1
|
Shankar D, Jayaganesh K, Gowda N, Lakshmi KS, Jayanthi KJ, Jambagi SC. Thermal spray processes influencing surface chemistry and in-vitro hemocompatibility of hydroxyapatite-based orthopedic implants. BIOMATERIALS ADVANCES 2024; 158:213791. [PMID: 38295645 DOI: 10.1016/j.bioadv.2024.213791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 12/28/2023] [Accepted: 01/23/2024] [Indexed: 03/03/2024]
Abstract
Orthopedic implants made from titanium are a popular choice in the medical field because of their remarkable strength-to-weight ratio. Nevertheless, they may not interact well with human blood, resulting in thrombosis and hemolysis. In fact, non-hemocompatibility is believed to be responsible for about 31 % of medical device failures in the US alone, requiring painful and expensive revision surgery. To address this issue, bioactive hydroxyapatite coatings are applied to Ti-6Al-4V implants using thermal spray techniques. However, the temperature used during thermal processing impacts the coating's surface properties, affecting the mechanical and biological properties. Furthermore, the effectiveness of HA coatings on titanium for orthopedic applications has not been validated by biocompatibility tests, particularly hemocompatibility. In this study, we aimed to investigate the relative efficacy of three thermal spray processes of different temperature ranges: Atmospheric plasma spray (APS) (high temperature), Flame spray (FS) (moderate temperature), and High-Velocity Oxy-Fuel spray (HVOF) (low temperature), and study their impact on coating's surface properties, affecting blood components and implant's strength. The crystallinity of the HA coating increased by 32 % with a decrease in the operating temperature (APS < FS < HVOF). HVOF coating exhibited a ~ 34 % and ~ 120 % improvement in adhesion strength and ~ 31 % and 59 % increment in hardness compared to APS and FS coating, respectively, attributed to its low porosity, low coating thickness (~55 μm), and high degree of crystallinity. The HVOF coating showcased a significant increase in non-hemolytic behavior, with hemolysis rates ~8 and ~ 11 times lower than APS and FS coatings, respectively, owing to its smooth texture and high degree of crystallinity (p < 0.05). Furthermore, the HVOF coating exhibited minimal blood clotting based on the whole blood clotting assay, again confirmed by PT and aPTT assays showing delayed clotting time, indicating its non-thrombogenic behavior. The number of platelets adhered to the three coatings showed no significant difference compared to Ti-6Al-4V. APS and FS coatings showed low platelet activation, unlike HVOF coating and titanium, which revealed round platelets, similar to the negative control. Neither titanium nor HA coatings exhibited antibacterial properties, which may be due to their high affinity for organic substances, which promotes bacterial adhesion and replication. Among the three thermal processes, HVOF coating displayed good apatite growth, non-hemolytic, and non-thrombogenicity with no platelet activation owing to its low processing temperature, high degree of crystallinity (89.7 %), hydrophilicity, smooth (~4 μm) and dense (~97 %) microstructural properties. The results demonstrated that the HVOF-HA coating presented in this work meets the hemocompatible requirements and shows promise for prospective application as an orthopedic implant. Furthermore, this study has the potential to significantly reduce the use of animals in in-vivo research and improve their welfare while also cutting costs.
Collapse
Affiliation(s)
- Deep Shankar
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, 575025 Surathkal, India
| | - K Jayaganesh
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, 575025 Surathkal, India
| | - Niranjan Gowda
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - K S Lakshmi
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - K J Jayanthi
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - Sudhakar C Jambagi
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, 575025 Surathkal, India.
| |
Collapse
|
2
|
Agrafiotis E, Zimpfer D, Mächler H, Holzapfel GA. Review of Systemic Mock Circulation Loops for Evaluation of Implantable Cardiovascular Devices and Biological Tissues. J Endovasc Ther 2024:15266028241235876. [PMID: 38528650 DOI: 10.1177/15266028241235876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
CLINICAL IMPACT On needs-based ex vivo monitoring of implantable devices or tissues/organs in cardiovascular simulators provides new insights and paves new paths for device prototypes. The insights gained could not only support the needs of patients, but also inform engineers, scientists and clinicians about undiscovered aspects of diseases (during routine monitoring). We analyze seminal and current work and highlight a variety of opportunities for developing preclinical tools that would improve strategies for future implantable devices. Holistically, mock circulation loop studies can bridge the gap between in vivo and in vitro approaches, as well as clinical and laboratory settings, in a mutually beneficial manner.
Collapse
Affiliation(s)
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Medical University of Graz, Graz, Austria
| | - Heinrich Mächler
- Division of Cardiac Surgery, Medical University of Graz, Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
3
|
Tu J, Xu L, Li F, Dong N. Developments and Challenges in Durable Ventricular Assist Device Technology: A Comprehensive Review with a Focus on Advancements in China. J Cardiovasc Dev Dis 2024; 11:29. [PMID: 38248899 PMCID: PMC10817065 DOI: 10.3390/jcdd11010029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 01/09/2024] [Accepted: 01/12/2024] [Indexed: 01/23/2024] Open
Abstract
Heart transplantation is currently the most effective treatment for end-stage heart failure; however, the shortage in donor hearts constrains the undertaking of transplantation. Mechanical circulatory support (MCS) technology has made rapid progress in recent years, providing diverse therapeutic options and alleviating the dilemma of donor heart shortage. The ventricular assist device (VAD), as an important category of MCS, demonstrates promising applications in bridging heart transplantation, destination therapy, and bridge-to-decision. VADs can be categorized as durable VADs (dVADs) and temporary VADs (tVADs), according to the duration of assistance. With the technological advancement and clinical application experience accumulated, VADs have been developed in biocompatible, lightweight, bionic, and intelligent ways. In this review, we summarize the development history of VADs, focusing on the mechanism and application status of dVADs in detail, and further discuss the research progress and use of VADs in China.
Collapse
Affiliation(s)
- Jingrong Tu
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Ave, Wuhan 430022, China; (J.T.); (L.X.)
| | - Li Xu
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Ave, Wuhan 430022, China; (J.T.); (L.X.)
| | - Fei Li
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Ave, Wuhan 430022, China; (J.T.); (L.X.)
