1
|
Spiesecke P, Thiemann J, Conen P, Clevert DA. Contrast enhanced ultrasound of cystic renal lesions, from diagnosis up to treatment. Clin Hemorheol Microcirc 2024:CH248102. [PMID: 39365320 DOI: 10.3233/ch-248102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/05/2024]
Abstract
Ultrasound is the most used interdisciplinary imaging technique in clinical routine for assessment of renal pathologies. This includes the monitoring of cystic renal lesions, which can be classified as non-complicated or complicated and by means of occurrence as solitary or multifocal lesions. The Bosniak-classification (I-IV) classifies renal cysts in 5 different categories and is used for decisions of further clinical treatment. This classification was developed for computed tomography and has been adopted for magnetic resonance imaging as well as contrast-enhanced ultrasound. In the following review article, cystic kidney lesions and their differentiation using contrast-enhanced ultrasound are presented and an overview of the therapy options is given. In interventional procedures, CEUS can make a valuable contribution in histological sampling, reduce radiation exposure and, under certain circumstances, the number of interventions for the patient.
Collapse
Affiliation(s)
- P Spiesecke
- Department of Radiology, Interdisciplinary Ultrasound Center, Campus Charité Mitte, Charité, Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - J Thiemann
- Department of Radiology, Ludwig-Maximilians-University Munich, Germany
| | - P Conen
- Department of Radiology, Ludwig-Maximilians-University Munich, Germany
| | - D-A Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich, Germany
- Interdisciplinary Ultrasound-Center, Ludwig-Maximilians-University Munich, Germany
| |
Collapse
|
2
|
Zhang WB, Deng WF, He BL, Wei YY, Liu Y, Chen Z, Xu RY. Diagnostic value of CEUS combined with C-TIRADS for indeterminate FNA cytological thyroid nodules. Clin Hemorheol Microcirc 2024:CH242363. [PMID: 39213055 DOI: 10.3233/ch-242363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
OBJECTIVES To investigate the diagnostic value of CEUS combined with C-TIRADS for indeterminate FNA cytological thyroid nodules. METHODS The clinical data, ultrasonic images, C-TIRADS categories and CEUS images of 192 patients with indeterminate FNA cytological thyroid nodules confirmed by the surgical pathology were analyzed retrospectively. The diagnostic efficacy of CEUS, C-TIRADS and CEUS-TIRADS were calculated. RESULTS The AUCs of CEUS, C-TIRADS and CEUS-TIRADS were 0.905 (95% CI: 0.862∼0.949), 0.881 (95% CI: 0.825∼0.938) and 0.954 (95% CI: 0.922∼0.986), respectively. The sensitivity, specificity, PPV, NPV, accuracy, LR- and LR+ were 84.7% (116/137), 85.5% (47/55), 93.5% (116/124), 69.1% (47/68), 84.9% (163/192), 0.179, 5.82 and 84.7% (116/137), 83.6% (46/55), 92.8% (116/125), 68.7% (46/67), 84.4% (162/192), 0.183, 5.17, 92.7% (127/137), 89.1% (49/55), 95.5% (127/133), 83.1% (49/59), 91.7% (176/192), 0.082, and 8.50, respectively. Compared with CEUS and C-TIRADS, CEUS-TIRADS had improved the AUC, sensitivity and accuracy (all P < 0.05). CONCLUSIONS CEUS and C-TIRADS had high diagnostic values in indeterminate FNA cytological thyroid nodules. CEUS-TIRADS improved AUC, diagnostic sensitivity and accuracy, and helped to distinguish indeterminate FNA cytological nodules.
