1
|
Marta A, Ferreira A, Couto I, Neves MM, Gomes M, Oliveira L, Azevedo Soares C, Menéres MJ, Lemos C, Melo Beirão J. Corneal Biomechanical Changes in Patients with Inherited Retinal Diseases. Clin Ophthalmol 2024; 18:2611-2618. [PMID: 39318485 PMCID: PMC11420929 DOI: 10.2147/opth.s478846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Accepted: 09/12/2024] [Indexed: 09/26/2024] Open
Abstract
Purpose Inherited retinal diseases (IRDs) are a group of degenerative disorders of the retina, that can be potentially associated with changes in the anterior segment, but their prevalence and impact are not known. Exploring these concomitant ophthalmologic changes with biomechanical assessment may help identify other non-retina causes of vision loss in these patients, such as corneal ectasia or susceptibility to glaucoma. This study aimed to measure and compare corneal biomechanics in patients with and without IRDs. Methods A total of 77 patients (154 eyes) with IRD were recruited as the study group. The control group consisted of 77 healthy adults (154 eyes) with matched age and sphere equivalents. All participants underwent a comprehensive assessment including corneal tomography (Pentacam®) and biomechanical assessment (Corvis ST®). A total of 4 second-generation biomechanical parameters and 3 indexes were collected: Ambrosio Relational Thickness (ARTh), Deflection Amplitude Ratio Max (DARM), Integrated Radius (IR) and Stiffness Parameter at Applanation (SP-A1), the final deviation value D of the Belin/Ambrosio Enhanced Ectasia Display (BAD-D), Corvis Biomechanical Index (CBI) and Tomographic Biomechanical Index (TBI). Results For IRD patients, there was a higher DARM (p < 0.001), lower ARTh (p < 0.001), higher CBI (p < 0.001), higher TBI (p<0.001), and higher BAD-D (p < 0.001) compared to the control group. Regarding discrimination of healthy subjects and IRD patients, ARTh was the most sensitive parameter. Conclusion The results showed that IRD patients tend to have softer corneal behaviour, compared to eyes without pathology, which may predispose patients to corneal ectasia or glaucoma development. ARTh could be used to screen IRD patients if a non-retina cause of vision loss is suspected.
Collapse
Affiliation(s)
- Ana Marta
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
- Instituto Ciências Biomédicas Abel Salazar (ICBAS), Porto, Portugal
| | - André Ferreira
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
- Department of Biomedicine - Unit of Anatomy, Faculty of Medicine of University of Porto, Porto, Portugal
- Centre for Health Technology and Services Research, Health Research Network (CINTESIS@RISE), Faculty of Medicine of the University of Porto, Porto, Portugal
| | - Inês Couto
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
| | - Miguel Mesquita Neves
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
| | - Miguel Gomes
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
| | - Luis Oliveira
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
| | - Celia Azevedo Soares
- Medical Genetics Department, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
- Unit for Multidisciplinary Research in Biomedicine, Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal
- Medical Science Department, Universidade de Aveiro, Aveiro, Portugal
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, Portugal
| | - Maria João Menéres
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
- Instituto Ciências Biomédicas Abel Salazar (ICBAS), Porto, Portugal
| | - Carolina Lemos
- Instituto Ciências Biomédicas Abel Salazar (ICBAS), Porto, Portugal
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, Portugal
| | - João Melo Beirão
- Department of Ophthalmology, Centro Hospitalar Universitário de Santo António, Unidade Local de Saúde de Santo António, Porto, Portugal
- Instituto Ciências Biomédicas Abel Salazar (ICBAS), Porto, Portugal
| |
Collapse
|
2
|
Yang Y, Chu Z, Cheng L, Cheng H, Ren Q. Potential dynamic corneal response parameters for myopia: relationships between axial length with whole eye movement at the first and second applanations and the highest concavity. BMC Ophthalmol 2024; 24:382. [PMID: 39198780 PMCID: PMC11351076 DOI: 10.1186/s12886-024-03635-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 08/13/2024] [Indexed: 09/01/2024] Open
Abstract
PURPOSE To investigate the correlation between whole eye movement (WEM) parameters measured using Corvis ST and axial length (AL) to explore whether AL affects WEMs. METHODS This single-center, cross-sectional study included data from healthy subjects and patients preparing for refractive surgery at the Qingdao Eye Hospital of Shandong First Medical University. Data were collected from July 2021 to April 2022. We first determined the correlations of WEMs at the time of corneal first applanation (A1_WEM), highest concavity (HC_WEM), and second applanation (A2_WEM), as well as the maximum value of WEM (WEM_Max) with AL. Subsequently, we established a series of regression models to analyze the relationships between different WEM values and AL. RESULTS AL was negatively correlated with HC_WEM, A2_WEM, and WEM_Max (r = - 0.28, - 0.23, and - 0.22, respectively; P < 0.001). The correlation between AL and A1_WEM was not significant (P = 0.77). According to the adjusted regression models, AL was negatively associated with HC_WEM (Model 2: β = -7.39, P < 0.001) and WEM_Max (Model 4: β = -3.52, P = 0.02), while the associations of AL with A1_WEM (Model 1: P = 0.61) and A2_WEM (Model 3: P = 0.23) were not significant. CONCLUSIONS AL is an independent negative influencing factor for HC_WEM. WEM is a potentially useful parameter that reflects the biomechanical properties of the eye behind the cornea in myopia.
Collapse
Affiliation(s)
- Ye Yang
- Department of Ophthalmology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Zhe Chu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Lu Cheng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University Guangzhou, Guangzhou, China
| | - Hao Cheng
- Department of Ophthalmology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
| | - Qi Ren
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China.