- Fuwai Yunnan Cardiovascular Hospital, Kunming Medical University, 528 Shahebei Rd, Kunming 650500, China
| | - Nianguo Dong
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Ave, Wuhan 430022, China; (J.T.); (L.X.)
| |
Collapse
|
4
|
Davies J, Thai MT, Low H, Phan PT, Hoang TT, Lovell NH, Do TN. Bio-SHARPE: Bioinspired Soft and High Aspect Ratio Pumping Element for Robotic and Medical Applications. Soft Robot 2023; 10:1055-1069. [PMID: 37130309 DOI: 10.1089/soro.2021.0154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023] Open
Abstract
The advent of soft robots has solved many issues posed by their rigid counterparts, including safer interactions with humans and the capability to work in narrow and complex environments. While much work has been devoted to developing soft actuators and bioinspired mechatronic systems, comparatively little has been done to improve the methods of actuation. Hydraulically soft actuators (HSAs) are emerging candidates to control soft robots due to their fast responses, low noise, and low hysteresis compared to compressible pneumatic ones. Despite advances, current hydraulic sources for large HSAs are still bulky and require high power availability to drive the pumping plant. To overcome these challenges, this work presents a new bioinspired soft and high aspect ratio pumping element (Bio-SHARPE) for use in soft robotic and medical applications. This new soft pumping element can amplify its input volume to at least 8.6 times with a peak pressure of at least 40 kPa. The element can be integrated into existing hydraulic pumping systems like a hydraulic gearbox. Naturally, an amplification of fluid volume can only come at the sacrifice of pumping pressure, which was observed as a 19.1:1 reduction from input to output pressure. The new concept enables a large soft robotic body to be actuated by smaller fluid reservoirs and pumping plant, potentially reducing their power and weight, and thus facilitating drive source miniaturization. The high amplification ratio also makes soft robotic systems more applicable for human-centric applications such as rehabilitation aids, bioinspired untethered soft robots, medical devices, and soft artificial organs. Details of the fabrication and experimental characterization of the Bio-SHARPE and its associated components are given. A soft robotic squid and an artificial heart ventricle are introduced and experimentally validated.
Collapse
Affiliation(s)
- James Davies
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Mai Thanh Thai
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Harrison Low
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Phuoc Thien Phan
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Trung Thien Hoang
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Nigel Hamilton Lovell
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Thanh Nho Do
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
5
|
Weymann A, Foroughi J, Vardanyan R, Punjabi PP, Schmack B, Aloko S, Spinks GM, Wang CH, Arjomandi Rad A, Ruhparwar A. Artificial Muscles and Soft Robotic Devices for Treatment of End-Stage Heart Failure. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2207390. [PMID: 36269015 DOI: 10.1002/adma.202207390] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 09/19/2022] [Indexed: 05/12/2023]
Abstract
Medical soft robotics constitutes a rapidly developing field in the treatment of cardiovascular diseases, with a promising future for millions of patients suffering from heart failure worldwide. Herein, the present state and future direction of artificial muscle-based soft robotic biomedical devices in supporting the inotropic function of the heart are reviewed, focusing on the emerging electrothermally artificial heart muscles (AHMs). Artificial muscle powered soft robotic devices can mimic the action of complex biological systems such as heart compression and twisting. These artificial muscles possess the ability to undergo complex deformations, aiding cardiac function while maintaining a limited weight and use of space. Two very promising candidates for artificial muscles are electrothermally actuated AHMs and biohybrid actuators using living cells or tissue embedded with artificial structures. Electrothermally actuated AHMs have demonstrated superior force generation while creating the prospect for fully soft robotic actuated ventricular assist devices. This review will critically analyze the limitations of currently available devices and discuss opportunities and directions for future research. Last, the properties of the cardiac muscle are reviewed and compared with those of different materials suitable for mechanical cardiac compression.
Collapse
Affiliation(s)
- Alexander Weymann
- Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center, University of Duisburg-Essen, Hufelandstraße 55, 45122, Essen, Germany
| | - Javad Foroughi
- Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center, University of Duisburg-Essen, Hufelandstraße 55, 45122, Essen, Germany
- Faculty of Engineering and Information Sciences, University of Wollongong, Northfields Ave, Wollongong, NSW, 2522, Australia
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Library Rd, Kensington, NSW, 2052, Australia
| | - Robert Vardanyan
- Department of Medicine, Faculty of Medicine, Imperial College London, Imperial College Road, London, SW7 2AZ, UK
| | - Prakash P Punjabi
- Department of Cardiothoracic Surgery, Hammersmith Hospital, National Heart and Lung Institute, Imperial College London, 72 Du Cane Rd, London, W12 0HS, UK
| | - Bastian Schmack
- Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center, University of Duisburg-Essen, Hufelandstraße 55, 45122, Essen, Germany
| | - Sinmisola Aloko
- Faculty of Engineering and Information Sciences, University of Wollongong, Northfields Ave, Wollongong, NSW, 2522, Australia
| | - Geoffrey M Spinks
- Faculty of Engineering and Information Sciences, University of Wollongong, Northfields Ave, Wollongong, NSW, 2522, Australia
| | - Chun H Wang
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Library Rd, Kensington, NSW, 2052, Australia
| | - Arian Arjomandi Rad
- Department of Medicine, Faculty of Medicine, Imperial College London, Imperial College Road, London, SW7 2AZ, UK
| | - Arjang Ruhparwar
- Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center, University of Duisburg-Essen, Hufelandstraße 55, 45122, Essen, Germany
| |
Collapse
|
6
|
Martinez T, Jahren SE, Walter A, Chavanne J, Clavica F, Ferrari L, Heinisch PP, Casoni D, Haeberlin A, Luedi MM, Obrist D, Carrel T, Civet Y, Perriard Y. A novel soft cardiac assist device based on a dielectric elastomer augmented aorta: An in vivo study. Bioeng Transl Med 2023; 8:e10396. [PMID: 36925677 PMCID: PMC10013878 DOI: 10.1002/btm2.10396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 07/12/2022] [Accepted: 08/08/2022] [Indexed: 11/05/2022] Open
Abstract
Although heart transplant is the preferred solution for patients suffering from heart failures, cardiac assist devices remain key substitute therapies. Among them, aortic augmentation using dielectric elastomer actuators (DEAs) might be an alternative technological application for the future. The electrically driven actuator does not require bulky pneumatic elements (such as conventional intra-aortic balloon pumps) and conforms tightly to the aorta thanks to the manufacturing method presented here. In this study, the proposed DEA-based device replaces a section of the aorta and acts as a counterpulsation device. The feasibility and validation of in vivo implantation of the device into the descending aorta in a porcine model, and the level of support provided to the heart are investigated. Additionally, the influence of the activation profile and delay compared to the start of systole is studied. We demonstrate that an activation of the DEA just before the start of systole (30 ms at 100 bpm) and deactivation just after the start of diastole (0-30 ms) leads to an optimal assistance of the heart with a maximum energy provided by the DEA. The end-diastolic and left ventricular pressures were lowered by up to 5% and 1%, respectively, compared to baseline. The early diastolic pressure was augmented in average by up to 2%.
