1
|
Wang S, Li X, Wang X, Wu X, Jiang D, Zhou H, Gao S, Liu J. A triple read-out visible biosensing platform based on multifunctional nanozyme and bipolar electrode for multi-mode detection and imaging of CEA. Biosens Bioelectron 2024; 253:116170. [PMID: 38442619 DOI: 10.1016/j.bios.2024.116170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/01/2024] [Accepted: 02/24/2024] [Indexed: 03/07/2024]
Abstract
In this paper, a proposal of closed bipolar electrode (BPE) and nanozyme based multi-mode biosensing platform is first presented. As a novel integrated chip, multi-mode-BPE (MMBPE) combines enzyme-linked immunoassay (ELISA), electrochemiluminescence (ECL), ECL imaging and light emitting diode (LED) imaging, enabling highly sensitive triple read-out visible detection of cancer embryonic antigen (CEA). The ECL probe Ab2@Au@Co3O4/CoFe2O4 hollow nanocubes (HNCs) with excellent peroxidase (POD) activity is introduced into the BPE cathode through immune adsorption. The Au@Co3O4/CoFe2O4 HNCs can increase the rate of hydrogen peroxide oxidation of TMB, thus promoting the reaction, and can be used for ELISA detection of CEA at different concentrations. The modification of the BPE sensing interface and reporting interface involved the introduction of the luminescent reagent Ru(bpy)32+ to the BPE anode. The decomposition rate of H2O2 increased under the catalytic action of Au@Co3O4/CoFe2O4 HNCs nanozyme, leading to an accelerated electron transfer rate in the MMBPE system and an enhanced ECL signal from Ru(bpy)32+. The LED imaging technology further provides a convenient and visible approach for CEA imaging in which no additional chemicals are needed. The integration of nanoenzymes as the catalytic core in MMBPE system provides impetus, while the combination of nanozymes with BPE expands the application of nanoenzymes in the field of biological analysis. The integration of intelligent chips with multiple modes of detection shows portable, miniaturized, and integrated excellent properties which meets the requirements of modern detection devices and thus offers a flexible approach for determination of nucleic acids, proteins, and cells.
Collapse
Affiliation(s)
- Shumin Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xinyue Li
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xinli Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xiaodi Wu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Degang Jiang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Hong Zhou
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Shunxiang Gao
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200080, PR China.
| | - Jing Liu
- College of Chemical and Biological Engineering, Shandong University of Science and Technology, Qingdao, Shandong, 266590, PR China.
| |
Collapse
|
2
|
Cheng HP, Yang TH, Wang JC, Chuang HS. Recent Trends and Innovations in Bead-Based Biosensors for Cancer Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:2904. [PMID: 38733011 PMCID: PMC11086254 DOI: 10.3390/s24092904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024]
Abstract
Demand is strong for sensitive, reliable, and cost-effective diagnostic tools for cancer detection. Accordingly, bead-based biosensors have emerged in recent years as promising diagnostic platforms based on wide-ranging cancer biomarkers owing to the versatility, high sensitivity, and flexibility to perform the multiplexing of beads. This comprehensive review highlights recent trends and innovations in the development of bead-based biosensors for cancer-biomarker detection. We introduce various types of bead-based biosensors such as optical, electrochemical, and magnetic biosensors, along with their respective advantages and limitations. Moreover, the review summarizes the latest advancements, including fabrication techniques, signal-amplification strategies, and integration with microfluidics and nanotechnology. Additionally, the challenges and future perspectives in the field of bead-based biosensors for cancer-biomarker detection are discussed. Understanding these innovations in bead-based biosensors can greatly contribute to improvements in cancer diagnostics, thereby facilitating early detection and personalized treatments.
