1
|
Toma M, Oprea V, Scarlat F, Bucuri CE, Andercou O, Mihaileanu F, Grad O, Rosianu M, Molnar C. Quality of life and abdominal wall functionality after abdominal wall reconstruction: A prospective single center follow-up study. Hernia 2024; 28:2223-2234. [PMID: 39240469 PMCID: PMC11530502 DOI: 10.1007/s10029-024-03143-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 08/13/2024] [Indexed: 09/07/2024]
Abstract
BACKGROUND Fascial breakdown with the occurrence of an incisional hernia (IH) is an important and challenging complication of any laparotomy. For a long time, the success of the abdominal wall reconstruction (AWR) was measured only from the surgeon's perspective by defining outcome measures such as wound morbidity and recurrence. The understanding that complete recovery is difficult to assess without considering patients has shifted the paradigm of optimal outcomes to Patient Reported Outcome Measures (PROMS) and Quality of Life (QoL), which are pivotal to evaluate the success and efficacy of AWR. METHODS We conducted a prospective follow-up study of 91 patients undergoing mesh-augmented abdominal wall reconstruction for primary or recurrent incisional hernia between January 2021 and December 2023. Demographic data, comorbidities, and hernia characteristics were recorded. All patients were evaluated preoperatively by a native abdomino-pelvic CT scan to assess the characteristics of hernia (length, width, surface, and volume of the incisional hernia sac and of peritoneal cavity), the presence of mesh (if previously inserted), and abdominal wall muscles status. All intervention were performed by the same surgical team according to the techniques described by Rives - Stoppa (RS), Ramirez (ACS), and Novitsky (PCS). Abdominal wall function was assessed using trunk raising (TR) and double leg lowering (DLL) measurements performed preoperatively, 1 month, 6 months, and 1 year postoperatively. At the same time, pre- and post-operative quality of life was analysed using the EQ-5D score. RESULTS Mean age of 59.42 ± 12.28 years and a male/female ratio of 35/56 were recorded, most of them being obese. There were 36 (42%) patients with defects larger than 10 cm. The distribution of the type of surgical intervention was: RS 35 patients, ACS 13 patients, and PCS 43 patients. The mean value of combined score for the preoperative abdominal wall functionality was 4.41 ± 1.67 (2-8) while the mean value of preoperative EQ-5D index was 0.652 ± 0.026 (-0.32-1.00). QoL was poor and very poor for 48% (44) of the patients who recorded index values less than 0.56 (50% percentile). Preoperative EQ-5D index was highly correlated with Combined AWF score (r = 0.620; p < 0.0001) and the correlation was specific (AUC = 0.799; p < 0.0001; asymptotic 95%CI = 0.711-0.923). At 12 months, the AWF score increased to 8.13 ± 2.58 (1-10) and the QoL total score to 0.979 ± 0.007 (0.71-1). Good and very good total scores for QoL were recorded for 47 patients (84%) compared to 33 (36%) in the preoperative evaluation (χ2 with Yates continuity correction for two degrees of liberty = 46.04; p < 0.00001). CONCLUSION Our results suggest that patients can expect to see a significant overall improvement in all five components of QoL measured with the help of Eq. 5D questionnaire. This improvement is dependent by hernia size, and some individual patient's factors (diabetes, cardiovascular diseases, and age over 60 years).
Collapse
Affiliation(s)
- M Toma
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, Cluj-Napoca, 22G-ral Traian Mosoiu, Cluj-Napoca, Romania
- Pharmacy, Science and Technology, "George Emil Palade" University of Medicine, Targu-Mures, Romania
| | - V Oprea
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, Cluj-Napoca, 22G-ral Traian Mosoiu, Cluj-Napoca, Romania.
- "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.
| | - Florentina Scarlat
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, Cluj-Napoca, 22G-ral Traian Mosoiu, Cluj-Napoca, Romania
| | - Carmen Elena Bucuri
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, Cluj-Napoca, 22G-ral Traian Mosoiu, Cluj-Napoca, Romania
- "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - O Andercou
- "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
- Second Clinical Department of Surgery, Emergency Clinical County Hospital, Cluj- Napoca, Romania
| | - F Mihaileanu
- "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
- Second Clinical Department of Surgery, Emergency Clinical County Hospital, Cluj- Napoca, Romania
| | - O Grad
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, Cluj-Napoca, 22G-ral Traian Mosoiu, Cluj-Napoca, Romania
- "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - M Rosianu
- Clinical Department of Radiology - Medical Imaging, Emergency Clinical County Hospital, Sibiu, Romania
| | - C Molnar
- Pharmacy, Science and Technology, "George Emil Palade" University of Medicine, Targu-Mures, Romania
- First Clinical Department of Surgery, Emergency Clinical County Hospital, Targu- Mures, Romania
| |
Collapse
|
2
|
Klein A, Willms A, Güsgen C, Schwab R, Schaaf S. [Planned Ventral Hernia After Open Abdomen Therapy: Complex Incisional Hernia Repair]. Zentralbl Chir 2024; 149:516-521. [PMID: 39577460 DOI: 10.1055/a-2420-1303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2024]
Abstract
A planned ventral hernia after open abdomen therapy is a rare hernia entity because the fascial closure rate has been increased due to established concepts for open abdominal treatment. Nevertheless, fascial closure is not always successful, and a planned ventral hernia has to be treated later. Preoperative optimisation and planning are essential for such challenging abdominal wall repairs.In a single centre retrospective analysis, all incisional hernias from 2013 to 2023 (n = 632) were identified and planned hernias after a laparostomy were selected (n = 11). The data on surgical management were obtained from the patient files for the operation reports. Literature search was conducted with PubMed (Medline).In all cases a physical examination, abdominal sonography, CT abdomen and a colonoscopy were carried out preoperatively. The median size of the abdominal wall defects were horizontally 13 cm (6-35 cm) and vertically 18 cm (10-28 cm). Botulinum toxin A has been used preoperatively since 2018. Median fascial closure was successful intraoperatively in all 11 patients. The surgical techniques included sublay, IPOM, sandwich technique, intraoperative fascial traction, and component separation.Planned ventral hernias after open abdomen treatment should always be considered complex hernias for which the entire expertise in hernia surgery is required. Comprehensive preoperative optimisation with botulinum toxin A infiltration is essential to facilitate anatomically appropriate reconstruction through midline closure with mesh augmentation.