Collapse
Affiliation(s)
- Thomas Martinez
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland
| | - Silje Ekroll Jahren
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland.,ARTORG Center for Biomedical Engineering Research University of Bern Bern Switzerland
| | - Armando Walter
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland
| | - Jonathan Chavanne
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland
| | - Francesco Clavica
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland.,ARTORG Center for Biomedical Engineering Research University of Bern Bern Switzerland
| | - Lorenzo Ferrari
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland.,ARTORG Center for Biomedical Engineering Research University of Bern Bern Switzerland
| | - Paul Philipp Heinisch
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich Technical University of Munich Munich Germany.,Division of Congenital and Pediatric Heart Surgery University Hospital of Munich, Ludwig-Maximilians-University Munich Germany
| | - Daniela Casoni
- Experimental Surgery Facility University of Bern Bern Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Bern University Hospital Inselspital University of Bern Bern Switzerland
| | - Markus M Luedi
- Department of Anaesthesiology, Bern University Hospital Inselspital University of Bern Bern Switzerland
| | - Dominik Obrist
- ARTORG Center for Biomedical Engineering Research University of Bern Bern Switzerland
| | - Thierry Carrel
- Department of Cardiac Surgery University of Zurich Zurich Switzerland
| | - Yoan Civet
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland
| | - Yves Perriard
- Integrated Actuators Laboratory (LAI), École polytechnique fédérale de Lausanne (EPFL) Neuchâtel Switzerland
| |
Collapse
|
7
|
Hu L, Bonnemain J, Saeed MY, Singh M, Quevedo Moreno D, Vasilyev NV, Roche ET. An implantable soft robotic ventilator augments inspiration in a pig model of respiratory insufficiency. Nat Biomed Eng 2023; 7:110-123. [PMID: 36509912 PMCID: PMC9991903 DOI: 10.1038/s41551-022-00971-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 10/26/2022] [Indexed: 12/14/2022]
Abstract
Severe diaphragm dysfunction can lead to respiratory failure and to the need for permanent mechanical ventilation. Yet permanent tethering to a mechanical ventilator through the mouth or via tracheostomy can hinder a patient's speech, swallowing ability and mobility. Here we show, in a porcine model of varied respiratory insufficiency, that a contractile soft robotic actuator implanted above the diaphragm augments its motion during inspiration. Synchronized actuation of the diaphragm-assist implant with the native respiratory effort increased tidal volumes and maintained ventilation flow rates within the normal range. Robotic implants that intervene at the diaphragm rather than at the upper airway and that augment physiological metrics of ventilation may restore respiratory performance without sacrificing quality of life.
Collapse
Affiliation(s)
- Lucy Hu
- Harvard-MIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jean Bonnemain
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
- Department of Adult Intensive Care Medicine, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Mossab Y Saeed
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Manisha Singh
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Diego Quevedo Moreno
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Nikolay V Vasilyev
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Ellen T Roche
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
8
|
Karim ML, Bosnjak AM, McLaughlin J, Crawford P, McEneaney D, Escalona OJ. Transcutaneous Pulsed RF Energy Transfer Mitigates Tissue Heating in High Power Demand Implanted Device Applications: In Vivo and In Silico Models Results. SENSORS (BASEL, SWITZERLAND) 2022; 22:7775. [PMID: 36298125 PMCID: PMC9611940 DOI: 10.3390/s22207775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/29/2022] [Accepted: 10/08/2022] [Indexed: 06/16/2023]
Abstract
This article presents the development of a power loss emulation (PLE) system device to study and find ways of mitigating skin tissue heating effects in transcutaneous energy transmission systems (TETS) for existing and next generation left ventricular assist devices (LVADs). Skin thermal profile measurements were made using the PLE system prototype and also separately with a TETS in a porcine model. Subsequent data analysis and separate computer modelling studies permit understanding of the contribution of tissue blood perfusion towards cooling of the subcutaneous tissue around the electromagnetic coupling area. A 2-channel PLE system prototype and a 2-channel TETS prototype were implemented for this study. The heating effects resulting from power transmission inefficiency were investigated under varying conditions of power delivery levels for an implanted device. In the part of the study using the PLE setup, the implanted heating element was placed subcutaneously 6-8 mm below the body surface of in vivo porcine model skin. Two operating modes of transmission coupling power losses were emulated: (a) conventional continuous transmission, and (b) using our proposed pulsed transmission waveform protocols. Experimental skin tissue thermal profiles were studied for various levels of LVAD power. The heating coefficient was estimated from the porcine model measurements (an in vivo living model and a euthanised cadaver model without blood circulation at the end of the experiment). An in silico model to support data interpretation provided reliable experimental and numerical methods for effective wireless transdermal LVAD energization advanced solutions. In the separate second part of the study conducted with a separate set of pigs, a two-channel inductively coupled RF driving system implemented wireless power transfer (WPT) to a resistive LVAD model (50 Ω) to explore continuous versus pulsed RF transmission modes. The RF-transmission pulse duration ranged from 30 ms to 480 ms, and the idle time (no-transmission) from 5 s to 120 s. The results revealed that blood perfusion plays an important cooling role in reducing thermal tissue damage from TETS applications. In addition, the results analysis of the in vivo, cadaver (R1Sp2) model, and in silico studies confirmed that the tissue heating effect was significantly lower in the living model versus the cadaver model due to the presence of blood perfusion cooling effects.
Collapse
Affiliation(s)
- Mohammad L. Karim
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - Antonio M. Bosnjak
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - James McLaughlin
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - Paul Crawford
- Paul Crawford Veterinary Services, Larne BT40 3RW, UK
| | - David McEneaney
- Cardiovascular Research Unit, Craigavon Area Hospital, Portadown, Craigavon BT63 5QQ, UK
| | - Omar J. Escalona
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| |
Collapse
|
9
|
Cormican DS, Madden C, Rodrigue MF. Mechanical circulatory support: complications, outcomes, and future directions. Int Anesthesiol Clin 2022; 60:72-80. [PMID: 35960687 DOI: 10.1097/aia.0000000000000373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Daniel S Cormican
- Cardiothoracic & Transplant Anesthesiology and Surgical Critical Care, Anesthesiology Institute, Allegheny Health Network, Pittsburgh, Pennsylvania
| | - Claire Madden
- Surgical Critical Care, Surgery Institute, Allegheny Health Network, Pittsburgh, Pennsylvania
| | - Marc F Rodrigue
- Cardiothoracic Anesthesiology, Anesthesiology Institute, Allegheny Health Network, Pittsburgh, Pennsylvania
| |
Collapse
|
10
|
Martonová D, Holz D, Brackenhammer D, Weyand M, Leyendecker S, Alkassar M. Support Pressure Acting on the Epicardial Surface of a Rat Left Ventricle—A Computational Study. Front Cardiovasc Med 2022; 9:850274. [PMID: 35872914 PMCID: PMC9299250 DOI: 10.3389/fcvm.2022.850274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 05/31/2022] [Indexed: 11/13/2022] Open
Abstract
The present computational study investigates the effects of an epicardial support pressure mimicking a heart support system without direct blood contact. We chose restrictive cardiomyopathy as a model for a diseased heart. By changing one parameter representing the amount of fibrosis, this model allows us to investigate the impairment in a diseased left ventricle, both during diastole and systole. The aim of the study is to determine the temporal course and value of the support pressure that leads to a normalization of the cardiac parameters in diseased hearts. These are quantified via the end-diastolic pressure, end-diastolic volume, end-systolic volume, and ejection fraction. First, the amount of fibrosis is increased to model diseased hearts at different stages. Second, we determine the difference in the left ventricular pressure between a healthy and diseased heart during a cardiac cycle and apply for the epicardial support as the respective pressure difference. Third, an epicardial support pressure is applied in form of a piecewise constant step function. The support is provided only during diastole, only during systole, or during both phases. Finally, the support pressure is adjusted to reach the corresponding parameters in a healthy rat. Parameter normalization is not possible to achieve with solely diastolic or solely systolic support; for the modeled case with 50% fibrosis, the ejection fraction can be increased by 5% with purely diastolic support and 14% with purely systolic support. However, the ejection fraction reaches the value of the modeled healthy left ventricle (65.6%) using a combination of diastolic and systolic support. The end-diastolic pressure of 13.5 mmHg cannot be decreased with purely systolic support. However, the end-diastolic pressure reaches the value of the modeled healthy left ventricle (7.5 mmHg) with diastolic support as well as with the combination of the diastolic and systolic support. The resulting negative diastolic support pressure is −4.5 mmHg, and the positive systolic support pressure is 90 mmHg. We, thereby, conclude that ventricular support during both diastole and systole is beneficial for normalizing the left ventricular ejection fraction and the end-diastolic pressure, and thus it is a potentially interesting therapy for cardiac insufficiency.
