Kling S, Frigelli M, Aydemir ME, Tahsini V, Torres-Netto EA, Kollros L, Hafezi F. Optical coherence tomography quantifies gradient refractive index and mechanical stiffness gradient across the human lens. COMMUNICATIONS MEDICINE 2024; 4:162. [PMID: 39134623 PMCID: PMC11319654 DOI: 10.1038/s43856-024-00578-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 07/18/2024] [Indexed: 08/15/2024] Open
Abstract
BACKGROUND As a key element of ocular accommodation, the inherent mechanical stiffness gradient and the gradient refractive index (GRIN) of the crystalline lens determine its deformability and optical functionality. Quantifying the GRIN profile and deformation characteristics in the lens has the potential to improve the diagnosis and follow-up of lenticular disorders and guide refractive interventions in the future. METHODS Here, we present a type of optical coherence elastography able to examine the mechanical characteristics of the human crystalline lens and the GRIN distribution in vivo. The concept is demonstrated in a case series of 12 persons through lens displacement and strain measurements in an age-mixed group of human subjects in response to an external (ambient pressure modulation) and an intrinsic (micro-fluctuations of accommodation) mechanical deformation stimulus. RESULTS Here we show an excellent agreement between the high-resolution strain map retrieved during steady-state micro-fluctuations and earlier reports on lens stiffness in the cortex and nucleus suggesting a 2.0 to 2.3 times stiffer cortex than the nucleus in young lenses and a 1.0 to 7.0 times stiffer nucleus than the cortex in the old lenses. CONCLUSIONS Optical coherence tomography is suitable to quantify the internal stiffness and refractive index distribution of the crystalline lens in vivo and thus might contribute to reveal its inner working mechanism. Our methodology provides new routes for ophthalmic pre-surgical examinations and basic research.
Collapse
Affiliation(s)
- Sabine Kling
- Institute for Biomedical Engineering, ITET Department, ETH Zurich, Zurich, Switzerland.
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
| | - Matteo Frigelli
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | | | - Vahoora Tahsini
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Emilio A Torres-Netto
- ELZA Institute AG, Dietikon, Switzerland
- CABMM, University of Zurich, Zurich, Switzerland
- Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | | | - Farhad Hafezi
- ELZA Institute AG, Dietikon, Switzerland
- CABMM, University of Zurich, Zurich, Switzerland
- Faculty of Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
2
|
Frigelli M, Büchler P, Kling S. Dynamic evaluation of corneal cross-linking and osmotic diffusion effects using optical coherence elastography. Sci Rep 2024; 14:16614. [PMID: 39025900 PMCID: PMC11258322 DOI: 10.1038/s41598-024-67278-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 07/09/2024] [Indexed: 07/20/2024] Open
Abstract
Dynamic deformation events induced by osmosis or photochemical stiffening substantially influence geometrical and mechanical assessments in post-mortem corneas, therefore need to be carefully monitored in experimental settings. In this study, we employed optical coherence elastography (OCE) to quantify dynamic deformation processes at high resolution in freshly enucleated porcine corneas. Osmotic effects were studied by immerging n = 9 eyes in preservation media of three different tonicities. Dynamic processes underlying corneal cross-linking (CXL) were studied by subjecting n = 6 eyes to standard Dresden treatment, while three control groups were used. The entire procedures were performed under an OCE setup during up to 80 min, acquiring a volumetric scan every 20 s. Changes in OCE-derived axial deformations were incrementally calculated between consecutive scans. Preservation conditions had a strong influence on the observed strain patterns, which were consistent with the tonicity of the medium (swelling in hypotonic, deswelling in hypertonic environment). In the CXL group, we observed deswelling of the anterior stroma 10 min after starting the UV irradiation, which was not observed in any control group (p = 0.007). The presented results proved OCE to be a valuable technique to quantify subtle dynamic biomechanical alterations in the cornea resulting from CXL and preservation solutions.
Collapse
Affiliation(s)
- Matteo Frigelli
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Philippe Büchler
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Sabine Kling
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
| |
Collapse
|
3
|
Nambiar MH, Seiler TG, Senti S, Liechti L, Müller F, Studer H, Roy AS, Büchler P. Depth-dependent mechanical properties of the human cornea by uniaxial extension. Exp Eye Res 2023; 237:109718. [PMID: 37952725 DOI: 10.1016/j.exer.2023.109718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 10/13/2023] [Accepted: 11/06/2023] [Indexed: 11/14/2023]
Abstract
The purpose of this study was to investigate the depth-dependent biomechanical properties of the human corneal stroma under uniaxial tensile loading. Human stroma samples were obtained after the removal of Descemet's membrane in the course of Descemet's membrane endothelial keratoplasty (DMEK) transplantation. Uniaxial tensile tests were performed at three different depths: anterior, central, and posterior on 2 × 6 × 0.15 mm strips taken from the central DMEK graft. The measured force-displacement data were used to calculate stress-strain curves and to derive the tangent modulus. The study showed that mechanical strength decreased significantly with depth. The anterior cornea appeared to be the stiffest, with a stiffness approximately 18% higher than that of the central cornea and approximately 38% higher than that of the posterior layer. Larger variations in mechanical response were observed in the posterior group, probably due to the higher degree of alignment of the collagen fibers in the posterior sections of the cornea. This study contributes to a better understanding of the biomechanical tensile properties of the cornea, which has important implications for the development of new treatment strategies for corneal diseases. Accurate quantification of tensile strength as a function of depth is critical information that is lacking in human corneal biomechanics to develop numerical models and new treatment methods.
