.2%) and the middle cerebral artery (28.6%). They were mostly saccular (94%), with a mean dome size of 5.3 ± 2.6 mm and a mean aspect ratio of 1.2 ± 1.0. In total, 3% of the aneurysms were treated in the acute phase of rupture. Complete/nearly complete aneurysmal occlusion and major recanalization were observed in 89% (n = 146/164) and 1.8% (n = 3/164) of patients at 18-month follow-up, respectively. The LEO+ related mortality rate was 0.6% (n = 1/170), the morbidity rate was 4.1% (n = 7/170), and these patients were mRS 0–2 at 18 months.ConclusionOur results reflecting the use of LEO+ stents in real-world conditions confirm the efficacy and safety of LEO+ stents in the management of complex intracranial aneurysms.
Collapse
Affiliation(s)
- Omer F. Eker
- Department of Neuroradiology, Hôpital Pierre Wertheimer, Hospices Civils de Lyon, Lyon, France
- *Correspondence: Omer F. Eker
| | - Olivier Levrier
- Department of Interventional Neuroradiology, Polyclinique Clairval, Marseille, France
| | - Emmanuel Houdart
- Department of Neuroradiology, Hôpital Lariboisière, Paris, France
| | - Marianne Bonja
- Department of Clinical Affairs, Balt Extrusion, Montmorency, France
| | - Denis Herbreteau
- Department of Radio-Diagnostic and Medical Imaging, Centre Hospitalier Régional et Universitaire Bretonneau, Tours, France
| | - Alain Bonafé
- Department of Neuroradiology, Hôpital Gui-de-Chauliac, Montpellier, France
| | - Hubert Desal
- Department of Diagnostic and Interventional Neuroradiology, Hôpital Guillaume et René Laënnec, Nantes, France
| | | |
Collapse
|
11
|
Tang H, Shang C, Zhang G, Zuo Q, Zhang X, Xu F, Xu Y, Zhao R, Huang Q, Li Q, Liu J. Braided stents assisted coiling for endovascular management of posterior cerebral artery aneurysms: a preliminary mid-term experience. Neuroradiology 2022; 64:1847-1856. [PMID: 35441874 DOI: 10.1007/s00234-022-02956-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 04/10/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Posterior cerebral artery (PCA) aneurysms are rare. This study is to evaluate the preliminary experience of braided stents applied in PCA aneurysms treatment. METHODS Angiographic and clinical data of 28 PCA patients treated with braided stents from July 2016 and September 2020 were retrospectively analyzed. RESULTS A total of 28 PCA aneurysms were enrolled. 22 (78.6%) aneurysms were dissecting aneurysms, while 6 (21.4%) aneurysms were saccular aneurysms. Thirty-five braided stents were implanted with dual stents implanted in 7 cases. Immediate angiographic results show that Raymond class I was obtained in 13 patients (46.4%), Raymond class II was obtained in 4 patients (14.3%), and Raymond class III was obtained in 11 patients (39.3%). Perioperative hemorrhagic events occurred in 1 patient (3.6%). Twenty-four patients (85.7%) received angiographic follow-up, and the mean follow-up time was 11.2 ± 4.9 months. Two patients (8.3%) were confirmed with IA neck recurrence, and 3 patients (12.5%) were confirmed asymptomatic parent artery occlusion (PAO). The other 19 patients were confirmed promoted occlusion with 18 Raymond class I (75%) and 1 Raymond class II (4.2%). Twenty-seven patients (96.4%) received clinical follow-up, and the mean follow-up time was 32.2 ± 13.5 months. One patient (3.7%) confirmed the death event 2 weeks after discharge. The other 27 patients (96.3%) got favorable clinical outcomes with an mRS score of 0-2. CONCLUSIONS Braided stent-assisted coiling with a high occlusion rate and relatively low complication rate provides an alternative strategy in treating PCA aneurysms. Long-term outcomes need further randomized study with larger case numbers.
Collapse
Affiliation(s)
- Haishuang Tang
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China.,Naval Medical Center of PLA, Navy Military Medical University, Shanghai, 200050, People's Republic of China
| | - Chenghao Shang
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Guanghao Zhang
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Qiao Zuo
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Xiaoxi Zhang
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Fengfeng Xu
- Naval Medical Center of PLA, Navy Military Medical University, Shanghai, 200050, People's Republic of China
| | - Yi Xu
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Rui Zhao
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Qinghai Huang
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| | - Qiang Li
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China.