Collapse
Affiliation(s)
- Denisa Martonová
- Institute of Applied Dynamics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- *Correspondence: Denisa Martonová
| | - David Holz
- Institute of Applied Dynamics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Dorothea Brackenhammer
- Institute of Applied Dynamics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Michael Weyand
- Department of Cardiac Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sigrid Leyendecker
- Institute of Applied Dynamics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Muhannad Alkassar
- Department of Cardiac Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
11
|
Concept, Design, and Early Prototyping of a Low-Cost, Minimally Invasive, Fully Implantable Left Ventricular Assist Device. Bioengineering (Basel) 2022; 9:bioengineering9050201. [PMID: 35621479 PMCID: PMC9137825 DOI: 10.3390/bioengineering9050201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 04/28/2022] [Accepted: 05/04/2022] [Indexed: 11/23/2022] Open
Abstract
Despite evidence associating the use of mechanical circulatory support (MCS) devices with increased survival and quality of life in patients with advanced heart failure (HF), significant complications and high costs limit their clinical use. We aimed to design an innovative MCS device to address three important needs: low cost, minimally invasive implantation techniques, and low risk of infection. We used mathematical modeling to calculate the pump characteristics to deliver variable flows at different pump diameters, turbomachinery design software CFturbo (2020 R2.4 CFturbo GmbH, Dresden, Germany) to create the conceptual design of the pump, computational fluid dynamics analysis with Solidworks Flow Simulation to in silico test pump performance, Solidworks (Dassault Systèmes SolidWorks Corporation, Waltham, MA, USA) to further refine the design, 3D printing with polycarbonate filament for the initial prototype, and a stereolithography printer (Form 2, Formlabs, Somerville, MA, USA) for the second variant materialization. We present the concept, design, and early prototyping of a low-cost, minimally invasive, fully implantable in a subcutaneous pocket MCS device for long-term use and partial support in patients with advanced HF which unloads the left heart into the arterial system containing a rim-driven, hubless axial-flow pump and the wireless transmission of energy. We describe a low-cost, fully implantable, low-invasive, wireless power transmission left ventricular assist device that has the potential to address patients with advanced HF with higher impact, especially in developing countries. In vitro testing will provide input for further optimization of the device before proceeding to a completely functional prototype that can be implanted in animals.
Collapse
|
12
|
Bonnemain J, Del Nido PJ, Roche ET. Direct Cardiac Compression Devices to Augment Heart Biomechanics and Function. Annu Rev Biomed Eng 2022; 24:137-156. [PMID: 35395165 DOI: 10.1146/annurev-bioeng-110220-025309] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The treatment of end-stage heart failure has evolved substantially with advances in medical treatment, cardiac transplantation, and mechanical circulatory support (MCS) devices such as left ventricular assist devices and total artificial hearts. However, current MCS devices are inherently blood contacting and can lead to potential complications including pump thrombosis, hemorrhage, stroke, and hemolysis. Attempts to address these issues and avoid blood contact led to the concept of compressing the failing heart from the epicardial surface and the design of direct cardiac compression (DCC) devices. We review the fundamental concepts related to DCC, present the foundational devices and recent devices in the research and commercialization stages, and discuss the milestones required for clinical translation and adoption of this technology. Expected final online publication date for the Annual Review of Biomedical Engineering, Volume 24 is June 2022. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.
Collapse
Affiliation(s)
- Jean Bonnemain
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Department of Adult Intensive Care Medicine, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland;
| | - Pedro J Del Nido
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts, USA;
| | - Ellen T Roche
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Department of Mechanical Engineering and Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA;
| |
Collapse
|
13
|
Hydrodynamic Bearing Structural Design of Blood Pump Based on Axial Passive Suspension Stability Analysis of Magnetic–Hydrodynamic Hybrid Suspension System. MACHINES 2021. [DOI: 10.3390/machines9110255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Rotor suspension stability is one of the important performance indexes of a blood pump and the basis of determining whether the blood pump can be used in a clinic. Compared with the traditional magnetic suspension system, a single-winding, bearingless motor has the advantages of a compact structure, simple control system and low power consumption. In this pursuit, the present study aimed to envisage and design the magnetic suspension system coupled with a single-winding bearingless motor and permanent magnet bearings, establish the theoretical models of axial force and electromagnetic torque, and calculate the stiffness of the magnetic suspension system at the equilibrium point. Addressing the problem of the negative axial stiffness of the magnetic suspension system being negative, which leads to the instability of the suspension rotor, the hydrodynamic bearing structure was proposed and designed, and the critical stiffness to realize the stable suspension of the rotor was obtained based on the stability criterion of the rotor dynamics model. The optimal structural parameters of the hydrodynamic bearing are selected by integrating various factors based on the solution of the Reynolds equation and a stiffness analysis. Furthermore, the vibration experiment results proved that the blood pump rotor exhibited a good suspension stability, and the maximum offset under the impact external fluid was no more than 2 μm.