Collapse
Affiliation(s)
- Malavika H Nambiar
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.
| | - Theo G Seiler
- IROC AG, Institut für Refraktive und Ophthalmo-Chirurgie, Stockerstrasse 37, 8002, Zürich, Switzerland; Universitätsklinik für Augenheilkunde, Inselspital Bern, Freiburgstrasse 15, 3010, Bern, Switzerland; Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Moorenstr, 540225, Düsseldorf, Germany.
| | - Sebastian Senti
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.
| | - Layko Liechti
- Ziemer Ophthalmic Systems AG, Allmendstrasse 11, 2562, Port, Switzerland.
| | - Fabian Müller
- Ziemer Ophthalmic Systems AG, Allmendstrasse 11, 2562, Port, Switzerland.
| | - Harald Studer
- Optimo Medical, Robert-Walser-Platz 7, 2503, Biel, Switzerland.
| | - Abhijit S Roy
- Narayana Nethralaya Eye Clinic, Bengaluru, Karnataka, 560010, India.
| | - Philippe Büchler
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.
| |
Collapse
|
4
|
Wang C, Zhu J, Ma J, Meng X, Ma Z, Fan F. Optical coherence elastography and its applications for the biomechanical characterization of tissues. JOURNAL OF BIOPHOTONICS 2023; 16:e202300292. [PMID: 37774137 DOI: 10.1002/jbio.202300292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 09/19/2023] [Accepted: 09/27/2023] [Indexed: 10/01/2023]
Abstract
The biomechanical characterization of the tissues provides significant evidence for determining the pathological status and assessing the disease treatment. Incorporating elastography with optical coherence tomography (OCT), optical coherence elastography (OCE) can map the spatial elasticity distribution of biological tissue with high resolution. After the excitation with the external or inherent force, the tissue response of the deformation or vibration is detected by OCT imaging. The elastogram is assessed by stress-strain analysis, vibration amplitude measurements, and quantification of elastic wave velocities. OCE has been used for elasticity measurements in ophthalmology, endoscopy, and oncology, improving the precision of diagnosis and treatment of disease. In this article, we review the OCE methods for biomechanical characterization and summarize current OCE applications in biomedicine. The limitations and future development of OCE are also discussed during its translation to the clinic.
Collapse
Affiliation(s)
- Chongyang Wang
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | | | - Jiawei Ma
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Xiaochen Meng
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Zongqing Ma
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| | - Fan Fan
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China
| |
Collapse
|
5
|
Frigelli M, Büchler P, Kling S. Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography. Front Bioeng Biotechnol 2023; 11:1272097. [PMID: 38026898 PMCID: PMC10680454 DOI: 10.3389/fbioe.2023.1272097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/20/2023] [Indexed: 12/01/2023] Open
Abstract
Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging. Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm2), accelerated CXL (fluence of 5.4 J/cm2), and high-fluence CXL (fluence of 16.2 J/cm2). The axial strain distribution in the stroma induced by ocular inflation (Δp = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed. Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9‰ ± 1.9‰) and refractive correction (3.4 ± 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction. Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.
