1
|
Link JS, O'Donnell-Sloan J, Curdts S, Geiss BJ, Dandy DS, Henry CS. Multiplexed Capillary-Flow Driven Immunoassay for Respiratory Illnesses. Anal Chem 2024; 96:4111-4119. [PMID: 38417100 DOI: 10.1021/acs.analchem.3c04977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
Multiplexed analysis in medical diagnostics is widely accepted as a more thorough and complete method compared to single-analyte detection. While analytical methods like polymerase chain reaction and enzyme-linked immunosorbent assay (ELISA) exist for multiplexed detection of biomarkers, they remain time-consuming and expensive. Lateral flow assays (LFAs) are an attractive option for point-of-care testing, and examples of multiplexed LFAs exist. However, these devices are limited by spatial resolution of test lines, large sample volume requirements, cross-reactivity, and poor sensitivity. Recent work has developed capillary-flow microfluidic ELISA platforms as a more sensitive alternative to LFAs; however, multiplexed detection on these types of devices has yet to be demonstrated. In the aftermath of the initial SARS-CoV-2 pandemic, the need for rapid, sensitive point-of-care devices has become ever clearer. Moving forward, devices that can distinguish between diseases with similar presenting symptoms would be the ideal home diagnostic. Here, the first example of a multiplexed capillary-flow immunoassay device for the simultaneous detection of multiple biomarkers is reported. From a single sample addition step, the reagents and washing steps required for two simultaneous ELISAs are delivered to spatially separated test strips. Visual results can be obtained in <15 min, and images captured with a smartphone can be analyzed for quantitative data. This device was used to distinguish between and quantify H1N1 hemagglutinin (HA) and SARS-CoV-2 nucleocapsid protein (N-protein). Using this device, analytical detection limits of 840 and 133 pg/mL were obtained for hemagglutinin and nucleocapsid protein, respectively. The presence of one target in the device did not increase the signal on the other test line, indicating no cross-reactivity between the assays. Additionally, simultaneous detection of both N-protein and HA was performed as well as simultaneous detection of N-protein and human C-reactive protein (CRP). Elevated levels of CRP in a patient infected with SARS-CoV-2 have been shown to correlate with more severe outcomes and a greater risk of death as well. To further expand on the simultaneous detection of two biomarkers, CRP and N-protein were detected simultaneously, and the presence of SARS-CoV-2 N-protein did not interfere with the detection of CRP when both targets were present in the sample.
Collapse
Affiliation(s)
- Jeremy S Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - John O'Donnell-Sloan
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
| | - Sierra Curdts
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Brian J Geiss
- Department of Microbiology, Immunology and Pathology, Colorado State University, Fort Collins, Colorado 80523, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - David S Dandy
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- Metalluragy and Materials Research Institute, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
2
|
Soares JC, Soares AC, Angelim MKSC, Proença-Modena JL, Moraes-Vieira PM, Mattoso LHC, Oliveira ON. Diagnostics of SARS-CoV-2 infection using electrical impedance spectroscopy with an immunosensor to detect the spike protein. Talanta 2021; 239:123076. [PMID: 34876273 PMCID: PMC8607795 DOI: 10.1016/j.talanta.2021.123076] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 11/09/2021] [Accepted: 11/16/2021] [Indexed: 11/04/2022]
Abstract
Mass testing for the diagnostics of COVID-19 has been hampered in many countries owing to the high cost of the methodologies to detect genetic material of SARS-CoV-2. In this paper, we report on a low-cost immunosensor capable of detecting the spike protein of SARS-CoV-2, including in samples of inactivated virus. Detection is performed with electrical impedance spectroscopy using an immunosensor that contains a monolayer film of carboxymethyl chitosan as matrix, coated with an active layer of antibodies specific to the spike protein. In addition to a low limit of detection of 0.179 fg/mL within an almost linear behavior from 10−20 g/mL to 10−14 g/mL, the immunosensor was highly selective. For the samples with the spike protein could be distinguished in multidimensional projection plots from samples with other biomarkers and analytes that could be interfering species for healthy and infected patients. The excellent analytical performance of the immunosensors was validated with the distinction between control samples and those containing inactivated SARS-CoV-2 at different concentrations. The mechanism behind the immunosensor performance is the specific antibody-protein interaction, as confirmed with the changes induced in C–H stretching and protein bands in polarization-modulated infrared reflection absorption spectra (PM-IRRAS). Because impedance spectroscopy measurements can be made with low-cost portable instruments, the immunosensor proposed here can be applied in point-of-care diagnostics for mass testing even in places with limited resources.