Collapse
Affiliation(s)
- Wei-Bing Zhang
- Department of Medical Ultrasound, Jiangsu Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Wen-Fang Deng
- Department of General Medical, Northern Jiangsu People's Hospital of Jiangsu Province, Yangzhou, China
| | - Bei-Li He
- Department of Medical Ultrasound, Jiangsu Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Ying-Ying Wei
- Department of Medical Ultrasound, Jiangsu Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Yu Liu
- Department of Medical Ultrasound, Jiangsu Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Zhe Chen
- Department of Medical Ultrasound, Jiangsu Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Ren-Yan Xu
- Health Management Center, Affiliated Hospital of Yangzhou University, Yanghou University, Yangzhou, China
| |
Collapse
|
3
|
Chen R, Liu D, Zhao H, Wang X. Renal medullary perfusion differs from that in renal cortex in patients with sepsis associated acute kidney injury and correlates with renal function prognosis: A prospective cohort study. Clin Hemorheol Microcirc 2024:CH242296. [PMID: 39121113 DOI: 10.3233/ch-242296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2024]
Abstract
BACKGROUND Renal perfusion status remains poorly studied at the bedside during sepsis associated acute kidney injury (AKI). The aim of the study is to examine renal cortical and medullary perfusion using renal contrast enhanced ultrasound (CEUS) in septic patients. METHODS In this single-center, prospective longitudinal study, septic patients were enrolled. Renal ultrasonography was performed within 24 hours of ICU admission (D1), then repeated at D3, D5 and D7. Each measurement consisted of three destruction replenishment sequences that were recorded for delayed analysis with dedicated software (Vuebox). Renal cortex and medulla perfusion were quantified by measuring time to peak (TTP). Receiver operating characteristic (ROC) analysis was used to evaluate 28-day renal prognosis. RESULTS The study included 149 septic patients, including 70 non-AKI patients and 79 AKI patients. Both renal cortical and medullary TTP was longer in the AKI group than in the non-AKI group. The difference of TTP between renal cortex and medulla in AKI group was higher than that in the non-AKI group (p = 0.000). Medullary TTP on day 3 had the best performance in predicting the prognosis of 28-day renal function (AUC 0.673, 95% confidence interval 0.528-0.818, p = 0.024), and its cut-off value was 45 s with a sensitivity 52.2% and a specificity of 82.1%. Cortical TTP on day 3 also had the performance in predicting the prognosis of 28-day renal function (AUC 0.657, 95% confidence interval 0.514-0.800, p = 0.039), and its cut-off value was 33 s with a sensitivity 78.3% and a specificity of 55.0%. CONCLUSION Renal medullary perfusion alterations differ from those in cortex, with the medulla is worse. Simultaneous and dynamic assessment of cortical and medullary microcirculatory flow alterations necessary. TTP on day 3, especially medullary TTP, seems to be a relatively stable and useful indicator, which correlates with 28-day renal function prognosis in septic patients. Early correction of renal cortical and medullary perfusion alterations reduces the incidence of adverse renal events.
Collapse
Affiliation(s)
- Rongping Chen
- Peking Union Medical College Hospital, Beijing, China
| | - Dawei Liu
- Peking Union Medical College Hospital, Beijing, China
| | - Hua Zhao
- Peking Union Medical College Hospital, Beijing, China
| | - Xiaoting Wang
- Peking Union Medical College Hospital, Beijing, China
| |
Collapse
|
4
|
Xu Y, Zhu XY, Feng H, Yu XP, Wang Y, Rong X, Qi TY. The value of quantitative contrast-enhanced ultrasonography analysis in evaluating central retinal artery microcirculation in patients with diabetes mellitus: comparison with colour Doppler imaging. Clin Radiol 2024; 79:e560-e566. [PMID: 38336532 DOI: 10.1016/j.crad.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/12/2023] [Accepted: 01/12/2024] [Indexed: 02/12/2024]
Abstract
AIM To compare the efficacy of quantitative contrast-enhanced ultrasonography (CEUS) analysis and colour Doppler ultrasound (CDU) in evaluating central retinal artery (CRA) microcirculation in patients with diabetes mellitus (DM). MATERIALS AND METHODS In this prospective study, a total of 55 patients (98 eyes) with DM were enrolled as the study group. They were compared to 46 age-matched healthy volunteers (92 eyes) who were selected as the control group. Each patient underwent CDU and subsequent CEUS examination. CDU and quantitative CEUS parameters were evaluated. The diagnostic efficiency of the diagnostic performance of CEUS and CDU was evaluated and compared, and the scale thresholds of predictive indicators for the diagnosis of proliferative diabetic retinopathy (PDR) were evaluated using receiver operating characteristics (ROC) curve analyses. RESULTS Group pairwise comparisons showed that the end diastolic velocity (EDV) and arrival time (AT) of CRA were significant predictors for PDR by CDU and by quantitative CEUS analysis, respectively (all p<0.05). The ROC curve analysis showed that the area under the curve value of AT was significantly higher than that of EDV (0.875 versus 0.634, p=0.0002). Accordingly, an AT cut-off value of 1.07 seconds resulted a sensitivity of 90.62 % and a specificity of 79.31 %. CONCLUSION Quantitative CEUS analysis can improve the accuracy of clinical staging of diabetic retinopathy for the patients with DM, and the AT showed the best diagnostic efficiency.
