1
|
Chen HC, Lee CY, Chang YL, Huang JY, Yang SF, Chang CK. Risk Factors for Corneal Endothelial Decompensation after Penetrating Keratoplasty: A Population-Based Cohort Study. J Clin Med 2024; 13:718. [PMID: 38337412 PMCID: PMC10856645 DOI: 10.3390/jcm13030718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/18/2024] [Accepted: 01/24/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: Endothelial decompensation is a common complication after penetrating keratopathy (PK), while the risk factors for endothelial decompensation after PK have not been fully elucidated. Consequently, we aim to investigate the possible risk factors for endothelial decompensation after PK. (2) Methods: This retrospective study was conducted using the National Health Insurance Research Database (NHIRD) of Taiwan. The main outcome was the development of endothelial decompensation after PK surgery. The effects of potential risk factors were compared between the patients with endothelial decompensation and the patients without endothelial decompensation via Cox proportional hazard regression, which produced the adjusted hazard ratio (aHR) and a 95% confidence interval (CI). (3) Results: Overall, 54 patients developed endothelial decompensation after PK surgery, with a ratio of 16.12 percent. The pre-existing type 2 diabetes mellitus (T2DM) (aHR: 1.924, 95% CI: 1.257-2.533, p = 0.0095) and history of cataract surgery (aHR: 1.687, 95% CI: 1.328-2.440, p = 0.0026) were correlated with the development of endothelial decompensation. In the subgroup analysis, the correlation between a history of cataract surgery and post-PK endothelial decompensation was more prominent in patients older than 60 years compared to their younger counterparts (p = 0.0038). (4) Conclusions: Pre-existing T2DM and a history of cataract surgery are associated with a higher incidence of post-PK endothelial decompensation.
Collapse
Affiliation(s)
- Hung-Chi Chen
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taoyuan 333, Taiwan;
- Department of Medicine, Chang Gung University College of Medicine, Taoyuan 333, Taiwan
- Center for Tissue Engineering, Chang Gung Memorial Hospital, Linkou, Taoyuan 333, Taiwan
| | - Chia-Yi Lee
- Institute of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
- Nobel Eye Institute, Taipei 115, Taiwan
- Department of Ophthalmology, Jen-Ai Hospital Dali Branch, Taichung 412, Taiwan
| | - Yu-Ling Chang
- Department of Medical Education, Cathay General Hospital, Taipei 106, Taiwan
| | - Jing-Yang Huang
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung 402, Taiwan
| | - Shun-Fa Yang
- Institute of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
- Department of Medical Research, Chung Shan Medical University Hospital, Taichung 402, Taiwan
| | - Chao-Kai Chang
- Nobel Eye Institute, Taipei 115, Taiwan
- Department of Optometry, Da-Yeh University, Chunghua 515, Taiwan
| |
Collapse
|
2
|
The predictability of graft thickness for Descemet's stripping automated endothelial keratoplasty using a mechanical microkeratome system. Sci Rep 2022; 12:22210. [PMID: 36564442 PMCID: PMC9789079 DOI: 10.1038/s41598-022-26679-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022] Open
Abstract
Descemet's stripping automated endothelial keratoplasty (DSAEK) is used for treating corneal endothelial dysfunction, and the postoperative visual acuity outcome depends on the thickness of the graft. We created a simple nomogram using factors affecting the cutting thickness during graft preparation via a mechanical microkeratome system for DSAEK. This retrospective study was conducted from May 2018 through October 2022 and included donor eyes cut by automatic methods. We measured the graft thickness, cutting accuracy, and assessed ten variables with donor/cornea-related factors potentially affecting the cutting thickness. Subsequently, we created a simple nomogram. We analyzed 81 donor tissues, and the donor median age was 76 years. The mean central graft thickness was 122.2 μm, with 62% of the grafts that could be cut within the target central graft thickness range. Comparatively, donor corneas from those with cardiac diseases were cut deeper (P = 0.007). The developed nomogram provided a 83% probability of estimating the post-cutting graft thickness within 25 µm. Our nomogram, which considers cause of death, enables reproducible production of graft of a desired thickness. A detailed analysis of donor tissues, including the cause of donor death and the characteristics from pressurization to cutting, will enable more precise DSAEK graft preparation.
Collapse
|