1
|
Lv S, Zhu G, Li Q, Zhang J, Tang L. Predicting in vivo therapeutic efficacy of CelTrac1000-labeled hair follicle epidermal neural crest stem cells in models of repairing rat facial nerve defects via second near-infrared fluorescence imaging. Life Sci 2024; 352:122869. [PMID: 38950644 DOI: 10.1016/j.lfs.2024.122869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/07/2024] [Accepted: 06/23/2024] [Indexed: 07/03/2024]
Abstract
AIMS To detect the therapeutic efficacy of CelTrac1000-labeled hair follicle epidermal neural crest stem cells (EPI-NCSCs) on repairing facial nerve defects by second near-infrared (NIR-II) fluorescence imaging. MATERIALS AND METHODS Firstly, CelTrac1000-labeled EPI-NCSCs were microinjected into the acellular nerve allografts (ANAs) to bridge a 10-mm-long gap in the buccal branch of facial nerve in adult rats. Then, Celtrac1000-labeled EPI-NCSCs were detected by NIR-II fluorescence imaging system to visualize the behavior of the transplanted cells in vivo. Additionally, the effect of the transplanted EPI-NCSCs on repairing facial nerve defect was examined. KEY FINDINGS Through 14 weeks of dynamic observation, the transplanted EPI-NCSCs survived in the ANAs in vivo after surgery. Meanwhile, the region of the NIR-II fluorescence signals was gradually limited to be consistent with the direction of the regenerative nerve segment. Furthermore, the results of functional and morphological analysis showed that the transplanted EPI-NCSCs could promote the recovery of facial paralysis and neural regeneration after injury. SIGNIFICANCE Our research provides a novel way to track the transplanted cells in preclinical studies of cell therapy for facial paralysis, and demonstrates the therapeutic potential of EPI-NCSCs combined with ANAs in bridging rat facial nerve defects.
Collapse
Affiliation(s)
- Shangrui Lv
- Department of Otorhinolaryngology-Head and Neck Surgery, Nanjing Medical University Affiliated Wuxi No 2 People's Hospital, Wuxi, 214002, Jiangsu, China
| | - Guochen Zhu
- Department of Otorhinolaryngology-Head and Neck Surgery, Nanjing Medical University Affiliated Wuxi No 2 People's Hospital, Wuxi, 214002, Jiangsu, China; Department of Otorhinolaryngology-Head and Neck Surgery, Jiangnan University Medical Center, Wuxi, 214002, Jiangsu, China; Department of Otorhinolaryngology-Head and Neck Surgery, Nantong University Affiliated Wuxi Clinical College, Wuxi, 214002, Jiangsu, China.
| | - Qianwen Li
- Department of Otorhinolaryngology-Head and Neck Surgery, Nanjing Medical University Affiliated Wuxi No 2 People's Hospital, Wuxi, 214002, Jiangsu, China
| | - Jing Zhang
- Department of Otorhinolaryngology-Head and Neck Surgery, Nantong University Affiliated Wuxi Clinical College, Wuxi, 214002, Jiangsu, China
| | - Li Tang
- Department of Otorhinolaryngology-Head and Neck Surgery, Nanjing Medical University Affiliated Wuxi No 2 People's Hospital, Wuxi, 214002, Jiangsu, China
| |
Collapse
|
3
|
Milek D, Echternacht SR, LaGuardia J, LaBarge D, Turpin L, Grobbelaar A, Leckenby JI. Evaluation of peripheral nerve regeneration in Murphy Roths Large mouse strain following transection injury. Regen Med 2023; 18:37-53. [PMID: 36255077 PMCID: PMC9892963 DOI: 10.2217/rme-2022-0098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/29/2022] [Indexed: 12/13/2022] Open
Abstract
Aim: Murphy Roths Large (MRL/MpJ) mice have demonstrated the ability to heal with minimal or no scar formation in several tissue types. In order to identify a novel animal model, this study sought to evaluate whether this attribute applies to peripheral nerve regeneration. Materials & methods: This was a two-phase study. 6-week-old male mice were divided into two interventional groups: nerve repair and nerve graft. The MRL/MpJ was compared with the C57BL/6J strain for evaluation of both functional and histological outcomes. Results: MRL/MpJ strain demonstrated superior axon myelination and less scar formation, however functional outcomes did not show significant difference between strains. Conclusion: Superior histological outcomes did not translate into superior peripheral nerve regeneration in MRL/MpJ strain.