| | - Jianmin Liu
- Department of Neurosurgery, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, People's Republic of China
| |
Collapse
|
12
|
McEachern J, Iancu D, van Adel B, Drake B, Kaderali Z, Spirou M, Lesiuk H, Weill A, Roy D, Raymond J, Hadziomerovic IS, Shankar J. Long term safety and effectiveness of LVIS Jr for treatment of intracranial aneurysms- a Canadian Multicenter registry. Interv Neuroradiol 2022; 29:134-140. [PMID: 35112888 PMCID: PMC10152819 DOI: 10.1177/15910199221077588] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The Low-profile Visible Intraluminal Support device (LVIS Jr) has become a commonly used intracranial stent for the treatment of intracranial aneurysms. However long-term stability and effectiveness remains to be seen. The purpose of the study was to assess the long-term efficacy, safety and durability of LVIS Jr. in a retrospective multicenter registry. METHODS Patients with saccular aneurysms treated at centers across Canada using LVIS Jr for intracranial aneurysms were included in this retrospective registry between the dates of January 2013 and April 2019. Self reported outcomes were collected and used to assess both perioperative and long term safety and effectiveness. Both univariate and multivariate analysis were performed. RESULTS Total of 196 patients (132 Women; mean age of 57.6 years) underwent endovascular aneurysm treatment with at least 1 LVIS Jr. stent. Mean aneurysm dome size was 7.4 mm, and mean neck size of 4.3 mm. Mean clinical and imaging follow up were 950 and 899 days respectively. Class I/II was achieved in 85% on long term follow up. Periprocedural morbidity and mortality was 4.6% and 2% and additional delayed morbidity and mortality was 3% and 2.5%. Aneurysm size >10 mm was independent predictor of periprocedural complication (OR 2.59, p = 0.048) while an increased dome to neck ratio >1.5 was independent predictor of increased delayed complications (OR 3.99, p = 0.02). CONCLUSION The LVIS Jr. intracranial stent is an effective device in the treatment of intracranial aneurysms. Satisfactory long term occlusion rates can be achieved safely with stent-assisted coil embolization.
Collapse
Affiliation(s)
- James McEachern
- Department of Radiology, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada.,Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada.,Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Daniela Iancu
- Department of Radiology, 25443Centre hospitalier de'Universite de Montreal, Montreal, Canada
| | - Brian van Adel
- Division of Neurology, 3710McMaster University, Hamilton, Canada
| | - Brian Drake
- Division of Neurosurgery, University of Ottawa, Ottawa, Canada
| | - Zul Kaderali
- Division of Neurosurgery, University of Manitoba, Winnipeg, Canada
| | - Michael Spirou
- Department of Radiology, 25443Centre hospitalier de'Universite de Montreal, Montreal, Canada
| | - Howard Lesiuk
- Division of Neurosurgery, University of Ottawa, Ottawa, Canada
| | - Alain Weill
- Department of Radiology, 25443Centre hospitalier de'Universite de Montreal, Montreal, Canada
| | - Daniel Roy
- Department of Radiology, 25443Centre hospitalier de'Universite de Montreal, Montreal, Canada
| | - Jean Raymond
- Department of Radiology, 25443Centre hospitalier de'Universite de Montreal, Montreal, Canada
| | | | - Jai Shankar
- Department of Radiology, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada.,Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada.,Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| |
Collapse
|
13
|
Yatomi K, Mitome-Mishima Y, Fujii T, Teranishi K, Oishi H, Kondo A. Outcomes following aneurysmal coil embolization with intentionally shortened low-profile visible intraluminal support stent deployment. Neuroradiol J 2022; 35:77-85. [PMID: 34187225 PMCID: PMC8826284 DOI: 10.1177/19714009211026925] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
PURPOSE Among all stents available for neuroendovascular therapy, the low-profile visible intraluminal support stent bears the highest metal coverage ratio. We deployed a low-profile visible intraluminal support stent with a delivery wire or/and microcatheter system push action to shorten the low-profile visible intraluminal support stent and thus achieve a flow diversion effect. We report our single-institution experience with the use of low-profile visible intraluminal support stents for intentionally shortened deployment (shortening group) and non-shortened deployment (non-shortening group) for unruptured intracranial aneurysms. METHODS We retrospectively reviewed the medical records of 130 patients with 131 intracranial aneurysms who were treated with low-profile visible intraluminal support stent-assisted coil embolization from February 2016-January 2019. All perioperative complications were noted. Every 6 months, we re-examined the patients with cerebral angiography or magnetic resonance angiography. The outcomes of aneurysm occlusion were evaluated by the modified Raymond-Roy occlusion classification. We used the finite element method and computational fluid dynamics to investigate the hemodynamics after shortened low-profile visible intraluminal support stent deployment. RESULTS Immediately after treatment, the modified Raymond-Roy occlusion classification was significantly better in the shortening group than in the non-shortening group (p<0.05). The latest angiographic outcomes showed the same tendency. Hemodynamic analysis by computational fluid dynamics suggested an adequate flow diversion effect with the use of our intentional shortening method. CONCLUSIONS Stent-assisted coil embolization using this technique showed good results of a high complete occlusion rate and low complication rate. These findings suggest that shortened low-profile visible intraluminal support stent deployment yields a flow diversion effect and may lead to early intra-aneurysmal thrombus formation.