Collapse
Affiliation(s)
- Hui-Pin Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
| | - Tai-Hua Yang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Department of Orthopedic Surgery, National Cheng Kung University Hospital, Tainan 704, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| | - Jhih-Cheng Wang
- Department of Urology, Chimei Medical Center, Tainan 710, Taiwan
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan 710, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung 804, Taiwan
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
3
|
Abbasi R, Wachsmann-Hogiu S. Optimization and miniaturization of SE-ECL for potential-resolved, multi-color, multi-analyte detection. Biosens Bioelectron 2024; 257:116322. [PMID: 38678789 DOI: 10.1016/j.bios.2024.116322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 04/16/2024] [Accepted: 04/20/2024] [Indexed: 05/01/2024]
Abstract
Electrochemiluminescence (ECL) is a bioanalytical technique with numerous advantages, including the potential for high temporal and spatial resolution, a high signal-to-noise ratio, a broad dynamic range, and rapid measurement capabilities. To reduce the complexity of a multi-electrode approach, we use a single-electrode electrochemiluminescence (SE-ECL) configuration to achieve the simultaneous emission and detection of multiple colors for applications that require multiplexed detection of several analytes. This method exploits intrinsic differences in the electric potential applied along single electrodes built into electrochemical cells, enabling the achievement of distinct colors through selective excitation of ECL luminophores. We present results on the optimization of SE-ECL intensity for different channel lengths and widths, with sum intensities being 5 times larger for 6 cm vs. 2 cm channels and linearly increasing with the width of the channels. Furthermore, we demonstrated for the first time that applying Alternating Current (AC) voltage within the single electrode setup for driving the ECL reactions has a dramatic effect on the emitted light intensity, with square waveforms resulting in higher intensities vs sine waveforms. Additionally, multiplexed multicolor SE-ECL on a 6.5 mm × 3.6 mm CMOS semiconductor image sensor was demonstrated for the first time, with the ability to simultaneously distinguish four different colors, leading to the ability to measure multiple analytes.
Collapse
Affiliation(s)
- Reza Abbasi
- Department of Bioengineering, McGill University, Montreal, Canada
| | | |
Collapse
|
4
|
Qian M, Zeng Y, Li M, Gao Q, Zhang C, Qi H. Electrogenerated Chemiluminescence Biosensor for Quantization of Matrix Metalloproteinase-3 in Serum via Target-Induced Cleavage of Oligopeptide. BIOSENSORS 2024; 14:181. [PMID: 38667174 PMCID: PMC11047963 DOI: 10.3390/bios14040181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/30/2024] [Accepted: 04/04/2024] [Indexed: 04/28/2024]
Abstract
A highly sensitive and selective electrogenerated chemiluminescence (ECL) biosensor was developed for the determination of matrix metalloproteinase 3 (MMP-3) in serum via the target-induced cleavage of an oligopeptide. One ECL probe (named as Ir-peptide) was synthesized by covalently linking a new cyclometalated iridium(III) complex ([(3-pba)2Ir(bpy-COOH)](PF6)) (3-pba = 3-(2-pyridyl) benzaldehyde, bpy-COOH = 4'-methyl-2,2'-bipyridine-4-carboxylic acid) with an oligopeptide (CGVPLSLTMGKGGK). An ECL biosensor was fabricated by firstly casting Nafion and gold nanoparticles (AuNPs) on a glassy carbon electrode and then self-assembling both of the ECL probes, 6-mercapto-1-hexanol and zwitterionic peptide, on the electrode surface, from which the AuNPs could be used to amplify the ECL signal and Ir-peptide could serve as an ECL probe to detect the MMP-3. Thanks to the MMP-3-induced cleavage of the oligopeptide contributing to the decrease in ECL intensity and the amplification of the ECL signal using AuNPs, the ECL biosensor could selectively and sensitively quantify MMP-3 in the concentration range of 10-150 ng·mL-1 and with both a limit of quantification (26.7 ng·mL-1) and a limit of detection (8.0 ng·mL-1) via one-step recognition. In addition, the developed ECL biosensor showed good performance in the quantization of MMP-3 in serum samples, with a recovery of 92.6% ± 2.8%-105.6% ± 5.0%. An increased level of MMP-3 was found in the serum of rheumatoid arthritis patients compared with that of healthy people. This work provides a sensitive and selective biosensing method for the detection of MMP-3 in human serum, which is promising in the identification of patients with rheumatoid arthritis.
Collapse
Affiliation(s)
| | | | | | | | | | - Honglan Qi
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062, China; (M.Q.); (M.L.); (Q.G.)
| |
Collapse
|
5
|
Alipourfard I, Darvishi M, Khalighfard A, Ghazi F, Mobed A. Nanomaterial-based methods for sepsis management. Enzyme Microb Technol 2024; 174:110380. [PMID: 38147783 DOI: 10.1016/j.enzmictec.2023.110380] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 11/26/2023] [Accepted: 12/12/2023] [Indexed: 12/28/2023]
Abstract
Sepsis is a serious disease caused by an impaired host immune response to infection, resulting in organ dysfunction, tissue damage and is responsible for high in-hospital mortality (approximately 20%). Recently, WHO documented sepsis as a global health priority. Nevertheless, there is still no effective and specific therapy for clinically detecting sepsis. Nanomaterial-based approaches have appeared as promising tools for identifying bacterial infections. In this review, recent biosensors are introduced and summarized as nanomaterial-based platforms for sepsis management and severe complications. Biosensors can be used as tools for the diagnosis and treatment of sepsis and as nanocarriers for drug delivery. In general, diagnostic methods for sepsis-associated bacteria, biosensors developed for this purpose are presented in detail, and their strengths and weaknesses are discussed. In other words, readers of this article will gain a comprehensive understanding of biosensors and their applications in sepsis management.
