1
|
Yu L, Delgado J, De Mezerville R. Thermal mapping: Assessing the optimal sites for temperature measurement in the human body and emerging technologies. Physiol Rep 2024; 12:e16155. [PMID: 39039617 PMCID: PMC11262999 DOI: 10.14814/phy2.16155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 07/09/2024] [Accepted: 07/09/2024] [Indexed: 07/24/2024] Open
Abstract
Numerous body locations have been utilized to obtain an accurate body temperature. While some are commonly used, their accuracy, response time, invasiveness varies greatly, and determines their potential clinical and/or research use. This review discusses human body temperature locations, their accuracy, ease of use, advantages, and drawbacks. We explain the concept of core body temperature and which of the locations achieve the best correlation to this temperature. The body locations include axilla, oral cavity, rectum, digestive and urinary tracts, skin, tympanic, nasopharynx, esophagus, and pulmonary artery. The review also discusses the latest temperature technologies, heat-flux technology and telemetric ingestible temperature pills, and the body locations used to validate these devices. Rectal and esophageal measurements are the most frequently used.
Collapse
Affiliation(s)
- L Yu
- Research, Development and Innovation, Establishment Labs, Coyol, Alajuela, Costa Rica
| | - J Delgado
- Research, Development and Innovation, Establishment Labs, Coyol, Alajuela, Costa Rica
| | - R De Mezerville
- Research, Development and Innovation, Establishment Labs, Coyol, Alajuela, Costa Rica
| |
Collapse
|
2
|
Bothe TL, Gunga HC, Pilz N, Heinz V, Opatz OS. Relativistic aspects of physiology: Expanding our understanding of conventional control loops. Acta Physiol (Oxf) 2023; 239:e14064. [PMID: 37964669 DOI: 10.1111/apha.14064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 11/03/2023] [Indexed: 11/16/2023]
Affiliation(s)
- T L Bothe
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - H C Gunga
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - N Pilz
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
- Institute of Translational Physiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - V Heinz
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - O S Opatz
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
3
|
Eisenkraft A, Goldstein N, Fons M, Tabi M, Sherman AD, Ben Ishay A, Merin R, Nachman D. Comparing body temperature measurements using the double sensor method within a wearable device with oral and core body temperature measurements using medical grade thermometers-a short report. Front Physiol 2023; 14:1279314. [PMID: 38033330 PMCID: PMC10685445 DOI: 10.3389/fphys.2023.1279314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/02/2023] [Indexed: 12/02/2023] Open
Abstract
Introduction: Body temperature is essential for diagnosing, managing, and following multiple medical conditions. There are several methods and devices to measure body temperature, but most do not allow continuous and prolonged measurement of body temperature. Noninvasive skin temperature sensor combined with a heat flux sensor, also known as the "double sensor" technique, is becoming a valuable and simple method for frequently monitoring body temperature. Methods: Body temperature measurements using the "double sensor" method in a wearable monitoring device were compared with oral and core body temperature measurements using medical grade thermometers, analyzing data from two prospective clinical trials of different clinical scenarios. One study included 45 hospitalized COVID-19 patients in which oral measurements were taken using a hand-held device, and the second included 18 post-cardiac surgery patients in which rectal measurements were taken using a rectal probe. Results: In study 1, Bland-Altman analysis showed a bias of -0.04°C [0.34-(-0.43)°C, 95% LOA] with a correlation of 99.4% (p < 0.001). In study 2, Bland-Altman analysis showed a bias of 0.0°C [0.27-(-0.28)°C, 95% LOA], and the correlation was 99.3% (p < 0.001). In both studies, stratifying patients based on BMI and skin tone showed high accordance in all sub-groups. Discussion: The wearable monitor showed high correlation with oral and core body temperature measurements in different clinical scenarios.