- School of Ophthalmology, Shandong First Medical University, Qingdao, China.
| |
Collapse
|
3
|
Liu MX, Li DL, Yin ZJ, Li YZ, Zheng YJ, Qin Y, Ma R, Liang G, Pan CW. Corneal stress‒strain index in relation to retinal nerve fibre layer thickness among healthy young adults. Eye (Lond) 2024; 38:1654-1659. [PMID: 38402288 PMCID: PMC11156841 DOI: 10.1038/s41433-024-02985-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 01/19/2024] [Accepted: 02/05/2024] [Indexed: 02/26/2024] Open
Abstract
BACKGROUND/OBJECTIVES To determine the relationship between corneal stress-strain index (SSI) and retinal nerve fibre layer (RNFL) thickness. SUBJECTS/METHODS 1645 healthy university students from a university-based study contributed to the analysis. The RNFL thickness was measured by high-definition optical coherence tomography (HD-OCT), axial length (AL) was measured by IOL Master, and corneal biomechanics including SSI, biomechanical corrected intraocular pressure (bIOP), and central corneal thickness (CCT) were measured by Corvis ST. Multivariate linear regression was performed to evaluate the relationship between the SSI and RNFL thickness after adjusting for potential covariates. RESULTS The mean age of the participants was 19.0 ± 0.9 years, and 1132 (68.8%) were women. Lower SSI was significantly associated with thinner RNFL thickness ( β =8.601, 95% confidence interval [CI] 2.999-14.203, P = 0.003) after adjusting for age, CCT, bIOP, and AL. No significant association between SSI and RNFL was found in men, while the association was significant in women in the fully adjusted model. The association was significant in the nonhigh myopic group ( P for trend = 0.021) but not in the highly myopic group. Eyes with greater bIOP and lower SSI had significantly thinner RNFL thickness. CONCLUSIONS Eyes with lower SSI had thinner RNFL thickness after adjusting for potential covariates, especially those with higher bIOP. Our findings add novel evidence of the relationship between corneal biomechanics and retinal ganglion cell damage.
Collapse
Affiliation(s)
- Min-Xin Liu
- School of Public Health, Suzhou Medical College of Soochow University, Suzhou, China
| | - Dan-Lin Li
- School of Public Health, Suzhou Medical College of Soochow University, Suzhou, China
| | - Zhi-Jian Yin
- Department of Ophthalmology, the First Affiliated Hospital of Dali University, Dali, China
| | - Yue-Zu Li
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Ya-Jie Zheng
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Yu Qin
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Rong Ma
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, Kunming, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Gang Liang
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, Kunming, China.
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China.
| | - Chen-Wei Pan
- School of Public Health, Suzhou Medical College of Soochow University, Suzhou, China.
| |
Collapse
|
4
|
Wang D, Chang Y, Nan W, Zhang Y. Comparative analysis of corneal parameters in simple myopic anisometropia using Scheimpflug technology. Front Bioeng Biotechnol 2024; 12:1366408. [PMID: 38840667 PMCID: PMC11150699 DOI: 10.3389/fbioe.2024.1366408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/06/2024] [Indexed: 06/07/2024] Open
Abstract
Purpose This study aims to investigate the differences in binocular corneal parameters and their interrelation with binocular biometric parameters asymmetry in patients with simple myopic anisometropia, thereby elucidating the influence of myopia process on various corneal parameters. Methods In this cross-sectional study, 65 patients with anisometropia in monocular myopia were included. They were divided into low anisometropia group: 3.00D<Δ spherical equivalent (SE)≤-1.00D (Δ represents the difference between the two eyes, i.e., myopic data minus emmetropic data) and high anisometropia group: ΔSE ≤ -3.00D. Corneal and ocular biometric parameters were measured using Pentacam, Corvis ST, and IOL Master 700. Statistical analyses focused on the binocular corneal parameters asymmetry, using the contralateral emmetropia as a control. Results The mean age of participants was 18.5 ± 1.3 years, with the average SE for myopia and emmetropia being -2.93 ± 1.09D and -0.16 ± 0.41D, respectively. The central corneal thickness (CCT), flat keratometry (Kf), keratometry astigmatism (Ka), total corneal aberration (6 mm) (TOA), surface variance index (ISV), vertical asymmetry index (IVA), stress-strain index (SSI), and first applanation stiffness parameter (SPA1) and ambrosia relational thickness-horizontal (ARTh) showed significant differences between anisometropic fellow eyes (p < 0.05). There were significant differences in ΔIVA, Δ the difference between the mean refractive power of the inferior and superior corneas (I-S), Δ deviation value of Belin/Ambrósio enhanced ectasia display (BAD-D), Δ deformation amplitude ratio max (2 mm) (DAR)and Δ tomographic biomechanical index (TBI) (p < 0.05) in two groups. Asymmetry of corneal parameters was correlated with asymmetry of ocular biometric parameters. Anisometropia (ΔSE) was positively correlated with ΔIVA (r = 0.255, p = 0.040), ΔBAD-D (r = 0.360, p = 0.006), and ΔSSI (r = 0.276, p = 0.039) and negatively correlated with ΔDAR (r = -0.329, p = 0.013) in multiple regression analysis. Δ mean keratometry (Km), Δ anterior chamber depth (ACD), and Δ biomechanically corrected intraocular pressure (bIOP) were also associated with binocular corneal differences. Conclusion Compared to contralateral emmetropia, myopic eyes have thinner corneas and smaller corneal astigmatism. Myopic corneas exhibit relatively more regular surface morphology but are more susceptible to deformation and possess marginally inferior biomechanical properties. In addition, there is a certain correlation between anisometropia and corneal parameter asymmetry, which would be instrumental in predicting the development of myopia.
