1
|
Edelman RR, Pursnani A. Editorial for "Assessment of Pulmonary Arteries Hemodynamics and Its Relationship With Cardiac Remodeling and Myocardial Fibrosis in Athletes With Four-Dimensional Flow MRI". J Magn Reson Imaging 2024; 60:388-389. [PMID: 37830255 DOI: 10.1002/jmri.29066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 09/29/2023] [Indexed: 10/14/2023] Open
Affiliation(s)
- Robert R Edelman
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Amit Pursnani
- Department of Medicine, NorthShore University HealthSystem, Evanston, Illinois, USA
- Department of Medicine, Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA
| |
Collapse
|
2
|
Saitta S, Carioni M, Mukherjee S, Schönlieb CB, Redaelli A. Implicit neural representations for unsupervised super-resolution and denoising of 4D flow MRI. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 246:108057. [PMID: 38335865 DOI: 10.1016/j.cmpb.2024.108057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 02/02/2024] [Accepted: 02/02/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND AND OBJECTIVE 4D flow magnetic resonance imaging provides time-resolved blood flow velocity measurements, but suffers from limitations in spatio-temporal resolution and noise. In this study, we investigated the use of sinusoidal representation networks (SIRENs) to improve denoising and super-resolution of velocity fields measured by 4D flow MRI in the thoracic aorta. METHODS Efficient training of SIRENs in 4D was achieved by sampling voxel coordinates and enforcing the no-slip condition at the vessel wall. A set of synthetic measurements were generated from computational fluid dynamics simulations, reproducing different noise levels. The influence of SIREN architecture was systematically investigated, and the performance of our method was compared to existing approaches for 4D flow denoising and super-resolution. RESULTS Compared to existing techniques, a SIREN with 300 neurons per layer and 20 layers achieved lower errors (up to 50% lower vector normalized root mean square error, 42% lower magnitude normalized root mean square error, and 15% lower direction error) in velocity and wall shear stress fields. Applied to real 4D flow velocity measurements in a patient-specific aortic aneurysm, our method produced denoised and super-resolved velocity fields while maintaining accurate macroscopic flow measurements. CONCLUSIONS This study demonstrates the feasibility of using SIRENs for complex blood flow velocity representation from clinical 4D flow, with quick execution and straightforward implementation.
Collapse
Affiliation(s)
- Simone Saitta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| | - Marcello Carioni
- Department of Applied Mathematics, University of Twente, 7500AE Enschede, the Netherlands
| | - Subhadip Mukherjee
- Department of Electronics & Electrical Communication Engineering, Indian Institute of Technology (IIT) Kharagpur, India
| | - Carola-Bibiane Schönlieb
- Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge, UK
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
3
|
Ma P, Zhu L, Wen R, Lv F, Li Y, Li X, Zhang Z. Revolutionizing vascular imaging: trends and future directions of 4D flow MRI based on a 20-year bibliometric analysis. Quant Imaging Med Surg 2024; 14:1873-1890. [PMID: 38415143 PMCID: PMC10895087 DOI: 10.21037/qims-23-1227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 12/08/2023] [Indexed: 02/29/2024]
Abstract
Background Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a promising new technology with potential clinical value in hemodynamic quantification. Although an increasing number of articles on 4D flow MRI have been published over the past decades, few studies have statistically analyzed these published articles. In this study, we aimed to perform a systematic and comprehensive bibliometric analysis of 4D flow MRI to explore the current hotspots and potential future directions. Methods The Web of Science Core Collection searched for literature on 4D flow MRI between 2003 and 2022. CiteSpace was utilized to analyze the literature data, including co-citation, cooperative network, cluster, and burst keyword analysis. Results A total of 1,069 articles were extracted for this study. The main research hotspots included the following: quantification and visualization of blood flow in different clinical settings, with keywords such as "cerebral aneurysm", "heart", "great vessel", "tetralogy of Fallot", "portal hypertension", and "stiffness"; optimization of image acquisition schemes, such as "resolution" and "reconstruction"; measurement and analysis of flow components and patterns, as indicated by keywords "pattern", "KE", "WSS", and "fluid dynamics". In addition, international consensus for metrics derived from 4D flow MRI and multimodality imaging may also be the future research direction. Conclusions The global domain of 4D flow MRI has grown over the last 2 decades. In the future, 4D flow MRI will evolve towards becoming a relatively short scan duration with adequate spatiotemporal resolution, expansion into the diagnosis and treatment of vascular disease in other related organs, and a shift in focus from vascular structure to function. In addition, artificial intelligence (AI) will assist in the clinical promotion and application of 4D flow MRI.
Collapse
Affiliation(s)
- Peisong Ma
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Lishu Zhu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ru Wen
- Department of Radiology, Guizhou Provincial People Hospital, Guiyang, China
| | - Fajin Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Yongmei Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xinyou Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhiwei Zhang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
4
|
Oh Y, Heo CM, Gwoo S, Huh H, Park S, Heo W. Effect of flow reduction surgery in a patient with high flow arteriovenous fistula with aortic dissection using 4D flow magnetic resonance imaging: A case report. J Vasc Access 2023:11297298231209778. [PMID: 38142278 DOI: 10.1177/11297298231209778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2023] Open
Abstract
This study aimed to investigate cardiovascular function in a patient with high-flow arteriovenous fistula (AVF) who underwent aortic dissection (AD) using four-dimensional (4D) flow magnetic resonance imaging (MRI) as well as analyze the effect of flow reduction surgery on AD. On March 12, 2017, a 60-year-old woman underwent emergency surgery for AD. After that, she experienced acute kidney injury, and hemodialysis was initiated. On April 24, 2017, a left brachiocephalic arteriovenous fistula (AVF) was created to facilitate her dialysis. However, after 5 years, the patient presented with a high-flow AVF, and a flow reduction surgery was performed on March 11, 2022. To evaluate the procedure's effectiveness, we measured the changes in left ventricular (LV) function and blood flow in the aorta and vascular access before and after surgery using 4D flow MRI. Notable changes were observed in LV function, blood flow in the aorta before and after the surgery, and maximum velocity and flow volume after surgery. During the 6-month follow-up after the surgery, the maximum velocity and flow volume in the aorta and vascular access were reduced; also, indicators such as LV volume, cardiac output, cardiac index, and LV mass were improved. In patients with high-flow AVF, flow reduction surgery should be considered as it may improve LV function and reduce the risk of AD recurrence by lowering the flow volume of the aorta.