Collapse
Affiliation(s)
- Juliana C Soares
- São Carlos Institute of Physics (IFSC), University of São Paulo (USP), 13566-590, São Carlos, Brazil
| | - Andrey C Soares
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil
| | - Monara Kaelle S C Angelim
- Department of Genetics, Evolution, Microbiology and Immunology, Institute of Biology, University of Campinas, 13083-862, Campinas, SP, Brazil
| | - Jose Luiz Proença-Modena
- Department of Genetics, Evolution, Microbiology and Immunology, Institute of Biology, University of Campinas, 13083-862, Campinas, SP, Brazil; Experimental Medicine Research Cluster (EMRC), University of Campinas, 13083-862, Campinas, SP, Brazil
| | - Pedro M Moraes-Vieira
- Department of Genetics, Evolution, Microbiology and Immunology, Institute of Biology, University of Campinas, 13083-862, Campinas, SP, Brazil; Experimental Medicine Research Cluster (EMRC), University of Campinas, 13083-862, Campinas, SP, Brazil; Obesity and Comorbilities Research Center (OCRC), University of Campinas, 13083-862, Campinas, SP, Brazil
| | - Luiz H C Mattoso
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics (IFSC), University of São Paulo (USP), 13566-590, São Carlos, Brazil.
| |
Collapse
|
3
|
Yoo HM, Kim IH, Kim S. Nucleic Acid Testing of SARS-CoV-2. Int J Mol Sci 2021; 22:6150. [PMID: 34200331 PMCID: PMC8201071 DOI: 10.3390/ijms22116150] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 05/25/2021] [Accepted: 06/04/2021] [Indexed: 12/13/2022] Open
Abstract
The coronavirus disease 2019 (COVID-19) has caused a large global outbreak. It is accordingly important to develop accurate and rapid diagnostic methods. The polymerase chain reaction (PCR)-based method including reverse transcription-polymerase chain reaction (RT-PCR) is the most widely used assay for the detection of SARS-CoV-2 RNA. Along with the RT-PCR method, digital PCR has emerged as a powerful tool to quantify nucleic acid of the virus with high accuracy and sensitivity. Non-PCR based techniques such as reverse transcription loop-mediated isothermal amplification (RT-LAMP) and reverse transcription recombinase polymerase amplification (RT-RPA) are considered to be rapid and simple nucleic acid detection methods and were reviewed in this paper. Non-conventional molecular diagnostic methods including next-generation sequencing (NGS), CRISPR-based assays and nanotechnology are improving the accuracy and sensitivity of COVID-19 diagnosis. In this review, we also focus on standardization of SARS-CoV-2 nucleic acid testing and the activity of the National Metrology Institutes (NMIs) and highlight resources such as reference materials (RM) that provide the values of specified properties. Finally, we summarize the useful resources for convenient COVID-19 molecular diagnostics.
Collapse
Affiliation(s)
- Hee Min Yoo
- Microbiological Analysis Team, Biometrology Group, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea; (H.M.Y.); (I.-H.K.)
- Department of Bio-Analytical Science, University of Science & Technology (UST), Daejeon 34113, Korea
| | - Il-Hwan Kim
- Microbiological Analysis Team, Biometrology Group, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea; (H.M.Y.); (I.-H.K.)
| | - Seil Kim
- Microbiological Analysis Team, Biometrology Group, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea; (H.M.Y.); (I.-H.K.)