Collapse
Affiliation(s)
- Di Wang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Yue Chang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Weijin Nan
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yan Zhang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
5
|
Marques JH, Baptista PM, Ribeiro B, Menéres P, Beirão JM. Intraocular lens power calculation: angle κ and ocular biomechanics. J Cataract Refract Surg 2024; 50:345-351. [PMID: 37962186 DOI: 10.1097/j.jcrs.0000000000001362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 11/02/2023] [Indexed: 11/15/2023]
Abstract
PURPOSE To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation. SETTING Centro Hospitalar Universitário do Porto, Porto, Portugal. DESIGN Prospective longitudinal study. METHODS This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis. RESULTS Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle κ, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth ( B = -0.279, P = .021) and CBI ( B = -0.520, P = .013) and AE was associated with angle κ ( B = -0.370, P = .007). CONCLUSIONS A large angle κ may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.
Collapse
Affiliation(s)
- João Heitor Marques
- From the Serviço de Oftalmologia, Centro Hospitalar Universitário do Porto, Porto, Portugal (Marques, Baptista, Ribeiro, Menéres, Beirão); Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal (Baptista, Menéres, Beirão)
| | | | | | | | | |
Collapse
|
6
|
El-Mayah E, Albalkini AS, Barrada OA. Characterization of Corneal Biomechanics Using CORVIS ST Device in Different Grades of Myopia in a Sample of Middle Eastern Ethnicity. Clin Ophthalmol 2024; 18:901-912. [PMID: 38529005 PMCID: PMC10962271 DOI: 10.2147/opth.s451328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/22/2024] [Indexed: 03/27/2024] Open
Abstract
Purpose To characterize corneal biomechanical properties using the CORVIS-ST device in myopic individuals. Methods This prospective cross-sectional study included patients with myopia. Our study included 154 eyes of 154 myopic patients aged between 18 and 40 years, with stable refraction for at least 2 years. A full ophthalmological examination and corneal tomography were performed using a Pentacam HR device. Corneal biomechanical parameters were assessed using the CORVIS-ST device in mild, moderate, severe, and extreme myopia groups. Results Statistically significant differences were observed in the DA ratio (p = 0.033), SP-A (p=0.009), CBI (p=0.041), SSI (p=0.000), and Peak distance (p = 0.032). In correlation with different Corvis ST biomechanical variables, SE was found to be correlated with DA ratio(r=-0.191, p=0.018), SP-A(r=0.199, p=0.013) and SSI(r=-0.336, p=0.000), while in multiple regression analysis, SE was found to be independently correlated with SSI and peak distance(p=0.036,0.038 respectively) while the grade of myopia was found to be independently correlated with SP-A(p=0.034). Conclusion SSI, Peak distance, and SP-A were independently related to SE and myopia grade, confirming the hypothesis that eyes with higher myopia are more deformable and less stress resistant.
Collapse
Affiliation(s)
- Esraa El-Mayah
- Ophthalmology Department, Kasr Alainy School of Medicine, Cairo University, Cairo, Egypt
| | - Ahmed Saad Albalkini
- Ophthalmology Department, Kasr Alainy School of Medicine, Cairo University, Cairo, Egypt
| | - Omar A Barrada
- Ophthalmology Department, Kasr Alainy School of Medicine, Cairo University, Cairo, Egypt
| |
Collapse
|
7
|
Li DL, Liu MX, Yin ZJ, Li YZ, Ma R, Zheng YJ, Qin Y, Liang G, Pan CW. Refractive associations with corneal biomechanical properties among young adults: a population-based Corvis ST study. Graefes Arch Clin Exp Ophthalmol 2024; 262:121-132. [PMID: 37401934 DOI: 10.1007/s00417-023-06164-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 06/11/2023] [Accepted: 06/28/2023] [Indexed: 07/05/2023] Open
Abstract
PURPOSE To assess the associations of corneal biomechanical properties as measured by the Corvis ST with refractive errors and ocular biometry in an unselected sample of young adults. METHODS A total of 1645 healthy university students underwent corneal biomechanical parameters measurement by the Corvis ST. The refractive status of the participants was measured using an autorefractor without cycloplegia. Ocular biometric parameters were measured using the IOL Master. RESULTS After adjusting for the effect of age, sex, biomechanical-corrected intraocular pressure and central corneal thickness, axial length was significantly associated with A1 velocity (A1v, β = -10.47), A2 velocity (A2v, β = 4.66), A2 deflection amplitude (A2DeflA, β = -6.02), HC deflection amplitude (HC-DeflA, β = 5.95), HC peak distance (HC-PD, β = 2.57), deformation amplitude ratio max (DA Rmax, β = -0.36), Ambrósio's relational thickness to the horizontal profile (ARTh, β = 0.002). For axial length / corneal radius ratio, only A1v (β = -2.01), A1 deflection amplitude (A1DeflA, β = 2.30), HC-DeflA (β = 1.49), HC-PD (β = -0.21), DA Rmax (β = 0.07), stress-strain index (SSI, β = -0.29), ARTh (β < 0.001) were significant associates. A1v (β = 23.18), HC-DeflA (β = -15.36), HC-PD (β = 1.27), DA Rmax (β = -0.66), SSI (β = 3.53), ARTh (β = -0.02) were significantly associated with spherical equivalent. CONCLUSION Myopic eyes were more likely to have more deformable corneas and corneas in high myopia were easier to deform and were even softer compared with those in the mild/moderate myopia.