Collapse
Affiliation(s)
- Matteo Frigelli
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Philippe Büchler
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Sabine Kling
- Computational Bioengineering Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
- Institute for Biomedical Engineering, ITET Department, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
6
|
Cabeza Gil I, Tahsini V, Kling S. Viscoelastic properties of porcine lenses using optical coherence elastography and inverse finite element analysis. Exp Eye Res 2023:109558. [PMID: 37385534 DOI: 10.1016/j.exer.2023.109558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/02/2023] [Accepted: 06/26/2023] [Indexed: 07/01/2023]
Abstract
The mechanical properties of the crystalline lens are crucial in determining the changes in lens shape that occur during the accommodation process and are also a major factor in the development of the two most prevalent age-related diseases of the lens, presbyopia and cataracts. However, a comprehensive understanding of these properties is currently lacking. Previous methods for characterizing the mechanical properties of the lens have been limited by the amount of data that could be collected during each test and the lack of complex material modeling. These limitations were mainly caused by the lack of imaging techniques that can provide data for the entire crystalline lens and the need for more complex models to describe the non-linear behavior of the lens. To address these issues, we characterized the mechanical properties of 13 porcine lenses during an ex vivo micro-controlled-displacement compression experiment using optical coherence elastography (OCE) and inverse finite element analysis (iFEA). OCE allowed us to quantify the internal strain distribution of the lens and differentiate between the different parts of the lens, while iFEA enabled us to implement an advanced material model to characterize the viscoelasticity of the lens nucleus and the relative stiffness gradient in the lens. Our findings revealed a pronounced and rapid viscoelastic behavior in the lens nucleus (g1 = 0.39 ± 0.13, τ1 = 5.01 ± 2.31 s) and identified the lens nucleus as the stiffest region, with a stiffness 4.42 ± 1.20 times greater than the anterior cortex and 3.47 ± 0.82 times greater than the posterior cortex. However, due to the complex nature of lens properties, it may be necessary to employ multiple tests simultaneously for a more comprehensive understanding of the crystalline lens.
Collapse
Affiliation(s)
- Iulen Cabeza Gil
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Spain
| | - Vahoura Tahsini
- ARTORG Center for Biomedical Engineering Research, University of Bern, Switzerland
| | - Sabine Kling
- ARTORG Center for Biomedical Engineering Research, University of Bern, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| |
Collapse
|
7
|
Ross AKM, Schlunck G, Böhringer D, Maier P, Eberwein P, Reinhard T, Lang SJ. Characterization of the Immediate and Delayed Biomechanical Response to UV-A Crosslinking of Human Corneas. Cornea 2023; Publish Ahead of Print:00003226-990000000-00318. [PMID: 37335854 DOI: 10.1097/ico.0000000000003336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 05/26/2023] [Indexed: 06/21/2023]
Abstract
PURPOSE Keratoconus leads to visual deterioration due to irregular astigmatism and corneal thinning. Riboflavin-based corneal UV-A crosslinking (CXL) induces novel intramolecular and intermolecular links resulting in corneal tissue stiffening, thereby halting disease progression. The purpose of this study was to analyze the immediate and delayed biomechanical responses of human donor corneas to CXL. METHODS CXL was performed according to the Dresden protocol to corneas not suitable for transplantation. Biomechanical properties were subsequently monitored by measuring the Young modulus using nanoindentation. The immediate tissue response was determined after 0, 1, 15, and 30 minutes of irradiation. Delayed biomechanical effects were investigated with follow-up measurements immediately and 1, 3, and 7 days after CXL. RESULTS Young's modulus indicated a linear trend in direct response to increasing irradiation times (mean values: total 61.31 kPa [SD 25.53], 0 minutes 48.82 kPa [SD 19.73], 1 minute 53.44 kPa [SD 25.95], 15 minutes 63.56 kPa [SD 20.99], and 30 minutes 76.76 kPa [SD 24.92]). The linear mixed model for the elastic response of corneal tissue was 49.82 kPa + (0.91 kPa/min × time [minutes]); P < 0.001. The follow-up measurements showed no significant delayed changes in the Young modulus (mean values: total 55,28 kPa [SD 15.95], immediately after CXL 56,83 kPa [SD 18.74], day 1 50.28 kPa [SD 14.15], day 3 57.08 kPa [SD 14.98], and day 7 56.83 kPa [SD 15.07]). CONCLUSIONS This study suggests a linear increase of corneal Young modulus as a function of CXL timing. No significant short-term delayed biomechanical changes posttreatment were observed.
Collapse
Affiliation(s)
- Andrea K M Ross
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Günther Schlunck
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Daniel Böhringer
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Philip Maier
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | | | - Thomas Reinhard
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Stefan Johann Lang
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| |
Collapse
|
8
|
Torres-Netto EA, Hafezi F, Kling S. Intracorneal Ring Segment Implantation Results in Corneal Mechanical Strengthening Visualized With Optical Coherence Elastography. J Refract Surg 2022; 38:459-464. [PMID: 35858197 DOI: 10.3928/1081597x-20220608-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To quantify the mechanical impact of intracorneal ring segment (ICRS) implantation of different dimensions in an ex vivo eye model. METHODS A total of 30 enucleated porcine eyes were assigned to ICRS implantation (thickness: 300 µm, angle: 120°, 210°, or 325°), tunnel creation only, or virgin control groups. For mechanical evaluation, each globe was mounted on a customized holder and intraocular pressure (IOP) was increased in steps of 0.5 mm Hg from 15 to 17 mm Hg, simulating physiologic diurnal IOP fluctuations. At each step, an optical coherence tomography volume scan was recorded. Deformations between subsequent scans and the locally induced axial strains were analyzed using a vector-based phase difference method. The effective E-modulus was derived from the overall induced strain as a measure of global mechanical impact. RESULTS ICRS implantation increased the effective E-modulus from 146 and 163 kPa in virgin and tunnel-only eyes to 149, 192, and 330 kPa in eyes that received a 5-mm optical zone ICRS with 120°, 210°, and 325° arc length, respectively; and to 209 kPa in a 6-mm optical zone ICRS with 325° arc length. The most consistent effect was a shift toward positive strains in the posterior stroma by 0.1% to 0.46% (factor 1.15 to 2.15) after ICRS surgery. CONCLUSIONS ICRS implantation reduces the overall tissue strain under the load of the IOP and provokes posterior tissue relaxation. This effect is more prominent the longer the arc length and the smaller the optical zone of the ICRS is. ICRS have not only a geometrical, but also a mechanical impact on corneal tissue. This behavior might have clinical implications when ICRS implantation is performed in biomechanically weakened keratoconic corneas. [J Refract Surg. 2022;38(7):459-464.].