Collapse
|
14
|
Ramaswamy RK, Marimuthu SK, Ramarathnam KK, Vijayasekharan S, Rao KGS, Balakrishnan KR. Virtual reality-guided left ventricular assist device implantation in pediatric patient: Valuable presurgical tool. Ann Pediatr Cardiol 2021; 14:388-392. [PMID: 34667413 PMCID: PMC8457285 DOI: 10.4103/apc.apc_81_21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 12/03/2022] Open
Abstract
Virtual reality (VR) is increasingly used for presurgical planning and teaching during surgery. However, VR aided presurgical planning toolbox for left ventricular assist device (LVAD) implantation is not widely available. We investigated the use of a VR environment with wearable headsets and touch controllers in simulating an implant in an 11-year-old boy. The technology played a significant role in the optimal positioning of the LVAD.
Collapse
Affiliation(s)
| | - Sathish Kumar Marimuthu
- Department of Engineering Design, Indian Institute of Technology, Chennai, Tamil Nadu, India
| | | | - Srinath Vijayasekharan
- Department of Heart and Lung Transplant/Mechanical Circulatory Support, Institute of Heart and Lung Transplant, MGM Health Care, Chennai, Tamil Nadu, India
| | - Kemundel Genny Suresh Rao
- Department of Heart and Lung Transplant/Mechanical Circulatory Support, Institute of Heart and Lung Transplant, MGM Health Care, Chennai, Tamil Nadu, India
| | - Komarakshi R Balakrishnan
- Department of Heart and Lung Transplant/Mechanical Circulatory Support, Institute of Heart and Lung Transplant, MGM Health Care, Chennai, Tamil Nadu, India
| |
Collapse
|
15
|
Ferrari G, Di Molfetta A, Zieliński K, Cusimano V, Darowski M, Kozarski M, Fresiello L. Assessment of the VAD – Native ventricle pumping system by an equivalent pump: A computational model based procedure. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
An Intra-Cycle Optimal Control Framework for Ventricular Assist Devices Based on Atrioventricular Plane Displacement Modeling. Ann Biomed Eng 2021; 49:3508-3523. [PMID: 34549343 PMCID: PMC8671277 DOI: 10.1007/s10439-021-02848-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 08/04/2021] [Indexed: 12/04/2022]
Abstract
A promising treatment for congestive heart failure is the implementation of a left ventricular assist device (LVAD) that works as a mechanical pump. Modern LVADs work with adjustable constant rotor speed and provide therefore continuous blood flow; however, recently undertaken efforts try to mimic pulsatile blood flow by oscillating the pump speed. This work proposes an algorithmic framework to construct and evaluate optimal pump speed policies with respect to generic objectives. We use a model that captures the atrioventricular plane displacement, which is a physiological indicator for heart failure. We employ mathematical optimization to adapt this model to patient specific data and to find optimal pump speed policies with respect to ventricular unloading and aortic valve opening. To this end, we reformulate the cardiovascular dynamics into a switched system and thereby reduce nonlinearities. We consider system switches that stem from varying the constant pump speed and that are state dependent such as valve opening or closing. As a proof of concept study, we personalize the model to a selected patient with respect to ventricular pressure. The model fitting results in a root-mean-square deviation of about 6 mmHg. The optimization that considers aortic valve opening and ventricular unloading results in speed modulation akin to counterpulsation. These in silico findings demonstrate the potential of personalized hemodynamical optimization for the LVAD therapy.
Collapse
|
17
|
Masterson Creber R, Spadaccio C, Dimagli A, Myers A, Taylor B, Fremes S. Patient-Reported Outcomes in Cardiovascular Trials. Can J Cardiol 2021; 37:1340-1352. [PMID: 33974992 PMCID: PMC8487900 DOI: 10.1016/j.cjca.2021.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 03/31/2021] [Accepted: 04/11/2021] [Indexed: 12/25/2022] Open
Abstract
Patient-reported outcomes (PROs) are reports of a person's health status that provide a global perspective of patient well-being. PROs can be classified into 4 primary domains: global, mental, physical, and social health. In this descriptive review, we focus on how PROs can be used in cardiac clinical trials, with an emphasis on cardiac surgical trials for patients with coronary heart disease and heart failure. We also highlight ongoing challenges and provide specific suggestions and novel opportunities to advance cardiac clinical trials. Current challenges include the long-term measurement of PROs in clinical trials beyond 1 year, inconsistency in the choice of the outcome measures among studies, and the lack of measurement of PROs across multiple domains. Opportunities for advancement include measuring PROs using consumer health informatics tools, including returning information back to participants in formats that they can understand using visualization. Future opportunities include quantifying cohort-specific minimal clinically important differences for PROs.
Collapse
Affiliation(s)
- Ruth Masterson Creber
- Department of Population Health Sciences, Weill Cornell Medicine, New York, New York, USA.
| | - Cristiano Spadaccio
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Arnaldo Dimagli
- Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Annie Myers
- Department of Population Health Sciences, Weill Cornell Medicine, New York, New York, USA
| | - Brittany Taylor
- School of Nursing, Columbia University, New York, New York, USA
| | - Stephen Fremes
- Sunnybrook Health Science, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
18
|
Germena G, Hinkel R. iPSCs and Exosomes: Partners in Crime Fighting Cardiovascular Diseases. J Pers Med 2021; 11:jpm11060529. [PMID: 34207562 PMCID: PMC8230331 DOI: 10.3390/jpm11060529] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 05/31/2021] [Accepted: 06/07/2021] [Indexed: 12/17/2022] Open
Abstract
Cardiovascular diseases are the leading cause of mortality worldwide. Understanding the mechanisms at the basis of these diseases is necessary in order to generate therapeutic approaches. Recently, cardiac tissue engineering and induced pluripotent stem cell (iPSC) reprogramming has led to a skyrocketing number of publications describing cardiovascular regeneration as a promising option for cardiovascular disease treatment. Generation of artificial tissue and organoids derived from induced pluripotent stem cells is in the pipeline for regenerative medicine. The present review summarizes the multiple approaches of heart regeneration with a special focus on iPSC application. In particular, we describe the strength of iPSCs as a tool to study the molecular mechanisms driving cardiovascular pathologies, as well as their potential in drug discovery. Moreover, we will describe some insights into novel discoveries of how stem-cell-secreted biomolecules, such as exosomes, could affect cardiac regeneration, and how the fine tuning of the immune system could be a revolutionary tool in the modulation of heart regeneration.
