1
|
Akhlaghian M, Khaledi AA, Mosaddad SA, Dabiri S, Giti R, Kadkhodae F, Gholami S. The internal and marginal adaptation of lithium disilicate endocrowns fabricated using intra and extraoral scanners: An in-vitro study. PLoS One 2024; 19:e0301361. [PMID: 38625957 PMCID: PMC11021016 DOI: 10.1371/journal.pone.0301361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/29/2024] [Indexed: 04/18/2024] Open
Abstract
OBJECTIVES The impression technique highly influences the adaptation of ceramic restorations. Not enough information is available to compare the marginal (MF) and internal fit (IF) of endocrowns fabricated with various digitization techniques. Therefore, this in-vitro study aimed to compare the MF and IF of lithium disilicate (LDS) endocrowns fabricated through direct and indirect digital scanning methods. MATERIALS AND METHODS One extracted maxillary molar was used to fabricate endocrowns. The digitization of the model was performed with (G1) direct scanning (n = 10) utilizing an intraoral scanner (IOS), (G2) indirectly scanning the conventional impression taken from the model using the same IOS (n = 10), (G3) indirectly digitalizing the obtained impression using an extraoral scanner (EOS) (n = 10), and (G4) scanning the poured cast using the same EOS (n = 10). The MF and IF of the endocrowns were measured using the replica method and a digital stereomicroscope. The Kruskal-Wallis test was used to analyze data. RESULTS The studied groups differed significantly (p<0.001). G2 (130.31±7.87 μm) and G3 (48.43±19.14 μm) showed the largest and smallest mean vertical marginal gap, respectively. G2 and G3 led to the highest and lowest internal gaps in all regions, respectively. With significant differences among the internal regions (p<0.001), the pulpal area demonstrated the most considerable misfit in all groups. CONCLUSIONS Scanning the impression using an extraoral scanner showed smaller marginal and internal gaps.
Collapse
Affiliation(s)
- Marzieh Akhlaghian
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Amir-Alireza Khaledi
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Institute of Medical and Technical Sciences, Saveetha Dental College and Hospitals, Saveetha University, Chennai, India
- Faculty of Odontology, Department of Conservative Dentistry and Bucofacial Prosthesis, Complutense University of Madrid, Madrid, Spain
| | - Sana Dabiri
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Rashin Giti
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Farhad Kadkhodae
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Shabnam Gholami
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
2
|
Zhou Y, Fu L, Zhang Z, Tang X. Effect of tooth color on the accuracy of intraoral complete arch scanning under different light conditions using a zirconia restoration model. J Prosthet Dent 2024; 131:145.e1-145.e8. [PMID: 37923645 DOI: 10.1016/j.prosdent.2023.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 10/02/2023] [Accepted: 10/03/2023] [Indexed: 11/07/2023]
Abstract
STATEMENT OF PROBLEM Information regarding the effect of tooth color under different light conditions on the accuracy of intraoral complete arch scanning is limited. PURPOSE The purpose of this in vitro study was to evaluate the effect of color and ambient light conditions on the accuracy of mandibular complete arch scanning with an intraoral scanner (IOS) using a zirconia restoration model with different shades. MATERIAL AND METHODS Five mandible dentition models with zirconia restorations of different shades were fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM). The spectral reflectance and transmittance curves were collected with a spectrophotometer to determine color parameters (Rb, T, S+A, L*, a*, b*, C*, and h). Under 4 different lighting conditions: no light (ZL), natural light (NL), room light (RL), and chair light (CL), each model was scanned 10 times by using an IOS (TRIOS 3). Three-dimensional (3D) deviation analysis and a linear deviation analysis were performed for an accurate quantitative measurement of intraoral scanning. The multivariate test was used to determine significant differences in 3D deviation and linear deviation among groups. The multiple linear regression test was conducted to investigate the relevant independent factors of mean absolute 3D deviation. RESULTS The 3D deviation analysis showed that the mean absolute 3D deviation of 3M2 model scanning was the lowest (P<.001). Moreover, under CL and RL, the accuracy results from the 3M2 model scan were demonstrated as significantly better than the tested scans under other light conditions (P=.021). The result of the linear deviation analysis indicated that the variation in distance was only significant between the bilateral canines (P=.032). Ambient light conditions, C*, and h were factors influencing mean absolute 3D deviation (R2=0.593, P<.001). CONCLUSIONS Color change influenced the accuracy of intraoral mandibular complete arch scanning under different light conditions. This effect may be attributable to the interaction between the ambient light condition and color parameters such as C* and h.