Collapse
Affiliation(s)
- Y Xu
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - X Y Zhu
- Department of Ophthalmology, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - H Feng
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - X P Yu
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - Y Wang
- Department of Ophthalmology, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - X Rong
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China
| | - T Y Qi
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225012, China.
| |
Collapse
|
5
|
Wang Y, Wei L, Ge WS, Duan YR, Ding WJ, Lu XY, Huang YL, Chen S, Dong Y, Du P. Application of Dynamic Contrast-Enhanced Ultrasound in Evaluation the Activity of Crohn's Disease. Diagnostics (Basel) 2024; 14:672. [PMID: 38611585 PMCID: PMC11011415 DOI: 10.3390/diagnostics14070672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 03/06/2024] [Accepted: 03/20/2024] [Indexed: 04/14/2024] Open
Abstract
BACKGROUND AND OBJECTIVE The dynamic assessment of disease activity during the follow-up of patients with Crohn's disease (CD) remains a significant challenge. In this study, we aimed to identify the role of dynamic contrast-enhanced ultrasound (DCE-US) in the evaluation of activity of CD. METHODS In the retrospective study, patients diagnosed with CD in our hospital were included. All the diagnoses were confirmed by clinical symptoms and ileocolonoscopical results. All patients underwent intestinal ultrasound and contrast-enhanced ultrasound (CEUS) examinations within 1 week of the ileocolonoscopy examinations. Acuson Sequoia (Siemens Healthineers, Mountain View, CA, USA) and Resona R9 Elite (Mindray Medical Systems, China) with curved array and Line array transducers were used. The CEUS examination was performed with SonoVue (Bracco SpA, Milan, Italy). DCE-US analysis was performed by UltraOffice (version: 0.3-2010, Mindray Medical Systems, China) software. Two regions of interest (ROIs) were set in the anterior section of the infected bowel wall and its surrounding normal bowel wall 2 cm distant from the inflamed area. Time-intensity curves (TICs) were generated and quantitative perfusion parameters were obtained after curve fittings. The Simple Endoscopic Score for Crohn's disease (SES-CD) was regarded as the reference standard to evaluate the activity of CD. The receiver operating characteristic curve (ROC) analyses were used to determine the diagnostic efficiency of DCE-US quantitative parameters. RESULTS From March 2023 to November 2023, 52 CD patients were included. According to SES-CD score, all patients were divided into active group with the SES-CD score > 5 (n = 39) and inactive group SES-CD score < 5 (n = 13). Most of the active CD patients showed bowel wall thickness (BWT) > 4.2 mm (97.4%, 38/39) or mesenteric fat hypertrophy (MFH) on intestinal ultrasound (US) scan (69.2%, 27/39). Color Doppler signal of the bowel wall mostly showed spotty or short striped blood flow signal in active CD patients (56.4%, 22/39). According to CEUS enhancement patterns, most active CD patients showed a complete hyperenhancement of the entire intestinal wall (61.5%, 24/39). The TICs of active CD showed an earlier enhancement, higher peak intensity, and faster decline. Among all CEUS quantitative parameters, amplitude-derived parameters peak enhancement (PE), wash-in area under the curve (WiAUC), wash-in rate (WiR), wash-in perfusion index (WiPI), and wash-out rate (WoR) were significantly higher in active CD than in inactive CD (p < 0.05). The combined AUROC of intestinal ultrasound features and DCE-US quantitative perfusion parameters in the diagnosis of active CD was 0.987, with 97.4% sensitivity, 100% specificity, and 98.1% accuracy. CONCLUSIONS DCE-US with quantitative perfusion parameters is a potential useful noninvasive imaging method to evaluate the activity of Crohn's disease.