Collapse
Affiliation(s)
- Kenji Yatomi
- Department of Neurosurgery, Juntendo
University Faculty of Medicine, Japan,Kenji Yatomi, Department of Neurosurgery, Juntendo
University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
| | - Yumiko Mitome-Mishima
- Department of Neurosurgery, Juntendo
University Faculty of Medicine, Japan,Department of Neurosurgery, National
Defense Medical College, Japan
| | - Takashi Fujii
- Department of Neurosurgery, National
Defense Medical College, Japan,Department of Neuroendovascular Therapy,
Juntendo University Faculty of Medicine, Japan
| | - Kohsuke Teranishi
- Department of Neurosurgery, Juntendo
University Faculty of Medicine, Japan
| | - Hidenori Oishi
- Department of Neurosurgery, Juntendo
University Faculty of Medicine, Japan,Department of Neuroendovascular Therapy,
Juntendo University Faculty of Medicine, Japan
| | - Akihide Kondo
- Department of Neurosurgery, Juntendo
University Faculty of Medicine, Japan
| |
Collapse
|
14
|
Fatania K, Patankar DT. Comprehensive review of the recent advances in devices for endovascular treatment of complex brain aneurysms. Br J Radiol 2022; 95:20210538. [PMID: 34609898 PMCID: PMC8722252 DOI: 10.1259/bjr.20210538] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The International Subarachnoid Aneurysm Trial (ISAT) showed superiority for endovascular treatment of ruptured aneurysms and technology has since moved on rapidly. Many approaches and technology now exist for the endovascular management of ruptured and unruptured intracranial aneurysms, which reflects their varied nature - there is no one-size-fits-all technique. We aim to provide an overview of the various classes of device and the major developments over the past decade. Coiling is the oldest of the technology and continues to demonstrate high levels of occlusion and acceptable risks, making it the default treatment choice, particularly in the acutely ruptured aneurysm setting. Advances on coiling include the use of adjuncts such as balloons, stents and fully retrievable temporary neck-bridging devices, which have facilitated the treatment of more complex aneurysms. Flow divertors have also revolutionised complex aneurysm treatment with small added risk in acute aneurysm treatment and seek to remodel the aneurysm-vessel interface without accessing the aneurysm sac. The latest development and most promising avenue appears to be intrasaccular flow disrupting devices like WEB, Contour and Neqstent that provide excellent opportunities to treat wide neck complex aneurysm with minimal mortality and morbidity and good occlusion rates and may in future replace a significant number of stent-assisted coiling too.
Collapse
Affiliation(s)
- Kavi Fatania
- Radiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | | |
Collapse
|
15
|
Lefevre PH, Schramm P, Kemmling A, Barreau X, Marnat G, Piotin M, Berlis A, Wanke I, Bonafe A, Houdart E. Multi-centric European post-market follow-up study of the Neuroform Atlas Stent System: primary results. J Neurointerv Surg 2021; 14:694-698. [PMID: 34475253 DOI: 10.1136/neurintsurg-2021-017849] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 08/03/2021] [Indexed: 12/28/2022]
Abstract
BACKGROUND Few prospective series have described the safety and effectiveness of the Neuroform Atlas Stent System. We aimed to investigate the efficacy and safety of the device in patients treated for unruptured aneurysm. METHODS ATLAS EU PMCF is a consecutive, prospective, multicentric study that included patients with unruptured saccular aneurysm of all sizes. Follow-up visits were scheduled at 3-6 months and 12-16 months with digital subtraction angiography (DSA) or MRI imaging follow-up as per the site standard of care. The primary efficacy endpoint was adequate aneurysm occlusion (Raymond Roy occlusion grade I and II) on 12 month angiography. The primary safety endpoint was any major stroke or ipsilateral stroke or neurological death within 12 months. RESULTS Of the 106 patients consented, 105 were treated with at least one Neuroform Atlas stent. There was a failed implantation attempt in 1 patient, 85 patients received lateral stenting, and 19 patients received Y-stenting. Mean aneurysm neck size was 4.2 mm (range 1.9-33 mm). Adequate occlusion was observed in 95.1% immediately after the procedure and in 98.9% of cases at 1 year DSA follow-up. Overall, 1.0% (1/102; 95% CI 0.0% to 5.3%) of patients experienced a primary safety endpoint of major stroke. Three minor strokes resulted in a modified Rankin Scale score of 2. CONCLUSIONS In this multicentric, prospective study, stent-assisted coiling of medium size unruptured aneurysms with the Neuroform Atlas stent resulted in a favorable rate of satisfactory occlusion. In our findings, the use of the Y-stenting technique was associated with increased rates of procedural complications. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/ct2/show/NCT02783339.