Collapse
Affiliation(s)
- Yong Zhou
- Associate Professor, Department of Dental Implantology, College & Hospital of Stomatology, Anhui Medical University, Key Laboratory of Oral Diseases Research, Hefei, Anhui, PR China
| | - Lijuan Fu
- Graduate student, College & Hospital of Stomatology, Anhui Medical University, Key Laboratory of Oral Diseases Research, Hefei, Anhui, PR China
| | - Zhoujing Zhang
- Graduate student, College & Hospital of Stomatology, Anhui Medical University, Key Laboratory of Oral Diseases Research, Hefei, Anhui, PR China
| | - Xuyan Tang
- Associate Professor, Department of Prosthodontics, College & Hospital of Stomatology, Anhui Medical University, Key Laboratory of Oral Diseases Research, Hefei, Anhui, PR China..
| |
Collapse
|
3
|
Hardan L, Bourgi R, Lukomska-Szymanska M, Hernández-Cabanillas JC, Zamarripa-Calderón JE, Jorquera G, Ghishan S, Cuevas-Suárez CE. Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies. J Adv Prosthodont 2023; 15:315-332. [PMID: 38205120 PMCID: PMC10774636 DOI: 10.4047/jap.2023.15.6.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 11/28/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024] Open
Abstract
PURPOSE This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, Strasbourg, France
| | | | - Juan Carlos Hernández-Cabanillas
- Health Sciences Faculty, Autonomous University of Baja California, Blvd Universitario 1000 Valle de Las Palmas, Tijuana, B.C. Mexico
| | - Juan Eliezer Zamarripa-Calderón
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| | - Gilbert Jorquera
- Department of Prosthodontics, Universidad de los Andes, Santiago, Chile
| | | | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| |
Collapse
|
4
|
Daccache E, Yared CAG, Nasr L, Laawand G, Tohme H. Effect of stabilization of patients on the accuracy and scanning time of maxillary dentate quadrants: A clinical study. J Prosthet Dent 2023:S0022-3913(23)00638-8. [PMID: 39492043 DOI: 10.1016/j.prosdent.2023.09.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/11/2023] [Accepted: 09/11/2023] [Indexed: 11/05/2024]
Abstract
STATEMENT OF PROBLEM As intraoral scanning has gained widespread acceptance as an alternative to conventional impression-making, numerous studies have evaluated the influence of operator-related factors and patient-related factors on scanning accuracy. While several authors have noted patient movements as a clinical limitation of scanning technologies, research providing empirical data or testing this hypothesis is lacking. PURPOSE The purpose of this clinical study was to assess the effect of using the Zero Motion Scanning Band, a silicone occlusal mouth prop, and an OptraGate lip retractor for stabilizing the head and jaw on the accuracy (trueness and precision) and scanning time of digital quadrant scans. MATERIAL AND METHODS A conventional impression was made of the maxillary right quadrant with polyvinyl siloxane material and then digitized using a calibrated extraoral scanner to create the reference file. Two different groups were created: no scanning aids (NSA) and with scanning aids (WSA). For the NSA group, scans were made without considering the participant's movements. For the WSA group, scans included the Zero Motion Scanning Band, a silicone occlusal mouth prop, and an OptraGate lip retractor. Sixty-four scans were captured with an intraoral scanner (TRIOS 3) for each group, and the scanning time was recorded. Using an inspection and metrology software program, scans of each group were superimposed on the reference file to determine 3-dimensional (3D) deviations. The Kolmogorov-Smirnov test evaluated the normality of the distribution of variables, and the Mann-Whitney U test was selected for data analysis of non-normally distributed variables, including 3D deviations and scanning time (α=.05). RESULTS Significant differences for trueness and scanning time mean values were observed under different scanning conditions: with and without head and jaw positioning (P<.05). The modified scan protocol exhibited higher trueness, with smaller mean root mean square values of 38.4 ±2.7 µm compared with 40.8 ±3.1 µm in the nonmodified group. However, precision did not display a statistically significant difference with varying scanning conditions (P>.05). CONCLUSIONS The use of the Zero Motion Scanning Band, a lip retractor, and a silicone occlusal mouth prop on the contralateral side of the scanned quadrant significantly improved the trueness and scanning time of the quadrant digital scan. Further evaluation of head and jaw stabilizing tools is recommended in more complex clinical scenarios, such as complete arch digital scans and scanning implant-supported restorations.