Collapse
|
9
|
Novel Elastography-Inspired Approach to Angiographic Visualization in Optical Coherence Tomography. PHOTONICS 2022. [DOI: 10.3390/photonics9060401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
In this paper, we present a new approach to contrast-agent-free angiographic visualization in optical coherence tomography (OCT). The proposed approach has much in common with imaging of local interframe strains in OCT-based elastography and utilizes the fact that the interframe motion of blood particles leads to discontinuity of strains within the vessel cross section. By this reasoning, we call this approach “elastography-inspired”. Here, we first elucidate the essence and main features of the elastography-inspired approach using numerical simulation of OCT data. The simulations allow one to introduce both moving scatterers imitating blood flow in vessels as well as various masking motions imitating natural motions of living “solid” tissue surrounding the vessels. Second, using real OCT signals, we present comparative results of angiographic processing using the proposed elastography-inspired approach and a realization of OCA based on high-pass filtering of temporal variability of a series of OCT B-scans. The two methods can use the same initial dataset and the high-pass filtering OCA has already been routinely applied in both animal experiments and on patients. The new elastography-inspired method has a similar computational efficiency, and it is intrinsically able to compensate spatially-inhomogeneous masking tissue motions and demonstrates high robustness with respect to motion artefacts. Thus, the new approach looks very promising for enabling wider application of OCA in both laboratory studies on animals and, most importantly, for wider clinical applications on patients.
Collapse
|
10
|
Wilson A, Jones J, Marshall J. Biomechanical Evaluation of Decellularized and Crosslinked Corneal Implants Manufactured From Porcine Corneas as a Treatment Option for Advanced Keratoconus. Front Bioeng Biotechnol 2022; 10:862969. [PMID: 35497356 PMCID: PMC9046912 DOI: 10.3389/fbioe.2022.862969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 03/14/2022] [Indexed: 01/13/2023] Open
Abstract
Currently corneal transplantation is the main treatment for late-stage keratoconus; however, transplantation procedures are accompanied by significant risk of post-surgical complications; this in addition to supply limitations imposed by a worldwide shortage of human donor corneas, has driven the development of alternative therapies. One such therapy is the use of corneal implants derived from porcine corneas (Xenia®, Gebauer Medizintechnik GmbH, Neuhausen, DE). In contrast to human donor tissue, these implants can be produced on demand and due to the processes used pose no risks for host-immune rejection. Their use has already been demonstrated clinically in patients for preventing the progression of topographic changes in keratoconus whilst improving visual acuity. The implants are derived from natural tissue and not standardised synthetic material, whilst this likely reduces the risk of issues with bio-incompatibility, there is inevitably variability in their intrinsic mechanical properties which requires investigation. Here, speckle interferometry is employed to examine the biomechanical properties, in response to physiologically representative forces, of native porcine corneal tissue prior to processing and after a proprietary 4-stage process involving decellularization, washing, compression and crosslinking. The control lenticules had an average Young’s modulus (E) of 11.11 MPa (range 8.39–13.41 MPa), following processing average E of the lenticules increased by 127% over that of the unprocessed tissue to 25.23 MPa (range 18.32–32.9 MPa). The variability in E of the lenticules increased significantly after processing suggesting variability in the propensity of the native tissue to processing. In summary, it is possible to produce thin (<90 µm) lenticules from porcine corneas with enhanced stiffness that are effective for treating late-stage keratoconus. Due to the observed variability in the responses of lenticules to processing, interferometry could be a useful technique for ensuring quality control in commercial production via biomechanical screening.