Collapse
Affiliation(s)
- Yeongrok Oh
- Department of Internal Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
| | - Chang Min Heo
- Department of Internal Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
| | - Sangeon Gwoo
- Vascular Access Center, Lifeline Clinic, Busan, Korea
| | - Hyungkyu Huh
- Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Korea
| | - Sungho Park
- Kangwon National University, Chuncheon, Korea
| | - Woon Heo
- Vascular Access Center, Lifeline Clinic, Busan, Korea
| |
Collapse
|
5
|
Marin-Castrillon DM, Geronzi L, Boucher A, Lin S, Morgant MC, Cochet A, Rochette M, Leclerc S, Ambarki K, Jin N, Aho LS, Lalande A, Bouchot O, Presles B. Segmentation of the aorta in systolic phase from 4D flow MRI: multi-atlas vs. deep learning. MAGMA (NEW YORK, N.Y.) 2023; 36:687-700. [PMID: 36800143 DOI: 10.1007/s10334-023-01066-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 11/26/2022] [Accepted: 01/24/2023] [Indexed: 02/18/2023]
Abstract
OBJECTIVE In the management of the aortic aneurysm, 4D flow magnetic resonance Imaging provides valuable information for the computation of new biomarkers using computational fluid dynamics (CFD). However, accurate segmentation of the aorta is required. Thus, our objective is to evaluate the performance of two automatic segmentation methods on the calculation of aortic wall pressure. METHODS Automatic segmentation of the aorta was performed with methods based on deep learning and multi-atlas using the systolic phase in the 4D flow MRI magnitude image of 36 patients. Using mesh morphing, isotopological meshes were generated, and CFD was performed to calculate the aortic wall pressure. Node-to-node comparisons of the pressure results were made to identify the most robust automatic method respect to the pressures obtained with a manually segmented model. RESULTS Deep learning approach presented the best segmentation performance with a mean Dice similarity coefficient and a mean Hausdorff distance (HD) equal to 0.92+/- 0.02 and 21.02+/- 24.20 mm, respectively. At the global level HD is affected by the performance in the abdominal aorta. Locally, this distance decreases to 9.41+/- 3.45 and 5.82+/- 6.23 for the ascending and descending thoracic aorta, respectively. Moreover, with respect to the pressures from the manual segmentations, the differences in the pressures computed from deep learning were lower than those computed from multi-atlas method. CONCLUSION To reduce biases in the calculation of aortic wall pressure, accurate segmentation is needed, particularly in regions with high blood flow velocities. Thus, the deep learning segmen-tation method should be preferred.
Collapse
Affiliation(s)
| | | | - Arnaud Boucher
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
| | - Siyu Lin
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
| | - Marie-Catherine Morgant
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
- Department of cardiovascular and thoracic surgery, University Hospital of Dijon, Dijon, France
| | - Alexandre Cochet
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
- Medical Imaging Department, University Hospital of Dijon, Dijon, France
| | | | - Sarah Leclerc
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
| | | | - Ning Jin
- Siemens Medical Solutions, Nancy, France
| | - Ludwig Serge Aho
- Department of Epidemiology and Hygiene, University Hospital of Dijon, Dijon, France
| | - Alain Lalande
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
- Medical Imaging Department, University Hospital of Dijon, Dijon, France
| | - Olivier Bouchot
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France
- Department of cardiovascular and thoracic surgery, University Hospital of Dijon, Dijon, France
| | - Benoit Presles
- Imaging and Artificial Vision Research Laboratory, University of Burgundy, Dijon, France.
| |
Collapse
|
6
|
Jung EC, Lee GH, Shim EB, Ha H. Assessing the impact of turbulent kinetic energy boundary conditions on turbulent flow simulations using computational fluid dynamics. Sci Rep 2023; 13:14638. [PMID: 37670027 PMCID: PMC10480182 DOI: 10.1038/s41598-023-41324-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 08/24/2023] [Indexed: 09/07/2023] Open
Abstract
Computational fluid dynamics has been widely used to study hemodynamics, but accurately determining boundary conditions for turbulent blood flow remains challenging. This study aims to investigate the effect of patient-specific turbulence boundary conditions on the accuracy of turbulent flow simulation. Using a stenosis model with 50% severity in diameter, the post-stenosis turbulence flow region was simulated with different planes to obtain inlet boundary conditions and simulate downstream flows. The errors of simulated flow fields obtained with turbulence kinetic energy (TKE) boundary data and arbitrary turbulence intensity were compared. Additionally, the study tested various TKE data resolutions and noise levels to simulate experimental environments. The mean absolute error of velocity and TKE was investigated with various turbulence intensities and TKE mapping. While voxel size and signal-to-noise ratio of the TKE data affected the results, simulation with SNR > 5 and voxel size < 10% resulted in better accuracy than simulations with turbulence intensities. The simulation with appropriate TKE boundary data resulted in a more accurate velocity and turbulence field than those with arbitrary turbulence intensity boundary conditions. The study demonstrated the potential improvement of turbulent blood flow simulation with patient-specific turbulence boundary conditions, which can be obtained from recent measurement techniques.
Collapse
Affiliation(s)
- Eui Cheol Jung
- Kangwon Institute of Inclusive Technology, Kangwon National University, 1, Kangwondaehak-Gil, Chuncheon, 24341, Republic of Korea
| | - Gyu-Han Lee
- Institute of Medical Devices, Kangwon National University, 1, Kangwondaehak-Gil, Chuncheon, 24341, Republic of Korea
| | - Eun Bo Shim
- Department of Mechanical and Biomedical Engineering, Kangwon National University, 1, Kangwondaehak-Gil, Chuncheon, 24341, Republic of Korea
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, 1, Kangwondaehak-Gil, Chuncheon, 24341, Republic of Korea.
| |
Collapse
|
7
|
Zheng AS, Yu HX. Value of clinical applications of differential pressure and relative pressure imaging in the left ventricle. World J Clin Cases 2023; 11:3967-3975. [PMID: 37388805 PMCID: PMC10303603 DOI: 10.12998/wjcc.v11.i17.3967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 04/15/2023] [Accepted: 05/06/2023] [Indexed: 06/12/2023] Open
Abstract
Regional pressure differences between sites within the left ventricular cavity have long been identified, and the potential clinical value of diastolic and systolic intraventricular pressure differences (IVPDs) is of increasing interest. This study concluded that the IVPD plays an important role in ventricular filling and emptying and is a reliable indicator of ventricular relaxation, elastic recoil, diastolic pumping, and effective left ventricular filling. Relative pressure imaging, as a novel and potentially clinically applicable measure of left IVPDs, enables early and more comprehensive identification of the temporal and spatial characteristics of IVPD. In the future, as research related to relative pressure imaging continues, this measurement method has the possibility to become more refined and serve as an additional clinical aid that can replace the gold standard cardiac catheterization technique for the diagnosis of diastolic dysfunction.