Collapse
Affiliation(s)
- Giulia Germena
- Laboratory Animal Science Unit, Leibniz-Institut für Primatenforschung, Deutsches Primatenzentrum GmbH, Kellnerweg 4, 37077 Göttingen, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, 37077 Göttingen, Germany
- Correspondence: (G.G.); (R.H.)
| | - Rabea Hinkel
- Laboratory Animal Science Unit, Leibniz-Institut für Primatenforschung, Deutsches Primatenzentrum GmbH, Kellnerweg 4, 37077 Göttingen, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, 37077 Göttingen, Germany
- Stiftung Tierärztliche Hochschule Hannover, University of Veterinary Medicine, 30559 Hannover, Germany
- Correspondence: (G.G.); (R.H.)
| |
Collapse
|
19
|
Coil Design of a Wireless Power-Transfer Receiver Integrated into a Left Ventricular Assist Device. ELECTRONICS 2021. [DOI: 10.3390/electronics10080874] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
This study deals with the design of a near-field wireless power transfer (WPT) system applied to a left ventricular assist device (LVAD) to treat patients with heart-failure problems. An LVAD is an implanted electrically driven pump connected to the heart and is traditionally powered by batteries external to the human body via a percutaneous driveline cable. The main challenge of wirelessly powering an LVAD implanted deep in the human body is to transfer relatively high power with high efficiency levels. Here the optimal design of the primary and secondary WPT coils is proposed to improve the performance of the WPT, avoiding possible safety problems of electromagnetic fields (EMF). As a main result, an average power of 5 W is continuously delivered to the LVAD by the WPT system working at 6.78 MHz with a total (DC–to–DC) efficiency of approximately 65% for the worst-case configuration.
Collapse
|
20
|
Checchia PA, Brown KL, Wernovsky G, Penny DJ, Bronicki RA. The Evolution of Pediatric Cardiac Critical Care. Crit Care Med 2021; 49:545-557. [PMID: 33591011 DOI: 10.1097/ccm.0000000000004832] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Paul A Checchia
- Section of Critical Care Medicine, Department of Pediatrics, Baylor College of Medicine, Texas Children's Hospital, Houston, TX
| | - Katherine L Brown
- Heart and Lung Division and Biomedical Research Centre, Great Ormond Street Hospital NHS Foundation Trust, London, United Kingdom
- Institute of Cardiovascular Science, University College London, London, United Kingdom
| | - Gil Wernovsky
- Cardiac Critical Care and Pediatric Cardiology, Children's National Medical Center and George Washington University School of Medicine and Health Sciences, Washington DC
| | - Daniel J Penny
- Section of Cardiology, Department of Pediatrics, Baylor College of Medicine and Texas Children's Hospital, Houston TX
| | - Ronald A Bronicki
- Section of Critical Care Medicine, Department of Pediatrics, Baylor College of Medicine, Texas Children's Hospital, Houston, TX
| |
Collapse
|
21
|
Jefferson HL, Kent WDT, MacQueen KT, Miller RJH, Holloway DD, Fatehi Hassanabad A. Left ventricular assist devices: A comprehensive review of major clinical trials, devices, and future directions. J Card Surg 2021; 36:1480-1491. [PMID: 33476443 DOI: 10.1111/jocs.15341] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 01/02/2021] [Accepted: 01/04/2021] [Indexed: 11/30/2022]
Abstract
Heart failure is an increasingly prevalent medical condition associated with significant morbidity and mortality. In spite of optimal medical therapy, a large number of patients continue to deteriorate clinically and could potentially benefit from advanced therapies. While cardiac transplantation is an established therapy for end-stage heart failure, there are a limited number of donor hearts, and many patients may not be candidates. Over the past two decades, mechanical circulatory support and left ventricular assist devices (LVAD) have altered the heart failure management landscape. Herein we review the indications for LVAD implantation and how they have changed over time. We will also outline major technological evolutions in LVADs and summarize the landmark clinical trials pertaining to them. We also highlight the adverse events associated with LVADs and assess the limitations of the existing literature. Finally, we look ahead to the future of LVAD therapy for patients with advanced heart failure.
Collapse
Affiliation(s)
- Hallie L Jefferson
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, Calgary, Alberta, Canada
| | - William D T Kent
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, Calgary, Alberta, Canada
| | - Kelsey T MacQueen
- Faculty of Medicine, Cumming School of Medicine, Calgary, Alberta, Canada
| | - Robert J H Miller
- Section of Cardiology, Department of Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, Calgary, Alberta, Canada
| | - Daniel D Holloway
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, Calgary, Alberta, Canada
| | - Ali Fatehi Hassanabad
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, Cumming School of Medicine, Calgary, Alberta, Canada
| |
Collapse
|
22
|
Kuśmierczyk M, Różański J, Zembala M, Dudek D, Braksator W, Grodzicki T, Hoffman P, Sadowski J, Gruchała M, Legutko J, Siondalski P, Wierzbicki K, Kapelak B, Opolski G, Juraszek A, Bondaryk K, Walczak J, Pieniążek I, Grys M, Przygodzki P. Heart failure in Poland: Left ventricular assist device destination therapy and other challenges of interventional cardiology and cardiac surgery. Cardiol J 2020; 27:693-704. [PMID: 33140383 DOI: 10.5603/cj.a2020.0148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 10/12/2020] [Indexed: 11/25/2022] Open
Abstract
Patients with severe heart failure (HF), who are not eligible for cardiac transplantation and receive optimal medical management, based mainly on the use of pharmacological treatment and devices such as resynchronization therapy (implantable cardioverter-defibrillator), achieve poor clinical outcomes and constitute a group with extremely poor prognosis. Currently, the technology used in the latest generation left ventricular assist devices (LVADs), such as the HeartMate 3, makes it possible to achieve patient survival at the level obtained by patients after heart transplantation, and they can be used not only in patients eligible for heart transplantation as a bridge to transplant, but also in those with significantly worse prognosis, who are ineligible for heart transplantation as destination therapy. The objective of this publication is to present recommendations from experts in cardiology and cardiac surgery, supported by clinical trial results, on the use of LVADs as a destination therapy in HF patients who are not eligible for cardiac transplantation. The paper also presents the issue of cardiac transplantation and extracorporeal membrane oxygenation therapy in Poland, as well as current challenges faced by interventional cardiology and cardiac surgery in Poland.