Collapse
Affiliation(s)
- Ying Wang
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Li Wei
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Wen-Song Ge
- Department of Gastroenterology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China;
| | - You-Rong Duan
- State Key Laboratory of Systems Medicine for Cancer, Shanghai Cancer Institute, Renji Hospital, Shanghai Jiao Tong University School of Medicine, 2200/25 Xietu Rd., Shanghai 200032, China;
| | - Wen-Jun Ding
- Department of Anorectal Surgery, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China;
| | - Xiu-Yun Lu
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Yun-Lin Huang
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Sheng Chen
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Yi Dong
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China; (Y.W.); (L.W.); (X.-Y.L.); (Y.-L.H.); (S.C.)
| | - Peng Du
- Department of Anorectal Surgery, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China;
| |
Collapse
|
6
|
Wang G, Yin C, Wang Y, Li Q, Yang D, Wang P, Nie F. Contrast-enhanced ultrasound (CEUS) characteristics of atypical-enhanced papillary thyroid carcinoma (PTC). Clin Hemorheol Microcirc 2024; 88:71-79. [PMID: 38848170 DOI: 10.3233/ch-242173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2024]
Abstract
OBJECTIVE To investigate the diagnostic value of CEUS in atypical-enhanced PTC. METHODS The clinical data, qualitative and quantitative parameters of CEUS in 177 Iso/hyper-enhanced thyroid nodules with definite pathological results were retrospectively analyzed in the Lanzhou University Second Hospital from June 2019 to January 2021. And the clinical value of CEUS in the diagnosis of atypical-enhanced PTC was assessed using univariate and multivariate analysis. RESULTS Among the 177 thyroid nodules, 59 were benign and 118 were PTC. There were significant differences in age, enhancement border, ring enhancement, speed of wash in, speed of wash out, enhancement pattern, capsule interruption, time to peak, time to wash out, RT, TPH, and TTP (P < 0.05). Multivariate analysis showed unclear enhancement border and concentric enhancement were independent risk factors for the diagnosis of atypical-enhanced PTC by CEUS. The sensitivity, specificity, PPV, NPV, and accuracy of the model in diagnosing atypical-enhanced PTC were 88.1%, 71.2%, 86.0%, 75.0%, and 82.5%, respectively. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was 0.910. CONCLUSION The diagnosis of atypical-enhanced PTC can be better performed by enhancement characteristics and time intensity curve (TIC) of CEUS, which have a good clinical application value.
Collapse
Affiliation(s)
- Guojuan Wang
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Ci Yin
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Yanfang Wang
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Qi Li
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Dan Yang
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Peihua Wang
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| | - Fang Nie
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, Gansu, China
- Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, Gansu, China
- Gansu Province Medical Engineering Research Center for Intelligence Ultrasound, Lanzhou, Gansu, China
| |
Collapse
|
7
|
Javakhishvili I, Sanikidze T, Mardaleishvili K, Momtselidze N, Urdulashvili T, Mantskava M, Prantl L, Jung F. Finding possible diagnostic markers for differentiating benign and malignant thyroid tumors on example investigate of rheological properties1. Clin Hemorheol Microcirc 2024; 87:515-526. [PMID: 38489170 DOI: 10.3233/ch-249102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
BACKGROUND The functioning of the thyroid gland is a multi-component process that in some conditions may undergo alterations. The thyroid gland is part of the endocrine system that produces the iodine-containing hormones thyroxine and triiodothyronine. Thyroid hormones, control metabolism and energy, growth processes, maturation of tissues and organs, regulation of blood flow, and, therefore, providing vital functions of the body. The role of thyroid hormones in the regulation of blood flow is determined by the intensity of their production and the quantity in the blood. Presumably, in case of oncological and non-oncological diseases of the thyroid gland, the fluidity of the blood, which depends on the rheological properties, will be different. OBJECTIVE Our aim was investigating rheological characteristics for studying of changes of rheology in patients with thyrotoxicosis, with benign tumor pathology of the thyroid gland, with thyroid cancer and finding possible diagnostic markers for differentiating benign and malignant thyroid tumors. METHODS In this regard, we examined, using modern methods accepted in clinical practice, a standard list of recommended diagnostic tests in the group of patients (thyrotoxicosis: n = 25; benign tumor: n = 47), thyroid cancer: n = 35) and control group (n = 15), and with new original methods, parameters that describe the rheological properties of the blood, such as blood rheological index, volume, thickness, surface area of erythrocytes, erythrocyte aggregation index, deformation index, plasma viscosity, hematocrits. RESULTS Against the background of relative changes in the studied values, it is necessary to pay attention to the fact that erythrocyte aggregation in patients with a benign form and control, as well as in patients with a malignant form and control, differ significantly from each other, in addition, there is a significant difference between aggregation in the group of patients with benign and control aggregation. malignant forms of the disease. It is significant that aggregability differs in patients with thyrotoxicosis and in controls. This indicates that erythrocyte aggregation is particularly informative. The blood rheological index most clearly demonstrated the difference between benign and malignant forms of the disease. Significantly changed compared to control in various forms of thyroid diseases. CONCLUSION Additional diagnostic markers for differentiating benign and malignant thyroid tumors may be consideredeerythrocyte aggregation index and blood rheological index.
