1
|
Bari T, Al Mamun MA, Toet H, Rathinasamy V, Larkins JA, Beddoe T, Spithill TW, Piedrafita D, Greenhill AR. Evaluation of LAMP for Fasciola hepatica detection from faecal samples of experimentally and naturally infected cattle. Vet Parasitol 2024; 327:110132. [PMID: 38280252 DOI: 10.1016/j.vetpar.2024.110132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 01/16/2024] [Accepted: 01/16/2024] [Indexed: 01/29/2024]
Abstract
Fasciola hepatica causes liver fluke disease in production animals and humans worldwide. Faecal egg counts (FEC) are the most common diagnostic tool for the diagnosis of liver fluke disease. However, FEC has low sensitivity and is often unreliable for the detection of patent infection. In this study, loop-mediated isothermal amplification (LAMP) was optimised and evaluated for the detection of Fasciola hepatica infection, with the aim of increased sensitivity and making it suitable for on-farm application. LAMP was initially conducted under laboratory conditions, optimised to enable visual detection using calcein dye. DNA extraction based on bead-beating was developed to enable on-farm application. LAMP results were compared to FEC and polymerase chain reaction (PCR). Under laboratory conditions, LAMP was conducted using two incubation methods: a conventional PCR thermocycler and a field-deployable LAMP instrument. When compared to a 'rigorous' FEC protocol consisting of multiple counts using a comparatively large volume of faeces and with infection confirmed post-mortem, LAMP was highly sensitive and specific (using silica membrane DNA extraction sensitivity 88 %, specificity 100 %; using sieving and beat-beating DNA extraction sensitivity 98.9 %, specificity 100 %). When applied on-farm, LAMP was compared to conventional FEC, which suggested high sensitivity but low specificity (sensitivity 97 %, specificity 37.5 %). However, further analysis, comparing field LAMP results to laboratory PCR, suggested that the low specificity was likely the outcome of the inability of conventional FEC to detect all true F. hepatica positive samples. Based on the high sensitivity and specificity of LAMP compared to a 'rigorous' FEC protocol and its ability to be used in field settings, the study demonstrates the potential of LAMP for diagnosing F. hepatica infection in agriculture.
Collapse
Affiliation(s)
- Tanjina Bari
- Institute of Innovation, Science and Sustainability (IISS), Federation University, Australia
| | - Md Abdullah Al Mamun
- Faculty of Medicine, Nursing and Health Sciences, Monash University, VIC, Australia; Department of Parasitology, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Hayley Toet
- Department of Animal, Plant and Soil Science, Centre for AgriBioscience, La Trobe University, Bundoora, Australia
| | - Vignesh Rathinasamy
- Department of Animal, Plant and Soil Science, Centre for AgriBioscience, La Trobe University, Bundoora, Australia; Australian Institute of Tropical Health and Medicine, James Cook University, Cairns, Queensland, Australia
| | - Jo-Ann Larkins
- Institute of Innovation, Science and Sustainability (IISS), Federation University, Australia
| | - Travis Beddoe
- Department of Animal, Plant and Soil Science, Centre for AgriBioscience, La Trobe University, Bundoora, Australia
| | - Terry W Spithill
- Department of Animal, Plant and Soil Science, Centre for AgriBioscience, La Trobe University, Bundoora, Australia
| | - David Piedrafita
- Institute of Innovation, Science and Sustainability (IISS), Federation University, Australia
| | - Andrew R Greenhill
- Institute of Innovation, Science and Sustainability (IISS), Federation University, Australia; Department of Animal, Plant and Soil Science, Centre for AgriBioscience, La Trobe University, Bundoora, Australia.
| |
Collapse
|
2
|
Zhang Y, Luck AN, Tanner NA. Isothermal amplification of long DNA fragments at low temperature by improved strand displacement amplification. Biotechniques 2024; 76:255-262. [PMID: 38546276 DOI: 10.2144/btn-2024-0012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Accepted: 03/22/2024] [Indexed: 07/26/2024] Open
Abstract
Strand displacement amplification (SDA) is an isothermal amplification technique wherein amplification of a nucleic acid is initiated by nicking enzyme activity at sites flanking the target. Diagnostic SDA is very fast but requires precise optimization and is limited to very short amplicons. Here we report an enhanced approach by addition of single-stranded DNA binding protein, crowding agents and dUTP to enable amplification of kilobase-length products at low temperatures. Additionally, we pair this improved SDA with a novel carryover contamination prevention, eliminating amplifiable DNA at the end of the reaction to reduce contamination risk. Taken together these developments increase the utility and versatility of SDA, broadening the reach of this powerful but uncommonly used method.