Collapse
Affiliation(s)
- Pierre-Henri Lefevre
- Neuroradiology department, Gui de Chauliac Hospital Montpellier University Hospital, Montpellier, France
| | - Peter Schramm
- Department of Neuroradiology, University Medical Center Schleswig-Holstein, Luebeck, Germany
| | - André Kemmling
- Institute of Neuroradiology, University Medical Center Schleswig-Holstein, Luebeck, Germany
| | - Xavier Barreau
- Interventional and Diagnostic Neuroradiology, Bordeaux University Hospital, Bordeaux, France
| | - Gaultier Marnat
- Interventional and Diagnostic Neuroradiology, Bordeaux University Hospital, Bordeaux, France
| | - Michel Piotin
- Department of Interventional Neuroradiology, Fondation Rothschild Hospital, Paris, France
| | - Ansgar Berlis
- Department of Diagnostic and Interventional Neuroradiology, Klinikum Augsburg, Augsburg, Bayern, Germany
| | - Isabel Wanke
- Neuroradiology Department, Hirslanden Clinic, Zurich, Switzerland
| | - Alain Bonafe
- Neuroradiology department, Gui de Chauliac Hospital Montpellier University Hospital, Montpellier, France
| | | | | |
Collapse
|
16
|
Zhang L, Chen X, Dong L, Liu P, Jia L, Zhang Y, Lv M. Clinical and Angiographic Outcomes After Stent-Assisted Coiling of Cerebral Aneurysms With Laser-Cut and Braided Stents: A Comparative Analysis of the Literatures. Front Neurol 2021; 12:666481. [PMID: 33995263 PMCID: PMC8116799 DOI: 10.3389/fneur.2021.666481] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/07/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: Stent-assisted coiling (SAC) plays an important role in endovascular treatment of intracranial aneurysms (IAs). This comparative analysis examines the safety and efficacy of SAC in general and compares clinical and angiographic outcomes between laser-cut stents and braided stents. Methods: Relevant English-language studies were identified via a PubMed search for published articles regarding outcomes of SAC using laser-cut stents and braided stents published from 2015 to 2020. Data from 56 studies that met our inclusion criteria were pooled and statistically compared. Results: A total of 4,373 patients harboring with 4,540 IAs were included. Patients were divided into two groups on the basis of stent type: laser-cut stents (2,076 aneurysms in 1991 patients; mean follow-up, 12.99 months) and braided stents (2,464 aneurysms in 2382 patients; mean follow-up, 18.41 months). Overall, the rates of successful stent deployment, thromboembolic events, stent stenosis, periprocedural intracranial hemorrhage, permanent morbidity, mortality, and recanalization were 97.72, 4.72, 2.87, 1.51, 2.14, 1.16, and 6.06%, respectively. Laser-cut stents were associated with a significantly higher rate of successful deployment (p = 0.003) and significantly lower rate of periprocedural intracranial hemorrhage (p = 0.048). Braided stents were associated with a significantly lower rate of permanent morbidity (p = 0.015). Conclusion: SAC of IAs using laser-cut stents or braided stents was effective and safe. Rates of thromboembolic events, stent stenosis, mortality, and recanalization were comparable between the stent types. Braided stents were associated with lower permanent morbidity while laser-cut stents were associated with more favorable rates of successful deployment and periprocedural intracranial hemorrhage.
Collapse
Affiliation(s)
- Longhui Zhang
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Xiheng Chen
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Linggen Dong
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Peng Liu
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Luqiong Jia
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Yisen Zhang
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| | - Ming Lv
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Beijing Tian Tan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
17
|
Monteiro A, Cortez GM, Aghaebrahim A, Sauvageau E, Hanel RA. Low-Profile Visualized Intraluminal Support Jr Braided Stent Versus Atlas Self-Expandable Stent for Treatment of Intracranial Aneurysms: A Single Center Experience. Neurosurgery 2021; 88:E170-E178. [PMID: 33313839 DOI: 10.1093/neuros/nyaa458] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 08/03/2020] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND The Neuroform Atlas Stent and Low-profile Visualized Intraluminal Support (LVIS) and LVIS Jr stents are used to treat intracranial aneurysms (IAs), but their safety, performance, and outcomes have not been directly compared. OBJECTIVE To compare the technical performance and outcomes of Atlas and LVIS Jr stents for treatment of IAs. METHODS IAs treated by stent-assisted coiling using an Atlas (Stryker, Kalamazoo, Michigan) or LVIS Jr (MicroVention, Aliso Viejo, California) device between January 2014 to November 2019 were retrospectively evaluated. Patient demographics, aneurysm size and location, technical difficulties, and clinical and angiographic follow-up were analyzed. RESULTS A total of 116 patients, (mean age 64.2 ± 11.8 yr, 72.7% female) with 121 aneurysms underwent stent-assisted coiling with deployment of Atlas (n = 64) or LVIS Jr (n = 57) stents. Mean aneurysm size was 6.2 ± 2.7 mm. Immediate rates of Raymond-Roy (RR) 1/2 were 89.0% (57/64) and 80.7% (46/57) for the Atlas and LVIS Jr groups, respectively. Neither group had major postoperative thromboembolic complications; however, 15.8% (9/57) of the LVIS Jr procedures had technical issues. Additionally, 88.5% (46/52) and 91.2% (33/36) of patients in the Atlas and LVIS Jr groups had RR 1/2 at a mean follow-up of 13.6 and 18.7 mo, respectively. CONCLUSION Treatment of IAs with Atlas and LVIS Jr stents results in favorable clinical outcomes and angiographic results at follow-up, with low rates of recurrence and retreatment, suggesting both devices are safe and effective. Notably, LVIS Jr had more technical problems than Atlas.