Collapse
Affiliation(s)
- Dan-Lin Li
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China
| | - Min-Xin Liu
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China
| | - Zhi-Jian Yin
- Department of Ophthalmology, the First Affiliated Hospital of Dali University, Dali, China
| | - Yue-Zu Li
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Rong Ma
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Ya-Jie Zheng
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Yu Qin
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China
| | - Gang Liang
- Department of Ophthalmology, the Affiliated Hospital of Yunnan University, 176 Qing Nian Road, Kunming, 650021, China.
- Department of Ophthalmology, the Second People's Hospital of Yunnan Province, Kunming, China.
| | - Chen-Wei Pan
- School of Public Health, Medical College of Soochow University, 199 Ren Ai Road, Suzhou, 215123, China.
| |
Collapse
|
8
|
Kenia VP, Kenia RV, Bendre P, Pirdankar OH. Corneal stress-strain index in myopic Indian population. Oman J Ophthalmol 2024; 17:47-52. [PMID: 38524314 PMCID: PMC10957058 DOI: 10.4103/ojo.ojo_122_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 11/18/2023] [Indexed: 03/26/2024] Open
Abstract
AIM The purpose is to study the corneal stress-strain index (SSI) in myopic refractive error among Indian subjects. METHODS A retrospective study where young myopic subjects aged between 11 and 35 years who had undergone corneal biomechanics assessment using Corvis ST between January 2017 and December 2021 were enrolled. Subjects with central corneal thickness (CCT) <500 μ, intraocular pressure (IOP) >21 mmHg, history of any systemic and ocular disease or any previous ocular surgery, high astigmatism, corneal disease such as keratoconus were excluded. Subjects with missing data or having poor quality scan were excluded. Corneal biomechanical properties and corneal SSI were assessed using Corvis ST. For statistical purposes, eyes were divided into four different groups and were analyzed using one-way ANOVA. RESULTS Nine hundred and sixty-six myopic eyes with mean ± standard deviation age, IOP, and CCT of 26.89 ± 4.92 years, 16.94 ± 2.00 mmHg, and 540.18 ± 25.23 microns, respectively, were included. There were 311, 388, 172, and 95 eyes that were low, moderate, severe, and extreme myopic. Deformation amplitude ratio at 1 mm and 2 mm were similar across different myopic groups. A significant increase in max inverse radius, ambrosia relational thickness, biomechanically corrected IOP, integrated radius was noted with an increase in myopic refractive error. Corvis biomechanical index, corneal SSI was found to be decreased significantly with an increase in myopic refractive error. We noted a significant positive association between myopic refractive error and SSI (P < 0.001). CONCLUSION Corneal SSI was found to be reduced in extreme myopic eyes.
Collapse
Affiliation(s)
- Vaishal P. Kenia
- Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India
| | - Raj V. Kenia
- Department of Ophthalmology, Kenia Foundation, Mumbai, Maharashtra, India
| | - Pradnya Bendre
- Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India
| | | |
Collapse
|
9
|
Chu Z, Ren Q, Su W, Cui W, Wu J. Effect of central corneal curvature on corneal material stiffness parameter acquired by dynamic corneal responses. Front Bioeng Biotechnol 2023; 11:1237834. [PMID: 37920247 PMCID: PMC10619688 DOI: 10.3389/fbioe.2023.1237834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 10/09/2023] [Indexed: 11/04/2023] Open
Abstract
The stress-strain index (SSI) is a measure of corneal material stiffness, which is obtained using the Corvis ST algorithm based on dynamic corneal response parameters. The reduced SSI corresponds to the longer axial length (AL). In a previous study, we found SSI increases as the corneal curvature flattens, whereas a flatter corneal curvature indicates a longer AL (emmetropia or myopia). Therefore, in this cross-sectional study, we aimed to address these contradictory findings. First, we characterized the features of SSI, curvature radius of the anterior corneal surface (CR), and AL and analyzed their correlation with advanced myopia. Next, we compared the relationship between AL and SSI after adjusting for the effect of CR. We found a significant positive correlation between SSI and CR, which contradicts the developmental law of axial myopia. Furthermore, after accounting for the effect of CR, we observed a stronger correlation between SSI and AL than that in the unadjusted model. In conclusion, CR is an independent influencing factor for SSI in addition to AL, which masked the decrease in SSI caused by prolonged AL in axial myopia.
Collapse
Affiliation(s)
- Zhe Chu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Qi Ren
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Wenjie Su
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Wei Cui
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Jie Wu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| |
Collapse
|
10
|
Yang Z, Wu B, Li Z, Yu M, Jiang J, Chen S, Xu S, Zeng J, Wang M, Yang X. Changes in Stress-Strain Index in School-Aged Children: A 3-Year Longitudinal Study. J Ophthalmol 2023; 2023:6680748. [PMID: 37868693 PMCID: PMC10590269 DOI: 10.1155/2023/6680748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 09/22/2023] [Accepted: 09/23/2023] [Indexed: 10/24/2023] Open
Abstract
Purpose To determine three-year change of the corneal biomechanical parameter stress-strain index (SSI) in schoolchildren aged 7- 9 years and their correlation with refractive error and axial length (AL). Methods This is a prospective cohort study. Data of the AL, refractive error, and corneal biomechanical parameter SSI were collected at baseline and a 3-year follow-up for 217 schoolchildren. SSI, AL, and refractive error were measured via corneal visualization Scheimpflug technology (Corvis ST), IOLMaster biometry, and cycloplegic refraction. Three years of changes in SSI and its association with refractive error and AL were analyzed. Participants were divided into persistent nonmyopia (PNM), newly developed myopia (NDM), and persistent myopia (PM). The three-year difference in SSI among the three groups was analyzed. Results After three years of follow-up, the corneal biomechanical parameter SSI decreased in all participants (P < 0.01). There was a negative correlation between the change in SSI and the change in AL (r = -0.205, P=0.002) and a positive correlation between the change in refractive error (r = 0.183, P=0.007). After three years of follow-up, there was a decrease in the SSI for the NDM, PM, and PNM participants, with a median change of -0.05 for PNM and -0.13 and -0.09 for the NDM and PM, respectively. There was a significant decrease in corneal biomechanical properties for NDM patients compared with PNM patients (P < 0.01). Conclusion In 7- to 9-year-old schoolchildren, SSI decreased after three years of the longitudinal study, and the change in SSI was correlated with the change in AL and refractive error. There was a rapid decrease in corneal biomechanical properties among newly developed myopic patients.