Collapse
Affiliation(s)
- Iraj Alipourfard
- Institute of Biology, Biotechnology and Environmental Protection, Faculty of Natural Sciences, University of Silesia, Katowice, Poland
| | - Mohammad Darvishi
- Infectious Diseases and Tropical Medicine Research Center (IDTMRC), Department of Aerospace and Subaquatic Medicine, AJA University of Medical Sciences, Tehran, Iran
| | - Arghavan Khalighfard
- Department of Nursing and Midwifery٫ Faculty of Midwifery٬ Zanjan University of Medical Sciences, Zanjan, Iran
| | - Farhood Ghazi
- Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz 5154853431, Iran
| | - Ahmad Mobed
- Infectious and Tropical Diseases Research Center, Clinical Research Institute, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
6
|
Gutiérrez-Gálvez L, García-Fernández D, Barrio MD, Luna M, Torres Í, Zamora F, Navío C, Milán-Rois P, Castellanos M, Abreu M, Cantón R, Galán JC, Somoza Á, Miranda R, García-Mendiola T, Lorenzo E. Free PCR virus detection via few-layer bismuthene and tetrahedral DNA nanostructured assemblies. Talanta 2024; 269:125405. [PMID: 37984235 DOI: 10.1016/j.talanta.2023.125405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/07/2023] [Accepted: 11/11/2023] [Indexed: 11/22/2023]
Abstract
In this work we describe a highly sensitive method based on a biocatalyzed electrochemiluminescence approach. The system combines, for the first time, the use of few-layer bismuthene (FLB) as a platform for the oriented immobilization of tetrahedral DNA nanostructures (TDNs) specifically designed and synthetized to detect a specific SARS-CoV-2 gene sequence. In one of its vertices, these TDNs contain a DNA capture probe of the open reading frame 1 ab (ORF1ab) of the virus, available for the biorecognition of the target DNA/RNA. At the other three vertices, there are thiol groups that enable the stable anchoring/binding to the FLB surface. This novel geometry/approach enables not only the binding of the TDNs to surfaces, but also the orientation of the capture probe in a direction normal to the bismuthine surface so that it is readily accessible for binding/recognition of the specific SARS-CoV-2 sequence. The analytical signal is based on the anodic electrochemiluminescence (ECL) intensity of luminol which, in turn, arises as a result of the reaction with H2O2, generated by the enzymatic reaction of glucose oxidation, catalyzed by the biocatalytic label avidin-glucose oxidase conjugate (Av-GOx), which acts as co-reactant in the electrochemiluminescent reaction. The method exhibits a limit of detection (LOD) of 4.31 aM and a wide linear range from 14.4 aM to 1.00 μM, and its applicability was confirmed by detecting SARS-CoV-2 in nasopharyngeal samples from COVID-19 patients without the need of any amplification process.
Collapse
Affiliation(s)
- Laura Gutiérrez-Gálvez
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid (UAM), 28049, Madrid, Spain
| | - Daniel García-Fernández
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid (UAM), 28049, Madrid, Spain
| | - Melisa Del Barrio
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid (UAM), 28049, Madrid, Spain
| | - Mónica Luna
- Instituto de Micro y Nanotecnología IMN-CNM, CSIC (CEI UAM+CSIC), 28760, Tres Cantos, Madrid, Spain
| | - Íñigo Torres
- Departamento de Química Inorgánica and Condensed Matter Physics Center (IFIMAC), Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Félix Zamora
- Departamento de Química Inorgánica and Condensed Matter Physics Center (IFIMAC), Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Cristina Navío
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| | - Paula Milán-Rois
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| | | | - Melanie Abreu
- Servicio de Microbiología, Hospital Universitario Ramón y Cajal and Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS), 28034, Madrid, Spain
| | - Rafael Cantón
- CIBER de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Juan Carlos Galán
- Servicio de Microbiología, Hospital Universitario Ramón y Cajal and Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS), 28034, Madrid, Spain; Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| | - Álvaro Somoza
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| | - Rodolfo Miranda
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| | - Tania García-Mendiola
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid (UAM), 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain.