- Department of Bio-Analytical Science, University of Science & Technology (UST), Daejeon 34113, Korea
- Convergent Research Center for Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon 34114, Korea
| |
Collapse
|
4
|
Sixto‐López Y, Martínez‐Archundia M. Drug repositioning to target NSP15 protein on SARS-CoV-2 as possible COVID-19 treatment. J Comput Chem 2021; 42:897-907. [PMID: 33713492 PMCID: PMC8250597 DOI: 10.1002/jcc.26512] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 02/04/2021] [Accepted: 02/21/2021] [Indexed: 01/15/2023]
Abstract
SARS-CoV and SARS-CoV-2 belong to the subfamily Coronaviridae and infect humans, they are constituted by four structural proteins: Spike glycoprotein (S), membrane (M), envelope (E) and nucleocapsid (N), and nonstructural proteins, such as Nsp15 protein which is exclusively present on nidoviruses and is absent in other RNA viruses, making it an ideal target in the field of drug design. A virtual screening strategy to search for potential drugs was proposed, using molecular docking to explore a library of approved drugs available in the DrugBank database in order to identify possible NSP15 inhibitors to treat Covid19 disease. We found from the docking analysis that the antiviral drugs: Paritaprevir and Elbasvir, currently both approved for hepatitis C treatment which showed some of the lowest free binding energy values were considered as repositioning drugs to combat SARS-CoV-2. Furthermore, molecular dynamics simulations of the Apo and Holo-Nsp15 systems were performed in order to get insights about the stability of these protein-ligand complexes.
Collapse
Affiliation(s)
- Yudibeth Sixto‐López
- Laboratorio de Diseño y Desarrollo de Nuevos Fármacos e Innovación Biotecnológica (Laboratory for the Design and Development of New Drugs and Biotechnological Innovation), Sección de Estudios de Posgrado e InvestigaciónEscuela Superior de Medicina, Instituto Politécnico Nacional, Plan de San Luis y Salvador Díaz Mirón s/n, Casco de Santo TomásCiudad de MéxicoMexico
| | - Marlet Martínez‐Archundia
- Laboratorio de Diseño y Desarrollo de Nuevos Fármacos e Innovación Biotecnológica (Laboratory for the Design and Development of New Drugs and Biotechnological Innovation), Sección de Estudios de Posgrado e InvestigaciónEscuela Superior de Medicina, Instituto Politécnico Nacional, Plan de San Luis y Salvador Díaz Mirón s/n, Casco de Santo TomásCiudad de MéxicoMexico
| |
Collapse
|
5
|
Sawicki R, Korona-Glowniak I, Boguszewska A, Stec A, Polz-Dacewicz M. Sample pooling as a strategy for community monitoring for SARS-CoV-2. Sci Rep 2021; 11:3122. [PMID: 33542424 PMCID: PMC7862381 DOI: 10.1038/s41598-021-82765-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 01/20/2021] [Indexed: 01/01/2023] Open
Abstract
Sample pooling strategy was intended to determine the optimal parameters for group testing of pooled specimens for the detection of SARS-CoV-2 and process them without significant loss of test usability. Standard molecular diagnostic laboratory equipment, and commercially available centrifugal filters, RNA isolation kits and SARS Cov2 PCR tests were used. The basic idea was to combine and concentrate several samples to the maximal volume, which can be extracted with the single extraction column. Out of 16 tested pools, 12 were positive with cycle threshold (Ct) values within 0.5 and 3.01 Ct of the original individual specimens. The analysis of 112 specimens determined that 12 pools were positive, followed by identification of 6 positive individual specimens among the 112 tested. This testing was accomplished with the use of 16 extractions/PCR tests, resulting in saving of 96 reactions but adding the 40 centrifugal filters. The present study demonstrated that pool testing could detect even up to a single positive sample with Ct value as high as 34. According to the standard protocols, reagents and equipment, this pooling method can be applied easily in current clinical testing laboratories.
Collapse
Affiliation(s)
- Rafal Sawicki
- Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20093, Lublin, Poland.
