1
|
Song Y, Cen X, Sun D, Bálint K, Wang Y, Chen H, Gao S, Bíró I, Zhang M, Gu Y. Curved carbon-plated shoe may further reduce forefoot loads compared to flat plate during running. Sci Rep 2024; 14:13215. [PMID: 38851842 PMCID: PMC11162459 DOI: 10.1038/s41598-024-64177-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 06/05/2024] [Indexed: 06/10/2024] Open
Abstract
Using a curved carbon-fiber plate (CFP) in running shoes may offer notable performance benefit over flat plates, yet there is a lack of research exploring the influence of CFP geometry on internal foot loading during running. The objective of this study was to investigate the effects of CFP mechanical characteristics on forefoot biomechanics in terms of plantar pressure, bone stress distribution, and contact force transmission during a simulated impact peak moment in forefoot strike running. We employed a finite element model of the foot-shoe system, wherein various CFP configurations, including three stiffnesses (stiff, stiffer, and stiffest) and two shapes (flat plate (FCFP) and curved plate (CCFP)), were integrated into the shoe sole. Comparing the shoes with no CFP (NCFP) to those with CFP, we consistently observed a reduction in peak forefoot plantar pressure with increasing CFP stiffness. This decrease in pressure was even more notable in a CCFP demonstrating a further reduction in peak pressure ranging from 5.51 to 12.62%, compared to FCFP models. Both FCFP and CCFP designs had a negligible impact on reducing the maximum stress experienced by the 2nd and 3rd metatarsals. However, they greatly influenced the stress distribution in other metatarsal bones. These CFP designs seem to optimize the load transfer pathway, enabling a more uniform force transmission by mainly reducing contact force on the medial columns (the first three rays, measuring 0.333 times body weight for FCFP and 0.335 for CCFP in stiffest condition, compared to 0.373 in NCFP). We concluded that employing a curved CFP in running shoes could be more beneficial from an injury prevention perspective by inducing less peak pressure under the metatarsal heads while not worsening their stress state compared to flat plates.
Collapse
Affiliation(s)
- Yang Song
- Research Academy of Medicine Combining Sports, Ningbo No.2 Hospital, Ningbo, China
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Xuanzhen Cen
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
- Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Dong Sun
- Research Academy of Medicine Combining Sports, Ningbo No.2 Hospital, Ningbo, China
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Kovács Bálint
- Research Academy of Medicine Combining Sports, Ningbo No.2 Hospital, Ningbo, China
- Faculty of Sports Science, Ningbo University, Ningbo, China
- Department of Kinesiology, Hungarian University of Sports Science, Budapest, Hungary
| | - Yan Wang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Hairong Chen
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
- Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Shunxiang Gao
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - István Bíró
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
- Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Ming Zhang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Yaodong Gu
- Research Academy of Medicine Combining Sports, Ningbo No.2 Hospital, Ningbo, China.
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary.
- Faculty of Sports Science, Ningbo University, Ningbo, China.
| |
Collapse
|
2
|
Vijittrakarnrung C, Mongkolpichayaruk A, Limroongreungrat W, Chuckpaiwong B. Comparison of Foot Kinematics Between Normal Arch and Flexible Flatfoot Using the Oxford Foot Model: A Matched Case-Control Study. FOOT & ANKLE ORTHOPAEDICS 2024; 9:24730114241231245. [PMID: 38410138 PMCID: PMC10896060 DOI: 10.1177/24730114241231245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024] Open
Abstract
Background Symptomatic flexible flatfoot causes alterations in gait, but exactly how this condition affects the intersegmental motion of the foot during the gait cycle remains unclear. Previous studies have examined the kinematics, yielding inconsistent findings. Therefore, the objective of this study was to investigate how flexible flatfoot deformity, defined as Johnson and Strom classification staging II, affects the intersegmental motion of the foot during fast walking based on a comparison with the matched control group. Methods Eleven participants with symptomatic flexible flatfoot and 11 healthy matched control participants were recruited using a foot screening protocol incorporated through a foot physical examinations and radiographic measurements. All demographic characteristics exhibited comparable profiles between the groups. During controlled walking, kinematic outcomes pertaining to the hallux, hindfoot, forefoot, and tibia were collected using the multisegmental Oxford Foot Model. Results All spatiotemporal parameters were comparable between the groups. In comparison to the control group, individuals with symptomatic flexible flatfoot demonstrated increased hallux valgus and plantarflexion, increased forefoot abduction, heightened hindfoot eversion, and internal rotation. Notably, no significant major differences were observed in the tibia motion segment. Further, significant correlations were identified between static foot measurements and the extent of the maximum deviation observed during dynamic kinematic assessments. Conclusion Compared with age- and gender-matched controls, participants with symptomatic flexible flatfoot exhibited significant gait pattern deviations. A significant correlation also exists between static foot deformity measurements and dynamic kinematic deviations. Collectively, these findings have implications for developing targeted therapeutic interventions to address flexible flatfoot. Level of evidence Level III, diagnostic study.