Collapse
Affiliation(s)
- An-Sheng Zheng
- Department of Ultrasound Medicine, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou 450002, Henan Province, China
| | - Hong-Xia Yu
- Department of Ultrasound Medicine, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou 450002, Henan Province, China
| |
Collapse
|
8
|
Franco P, Ma L, Schnell S, Carrillo H, Montalba C, Markl M, Bertoglio C, Uribe S. Comparison of Improved Unidirectional Dual Velocity-Encoding MRI Methods. J Magn Reson Imaging 2023; 57:763-773. [PMID: 35716109 DOI: 10.1002/jmri.28305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 05/30/2022] [Accepted: 05/31/2022] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND In phase-contrast (PC) MRI, several dual velocity encoding methods have been proposed to robustly increase velocity-to-noise ratio (VNR), including a standard dual-VENC (SDV), an optimal dual-VENC (ODV), and bi- and triconditional methods. PURPOSE To develop a correction method for the ODV approach and to perform a comparison between methods. STUDY TYPE Case-control study. POPULATION Twenty-six volunteers. FIELD STRENGTH/SEQUENCE 1.5 T phase-contrast MRI with VENCs of 50, 75, and 150 cm/second. ASSESSMENT Since we acquired single-VENC protocols, we used the background phase from high-VENC (VENCH ) to reconstruct the low-VENC (VENCL ) phase. We implemented and compared the unwrapping methods for different noise levels and also developed a correction of the ODV method. STATISTICAL TESTS Shapiro-Wilk's normality test, two-way analysis of variance with homogeneity of variances was performed using Levene's test, and the significance level was adjusted by Tukey's multiple post hoc analysis with Bonferroni (P < 0.05). RESULTS Statistical analysis revealed no extreme outliers, normally distributed residuals, and homogeneous variances. We found statistically significant interaction between noise levels and the unwrapping methods. This implies that the number of non-unwrapped pixels increased with the noise level. We found that for β = VENCL /VENCH = 1/2, unwrapping methods were more robust to noise. The post hoc test showed a significant difference between the ODV corrected and the other methods, offering the best results regarding the number of unwrapped pixels. DATA CONCLUSIONS All methods performed similarly without noise, but the ODV corrected method was more robust to noise at the price of a higher computational time. LEVEL OF EVIDENCE 4 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Pamela Franco
- Biomedical Imaging Center, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.,Electrical Engineering Department, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, Chile.,Instituto Milenio Intelligent Healthcare Engineering, Santiago, Chile
| | - Liliana Ma
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| | - Susanne Schnell
- Institut für Physik, Universität Greifswald, Greifswald, Germany
| | - Hugo Carrillo
- Center for Mathematical Modeling, Universidad de Chile, Santiago, Chile.,Inria Chile Research Center, Santiago, Chile
| | - Cristian Montalba
- Biomedical Imaging Center, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, Chile.,Radiology Department, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| | | | - Sergio Uribe
- Biomedical Imaging Center, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, Chile.,Instituto Milenio Intelligent Healthcare Engineering, Santiago, Chile.,Radiology Department, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
9
|
Bai X, Fu M, Li Z, Gao P, Zhao H, Li R, Sui B. Distribution and regional variation of wall shear stress in the curved middle cerebral artery using four-dimensional flow magnetic resonance imaging. Quant Imaging Med Surg 2022; 12:5462-5473. [PMID: 36465823 PMCID: PMC9703110 DOI: 10.21037/qims-22-67] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 08/30/2022] [Indexed: 12/05/2023]
Abstract
BACKGROUND To investigate the distribution and regional variation of wall shear stress (WSS) in the curved middle cerebral artery (MCA) in healthy individuals using four-dimensional (4D) flow magnetic resonance imaging (MRI). METHODS A total of 44 healthy participants (18 males; mean ages: 27.16±5.69 years) were included in this cross-sectional study. The WSS parameters of mean, minimum, and maximum values, the coefficient of variation of time-averaged WSS (TAWSSCV), and the maximum values of the oscillatory shear index (OSI) were calculated and compared in the curved proximal (M1) segments. Three cross-sectional planes were selected: the location perpendicular to the beginning of the long axis of the curved M1 segment of the MCA (proximal section), the most curved M1 location (curved M1 section), and the location before the insular (M2) segment bifurcation (distal section). The WSS and OSI parameters of the proximal, curved, and distal sections of the curved M1 segment were compared, including the inner and outer curvatures of the curved M1 section. RESULTS Of the curved M1 segments, the curved M1 section had significantly lower minimum TAWSS values than the proximal (P=0.031) and distal sections (P=0.002), and the curved M1 section had significantly higher maximum OSI values than the distal section (P=0.001). The TAWSSCV values at the curved M1 section were significantly higher than the proximal (P=0.001) and distal sections (P<0.001). At the curved M1 section, the inner curvature showed a significantly lower minimum TAWSS (P=0.013) and higher maximum OSI values (P=0.002) than the outer curvature. CONCLUSIONS There are distribution variation of WSS and OSI parameters at the curved M1 section of the curved MCA, and the inner curvature of the curved M1 section has the lowest WSS and highest OSI distribution. The local hemodynamic features of the curved MCA may be related to the predilection for atherosclerotic plaque development.
Collapse
Affiliation(s)
- Xiaoyan Bai
- Tiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Mingzhu Fu
- Center for Biomedical Imaging Research, Biomedical Engineering Department, School of Medicine, Tsinghua University, Beijing, China
| | - Zhiye Li
- Tiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Peiyi Gao
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Haiqing Zhao
- Department of Radiology, Beijing Chui Yang Liu Hospital, Beijing, China
| | - Rui Li
- Center for Biomedical Imaging Research, Biomedical Engineering Department, School of Medicine, Tsinghua University, Beijing, China
| | - Binbin Sui
- Tiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| |
Collapse
|
10
|
Jung HJ, Choo KS. Pilot study on the effect of grape seed proanthocyanidin extract on inferior vene cava blood flow in patients with chronic venous insufficiency using 4D flow MRI. Medicine (Baltimore) 2022; 101:e31792. [PMID: 36401399 PMCID: PMC9678586 DOI: 10.1097/md.0000000000031792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Four-dimensional (4D) flow magnetic resonance imaging (MRI) was used to objectively assess changes in blood flow velocity in patients with chronic venous insufficiency (CVI) who underwent stocking treatment alone and stocking combined with Grape seed proanthocyanidin extract (GSPE) treatment. METHODS Patients diagnosed with CVI were recruited from August 31, 2018 to December 31, 2020. A total of 23 participants were selected, with 10 and 13 patients in the stocking treatment and stocking + GSPE treatment groups, respectively. The blood flow velocity (Th-plane peak and average velocities) was calculated using 4D flow MRI. A paired t test was used to evaluate the differences in blood flow velocity before and after treatment. RESULTS In the stocking treatment group, The Th-Plane peak velocity increased by 2.48 ± 5.05 cm/s after treatment (P = .16). In the stocking + GSPE treatment group, the Th-Plane peak velocity increased by 4.85 ± 5.57 cm/s after treatment (P < .001). CONCLUSION The blood flow velocity on 4D flow MRI was significantly increased in participants who underwent GSPE, highlighting the potential of GSPE for CVI treatment.
Collapse
Affiliation(s)
- Hyuk Jae Jung
- Endovascular and Vascular and Transplantation Division, Department of Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Busan, Korea
| | - Ki Seok Choo
- Department of Radiology, Pusan National University School of Medicine and Medical Research Institute, Busan National University Yangsan Hospital, Busan, Korea
| |
Collapse
|
11
|
Terada M, Takehara Y, Isoda H, Wakayama T, Nozaki A. Technical Background for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:267-277. [PMID: 35153275 PMCID: PMC9680548 DOI: 10.2463/mrms.rev.2021-0104] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 11/20/2021] [Indexed: 10/27/2023] Open
Abstract
Recently, the hemodynamic assessments with 3D cine phase-contrast (PC) MRI (4D flow MRI) have attracted considerable attention from clinicians. Unlike 2D cine PC MRI, the technique allows for cardiac phase-resolved data acquisitions of flow velocity vectors within the entire FOV during a clinically viable period. Thus, the method has enabled retrospective flowmetry in the spatial and temporal axes, which are essential to derive hemodynamic parameters related to vascular homeostasis and those to the progression of the pathologies. Accelerations in imaging are critical for this technology to be clinically viable; however, a high SNR or velocity-to-noise ratio (VNR) is also vital for accurate flow measurements. In this chapter, the technologies enabling this difficult balance are discussed.