Collapse
Affiliation(s)
- Mariusz Kuśmierczyk
- Department of Cardiac Surgery and Transplantology, National Institute of Cardiology, Warsaw, Poland
| | - Jacek Różański
- Department of Cardiac Surgery and Transplantology, National Institute of Cardiology, Warsaw, Poland
| | - Michał Zembala
- Department of Cardiac Surgery Heart and Lung Transplantation and Mechanical Circulatory Support Silesian Center For Heart Diseases, Zabrze, Poland
| | - Dariusz Dudek
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.,Maria Cecilia Hospital, GVM Care&Research, Cotignola (RA), Ravenna, Italy
| | - Wojciech Braksator
- Department of Sports Cardiology and Non-invasive Cardiac Imaging, 2nd Medical Faculty, Medical University of Warsaw, Warsaw, Poland
| | - Tomasz Grodzicki
- Department of Internal Medicine and Gerontology, Medical College, Jagiellonian University, Krakow, Poland
| | - Piotr Hoffman
- Department of Congenital Heart Disease, National Institute of Cardiology, Warsaw, Poland
| | - Jerzy Sadowski
- Department of Cardiovascular Surgery and Transplantology, The John Paul II Hospital, Krakow, Poland, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
| | - Marcin Gruchała
- 1st Department of Cardiology, Medical University of Gdansk, Gdansk, Poland
| | - Jacek Legutko
- Jagiellonian University Medical College, Faculty of Medicine, Institute of Cardiology, Department of Interventional Cardiology, The John Paul II Hospital, Krakow, Poland
| | - Piotr Siondalski
- Cardiac and Vascular Surgery Department, Medical University of Gdansk, Gdansk, Poland
| | - Karol Wierzbicki
- Department of Cardiovascular Surgery and Transplantology, The John Paul II Hospital, Krakow, Poland, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
| | - Bogusław Kapelak
- Department of Cardiovascular Surgery and Transplantology, The John Paul II Hospital, Krakow, Poland, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
| | - Grzegorz Opolski
- 1st Chair and Department of Cardiology Medical University of Warsaw, Warsaw, Poland
| | - Andrzej Juraszek
- Department of Cardiac Surgery and Transplantology, National Institute of Cardiology, Warsaw, Poland
| | | | | | | | - Maciej Grys
- Arcana Institute a Certara Company, Krakow, Poland
| | | |
Collapse
|
23
|
Asuka E, Pak S, Thiess AK, Torres A. Gastrointestinal Bleeding as a Complication in Continuous Flow Ventricular Assist Devices: A Systematic Review With Meta-Analysis. J Clin Med Res 2020; 12:543-559. [PMID: 32849943 PMCID: PMC7430922 DOI: 10.14740/jocmr4262] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 06/26/2020] [Indexed: 12/24/2022] Open
Abstract
Background The use of ventricular assist devices (VADs) has become predominant in this era of medicine. It is commonly used as a bridge to transplant, recovery and as a destination therapy for patients with severe heart failure, who are not responsive to maximum optimal management or ineligible for transplant. However, several complications are known to occur with the use of these devices. In this research, we will compare gastrointestinal bleeding in patients who used centrifugal flow versus axial flow VADs. We hope that the result of this meta-analysis and the review presented provide adequate information to future researchers, physicians and other healthcare professionals who are interested in this topic. Methods Published articles evaluated for inclusion were obtained from MEDLINE (PubMed), Cochrane, EBSCO, clinicaltrials.gov, and international clinical trials registry. This research was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Procured articles were reviewed by two independent reviewers. Only randomized control trials and observational studies were used. Quality assessment was done with Cochrane Collaboration’s tool (RoB.2 with visualization through robviz) and Newcastle-Ottawa Scale (NOS). Data analysis was carried out with the use of R data analysis tool (version 4.0.0; release date: April 24th, 2020). Results At the end of this meta-analysis, the occurrence of gastrointestinal bleeding was not significantly different between both groups; with odds ratio (OR): 0.81; 95% confidence interval (CI): 0.65 - 1.00; P value = 0.05. Between-study variance (Tau-squared) was zero (0), standard error (SE) = 0.06. The degree of heterogeneity measured with I-squared statistic was 0% (minimal). Egger’s regression test was not statistically significant, P = 0.93. Symmetry of distribution was observed on the funnel plot. Trim and fill analysis showed no missing studies on the left; SE = 1.68. Conclusions The result obtained from this research indicates that the occurrence of gastrointestinal bleeding is not significantly different in both groups of patients, irrespective of the type of continuous flow VAD used. Although, the study sample used in this meta-analysis was limited.
Collapse
Affiliation(s)
- Edinen Asuka
- All Saints University School Of Medicine, Hillsborough St, Roseau, Dominica
| | - Stella Pak
- Department of Medicine, Orange Regional Medical Center, 707 East Main Street, Middletown, NY 10940, USA
| | - Armond-Kristopher Thiess
- Department of Medicine, Universidad Autonoma de Guadalajara, Av. Patria 1201, Lomas del Valle 45129, Zapopan, Mexico
| | - Anthony Torres
- Department of Medicine, Universidad Autonoma de Guadalajara, Av. Patria 1201, Lomas del Valle 45129, Zapopan, Mexico
| |
Collapse
|
24
|
Welches ventrikuläre Assistenzsystem für welchen Patienten? ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2020. [DOI: 10.1007/s00398-020-00375-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Corrà U, Pistono M. Exercise capacity in left ventricular assistance device recipients: exercise tolerance to be fit. J Cardiovasc Med (Hagerstown) 2020; 21:481-482. [PMID: 32487864 DOI: 10.2459/jcm.0000000000000957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Ugo Corrà
- Exercise Pathophysiology Laboratory, Istituti Clinici Scientifici Maugeri, Veruno Institute, Via per Revislate
| | - Massimo Pistono
- Laboratory for the analysis of Cardio-Respiratory Signals, Istituti Clinici Scientifici Maugeri, Veruno Institute, Veruno (NO), Italy
| |
Collapse
|
26
|
Chatterjee A, Mariani S, Hanke JS, Li T, Merzah AS, Wendl R, Haverich A, Schmitto JD, Dogan G. Minimally invasive left ventricular assist device implantation: optimizing device design for this approach. Expert Rev Med Devices 2020; 17:323-330. [PMID: 32118488 DOI: 10.1080/17434440.2020.1735358] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Introduction: The global heart failure (HF) burden is expected to increase due to aging populations, increasing number of end-stage HF patients and adverse lifestyle changes. Mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs) have become a promising treatment option for short-term and long-term circulatory support of end-stage HF patients.Areas covered: Recent developments in MCS technology have been focused on miniaturization leading to the development of minimally invasive surgical procedures for LVAD implantation. This helps overcome possible postoperative complications such as major incisions and poor outcomes due to infections, right heart failure, and bleeding. This article discusses clinical and technological developments in the field of minimally invasive procedures for LVAD implantation.Expert opinion: Most patients might benefit from minimally invasive LVAD implantation performed through a limited left lateral thoracotomy associated with an upper hemisternotomy or a right anterior thoracotomy. The thoracotomy approach can also be considered in case of pump exchange or pump explant. The success of these techniques is mainly based on the optimization of LVAD pump design, inflow cannula insertion, and outflow graft as well as driveline exit sites. The future direction of the LVAD field is likely to include less-invasive approaches and smartificial technologies.