Collapse
Affiliation(s)
- Zhengfei Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Bo Wu
- South China Hospital, Shenzhen University, Shenzhen, China
| | - Zhouyue Li
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Mengting Yu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Jinyun Jiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Shuyuan Chen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Shengsong Xu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Junwen Zeng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Mengyi Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Xiao Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
11
|
Chen L, Huang Y, Zhang X, Shi Y, Gao Z, Sun B, Shen Y, Sun L, Cao Y, Zhang Q, Guo J, Li F, Chen W, Li X, Zhou X. Corneal Biomechanical Properties Demonstrate Anisotropy and Correlate With Axial Length in Myopic Eyes. Invest Ophthalmol Vis Sci 2023; 64:27. [PMID: 37477932 PMCID: PMC10365135 DOI: 10.1167/iovs.64.10.27] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 06/12/2023] [Indexed: 07/22/2023] Open
Abstract
Purpose The purpose of this study was to investigate the ex vivo and in vivo biomechanical characteristic of cornea in myopic eyes. Methods Fifty-one corneal stromal lenticules were obtained from myopic eyes during the SMILE procedure and were tested by a biaxial tensile system within 24 hours postoperatively. The material properties of the lenticules were described using stress-strain curves and were compared among axial length (AL) <26 mm and AL ≥ 26 mm group. Pre-operative stress-strain index (SSI) parameters were used to evaluate the biomechanical properties of the cornea in vivo. Results Compared with AL < 26 mm, the tangent modulus significantly decreased in horizontal and vertical directions when AL ≥ 26 mm (P < 0.05); SSI also significantly decreased when AL ≥ 26 mm (P < 0.05). Anisotropic parameter is positively correlated with AL (r = 0.307, P < 0.05). Compared with AL < 26 mm, anisotropic parameter significantly increased when AL ≥ 26 mm (P < 0.05). SSI was negatively correlated with AL (r = -0.380, P < 0.05) in the AL < 26 mm group but not in the AL ≥ 26 mm group (P > 0.05). Compared with 26 mm ≤ AL < 27 mm group, the tangent modulus significantly decreased in the horizontal direction (P < 0.05) but not in the vertical direction when 27 mm ≤ AL < 28 mm (P > 0.05). Conclusions The biomechanical properties of cornea decreased with the increase of AL. Tangent modulus significantly decreased in the horizontal direction compared with vertical direction. AL should be taken into account during calculation of corneal biomechanical parameters in order to improve validity.
Collapse
Affiliation(s)
- Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Yangyi Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yike Shi
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Zhipeng Gao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Bingqing Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Ling Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yifan Cao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Qianqian Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- School of Automation and Software Engineering, Shanxi University, Taiyuan, Shanxi, China
| | - Jiqiang Guo
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
| | - Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan, China
- Institute of Applied Mechanics, Taiyuan University of Technology, Taiyuan, China
| | - Weiyi Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xiaona Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| |
Collapse
|
12
|
Kaur K, Gurnani B. Commentary: A novel way to assess corneal biomechanics in human eyes - The corneal stress-strain index. Indian J Ophthalmol 2023; 71:2427-2428. [PMID: 37322653 PMCID: PMC10417971 DOI: 10.4103/ijo.ijo_300_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023] Open
Affiliation(s)
- Kirandeep Kaur
- Cataract Pediatric Ophthalmology and Strabismus, Shri Sadguru Seva Sangh Trust, Chitrakoot, Madhya Pradesh, India
| | - Bharat Gurnani
- Cataract, Cornea, External Diseases, Trauma, Ocular Surface and Refractive Services, Sadguru Netra Chikitsalaya, Shri Sadguru Seva Sangh Trust, Chitrakoot, Madhya Pradesh, India
| |
Collapse
|
13
|
Wei Y, Cai Y, Bao C, Zhu Y, Pan Y. The role of corneal biomechanics in visual field progression of primary open-angle glaucoma with ocular normotension or hypertension: a prospective longitude study. Front Bioeng Biotechnol 2023; 11:1174419. [PMID: 37234476 PMCID: PMC10206210 DOI: 10.3389/fbioe.2023.1174419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Accepted: 04/20/2023] [Indexed: 05/28/2023] Open
Abstract
Introduction: To analyze effects of dynamic corneal response parameters (DCRs) on visual field (VF) progression in normal-tension glaucoma (NTG) and hypertension glaucoma (HTG). Methods: This was a prospective cohort study. This study included 57 subjects with NTG and 54 with HTG, followed up for 4 years. The subjects were divided into progressive and nonprogressive groups according to VF progression. DCRs were evaluated by corneal visualization Scheimpflug technology. General linear models (GLMs) were used to compare DCRs between two groups, adjusting for age, axial length (AL), mean deviation (MD), etc. VF progression risk factors were evaluated by logistic regression and receiver operating characteristic (ROC) curves. Results: For NTG, first applanation deflection area (A1Area) was increased in progressive group and constituted an independent risk factor for VF progression. ROC curve of A1Area combined with other relevant factors (age, AL, MD, etc.) for NTG progression had an area under curve (AUC) of 0.813, similar to the ROC curve with A1area alone (AUC = 0.751, p = 0.232). ROC curve with MD had an AUC of 0.638, lower than A1Area-combined ROC curve (p = 0.036). There was no significant difference in DCRs between the two groups in HTG. Conclusion: Corneas in progressive NTG group were more deformable than nonprogressive group. A1Area may be an independent risk factor for NTG progression. It suggested that the eyes with more deformable corneas may also be less tolerant to pressure and accelerate VF progression. VF progression in HTG group was not related to DCRs. Its specific mechanism needs further studies.