Collapse
Affiliation(s)
- Arik Eisenkraft
- Institute for Research in Military Medicine, Faculty of Medicine, The Hebrew University of Jerusalem and the Israel Defense Force Medical Corps, Jerusalem, Israel
- Biobeat Technologies Ltd., Petah Tikva, Israel
| | | | - Meir Fons
- Biobeat Technologies Ltd., Petah Tikva, Israel
| | | | | | | | - Roei Merin
- Biobeat Technologies Ltd., Petah Tikva, Israel
| | - Dean Nachman
- Institute for Research in Military Medicine, Faculty of Medicine, The Hebrew University of Jerusalem and the Israel Defense Force Medical Corps, Jerusalem, Israel
- Heart Institute, Hadassah Medical Center, The Hebrew University of Jerusalem, Jerusalem, Israel
| |
Collapse
|
4
|
Ekers T, Adamson N, Wells A, Presneill J. A pilot study of agreement between noninvasive thermometers and the core temperature of postoperative cardiothoracic surgical patients. Aust Crit Care 2023; 36:782-786. [PMID: 36123238 DOI: 10.1016/j.aucc.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 08/07/2022] [Accepted: 08/12/2022] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE Reliable and accurate temperature assessment is fundamental for clinical monitoring; noninvasive thermometers of various designs are widely used in intensive care units, sometimes without a specific assessment of their suitability and interchangeability. This study evaluated agreement of four noninvasive thermometers with a pulmonary artery catheter temperature. METHODS This prospective method comparison study was conducted in an Australian adult intensive care unit. One hundred postoperative adult cardiothoracic surgery patients who had a pulmonary artery catheter (Edwards Lifescience) in situ were identified. The temperature reading from the pulmonary artery catheter was compared to contemporaneous measurements returned by four different thermometers-temporal Artery (TA, Technimed), Per Axilla (Axilla, Welch Allyn), Tympanic (Tymp, Covidien), and the NexTemp® (NEXT, Medical Indicators [used per axilla]). The time required to obtain each noninvasive temperature measurement was recorded. RESULTS Agreements between each noninvasive temperature and the pulmonary artery catheter standard were assessed using summary statistics and the Bland-Altman method comparison approach. A clinically acceptable maximum difference from the standard was defined as ±0.5 °C. Temperature agreement with the pulmonary artery standard (mean difference °C [95% limits of agreement °C]) was greatest for Tymp (-0.20 [-0.92 to 0.52]), intermediate for AXILLA (-0.37 [-1.3 to 0.59]) and NEXT (-0.71 [-1.7 to 0.27]), and least for TA (-0.60 [-2.0 to 0.81]). The proportion of measurements within ±0.5 °C of the standard were TYMP (81%), AXILLA (63%), TA (45%), and NEXT (30%). The time to obtain measurements varied, with the Tymp and TA estimates immediate, the AXILLA a mean of 40 s (standard deviation = 11 s), while NEXT results were at the manufacturer-recommended 3-min point. CONCLUSIONS Tympanic thermometers showed closest agreement with the pulmonary artery standard. Deviations by more than 0.5 °C from that standard were relatively common with all noninvasive devices.
Collapse
Affiliation(s)
- Tristan Ekers
- Intensive Care Unit, Royal Melbourne Hospital, Melbourne, Victoria, Australia, 3050.
| | - Nathaniel Adamson
- Intensive Care Unit, Gold Coast University Hospital, Southport, Queensland, Australia, 4215.
| | - Alison Wells
- Intensive Care Unit, Royal Melbourne Hospital, Melbourne, Victoria, Australia, 3050.
| | - Jeffrey Presneill
- Intensive Care Unit, Royal Melbourne Hospital, Melbourne, Victoria, Australia, 3050.