Collapse
Affiliation(s)
- Masaki Terada
- Department of Diagnostic Radiologic Technology, Iwata City Hospital, Iwata, Shizuoka, Japan
| | - Yasuo Takehara
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Haruo Isoda
- Department of Brain & Mind Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | | | - Atsushi Nozaki
- MR Applications and Workflow, GE Healthcare Japan, Tokyo, Japan
| |
Collapse
|
12
|
Ha H, Huh HK, Park KJ, Dyverfeldt P, Ebbers T, Kim DH, Yang DH. In-vitro and In-Vivo Assessment of 4D Flow MRI Reynolds Stress Mapping for Pulsatile Blood Flow. Front Bioeng Biotechnol 2021; 9:774954. [PMID: 34950643 PMCID: PMC8691458 DOI: 10.3389/fbioe.2021.774954] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 11/16/2021] [Indexed: 02/03/2023] Open
Abstract
Imaging hemodynamics play an important role in the diagnosis of abnormal blood flow due to vascular and valvular diseases as well as in monitoring the recovery of normal blood flow after surgical or interventional treatment. Recently, characterization of turbulent blood flow using 4D flow magnetic resonance imaging (MRI) has been demonstrated by utilizing the changes in signal magnitude depending on intravoxel spin distribution. The imaging sequence was extended with a six-directional icosahedral (ICOSA6) flow-encoding to characterize all elements of the Reynolds stress tensor (RST) in turbulent blood flow. In the present study, we aimed to demonstrate the feasibility of full RST analysis using ICOSA6 4D flow MRI under physiological conditions. First, the turbulence analysis was performed through in vitro experiments with a physiological pulsatile flow condition. Second, a total of 12 normal subjects and one patient with severe aortic stenosis were analyzed using the same sequence. The in-vitro study showed that total turbulent kinetic energy (TKE) was less affected by the signal-to-noise ratio (SNR), however, maximum principal turbulence shear stress (MPTSS) and total turbulence production (TP) had a noise-induced bias. Smaller degree of the bias was observed for TP compared to MPTSS. In-vivo study showed that the subject-variability on turbulence quantification was relatively low for the consistent scan protocol. The in vivo demonstration of the stenosis patient showed that the turbulence analysis could clearly distinguish the difference in all turbulence parameters as they were at least an order of magnitude larger than those from the normal subjects.
Collapse
Affiliation(s)
- Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Hyung Kyu Huh
- Daegu-Gyeongbuk Medical Innovation Foundation, Medical Device Development Center, Daegu, South Korea
| | - Kyung Jin Park
- Department of Electrical and Electronic Engineering, Yonsei Univeristy, Seoul, South Korea.,Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Petter Dyverfeldt
- Department of Health, Medicine and Caring Science, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Department of Health, Medicine and Caring Science, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Dae-Hee Kim
- Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Dong Hyun Yang
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| |
Collapse
|
13
|
Ha SY, Kang Y, Lee HJ, Hwang M, Baik J, Park S. Intracranial Flow Velocity Quantification Using Non-Contrast Four-Dimensional Flow MRI: A Prospective Comparative Study with Transcranial Doppler Ultrasound. Diagnostics (Basel) 2021; 12:diagnostics12010023. [PMID: 35054190 PMCID: PMC8774649 DOI: 10.3390/diagnostics12010023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/12/2021] [Accepted: 12/20/2021] [Indexed: 11/30/2022] Open
Abstract
Four-dimensional (4D) flow magnetic resonance imaging (MRI) allows three-dimensional velocity encoding to measure blood flow in a single scan, regardless of the intracranial artery direction. We compared blood flow velocity quantification by non-contrast 4D flow MRI and by transcranial Doppler ultrasound (TCD), the most widely used modality for measuring velocity. Twenty-two patients underwent both TCD and non-contrast 4D flow MRI. The mean time interval between TCD and non-contrast 4D flow MRI was 0.7 days. Subsegmental velocities were measured bilaterally in the middle cerebral and basilar arteries using TCD and non-contrast 4D flow MRI. Intracranial velocity measurements using TCD and non-contrast 4D flow MRI demonstrated a strong correlation in the bilateral M1, especially at the proximal segment (right r = 0.74, left r = 0.78; all p < 0.001). Mean velocities acquired with 4D flow MRI were approximately 8 to 10% lower than those acquired with TCD according to the location of M1. Intracranial arterial flow measurements estimated using non-contrast 4D flow MRI and TCD showed strong correlation. 4D flow MRI enables simultaneous assessment of vascular morphology and quantitative hemodynamic measurement, providing three-dimensional blood flow visualization. 4D flow MRI is a clinically useful sequence with a promising role in cerebrovascular disease.
Collapse
Affiliation(s)
- Sam-Yeol Ha
- Department of Neurology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Korea; (S.-Y.H.); (S.P.)
- Department of Neurology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Korea
| | - Yeonah Kang
- Department of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Korea; (H.-J.L.); (J.B.)
- Correspondence: ; Tel.: +82-51-797-0340; Fax: +82-51-797-0379
| | - Ho-Joon Lee
- Department of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Korea; (H.-J.L.); (J.B.)
| | | | - Jiyeon Baik
- Department of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Korea; (H.-J.L.); (J.B.)
- Department of Radiology, Good Gang-An Hospital, Busan 48265, Korea
| | - Seongho Park
- Department of Neurology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Korea; (S.-Y.H.); (S.P.)
| |
Collapse
|
14
|
Ngo MT, Lee UY, Ha H, Jung J, Lee DH, Kwak HS. Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP. Diagnostics (Basel) 2021; 11:diagnostics11101890. [PMID: 34679588 PMCID: PMC8534781 DOI: 10.3390/diagnostics11101890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/06/2021] [Accepted: 10/10/2021] [Indexed: 11/16/2022] Open
Abstract
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.