Collapse
Affiliation(s)
- Angelina Klein
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Bundeswehrzentralkrankenhaus, Koblenz, Deutschland
| | - Arnulf Willms
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Bundeswehrzentralkrankenhaus, Koblenz, Deutschland
- Arnulf Willms, Bad Breisig, Deutschland
| | - Christoph Güsgen
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Bundeswehrzentralkrankenhaus, Koblenz, Deutschland
| | - Robert Schwab
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Bundeswehrzentralkrankenhaus, Koblenz, Deutschland
| | - Sebastian Schaaf
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Bundeswehrzentralkrankenhaus, Koblenz, Deutschland
| |
Collapse
|
3
|
Dias Rasador AC, Marcolin P, da Silveira CAB, Kasakewitch JPG, Nogueira R, de Figueiredo SMP, Lima DL, Malcher F. The impact of simultaneous panniculectomy in ventral hernia repair: a systematic review and meta-analysis. Hernia 2024; 28:2125-2136. [PMID: 39240467 DOI: 10.1007/s10029-024-03149-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Accepted: 08/15/2024] [Indexed: 09/07/2024]
Abstract
BACKGROUND Ventral hernia repair (VHR) is often performed in patients with obesity. While panniculectomy improves cosmetic outcomes, it may increase complications, particularly wound-related adverse events. Despite its widespread use, the impact of concurrent panniculectomy on postoperative complications in VHR remains unclear. This study aimed to assess whether concurrent panniculectomy increases postoperative complications in VHR. METHODS We searched PubMed, Scopus, Web of Science, and Cochrane databases for studies published up to April 2024 comparing surgical outcomes in patients undergoing VHR with and without concurrent panniculectomy. We assessed recurrence, seroma, hematoma, surgical site infections (SSI), wound dehiscence, skin necrosis, chronic wound, length of stay (LOS), readmissions, duration of surgery, and deep venous thromboembolism (DVT). Risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were pooled for dichotomous and continuous endpoints, respectively. We used RStudio for statistics and heterogeneity was assessed with I2 statistics. RESULTS We screened 890 studies, fully reviewed 40, and included 11 observational studies and 2 randomized controlled trials, comprising 23,354 patients. Of these, 2,972 (13%) patients underwent VHR with concurrent panniculectomy (VHR-PAN). The mean age ranged from 37 to 59 years, and 73% of the sample were women. The mean BMI varied from 29 to 45 kg/m2, and 75% of the patients underwent mesh repair. The mean defect area ranged from 36 to 389 cm2. Most repairs were performed using mesh (75%) in an underlay position (68%) and 24% underwent component separation. VHR-PAN was associated with a decrease in recurrence rates (RR 0.74; 95% CI 0.62 to 0.89; p < 0.001; I2 = 1%) with a follow-up ranging from 1 to 36 months. Furthermore, subgroup analysis of recurrence in studies with a mean follow-up of at least one year also showed a reduction in recurrence (RR 0.72; 95% CI 0.60 to 0.88; p < 0.001; I2 = 12%), with a follow-up ranging from 12 to 36 months. Moreover, concurrent panniculectomy was associated with increased SSI (RR 1.31; 95% CI 1.13 to 1.51; p < 0.001; I2 = 0%), SSO (RR 1.49; 95% CI 1.26 to 1.77; p < 0.001; I2 = 11%), skin necrosis (RR 2.94; 95% CI 1.26 to 6.85; p = 0.012; I2 = 0%) and reoperation (RR 1.73; 95% CI 1.32 to 2.28; p < 0.001; I2 = 0%), and longer LOS (MD 0.90 day; 95%CI 0.40 to 1.40; p < 0.001; I2 = 56%). There was no significant difference in ocurrence of DVT, enterocutaneous fistula, hematoma, seroma, or wound dehiscence, neither on operative time or readmission rates. CONCLUSION VHR-PAN is associated with lower recurrence rates. However, it increases the risk of wound morbidity and reoperation and prolongs hospital stay. Surgeons should carefully weigh the risks and benefits of performing VHR-PAN. STUDY REGISTRATION A review protocol for this systematic review and meta-analysis was registered at PROSPERO (CRD42024542721).
Collapse
Affiliation(s)
- Ana Caroline Dias Rasador
- Bahiana School of Medicine and Public Health, Dom João VI Avenue, 275, Salvador, BA, 40290-000, Brazil
| | - Patricia Marcolin
- Department of Surgery, Federal University of the Southern Border, Passo Fundo, RS, Brazil
| | | | | | - Raquel Nogueira
- Department of Surgery, Montefiore Medical Center, 1825 Eastchester Rd, Bronx, New York, NY, 1046, USA
| | | | - Diego Laurentino Lima
- Department of Surgery, Montefiore Medical Center, 1825 Eastchester Rd, Bronx, New York, NY, 1046, USA.