Collapse
Affiliation(s)
- Yinhua Zhang
- New England Biolabs, 240 County Road, Ipswich, MA 01938, USA
| | - Ashley N Luck
- New England Biolabs, 240 County Road, Ipswich, MA 01938, USA
| | - Nathan A Tanner
- New England Biolabs, 240 County Road, Ipswich, MA 01938, USA
| |
Collapse
|
3
|
Li W, Ma X, Yong YC, Liu G, Yang Z. Review of paper-based microfluidic analytical devices for in-field testing of pathogens. Anal Chim Acta 2023; 1278:341614. [PMID: 37709421 DOI: 10.1016/j.aca.2023.341614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 09/16/2023]
Abstract
Pathogens cause various infectious diseases and high morbidity and mortality which is a global public health threat. The highly sensitive and specific detection is of significant importance for the effective treatment and intervention to minimise the impact. However, conventional detection methods including culture and molecular method gravely depend on expensive equipment and well-trained skilled personnel, limiting in the laboratory. It remains challenging to adapt in resource-limiting areas, e.g., low and middle-income countries (LMICs). To this end, low-cost, rapid, and sensitive detection tools with the capability of field testing e.g., a portable device for identification and quantification of pathogens, has attracted increasing attentions. Recently, paper-based microfluidic analytical devices (μPADs) have shown a promising tool for rapid and on-site diagnosis, providing a cost-effective and sensitive analytical approach for pathogens detection. The fast turn-round data collection may also contribute to better understanding of the risks and insights on mitigation method. In this paper, critical developments of μPADs for in-field detection of pathogens both for clinical diagnostics and environmental surveillance are reviewed. The future development, and challenges of μPADs for rapid and onsite detection of pathogens are discussed, including using the cross-disciplinary development with, emerging techniques such as deep learning and Internet of Things (IoT).
Collapse
Affiliation(s)
- Wenliang Li
- School of Water, Energy and Environment, Cranfield University, Cranfield, MK43 0AL, Bedford, United Kingdom
| | - Xuanye Ma
- School of Water, Energy and Environment, Cranfield University, Cranfield, MK43 0AL, Bedford, United Kingdom
| | - Yang-Chun Yong
- Biofuels Institute, Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment, School of Emergency Management & School of Environment and Safety Engineering, Zhenjiang, 212013, Jiangsu Province, China
| | - Guozhen Liu
- School of Medicine, The Chinese University of Hong Kong, Shenzhen, 518172, China
| | - Zhugen Yang
- School of Water, Energy and Environment, Cranfield University, Cranfield, MK43 0AL, Bedford, United Kingdom.
| |
Collapse
|
4
|
Borah Slater K, Ahmad M, Poirier A, Stott A, Siedler BS, Brownsword M, Mehat J, Urbaniec J, Locker N, Zhao Y, La Ragione R, Silva SRP, McFadden J. Development of a loop-mediated isothermal amplification (LAMP)-based electrochemical test for rapid detection of SARS-CoV-2. iScience 2023; 26:107570. [PMID: 37664622 PMCID: PMC10470312 DOI: 10.1016/j.isci.2023.107570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/10/2023] [Accepted: 08/07/2023] [Indexed: 09/05/2023] Open
Abstract
Rapid, reliable, sensitive, portable, and accurate diagnostics are required to control disease outbreaks such as COVID-19 that pose an immense burden on human health and the global economy. Here we developed a loop-mediated isothermal amplification (LAMP)-based electrochemical test for the detection of SARS-CoV-2 that causes COVID-19. The test is based on the oxidation-reduction reaction between pyrophosphates (generated from positive LAMP reaction) and molybdate that is detected by cyclic voltammetry using inexpensive and disposable carbon screen printed electrodes. Our test showed higher sensitivity (detecting as low as 5.29 RNA copies/μL) compared to the conventional fluorescent reverse transcriptase (RT)-LAMP. We validated our tests using human serum and saliva spiked with SARS-CoV-2 RNA and clinical (saliva and nasal-pharyngeal) swab samples demonstrating 100% specificity and 93.33% sensitivity. Our assay provides a rapid, specific, and sensitive test with an electrochemical readout in less than 45 min that could be adapted for point-of-care settings.