| |
Collapse
|
5
|
Eisenkraft A, Goldstein N, Merin R, Fons M, Ishay AB, Nachman D, Gepner Y. Developing a real-time detection tool and an early warning score using a continuous wearable multi-parameter monitor. Front Physiol 2023; 14:1138647. [PMID: 37064911 PMCID: PMC10090377 DOI: 10.3389/fphys.2023.1138647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 03/20/2023] [Indexed: 03/31/2023] Open
Abstract
Background: Currently-used tools for early recognition of clinical deterioration have high sensitivity, but with low specificity and are based on infrequent measurements. We aimed to develop a pre-symptomatic and real-time detection and warning tool for potential patients’ deterioration based on multi-parameter real-time warning score (MPRT-WS).Methods: A total of more than 2 million measurements were collected, pooled, and analyzed from 521 participants, of which 361 were patients in general wards defined at high-risk for deterioration and 160 were healthy participants allocation as controls. The risk score stratification was based on cutoffs of multiple physiological parameters predefined by a panel of specialists, and included heart rate, blood oxygen saturation (SpO2), respiratory rate, cuffless systolic and diastolic blood pressure (SBP and DBP), body temperature, stroke volume (SV), cardiac output, and systemic vascular resistance (SVR), recorded every 5 min for a period of up to 72 h. The data was used to define the various risk levels of a real-time detection and warning tool, comparing it with the clinically-used National Early Warning Score (NEWS).Results: When comparing risk levels among patients using both tools, 92.6%, 6.1%, and 1.3% of the readings were defined as “Low”, “Medium”, and “High” risk with NEWS, and 92.9%, 6.4%, and 0.7%, respectively, with MPRT-WS (p = 0.863 between tools). Among the 39 patients that deteriorated, 30 patients received ‘High’ or ‘Urgent’ using the MPRT-WS (42.7 ± 49.1 h before they deteriorated), and only 6 received ‘High’ score using the NEWS. The main abnormal vitals for the MPRT-WS were SpO2, SBP, and SV for the “Urgent” risk level, DBP, SVR, and SBP for the “High” risk level, and DBP, SpO2, and SVR for the “Medium” risk level.Conclusion: As the new detection and warning tool is based on highly-frequent monitoring capabilities, it provides medical teams with timely alerts of pre-symptomatic and real-time deterioration.
Collapse
Affiliation(s)
- Arik Eisenkraft
- Biobeat Technologies Ltd., Petach Tikva, Israel
- Faculty of Medicine, Institute for Research in Military Medicine, The Hebrew University of Jerusalem, Israel Defense Force Medical Corps, Jerusalem, Israel
| | | | - Roei Merin
- Biobeat Technologies Ltd., Petach Tikva, Israel
| | - Meir Fons
- Biobeat Technologies Ltd., Petach Tikva, Israel
| | | | - Dean Nachman
- Faculty of Medicine, Institute for Research in Military Medicine, The Hebrew University of Jerusalem, Israel Defense Force Medical Corps, Jerusalem, Israel
- Heart Institute, Hadassah Medical Center, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Yftach Gepner
- Department of Epidemiology and Preventive Medicine, School of Public Health, Sackler Faculty of Medicine and Sylvan Adams Sports Institute, Tel Aviv University, Tel Aviv, Israel
- *Correspondence: Yftach Gepner,
| |
Collapse
|
6
|
Bräuer A, Fazliu A, Brandes IF, Vollnhals F, Grote R, Menzel M. Evaluation of the Temple Touch Pro™ noninvasive core-temperature monitoring system in 100 adults under general anesthesia: a prospective comparison with esophageal temperature. J Clin Monit Comput 2023; 37:29-36. [PMID: 35377051 PMCID: PMC9852212 DOI: 10.1007/s10877-022-00851-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 03/16/2022] [Indexed: 01/24/2023]
Abstract
Perioperative hypothermia is still common and has relevant complication for the patient. An effective perioperative thermal management requires essentially an accurate method to measure core temperature. So far, only one study has investigated the new Temple Touch Pro™ (Medisim Ltd., Beit-Shemesh, Israel). during anesthesia Therefore, we assessed the agreement between the Temple Touch Pro™ thermometer (TTP) and distal esophageal temperature (TEso) in a second study. After approval by the local ethics committee we studied 100 adult patients undergoing surgery with general anesthesia. Before induction of anesthesia the TTP sensor unit was attached to the skin above the temporal artery. After induction of anesthesia an esophageal temperature probe was placed in the distal esophagus. Recordings started 10 min after placement of the esophageal temperature probe to allow adequate warming of the probes. Pairs of temperature values were documented in five-minute intervals until emergence of anesthesia. Accuracy of the two methods was assessed by Bland-Altman comparisons of differences with multiple measurements. Core temperatures obtained with the TTP in adults showed a mean bias of -0.04 °C with 95% limits of agreement within - 0.99 °C to + 0.91 °C compared to an esophageal temperature probe. We consider the TTP as a reasonable tool for perioperative temperature monitoring. It is not accurate enough to be used as a reference method in scientific studies, but may be a useful tool especially for conscious patients undergoing neuraxial anesthesia or regional anesthesia with sedation. Trial registration This study was registered in the German Clinical Trials Register (DRKS-ID: 00024050), day of registration 12/01/2021.