| | - Flavio Malcher
- Division of General Surgery, NYU Langone Health, New York, NY, 10016, USA
| |
Collapse
|
4
|
Lesch C, Nessel R, Adolf D, Hukauf M, Köckerling F, Kallinowski F, Willms A, Schwab R, Zarras K. STRONGHOLD first-year results of biomechanically calculated abdominal wall repair: a propensity score matching. Hernia 2024; 28:63-73. [PMID: 37815731 PMCID: PMC10891228 DOI: 10.1007/s10029-023-02897-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/18/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE Every year around 70,000 people in Germany suffer from an abdominal incisional hernia that requires surgical treatment. Five years after reconstruction about 25% reoccur. Incisional hernias are usually closed with mesh using various reconstruction techniques, summarized here as standard reconstruction (SR). To improve hernia repair, we established a concept for biomechanically calculated reconstructions (BCR). In the BCR, two formulas enable customized patient care through standardized biomechanical measures. This study aims to compare the clinical outcomes of SR and BCR of incisional hernias after 1 year of follow-up based on the Herniamed registry. METHODS SR includes open retromuscular mesh augmented incisional hernia repair according to clinical guidelines. BCR determines the required strength (Critical Resistance to Impacts related to Pressure = CRIP) preoperatively depending on the hernia size. It supports the surgeon in reliably determining the Gained Resistance, based on the mesh-defect-area-ratio, further mesh and suture factors, and the tissue stability. To compare SR and BCR repair outcomes in incisional hernias at 1 year, propensity score matching was performed on 15 variables. Included were 301 patients with BCR surgery and 23,220 with standard repair. RESULTS BCR surgeries show a significant reduction in recurrences (1.7% vs. 5.2%, p = 0.0041), pain requiring treatment (4.1% vs. 12.0%, p = 0.001), and pain at rest (6.9% vs. 12.7%, p = 0.033) when comparing matched pairs. Complication rates, complication-related reoperations, and stress-related pain showed no systematic difference. CONCLUSION Biomechanically calculated repairs improve patient care. BCR shows a significant reduction in recurrence rates, pain at rest, and pain requiring treatment at 1-year follow-up compared to SR.
Collapse
Affiliation(s)
- C Lesch
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
| | - R Nessel
- General, Visceral and Pediatric Surgery, Klinikum Am Gesundbrunnen, Am Gesundbrunnen 20‑26, 74078, Heilbronn, Germany
| | - D Adolf
- StatConsult, Am Fuchsberg 11, 39112, Magdeburg, Germany
| | - M Hukauf
- StatConsult, Am Fuchsberg 11, 39112, Magdeburg, Germany
| | - F Köckerling
- Vivantes Humboldt Hospital Berlin, Center for Hernia Surgery, Academic Teaching Hospital of Charité University Medicine, Am Nordgraben 2, 13509, Berlin, Germany
| | - F Kallinowski
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany
| | - A Willms
- General and Visceral Surgery, Bundeswehrkrankenhaus Hamburg, Lesserstrasse 180, 22049, Hamburg, Germany
| | - R Schwab
- General, Visceral and Thorax Surgery, BundeswehrZentralkrankenhaus Koblenz, Rübenacher Strasse 170, 56072, Koblenz, Germany
| | - K Zarras
- Visceral, Minimal Invasive and Oncological Surgery, Marien Hospital Düsseldorf, Schloßstraße 85, 40477, Düsseldorf, Germany
| |
Collapse
|
5
|
Louis V, Alhammadi F, Sauvinet G, Charleux-Muller D, Rohr S, Brigand C, Romain B, Delhorme JB. How I do it: using a hammock mesh in the reconstruction of inguinal ligament during a wide en-bloc resection of a groin mesenchymal tumor. Hernia 2024; 28:261-267. [PMID: 37368184 DOI: 10.1007/s10029-023-02829-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Accepted: 06/18/2023] [Indexed: 06/28/2023]
Abstract
PURPOSE In case of soft tissue sarcomas (STS), an en-bloc resection with safe margins is recommended. To ensure safe removal without tumor rupture, STS of the groin area, retroperitoneal or pelvic mesenchymal tumors may require incision or resection of the inguinal ligament. Solid reconstruction is mandatory to prevent early and late postoperative femoral hernias. We present here a new technique of inguinal ligament reconstruction. METHODS Between September 2020 and September 2022, patients undergoing incision and/or resection of inguinal ligaments during a wide en-bloc resection of STS of the groin area in the Department of General Surgery in Strasbourg were included. All patients had an inguinal ligament reconstruction with biosynthetic slowly resorbable mesh shaped as a hammock, pre- or intraperitoneally, associated or not with loco-regional pedicled muscular flaps. RESULTS A total of 7 hammock mesh reconstructions were performed. One or several flaps were necessary in 57% of cases (4 patients): either for inguinal ligament reconstruction only (n = 1), for recovering of femoral vessels (n = 1), and for both ligament reconstruction and defect covering (n = 2). The major morbidity rate was 14.3% (n = 1), related to a thigh surgical site infection due to sartorius flap infarction. After a median follow-up of 17.8 months (range 7-31), there was neither early nor late occurrence of post-operative femoral hernia. CONCLUSIONS This is a new surgical tool for inguinal ligament reconstruction with the implementation of a biosynthetic slowly resorbable mesh shaped as a hammock, which should be compared to other techniques.
Collapse
Affiliation(s)
- V Louis
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France.
| | - F Alhammadi
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
| | - G Sauvinet
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
| | - D Charleux-Muller
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
| | - S Rohr
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
- INSERM UMR_S1113, Université de Strasbourg, FMTS, 3 Avenue Molière, 67200, Strasbourg, France
| | - C Brigand
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
- INSERM UMR_S1113, Université de Strasbourg, FMTS, 3 Avenue Molière, 67200, Strasbourg, France
| | - B Romain
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
- INSERM UMR_S1113, Université de Strasbourg, FMTS, 3 Avenue Molière, 67200, Strasbourg, France
| | - J-B Delhorme
- Department of General and Digestive Surgery, Hautepierre Hospital, Strasbourg University Hospital, Avenue Molière, 67200, Strasbourg, France
- INSERM UMR_S1113, Université de Strasbourg, FMTS, 3 Avenue Molière, 67200, Strasbourg, France
| |
Collapse
|
6
|
Hiekkaranta JM, Ahonen M, Mäkäräinen E, Saarnio J, Pinta T, Vironen J, Niemeläinen S, Vento P, Nikki M, Ohtonen P, Rautio T. Laparoscopic versus hybrid approach for treatment of incisional ventral hernia: a 5-10-year follow-up of the randomized controlled multicenter study. Hernia 2024; 28:191-197. [PMID: 37594636 PMCID: PMC10890975 DOI: 10.1007/s10029-023-02849-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/23/2023] [Indexed: 08/19/2023]
Abstract
PURPOSE In this long-term follow-up of a prospective, randomized, and multicenter study, we compare the results of a group receiving laparoscopic incisional ventral hernia repair using intraperitoneal onlay mesh (LG) to a group receiving a hybrid hernia repair where open closure of fascial defect was added to intraperitoneal mesh placement (HG). METHODS Originally, 193 patients with 2-7 cm incisional hernias were randomly assigned to either the LG or HG during the 30-month recruitment period in 2012 to 2015. Long-term follow-up was conducted 5-10 years after surgery to evaluate hernia recurrence rate and quality of life (QoL). RESULTS In all, 65 patients in the LG and 60 in the HG completed the long-term follow-up with a median follow-up period of 87 months. Recurrent hernia was detected in 11 of 65 patients (16.9%) in the LG and 10 of 60 patients (16.7%) in the HG (p > 0.9). Kaplan-Meier analysis demonstrated a recurrence rate approaching 20% in both groups, with similar curves. Three patients in the LG (4.6% and five patients in the HG (8.1%) had undergone re-operation due to recurrence (p = 0.48). There was no difference in patient-reported QoL measured using the SF-36 questionnaire. Mean pain scores were similar between groups, mean numeric rating scale (NRS) 0 to 10 being 1.1 in the LG and 0.7 in the HG (p = 0.43). CONCLUSION Fascial closure did not reduce hernia recurrence rate in this study population, even though it has been shown to be beneficial and recommended in surgery guidelines. In the long term, recurrence rate for both groups is similar.