Collapse
Affiliation(s)
- Minh Tri Ngo
- Department of Radiology of Hue Central Hospital, Hue, Thua Thien Hue 530000, Vietnam;
| | - Ui Yun Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea;
| | - Jinmu Jung
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
| | - Dong Hwan Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| | - Hyo Sung Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| |
Collapse
|
15
|
Blanken CPS, Gottwald LM, Westenberg JJM, Peper ES, Coolen BF, Strijkers GJ, Nederveen AJ, Planken RN, van Ooij P. Whole-Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo-Spiral Sampling and EPI Readout. J Magn Reson Imaging 2021; 55:1120-1130. [PMID: 34510612 PMCID: PMC9290924 DOI: 10.1002/jmri.27905] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/18/2021] [Accepted: 08/19/2021] [Indexed: 01/23/2023] Open
Abstract
Background Pseudo‐spiral Cartesian sampling with compressed sensing reconstruction has facilitated highly accelerated 4D flow magnetic resonance imaging (MRI) in various cardiovascular structures. However, unlike echo planar imaging (EPI)‐accelerated 4D flow MRI, it has not been validated in whole‐heart applications. Hypothesis Pseudo‐spiral 4D flow MRI (PROUD [PROspective Undersampling in multiple Dimensions]) is comparable to EPI in robustness of valvular flow measurements and remains comparable as the undersampling factor is increased and scan time reduced. Study Type Prospective. Population Twelve healthy subjects and eight patients with valvular regurgitation. Field Strength/Sequence 3.0 T; PROUD and EPI 4D flow sequences, 2D flow and balanced steady‐state free precession sequences. Assessment Valvular blood flow was quantified using valve tracking. PROUD‐ and EPI‐based measurements of aortic (AV) and pulmonary (PV) flow volumes and left and right ventricular stroke volumes were tested for agreement with 2D MRI‐based measurements. PROUD reconstructions with undersampling factors (R) of 9, 14, 28, and 56 were tested for intervalve consistency (per valve, compared to the other valves) and preservation of peak velocities and E/A ratios. Statistical Tests We used repeated measures ANOVA, Bland‐Altman, Wilcoxon signed rank, and intraclass correlation coefficients. P < 0.05 was considered statistically significant. Results PROUD and EPI intervalve consistencies were not significantly different both in healthy subjects (valve‐averaged mean difference [limits of agreement width]: 3.2 ± 0.8 [8.7 ± 1.1] mL/beat for PROUD, 5.5 ± 2.9 [13.7 ± 2.3] mL/beat for EPI, P = 0.07) and in patients with valvular regurgitation (2.3 ± 1.2 [15.3 ± 5.9] mL/beat for PROUD, 0.6 ± 0.6 [19.3 ± 2.9] mL/beat for EPI, P = 0.47). Agreement between EPI and PROUD was higher than between 4D flow (EPI or PROUD) and 2D MRI for forward flow, stroke volumes, and regurgitant volumes. Up to R = 28 in healthy subjects and R = 14 in patients with valvular regurgitation, PROUD intervalve consistency remained comparable to that of EPI. Peak velocities and E/A ratios were preserved up to R = 9. Conclusion PROUD is comparable to EPI in terms of intervalve consistency and may be used with higher undersampling factors to shorten scan times further. Level of Evidence 1 Technical Efficacy Stage 2
Collapse
Affiliation(s)
- Carmen P S Blanken
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - Lukas M Gottwald
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | | | - Eva S Peper
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - Bram F Coolen
- Department of Biomedical Engineering and Physics, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - Gustav J Strijkers
- Department of Biomedical Engineering and Physics, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - R Nils Planken
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands
| |
Collapse
|
16
|
Gunn AJ, Kalva SP, Majdalany BS, Craft J, Eldrup-Jorgensen J, Ferencik M, Ganguli S, Kendi AT, Khaja MS, Obara P, Russell RR, Sutphin PD, Vijay K, Wang DS, Dill KE. ACR Appropriateness Criteria® Nontraumatic Aortic Disease. J Am Coll Radiol 2021; 18:S106-S118. [PMID: 33958105 DOI: 10.1016/j.jacr.2021.02.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 02/08/2021] [Indexed: 01/16/2023]
Abstract
Nontraumatic aortic disease can be caused by a wide variety of disorders including congenital, inflammatory, infectious, metabolic, neoplastic, and degenerative processes. Imaging examinations such as radiography, ultrasound, echocardiography, catheter-based angiography, CT, MRI, and nuclear medicine examinations are essential for diagnosis, treatment planning, and assessment of therapeutic response. Depending upon the clinical scenario, each of these modalities has strengths and weaknesses. Whenever possible, the selection of a diagnostic imaging examination should be based upon the best available evidence. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. The purpose of this document is to assist physicians select the most appropriate diagnostic imaging examination for nontraumatic aortic diseases.
Collapse
Affiliation(s)
- Andrew J Gunn
- University of Alabama at Birmingham, Birmingham, Alabama, Director, Interventional Oncology, Director, Ambulatory Clinic, Assistant Program Director, Diagnostic Radiology Residency, Assistant Program Director, Interventional Radiology Residency, University of Alabama at Birmingham, Member, American College of Radiology-Radiologic Society of North America Patient Information Committee.
| | - Sanjeeva P Kalva
- Panel Chair, Massachusetts General Hospital, Boston, Massachusetts, Chief, Division of Interventional Radiology, Massachusetts General Hospital
| | | | - Jason Craft
- St. Francis Hospital, Catholic Health Services of Long Island, Roslyn, New York, Society for Cardiovascular Magnetic Resonance
| | - Jens Eldrup-Jorgensen
- Tufts University School of Medicine, Boston, Massachusetts, Society for Vascular Surgery
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, Society of Cardiovascular Computed Tomography
| | | | - A Tuba Kendi
- Mayo Clinic, Rochester, Minnesota, Director of Nuclear Medicine Therapies at Mayo Clinic Rochester
| | - Minhajuddin S Khaja
- University of Virginia, Charlottesville, Virginia, Vice-Chair ACR Vascular Imaging Panel 2, Program Director, Independent IR Residency, UVA Health
| | - Piotr Obara
- Loyola University Medical Center, Maywood, Illinois
| | - Raymond R Russell
- The Warren Alpert School of Medicine at Brown University, Providence, Rhode Island, Nuclear cardiology expert, Program Director, Cardiology Fellowship, Director, Nuclear Cardiology, Director, Cardio-Oncology Program, Rhode Island Hospital
| | | | | | - David S Wang
- Stanford University Medical Center, Stanford, California
| | - Karin E Dill
- Specialty Chair, Emory University Hospital, Atlanta, Georgia
| |
Collapse
|
17
|
Ngo MT, Lee UY, Ha H, Jin N, Chung GH, Kwak YG, Jung J, Kwak HS. Comparison of Hemodynamic Visualization in Cerebral Arteries: Can Magnetic Resonance Imaging Replace Computational Fluid Dynamics? J Pers Med 2021; 11:jpm11040253. [PMID: 33808514 PMCID: PMC8066205 DOI: 10.3390/jpm11040253] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 03/23/2021] [Accepted: 03/27/2021] [Indexed: 01/04/2023] Open
Abstract
A multimodality approach was applied using four-dimensional flow magnetic resonance imaging (4D flow MRI), time-of-flight magnetic resonance angiography (TOF-MRA) signal intensity gradient (SIG), and computational fluid dynamics (CFD) to investigate the 3D blood flow characteristics and wall shear stress (WSS) of the cerebral arteries. TOF-MRA and 4D flow MRI were performed on the major cerebral arteries in 16 healthy volunteers (mean age 34.7 ± 7.6 years). The flow rate measured with 4D flow MRI in the internal carotid artery, middle cerebral artery, and anterior cerebral artery were 3.8, 2.5, and 1.2 mL/s, respectively. The 3D blood flow pattern obtained through CFD and 4D flow MRI on the cerebral arteries showed reasonable consensus. CFD delivered much greater resolution than 4D flow MRI. TOF-MRA SIG and CFD WSS of the major cerebral arteries showed reasonable consensus with the locations where the WSS was relatively high. However, the visualizations were very different between TOF-MRA SIG and CFD WSS at the internal carotid artery bifurcations, the anterior cerebral arteries, and the anterior communicating arteries. 4D flow MRI, TOF-MRA SIG, and CFD are complementary methods that can provide additional insight into the hemodynamics of the human cerebral artery.