Collapse
Affiliation(s)
- Anselm Bräuer
- Department of Anesthesiology, University Medical Centre Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
| | - Albulena Fazliu
- Department of Anesthesiology, University Medical Centre Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Ivo F Brandes
- Department of Anesthesiology, University Medical Centre Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Falk Vollnhals
- Department of Anesthesiology, Emergency Medicine, Intensive Care Medicine and Pain Therapy, Klinikum Wolfsburg, Wolfsburg, Germany
| | - Rolf Grote
- Department of Anesthesiology, University Medical Centre Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.,Department of Anesthesiology, Emergency Medicine, Intensive Care Medicine and Pain Therapy, Klinikum Wolfsburg, Wolfsburg, Germany
| | - Matthias Menzel
- Department of Anesthesiology, University Medical Centre Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.,Department of Anesthesiology, Emergency Medicine, Intensive Care Medicine and Pain Therapy, Klinikum Wolfsburg, Wolfsburg, Germany
| |
Collapse
|
7
|
Cha Y, Seo B, Chung M, Kim BSY, Choi W, Park W. Skin-Inspired Thermometer Enabling Contact-Independent Temperature Sensation via a Seebeck-Resistive Bimodal System. ACS APPLIED MATERIALS & INTERFACES 2022; 14:17920-17926. [PMID: 35384656 DOI: 10.1021/acsami.1c24420] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Tactile sensation is a powerful method for probing the temperature of an arbitrary object due to its intuitive operating mechanism. However, the disruptive interface commonly formed between the thermometer and the object gives rise to thermal contact resistance, which is the primary source of measurement inaccuracy. Here, we develop a bioinspired bimodal temperature sensor exhibiting robust measurement accuracy by precisely decoupling contact resistance from the associated thermal circuit. In our sensors, a micropatterned resistive thermometer is placed underneath a thermoelectric heat fluxmeter, which resembles thermoreceptors located in human biomembranes. The object temperature is probed by modulating the thermometer temperature within the sensor system and precisely extrapolating the zero-heat flux point of the Seebeck voltage developed across the fluxmeter. At this zero-heat flux point, the object and thermometer temperatures coincide with each other regardless of the contact resistance formed at the fluxmeter-object interface. An experimental study shows that our sensors display excellent measurement accuracy within ∼0.5 K over a wide range of contact resistance values. Our work opens up new avenues for highly sensitive tactile thermal sensation in thermal haptics, medical devices, and robotics if combined with flexible devices.