Collapse
Affiliation(s)
- Elia Daccache
- Postgraduate student, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon.
| | - Carole Abi Ghosn Yared
- Director of Postgraduate Program, Department of Removable Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Lara Nasr
- Co-Director of Oral Health Unit, Cranio-facial Research Laboratory, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Ghida Laawand
- Clinical Instructor, Department of Removable and Fixed Prosthodontics, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Hani Tohme
- Founder and Head of Digital Dentistry, AI and Evolving Technologies Department, Former Head of Removable Prosthodontics Department, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| |
Collapse
|
5
|
Alkadi L. A Comprehensive Review of Factors That Influence the Accuracy of Intraoral Scanners. Diagnostics (Basel) 2023; 13:3291. [PMID: 37958187 PMCID: PMC10650453 DOI: 10.3390/diagnostics13213291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/19/2023] [Accepted: 10/22/2023] [Indexed: 11/15/2023] Open
Abstract
Intraoral scanners (IOSs) have become increasingly popular in the field of dentistry for capturing accurate digital impressions of patients' teeth and oral structures. This study investigates the various factors influencing their accuracy. An extensive search of scholarly literature was carried out via PubMed, utilizing appropriate keywords. Factors evaluated in the included studies were categorized into three primary divisions: those related to the operator, the patient, and the IOS itself. The analysis demonstrated that the accuracy of intraoral scanning is influenced by various factors such as scanner selection, operator skill, calibration, patient's oral anatomy, ambient conditions, and scanning aids. Maintaining updated software and understanding factors beyond scanner resolution are crucial for optimal accuracy. Conversely, smaller IOS tips, fast scanning speeds, and specific scanning patterns compromise the accuracy and precision. By understanding these factors, dental professionals can make more informed decisions and enhance the accuracy of IOSs, leading to improved final dental restorations.
Collapse
Affiliation(s)
- Lubna Alkadi
- Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, National Guard Health Affairs, Riyadh 11426, Saudi Arabia;
- King Abdullah International Medical Research Center, National Guard Health Affairs, Riyadh 11481, Saudi Arabia
| |
Collapse
|
6
|
Sequeira V, Harper MT, Lilly CL, Bryington MS. Accuracy of Digital Impressions at Varying Implant Depths: An In Vitro Study. J Prosthodont 2023; 32:54-61. [PMID: 35191128 DOI: 10.1111/jopr.13496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 02/08/2022] [Indexed: 01/25/2023] Open
Abstract
PURPOSE Implants placed at variable depths may vary the amount of visible scannable surface of a scan body. Intraoral scanner technology uses advanced optical principles to record the surface of the scan body to accurately capture the implant position. The purpose of this study is to investigate the effect implant placement depth has on the accuracy of digital implant impressions using an intraoral scanner. MATERIALS AND METHODS A partially edentulous gypsum master model was fabricated to allow the positioning of a single implant analog at different depths. Four groups were created based on the planned implant depths of 7, 6, 3, and 0 mm and corresponding visibility of the scan body at 2, 3, 6, and 9 mm. The model was digitized with a laboratory scanner for the reference scan and with an intraoral scanner to generate 15 test scans per group, with a total of 60 scans. The test scans were superimposed onto the reference scan using the best fit algorithm to analyze and measure the positional (dXYZ) and angular deviation (d⍬) of the scan body using three-dimensional metrology software. Statistical analysis was performed using a one-way ANOVA and pairwise comparison was done with a Tukey-Kramer HSD test (α = 0.05). RESULTS The one-way ANOVA of the groups for the dXYZ and dθ parameters was statistically significant (F3,56 = 11.45, p < 0.001, F3,56 = 24.04, p < 0.001). Group D (9 mm) showed the least positional deviation at 38.41 μm (95% CI 30.26; 46.56) and the least angular deviation of 0.17° (95% CI 0.12; 0.21). Group A (2 mm) showed the greatest positional deviation of 77.17 μm (95% CI 65.23; 89.11) and greatest angular deviation of 0.84° (95% CI 0.65; 1.03). The positional and angular deviation increased with increased implant depth. CONCLUSIONS The accuracy of digital impressions is influenced by the implant depth and the amount of visibility of the scan body. The trueness and precision are highest when the implant is placed at 0 mm depth with complete visibility of the scan body and decreases with subgingival implant placement.