Collapse
Affiliation(s)
| | | | | | - Bavornrit Chuckpaiwong
- College of Sports Science and Technology, Mahidol University, Nakhon Pathom, Thailand
- Orthopaedic Surgery and Rehabilitation department, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
3
|
Cheng ESW, Lai DKH, Mao YJ, Lee TTY, Lam WK, Cheung JCW, Wong DWC. Computational Biomechanics of Sleep: A Systematic Mapping Review. Bioengineering (Basel) 2023; 10:917. [PMID: 37627802 PMCID: PMC10451553 DOI: 10.3390/bioengineering10080917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/24/2023] [Accepted: 07/31/2023] [Indexed: 08/27/2023] Open
Abstract
Biomechanical studies play an important role in understanding the pathophysiology of sleep disorders and providing insights to maintain sleep health. Computational methods facilitate a versatile platform to analyze various biomechanical factors in silico, which would otherwise be difficult through in vivo experiments. The objective of this review is to examine and map the applications of computational biomechanics to sleep-related research topics, including sleep medicine and sleep ergonomics. A systematic search was conducted on PubMed, Scopus, and Web of Science. Research gaps were identified through data synthesis on variants, outcomes, and highlighted features, as well as evidence maps on basic modeling considerations and modeling components of the eligible studies. Twenty-seven studies (n = 27) were categorized into sleep ergonomics (n = 2 on pillow; n = 3 on mattress), sleep-related breathing disorders (n = 19 on obstructive sleep apnea), and sleep-related movement disorders (n = 3 on sleep bruxism). The effects of pillow height and mattress stiffness on spinal curvature were explored. Stress on the temporomandibular joint, and therefore its disorder, was the primary focus of investigations on sleep bruxism. Using finite element morphometry and fluid-structure interaction, studies on obstructive sleep apnea investigated the effects of anatomical variations, muscle activation of the tongue and soft palate, and gravitational direction on the collapse and blockade of the upper airway, in addition to the airflow pressure distribution. Model validation has been one of the greatest hurdles, while single-subject design and surrogate techniques have led to concerns about external validity. Future research might endeavor to reconstruct patient-specific models with patient-specific loading profiles in a larger cohort. Studies on sleep ergonomics research may pave the way for determining ideal spine curvature, in addition to simulating side-lying sleep postures. Sleep bruxism studies may analyze the accumulated dental damage and wear. Research on OSA treatments using computational approaches warrants further investigation.
Collapse
Affiliation(s)
- Ethan Shiu-Wang Cheng
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Department of Electronic and Information Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Derek Ka-Hei Lai
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Ye-Jiao Mao
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Timothy Tin-Yan Lee
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Wing-Kai Lam
- Sports Information and External Affairs Centre, Hong Kong Sports Institute, Hong Kong
| | - James Chung-Wai Cheung
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
4
|
Song Y, Cen X, Chen H, Sun D, Munivrana G, Bálint K, Bíró I, Gu Y. The influence of running shoe with different carbon-fiber plate designs on internal foot mechanics: A pilot computational analysis. J Biomech 2023; 153:111597. [PMID: 37126883 DOI: 10.1016/j.jbiomech.2023.111597] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 03/28/2023] [Accepted: 04/20/2023] [Indexed: 05/03/2023]
Abstract
A carbon-fiber plate (CFP) embedded into running shoes is a commonly applied method to improve running economy, but little is known in regard the effects of CFP design features on internal foot mechanics. This study aimed to explore how systematic changes in CFP geometrical variations (i.e., thickness and location) can alter plantar pressure and strain under the forefoot as well as metatarsal stress state through computational simulations. A foot-shoe finite element (FE) model was built and different CFP features including three thicknesses (1 mm, 2 mm, and 3 mm) and three placements (high-loaded (just below the insole), mid-loaded (in between the midsole), and low-loaded (just above the outsole)) were further modulated within the shoe sole. Simulations were conducted at the impact peak instant during forefoot strike running. Compared with the no-CFP shoe, peak plantar pressure and compressive strain under the forefoot consistently decreased when the CFP thickness increased, and the low-loaded conditions were found more effective (peak pressure decreased up to 31.91% and compressive strain decreased up to 18.61%). In terms of metatarsal stress, CFP designs resulted in varied effects and were dependent on their locations. Specifically, high-loaded CFP led to relatively higher peak metatarsal stress without the reduction trend as thickness increased (peak stress increased up to 12.91%), while low-loaded conditions showed a gradual reduction in peak stress, decreasing by 0.74%. Therefore, a low-loaded thicker CFP should be considered to achieve the pressure-relief effects of running shoes without the expense of increased metatarsal stress.