Collapse
Affiliation(s)
- Youngsun Cha
- School of Mechanical Engineering, Korea University, Seoul 02841, South Korea
| | - Byungseok Seo
- School of Mechanical Engineering, Korea University, Seoul 02841, South Korea
| | - Myoungkil Chung
- Division of Mechanical Systems, Sookmyung Women's University, Seoul 04310, South Korea
| | - Brian S Y Kim
- Department of Mechanical Engineering, Columbia University, New York, New York 10034 United States
| | - Wonjoon Choi
- School of Mechanical Engineering, Korea University, Seoul 02841, South Korea
| | - Woosung Park
- Division of Mechanical Systems, Sookmyung Women's University, Seoul 04310, South Korea
- Institute of Advanced Material Systems, Sookmyung Women's University, Seoul 04310, South Korea
| |
Collapse
|
8
|
Masè M, Werner A, Putzer G, Avancini G, Falla M, Brugger H, Micarelli A, Strapazzon G. Low Ambient Temperature Exposition Impairs the Accuracy of a Non-invasive Heat-Flux Thermometer. Front Physiol 2022; 13:830059. [PMID: 35309078 PMCID: PMC8931521 DOI: 10.3389/fphys.2022.830059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 01/31/2022] [Indexed: 11/23/2022] Open
Abstract
Background Indirect core body temperature (CBT) monitoring from skin sensors is gaining attention for in-field applications thanks to non-invasivity, portability, and easy probe positioning. Among skin sensors, heat-flux devices, such as the so-called Double Sensor (DS), have demonstrated reliability under various experimental and clinical conditions. Still, their accuracy at low ambient temperatures is unknown. In this randomized cross-over trial, we tested the effects of cold temperature exposition on DS performance in tracking CBT. Methods Twenty-one participants were exposed to a warm (23.2 ± 0.4°C) and cold (−18.7 ± 1.0°C) room condition for 10 min, following a randomized cross-over design. The accuracy of the DS to estimate CBT in both settings was assessed by quantitative comparison with esophageal (reference) and tympanic (comparator) thermometers, using Bland–Altman and correlation analyses (Pearson’s correlation coefficient, r, and Lin’s concordance correlation coefficient, CCC). Results In the warm room setting, the DS showed a moderate agreement with the esophageal sensor [bias = 0.09 (−1.51; 1.69) °C, r = 0.40 (p = 0.069), CCC = 0.22 (−0.006; 0.43)] and tympanic sensor [bias = 2.74 (1.13; 4.35) °C, r = 0.54 (p < 0.05), CCC = 0.09 (0.008; 0.16)]. DS accuracy significantly deteriorated in the cold room setting, where DS temperature overestimated esophageal temperature [bias = 2.16 (−0.89; 5.22) °C, r = 0.02 (0.94), CCC = 0.002 (−0.05; 0.06)]. Previous exposition to the cold influenced temperature values measured by the DS in the warm room setting, where significant differences (p < 0.00001) in DS temperature were observed between randomization groups. Conclusion DS accuracy is influenced by environmental conditions and previous exposure to cold settings. These results suggest the present inadequacy of the DS device for in-field applications in low-temperature environments and advocate further technological advancements and proper sensor insulation to improve performance in these conditions.
Collapse
Affiliation(s)
- Michela Masè
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
| | - Andreas Werner
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany
- German Air Force – Centre of Aerospace Medicine, Aviation Physiology Training Centre, Aviation Physiology Diagnostic and Research, Königsbrück, Germany
| | - Gabriel Putzer
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Giovanni Avancini
- Department of Anaesthesia and Intensive Care, Santa Chiara Hospital, Trento, Italy
| | - Marika Falla
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Centre for Mind/Brain Sciences, CIMeC, University of Trento, Rovereto, Italy
| | - Hermann Brugger
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Alessandro Micarelli
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- ITER Center for Balance and Rehabilitation Research (ICBRR), Rome, Italy
| | - Giacomo Strapazzon
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
- *Correspondence: Giacomo Strapazzon,
| |
Collapse
|
9
|
Zafren K, Paal P. End-tidal CO2 <10 mm Hg is not a reason to terminate cardiopulmonary resuscitation in hypothermic cardiac arrest. Resuscitation 2022; 174:91-92. [DOI: 10.1016/j.resuscitation.2022.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Accepted: 03/08/2022] [Indexed: 11/15/2022]
|
10
|
Zhang Y, Liu G, Tang L. Research progress in core body temperature measurement during target temperature management. JOURNAL OF INTEGRATIVE NURSING 2022. [DOI: 10.4103/jin.jin_40_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|