Collapse
Affiliation(s)
- Vivia Sequeira
- Department of Restorative Dentistry, School of Dentistry, West Virginia University, Morgantown, WA
| | - Matthew T Harper
- Department of Restorative Dentistry, School of Dentistry, West Virginia University, Morgantown, WA
| | - Christa L Lilly
- Department of Epidemiology and Biostatistics, School of Public Health, West Virginia University, Morgantown, WA
| | - Matthew S Bryington
- Department of Restorative Dentistry, School of Dentistry, West Virginia University, Morgantown, WA
| |
Collapse
|
7
|
Son YT, Son K, Lee KB. Trueness of intraoral scanners according to subgingival depth of abutment for fixed prosthesis. Sci Rep 2022; 12:20786. [PMID: 36456561 PMCID: PMC9715536 DOI: 10.1038/s41598-022-23498-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 11/01/2022] [Indexed: 12/03/2022] Open
Abstract
This study aimed to compare the trueness of intraoral scanners (IOSs) according to the subgingival finish line depth of tooth preparation for fixed prostheses. The prepared maxillary right first molar was fabricated by using ceramic material. A computer-aided design (CAD) reference model (CRM) of the abutment was obtained by using a contact scanner. The subgingival finish line was located according to the depth at 0-mm, 0.25-mm, 0.5-mm, 0.75-mm, and 1-mm. CAD test models (CTMs) were obtained by using 2 IOSs (i500 and CS3600). CRM and CTM were superimposed and analyzed (Geomagic control X). The one-way analysis of variance (ANOVA) was used to compare the trueness according to the subgingival finish line depth. The paired t test was used to compare the trueness of IOSs with and without gingival retraction (α = .05). When the gingival displacement code was not used, it was observed that the trueness of both IOSs decreased significantly as the depth of the subgingival finish line increased (P < 0.001). When the subgingival finish line was positioned deeper than 0.5-mm, the trueness of both IOSs exceeded 100 µm in the marginal region. When the gingival displacement cord was used, the trueness of both IOSs did not exceed 100 µm regardless of the subgingival finish line depth. When gingival cord was used, it showed significantly higher trueness than when not used (P < 0.001). When the gingival displacement cord was not used, the trueness of IOSs decreased as the subgingival finish line depth increased. But the use of the gingival displacement cord improved the scanning trueness by 90%. Thus, it is necessary to use the gingival displacement cord according to the clinical situation to improve scan trueness at the subgingival finish line.
Collapse
Affiliation(s)
- Young-Tak Son
- grid.258803.40000 0001 0661 1556Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea ,grid.258803.40000 0001 0661 1556Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea
| | - KeunBaDa Son
- grid.258803.40000 0001 0661 1556Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea
| | - Kyu-Bok Lee
- grid.258803.40000 0001 0661 1556Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea ,grid.258803.40000 0001 0661 1556Department of Prosthodontics, School of Dentistry, Advanced Dental Device Development Institute, Kyungpook National University, 2177 Dalgubuldaero, Jung-Gu, Daegu, 41940 Republic of Korea
| |
Collapse
|
8
|
Hashemi AM, Hashemi HM, Siadat H, Shamshiri A, Afrashtehfar KI, Alikhasi M. Fully Digital versus Conventional Workflows for Fabricating Posterior Three-Unit Implant-Supported Reconstructions: A Prospective Crossover Clinical Trial. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph191811456. [PMID: 36141729 PMCID: PMC9517085 DOI: 10.3390/ijerph191811456] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/07/2022] [Accepted: 09/08/2022] [Indexed: 05/14/2023]
Abstract
This study assessed the clinical variables influencing the success of three-unit implant-supported fixed dental prostheses (ISFDPs) fabricated using either fully digital or conventional workflows. The clinical trial evaluated 10 patients requiring three-unit ISFDPs in the posterior mandible. Maxillomandibular relation records, and digital and conventional impressions were obtained from each patient using an intraoral scanner (IoS) and polyvinylsiloxane (PVS), and the frameworks were fabricated using zirconia and cobalt-chromium, respectively. A 2 µm accuracy scanner scanned the conventional master casts and standard reference models. The stereolithography (STL) files of the digital and conventional impressions were superimposed on the standard model file, and the accuracy was calculated with the best-fit algorithm. The framework adaptation and passivity were assessed using the one-screw and screw resistance tests. The time required for occlusal adjustment of both types of reconstructions, including the duration of the whole treatment, was recorded. The aesthetic appearance of ISFDPs was rated by each patient and clinician using a self-administered visual analogue scale questionnaire and the FDI World Dental Federation aesthetic parameters, respectively. The sample size was based on the power calculation, and alpha was set at 0.05 for the statistical analyses. The impression accuracy, framework adaptation and passivity, and reconstructions aesthetics did not significantly differ between the digital and conventional approaches. The total fabrication time was significantly shorter using the digital workflow. Within the limitations of this clinical study, the fully digital workflow can be used for the fabrication of ISFDPs with a clinical outcome comparable to that of the conventional workflow.