Collapse
Affiliation(s)
- J M Hiekkaranta
- Department of Surgery, Oulu University Hospital, Oulu, Finland.
| | - M Ahonen
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - E Mäkäräinen
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - J Saarnio
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - T Pinta
- Department of Surgery, Seinäjoki Central Hospital, Seinäjoki, Finland
| | - J Vironen
- Department of Surgery, Helsinki University Hospital, Helsinki, Finland
| | - S Niemeläinen
- Department of Surgery, Tampere University Hospital, Tampere, Finland
| | - P Vento
- Department of Surgery, Kymenlaakso Central Hospital, Kotka, Finland
| | - M Nikki
- Department of Radiology, Oulu University Hospital, Oulu, Finland
| | - P Ohtonen
- Research Service Unit, The Research Unit of Surgery, Anesthesia and Intensive Care, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - T Rautio
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| |
Collapse
|
7
|
Zamkowski M, Tomaszewska A, Lubowiecka I, Śmietański M. Biomechanical causes for failure of the Physiomesh/Securestrap system. Sci Rep 2023; 13:17504. [PMID: 37845369 PMCID: PMC10579252 DOI: 10.1038/s41598-023-44940-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Accepted: 10/13/2023] [Indexed: 10/18/2023] Open
Abstract
This study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh in various directions and the strength of the mesh-tissue-staple junction. Ex-vivo experiments on porcine abdominal wall models were performed to observe the system's behavior under simulated intra-abdominal pressure load. Numerical simulations using finite element analysis were employed to support the experimental findings. The results reveal nonlinearity, anisotropy, and non-homogeneity in the mechanical properties of the Physiomesh, with stress concentration observed in the polydioxanone (PDO) stripe. The mesh-tissue junction exhibited inadequate fixation strength, leading to staple pull-out or breakage. The ex-vivo models demonstrated failure under higher pressure loads. Numerical simulations supported these findings, revealing the reaction forces exceeding the experimentally determined strength of the mesh-tissue-staple junction. The implications of this study extend beyond the specific case of the Physiomesh/Securestrap system, providing insights into the mechanics of implant-tissue systems. By considering biomechanical factors, researchers and clinicians can make informed decisions to develop improved implants that mimic the mechanics of a healthy abdominal wall. This knowledge can contribute to better surgical outcomes and reduce complications in abdominal hernia repair and to avoid similar failures in future.
Collapse
Affiliation(s)
- Mateusz Zamkowski
- Department of General Surgery and Hernia Center, Swissmed Hospital, Wileńska 44, 80-215, Gdańsk, Poland.
| | - Agnieszka Tomaszewska
- Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Izabela Lubowiecka
- Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Maciej Śmietański
- Department of General Surgery and Hernia Center, Swissmed Hospital, Wileńska 44, 80-215, Gdańsk, Poland
- II Department of Radiology, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
8
|
Thölix AM, Kössi J, Harju J. One-year outcome after open inguinal hernia repair with self-fixated mesh: a randomized controlled trial. Langenbecks Arch Surg 2023; 408:369. [PMID: 37733083 PMCID: PMC10514172 DOI: 10.1007/s00423-023-03106-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 09/09/2023] [Indexed: 09/22/2023]
Abstract
PURPOSE The aim of this study was to analyze pain after surgery with the use of self-fixated meshes, which are commonly used as an alternative for sutured mesh in open inguinal hernia repair. METHODS This prospective randomized clinical trial was conducted from November 2018 to March 2021, with a follow-up duration of 12 months. Male patients, aged 18-85, and suitable for day case surgery, were included. The patients received the self-adhesive Adhesix™ mesh or the self-gripping Progrip™ mesh in open inguinal hernia surgery. The primary outcome was the number of additional follow-up visits due to post-operative pain. Secondary outcomes included intensity of pain, quality of life measures, and complications. RESULTS Two hundred seventy patients were included in this trial, 132 with Adhesix™ (A group), and 138 with Progrip™ (P-group). All patients' medical records were reviewed 12 months after surgery, and 207 patients (76.2%) completed 12-month follow-up. The number of patients needing additional follow-up visits 3-12 months after surgery were comparable (A group 3/3.0%, P-group 6/5.6%). The numeric rating scale was low at 12 months after surgery (at rest A 0.21, P 0.34, at exercise A 0.78, P 0.90). The incidence of chronic pain, that is moderate or severe pain during exercise, was 5 patients (5.2%) with Adhesix™ and 8 patients (7.4%) with Progrip™ (P = 0.333). Two hernia recurrences (1.0%) were established, one in each group. CONCLUSION At 1 year after hernia surgery, the use of self-gripping and self-adhesive meshes lead to successful pain reduction and quality of life improvement. TRIAL REGISTRATION CLINICALTRIALS com NCT03734224.