Collapse
Affiliation(s)
- Khushboo Borah Slater
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Muhammad Ahmad
- Advanced Technology Institute, University of Surrey, Guildford GU2 7XH, UK
| | - Aurore Poirier
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
- School of Veterinary Medicine, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7AL, UK
| | - Ash Stott
- Advanced Technology Institute, University of Surrey, Guildford GU2 7XH, UK
| | - Bianca Sica Siedler
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Matthew Brownsword
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Jai Mehat
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Joanna Urbaniec
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Nicolas Locker
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| | - Yunlong Zhao
- Advanced Technology Institute, University of Surrey, Guildford GU2 7XH, UK
| | - Roberto La Ragione
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
- School of Veterinary Medicine, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7AL, UK
| | - S. Ravi P. Silva
- Advanced Technology Institute, University of Surrey, Guildford GU2 7XH, UK
| | - Johnjoe McFadden
- School of Biosciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
| |
Collapse
|
5
|
Gao L, Li L, Fang B, Fang Z, Xiang Y, Zhang M, Zhou J, Song H, Chen L, Li T, Xiao H, Wan R, Jiang Y, Peng H. Carryover Contamination-Controlled Amplicon Sequencing Workflow for Accurate Qualitative and Quantitative Detection of Pathogens: a Case Study on SARS-CoV-2. Microbiol Spectr 2023; 11:e0020623. [PMID: 37098913 PMCID: PMC10269707 DOI: 10.1128/spectrum.00206-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 04/02/2023] [Indexed: 04/27/2023] Open
Abstract
Carryover contamination during amplicon sequencing workflow (AMP-Seq) put the accuracy of the high-throughput detection for pathogens at risk. The purpose of this study is to develop a carryover contaminations-controlled AMP-Seq (ccAMP-Seq) workflow to enable accurate qualitative and quantitative detection for pathogens. By using the AMP-Seq workflow to detect SARS-CoV-2, Aerosols, reagents and pipettes were identified as potential sources of contaminations and ccAMP-Seq was then developed. ccAMP-Seq used filter tips and physically isolation of experimental steps to avoid cross contamination, synthetic DNA spike-ins to compete with contaminations and quantify SARS-CoV-2, dUTP/uracil DNA glycosylase system to digest the carryover contaminations, and a new data analysis procedure to remove the sequencing reads from contaminations. Compared to AMP-Seq, the contamination level of ccAMP-Seq was at least 22-folds lower and the detection limit was also about an order of magnitude lower-as low as one copy/reaction. By testing the dilution series of SARS-CoV-2 nucleic acid standard, ccAMP-Seq showed 100% sensitivity and specificity. The high sensitivity of ccAMP-Seq was further confirmed by the detection of SARS-CoV-2 from 62 clinical samples. The consistency between qPCR and ccAMP-Seq was 100% for all the 53 qPCR-positive clinical samples. Seven qPCR-negative clinical samples were found to be positive by ccAMP-Seq, which was confirmed by extra qPCR tests on subsequent samples from the same patients. This study presents a carryover contamination-controlled, accurate qualitative and quantitative amplicon sequencing workflow that addresses the critical problem of pathogen detection for infectious diseases. IMPORTANCE Accuracy, a key indicator of pathogen detection technology, is compromised by carryover contamination in the amplicon sequencing workflow. Taking the detection of SARS-CoV-2 as case, this study presents a new carryover contamination-controlled amplicon sequencing workflow. The new workflow significantly reduces the degree of contamination in the workflow, thereby significantly improving the accuracy and sensitivity of the SARS-CoV-2 detection and empowering the ability of quantitative detection. More importantly, the use of the new workflow is simple and economical. Therefore, the results of this study can be easily applied to other microorganism, which has great significance for improving the detection level of microorganism.