Collapse
Affiliation(s)
| | - Yu Cai
- *Correspondence: Yu Cai, ; Yingzi Pan,
| | | | | | | |
Collapse
|
14
|
Du Y, Zhang Y, Zhang Y, Li T, Wang J, Du Z. Analysis of potential impact factors of corneal biomechanics in myopia. BMC Ophthalmol 2023; 23:143. [PMID: 37024820 PMCID: PMC10077661 DOI: 10.1186/s12886-023-02891-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 03/31/2023] [Indexed: 04/08/2023] Open
Abstract
PURPOSE To investigate potential impact factors associated with corneal biomechanical properties in Chinese myopia and further to investigate quantifying corneal biomechanics in clinical work. METHODS Three hundred fifty-five eyes from 181 healthy myopic subjects with a mean age of 25.1 ± 9.4 were recruited in this study. Each patient carried out a comprehensive ophthalmic examination, including corneal hysteresis(CH), corneal resistance factor(CRF), central corneal thickness(CCT), axial length(AL), intraocular pressure(IOP), spherical equivalence(SE) and corneal curvature (K). CH and CRF were measured with the ocular response analyzer(ORA). To analyze the corneal biomechanical characteristics of myopia patients and their association with other parameters. RESULT The multiple linear regression analysis showed that CH was positively associated with CCT, and corneal curvature (all with P < 0.05) and negatively associated with SE and AL)(all with P < 0.05); CRF was positively correlated with CCT, corneal curvature and IOP(all with P < 0.05), but negatively correlated with SE and AL(all with P < 0.05). The CH and CRF values in children group were both higher than adults group (≥ 18 years old) (P < 0.05), but it attributed to that the CCT of children was thicker than adults. Excluding factor of CCT, there was no significant difference in CH and CRF between children group and adult group. Excluding factor of CCT, there was no significant difference in CH and CRF among different stage of age (age 18-48). CONCLUSION The CCT played the most important role of affecting the CH and CRF. The SE, corneal curvature, AL and IOP had a certain influence on corneal biomechanics. Whether the CH and CRF values of individual patient are normal in clinical work, it should refer to the CH and CRF values corresponding CCT sectional range and SE.
Collapse
Affiliation(s)
- Yangrui Du
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China
- Medal Eye Institute, Chongqing, China
| | - Yuqing Zhang
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China
| | - Yu Zhang
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China
- Medal Eye Institute, Chongqing, China
| | - Tao Li
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China
| | - Jie Wang
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China
| | - Zhiyu Du
- Department of Ophthalmology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, People's Republic of China.
| |
Collapse
|
15
|
Lin W, Li N, Lu K, Li Z, Zhuo X, Wei R. The relationship between baseline axial length and axial elongation in myopic children undergoing orthokeratology. Ophthalmic Physiol Opt 2023; 43:122-131. [PMID: 36377631 PMCID: PMC10100030 DOI: 10.1111/opo.13070] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/07/2022] [Accepted: 10/18/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To investigate the correlation between the baseline axial length (AL) and axial elongation in myopes undergoing orthokeratology (ortho-k). METHODS This was a retrospective study. During the 1-year follow-up, 1176 children (aged 8-14 years) were included and divided into an ortho-k group (n = 588) and a single-vision spectacle group (n = 588). The ortho-k group participants (8-11 years of age) who completed the 3-year follow-up (n = 150) were further divided into three subgroups stratified by their baseline AL: subgroup 1 (AL < 24.5 mm), subgroup 2 (24.5 ≤ AL < 26 mm) and subgroup 3 (AL ≥ 26 mm). AL was measured at baseline and during the annual visit. RESULTS The ortho-k group exhibited slower 1-year axial elongation (39% reduction) than the spectacle group. The 1-year axial elongation was negatively correlated with initial age in both groups. A negative association between 1-year axial elongation and baseline AL was observed in the ortho-k group but not in the spectacle group. However, this relationship only existed in ortho-k participants 8-11 years of age. For the younger ortho-k participants who completed the 3-year follow-up, the annual axial elongation was significantly higher in subgroup 1 for the first and second years but not in the third year compared with subgroups 2 and 3. CONCLUSION Axial elongation was negatively correlated with baseline AL in the ortho-k group. Children aged 8-11 years with longer baseline AL (≥24.5 mm) demonstrated slower annual axial elongation during the first 2 years of ortho-k treatment, which may provide insight into establishing individual guidelines for controlling myopia using ortho-k in children with different baseline characteristics.