Collapse
Affiliation(s)
- Anamika Chatterjee
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Silvia Mariani
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Jasmin S Hanke
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Tong Li
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Ali Saad Merzah
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Regina Wendl
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Jan D Schmitto
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Günes Dogan
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
27
|
Han J, Aranda-Michel E, Trumble DR. Muscle-Powered Counterpulsation for Untethered, Non-Blood-Contacting Cardiac Support: A Path to Destination Therapy. IEEE Trans Biomed Eng 2020; 67:3035-3047. [PMID: 32086191 DOI: 10.1109/tbme.2020.2974826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Conventional long-term ventricular assist devices continue to be extremely problematic due to infections caused by percutaneous drivelines and thrombotic events associated with the use of blood-contacting surfaces. Here we describe a muscle-powered cardiac assist device that avoids both these problems by using an internal muscle energy converter to drive a non-blood-contacting extra-aortic balloon pump. The technology was developed previously in this lab and operates by converting the contractile energy of the latissimus dorsi muscle into hydraulic power that can be used, in principle, to drive any blood pump amenable to pulsatile actuation. The two main advantages of this implantable power source are that it 1) significantly reduces infection risk by avoiding a constant skin wound, and 2) improves patient quality-of-life by eliminating all external hardware components. The counterpulsatile balloon pumps, which compress the external surface of the ascending aorta during the diastolic phase of the cardiac cycle, offer another critical advantage in the setting of long-term circulatory support in that they increase cardiac output and improve coronary perfusion without touching the blood. The goal of this work is to combine these two technologies into a single circulatory support system that eliminates driveline complications and avoids surface-mediated thromboembolic events, thereby providing a safe, tether-free means to support the failing heart over extended - or even indefinite - periods of time.
Collapse
|
28
|
Gu H, Bertrand T, Boehler Q, Chautems C, Vasilyev NV, Nelson BJ. Magnetically Active Cardiac Patches as an Untethered, Non-Blood Contacting Ventricular Assist Device. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 8:2000726. [PMID: 33437567 PMCID: PMC7788498 DOI: 10.1002/advs.202000726] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/20/2020] [Indexed: 05/03/2023]
Abstract
Patients suffering from heart failure often require circulatory support using ventricular assist devices (VADs). However, most existing VADs provide nonpulsatile flow, involve direct contact between the blood flow and the device's lumen and moving components, and require a driveline to connect to an external power source. These design features often lead to complications such as gastrointestinal bleeding, device thrombosis, and driveline infections. Here, a concept of magnetically active cardiac patches (MACPs) that can potentially function as non-blood contacting, untethered pulsatile VADs inside a magnetic actuationsystem is reported. The MACPs, which are composed of permanent magnets and 3D-printed patches, are attached to the epicardial surfaces, thus avoiding direct contact with the blood flow. They provide powerful actuation assisting native heart pumping inside a magnetic actuation system. In ex vivo experiments on a healthy pig's heart, it is shown that the ventricular ejection fractions are as high as 37% in the left ventricle and 63% in the right ventricle. Non-blood contacting, untethered VADs can eliminate the risk of serious complications associated with existing devices, and provide an alternative solution for myocardial training and therapy for patients with heart failure.
Collapse
Affiliation(s)
- Hongri Gu
- Institute of Robotics and Intelligent SystemsETH ZurichZurichCH‐8092Switzerland
| | - Thibaud Bertrand
- Institute of Robotics and Intelligent SystemsETH ZurichZurichCH‐8092Switzerland
| | - Quentin Boehler
- Institute of Robotics and Intelligent SystemsETH ZurichZurichCH‐8092Switzerland
| | - Christophe Chautems
- Institute of Robotics and Intelligent SystemsETH ZurichZurichCH‐8092Switzerland
| | - Nikolay V. Vasilyev
- Department of Cardiac SurgeryBoston Children's HospitalHarvard Medical SchoolBostonMA02115USA
| | - Bradley J. Nelson
- Institute of Robotics and Intelligent SystemsETH ZurichZurichCH‐8092Switzerland
| |
Collapse
|
29
|
A Prototype Photoplethysmography Electronic Device that Distinguishes Congestive Heart Failure from Healthy Individuals by Applying Natural Time Analysis. ELECTRONICS 2019. [DOI: 10.3390/electronics8111288] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this paper, a prototype photoplethysmography (PPG) electronic device is presented for the distinction of individuals with congestive heart failure (CHF) from the healthy (H) by applying the concept of Natural Time Analysis (NTA). Data were collected simultaneously with a conventional three-electrode electrocardiography (ECG) system and our prototype PPG electronic device from H and CHF volunteers at the 2nd Department of Cardiology, Medical School of Ioannina, Greece. Statistical analysis of the results show a clear separation of CHF from H subjects by means of NTA for both the conventional ECG system and our PPG prototype system, with a clearly better distinction for the second one which additionally inherits the advantages of a low-cost portable device.
Collapse
|
30
|
Gulbulak U, Ertas A. Finite Element Driven Design Domain Identification of a Beating Left Ventricular Simulator. Bioengineering (Basel) 2019; 6:bioengineering6030083. [PMID: 31540196 PMCID: PMC6784146 DOI: 10.3390/bioengineering6030083] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 08/30/2019] [Accepted: 09/10/2019] [Indexed: 11/24/2022] Open
Abstract
Almost ten percent of the American population have heart diseases. Since the number of available heart donors is not promising, left ventricular assist devices are implemented as bridge therapies. Development of the assist devices benefits from both in-vivo animal and in-vitro mock circulation studies. Representation of the heart is a crucial part of the mock circulation setups. Recently, a beating left ventricular simulator with latex rubber and helically oriented McKibben actuators has been proposed. The simulator was able to mimic heart wall motion, however, flow rate was reported to be limited to 2 liters per minute. This study offers a finite element driven design domain identification to identify the combination of wall thickness, number of actuators, and the orientation angle that results in better deformation. A nonlinear finite element model of the simulator was developed and validated. Design domain was constructed with 150 finite element models, each with varying wall thickness and number of actuators with varying orientation angles. Results showed that the combination of 4 mm wall thickness and 8 actuators with 90 degrees orientation performed best in the design domain.
Collapse
Affiliation(s)
- Utku Gulbulak
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Atila Ertas
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| |
Collapse
|
31
|
Ventricle-specific epicardial pressures as a means to optimize direct cardiac compression for circulatory support: A pilot study. PLoS One 2019; 14:e0219162. [PMID: 31276569 PMCID: PMC6611657 DOI: 10.1371/journal.pone.0219162] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 06/17/2019] [Indexed: 01/16/2023] Open
Abstract
Direct cardiac compression (DCC) holds enormous potential as a safe and effective means to treat heart failure patients who require long-term, or even permanent, biventricular support. However, devices developed to date are not tuned to meet the individual compression requirements of the left and right ventricles, which can differ substantially. In this paper, a systematic study examining the relationship, range, and effect of independent pressures on the left and right epicardial surfaces of a passive human heart model was performed as a means to optimize cardiac output via DCC support. Hemodynamic and tissue deformation effects produced by varying epicardial compressions were examined using finite element analysis. Results indicate that 1) designing a direct cardiac compression pump that applies separate pressures to the left and right ventricles is critical to maintain equivalent stroke volume for both ventricles, and 2) left and right ventricular epicardial pressures of 340 mmHg and 44 mmHg, respectively, are required to induce normal ejection fractions in a passive heart. This pilot study provides fundamental insights and guidance towards the design of improved direct cardiac compression devices for long-term circulatory support.
Collapse
|