1
|
Muhammad N, Karim M, Harun H, Rahman M, Azlan R, Sumardi N. The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
2
|
Applications of Medical Physics. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12041852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Since the discovery of X-rays, the use of the principles and methods of physics in medicine has contributed to the improvement of human health [...]
Collapse
|
3
|
Kamal I, Razak HRA, Abdul Karim MK, Mashohor S, Liew JYC, Low YJ, Zaaba NA, Norkhairunnisa M, Rafi NASM. Mechanical and Imaging Properties of a Clinical-Grade Kidney Phantom Based on Polydimethylsiloxane and Elastomer. Polymers (Basel) 2022; 14:polym14030535. [PMID: 35160523 PMCID: PMC8840541 DOI: 10.3390/polym14030535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/08/2021] [Accepted: 12/10/2021] [Indexed: 02/01/2023] Open
Abstract
Medical imaging phantoms are considered critical in mimicking the properties of human tissue for calibration, training, surgical planning, and simulation purposes. Hence, the stability and accuracy of the imaging phantom play a significant role in diagnostic imaging. This study aimed to evaluate the influence of hydrogen silicone (HS) and water (H2O) on the compression strength, radiation attenuation properties, and computed tomography (CT) number of the blended Polydimethylsiloxane (PDMS) samples, and to verify the best material to simulate kidney tissue. Four samples with different compositions were studied, including samples S1, S2, S3, and S4, which consisted of PDMS 100%, HS/PDMS 20:80, H2O/PDMS 20:80, and HS/H2O/PDMS 20:40:40, respectively. The stability of the samples was assessed using compression testing, and the attenuation properties of sample S2 were evaluated. The effective atomic number of S2 showed a similar pattern to the human kidney tissue at 1.50 × 10−1 to 1 MeV. With the use of a 120 kVp X-ray beam, the CT number quantified for S2, as well measured 40 HU, and had the highest contrast-to-noise ratio (CNR) value. Therefore, the S2 sample formulation exhibited the potential to mimic the human kidney, as it has a similar dynamic and is higher in terms of stability as a medical phantom.
Collapse
Affiliation(s)
- Izdihar Kamal
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Hairil Rashmizal Abdul Razak
- Department of Radiology, Faculty of Medicine and Health Sciences, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Muhammad Khalis Abdul Karim
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
- Correspondence: ; Tel.: +60-192140612
| | - Syamsiah Mashohor
- Department of Computer and Communication Systems, Faculty of Engineering, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Josephine Ying Chyi Liew
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Yiin Jian Low
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Nur Atiqah Zaaba
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
- Diagnostic Imaging Services, KPJ Seremban Specialist Hospital, Lot 6219&6220, Jalan Toman 1 Kemayan Square, Seremban 70200, Negeri Sembilan, Malaysia
| | - Mazlan Norkhairunnisa
- Institute of Advanced Technology, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Nur Athirah Syima Mohd Rafi
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
| |
Collapse
|
4
|
Karim M, Harun H, Kayun Z, Aljewaw O, Azizan S, Rafiz N, Muhammad N. Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|