Collapse
Affiliation(s)
- David Milek
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| | - Scott R Echternacht
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| | - Jonnby LaGuardia
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| | - Dalton LaBarge
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| | - Loel Turpin
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| | - Adriaan Grobbelaar
- Department of Plastic Surgery, Great Ormond Street Hospital for Children, 40 Bernard Street, London, WC1N 3JH, UK
- Department of Plastic Surgery, Inselspital University Hospital, 18 Freiburgstrasse, Bern, CH3008, Switzerland
| | - Jonathan I Leckenby
- Division of Plastic Surgery, Department of Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
| |
Collapse
|
4
|
Driscoll N, Erickson B, Murphy BB, Richardson AG, Robbins G, Apollo NV, Mentzelopoulos G, Mathis T, Hantanasirisakul K, Bagga P, Gullbrand SE, Sergison M, Reddy R, Wolf JA, Chen HI, Lucas TH, Dillingham T, Davis KA, Gogotsi Y, Medaglia JD, Vitale F. MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation. Sci Transl Med 2021; 13:eabf8629. [PMID: 34550728 PMCID: PMC8722432 DOI: 10.1126/scitranslmed.abf8629] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Soft bioelectronic interfaces for mapping and modulating excitable networks at high resolution and at large scale can enable paradigm-shifting diagnostics, monitoring, and treatment strategies. Yet, current technologies largely rely on materials and fabrication schemes that are expensive, do not scale, and critically limit the maximum attainable resolution and coverage. Solution processing is a cost-effective manufacturing alternative, but biocompatible conductive inks matching the performance of conventional metals are lacking. Here, we introduce MXtrodes, a class of soft, high-resolution, large-scale bioelectronic interfaces enabled by Ti3C2 MXene (a two-dimensional transition metal carbide nanomaterial) and scalable solution processing. We show that the electrochemical properties of MXtrodes exceed those of conventional materials and do not require conductive gels when used in epidermal electronics. Furthermore, we validate MXtrodes in applications ranging from mapping large-scale neuromuscular networks in humans to cortical neural recording and microstimulation in swine and rodent models. Last, we demonstrate that MXtrodes are compatible with standard clinical neuroimaging modalities.
Collapse
Affiliation(s)
- Nicolette Driscoll
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
| | - Brian Erickson
- Department of Psychology, Drexel University, Philadelphia, PA 19104, USA
| | - Brendan B. Murphy
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
| | - Andrew G. Richardson
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Gregory Robbins
- Department of Physical Medicine and Rehabilitation, University of Pennsylvania, PA 19104, USA
| | - Nicholas V. Apollo
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
| | - Georgios Mentzelopoulos
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
| | - Tyler Mathis
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA
- A.J. Drexel Nanomaterials Institute, Drexel University, Philadelphia, PA 19104, USA
| | - Kanit Hantanasirisakul
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA
- A.J. Drexel Nanomaterials Institute, Drexel University, Philadelphia, PA 19104, USA
| | - Puneet Bagga
- Department of Radiology, Center for Magnetic Resonance and Optical Imaging, University of Pennsylvania, Philadelphia, PA 19104, USA
- Diagnostic Imaging, St Jude Children’s Research Hospital, Memphis, TN 38105, USA
| | - Sarah E. Gullbrand
- Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA 19104, USA
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Matthew Sergison
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Ravinder Reddy
- Department of Radiology, Center for Magnetic Resonance and Optical Imaging, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - John A. Wolf
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - H. Isaac Chen
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Timothy H. Lucas
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Timothy Dillingham
- Department of Physical Medicine and Rehabilitation, University of Pennsylvania, PA 19104, USA
| | - Kathryn A. Davis
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Yury Gogotsi
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA
- A.J. Drexel Nanomaterials Institute, Drexel University, Philadelphia, PA 19104, USA
| | - John D. Medaglia
- Department of Psychology, Drexel University, Philadelphia, PA 19104, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Neurology, Drexel University, Philadelphia, PA 19104, USA
| | - Flavia Vitale
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA 19104, USA
- Department of Physical Medicine and Rehabilitation, University of Pennsylvania, PA 19104, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
8
|
Zheng XS, Griffith AY, Chang E, Looker MJ, Fisher LE, Clapsaddle B, Cui XT. Evaluation of a conducting elastomeric composite material for intramuscular electrode application. Acta Biomater 2020; 103:81-91. [PMID: 31863910 DOI: 10.1016/j.actbio.2019.12.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 11/25/2019] [Accepted: 12/10/2019] [Indexed: 01/14/2023]
Abstract
Electrical stimulation of the muscle has been proven efficacious in preventing atrophy and/or reanimating paralyzed muscles. Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes (CNT) with fluorosilicone insulation. The electrode wire has a Young's modulus of 804 (±99) kPa, which better mimics the muscle tissue modulus than conventional stainless steel (SS) electrodes. Additionally, the non-metallic composition enables metal-artifact free CT and MR imaging. These soft wire (SW) electrodes present comparable electrical impedance to SS electrodes of similar geometric surface area, activate muscle at a lower threshold, and maintain stable electrical properties in vivo up to 4 weeks. Histologically, the SW electrodes elicited significantly less fibrotic encapsulation and less IBA-1 positive macrophage accumulation than the SS electrodes at one and three months. Further phenotyping the macrophages with the iNOS (pro-inflammatory) and ARG-1 (pro-healing) markers revealed significantly less presence of pro-inflammatory macrophage around SW implants at one month. By three months, there was a significant increase in pro-healing macrophages (ARG-1) around the SW implants but not around the SS implants. Furthermore, a larger number of AchR clusters closer to SW implants were found at both time points compared to SS implants. These results suggest that a softer implant encourages a more intimate and healthier electrode-tissue interface. STATEMENT OF SIGNIFICANCE: Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes with fluorosilicone insulation. This elastomeric composite results in an electrode wire with a Young's modulus mimicking that of the muscle tissue, which elicits significantly less foreign body response compared to stainless steel wires. The lack of metal in this composite also enables metal-artifact free MRI and CT imaging.
Collapse
Affiliation(s)
- X Sally Zheng
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
| | - Azante Y Griffith
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
| | - Emily Chang
- TDA Research Inc., Wheat Ridge, CO 80033, United States
| | | | - Lee E Fisher
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
| | | | - X Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States.
| |
Collapse
|