Collapse
Affiliation(s)
- Weiping Lin
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Na Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Kunpeng Lu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Zhaochun Li
- Euclid China (Euclid Trading (Shanghai) Ltd.), Shanghai, China
| | - Xiaohua Zhuo
- Euclid China (Euclid Trading (Shanghai) Ltd.), Shanghai, China
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| |
Collapse
|
16
|
Ren Q, Chu Z, Cui W, Cheng L, Su W, Cheng H, Wu J. Effect of corneal stiffness decrease on axial length elongation in myopia determined based on a mathematical estimation model. Front Bioeng Biotechnol 2023; 11:1145032. [PMID: 37101753 PMCID: PMC10123270 DOI: 10.3389/fbioe.2023.1145032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Accepted: 03/31/2023] [Indexed: 04/28/2023] Open
Abstract
Purpose: To investigate the relationship between the corneal material stiffness parameter stress-strain index (SSI) and axial length (AL) elongation with varying severities of myopia, based on a mathematical estimation model. Methods: This single-center, cross-sectional study included data from healthy subjects and patients preparing for refractive surgery in the Qingdao Eye Hospital of Shandong First Medical University. Data were collected from July 2021 to April 2022. First, we performed and tested an estimated AL model ( A L M o r g a n ) based on the mathematical equation proposed by Morgan. Second, we proposed an axial increment model ( Δ A L ) corresponding to spherical equivalent error (SER) based on A L e m m e t r o p i a ( A L M o r g a n at SER = 0) and subject's real AL. Finally, we evaluated the variations of Δ A L with SSI changes based on the mathematical estimation model. Results: We found that AL was closely associated with A L M o r g a n (r = 0.91, t = 33.8, p < 0.001) with good consistency and SER was negatively associated with Δ A L (r = -0.89, t = -30.7, p < 0.001). The association of SSI with AL, A L e m m e t r o p i a , and Δ A L can be summarized using the following equations: A L = 27.7 - 2.04 × S S I , A L e m m e t r o p i a = 23.2 + 0.561 × S S I , and Δ A L = 4.52 - 2.6 × S S I . In adjusted models, SSI was negatively associated with AL (Model 1: β = -2.01, p < 0.001) and Δ A L (Model 3: β = -2.49, p < 0.001) but positively associated with A L e m m e t r o p i a (Model 2: β = 0.48, p < 0.05). In addition, SSI was negatively associated with Δ A L among subjects with AL ≥ 26 mm (β = -1.36, p = 0.02). Conclusion: AL increased with decreasing SSI in myopia.
Collapse
Affiliation(s)
- Qi Ren
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Zhe Chu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Wei Cui
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Lu Cheng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Wenjie Su
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Hao Cheng
- Department of Ophthalmology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Jie Wu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- School of Ophthalmology, Shandong First Medical University, Qingdao, China
- *Correspondence: Jie Wu,
| |
Collapse
|
17
|
Liu Y, Pang C, Ming S, Fan Q. Effect of myopia and astigmatism deepening on the corneal biomechanical parameter stress-strain index in individuals of Chinese ethnicity. Front Bioeng Biotechnol 2022; 10:1018653. [PMID: 36420440 PMCID: PMC9676639 DOI: 10.3389/fbioe.2022.1018653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 10/10/2022] [Indexed: 11/09/2022] Open
Abstract
Purpose: To investigate the differences in corneal biomechanical parameter stress–strain index (SSI) among different degrees of myopic eyes in Chinese individuals and to analyze the relevant factors of the SSI. Methods: This study analyzed the right eyes of 240 participants (240 eyes) aged 18–34 years. The participants were divided into low-, moderate-, high-, and ultra-high myopia groups according to their spherical equivalent (SE), with 60 eyes included in each group. Spherical, cylinder, and SE were measured via automatically integrated optometry. Intraocular pressure (IOP) was measured using a non-contact tonometer. AL was measured using an IOLMaster device. Corneal curvature and central corneal thickness (CCT) were measured using a Pentacam. SSI and biomechanical corrected IOP (bIOP) were measured via corneal visualization Scheimpflug technology (Corvis ST). The statistical analyses included one-sample Kolmogorov–Smirnov tests and normal distribution histogram methods, Levene variance homogeneity tests, Pearson’s correlation analyses, multiple linear stepwise regression analyses, one-way ANOVA, and LSD t-tests. Results: The mean (±SD) age of the 240 participants was (24.97 ± 4.16) years. The SSI was positively correlated with spherical, cylinder, SE, CCT, IOP, and bIOP and negatively correlated with K1 and AL (r = 0.475, 0.371, 0.497, 0.169, 0.291, 0.144, −0.154, and −0.464, respectively; all p < 0.05), but were not correlated with age, K2, or Km (all p > 0.05). Multiple linear regression analysis performed with SSI as the dependent variable, and spherical, cylinder, K1, CCT, and IOP as independent variables produced the following regression equation: SSI = 0.989 + 0.017 spherical + 0.042 cylinder +0.018 IOP (R2 = 0.402, F = 31.518, p < 0.001). The SSI values in the low-, moderate-, high-, and ultra-high myopia groups were 0.945 ± 0.135, 0.940 ± 0.128, 0.874 ± 0.110, and 0.771 ± 0.104, respectively. The values decreased sequentially, and the differences between pairs were statistically significant (all p < 0.05), except for that between the low- and moderate-myopia groups (p > 0.05). Conclusion: SSI decreased with increasing myopia and astigmatism in the Chinese participants. The SSI was significantly lower in high and ultra-high myopia, especially ultra-high myopia. These findings indicate that increased corneal elasticity may be related to the pathogenesis of high and ultra-high myopia.