Collapse
Affiliation(s)
- Anna-Maria Thölix
- Department of Abdominal Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
| | - Jyrki Kössi
- Department of Surgery, Päijät-Häme Central Hospital, Lahti, Finland
| | - Jukka Harju
- Department of Abdominal Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| |
Collapse
|
9
|
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study. Surg Endosc 2023; 37:1781-1788. [PMID: 36229552 DOI: 10.1007/s00464-022-09699-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/29/2022] [Indexed: 10/17/2022]
Abstract
BACKGROUND Although international guidelines recommend not fixing the mesh in almost all cases of laparoendoscopic repairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of high-quality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. METHOD The authors conducted an experiment with scientists from Universities of Technology in a model that reflects the conditions in the groin area. By simulating conditions of the highest possible intra-abdominal pressure, they examined the mesh behavior within the groin and its ability to dislocate under the forces generated by this pressure. The experiment involved six spatial implants and one flat macroporous mesh. RESULTS Heavyweight spatial meshes and lightweight spatial-individualized meshes showed no tendency to dislocate or move directly to the orifice, which was considered a rapid hernia recurrence. Lightweight meshes, both spatial and flat, underwent significant migration and shifting toward the hernial orifices. CONCLUSION Based on the results, we believe that mesh fixation is not the only alternative to preventing recurrence in complex defects. Similar effects can be achieved using a larger, more rigid, and anatomically fitted implant. The type of implant (rather than its fixation) seems to be a key factor from the point of view of mechanics and biophysics. Clinical trials confirming the results in vivo will allow to supplement or amend the guidelines for the treatment of large inguinal hernias.
Collapse
|
10
|
Oprea V, Toma M, Grad O, Bucuri C, Pavel P, Chiorescu S, Moga D. The outcomes of open anterior component separation versus posterior component separation with transversus abdominis release for complex incisional hernias: a systematic review and meta-analysis. HERNIA : THE JOURNAL OF HERNIAS AND ABDOMINAL WALL SURGERY 2023; 27:503-517. [PMID: 36729336 DOI: 10.1007/s10029-023-02745-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 01/15/2023] [Indexed: 02/03/2023]
Abstract
PURPOSE The main objective was to assess the prevalence of hernia recurrence, wound complications (surgical site infections [SSI], seroma and hematoma) and mortality after anterior component separation (ACS) and posterior component separation via transversus abdominis muscle release (PCSTAR) in patients with complex incisional hernias. The so-called complex IH is a serious medical and societal challenge due to its direct and indirect costs; it is also hampered by the use of different surgical techniques, different type of meshes, and different results heterogeneously reported and interpreted. According to actual data, the best approach seems to be a mesh reinforcement component separation procedure augmented or not with an adjuvant technique (preoperative progressive pneumoperitoneum and/or Botulin toxin type A infiltration). METHODS A systematic search of four databases (MEDLINE, PubMed, Web of Science, and Google Scholars) was conducted to identify studies reporting on outcomes of component separation techniques and which were published before December 2021. A systematic review and a meta-analysis of postoperative outcomes were performed. RESULTS Nineteen studies including 3412 patients (1709 with ACS and 1703 with PCSTAR) were selected. Pooled hernia recurrence rate after a minimum 1-year follow-up was evaluated at 5.15% (odds ratio [OR] 0.68; 95% confidence interval [CI] 0.5-0.9; p = 0.0175). Pooled surgical site infection rate was 10.6% (OR 1.32; 95% CI 1.06-1.65; p = 0.0119). Seroma and hematoma were estimated at 9.75% (OR 1.93; 95% CI 1.52-2.44; p = 0.0001) and 3.83% (OR 1.81; 95% CI 1.26-2.61; p = 0.0012), respectively. ACS was associated with increased wound morbidity, seroma and hematoma. PCSTAR displayed higher recurrence rate (4.27% vs 6.11%). CONCLUSIONS PCSTAR was superior to ACS in terms of wound morbidity, surgical site infections, seroma and hematoma incidence. The procedure should be further evaluated in comparative head-to-head randomized controlled trials.
Collapse
Affiliation(s)
- V Oprea
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, No 22 Gral Traian Mosoiu Street, Cluj-Napoca, Cluj County, Romania. .,Second Department of Surgery, Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.
| | - M Toma
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, No 22 Gral Traian Mosoiu Street, Cluj-Napoca, Cluj County, Romania
| | - O Grad
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, No 22 Gral Traian Mosoiu Street, Cluj-Napoca, Cluj County, Romania.,Second Department of Surgery, Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - C Bucuri
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, No 22 Gral Traian Mosoiu Street, Cluj-Napoca, Cluj County, Romania.,Second Department of Surgery, Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - P Pavel
- Clinical Department of Surgery, "Constantin Papilian" Emergency Clinical Military Hospital, No 22 Gral Traian Mosoiu Street, Cluj-Napoca, Cluj County, Romania
| | - S Chiorescu
- Second Department of Surgery, Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - D Moga
- Department of Surgery, "Alexandru Augustin" Emergency Military Hospital, Sibiu, Romania.,Medicine and Pharmacy Faculty, "Lucian Blaga" University, Sibiu, Romania
| |
Collapse
|
11
|
Lauro E, Corridori I, Luciani L, Di Leo A, Sartori A, Andreuccetti J, Trojan D, Scudo G, Motta A, Pugno NM. Stapled fascial suture: ex vivo modeling and clinical implications. Surg Endosc 2022; 36:8797-8806. [PMID: 35578046 DOI: 10.1007/s00464-022-09304-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 04/23/2022] [Indexed: 01/06/2023]
Abstract
BACKGROUND Recently, in the field of abdominal wall repair surgery, some minimally invasive procedures introduced the use of staplers to provide a retromuscular prosthetic repair. However, to the knowledge of the authors, there are little data in the literature about the outcomes of stapled sutures adoption for midline reconstruction. This study aims to investigate the biomechanics of stapled sutures, simple (stapled), or oversewn (hybrid), in comparison with handsewn suture. From the results obtained, we tried to draw indications for their use in a clinical context. METHODS Human cadaver fascia lata specimens, sutured (handsewn, stapled, or hybrid) or not, underwent tensile tests. The data on strength (maximal stress), ultimate strain (deformability), Young's modulus (rigidity), and dissipated specific energy (ability to absorb mechanical energy up to the breaking point) were recorded for each type of specimens and analyzed. RESULTS Stapled and hybrid suture showed a significantly higher strength (handsewn 0.83 MPa, stapled 2.10 MPa, hybrid 2.68 MPa) and a trend toward a lower ultimate strain as compared to manual sutures (handsewn 344%, stapled 249%, hybrid 280%). Stapled and hybrid sutures had fourfold higher Young's modulus as compared to handsewn sutures (handsewn 1.779 MPa, stapled 7.374 MPa, hybrid 6.964 MPa). Handsewn and hybrid sutures showed significantly higher dissipated specific energy (handsewn 0.99 mJ-mm3, stapled 0.73 mJ-mm3, hybrid 1.35 mJ-mm3). CONCLUSION Stapled sutures can resist high loads, but are less deformable and rigid than handsewn suture. This suggests a safer employment in case of small defects or diastasis (< W1 in accord to EHS classification), where the presumed tissutal displacement is minimal. Oversewing a stapled suture improves its efficiency, becoming crucial in case of larger defects (> W1 in accord to EHS classification) where the expected tissutal displacement is maximal. Hybrid sutures seem to be a good compromise.