Collapse
Affiliation(s)
- Yang Song
- Faculty of Sports Science, Ningbo University, Ningbo, China; Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary; Faculty of Kinesiology, University of Split, Split, Croatia
| | - Xuanzhen Cen
- Faculty of Sports Science, Ningbo University, Ningbo, China; Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary; Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Hairong Chen
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Dong Sun
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | | | - Kovács Bálint
- Faculty of Sports Science, Ningbo University, Ningbo, China; Department of Kinesiology, Hungarian University of Sports Science, Budapest, Hungary
| | - István Bíró
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary; Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo, China.
| |
Collapse
|
5
|
Zhao Y, Zhong J, Wang Y, Chen Q, Yin J, Wang J, Zhao H, Li Y, Gong H, Huang W. Photocurable and elastic polyurethane based on polyether glycol with adjustable hardness for 3D printing customized flatfoot orthosis. Biomater Sci 2023; 11:1692-1703. [PMID: 36626200 DOI: 10.1039/d2bm01538b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Orthopedic insoles is the most commonly used nonsurgical treatment method for the flatfoot. Polyurethane (PU) plays a crucial role in the manufacturing of orthopedic insoles due to its high wear resistance and elastic recovery. However, preparing orthopedic insoles with adjustable hardness, high-accuracy, and matches the plantar morphology is challenging. Herein, a liquid crystal display (LCD) three-dimensional (3D) printer was used to prepare the customized arch-support insoles based on photo-curable and elastic polyurethane acrylate (PUA) composite resins. Two kinds of photo-curable polyurethanes (DL1000-PUA and DL2000-PUA) were successfully synthesized, and a series of fast-photocuring polyurethane acrylate (PUA) composite resins for photo-polymerization 3D printing were developed. The effects of different acrylate monomers on the Shore hardness, viscosity, and mechanical properties of the PUA composite resins were evaluated. The PUA-3-1 composite resin exhibited low viscosity, optimal hardness, and mechanical properties. A deviation analysis was conducted to assess the accuracy of printed insole. Furthermore, the stress conditions of the PUA composite resin and ethylene vinyl acetate (EVA) under the weight load of healthy adults were compared by finite element analysis (FEA) simulation. The results demonstrated that the stress of the PUA composite resin and EVA were 0.152 MPa and 0.285 MPa, and displacement were 0.051 mm and 3.449 mm, respectively. These results indicate that 3D-printed arch-support insole based on photocurable PUA composite resin are high-accuracy, and can reduce plantar pressure and prevent insoles premature deformation, which show great potential in the physiotherapeutic intervention for foot disorders.
Collapse
Affiliation(s)
- Yanyan Zhao
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Jing Zhong
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China. .,Dermatology Hospital, Southern Medical University, Guangzhou, 510091, China
| | - Yilin Wang
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Qiwei Chen
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Junfeiyang Yin
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Jiejie Wang
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Hong Zhao
- Guangdong Medical University, Zhanjiang, 524001, China
| | - Yanbing Li
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China.