Collapse
Affiliation(s)
- Minh Tri Ngo
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea; (M.T.N.); (G.H.C.); (Y.G.K.)
| | - Ui Yun Lee
- Division of Mechanical Design Engineering, Jeonbuk National University, Jeon-ju 54896, Korea;
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea;
| | - Ning Jin
- Siemens Medical Solutions USA, Inc., Chicago, IL 60089, USA;
| | - Gyung Ho Chung
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea; (M.T.N.); (G.H.C.); (Y.G.K.)
| | - Yeong Gon Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea; (M.T.N.); (G.H.C.); (Y.G.K.)
| | - Jinmu Jung
- Division of Mechanical Design Engineering, Jeonbuk National University, Jeon-ju 54896, Korea;
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
- Correspondence: (J.J.); (H.S.K.); Tel.: +82-63-270-3998 (J.J.); +82-63-250-2582 (H.S.K.)
| | - Hyo Sung Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea; (M.T.N.); (G.H.C.); (Y.G.K.)
- Correspondence: (J.J.); (H.S.K.); Tel.: +82-63-270-3998 (J.J.); +82-63-250-2582 (H.S.K.)
| |
Collapse
|
18
|
Choe YH, Kim SM, Park SJ. Computed tomography and magnetic resonance imaging assessment of aortic valve stenosis: an update. PRECISION AND FUTURE MEDICINE 2020. [DOI: 10.23838/pfm.2020.00093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
19
|
Fathi MF, Perez-Raya I, Baghaie A, Berg P, Janiga G, Arzani A, D'Souza RM. Super-resolution and denoising of 4D-Flow MRI using physics-Informed deep neural nets. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105729. [PMID: 33007592 DOI: 10.1016/j.cmpb.2020.105729] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 08/23/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE Time resolved three-dimensional phase contrast magnetic resonance imaging (4D-Flow MRI) has been used to non-invasively measure blood velocities in the human vascular system. However, issues such as low spatio-temporal resolution, acquisition noise, velocity aliasing, and phase-offset artifacts have hampered its clinical application. In this research, we developed a purely data-driven method for super-resolution and denoising of 4D-Flow MRI. METHODS The flow velocities, pressure, and the MRI image magnitude are modeled as a patient-specific deep neural net (DNN). For training, 4D-Flow MRI images in the complex Cartesian space are used to impose data-fidelity. Physics of fluid flow is imposed through regularization. Creative loss function terms have been introduced to handle noise and super-resolution. The trained patient-specific DNN can be sampled to generate noise-free high-resolution flow images. The proposed method has been implemented using the TensorFlow DNN library and tested on numerical phantoms and validated in-vitro using high-resolution particle image velocitmetry (PIV) and 4D-Flow MRI experiments on transparent models subjected to pulsatile flow conditions. RESULTS In case of numerical phantoms, we were able to increase spatial resolution by a factor of 100 and temporal resolution by a factor of 5 compared to the simulated 4D-Flow MRI. There is an order of magnitude reduction of velocity normalized root mean square error (vNRMSE). In case of the in-vitro validation tests with PIV as reference, there is similar improvement in spatio-temporal resolution. Although the vNRMSE is reduced by 50%, the method is unable to negate a systematic bias with respect to the reference PIV that is introduced by the 4D-Flow MRI measurement. CONCLUSIONS This work has demonstrated the feasibility of using the readily available machinery of deep learning to enhance 4D-Flow MRI using a purely data-driven method. Unlike current state-of-the-art methods, the proposed method is agnostic to geometry and boundary conditions and therefore eliminates the need for tedious tasks such as accurate image segmentation for geometry, image registration, and estimation of boundary flow conditions. Arbitrary regions of interest can be selected for processing. This work will lead to user-friendly analysis tools that will enable quantitative hemodynamic analysis of vascular diseases in a clinical setting.
Collapse
Affiliation(s)
- Mojtaba F Fathi
- Dept. of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
| | - Isaac Perez-Raya
- Dept. of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
| | - Ahmadreza Baghaie
- Dept. of Electrical and Computer Engineering, New York Institute of Technology, Long Island, NY, USA
| | - Philipp Berg
- Lab. of Fluid Dynamics and Technical Flows, University of Magdeburg, Germany; Research Campus STIMULATE, University of Magdeburg, Magdeburg, Germany
| | - Gabor Janiga
- Lab. of Fluid Dynamics and Technical Flows, University of Magdeburg, Germany; Research Campus STIMULATE, University of Magdeburg, Magdeburg, Germany
| | - Amirhossein Arzani
- Dept. of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ, USA
| | - Roshan M D'Souza
- Dept. of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA.
| |
Collapse
|
20
|
Abstract
Hintergrund Durch die Entwicklung robuster Techniken und deren umfassender Validierung hat sich die kardiale Magnetresonanztomographie (CMR) in ihrem knapp 25-jährigen klinischen Einsatz ein breites Indikationsspektrum erarbeitet. Die Erfassung kardialer Volumina und systolischer Ventrikelfunktion sowie die Charakterisierung fokaler Myokardnarben sind heute Teil der CMR-Standard-Bildgebung. Zuletzt haben die Einführung beschleunigter Bildakquisitionstechnologien, die neuen Bildgebungsmethoden des myokardialen T1- und T2-Mappings und der 4‑D-Flussmessungen sowie die neue Postprocessing-Technik des myokardialen Feature-Trackings an Relevanz gewonnen. Methode Diese Überblicksarbeit basiert auf einer umfassenden Literaturrecherche in der PubMed-Datenbank zu neuen CMR-Techniken und ihrer klinischen Anwendung. Ergebnisse und Schlussfolgerung Dieser Artikel zeigt eine Übersicht über die neuesten technischen Entwicklungen im Bereich der CMR sowie deren Anwendungsmöglichkeiten anhand der wichtigsten klinischen Fragestellungen.
Collapse
Affiliation(s)
- A Mayr
- Universitätsklinik für Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - G Reiter
- Research and Development, Siemens Healthcare Diagnostics GmbH, Straßgangerstraße 315, 8054, Graz, Österreich
| | - D Beitzke
- Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Währinger Gürtel 18-20, 1090, Wien, Österreich.
| |
Collapse
|
21
|
Concannon J, Hynes N, McMullen M, Smyth E, Moerman K, McHugh PE, Sultan S, Karmonik C, McGarry JP. A Dual-VENC Four-Dimensional Flow MRI Framework for Analysis of Subject-Specific Heterogeneous Nonlinear Vessel Deformation. J Biomech Eng 2020; 142:1087598. [DOI: 10.1115/1.4048649] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Indexed: 12/19/2022]
Abstract
Abstract
Advancement of subject-specific in silico medicine requires new imaging protocols tailored to specific anatomical features, paired with new constitutive model development based on structure/function relationships. In this study, we develop a new dual-velocity encoding coefficient (VENC) 4D flow MRI protocol that provides unprecedented spatial and temporal resolution of in vivo aortic deformation. All previous dual-VENC 4D flow MRI studies in the literature focus on an isolated segment of the aorta, which fail to capture the full spectrum of aortic heterogeneity that exists along the vessel length. The imaging protocol developed provides high sensitivity to all blood flow velocities throughout the entire cardiac cycle, overcoming the challenge of accurately measuring the highly unsteady nonuniform flow field in the aorta. Cross-sectional area change, volumetric flow rate, and compliance are observed to decrease with distance from the heart, while pulse wave velocity (PWV) is observed to increase. A nonlinear aortic lumen pressure–area relationship is observed throughout the aorta such that a high vessel compliance occurs during diastole, and a low vessel compliance occurs during systole. This suggests that a single value of compliance may not accurately represent vessel behavior during a cardiac cycle in vivo. This high-resolution MRI data provide key information on the spatial variation in nonlinear aortic compliance, which can significantly advance the state-of-the-art of in-silico diagnostic techniques for the human aorta.