Collapse
Affiliation(s)
- Abby Wilson
- UCL Mechanical Engineering, London, United Kingdom
- Institute of Ophthalmology, UCL, London, United Kingdom
- *Correspondence: Abby Wilson,
| | - John Jones
- Laser Optical Engineering Ltd., Donington, United Kingdom
| | - John Marshall
- Institute of Ophthalmology, UCL, London, United Kingdom
| |
Collapse
|
11
|
Torres-Netto EA, Kling S. Corneal Strain Induced by Intracorneal Ring Segment Implantation Visualized With Optical Coherence Elastography. J Refract Surg 2022; 38:210-216. [PMID: 35275004 DOI: 10.3928/1081597x-20211214-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To record the axial strain field in the cornea directly after creating a stromal tunnel and implanting an intracorneal ring segment (ICRS). METHODS Freshly enucleated porcine eyes were obtained and assigned to either ICRS implantation, tunnel creation only, or virgin control groups. Immediately after manual tunnel creation and ICRS positioning, the entire eye globe was mounted on a customized holder and intraocular pressure (IOP) was adjusted to 15 mm Hg. Then, IOP was inreased to 20 mm Hg, in steps of 1 mm Hg. At each step, an optical coherence tomography volume scan was recorded. Displacements between subsequent scans were retrieved using a vector-based phase difference method. The induced corneal strain direction was determined by taking the axial gradient. In addition, corneal surface was detected and sagittal curvature maps computed. RESULTS Corneal tissue presented a localized compressive strain in the direct vicinity of the stromal tunnel, which was independent of IOP change. The central and peripheral (exterior to the ICRS) cornea demonstrated compressive strains on IOP increase, and tensile strains on IOP decrease. ICRS implantation induced an annular-shaped tensile strain at its inner border, particularly during IOP increase. The compressive strains close to the tunnel remained after ICRS implantation. Corneal curvature changes were concentrated on regions where strain was induced. CONCLUSIONS ICRS implantation induces localized strains in the regions subjected to refractive changes, suggesting that corneal strain and curvature are directly related. Studying corneal strain in response to surgical intervention may provide new insights on underlying working principles. [J Refract Surg. 2022;38(3):210-216.].
Collapse
|
12
|
Kling S. In-Vivo Measurement of Ocular Deformation in Response to Ambient Pressure Modulation. Front Bioeng Biotechnol 2021; 9:759588. [PMID: 34869269 PMCID: PMC8634479 DOI: 10.3389/fbioe.2021.759588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 10/26/2021] [Indexed: 11/20/2022] Open
Abstract
A novel approach is presented for the non-invasive quantification of axial displacement and strain in corneal and anterior crystalline lens tissue in response to a homogenous ambient pressure change. A spectral domain optical coherence tomography (OCT) system was combined with a custom-built set of swimming goggles and a pressure control unit to acquire repetitive cross-sectional scans of the anterior ocular segment before, during and after ambient pressure modulation. The potential of the technique is demonstrated in vivo in a healthy human subject. The quantification of the dynamic deformation response, consisting of axial displacement and strain, demonstrated an initial retraction of the eye globe (−0.43 to −1.22 nm) and a subsequent forward motion (1.99 nm) in response to the pressure change, which went along with a compressive strain induced in the anterior crystalline lens (−0.009) and a tensile strain induced in the cornea (0.014). These mechanical responses appear to be the result of a combination of whole eye motion and eye globe expansion. The latter simulates a close-to-physiologic variation of the intraocular pressure and makes the detected mechanical responses potentially relevant for clinical follow-up and pre-surgical screening. The presented measurements are a proof-of-concept that non-contact low-amplitude ambient pressure modulation induces tissue displacement and strain that is detectable in vivo with OCT. To take full advantage of the high spatial resolution this imaging technique could offer, further software and hardware optimization will be necessary to overcome the current limitation of involuntary eye motions.
Collapse
Affiliation(s)
- Sabine Kling
- OPTIC Team, Computer Vision Laboratory, ITET Department, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
13
|
Matveyev AL, Matveev LA, Moiseev AA, Sovetsky AA, Gelikonov GV, Zaitsev VY. Simulating scan formation in multimodal optical coherence tomography: angular-spectrum formulation based on ballistic scattering of arbitrary-form beams. BIOMEDICAL OPTICS EXPRESS 2021; 12:7599-7615. [PMID: 35003855 PMCID: PMC8713662 DOI: 10.1364/boe.440739] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 06/14/2023]
Abstract
We present a computationally highly efficient full-wave spectral model of OCT-scan formation with the following features: allowance of arbitrary phase-amplitude profile of illuminating beams; absence of paraxial approximation; utilization of broadly used approximation of ballistic scattering by discrete scatterers without limitations on their density/location and scattering strength. The model can easily incorporate the wave decay, dispersion, measurement noises with given signal-to-noise ratios and arbitrary inter-scan displacements of scatterers. We illustrate several of such abilities, including comparative simulations of OCT-scans for Bessel versus Gaussian beams, presence of arbitrary aberrations at the tissue boundary and various scatterer motions. The model flexibility and computational efficiency allow one to accurately study various properties of OCT-scans for developing new methods of their processing in various biomedical applications.