Collapse
Affiliation(s)
| | - T Sanikidze
- Tbilisi State Medical University, Tbilisi, Georgia
| | | | - N Momtselidze
- Ivane Beritashvilis Center of Experimental Biomedicine, Tbilisi, Georgia
| | - T Urdulashvili
- Ivane Beritashvilis Center of Experimental Biomedicine, Tbilisi, Georgia
| | - M Mantskava
- Ivane Beritashvilis Center of Experimental Biomedicine, Tbilisi, Georgia
| | - L Prantl
- University Hospital Regensburg, Regensburg, Germany
| | - F Jung
- Brandenburg University of Technology, Cottbus Senftenberg, Germany
| |
Collapse
|
8
|
Xu YD, Tang Y, Zhang Q, Zhao ZY, Zhao CK, Fan PL, Jin YJ, Ji ZB, Han H, Xu HX, Shi YL, Xu BH, Li XL. Automatic detection of thyroid nodules with a real-time artificial intelligence system in a real clinical scenario and the associated influencing factors. Clin Hemorheol Microcirc 2024; 87:437-450. [PMID: 38489169 DOI: 10.3233/ch-242099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
BACKGROUND At present, most articles mainly focused on the diagnosis of thyroid nodules by using artificial intelligence (AI), and there was little research on the detection performance of AI in thyroid nodules. OBJECTIVE To explore the value of a real-time AI based on computer-aided diagnosis system in the detection of thyroid nodules and to analyze the factors influencing the detection accuracy. METHODS From June 1, 2022 to December 31, 2023, 224 consecutive patients with 587 thyroid nodules were prospective collected. Based on the detection results determined by two experienced radiologists (both with more than 15 years experience in thyroid diagnosis), the detection ability of thyroid nodules of radiologists with different experience levels (junior radiologist with 1 year experience and senior radiologist with 5 years experience in thyroid diagnosis) and real-time AI were compared. According to the logistic regression analysis, the factors influencing the real-time AI detection of thyroid nodules were analyzed. RESULTS The detection rate of thyroid nodules by real-time AI was significantly higher than that of junior radiologist (P = 0.013), but lower than that of senior radiologist (P = 0.001). Multivariate logistic regression analysis showed that nodules size, superior pole, outside (near carotid artery), close to vessel, echogenicity (isoechoic, hyperechoic, mixed-echoic), morphology (not very regular, irregular), margin (unclear), ACR TI-RADS category 4 and 5 were significant independent influencing factors (all P < 0.05). With the combination of real-time AI and radiologists, junior and senior radiologist increased the detection rate to 97.4% (P < 0.001) and 99.1% (P = 0.015) respectively. CONCLUSONS The real-time AI has good performance in thyroid nodule detection and can be a good auxiliary tool in the clinical work of radiologists.
Collapse
Affiliation(s)
- Ya-Dan Xu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
| | - Yang Tang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Qi Zhang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Zheng-Yong Zhao
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Chong-Ke Zhao
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Pei-Li Fan
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Yun-Jie Jin
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Zheng-Biao Ji
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Hong Han
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
| | - Hui-Xiong Xu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
- Shanghai Institute of Medical Imaging, Shanghai, China
| | | | - Ben-Hua Xu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| | - Xiao-Long Li
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| |
Collapse
|
9
|
Jung EM, Stroszczynski C, Jung F. Advanced multimodal imaging of solid thyroid lesions with artificial intelligence-optimized B-mode, elastography, and contrast-enhanced ultrasonography parametric and with perfusion imaging: Initial results. Clin Hemorheol Microcirc 2023:CH239102. [PMID: 37092219 PMCID: PMC10357218 DOI: 10.3233/ch-239102] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26-81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4-12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resono R9/Mindray) by an experienced examiner with independent reading. The evaluation was performed according to TI-RADS III-V.The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9-21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V.Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings.