Collapse
Affiliation(s)
- Enrico Lauro
- Department of General Surgery, St. Maria Del Carmine Hospital, Rovereto, Italy.
| | - Ilaria Corridori
- Laboratory for Bioinspired, Bionic, Nano, Meta Materials and Mechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy
- BIOtech Center for Biomedical Technologies, Department of Industrial Engineering, University of Trento, Trento, Italy
| | - Lorenzo Luciani
- Robotic Unit and Department of Urology, Santa Chiara Hospital, Trento, Italy
| | - Alberto Di Leo
- Department of General Surgery, San Camillo Hospital, Trento, Italy
| | - Alberto Sartori
- Department of General Surgery, Montebelluna-Castelfranco Veneto Hospital, Treviso, Italy
| | - Jacopo Andreuccetti
- Department of General Surgery 2^, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Diletta Trojan
- Fondazione Banca dei Tessuti Treviso FBTV, Treviso, Italy
| | - Giovanni Scudo
- Department of General Surgery, St. Maria Del Carmine Hospital, Rovereto, Italy
| | - Antonella Motta
- BIOtech Center for Biomedical Technologies, Department of Industrial Engineering, University of Trento, Trento, Italy
| | - Nicola M Pugno
- Laboratory for Bioinspired, Bionic, Nano, Meta Materials and Mechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy.
- School of Engineering and Material Science, Queen Mary University of London, London, UK.
| |
Collapse
|
12
|
Lesch C, Uhr K, Vollmer M, Raschidi R, Nessel R, Kallinowski F. Standardized suturing can prevent slackening or bursting suture lines in midline abdominal incisions and defects. Hernia 2022; 26:1611-1623. [PMID: 35997898 PMCID: PMC9684257 DOI: 10.1007/s10029-022-02659-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 07/20/2022] [Indexed: 12/02/2022]
Abstract
Purpose Incisional hernias often follow open abdominal surgery. A small-stitch–small-bite suture might close the incision durably. We analyzed specific details of this closure technique and assessed their influence on the closure stability. Methods The effects of cyclic loads, simulating coughs were investigated on a bench test. We prepared porcine bellies in the median line and bovine flanks parallel to the muscle fibers with 15 cm long incisions. Then we punched round or rhomboid defects with a diameter of 5–10 cm into the center of the incision. Monomax® 2–0 and Maxon® 1 and 2–0 were used as suture materials. We tested the durability of the closure with pressure impacts of 210 mmHg repeated 425 times. Throughout the experiments, we modified the suturing technique, the surgeon, the tissue tension, the defect size and shape and the suture diameter. Results Standardizing the suture technique improved the durability of the closure significantly. Any other variations showed minor influences after standardization. All incisions with round defects up to 7.5 cm width withstood 425 impacts using standardized suturing. Unstandardized sutures failed in all cases. When closing an incision with a 10 cm wide defect, the tissues ruptured frequently next to the suture line. We defined criteria to standardize this suturing technique. For the first time, we developed a suture factor related to the durability of a sutured tissue closure. We integrated the suture factor into the concept of biomechanically durable repairs. Conclusions Suturing the abdominal wall with a standardized suturing technique improves its durability significantly.
Collapse
Affiliation(s)
- C Lesch
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
| | - K Uhr
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany
| | - M Vollmer
- Hamburg University of Technology, Biomechanics, Denickestrasse 15, 21073, Hamburg, Germany
| | - R Raschidi
- Department Allgemein- Und Viszeralchirurgie, Spital Walenstadt, St. Gallen, Switzerland
| | - R Nessel
- General, Visceral and Pediatric Surgery, Klinikum Am Gesundbrunnen, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany
| | - F Kallinowski
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany
| |
Collapse
|
13
|
El Boghdady M, Ewalds-Kvist BM, Laliotis A. Abdominal hernia mesh repair in patients with inflammatory bowel disease: A systematic review. Langenbecks Arch Surg 2022; 407:2637-2649. [PMID: 35947216 PMCID: PMC9640397 DOI: 10.1007/s00423-022-02638-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 07/30/2022] [Indexed: 11/28/2022]
Abstract
Background Postoperative hernia-repair complications are frequent in patients with inflammatory bowel disease (IBD). This fact challenges surgeons’ decision about hernia mesh management in these patients. Therefore, we systematically reviewed the hernia mesh repair in IBD patients with emphasis on risk factors for postoperative complications. Method A systematic review was done in compliance with the PRISMA guidelines. A search was carried out on PubMed and ScienceDirect databases. English language articles published from inception to October 2021 were included in this study. MERSQI scores were applied along with evidence grades in agreement with GRADE’s recommendations. The research protocol was registered with PROSPERO (CRD42021247185). Results The present systematic search resulted in 11,243 citations with a final inclusion of 10 citations. One paper reached high and 4 moderate quality. Patients with IBD exhibit about 27% recurrence after hernia repair. Risk factors for overall abdominal septic morbidity in Crohn’s disease comprised enteroprosthetic fistula, mesh withdrawals, surgery duration, malnutrition biological mesh, and gastrointestinal concomitant procedure. Conclusion Patients with IBD were subject, more so than controls to postoperative complications and hernia recurrence. The use of a diversity of mesh types, a variety of position techniques, and several surgical choices in the citations left room for less explicit and more implicit inferences as regards best surgical option for hernia repair in patients with IBD.