Collapse
Affiliation(s)
- Ali Mahmoud Hashemi
- Dental Implant Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran 1417614411, Iran
| | - Hamid Mahmoud Hashemi
- Dental Implant Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran 1417614411, Iran
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Tehran University of Medical Sciences, Tehran 1411713135, Iran
| | - Hakimeh Siadat
- Dental Implant Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran 1417614411, Iran
- Department of Prosthodontics, Tehran University of Medical Sciences, Tehran 1411713135, Iran
| | - Ahmadreza Shamshiri
- Department of Epidemiology and Biostatistics, School of Public Health and Institute of Public Health Research, Tehran University of Medical Sciences, Tehran 1417614411, Iran
| | - Kelvin Ian Afrashtehfar
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, Faculty of Medicine, University of Bern, 3010 Berne, Switzerland
- Division of Restorative Dental Sciences, Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City P.O. Box 346, United Arab Emirates
- Correspondence: (K.I.A.); (M.A.)
| | - Marzieh Alikhasi
- Dental Implant Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran 1417614411, Iran
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Tehran University of Medical Sciences, Tehran 1411713135, Iran
- Correspondence: (K.I.A.); (M.A.)
| |
Collapse
|
9
|
Di Venere D, Laforgia A, Azzollini D, Barile G, De Giacomo A, Inchingolo AD, Rapone B, Capodiferro S, Kazakova R, Corsalini M. Calcification of the Atlanto-Occipital Ligament (Ponticulus Posticus) in Orthodontic Patients: A Retrospective Study. Healthcare (Basel) 2022; 10:healthcare10071234. [PMID: 35885761 PMCID: PMC9319085 DOI: 10.3390/healthcare10071234] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 06/09/2022] [Accepted: 06/30/2022] [Indexed: 11/17/2022] Open
Abstract
Background: Ponticlus Posticus (PP) is a rare anomaly of the first cervical vertebra easily identifiable in lateral cephalometric radiograph and typically required for orthodontic diagnosis. The aim of this study is to evaluate the PP prevalence in lateral Cephalograms in a cohort of orthodontic patients treated at the Dental School of the University of Bari ‘Aldo Moro’, Italy, and to find possible connection between PP and other dental anomalies, as well as the patient’s cephalometric characteristics. Methods: A total of 150 panoramic radiographs and 150 lateral Cephalograms, obtained for orthodontic use only, were evaluated. No patients were referred to for congenital syndromes or disease, or a history of previously occurred maxillofacial trauma. A detailed cephalometric study was performed for each patient, and the whole cohort was divided according to the common three dental malocclusion classes. The values obtained were analyzed using the Chi-Square Test. Results: PP prevalence was 8% (12 of 150 cases), where the complete and partial forms observed 4.7% and 3.3%, respectively. Although females were more affected (9.6%), no statistically significant sex-related difference was found. Furthermore, no statistically significant relationship regarding age or dental anomalies (dental agenesis/palatal impacted canines) among the groups was observed either. Cephalometric analyses revealed that half of the subjects with PP were sagittal skeletal class I and had vertical hyper-divergence. Conclusions: PP is a frequent anatomical variation of the cervical vertebra, apparently unrelated to the skeletal malocclusion type or dental anomalies. The current study needs to further confirm the congenital hypothesis of PP’s origin already reported in literature.