| | - Haihuan Gong
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China. .,Department of Stomatology, Affiliated Hospital of Guangdong Medical University, Guangdong medical university, Zhanjiang, 524000, China
| | - Wenhua Huang
- Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515, China. .,Guangdong Medical University, Zhanjiang, 524001, China
| |
Collapse
|
6
|
Zhang LY, Liu QL, Yick KL, Yip J, Ng SP. Analysis of Diabetic Foot Deformation and Plantar Pressure Distribution of Women at Different Walking Speeds. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3688. [PMID: 36834384 PMCID: PMC9965013 DOI: 10.3390/ijerph20043688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/17/2023] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
Official guidelines state that suitable physical activity is recommended for patients with diabetes mellitus. However, since walking at a rapid pace could be associated with increased plantar pressure and potential foot pain, the footwear condition is particularly important for optimal foot protection in order to reduce the risk of tissue injury and ulceration of diabetic patients. This study aims to analyze foot deformation and plantar pressure distribution at three different walking speeds (slow, normal, and fast walking) in dynamic situations. The dynamic foot shape of 19 female diabetic patients at three walking speeds is obtained by using a novel 4D foot scanning system. Their plantar pressure distributions at the three walking speeds are also measured by using the Pedar in-shoe system. The pressure changes in the toes, metatarsal heads, medial and lateral midfoot, and heel areas are systematically investigated. Although a faster walking speed shows slightly larger foot measurements than the two other walking speeds, the difference is insignificant. The foot measurement changes at the forefoot and heel areas, such as the toe angles and heel width, are found to increase more readily than the measurements at the midfoot. The mean peak plantar pressure shows a significant increase at a faster walking speed with the exception of the midfoot, especially at the forefoot and heel areas. However, the pressure time integral decreases for all of the foot regions with an increase in walking speed. Suitable offloading devices are essential for diabetic patients, particularly during brisk walking. Design features such as medial arch support, wide toe box, and suitable insole material for specific area of the foot (such as polyurethane for forefoot area and ethylene-vinyl acetate for heel area) are essential for diabetic insole/footwear to provide optimal fit and offloading. The findings contribute to enhancing the understanding of foot shape deformation and plantar pressure changes during dynamic situations, thus facilitating the design of footwear/insoles with optimal fit, wear comfort, and foot protection for diabetic patients.
Collapse
Affiliation(s)
- Li-Ying Zhang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, Hong Kong, China
| | - Qi-Long Liu
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
| | - Kit-Lun Yick
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, Hong Kong, China
| | - Joanne Yip
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
| | - Sun-Pui Ng
- School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
7
|
Xu Z, Sun W, Li P, Wang Y, Wong DWC, Cheung JCW, Niu W, Zhang H, Ni M. Modified Ni-Nail and C-Nail systems for intra-articular fractures of the calcaneus: A biomechancial study. Injury 2022; 53:3904-3911. [PMID: 36182591 DOI: 10.1016/j.injury.2022.09.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/15/2022] [Accepted: 09/22/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVES We have proposed a novel intramedullary nail (Ni-Nail) by incorporating a sustentaculum tali screw to improve the fixation stability of minimally invasive treatment for calcaneal fractures. This study aimed to evaluate the biomechanical characters of the Ni-Nail system and compare it with traditional C-Nail system. METHODS A finite element model of a Sanders type-IIIAB calcaneal fracture was reconstructed and fixed using two intramedullary nail systems, which was validated by a cadaver study. A vertical loading of 700 N was applied to the subtalar joint surfaces, and 525 N Achilles tendon tension was applied to the superior border of the Achilles tuberosity. The von Mises stresses and fracture displacements of both fixation models were evaluated. RESULTS The maximum von Mises stress of the screws of Ni-Nail and C-Nail were 27.92 MPa and 57.42 MPa, respectively, while that of the main nail were 67.44 MPa and 53.01 MPa. In addition, the maximum fracture displacement of the Ni-Nail was larger than that of C-Nail by 15.6% (0.37 mm vs.0.32 mm). CONCLUSIONS Our static simulation analysis showed that both Ni-Nail and C-Nail demonstrated similar biomechanical stability for calcaneal fixation. The Ni-Nail features a simple structure that is easier to operate and less traumatizing. Future studies may consider to further evaluate the clinical effectiveness by clinical trials and follow-ups.