| | - Izabela Korona-Glowniak
- Department of Pharmaceutical Microbiology, Medical University of Lublin, 20-093, Lublin, Poland
| | - Anastazja Boguszewska
- Department of Virology with SARS Laboratory, Medical University of Lublin, Lublin, Poland
| | - Agnieszka Stec
- Department of Medical Microbiology, Medical University of Lublin, 20-093, Lublin, Poland
| | | |
Collapse
|
6
|
Yan Y, Chang L, Wang L. Laboratory testing of SARS-CoV, MERS-CoV, and SARS-CoV-2 (2019-nCoV): Current status, challenges, and countermeasures. Rev Med Virol 2020; 30:e2106. [PMID: 32302058 PMCID: PMC7235496 DOI: 10.1002/rmv.2106] [Citation(s) in RCA: 188] [Impact Index Per Article: 47.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 03/20/2020] [Accepted: 03/20/2020] [Indexed: 01/08/2023]
Abstract
Emerging and reemerging infectious diseases are global public concerns. With the outbreak of unknown pneumonia in Wuhan, China in December 2019, a new coronavirus, SARS-CoV-2 has been attracting tremendous attention. Rapid and accurate laboratory testing of SARS-CoV-2 is essential for early discovery, early reporting, early quarantine, early treatment, and cutting off epidemic transmission. The genome structure, transmission, and pathogenesis of SARS-CoV-2 are basically similar to SARS-CoV and MERS-CoV, the other two beta-CoVs of medical importance. During the SARS-CoV and MERS-CoV epidemics, a variety of molecular and serological diagnostic assays were established and should be referred to for SARS-CoV-2. In this review, by summarizing the articles and guidelines about specimen collection, nucleic acid tests (NAT) and serological tests for SARS-CoV, MERS-CoV, and SARS-CoV-2, several suggestions are put forward to improve the laboratory testing of SARS-CoV-2. In summary, for NAT: collecting stool and blood samples at later periods of illness to improve the positive rate if lower respiratory tract specimens are unavailable; increasing template volume to raise the sensitivity of detection; putting samples in reagents containing guanidine salt to inactivate virus as well as protect RNA; setting proper positive, negative and inhibition controls to ensure high-quality results; simultaneously amplifying human RNase P gene to avoid false-negative results. For antibody test, diverse assays targeting different antigens, and collecting paired samples are needed.
Collapse
Affiliation(s)
- Ying Yan
- National Center for Clinical Laboratories, Beijing Hospital, National Center of GerontologyInstitute of Geriatric Medicine, Chinese Academy of Medical SciencesBeijingChina
- Beijing Engineering Research Center of Laboratory MedicineBeijing HospitalBeijingChina
| | - Le Chang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of GerontologyInstitute of Geriatric Medicine, Chinese Academy of Medical SciencesBeijingChina
- Beijing Engineering Research Center of Laboratory MedicineBeijing HospitalBeijingChina
| | - Lunan Wang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of GerontologyInstitute of Geriatric Medicine, Chinese Academy of Medical SciencesBeijingChina
- Beijing Engineering Research Center of Laboratory MedicineBeijing HospitalBeijingChina
- Graduate School, Peking Union Medical CollegeChinese Academy of Medical SciencesBeijingChina
| |
Collapse
|
7
|
Ieven M. Currently used nucleic acid amplification tests for the detection of viruses and atypicals in acute respiratory infections. J Clin Virol 2007; 40:259-76. [PMID: 17977063 PMCID: PMC7108459 DOI: 10.1016/j.jcv.2007.08.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2007] [Accepted: 08/20/2007] [Indexed: 12/03/2022]
Abstract
For the detection of respiratory viruses conventional culture techniques are still considered as the gold standard. However, results are mostly available too late to have an impact on patient management. The latest developments include appropriate DNA- and RNA-based amplification techniques (both NASBA and PCR) for the detection of an extended number of agents responsible for LRTI. Real time amplification, the latest technical progress, produces, within a considerable shorter time, results with a lower risk of false positives. As results can be obtained within the same day, patient management with appropriate therapy or reduction of unnecessary antibiotic therapy in LRTI will be possible. A number of technical aspects of these amplification assays, and their advantages are discussed. The availability and use of these new diagnostic tools in virology has contributed to a better understanding of the role of respiratory viruses in LRTI. The increasing importance of the viral agents, Mycoplasma pneumoniae and Chlamydophila pneumoniae in ARI is illustrated. A great proportion of ARI are caused by viruses, but their relative importance depends on the spectrum of agents covered by the diagnostic techniques and on the populations studied, the geographical location and the season. The discovery of new viruses is ongoing; examples are the hMPV and the increasing number of coronaviruses. Indications for the use of these rapid techniques in different clinical situations are discussed. Depending on the possibilities, the laboratory could optimize its diagnostic strategy by applying a combination of immunofluorescence for the detection of RSV an IFL, and a combination of real-time amplification tests for other respiratory viruses and the atypical agents. When implementing a strategy, a compromise between sensitivity, clinical utility, turn around time and cost will have to be found.