Collapse
Affiliation(s)
- Alexander L. Matveyev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Lev A. Matveev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Aleksandr A. Moiseev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Alexander A. Sovetsky
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Grigory V. Gelikonov
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| | - Vladimir Y. Zaitsev
- Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod, 603950, Russia
| |
Collapse
|
14
|
Real-Time Strain and Elasticity Imaging in Phase-Sensitive Optical Coherence Elastography Using a Computationally Efficient Realization of the Vector Method. PHOTONICS 2021. [DOI: 10.3390/photonics8120527] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
We present a real-time realization of OCT-based elastographic mapping local strains and distribution of the Young’s modulus in biological tissues, which is in high demand for biomedical usage. The described variant exploits the principle of Compression Optical Coherence Elastography (C-OCE) and uses processing of phase-sensitive OCT signals. The strain is estimated by finding local axial gradients of interframe phase variations. Instead of the popular least-squares method for finding these gradients, we use the vector approach, one of its advantages being increased computational efficiency. Here, we present a modified, especially fast variant of this approach. In contrast to conventional correlation-based methods and previously used phase-resolved methods, the described method does not use any search operations or local calculations over a sliding window. Rather, it obtains local strain maps (and then elasticity maps) using several transformations represented as matrix operations applied to entire complex-valued OCT scans. We first elucidate the difference of the proposed method from the previously used correlational and phase-resolved methods and then describe the proposed method realization in a medical OCT device, in which for real-time processing, a “typical” central processor (e.g., Intel Core i7-8850H) is sufficient. Representative examples of on-flight obtained elastographic images are given. These results open prospects for broad use of affordable OCT devices for high-resolution elastographic vitalization in numerous biomedical applications, including the use in clinic.
Collapse
|
15
|
García de Oteyza G, Álvarez de Toledo J, Barraquer RI, Kling S. Refractive changes of a new asymmetric intracorneal ring segment with variable thickness and base width: A 2D finite-element model. PLoS One 2021; 16:e0257222. [PMID: 34525102 PMCID: PMC8443075 DOI: 10.1371/journal.pone.0257222] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 08/25/2021] [Indexed: 12/02/2022] Open
Abstract
PURPOSE To evaluate the local geometric effects of a unilateral intrastromal ring segment with a combined variation of ring thickness and base width in a finite element simulation, and to compare it against the isolated effect of thickness or base width variation alone. METHODS A two-dimensional finite-element model of a transversely isotropic cornea was created assuming either axisymmetric stress or plane strain condition. The model geometry was composed of a three-layered corneal tissue (epithelium, anterior and posterior stroma) fixed at the limbus. The implantation of a triangular-shape asymmetric ring segment with varying ring thickness (150 to 300 μm) and base width (600 to 800 μm) was simulated. Also, changes induced by thickness or base width alone were studied and compared their combined effect in the asymmetric ring segment. Geometrical deformation of the simulated cornea and sagittal curvature were the main parameters of study. RESULTS Increasing ring thickness and base width along the arc of the asymmetric ring segment produced a more pronounced flattening in this part of the ring. The asymmetric design did find a good balance between maximizing corneal flattening at one end and minimizing it at the other end, compared to the isolated effect of ring thickness and width. Ring thickness was the most robust parameter in flattening both, the central and peripheral cornea. CONCLUSION The finite-element model permitted a theoretical study of corneal deformation undergoing implantation of realistic and hypothetical ring geometries. Intracorneal asymmetric ring segments with varying thickness and base width can be a good alternative in corneas with asymmetric keratoconus phenotypes.