Collapse
Affiliation(s)
- E M Jung
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - C Stroszczynski
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| | - F Jung
- Institute of Diagnostic Radiology and Interdisciplinary Ultrasound Department, University Hospital, Regensburg, Germany
| |
Collapse
|
10
|
Zheng Z, Zhang S, Zheng C, Wang R, Zhang Y, Chen P, Zhou S, Luo B, Di N. Qualitative and quantitative features of deep endometriosis in contrast-enhanced ultrasound: An initial experience and literature review. Clin Hemorheol Microcirc 2023; 85:73-82. [PMID: 37522202 DOI: 10.3233/ch-231843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
PURPOSE This research aims to present the findings of contrast-enhanced ultrasound (CEUS) in a series of patients with proven deep endometriosis (DE) and provide an updated literature review. MATERIALS AND METHODS Between January 2018 and October 2022, seven patients with DE lesions had their imaging and medical records retrospectively reviewed. Clinical data, recorded images of a standardized conventional B-mode ultrasound, and Sonovue® CEUS were interpreted by two blinded, independent, experienced radiologists in consensus. The enhanced characteristics of the DE lesion on CEUS were also assessed using VueBox® software quantitatively. RESULTS DE lesion appeared as irregular hypoechoic or heterogeneous on conventional ultrasound with dotted blood flow signal on color Doppler. Six of seven DE lesions showed heterogeneous hypo-enhancement in arterial phases. All the lesions showed a heterogeneous washout rapidly that began in the late arterial phase. In quantified analysis, the mean relative peak enhancement compared with adjacent tissue was 0.47±0.25. CONCLUSION Our findings and literature review suggested that CEUS could be a feasible and promising non-invasive modality for diagnosing DE.
Collapse
Affiliation(s)
- Zijie Zheng
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Shen Zhang
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Cheng Zheng
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Ruxue Wang
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yanping Zhang
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Peixin Chen
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Shanglan Zhou
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Baoming Luo
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Na Di
- Department of Ultrasound, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
- Department of Ultrasound, the First People's Hospital of Kashi Prefecture, Xinjiang, China
| |
Collapse
|
11
|
Li N, Hu Z, Liu Y, Ding J, Han P, Jing X, Kan Y. Dynamic contrast-enhanced ultrasound characteristics of renal tumors: VueBox™ quantitative analysis. Clin Hemorheol Microcirc 2023; 85:341-354. [PMID: 37742629 DOI: 10.3233/ch-231750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
BACKGROUND VueBoxtrademark has been used for contrast analysis in DCE-US-based quantitative research. OBJECTIVE Aim of this study was to use the enhancement-mode and VueBoxtrademark parameters to further evaluate the differential diagnostic value of DCE-US for renal tumors. METHODS 24 patients with renal tumors, including 7 benign and 17 malignant, were retrospectively analyzed.The DCE-US enhancement-mode and VueBoxtrademark parameters correlated with the histological analyses of tumors were obtained and analyzed. RESULTS The benign and malignant renal tumors showed significant differences in enhancement degree (P = 0.017) and presence of a pseudocapsule (P = 0.009) and in the VueBoxtrademark parameters FT (P = 0.045) and RT (P = 0.039). Receiver operating characteristic analysis for differential diagnosis of benign and malignant renal tumors showed that AUC for a combination of enhancement degree and presence of a pseudocapsule was greater (AUC = 0.815) than the values for either parameter of enhancement mode alone. Similarly, the AUC for a combination of RT and FT was greater (AUC = 0.798) than the values for RT or FT alone. A comprehensive index obtaining by combining the enhancement-mode and VueBoxtrademark parameters showed the largest AUC (AUC = 0.916) with relatively high accuracy (87.50%), sensitivity (76.50%), and specificity (85.70%). CONCLUSIONS DCE-US with enhancement mode and quantitative analysis can facilitate preoperative differential diagnosis of benign and malignant renal tumors.