Collapse
Affiliation(s)
- Daniela Di Venere
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Alessandra Laforgia
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Daniela Azzollini
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Giuseppe Barile
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
- Correspondence: (G.B.); (M.C.)
| | - Andrea De Giacomo
- Department of Basic Medical Sciences, Neurosciences and Sense Organs, University of Bari ‘Aldo Moro’, 70124 Bari, Italy;
| | - Alessio Danilo Inchingolo
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Biagio Rapone
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Saverio Capodiferro
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University—Plovdiv, 4002 Plovdiv, Bulgaria;
| | - Massimo Corsalini
- Interdisciplinary Department of Medicine, University of Bari ‘Aldo Moro’, 70121 Bari, Italy; (D.D.V.); (A.L.); (D.A.); (A.D.I.); (B.R.); (S.C.)
- Correspondence: (G.B.); (M.C.)
| |
Collapse
|
10
|
Inchingolo AD, Malcangi G, Inchingolo AM, Piras F, Settanni V, Garofoli G, Palmieri G, Ceci S, Patano A, De Leonardis N, Di Pede C, Montenegro V, Azzollini D, Garibaldi MG, Kruti Z, Tarullo A, Coloccia G, Mancini A, Rapone B, Semjonova A, Hazballa D, D’Oria MT, Jones M, Macchia L, Bordea IR, Scarano A, Lorusso F, Tartaglia GM, Maspero C, Del Fabbro M, Nucci L, Ferati K, Ferati AB, Brienza N, Corriero A, Inchingolo F, Dipalma G. Benefits and Implications of Resveratrol Supplementation on Microbiota Modulations: A Systematic Review of the Literature. Int J Mol Sci 2022; 23:4027. [PMID: 35409389 PMCID: PMC8999966 DOI: 10.3390/ijms23074027] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 03/24/2022] [Accepted: 03/31/2022] [Indexed: 01/27/2023] Open
Abstract
Resveratrol is a polyphenol that has been shown to possess many applications in different fields of medicine. This systematic review has drawn attention to the axis between resveratrol and human microbiota, which plays a key role in maintaining an adequate immune response that can lead to different diseases when compromised. Resveratrol can also be an asset in new technologies, such as gene therapy. PubMed, Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to find papers that matched our topic dating from 1 January 2017 up to 18 January 2022, with English-language restriction using the following Boolean keywords: ("resveratrol" AND "microbio*"). Eighteen studies were included as relevant papers matching the purpose of our investigation. Immune response, prevention of thrombotic complications, microbiota, gene therapy, and bone regeneration were retrieved as the main topics. The analyzed studies mostly involved resveratrol supplementation and its effects on human microbiota by trials in vitro, in vivo, and ex vivo. The beneficial activity of resveratrol is evident by analyzing the changes in the host's genetic expression and the gastrointestinal microbial community with its administration. The possibility of identifying individual microbial families may allow to tailor therapeutic plans with targeted polyphenolic diets when associated with microbial dysbiosis, such as inflammatory diseases of the gastrointestinal tract, degenerative diseases, tumors, obesity, diabetes, bone tissue regeneration, and metabolic syndrome.
Collapse
Affiliation(s)
- Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Giuseppina Malcangi
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Fabio Piras
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Vito Settanni
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Grazia Garofoli
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Giulia Palmieri
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Sabino Ceci
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Assunta Patano
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Nicole De Leonardis
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Chiara Di Pede
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Valentina Montenegro
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Daniela Azzollini
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Maria Grazia Garibaldi
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Zamira Kruti
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Antonella Tarullo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Giovanni Coloccia
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Antonio Mancini
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Biagio Rapone
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Alexandra Semjonova
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Denisa Hazballa
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
- Kongresi Elbasanit, Aqif Pasha, Rruga, 3001 Elbasan, Albania
| | - Maria Teresa D’Oria
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
- Department of Medical and Biological Sciences, University of Udine, Via delle Scienze, 206, 33100 Udine, Italy
| | - Megan Jones
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Luigi Macchia
- Department of Emergency and Organ Transplantation (D.E.T.O.), University of Bari “Aldo Moro”, 70121 Bari, Italy;
| | - Ioana Roxana Bordea
- Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
| | - Antonio Scarano
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Gianluca Martino Tartaglia
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20122 Milan, Italy; (G.M.T.); (C.M.); (M.D.F.)