Collapse
|
18
|
Gao R, Ren Y, Li S, Xu H, Lin X, McAlinden C, Ye J, Huang J, Yu J. Assessment of corneal biomechanics in anisometropia using Scheimpflug technology. Front Bioeng Biotechnol 2022; 10:994353. [PMID: 36338123 PMCID: PMC9632863 DOI: 10.3389/fbioe.2022.994353] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 09/12/2022] [Indexed: 10/24/2023] Open
Abstract
Purpose: To investigate the relationship between corneal biomechanical and ocular biometric parameters, and to explore biomechanical asymmetry between anisometropic eyes using the corneal visualization Scheimpflug technology device (Corvis ST). Methods: 180 anisometropic participants were included. Participants were divided into low (1.00≤△Spherical equivalent (SE) < 2.00D), moderate (2.00D≤△SE < 3.00D) and high (△SE ≥ 3.00D) anisometropic groups. Axial length (AL), keratometry, anterior chamber depth (ACD) and corneal biomechanical parameters were assessed using the OA-2000 biometer, Pentacam HR and Corvis ST, respectively. Results: The mean age of participants was 16.09 ± 5.64 years. Stress-Strain Index (SSI) was positively correlated with SE (r = 0.501, p < 0.001) and negatively correlated with AL (r = -0.436, p < 0.001). Some other Corvis ST parameters had weak correlation with SE or AL. Corneal biomechanical parameters except for time of first applanation (A1T), length of second applanation (A2L), deformation amplitude (DA), first applanation stiffness parameter (SPA1) and ambrosia relational thickness-horizontal (ARTh) were correlated with ametropic parameters (SE or AL) in multiple regression analyses. A1T, velocity of first applanation (A1V), time of second applanation (A2T), A2L, velocity of second applanation (A2V), corneal curvature radius at highest concavity (HCR), peak distance (PD), DA, deformation amplitude ratio max (2 mm) (DAR), SPA1, integrated radius (IR), and SSI showed significant differences between fellow eyes (p < 0.05). There was no significant difference in asymmetry of corneal biomechanics among the three groups (p > 0.05). Asymmetry of some biomechanical parameters had weak correlation with asymmetry of mean corneal curvatures and ACD. However, asymmetry of corneal biomechanical parameters was not correlated with asymmetry of SE or AL (p > 0.05). Conclusion: More myopic eyes had weaker biomechanical properties than the contralateral eye in anisometropia. However, a certain linear relationship between anisometropia and biomechanical asymmetry was not found.
Collapse
Affiliation(s)
- Rongrong Gao
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Yuecheng Ren
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Siheng Li
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Huilin Xu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xuanqiao Lin
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Colm McAlinden
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Swansea, United Kingdom
- Department of Ophthalmology, Royal Gwent Hospital, Aneurin Bevan University Health Board, Newport, United Kingdom
| | - Junming Ye
- Department Ophthalmology, Yiwu Central Hospital, Yiwu, Zhejiang, China
| | - Jinhai Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jinjin Yu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| |
Collapse
|
19
|
Chu Z, Ren Q, Chen M, Cheng L, Cheng H, Cui W, Bi W, Wu J. The relationship between axial length/corneal radius of curvature ratio and stress–strain index in myopic eyeballs: Using Corvis ST tonometry. Front Bioeng Biotechnol 2022; 10:939129. [PMID: 36046672 PMCID: PMC9420864 DOI: 10.3389/fbioe.2022.939129] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose: This study aimed to investigate the correlation of axial length/corneal radius of curvature ratio with stress–strain index (SSI).Methods: Retrospective analysis was conducted to compare the right eyes of those with high myopia (HM, n = 132; age and 10–48 years) with those without high myopia (NHM, n = 135; age and 7–48 years), where the baseline axial length, corneal radius of curvature ratio, and central corneal thickness were analyzed; the differences in two groups were compared; and the relationship of axial length and axial length/corneal radius of curvature ratio with SSI were explored.Results: Compared with AL < 26mm, SSI significantly decreased when AL ≥ 26 mm (p = 0.001), while there was no correlation with AL in the NHM group (r = -0.14, p = 0.12) or HM group (r = -0.09, p = 0.32). AL/CR was significantly associated with SSI in both the NHM (r = -0.4, p < 0.001) and HM (r = -0.18, p = 0.04) groups. In the NHM group, AL/CR was significantly associated with SSI (unstandardized beta = -0.514, se = 0.109, p < 0.001) with the adjustment of age and gender. Additionally, a significant association of SSI with AL/CR was also found after adjusting for age and gender (unstandardized beta = -0.258, se = 0.096, and p = 0.0082) in the HM group.Conclusion: SSI showed a significant negative correlation with AL/CR in patients without high myopia and in patients with high myopia. However, SSI exhibited no decrease with the worsening of myopia, but it gradually remained stable at a low level. The findings of this study validate, to some extent, the possibility of analyzing the dynamic changes in ocular wall stiffness during the development of myopia by measuring in vivo corneal biomechanical parameters.
Collapse
Affiliation(s)
- Zhe Chu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Qi Ren
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Meizhen Chen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University Guangzhou, Guangzhou, China
| | - Lu Cheng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University Guangzhou, Guangzhou, China
| | - Hao Cheng
- Department of Ophthalmology, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Wei Cui
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Wenjiao Bi
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Jie Wu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
- *Correspondence: Jie Wu,
| |
Collapse
|
20
|
Ozalp O, Atalay E. Biometric Determinants of Epithelial Thickness Profile Across a Wide Range of Refractive Errors. Ophthalmol Ther 2022; 11:1089-1100. [PMID: 35286628 PMCID: PMC9114216 DOI: 10.1007/s40123-022-00489-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 02/17/2022] [Indexed: 10/27/2022] Open
|