Collapse
Affiliation(s)
- Andre Monteiro
- Baptist Neurological Institute, Lyerly Neurosurgery, Jacksonville, Florida
| | - Gustavo M Cortez
- Baptist Neurological Institute, Lyerly Neurosurgery, Jacksonville, Florida
| | - Amin Aghaebrahim
- Baptist Neurological Institute, Lyerly Neurosurgery, Jacksonville, Florida
| | - Eric Sauvageau
- Baptist Neurological Institute, Lyerly Neurosurgery, Jacksonville, Florida
| | - Ricardo A Hanel
- Baptist Neurological Institute, Lyerly Neurosurgery, Jacksonville, Florida
| |
Collapse
|
18
|
Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents. Chin Neurosurg J 2021; 7:19. [PMID: 33653398 PMCID: PMC7927374 DOI: 10.1186/s41016-021-00237-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 02/06/2021] [Indexed: 11/18/2022] Open
Abstract
Background To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms. Methods Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling (LVIS stent group) and laser-cut stent-assisted coiling (laser-cut stent group) were retrospectively reviewed from January 2014 to December 2017. Propensity score matching was used to adjust for potential differences in age, sex, aneurysm location, aneurysm size, neck width, Hunt-Hess grade, and modified Fisher grade. Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared. Univariate and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk factors. Results A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score matching. The angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group (92.7% vs 80.6%; 3.7% vs 9.7%, P = 0.078). The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences (P = 0.495 and P = 0.875, respectively). The rates of intraprocedural thrombosis, postprocedural thrombosis, postoperative early rebleeding, and procedure-related death were 0.7% (1/142), 1.4% (2/142), 2.8% (4/142), and 2.1% (3/142) in the LVIS stent group, respectively, and 4.3% (4/93), 2.2% (2/93), 1.1% (1/93), and 3.2% (3/93) in the laser-cut stent group, respectively (P = 0.082, 0.649, 0.651, and 0.683). Nevertheless, the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group (5.6% vs 14.0%, P = 0.028; 0.7% vs 6.5%, P = 0.016). Multivariate analysis showed that laser-cut stent-assisted coiling was an independent predictor for overall procedure-related complications (OR = 2.727, P = 0.037); a history of diabetes (OR = 7.275, P = 0.027) and other cerebrovascular diseases (OR = 8.083, P = 0.022) were independent predictors for ischemic complications, whereas none of the factors were predictors for hemorrhagic complications. Conclusions Compared with laser-cut stent-assisted coiling, LVIS stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms could reduce the rates of overall procedure-related complications and intraprocedural rupture.
Collapse
|
19
|
Park H, Nakagawa I, Kotsugi M, Myochin K, Kichikawa K, Nakase H. Traumatic carotid-cavernous fistula treated by trans-arterial stent-assisted coil embolization: Technical note. INTERDISCIPLINARY NEUROSURGERY 2021. [DOI: 10.1016/j.inat.2020.100921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
20
|
Xue G, Liu P, Xu F, Fang Y, Li Q, Hong B, Xu Y, Liu J, Huang Q. Endovascular Treatment of Ruptured Wide-Necked Anterior Communicating Artery Aneurysms Using a Low-Profile Visualized Intraluminal Support (LVIS) Device. Front Neurol 2021; 11:611875. [PMID: 33584512 PMCID: PMC7876256 DOI: 10.3389/fneur.2020.611875] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 12/14/2020] [Indexed: 12/03/2022] Open
Abstract
Objective: To evaluate the safety and efficacy of low-profile visualized intraluminal support (LVIS) stent-assisted coiling for the treatment of ruptured wide-necked anterior communicating artery (ACoA) aneurysms. Methods: The clinical and angiographic data of 31 acutely ruptured wide-necked ACoA aneurysms treated with LVIS stent-assisted coiling between January 2014 and December 2018 were retrospectively reviewed. Results: All stents were successfully deployed. The immediate angiographic results were modified Raymond-Roy class I in 27 cases, modified Raymond-Roy class II in 2 cases, and modified Raymond-Roy class IIIa in 2 cases. Intraoperative thrombosis and postoperative aneurysmal rebleeding occurred in one case each. Two patients (6.5%) who were admitted due to poor clinical grade conditions died during hospital admission as a result of initial bleeding. Angiographic follow-up (mean: 12.9 months) was performed for 26 patients, the results of which demonstrated that 25 aneurysms were completely occluded and one was class II. The last clinical follow-up (mean: 25.3 months) outcomes demonstrated that 27 patients had favorable clinical outcomes and two had poor clinical outcomes. Conclusion: LVIS stent-assisted coiling for ruptured wide-necked ACoA aneurysms was safe and effective, with a relatively low rate of perioperative complications and a high rate of complete occlusion at follow-up.