Collapse
Affiliation(s)
- Michael El Boghdady
- Department of General Surgery, Kingston Hospital, London, UK. .,University of Edinburgh, Scotland, UK.
| | | | - Aggelos Laliotis
- Department of General Surgery, Croydon University Hospital, London, UK
| |
Collapse
|
14
|
Kallinowski F, Fortelny RH, Köckerling F, Mayer F, Morales-Conde S, Sandblom G. Editorial: Mesh Complications in Hernia Surgery. Front Surg 2022; 9:841672. [PMID: 35372469 PMCID: PMC8974239 DOI: 10.3389/fsurg.2022.841672] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 01/25/2022] [Indexed: 11/15/2022] Open
Affiliation(s)
- Friedrich Kallinowski
- General, Visceral and Transplantation Surgery, University Hospital, Heidelberg, Germany
| | - René H Fortelny
- General Surgery/Medical Faculty, Sigmund Freud Private University, Vienna, Austria
| | - Ferdinand Köckerling
- Hernia Center, Vivantes Humboldt-Hospital, Charité University Medicine, Berlin, Germany
| | - Franz Mayer
- Department of General, Visceral and Thoracic Surgery, University Hospital Salzburg, Paracelsus Medical University, Salzburg, Austria.,Department of Surgery, General Hospital Hallein, Hallein, Austria
| | - Salvador Morales-Conde
- Unit of Innovation in Minimally Invasive Surgery, University Hospital Virgen del Rocio, University of Sevilla, Sevilla, Spain.,Unit of General and Digestive Surgery, Hospital Quironsalud Sagrado Corazon, Sevilla, Spain
| | - Gabriel Sandblom
- Department of Clinical Science and Education Södersjukhuset, Karolinska Institutet, Stockholm, Sweden.,Department of Surgery, Södersjukhuset, Stockholm, Sweden
| |
Collapse
|
15
|
Nessel R, Löffler T, Rinn J, Lösel P, Voss S, Heuveline V, Vollmer M, Görich J, Ludwig YM, Al-Hileh L, Kallinowski F. Primary and Recurrent Repair of Incisional Hernia Based on Biomechanical Considerations to Avoid Mesh-Related Complications. Front Surg 2022; 8:764470. [PMID: 34977141 PMCID: PMC8714753 DOI: 10.3389/fsurg.2021.764470] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 11/25/2021] [Indexed: 11/13/2022] Open
Abstract
Aim: Mechanical principles successfully guide the construction of polymer material composites in engineering. Since the abdominal wall is a polymer composite augmented with a textile during incisional hernia repair we ask: can incisional hernia be repaired safely and durably based on biomechanical principles? Material and Methods: Repair materials were assessed on a self-built bench test using pulse loads to elude influences on the reconstruction of the abdominal wall. Tissue elasticity was analyzed preoperatively as needed with computed tomography at rest and during Valsalva's maneuver. Preoperatively, the critical retention force of the reconstruction to pulse loads was calculated and a biomechanically durable repair was designed based on the needs of the individual patient. Intraoperatively, the design was adjusted as needed. Hernia meshes with high grip factors (Progrip®, Dahlhausen® Cicat) were used for the repairs. Mesh sizes, fixation elements and reconstructive details were oriented on the biomechanical design. All patients recieved single-shot antibiosis. Patients were discharged after full ambulation was achieved. Results: A total of 163 patients (82 males and 81 females) were treated for incisional hernia in four hospitals by ten surgeons. Primary hernia was repaired in 119 patients. Recurrent hernia was operated on in 44 cases. Recurrent hernia was significantly larger (median 161 cm2 vs. 78 cm2; u-test: p = 0.00714). Re-do surgery took significantly longer (median 229 min vs. 150 min; p < 0.00001) since recurrent disease required more often transversus abdominis release (70% vs. 47%). GRIP tended to be higher in recurrent repair (p = 0.01828). Complication rates (15%) and hospital stay were the same (6 vs. 6 days; p = 0.28462). After 1 year, no recurrence was detected in either group. Pain levels were equally low in both primary and recurrent hernia repairs (median NAS = 0 in both groups at rest and under load, p = 0.88866). Conclusion: Incisional hernia can safely and durably be repaired based on biomechanical principles both in primary and recurrent disease. The GRIP concept provides a base for the application of biomechanical principles in incisional hernia repair.