- UOC Maxillo-Facial Surgery and Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Cinzia Maspero
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20122 Milan, Italy; (G.M.T.); (C.M.); (M.D.F.)
- UOC Maxillo-Facial Surgery and Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20122 Milan, Italy; (G.M.T.); (C.M.); (M.D.F.)
- IRCCS Orthopedic Institute Galeazzi, 20161 Milan, Italy
| | - Ludovica Nucci
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Via Luigi de Crecchio, 6, 80138 Naples, Italy;
| | - Kenan Ferati
- Faculty of Medical Sciences, University of Tetovo, 1220 Tetovo, North Macedonia; (K.F.); (A.B.F.)
| | - Arberesha Bexheti Ferati
- Faculty of Medical Sciences, University of Tetovo, 1220 Tetovo, North Macedonia; (K.F.); (A.B.F.)
| | - Nicola Brienza
- Unit of Anesthesia and Resuscitation, Department of Emergencies and Organ Transplantations, Aldo Moro University, 70124 Bari, Italy; (N.B.); (A.C.)
| | - Alberto Corriero
- Unit of Anesthesia and Resuscitation, Department of Emergencies and Organ Transplantations, Aldo Moro University, 70124 Bari, Italy; (N.B.); (A.C.)
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy; (A.D.I.); (G.M.); (A.M.I.); (F.P.); (V.S.); (G.G.); (G.P.); (S.C.); (A.P.); (N.D.L.); (C.D.P.); (V.M.); (D.A.); (M.G.G.); (Z.K.); (A.T.); (G.C.); (A.M.); (B.R.); (A.S.); (D.H.); (M.T.D.); (M.J.); (F.I.); (G.D.)
| |
Collapse
|
11
|
Profilometer Comparison of the Surface Roughness of Four Denture Base Resins: An In Vitro Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12041837] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background: The roughness of denture base materials is mainly affected by inherent material features, the polishing technique, and the operator’s manual skills. The surface irregularities of the denture base resin’s roughness profile is one of the components characterizing the superficial topography of dental prostheses, and it is a critical parameter for describing surface morphology. Generally, the increment of the surface roughness minimizes cleanability and promotes the rate of bacterial adherence, affecting the expression of bacterial adhesins. The purpose of this in vitro study was to investigate the roughness of four commercially available denture base resins employed for removable prosthodontics. Methods: Twenty-five specimens were realized and submitted to observation for three dimensions (vertically, horizontally, 45°). Average surface roughness (Ra), Rv, Rp, and Rq were measured with a calibrated mechanical roughness tester (Taylor Hobson Surtronic 25; Taylor Hobson, Leicester, UK). Data were analyzed through a Kruskal–Wallis test. Results: Significant differences in Ra between the groups were assessed. Baltic Denture System™ (Merz Dental GmbH; Lütjenburg, Germania) showed a lower surface roughness coefficient and a more homogeneous surface. Conclusions: The functional importance of surface roughness parameters for denture base materials must be explored, not only considering recognized surface features.
Collapse
|
12
|
Barenghi L, Barenghi A, Garagiola U, Di Blasio A, Giannì AB, Spadari F. Pros and Cons of CAD/CAM Technology for Infection Prevention in Dental Settings during COVID-19 Outbreak. SENSORS (BASEL, SWITZERLAND) 2021; 22:49. [PMID: 35009586 PMCID: PMC8747329 DOI: 10.3390/s22010049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/13/2021] [Accepted: 12/15/2021] [Indexed: 12/12/2022]
Abstract
The purpose of this commentary is to update the evidence reported in our previous review on the advantages and limitations of computer-aided design/computer-aided manufacturing technology in the promotion of dental business, as well as to guarantee patient and occupational safety. The COVID-19 pandemic led to an unprecedented focus on infection prevention; however, waves of COVID-19 follow one another, asymptomatic cases are nearly impossible to identify by triage in a dental setting, and the effectiveness of long-lasting immune protection through vaccination remains largely unknown. Different national laws and international guidelines (mainly USA-CDC, ECDC) have often brought about dissimilar awareness and operational choices, and in general, there has been very limited attention to this technology. Here, we discuss its advantages and limitations in light of: (a) presence of SARS-CoV-2 in the oral cavity, saliva, and dental biofilm and activation of dormant microbial infections; (b) the prevention of SARS-CoV-2 transmission by aerosol and fomite contamination; (c) the detection of various oral manifestations of COVID-19; (d) specific information for the reprocessing of the scanner tip and the ward from the manufacturers.