Collapse
Affiliation(s)
- Ning Li
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
| | - Ziyue Hu
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Yang Liu
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
| | - Jianmin Ding
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Pengcheng Han
- College of Stomatology, Tianjin Medical University, Tianjin, China
| | - Xiang Jing
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| | - Yanmin Kan
- Department of Ultrasound, North China University of Science and Technology Affiliated Hospital, Tangshan, Hebei, China
- Department of Ultrasound, The Third Central Hospital of Tianjin, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
| |
Collapse
|
12
|
Miao H, Zhong J, Xing X, Sun J, Wu J, Wu C, Yuan Y, Zhou X, Wang H. A nomogram based on the risk factors of cervical lymph node metastasis in papillary thyroid carcinoma coexistent with Hashimoto's thyroiditis. Clin Hemorheol Microcirc 2023; 85:235-247. [PMID: 37718783 DOI: 10.3233/ch-221673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
OBJECTIVE The purpose of this study was to explore the risk factors of cervical lymph node metastasis(LNM) in papillary thyroid carcinoma(PTC) coexistent with Hashimoto's thyroiditis(HT). METHODS The clinical data of patients who underwent thyroid operation between November 2016 and January 2020 in our hospital were analyzed retrospectively. The association between sonographic features and the risk factors of cervical LNM in PTC coexistent with HT was analyzed and a nomogram based on the risk factors was built. RESULTS Age, US features as calcification, blood flow type, distance between thyroid nodule and fibrous capsule were risk factors of cervical LNM(P < 0.05).Size, SWVmax and SWVmean of thyroid nodule, SWVratio between thyroid nodule and thyroid gland were higher in PTCs with LNM than those without LNM(P < 0.05). The ROC curve showed that the cutoff value of SWVratio for predicting LNM was 1.29 (Sensitivity = 0.806, Specificity = 0.775, AUC = 0.823, P < 0.001). Based on the risk factors above, a relevant nomogram prediction model was established. The model verification showed that the C-index of the modeling set was 0.814, indicating that the nomogram model had good predicted accuracy. CONCLUSION Based on the risk factors above, a relevant nomogram prediction model was established. The model verification showed that the C-index of the modeling set was 0.814, indicating that the nomogram model had good predicted accuracy. The nomogram based on the risk factors above had good prediction ability, which could optimize thyroidectomy and cervical lymph node dissection and improving prognosis.
Collapse
Affiliation(s)
- Huanhuan Miao
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Jingwen Zhong
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Xuesha Xing
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Jiawei Sun
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Jiaqi Wu
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Chengwei Wu
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Yan Yuan
- Department of Ultrasound, Heilongjiang Red Cross Sengong General Hospital, Harbin, China
| | - Xianli Zhou
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Hongbo Wang
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| |
Collapse
|
13
|
Lian KM, Lin T. Virtual touch tissue imaging for differential diagnosis in ACR TI-RADS category 3-4 thyroid nodules: Conservative and aggressive methods. Clin Hemorheol Microcirc 2023; 85:123-134. [PMID: 37718784 DOI: 10.3233/ch-231694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
PURPOSE Many Thyroid Imaging Reporting and Data System (TI-RADS) category 3-4 nodules are benign. Our study aimed to add virtual touch tissue imaging (VTI) to TI-RADS using two methods, namely conservative and aggressive, and to explore which method had better diagnostic performance and which method avoided more unnecessary biopsies. METHODS From January 2016 to December 2021, we included 121 thyroid nodules classified as TI-RADS category 3-4 in 115 consecutive patients in this retrospective study. This study used the reference standard for pathological diagnosis by surgical resection or biopsy. The diagnostic performance of the different methods was evaluated and compared by receiver operating characteristic (ROC) and area under the ROC curve (AUC). RESULTS In this study, the aggressive approach had the best diagnostic performance among TI-RADS alone, the conservative approach, and the aggressive approach (AUC: 0.863 versus 0.598, P = 0.0007; 0.863 versus 0.755, P = 0.0067). When we used an aggressive approach, 75.44% (43/57) of the 57 false-positive nodes diagnosed by TI-RADS were appropriately downgraded from TI-RADS category 4 to category 3, avoiding unnecessary biopsies. CONCLUSION VTI improves the diagnostic performance of TI-RADS. The aggressive approach of combining the TI-RADS with VTI would help reduce unnecessary biopsies.
Collapse
Affiliation(s)
- Kai-Mei Lian
- Department of Ultrasound, The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Teng Lin
- Department of Ultrasound, The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China
| |
Collapse
|