Collapse
Affiliation(s)
- Gaici Xue
- Department of Neurosurgery, General Hospital of Southern Theatre Command of People's Liberation Army of China, Guangzhou, China
| | - Peng Liu
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Fengfeng Xu
- Department of Neurosurgery, Naval Medical Center of People's Liberation Army of China, Navy Medical University, Shanghai, China
| | - Yibin Fang
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Qiang Li
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Bo Hong
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Yi Xu
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Jianmin Liu
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| | - Qinghai Huang
- Department of Neurosurgery, Changhai Hospital, Navy Medical University, Shanghai, China
| |
Collapse
|
21
|
Mühl-Benninghaus R, Tomori T, Krajewski S, Dietrich P, Simgen A, Yilmaz U, Brochhausen C, Kießling M, Reith W, Cattaneo G. In vivo comparison of braided (Accero) and laser-cut intracranial stents (Acclino, Credo): evaluation of vessel responses at subacute and mid-term follow-up in a rabbit model. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:131. [PMID: 33270156 PMCID: PMC7716819 DOI: 10.1007/s10856-020-06460-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 10/27/2020] [Indexed: 06/12/2023]
Abstract
This study aimed to investigate in vivo two stent technologies, with particular emphasis on thrombogenicity and inflammatory vessel remodeling processes. The micro-stents tested in this study were developed for intracranial aneurysm treatment. In our study twelve, New Zealand white rabbits were divided into two groups: 18 laser-cut stents (LCS) and 18 braided stents (BS) were impanated without admiration of antiplatelet medication. Three stents were implanted into each animal in the common carotid artery, subclavian artery, and abdominal aorta. Digital subtraction angiography was performed before and after stent implantation and at follow-up for the visualization of occurring In-stent thromboembolism or stenosis. The Stents were explanted for histopathological examination at two different timepoints, after 3 and 28 days. Angiographically neither in-stent thrombosis nor stenosis for both groups was seen. There was a progressive increase in the vessel diameter, which was more pronounced for BS than for LCS. We detected a higher number of thrombi adherent to the foreign material on day 3 for BS. On day 3, the neointima was absent, whereas the complete formation observed was on day 28. There was no significant difference between both groups regarding the thickness of the neointima. The in vivo model of our study enabled the evaluation of blood and vessel reactions for two different stent technologies. Differences in vessel dimension and tissue around the stents were observed on day 28. Histological analysis on day 3 enabled the assessment of thrombotic reactions, representing an important complementary result in long-term studies.
Collapse
Affiliation(s)
| | - Toshiki Tomori
- Department of Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany
| | - Stefanie Krajewski
- Department of Thoracic, Cardiac and Vascular Surgery, University Hospital, Tuebingen, Germany
| | - Philipp Dietrich
- Department of Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany
| | - Andreas Simgen
- Department of Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany
| | - Umut Yilmaz
- Department of Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany
| | | | - Mara Kießling
- Department of Pathology, University of Regensburg, Regensburg, Germany
| | - Wolfgang Reith
- Department of Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany
| | - Giorgio Cattaneo
- Institute for Biomedical Engineering, University of Stuttgart, Stuttgart, Germany
| |
Collapse
|
22
|
Safety and Efficacy of the Neuroform Atlas Stent for Treatment of Intracranial Aneurysms : A Systematic Review and Meta-Analysis. Clin Neuroradiol 2020; 31:1167-1180. [PMID: 33252708 DOI: 10.1007/s00062-020-00979-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 11/04/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE The Neuroform Atlas (Stryker Neurovascular, Fremont, CA, USA) is a low-profile laser cut self-expanding nitinol stent designed to provide coil support and wall apposition during aneurysm embolisation. In this study, we performed a meta-analysis of outcomes after treatment with the Neuroform Atlas stent for the purpose of coil embolisation. METHODS The primary objectives of this meta-analysis were to define the safety (treatment-related complications, neurologic outcomes, mortality rate) and the efficacy (aneurysm occlusion rate) of the treatment of intracranial aneurysms with the Neuroform Atlas stent. A systematic review and meta-analysis was performed by searching PubMed, EMBASE, and the Cochrane CENTRAL Library for all published studies on the treatment of intracranial aneurysms with the Neuroform Atlas device up to 6 April 2020. The review was prepared in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. RESULTS A total of 14 studies were analysed (577 patients with 593 intracranial aneurysms). The mean age was 58.2 years and 35.6% were male. Technical success of the procedure was 100%. RROC1/RROC2 (Raymond-Roy occlusion classification (RROC) 1/2) (total occlusion/neck remnant) at a mean follow-up of 8.9 months was achieved in 94.8%. RROC3 was 4.9%. All-cause mortality was 1.8% and permanent residual neurological deficit or disability was 2.7%. Overall complications at follow-up were 6.2%. CONCLUSION Our analysis demonstrated good rates of occlusion at follow-up for aneurysms treated with the Atlas device at follow-up. The safety profile appears similar to other low-profile intracranial stents.