Collapse
Affiliation(s)
- Lifen Gao
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Lun Li
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Bin Fang
- Hubei Provincial Centers for Disease Control and Prevention, Wuhan, Hubei, People’s Republic of China
| | - Zhiwei Fang
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Yanghai Xiang
- Yueyang Central Hospital, Yueyang, Hunan, People’s Republic of China
| | - Min Zhang
- Yueyang Central Hospital, Yueyang, Hunan, People’s Republic of China
| | - Junfei Zhou
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Huiyin Song
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Lihong Chen
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Tiantian Li
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Huafeng Xiao
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Renjing Wan
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Yongzhong Jiang
- Hubei Provincial Centers for Disease Control and Prevention, Wuhan, Hubei, People’s Republic of China
| | - Hai Peng
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
- Mingliao Biotechnology Co., Ltd., Wuhan, Hubei, People’s Republic of China
| |
Collapse
|
6
|
Development and Validation of Rapid Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification for Detection of Rift Valley Fever Virus. Adv Virol 2023; 2023:1863980. [PMID: 36755743 PMCID: PMC9902148 DOI: 10.1155/2023/1863980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/22/2022] [Accepted: 01/20/2023] [Indexed: 01/31/2023] Open
Abstract
Rift Valley fever virus (RVFV) is a high-priority zoonotic pathogen with the ability to cause massive loss during its outbreak within a very short period of time. Lack of a highly sensitive, instant reading diagnostic method for RVFV, which is more suitable for on-site testing, is a big gap that needs to be addressed. The aim of this study was to develop a novel one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the rapid detection of RVFV. To achieve this, the selected RVFV M segment nucleotide sequences were aligned using Multiple Sequence Comparison by Log-Expectation (MUSCLE) software in MEGA11 version 11.0.11 program to identify conserved regions. A 211 pb sequence was identified and six different primers to amplify it were designed using NEB LAMP Primer design tool version 1.1.0. The specificity of the designed primers was tested using primer BLAST, and a primer set, specific to RVFV and able to form a loop, was selected. In this study, we developed a single-tube test based on calorimetric RT-LAMP that enabled the visual detection of RVFV within 30 minutes at 65°C. Diagnostic sensitivity and specificity of the newly developed kit were compared with RVFV qRT-PCR, using total RNA samples extracted from 118 blood samples. The colorimetric RT-LAMP assay had a sensitivity of 98.36% and a specificity of 96.49%. The developed RT-LAMP was found to be tenfold more sensitive compared to the RVFV qRT-PCR assay commonly used in the confirmatory diagnosis of RVFV.
Collapse
|
7
|
Van Ngoc H, Quyen TL, Vinayaka AC, Bang DD, Wolff A. Point-of-care system for rapid real-time detection of SARS-CoV-2 virus based on commercially available Arduino platforms. Front Bioeng Biotechnol 2022; 10:917573. [PMID: 35992344 PMCID: PMC9385952 DOI: 10.3389/fbioe.2022.917573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 06/27/2022] [Indexed: 11/13/2022] Open
Abstract
The COVID-19 pandemic emphasized the importance of rapid, portable, and on-site testing technologies necessary for resource-limited settings for effective testing and screening to reduce spreading of the infection. Realizing this, we developed a fluorescence-based point-of-care (fPOC) detection system with real-time reverse transcriptase loop-mediated isothermal amplification for rapid and quantitative detection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. The system is built based on the Arduino platform compatible with commercially available open-source hardware-software and off-the-shelf electronic components. The fPOC system comprises of three main components: 1) an instrument with integrated heaters, 2) optical detection components, and 3) an injection-molded polymeric cartridge. The system was tested and experimentally proved to be able to use for fast detection of the SARS-CoV-2 virus in real-time in less than 30 min. Preliminary results of testing the performance of the fPOC revealed that the fPOC could detect the SARS-CoV-2 virus at a limit of detection (LOD50%) at two to three copies/microliter (15.36 copies/reaction), which was comparable to reactions run on a standard commercial thermocycler. The performance of the fPOC was evaluated with 12 SARS-CoV-2 clinical throat swab samples that included seven positive and five negative samples, as confirmed by reverse transcription-polymerase chain reaction. The fPOC showed 100% agreement with the commercial thermocycler. This simple design of the fPOC system demonstrates the potential to greatly enhance the practical applicability to develop a totally integrated point-of-care system for rapid on-site screening of the SARS-CoV-2 virus in the management of the pandemic.
Collapse
Affiliation(s)
- Huynh Van Ngoc
- BioLabChip Group, Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
| | - Than Linh Quyen
- BioLabChip Group, Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
| | - Aaydha Chidambara Vinayaka
- Laboratory of Applied Micro and Nanotechnology (LAMINATE), Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
| | - Dang Duong Bang
- Laboratory of Applied Micro and Nanotechnology (LAMINATE), Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
| | - Anders Wolff
- BioLabChip Group, Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
| |
Collapse
|