Collapse
Affiliation(s)
- J. Concannon
- Biomedical Engineering, National University of Ireland Galway, Galway H91 TK33, Ireland
| | - N. Hynes
- Department of Vascular and Endovascular Surgery, National University of Ireland Galway, Galway H91 TK33, Ireland
| | - M. McMullen
- Department of Radiology, Galway Clinic, Doughiska, Galway H91 HHT0, Ireland
| | - E. Smyth
- Department of Radiology, Galway Clinic, Doughiska, Galway H91 HHT0, Ireland
| | - K. Moerman
- Biomedical Engineering, National University of Ireland Galway, Galway H91 TK33, Ireland
| | - P. E. McHugh
- Biomedical Engineering, National University of Ireland Galway, Galway H91 TK33, Ireland
| | - S. Sultan
- Department of Vascular and Endovascular Surgery, National University of Ireland Galway, Galway H91 TK33, Ireland
| | - C. Karmonik
- MRI Core, Houston Methodist Debakey Heart and Vascular Center, Houston, TX 77030
| | - J. P. McGarry
- Biomedical Engineering, National University of Ireland Galway, Galway H91 TK33, Ireland
| |
Collapse
|
22
|
Catapano F, Pambianchi G, Cundari G, Rebelo J, Cilia F, Carbone I, Catalano C, Francone M, Galea N. 4D flow imaging of the thoracic aorta: is there an added clinical value? Cardiovasc Diagn Ther 2020; 10:1068-1089. [PMID: 32968661 DOI: 10.21037/cdt-20-452] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Four-dimensional (4D) flow MRI has emerged as a powerful non-invasive technique in cardiovascular imaging, enabling to analyse in vivo complex flow dynamics models by quantifying flow parameters and derived features. Deep knowledge of aortic flow dynamics is fundamental to better understand how abnormal flow patterns may promote or worsen vascular diseases. In the perspective of an increasingly personalized and preventive medicine, growing interest is focused on identifying those quantitative functional features which are early predictive markers of pathological evolution. The thoracic aorta and its spectrum of diseases, as the first area of application and development of 4D flow MRI and supported by an extensive experimental validation, represents the ideal model to introduce this technique into daily clinical practice. The purpose of this review is to describe the impact of 4D flow MRI in the assessment of the thoracic aorta and its most common affecting diseases, providing an overview of the actual clinical applications and describing the potential role of derived advanced hemodynamic measures in tailoring follow-up and treatment.
Collapse
Affiliation(s)
- Federica Catapano
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Giacomo Pambianchi
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Giulia Cundari
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - João Rebelo
- Department of Radiology, Centro Hospitalar São João, Alameda Prof. Hernâni Monteiro, Porto, Portugal
| | - Francesco Cilia
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Iacopo Carbone
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Carlo Catalano
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Marco Francone
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy
| | - Nicola Galea
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, Rome, Italy.,Department of Experimental Medicine, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
23
|
Edlin J, Youssefi P, Bilkhu R, Figueroa CA, Morgan R, Nowell J, Jahangiri M. Haemodynamic assessment of bicuspid aortic valve aortopathy: a systematic review of the current literature. Eur J Cardiothorac Surg 2020; 55:610-617. [PMID: 30239633 DOI: 10.1093/ejcts/ezy312] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 08/09/2018] [Accepted: 08/15/2018] [Indexed: 11/12/2022] Open
Abstract
Both genetic and haemodynamic theories explain the aetiology, progression and optimal management of bicuspid aortic valve aortopathy. In recent years, the haemodynamic theory has been explored with the help of magnetic resonance imaging and computational fluid dynamics. The objective of this review was to summarize the findings of these investigations with focus on the blood flow pattern and associated variables, including flow eccentricity, helicity, flow displacement, cusp opening angle, systolic flow angle, wall shear stress (WSS) and oscillatory shear index. A structured literature review was performed from January 1990 to January 2018 and revealed the following 3 main findings: (i) the bicuspid aortic valve is associated with flow eccentricity and helicity in the ascending aorta compared to healthy and diseased tricuspid aortic valve, (ii) flow displacement is easier to obtain than WSS and has been shown to correlate with valve morphology and type of aortopathy and (iii) the stenotic bicuspid aortic valve is associated with elevated WSS along the greater curvature of the ascending aorta, where aortic dilatation and aortic wall thinning are commonly found. We conclude that new haemodynamic variables should complement ascending aorta diameter as an indicator for disease progression and the type and timing of intervention. WSS describes the force that blood flow exerts on the vessel wall as a function of viscosity and geometry of the vessel, making it a potentially more reliable marker of disease progression.
Collapse
Affiliation(s)
- Joy Edlin
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Pouya Youssefi
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Rajdeep Bilkhu
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Carlos Alberto Figueroa
- Department of Biomedical Engineering, King's College London, London, UK.,Department of Surgery, University of Michigan, Ann Arbor, MI, USA
| | - Robert Morgan
- Department of Radiology, St George's Hospital, London, UK
| | - Justin Nowell
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Marjan Jahangiri
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| |
Collapse
|
24
|
Age and anatomical location related hemodynamic changes assessed by 4D flow MRI in the carotid arteries of healthy adults. Eur J Radiol 2020; 128:109035. [DOI: 10.1016/j.ejrad.2020.109035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 04/14/2020] [Accepted: 04/26/2020] [Indexed: 01/01/2023]
|
25
|
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics. Diagnostics (Basel) 2019; 9:diagnostics9040223. [PMID: 31847224 PMCID: PMC6963916 DOI: 10.3390/diagnostics9040223] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 11/22/2019] [Accepted: 12/12/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose: Knowledge of the hemodynamics in the vascular system is important to understand and treat vascular pathology. The present study aimed to evaluate the hemodynamics in the human carotid artery bifurcation measured by four-dimensional (4D) flow magnetic resonance imaging (MRI) as compared to computational fluid dynamics (CFD). Methods: This protocol used MRI data of 12 healthy volunteers for the 3D vascular models and 4D flow MRI measurements for the boundary conditions in CFD simulation. We compared the velocities measured at the carotid bifurcation and the 3D velocity streamlines of the carotid arteries obtained by these two methods. Results: There was a good agreement for both maximum and minimum velocity values between the 2 methods for velocity magnitude at the bifurcation plane. However, on the 3D blood flow visualization, secondary flows, and recirculation regions are of poorer quality when visualized through the 4D flow MRI. Conclusion: 4D flow MRI and CFD show reasonable agreement in demonstrated velocity magnitudes at the carotid artery bifurcation. However, the visualization of blood flow at the recirculation regions and the assessment of secondary flow characteristics should be enhanced for the use of 4D flow MRI in clinical situations.