Collapse
|
23
|
Sirakov A, Minkin K, Penkov M, Ninov K, Karakostov V, Sirakov S. Comaneci-Assisted Coiling as a Treatment Option for Acutely Ruptured Wide Neck Cerebral Aneurysm: Case Series of 118 Patients. Neurosurgery 2020; 87:1148-1156. [PMID: 32453823 PMCID: PMC7666901 DOI: 10.1093/neuros/nyaa200] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2019] [Accepted: 03/19/2020] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Wide-necked cerebral aneurysms in the setting of acute subarachnoid hemorrhage (SAH) remain difficult to treat with endovascular methods despite recent progress in the neuroendovascular field. OBJECTIVE To evaluate the effectiveness and safety of the Comaneci device (Rapid Medical, Israel) in endovascular coil embolization of acutely ruptured, wide-necked sidewall, or bifurcation cerebral aneurysms. METHODS We retrospectively reviewed 45 anterior communicating artery, 24 internal carotid artery, 21 middle cerebral artery bifurcation, 15 anterior cerebral artery, and 13 posterior circulation aneurysms, which were treated using Comaneci-assisted coil embolization from August 2017 to January 2019. We evaluated procedural complications, clinical outcomes, and mid-term angiographic follow-up. Immediate and 90 d-clinical outcome and radiological follow-up were obtained in all patients. RESULTS Comaneci-assisted coil embolization was performed in 118 acutely ruptured aneurysms. The technique was carried out successfully in all cases. Simultaneous application of 2 separated Comaneci devices was performed in 8/118 cases (6.77%). Periprocedural thromboembolic complications related to the device were seen in 7/118 cases (5.93%) and severe vasospasm of the parent artery after manipulation of the Comaneci device occurred in 5/118 cases (4.2%). The procedural-related morbidity rate was 2.54%, and there was no procedural related mortality. Among the available survivors, angiographic follow-ups were obtained at 3 and 6 mo, and complete aneurysmal obliteration was confirmed in 81/112 (72.3%) and 75/112 (66.9%) cases, respectively. Mid-term follow-up reviewed total recanalization rate of 14.28%. CONCLUSION Comaneci-assisted embolization of wide-necked intracranial aneurysms in patients presenting with acute SAH is associated with high procedural safety and adequate occlusion rates. Furthermore, dual antiplatelet therapy can be safely avoided in this patient group.
Collapse
Affiliation(s)
| | | | | | | | | | - Stanimir Sirakov
- Correspondence: Stanimir Sirakov, MD, PhD UH St Ivan Rilski, Radiology Department, Bul. Akad. Ivan Geshov 15, Sofia, Bulgaria 1431.
| |
Collapse
|
24
|
Poncyljusz W, Zwarzany Ł, Limanówka B, Zbroszczyk M, Banach M, Bereza S, Sagan L. Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry. J Clin Med 2020; 9:jcm9103168. [PMID: 33007864 PMCID: PMC7601776 DOI: 10.3390/jcm9103168] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 09/20/2020] [Accepted: 09/29/2020] [Indexed: 11/16/2022] Open
Abstract
Purpose: The low-profile visualized intraluminal support junior (LVIS Jr.) is a new generation low-profile braided stent. Our aim was to evaluate the safety and efficacy of the LVIS Jr. in the stent-assisted coiling of unruptured middle cerebral artery (MCA) aneurysms. This was a multicenter retrospective study. Patient demographics, aneurysm characteristics, procedural details, complications, and the results of clinical and imaging follow-up were analyzed. Four centers participated in the study. A total of 162 consecutive patients with 162 unruptured MCA aneurysms were included for the analysis. The mean aneurysm size was 7.6 mm (range 2 to 37 mm) and 97.5% were wide-necked. Immediate postprocedural angiograms showed Raymond-Roy class 1 in 118 (72.8%), class 2 in 23 (14.2%), and class 3 in 21 patients (13%). Periprocedural complications occurred in 14 patients (8.6%). There were no procedure-related deaths. Follow-up imaging at 12–18 months post-procedure showed Raymond–Roy class 1 in 132 (81.5%), class 2 in 17 (10.5%), and class 3 in 13 patients (8%). There were 3 cases of in-stent stenosis (1.9%). All 162 patients had good clinical outcome (mRS score 0–2) at 90 days post-procedure. Stent-assisted coiling of unruptured MCA aneurysms with the LVIS Jr. stent is safe and effective, with high immediate and long-term total occlusion rates.
Collapse
Affiliation(s)
- Wojciech Poncyljusz
- Department of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, Unii Lubelskiej 1, 71-252 Szczecin, Poland;
| | - Łukasz Zwarzany
- Department of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, Unii Lubelskiej 1, 71-252 Szczecin, Poland;
- Correspondence:
| | - Bartosz Limanówka
- Department of Neurosurgery and Pediatric Neurosurgery, Pomeranian Medical University, Unii Lubelskiej 1, 71-252 Szczecin, Poland; (B.L.); (L.S.)
| | - Miłosz Zbroszczyk
- Department of Radiodiagnostic and Interventional Radiology, Silesian Medical University, Medyków 14, 40-772 Katowice, Poland;
| | - Mariusz Banach
- Department of Neurosurgery, Saint Raphael Hospital, Adama Bochenka 12, 30-693 Kraków, Poland;
| | - Sławomir Bereza
- Neurointerventional CathLab, Lower Silesian Specialist Tadeusz Marciniak Memorial Hospital—Emergency Medicine Center, Fieldorfa 2, 54-049 Wrocław, Poland;
| | - Leszek Sagan
- Department of Neurosurgery and Pediatric Neurosurgery, Pomeranian Medical University, Unii Lubelskiej 1, 71-252 Szczecin, Poland; (B.L.); (L.S.)