Collapse
Affiliation(s)
- Regine Nessel
- General, Visceral and Pediatric Surgery, Klinikum Am Gesundbrunnen, Heilbronn, Germany
| | - Thorsten Löffler
- General and Visceral Surgery, Gesundheitszentrum Rhein-Neckar Hospital Eberbach, Eberbach, Germany
| | - Johannes Rinn
- General and Visceral Surgery, Kreiskrankenhaus Bergstrasse Hospital Bergstrasse, Heppenheim, Germany
| | - Philipp Lösel
- Engineering Mathematics and Computing Lab, Interdisciplinary Center for Scientific Computing, Heidelberg, Germany
| | - Samuel Voss
- Laboratory of Fluid Dynamics and Technical Flows, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Vincent Heuveline
- Engineering Mathematics and Computing Lab, Interdisciplinary Center for Scientific Computing, Heidelberg, Germany
| | - Matthias Vollmer
- Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | | | | | - Luai Al-Hileh
- General, Visceral and Pediatric Surgery, Klinikum Am Gesundbrunnen, Heilbronn, Germany
| | - Friedrich Kallinowski
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| |
Collapse
|
16
|
Kallinowski F, Ludwig Y, Gutjahr D, Gerhard C, Schulte-Hörmann H, Krimmel L, Lesch C, Uhr K, Lösel P, Voß S, Heuveline V, Vollmer M, Görich J, Nessel R. Biomechanical Influences on Mesh-Related Complications in Incisional Hernia Repair. Front Surg 2021; 8:763957. [PMID: 34778367 PMCID: PMC8586217 DOI: 10.3389/fsurg.2021.763957] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 09/30/2021] [Indexed: 11/13/2022] Open
Abstract
Aim: Hernia repair strengthens the abdominal wall with a textile mesh. Recurrence and pain indicate weak bonds between mesh and tissue. It remains a question which biomechanical factors strengthen the mesh-tissue interface, and whether surgeons can enhance the bond between mesh and tissue. Material and Methods: This study assessed the strength of the mesh-tissue interface by dynamic loads. A self-built bench test delivered dynamic impacts. The test simulated coughing. Porcine and bovine tissue were used for the bench test. Tissue quality, mesh adhesiveness, and fixation intensity influenced the retention power. The influences were condensed in a formula to assess the durability of the repair. The formula was applied to clinical work. The relative strength of reconstruction was related to the individual human abdominal wall. From computerized tomography at rest and during Valsalva's Maneuver, the tissue quality of the individual patient was determined before surgery. Results: The results showed that biomechanical parameters observed in porcine, bovine, and human tissue were in the same range. Tissues failed in distinct patterns. Sutures slackened or burst at vulnerable points. Both the load duration and the peak load increased destruction. Stress concentrations elevated failure rates. Regional areas of force contortions increased stress concentrations. Hernia repair improved strain levels. Measures for improvement included the closure of the defect, use of higher dynamic intermittent strain (DIS) class meshes, increased mesh overlap, and additional fixation. Surgeons chose the safety margin of the reconstruction as desired. Conclusion: The tissue quality has now been introduced into the concept of a critical and a gained resistance toward pressure-related impacts. A durable hernia repair could be designed from available coefficients. Using biomechanical principles, surgeons could minimize pain levels. Mesh-related complications such as hernia recurrence can potentially be avoided in incisional hernia repair.
Collapse
Affiliation(s)
- Friedrich Kallinowski
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Yannique Ludwig
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Dominik Gutjahr
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Christian Gerhard
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Hannah Schulte-Hörmann
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Lena Krimmel
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Carolin Lesch
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Katharina Uhr
- General, Visceral and Transplantation Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Philipp Lösel
- Engineering Mathematics and Computing Lab (EMCL), Interdisciplinary Center for Scientific Computing, Heidelberg, Germany
| | - Samuel Voß
- Laboratory of Fluid Dynamics and Technical Flows, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Vincent Heuveline
- Engineering Mathematics and Computing Lab (EMCL), Interdisciplinary Center for Scientific Computing, Heidelberg, Germany
| | - Matthias Vollmer
- Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | | | - Regine Nessel
- General, Visceral and Pediatric Surgery, Klinikum Am Gesundbrunnen, Heilbronn, Germany
| |
Collapse
|
17
|
Schaaf S, Schwab R, Güsgen C, Vilz TO, Willms A. Recommendations on Postoperative Activities After Abdominal Operations and Incisional Hernia Repair-A National and International Survey. Front Surg 2021; 8:713138. [PMID: 34660675 PMCID: PMC8511488 DOI: 10.3389/fsurg.2021.713138] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/30/2021] [Indexed: 11/24/2022] Open
Abstract
Background: There is no conclusive data on postoperative recommendations after abdominal and hernia surgery, and there is significant variation in the literature on that question. Thus, this study evaluates the status quo of recommendations of postoperative activity restriction after abdominal surgery. Materials and Methods: A national (German) and international survey of general surgeons on postoperative recommendations after abdominal and hernia surgery was pooled and analyzed. Results: A total of 74.6% recommended postoperative reduced activity for 2 weeks or less after laparoscopy. For midline laparotomy, 48.8% considered a reduced activity of 4 weeks or less to be sufficient. A majority from the national survey recommended more than 4 weeks instead (60.2%), whereas only 31.5% from the international survey did so (p = 0.000). In the pooled analysis, 258 of 450 (57.3%) rated 4 weeks or less suitable. However, the recommendations differed significantly between the surveys (4 weeks or less: a national survey, 47.1% vs. international survey, 64.6%; p = 0.000). Conclusion: There was substantial variation in the given recommendations. However, we found no evidence against immediate mobilization, reduced physical activity, and lifting for up to 2 weeks after laparoscopic surgery and for up to 4 weeks after open abdominal surgery and open incisional/ventral hernia repair in uncomplicated and standard cases. There might be individual and socioeconomic benefits to allow patients to return to their whole personal level of activity and work without putting them at risk of complications. Due to lack of evidence, both retrospective and prospective, controlled studies are in need to develop reliable recommendations.
Collapse
Affiliation(s)
- Sebastian Schaaf
- Department of General, Visceral and Thoracic Surgery, German Armed Forces Central Hospital Koblenz, Koblenz, Germany
| | - Robert Schwab
- Department of General, Visceral and Thoracic Surgery, German Armed Forces Central Hospital Koblenz, Koblenz, Germany
| | - Christoph Güsgen
- Department of General, Visceral and Thoracic Surgery, German Armed Forces Central Hospital Koblenz, Koblenz, Germany
| | - Tim O. Vilz
- Department of General, Visceral, Thoracic and Vasular Surgery, University Hospital Bonn, Bonn, Germany
| | - Arnulf Willms
- Department of General, Visceral and Thoracic Surgery, German Armed Forces Central Hospital Koblenz, Koblenz, Germany
| |
Collapse
|