Collapse
|
26
|
Genkel VV, Kuznetcova AS, Shaposhnik II. Biomechanical Forces and Atherosclerosis: From Mechanism to Diagnosis and Treatment. Curr Cardiol Rev 2019; 16:187-197. [PMID: 31362692 PMCID: PMC7536809 DOI: 10.2174/1573403x15666190730095153] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 07/16/2019] [Accepted: 07/17/2019] [Indexed: 11/22/2022] Open
Abstract
The article provides an overview of current views on the role of biomechanical forces in the pathogenesis of atherosclerosis. The importance of biomechanical forces in maintaining vascular homeostasis is considered. We provide descriptions of mechanosensing and mechanotransduction. The roles of wall shear stress and circumferential wall stress in the initiation, progression and destabilization of atherosclerotic plaque are described. The data on the possibilities of assessing biomechanical factors in clinical practice and the clinical significance of this approach are presented. The article concludes with a discussion on current therapeutic approaches based on the modulation of biomechanical forces.
Collapse
Affiliation(s)
- Vadim V Genkel
- Department of Internal Medicine, Federal State Budgetary Educational Institution of Higher Education "South-Ural State Medical University" of the Ministry of Healthcare of the Russian Federation, Chelyabinsk, Russian Federation
| | - Alla S Kuznetcova
- Department of Hospital Therapy Federal State Budgetary Educational Institution of Higher Education "South-Ural State Medical University" of the Ministry of Healthcare of the Russian Federation, Chelyabinsk, Russian Federation
| | - Igor I Shaposhnik
- Department of Internal Medicine, Federal State Budgetary Educational Institution of Higher Education "South-Ural State Medical University" of the Ministry of Healthcare of the Russian Federation, Chelyabinsk, Russian Federation
| |
Collapse
|
27
|
Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations. J Biomech 2019; 94:13-21. [PMID: 31326119 DOI: 10.1016/j.jbiomech.2019.07.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 06/12/2019] [Accepted: 07/04/2019] [Indexed: 12/20/2022]
Abstract
Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- and time-resolved magnetic resonance imaging (4D flow) data. Yet the limitations of this imaging technique require testing the accuracy of 4D flow-derived hemodynamic quantities against other methodologies. With the objective of assessing the feasibility and accuracy of this non-invasive method to support the clinical diagnosis of CoA, we developed an algorithm (4DF-FEPPE) to obtain relative pressure distributions from 4D flow data by solving the Poisson pressure equation. 4DF-FEPPE was tested against results from a patient-specific fluid-structure interaction (FSI) simulation, whose patient-specific boundary conditions were prescribed based on 4D flow data. Since numerical simulations provide noise-free pressure fields on fine spatial and temporal scales, our analysis allowed to assess the uncertainties related to 4D flow noise and limited resolution. 4DF-FEPPE and FSI results were compared on a series of cross-sections along the aorta. Bland-Altman analysis revealed very good agreement between the two methodologies in terms of instantaneous data at peak systole, end-diastole and time-averaged values: biases (means of differences) were +0.4 mmHg, -1.1 mmHg and +0.6 mmHg, respectively. Limits of agreement (2 SD) were ±0.978 mmHg, ±1.06 mmHg and ±1.97 mmHg, respectively. Peak-to-peak and maximum trans-coarctation pressure drops obtained with 4DF-FEPPE differed from FSI results by 0.75 mmHg and -1.34 mmHg respectively. The present study considers important validation aspects of non-invasive pressure difference estimation based on 4D flow MRI, showing the potential of this technology to be more broadly applied to the clinical practice.
Collapse
|
28
|
Hong H, Song JM, Yeom E. Variations in pulsatile flow around stenosed microchannel depending on viscosity. PLoS One 2019; 14:e0210993. [PMID: 30677055 PMCID: PMC6345426 DOI: 10.1371/journal.pone.0210993] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 01/04/2019] [Indexed: 12/17/2022] Open
Abstract
In studying blood flow in the vessels, the characteristics of non-Newtonian fluid are important, considering the role of viscosity in rheology. Stenosis, which is an abnormal narrowing of the vessel, has an influence on flow behavior. Therefore, analysis of blood flow in stenosed vessels is essential. However, most of them exist as simulation outcomes. In this study, non-Newtonian fluid was observed in stenosed microchannels under the pulsatile flow condition. A polydimethylsiloxane channel with 60% stenosis was fabricated by combining an optic fiber and a petri dish, resembling a mold. Three types of samples were prepared by changing the concentrations of xanthan gum, which induces a shear thinning effect (phosphate buffered saline (PBS) solution as the Newtonian fluid and two non-Newtonian fluids mimicking normal blood and highly viscous blood analog). The viscosity of the samples was measured using a Y-shaped microfluidic viscometer. Thereafter, velocity profiles were analyzed under the pulsatile flow condition using the micro-particle image velocimetry (PIV) method. For the Newtonian fluid, the streamline was skewed more to the wall of the channel. The velocity profile of the non-Newtonian fluid was generally blunter than that of the Newtonian fluid. A highly oscillating wall shear stress (WSS) during the pulsatile phase may be attributed to such a bluntness of flow under the same wall shear rate condition with the Newtonian fluid. In addition, a highly viscous flow contributes to the variation in the WSS after passing through the stenosed structures. A similar tendency was observed in simulation results. Such a variation in the WSS was associated with plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.
Collapse
Affiliation(s)
- Hyeonji Hong
- School of Mechanical Engineering, Pusan National University, Busan, South Korea
| | - Jae Min Song
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Busan, South Korea
| | - Eunseop Yeom
- School of Mechanical Engineering, Pusan National University, Busan, South Korea
- * E-mail:
| |
Collapse
|
29
|
The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric. Ann Biomed Eng 2017; 46:404-416. [PMID: 29094292 DOI: 10.1007/s10439-017-1950-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 10/20/2017] [Indexed: 12/12/2022]
Abstract
Flow efficiency through the Fontan connection is an important factor related to patient outcomes. It can be quantified using either a simplified power loss or a viscous dissipation rate metric. Though practically equivalent in simplified Fontan circulation models, these metrics are not identical. Investigation is needed to evaluate the advantages and disadvantages of these metrics for their use in in vivo or more physiologically-accurate Fontan modeling. Thus, simplified power loss and viscous dissipation rate are compared theoretically, computationally, and statistically in this study. Theoretical analysis was employed to assess the assumptions made for each metric and its clinical calculability. Computational simulations were then performed to obtain these two metrics. The results showed that apparent simplified power loss was always greater than the viscous dissipation rate for each patient. This discrepancy can be attributed to the assumptions derived in theoretical analysis. Their effects were also deliberately quantified in this study. Furthermore, statistical analysis was conducted to assess the correlation between the two metrics. Viscous dissipation rate and its indexed quantity show significant, strong, linear correlation to simplified power loss and its indexed quantity (p < 0.001, r > 0.99) under certain assumptions. In conclusion, viscous dissipation rate was found to be more advantageous than simplified power loss as a hemodynamic metric because of its lack of limiting assumptions and calculability in the clinic. Moreover, in addition to providing a time-averaged bulk measurement like simplified power loss, viscous dissipation rate has spatial distribution contours and time-resolved values that may provide additional clinical insight. Finally, viscous dissipation rate could maintain the relationship between Fontan connection flow efficiency and patient outcomes found in previous studies. Consequently, future Fontan hemodynamic studies should calculate both simplified power loss and viscous dissipation rate to maintain ties to previous studies, but also provide the most accurate measure of flow efficiency. Additional attention should be paid to the assumptions required for each metric.
Collapse
|
30
|
|