Collapse
Affiliation(s)
- Livia Barenghi
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Alberto Barenghi
- Department of Medicine and Surgery, Centro di Odontoiatria, Parma University, 43126 Parma, Italy; (A.B.); (A.D.B.)
| | - Umberto Garagiola
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Alberto Di Blasio
- Department of Medicine and Surgery, Centro di Odontoiatria, Parma University, 43126 Parma, Italy; (A.B.); (A.D.B.)
| | - Aldo Bruno Giannì
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Francesco Spadari
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| |
Collapse
|
13
|
Ellakany P, Tantawi ME, Mahrous AA, Al-Harbi F. Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD/CAM Scanning Technologies: An In Vitro Study. J Prosthodont 2021; 31:314-319. [PMID: 34085355 DOI: 10.1111/jopr.13400] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/01/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare the accuracy of intraoral and extraoral scanners (IOSs and EOSs) with different scanning technologies. MATERIAL AND METHODS A phantom cast was used to simulate the patient's mouth. Polyether impression was made of the phantom cast and poured to fabricate stone casts. The stone casts were scanned by two IOSs (3shape Trios 3, 3S and Dental Wings, DW) and two EOSs (S600 Arti Zirkonzahn, ZK and Ceramill map 600 Amann Girrbach, AG) to obtain digital casts. Reference teeth (canines, premolar, and molars) dimensions were measured on the digital casts by Geomagic software and compared to measurements of the stone cast done by stereomicroscope. The dimensions were occluso-cervical mesio-distal, and bucco-lingual and their average was calculated. Differences between digital and stereoscopic measurements were assessed using paired t-test. Discrepancies between these measurements were calculated as differences and were compared among the four scanners using ANOVA. RESULTS The differences among the discrepancies of the four scanners were not significant overall (p = 0.969), in premolars (p = 0.932) or molars (p = 0.069) but significant in canines (p = 0.025). The discrepancies of the EOSs were ≤0.01 mm in canines and molars. DW had the greatest discrepancy in canines and molars. CONCLUSIONS The IOSs and EOSs had similar accuracy except in canines where EOSs performed better. The accuracy of scanning is affected by the smoothness and regularity of the teeth surfaces as in case of the canine.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maha El Tantawi
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Amr A Mahrous
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
14
|
Marginal and Internal Fit of Ceramic Restorations Fabricated Using Digital Scanning and Conventional Impressions: A Clinical Study. J Clin Med 2020; 9:jcm9124035. [PMID: 33327402 PMCID: PMC7764839 DOI: 10.3390/jcm9124035] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 12/09/2020] [Accepted: 12/11/2020] [Indexed: 11/17/2022] Open
Abstract
This clinical study was designed with the aim of fabricating four ceramic crowns using the conventional method and digital methods with three different intraoral scanners and evaluate the marginal and internal fit as well as clinician satisfaction. We enrolled 20 subjects who required ceramic crowns in the upper or lower molar or the premolar. Impressions were obtained using digital scans, with conventional impressions (polyvinyl siloxane and desktop scanner) and three different intraoral scanners (EZIS PO, i500, and CS3600). Four lithium disilicate glass-ceramic crowns were fabricated for each patient. In the oral cavity, the proximal and occlusal adjustments were performed, and the marginal fit and internal fit were evaluated using the silicone replica technique. The clinician satisfaction score of the four crowns was evaluated as per the evaluations of the proximal and occlusal contacts made during the adjustment process and the marginal and internal fit. For statistical analysis, the differences among the groups were analyzed with one-way analysis of variance and Tukey HSD test as a post-test; Pearson correlation analysis was used for analyzing the correlations (α = 0.05). There was a significant difference in the marginal and internal fit of the ceramic crowns fabricated using three intraoral scanner types and one desktop scanner type (p < 0.001); there was a significant difference in the clinician satisfaction scores (p = 0.04). The clinician satisfaction score and marginal fit were significantly correlated (absolute marginal discrepancy and marginal gap) (p < 0.05). An impression technique should be considered for fabricating a ceramic crown with excellent goodness-of-fit. Further, higher clinician satisfaction could be obtained by reproducing the excellent goodness-of-fit using the intraoral scanning method as compared to the conventional method.
Collapse
|