Collapse
Affiliation(s)
- Gonzalo García de Oteyza
- Clínica Oftalmológica García de Oteyza, Barcelona, Spain
- Escuela de Doctorado, Universidad Autónoma de Barcelona (UAB), Barcelona, Spain
| | | | - Rafael I. Barraquer
- Centro de Oftalmología Barraquer, Barcelona, Spain
- Universitat Internacional de Catalunya (UIC), Barcelona, Spain
| | - Sabine Kling
- Department of Information Technology and Electrical Engineering, OPTIC Team, Computer-assisted Applications in Medicine Group, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
16
|
Kwok S, Hazen N, Clayson K, Pan X, Liu J. Regional variation of corneal stromal deformation measured by high-frequency ultrasound elastography. Exp Biol Med (Maywood) 2021; 246:2184-2191. [PMID: 34315279 DOI: 10.1177/15353702211029283] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The cornea's mechanical response to intraocular pressure elevations may alter in ectatic diseases such as keratoconus. Regional variations of mechanical deformation in normal and keratoconus eyes during intraocular pressure elevation have not been well-characterized. We applied a high-frequency ultrasound elastography technique to characterize the regional deformation of normal and keratoconus human corneas through the full thickness of corneal stroma. A cross-section centered at the corneal apex in 11 normal and 2 keratoconus human donor eyes was imaged with high-frequency ultrasound during whole globe inflation from 5 to 30 mmHg. An ultrasound speckle tracking algorithm was used to compute local tissue displacements. Radial, tangential, and shear strains were mapped across the imaged cross-section. Strains in the central (1 mm surrounding apex) and paracentral (1 to 4 mm from apex) regions were analyzed in both normal and keratoconus eyes. Additional regional analysis was performed in the eye with severe keratoconus presenting significant thinning and scarring. Our results showed that in normal corneas, the central region had significantly smaller tangential stretch than the paracentral region, and that within the central region, the magnitudes of radial and shear strains were significantly larger than that of tangential strain. The eye with mild keratoconus had similar shear strain but substantially larger radial strains than normal corneas, while the eye with severe keratoconus had similar overall strains as in normal eyes but marked regional heterogeneity and large strains in the cone region. These findings suggested regional variation of mechanical responses to intraocular pressure elevation in both normal and keratoconus corneas, and keratoconus appeared to be associated with mechanical weakening in the cone region, especially in resisting radial compression. Comprehensive characterization of radial, tangential, and shear strains through corneal stroma may provide new insights to understand the biomechanical alterations in keratoconus.
Collapse
Affiliation(s)
- Sunny Kwok
- Department of Biomedical Engineering, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA
| | - Nicholas Hazen
- Department of Biomedical Engineering, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA.,Biophysics Interdisciplinary Group, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA
| | - Keyton Clayson
- Department of Biomedical Engineering, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA.,Biophysics Interdisciplinary Group, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA
| | - Xueliang Pan
- Department of Biomedical Informatics, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA
| | - Jun Liu
- Department of Biomedical Engineering, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA.,Biophysics Interdisciplinary Group, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA.,Department of Ophthalmology and Visual Sciences, 2647The Ohio State University, The Ohio State University, Columbus, OH 43210-1110, USA
| |
Collapse
|
17
|
Wilson A, Marshall J. A review of corneal biomechanics: Mechanisms for measurement and the implications for refractive surgery. Indian J Ophthalmol 2021; 68:2679-2690. [PMID: 33229643 PMCID: PMC7856929 DOI: 10.4103/ijo.ijo_2146_20] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Detailed clinical assessment of corneal biomechanics has the potential to revolutionize the ophthalmic industry through enabling quicker and more proficient diagnosis of corneal disease, safer and more effective surgical treatments, and the provision of customized and optimized care. Despite these wide-ranging benefits, and an outstanding clinical need, the provision of technology capable of the assessment of corneal biomechanics in the clinic is still in its infancy. While laboratory-based technologies have progressed significantly over the past decade, there remain significant gaps in our knowledge regarding corneal biomechanics and how they relate to shape and function, and how they change in disease and after surgical intervention. Here, we discuss the importance, relevance, and challenges associated with the assessment of corneal biomechanics and review the techniques currently available and underdevelopment in both the laboratory and the clinic.
Collapse
Affiliation(s)
- Abby Wilson
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK
| | - John Marshall
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK
| |
Collapse
|
18
|
Nair A, Singh M, Aglyamov S, Larin KV. Heartbeat optical coherence elastography: corneal biomechanics in vivo. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200338LR. [PMID: 33624461 PMCID: PMC7901857 DOI: 10.1117/1.jbo.26.2.020502] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 01/19/2021] [Indexed: 05/02/2023]
Abstract
SIGNIFICANCE Mechanical assessment of the cornea can provide important structural and functional information regarding its health. Current clinically available tools are limited in their efficacy at measuring corneal mechanical properties. Elastography allows for the direct estimation of mechanical properties of tissues in vivo but is generally performed using external excitation force. AIM To show that heartbeat optical coherence elastography (Hb-OCE) can be used to assess the mechanical properties of the cornea in vivo. APPROACH Hb-OCE was utilized to detect Hb-induced deformations in the rabbit cornea in vivo without the need for external excitation. Furthermore, we demonstrate how this technique can distinguish corneal stiffness between untreated (UT) and crosslinked (CXL) tissue. RESULTS Our results demonstrate that stiffness changes in the cornea can be detected using only the Hb-induced deformations in the cornea. Additionally, we demonstrate a statistically significant difference in strain between the UT and CXL corneas. CONCLUSIONS Hb-OCE may be an effective tool for assessing the mechanical properties of the cornea in vivo without the need for external excitation. This tool may be effective for clinical assessment of corneal mechanical properties because it only requires optical coherence tomography imaging and data processing.