Collapse
Affiliation(s)
- Zihuan Xu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Wanju Sun
- Department of Orthopaedics, Shanghai Pudong New Area Peoples' Hospital, Shanghai 201299, China
| | - Pengfei Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Yongqin Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China
| | - James Chung-Wai Cheung
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China
| | - Wenxin Niu
- Yangzhi Rehabilitation Hospital, Tongji University School of Medicine, Shanghai 201619 China; Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
| | - Haowei Zhang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Ming Ni
- Department of Orthopaedics, Shanghai Pudong New Area Peoples' Hospital, Shanghai 201299, China; Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
| |
Collapse
|
8
|
The Effect of Concave-Side Intertransverse Ligament Laxity on the Stress of AIS Lumbar Spine Based on Finite Element Method. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 9:bioengineering9120724. [PMID: 36550930 PMCID: PMC9774201 DOI: 10.3390/bioengineering9120724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 11/10/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022]
Abstract
(1) Background: Scoliosis has the mechanical characteristic of asymmetric stress distribution, which is one of the reasons for the aggravation of scoliosis. Bracing therapy is the best treatment for AIS, but it is difficult and costly to operate. Is it possible to reduce pressure in the concave side by relaxing the ITL in the concave side of scoliosis, so as to improve the abnormal stress distribution of scoliosis? In this paper, a finite element method was used to simulate the effect of the relaxation of concave-side ITL on the stress of a lumbar spine with scoliosis, which provides some guidance for the treatment of scoliosis. (2) Methods: Using CT images of a patient with scoliosis whose Cobb Angle was 43° and Lordosis Angle was 45, a scoliosis lumbar was established, and Young's modulus of the ITL of the concave-side lumbar spine was reduced by 95% to simulate ligament relaxation. By comparing the stress condition of the model vertebral body with no ligament relaxation, the effect of concave-side ITL relaxation on the mechanical characteristics of scoliosis lumbar spine was explored. (3) Results: An effective and complete model of the lumbar spine was established. The concave ITL relaxed, which only had a great impact on the bending loads. After the ligament was relaxed, the stability of the spine was reduced. Stress concentration on the concave side of vertebrae and the IVD was aggravated. Under loads on the convex side, the maximum stress on the vertebral body and the IVD increased significantly, making lumbar vertebrae more vulnerable to injury. (4) Conclusions: Laxity of the ITL on the concave side of the AIS lumbar only affects the bending load. Laxity of the concave-side ligament will reduce the stability of the lumbar, aggravate the uneven stress distribution of scoliotic lumbar vertebrae, increase the risk of IVD injury, and be unfavorable for the scoliotic lumbar spine. Relaxation of the concave ITL alone is not an effective way to treat scoliosis.
Collapse
|
9
|
Yang Z, Cui C, Wan X, Zheng Z, Yan S, Liu H, Qu F, Zhang K. Design feature combinations effects of running shoe on plantar pressure during heel landing: A finite element analysis with Taguchi optimization approach. Front Bioeng Biotechnol 2022; 10:959842. [PMID: 36177186 PMCID: PMC9513060 DOI: 10.3389/fbioe.2022.959842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 08/15/2022] [Indexed: 11/28/2022] Open
Abstract
Large and repeated impacts on the heel during running are among the primary reasons behind runners’ injuries. Reducing plantar pressure can be conducive to reducing running injury and improving running performance and is primarily achieved by modifying the design parameters of running shoes. This study examines the effect of design parameters of running shoes (i.e., heel-cup, insole material, midsole material, and insole thickness) on landing peak plantar pressure and determines the combination of different parameters that optimize cushion effects by employing the Taguchi method. We developed the foot–shoe finite element (FE) model through reverse engineering. Model assembly with different design parameters was generated in accordance with the Taguchi method orthogonal table. The effectiveness of the model was verified using the static standing model in Ansys. The significance and contribution of different design parameters, and the optimal design to reduce plantar pressure during landing, were determined using the Taguchi method. In the descending order of percentage contribution was a conforming heel-cup (53.18%), insole material (25.89%), midsole material (7.81%), and insole thickness (2.69%). The more conforming heel-cup (p < 0.001) and softer insole (p = 0.001) reduced the heel pressure during landing impact. The optimal design of running shoe in this study was achieved with a latex insole, a 6 mm insole thickness, an Asker C-45 hardness midsole, and a 100% conforming heel-cup. The conforming heel-cup and the insole material significantly affected the peak plantar pressure during heel landing. The implementation of a custom conforming heel-cup is imperative for relieving high plantar pressure for long-distance heel-strike runners.
Collapse
Affiliation(s)
- Zihan Yang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
- School of Sport Sciences, Beijing Sport University, West Lafayette, IN, United States
- Fashion Accessory Art and Engineering College, Beijing Institute Of Fashion Technology, Beijing, China
| | - Chuyi Cui
- College of Health and Human Sciences, Purdue University, West Lafayette, IN, United States
| | - Xianglin Wan
- School of Sport Sciences, Beijing Sport University, West Lafayette, IN, United States
| | - Zhiyi Zheng
- Anta Sports Science Laboratory, Xiamen, China
| | - Songhua Yan
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Hui Liu
- School of Sport Sciences, Beijing Sport University, West Lafayette, IN, United States
- China Institute of Sport and Health Science, Beijing Sport University, Beijing, China
| | - Feng Qu
- School of Sport Sciences, Beijing Sport University, West Lafayette, IN, United States
| | - Kuan Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
- *Correspondence: Kuan Zhang,
| |
Collapse
|