Collapse
Affiliation(s)
- Margareta Ieven
- Laboratory for Microbiology, Vaccine & Infectious Disease Institute (VIDI), University Hospital Antwerp, University of Antwerp, Wilrijkstraat 10, B-2650 Edegem, Belgium.
| |
Collapse
|
8
|
Escutenaire S, Mohamed N, Isaksson M, Thorén P, Klingeborn B, Belák S, Berg M, Blomberg J. SYBR Green real-time reverse transcription-polymerase chain reaction assay for the generic detection of coronaviruses. Arch Virol 2006; 152:41-58. [PMID: 16941059 PMCID: PMC7087200 DOI: 10.1007/s00705-006-0840-x] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2006] [Accepted: 07/12/2006] [Indexed: 12/02/2022]
Abstract
Coronaviruses are etiologic agents of respiratory and enteric diseases in humans and in animals. In this study, a one-step real-time reverse transcription-polymerase chain reaction (RT-PCR) assay based on SYBR Green chemistry and degenerate primers was developed for the generic detection of coronaviruses. The primers, designed in the open reading frame 1b, enabled the detection of 32 animal coronaviruses including strains of canine coronavirus, feline coronavirus, transmissible gastroenteritis virus (TGEV), bovine coronavirus (BCoV), murine hepatitis virus (MHV) and infectious bronchitis virus (IBV). A specific amplification was also observed with the human coronaviruses (HCoV) HCoV-NL63, HCoV-OC43, HCoV-229E and severe acute respiratory syndrome coronavirus (SARS-CoV). The real-time RT-PCR detected down to 10 cRNA copies from TGEV, BCoV, SARS-CoV and IBV. In addition, the assay exhibited a high sensitivity and specificity on clinical samples from different animal species. The developed assay represents a potential tool for laboratory diagnostics and for detecting still uncharacterized coronaviruses.
Collapse
Affiliation(s)
- S Escutenaire
- Department of Virology, National Veterinary Institute, Uppsala, Sweden
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Yip SP, To SST, Leung PHM, Cheung TS, Cheng PKC, Lim WWL. Use of dual TaqMan probes to increase the sensitivity of 1-step quantitative reverse transcription-PCR: application to the detection of SARS coronavirus. Clin Chem 2006; 51:1885-8. [PMID: 16189379 PMCID: PMC7108148 DOI: 10.1373/clinchem.2005.054106] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Shea Ping Yip
- Department of Health Technology & Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China.
| | | | | | | | | | | |
Collapse
|
10
|
Sampath R, Hofstadler SA, Blyn LB, Eshoo MW, Hall TA, Massire C, Levene HM, Hannis JC, Harrell PM, Neuman B, Buchmeier MJ, Jiang Y, Ranken R, Drader JJ, Samant V, Griffey RH, McNeil JA, Crooke ST, Ecker DJ. Rapid identification of emerging pathogens: coronavirus. Emerg Infect Dis 2005; 11:373-9. [PMID: 15757550 PMCID: PMC3298233 DOI: 10.3201/eid1103.040629] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
New surveillance approach can analyze >900 polymerase chain reactions per day. We describe a new approach for infectious disease surveillance that facilitates rapid identification of known and emerging pathogens. The process uses broad-range polymerase chain reaction (PCR) to amplify nucleic acid targets from large groupings of organisms, electrospray ionization mass spectrometry for accurate mass measurements of PCR products, and base composition signature analysis to identify organisms in a sample. We demonstrate this principle by using 14 isolates of 9 diverse Coronavirus spp., including the severe acute respiratory syndrome–associated coronavirus (SARS-CoV). We show that this method could identify and distinguish between SARS and other known CoV, including the human CoV 229E and OC43, individually and in a mixture of all 3 human viruses. The sensitivity of detection, measured by using titered SARS-CoV spiked into human serum, was ≈1 PFU/mL. This approach, applicable to the surveillance of bacterial, viral, fungal, or protozoal pathogens, is capable of automated analysis of >900 PCR reactions per day.
Collapse
|