Collapse
Affiliation(s)
- Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Salavat Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Address all correspondence to Kirill V. Larin,
| |
Collapse
|
19
|
Zaitsev VY, Matveyev AL, Matveev LA, Sovetsky AA, Hepburn MS, Mowla A, Kennedy BF. Strain and elasticity imaging in compression optical coherence elastography: The two-decade perspective and recent advances. JOURNAL OF BIOPHOTONICS 2021; 14:e202000257. [PMID: 32749033 DOI: 10.1002/jbio.202000257] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/28/2020] [Accepted: 07/29/2020] [Indexed: 05/20/2023]
Abstract
Quantitative mapping of deformation and elasticity in optical coherence tomography has attracted much attention of researchers during the last two decades. However, despite intense effort it took ~15 years to demonstrate optical coherence elastography (OCE) as a practically useful technique. Similarly to medical ultrasound, where elastography was first realized using the quasi-static compression principle and later shear-wave-based systems were developed, in OCE these two approaches also developed in parallel. However, although the compression OCE (C-OCE) was proposed historically earlier in the seminal paper by J. Schmitt in 1998, breakthroughs in quantitative mapping of genuine local strains and the Young's modulus in C-OCE have been reported only recently and have not yet obtained sufficient attention in reviews. In this overview, we focus on underlying principles of C-OCE; discuss various practical challenges in its realization and present examples of biomedical applications of C-OCE. The figure demonstrates OCE-visualization of complex transient strains in a corneal sample heated by an infrared laser beam.
Collapse
Affiliation(s)
- Vladimir Y Zaitsev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander L Matveyev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Lev A Matveev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander A Sovetsky
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Matt S Hepburn
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| | - Alireza Mowla
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| | - Brendan F Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
20
|
Kling S, Torres-Netto EA, Spiru B, Sekundo W, Hafezi F. Quasi-Static Optical Coherence Elastography to Characterize Human Corneal Biomechanical Properties. Invest Ophthalmol Vis Sci 2021; 61:29. [PMID: 32539132 PMCID: PMC7415307 DOI: 10.1167/iovs.61.6.29] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Purpose Quasi-static optical coherence elastography (OCE) is an emerging technology to investigate corneal biomechanical behavior in situations similar to physiological stress conditions. Herein OCE was applied to evaluate previously inaccessible biomechanical characteristics of human corneal tissue and to study the role of Bowman's layer in corneal biomechanics. Methods Human corneal donor buttons (n = 23) were obtained and Descemet's membrane and endothelium were removed. In 11 corneas, Bowman's layer was ablated by a 20 µm stromal excimer laser ablation. Buttons were mounted on an artificial anterior chamber and subjected to a pressure modulation from 10 to 30 mm Hg, and back to 10 mm Hg, in steps of 1 mm Hg. At each step, a spectral-domain optical coherence tomography scan was obtained. Displacements were analyzed by optical flow tracking, and strain over the entire stromal depth was retrieved from the phase gradient of the complex interference signal. Results During pressure increase, corneal tissue moved upward (486–585 nm/mm Hg) but did not fully recover (Δ= 2.63 to 8.64 µm) after pressure decrease. Vertical corneal strain distribution was negative in the anterior and positive in the posterior cornea, indicating simultaneous corneal compression and expansion, respectively. Bowman's layer caused minor localized differences in corneal strain distribution. Conclusions Corneal strain distribution is more complex than previously assumed, with a fundamental difference in mechanical response between the anterior and posterior stroma. Clinically, OCE technology might be used to monitor the progression of corneal ectatic diseases and to determine the success of corneal cross-linking.
Collapse
|
21
|
Nair A, Singh M, Aglyamov SR, Larin KV. Heartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-9. [PMID: 32372574 PMCID: PMC7199791 DOI: 10.1117/1.jbo.25.5.055001] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Accepted: 04/24/2020] [Indexed: 05/04/2023]
Abstract
SIGNIFICANCE It is generally agreed that the corneal mechanical properties are strongly linked to many eye diseases and could be used to assess disease progression and response to therapies. Elastography is the most notable method of assessing corneal mechanical properties, but it generally requires some type of external excitation to induce a measurable displacement in the tissue. AIM We present Heartbeat Optical Coherence Elastography (Hb-OCE), a truly passive method that can measure the elasticity of the cornea based on intrinsic corneal displacements induced by the heartbeat. APPROACH Hb-OCE measurements were performed in untreated and UV-A/riboflavin cross-linked porcine corneas ex vivo, and a distinct difference in strain was detected. Furthermore, a partially cross-linked cornea was also assessed, and the treated and untreated areas were similarly distinguished. RESULTS Our results suggest that Hb-OCE can spatially map displacements in the cornea induced by small fluctuations in intraocular pressure, similar to what is induced by the heartbeat. CONCLUSIONS The described technique opens the possibility for completely passive and noncontact in vivo assessment of corneal stiffness.
Collapse
Affiliation(s)
- Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Address all correspondence to Kirill V. Larin, E-mail:
| |
Collapse
|