| |
Collapse
|
25
|
Nania A, Dobbs N, DuPlessis J, Keston P, Downer J. Early experience treating intracranial aneurysms using Accero: a novel, fully visible, low profile braided stent with platinum-nitinol composite wire technology. J Neurointerv Surg 2020; 13:49-53. [PMID: 32522786 DOI: 10.1136/neurintsurg-2020-015918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 05/12/2020] [Accepted: 05/12/2020] [Indexed: 11/04/2022]
Abstract
BACKGROUND Accero is an innovative, fully visible, self-expanding braided stent with platinum-nitinol composite wire technology, produced by Acandis. OBJECTIVE To assess the technical success and safety of this new stent by evaluating the intraprocedural behavior and complication rate, and the short-term follow-up results. METHODS Forty-one consecutive patients suitable for stent-assisted coiling were selected for the use of Accero in an 11-month period. Clinical, procedural, and angiographic data, as well as 30-day morbidity, were recorded. The angiographic results, clinical follow-up at 30 days, and early imaging follow-up at 3 or 6 months were analyzed, when available. RESULTS Forty-one aneurysms were treated with stent-assisted coiling. All cases were elective, of which 19 were previously untreated aneurysms and 22 were recurrent aneurysms. Aneurysm location was anterior communicating artery complex (16), basilar (12 cases), middle cerebral artery bifurcation (9 cases), and internal cerebral artery (4 cases). The stent was successfully deployed and aneurysm occlusion with coils achieved in 100% of our patients. One case of on table in-stent thrombosis occurred, which resolved after administration of glycoprotein IIB/IIIA inhibitor, with no clinical consequence, and one case of postoperative hematoma at the arteriotomy site, which was managed conservatively. On early follow-up, available for 37 patients, the complete occlusion rate was 76%, with only two recurrences needing further treatment. Satisfactory aneurysm occlusion was therefore achieved in 95% of cases. CONCLUSION Stent-assisted coiling with the Accero braided stent proved safe and effective.
Collapse
Affiliation(s)
- Alberto Nania
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - Nicholas Dobbs
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - Johannes DuPlessis
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - Peter Keston
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - Jonathan Downer
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| |
Collapse
|
26
|
Ciochon UM, Steuble Brandt EG, Stavngaard T. Acute Tentorial Subdural Hematoma Caused by Rupture of the Posterior Cerebral Artery after Minor Trauma-A Case Report. Diagnostics (Basel) 2020; 10:diagnostics10030175. [PMID: 32210036 PMCID: PMC7151171 DOI: 10.3390/diagnostics10030175] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 03/18/2020] [Accepted: 03/20/2020] [Indexed: 12/02/2022] Open
Abstract
Acute subdural hematoma (aSDH) is a common pathology encountered after head trauma. Only a minority of aSDHs have an arterial source. In this article, we report a case of aSDH originating from a traumatic pseudoaneurysm of the distal segment of posterior cerebral artery (PCA), diagnosed several days after the initial minor trauma and successfully treated with endovascular coiling. This case emphasizes the importance of searching for vascular pathology when the localization, severity or relapsing course of the intracranial hemorrhage does not fully correspond to the severity of initial trauma and when the bleeding has a delayed onset. Characteristics, diagnostics and treatment possibilities of traumatic cerebral aneurysms, an important cause of arterial aSDH, are described in the article.
Collapse
Affiliation(s)
- Urszula Maria Ciochon
- Department of Diagnostic Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; (E.G.S.B.); (T.S.)
- Correspondence:
| | - Erik Gudmann Steuble Brandt
- Department of Diagnostic Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; (E.G.S.B.); (T.S.)
- Department of Radiology, Holbæk Hospital, Smedelundsgade 60, 4300 Holbæk, Denmark
| | - Trine Stavngaard
- Department of Diagnostic Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; (E.G.S.B.); (T.S.)
| |
Collapse
|
27
|
Lv X, Jiang C, Liang S. Small ruptured and unruptured complex cerebral aneurysms: Single center experience of low-profile visualized intraluminal support stent. JOURNAL OF NEURORESTORATOLOGY 2019. [DOI: 10.26599/jnr.2019.9040025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Objectives: Even though low-profile visualized intraluminal support (LVIS) device is used extensively currently and provide intraluminal support in complex cerebral aneurysm embolization, only few studies have reported its clinical results. This study presents the results of patients treated with LVIS. Patients and methods: Cerebral aneurysms with an undefined neck, fusiform shape, and blood blister-like aneurysms that were treated with LVIS between May 2017 and May 2019 were reviewed retrospectively. Results: Overall, 112 aneurysms in 104 patients were treated using LVIS, and 105 LVISs were placed. Of these, 101 aneurysms (90%) were small (< 10 mm) in size, 17 were fusiform aneurysms, and 3 were blood blister-like aneurysms. Overall, 39 patients suffered a subarachnoid hemorrhage and 65 had no bleeding history. 2 patients died of internal carotid artery (ICA) thrombosis, resulting in 1.9% mortality rate. Follow-up angiography was obtained in 68 patients (65%), and the complete obliteration rate was 98.5% in 6–12 months. Conclusion: The LVIS is a safe and effective treatment for small ruptured or unruptured complex intracranial aneurysms.
Collapse
|