1
|
Fukuchi K, Shibutani T, Terakawa Y, Nouno Y, Tateishi E, Onoguchi M, Tetsuya F. Image Quality of Cardiac Silicon Photomultiplier PET/CT Using an Infant Phantom of Extremely Low Birth Weight. J Nucl Med Technol 2024; 52:247-251. [PMID: 38901966 DOI: 10.2967/jnmt.124.267826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Accepted: 05/16/2024] [Indexed: 06/22/2024] Open
Abstract
The lack of pediatrics-specific equipment for nuclear medicine imaging has resulted in insufficient diagnostic information for newborns, especially low-birth-weight infants. Although PET offers high spatial resolution and low radiation exposure, its use in newborns is limited. This study investigated the feasibility of cardiac PET imaging using the latest silicon photomultiplier (SiPM) PET technology in infants of extremely low birth weight (ELBW) using a phantom model. Methods: The study used a phantom model representing a 500-g ELBW infant with brain, cardiac, liver, and lung tissues. The cardiac tissue included a 3-mm-thick defect mimicking myocardial infarction. Organ tracer concentrations were calculated assuming 18F-FDG myocardial viability scans and 18F-flurpiridaz myocardial perfusion scans and were added to the phantom organs. Imaging was performed using an SiPM PET/CT scanner with a 5-min acquisition. The data acquired in list mode were reconstructed using 3-dimensional ordered-subsets expectation maximization with varying iterations. Image evaluation was based on the depiction of the myocardial defect compared with normal myocardial accumulation. Results: Increasing the number of iterations improved the contrast of the myocardial defect for both tracers, with 18F-flurpiridaz showing higher contrast than 18F-FDG. However, even at 50 iterations, both tracers overestimated the defect accumulation. A bull's-eye image can display the flow metabolism mismatch using images from both tracers. Conclusion: SiPM PET enabled cardiac PET imaging in a 500-g ELBW phantom with a 1-g heart. However, there were limitations in adequately depicting these defects. Considering the image quality and defect contrast,18F-flurpiridaz appears more desirable than 18F-FDG if only one of the two can be used.
Collapse
Affiliation(s)
- Kazuki Fukuchi
- Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Osaka, Japan;
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical, and Health Sciences, Kanazawa University, Kanazawa, Japan; and
| | - Yusuke Terakawa
- Department of Radiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Yoshifumi Nouno
- Department of Radiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Emi Tateishi
- Department of Radiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical, and Health Sciences, Kanazawa University, Kanazawa, Japan; and
| | - Fukuda Tetsuya
- Department of Radiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| |
Collapse
|
2
|
Barak-Corren Y, Herz C, Lasso A, Dori Y, Tang J, Smith CL, Callahan R, Rome JJ, Gillespie MJ, Jolley MA, O’Byrne ML. Calculating Relative Lung Perfusion Using Fluoroscopic Sequences and Image Analysis: The Fluoroscopic Flow Calculator. Circ Cardiovasc Interv 2024; 17:e013204. [PMID: 38152881 PMCID: PMC10872906 DOI: 10.1161/circinterventions.123.013204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 10/03/2023] [Indexed: 12/29/2023]
Abstract
BACKGROUND Maldistribution of pulmonary blood flow in patients with congenital heart disease impacts exertional performance and pulmonary artery growth. Currently, measurement of relative pulmonary perfusion can only be performed outside the catheterization laboratory. We sought to develop a tool for measuring relative lung perfusion using readily available fluoroscopy sequences. METHODS A retrospective cohort study was conducted on patients with conotruncal anomalies who underwent lung perfusion scans and subsequent cardiac catheterizations between 2011 and 2022. Inclusion criteria were nonselective angiogram of pulmonary vasculature, oblique angulation ≤20°, and an adequate view of both lung fields. A method was developed and implemented in 3D Slicer's SlicerHeart extension to calculate the amount of contrast that entered each lung field from the start of contrast injection and until the onset of levophase. The predicted perfusion distribution was compared with the measured distribution of pulmonary blood flow and evaluated for correlation, accuracy, and bias. RESULTS In total, 32% (79/249) of screened studies met the inclusion criteria. A strong correlation between the predicted flow split and the measured flow split was found (R2=0.83; P<0.001). The median absolute error was 6%, and 72% of predictions were within 10% of the true value. Bias was not systematically worse at either extreme of the flow distribution. The prediction was found to be more accurate for either smaller and younger patients (age 0-2 years), for right ventricle injections, or when less cranial angulations were used (≤20°). In these cases (n=40), the prediction achieved R2=0.87, median absolute error of 5.5%, and 78% of predictions were within 10% of the true flow. CONCLUSIONS The current study demonstrates the feasibility of a novel method for measuring relative lung perfusion using conventional angiograms. Real-time measurement of lung perfusion at the catheterization laboratory has the potential to reduce unnecessary testing, associated costs, and radiation exposure. Further optimization and validation is warranted.
Collapse
Affiliation(s)
- Yuval Barak-Corren
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Christian Herz
- Division of Pediatric Cardiac Anesthesia, The Children’s Hospital of Philadelphia and Department of Anesthesia and Critical Care, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Andras Lasso
- Laboratory for Percutaneous Surgery, Queen’s University, Kingston, ON
| | | | - Jessica Tang
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Christopher L Smith
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Ryan Callahan
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Jonathan J Rome
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Matthew J Gillespie
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Matthew A Jolley
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
- Division of Pediatric Cardiac Anesthesia, The Children’s Hospital of Philadelphia and Department of Anesthesia and Critical Care, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Michael L O’Byrne
- Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
- Clinical Futures, The Children’s Hospital of Philadelphia, Pennsylvania, Philadelphia, PA
- Leonard Davis Institute and Center for Cardiovascular Outcomes, Quality, and Evaluative Research, Perelman School of Medicine at the University of Pennsylvania, Philadelphia PA
| |
Collapse
|
3
|
Perrone MA, Cimini A, Ricci M, Pizzoferro M, Garganese MC, Raponi M, Schillaci O. Myocardial Functional Imaging in Pediatric Nuclear Cardiology. J Cardiovasc Dev Dis 2023; 10:361. [PMID: 37754790 PMCID: PMC10531976 DOI: 10.3390/jcdd10090361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 08/03/2023] [Accepted: 08/22/2023] [Indexed: 09/28/2023] Open
Abstract
The role of nuclear medicine in pediatric cardiology has grown rapidly over the years, providing useful functional and prognostic information and playing a complementary role to morphological imaging in the evaluation of myocardial perfusion, cardiovascular inflammation and infections, and cardiac sympathetic innervation. The aim of this narrative review is to summarize and highlight the most important evidence on pediatric nuclear cardiology, describing clinical applications and the possibilities, advantages, and limitations of nuclear medicine techniques. Moreover, a special focus will be given to the minimization of radiation exposure in pediatric nuclear cardiology imaging, a critical topic in children.
Collapse
Affiliation(s)
- Marco Alfonso Perrone
- Department of Pediatric Cardiology and Cardiac Surgery, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
- Division of Cardiology and CardioLab, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Andrea Cimini
- Nuclear Medicine Unit, St. Salvatore Hospital, 67100 L’Aquila, Italy
| | - Maria Ricci
- Nuclear Medicine Unit, Cardarelli Hospital, 86100 Campobasso, Italy
| | - Milena Pizzoferro
- Division of Nuclear Medicine, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
| | | | - Massimiliano Raponi
- Health Directorate, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
| | - Orazio Schillaci
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy
| |
Collapse
|