| | - Encarnación Lorenzo
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid (UAM), 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain; IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| |
Collapse
|
7
|
Fang J, Dai L, Feng R, Ren X, Wu D, Cao W, Wei Q, Ma H. Antioxidant Cascade Modulated Electrochemiluminescence by a Biomimetic Metal-Organic Framework with Dual Enzymatic Activity for Disease Marker Immunoassays. Anal Chem 2023; 95:14143-14149. [PMID: 37675866 DOI: 10.1021/acs.analchem.3c03205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
High-performance electrochemiluminescence is a significant approach for the examination of disease biomarkers, and the utilization of innovative electrochemiluminescence detection systems represents a viable strategy to enhance the efficacy of ECL analysis. In this work, the biomimetic engineering metal-organic framework (MOF-818) has realized the ultrasensitive ECL immunoassay of disease markers based on the guidance of the free radical scavenging strategy provided by the antioxidant cascade. Initially, we synthesized a hydrogen-bonded organic framework (HOF) consisting of luminol and three active ligands based on simple room-temperature self-assembly. The luminol-HOF (L-HOF) showed more stable and brighter ECL luminescence activity than the monomer due to the nano-confinement enhancement of the coordinated luminol units. Subsequently, MOF-818 with biomimetic superoxide dismutase (SOD) and catalase (CAT) activities were recruited for the first time as quenching agents for sandwich immunoassay mode. The enzyme activity leads to the reverse transformation of superoxide anion radicals (O2-) and further antioxidant decomposition, decreasing in the responsiveness of luminol ECL signals. Using carcinoembryonic antigen (CEA) as an analytical model, a detection limit of 0.457 pg/mL was obtained within a detection range of 0.001-50 ng/mL. We believe that this novel sandwich sensing model based on enzyme activity provides a meaningful potential tool for precise detection, expanding the broader application of nanoenzymes in analysis.
Collapse
Affiliation(s)
- Jinglong Fang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Li Dai
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Ruiqing Feng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Xiang Ren
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Dan Wu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Wei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
- Department of Chemistry, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Hongmin Ma
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| |
Collapse
|
8
|
Yang F, Gong J, Li M, Jiang X, Zhang J, Liao M, Zhang H, Tremblay PL, Zhang T. Electrochemiluminescent CdS Quantum Dots Biosensor for Cancer Mutation Detection at Different Positions on Linear DNA Analytes. Anal Chem 2023; 95:14016-14024. [PMID: 37683084 DOI: 10.1021/acs.analchem.3c02649] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
PCR-based techniques routinely employed for the detection of mutated linear DNA molecules, including circulating tumor DNA (ctDNA), require large nucleotide sections on both sides of the mutation for primer annealing. This means that DNA fragments with a mutation positioned closer to the extremities are unlikely to be detected. Thus, sensors capable of recognizing linear DNA with characteristic mutations closer to the ends would be advantageous over the state-of-the-art approaches. Here, an electrochemiluminescence-resonance energy transfer (ECL-RET) biosensor comprising capped CdS quantum dots and hairpin DNA probes labeled with Au nanoparticles was developed for the detection of epidermal growth factor receptor (EGFR) ctDNA carrying the critical T790M lung cancer mutation. The ECL-RET system detected different DNA molecules including single-stranded 18-nucleotides (nt) and 40-nt as well as double-stranded 100-nt with the single nucleotide polymorphism (SNP) coding for T790M located either in the middle or only 7 nt from one end. For all target DNA, the sensor's limits of detection (LODs) were in the aM range, with excellent selectivity. It was the case of 100-nt target linear ctDNA fragments with LODs of 8.1 and 3.4 aM when the EGFR T790M SNP was either in the middle or at the end, respectively. These results show that ECL-RET systems can sense mutations in DNA fragments that would remain undetected by standard techniques.
Collapse
Affiliation(s)
- Fan Yang
- School of Chemistry, Chemical Engineering, and Life Science, Wuhan University of Technology, Wuhan, Hubei 430070, China
- Shaoxing Institute for Advanced Research, Wuhan University of Technology, Shaoxing, Zhejiang 312300, China
| | - JinBo Gong
- School of Chemistry, Chemical Engineering, and Life Science, Wuhan University of Technology, Wuhan, Hubei 430070, China
| | - Ming Li
- School of Resources and Environmental Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, China
| | - Xiangyang Jiang
- School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, China
| | - Jiawen Zhang
- Institut WUT-AMU, Wuhan University of Technology, Wuhan, Hubei 430070, China
| | - Meiyan Liao
- Department of Radiology, Zhongnan Hospital of Wuhan Uni-versity, Wuhan, Hubei 430071, China
| | - Hanfei Zhang
- Department of Radiology, Zhongnan Hospital of Wuhan Uni-versity, Wuhan, Hubei 430071, China
| | - Pier-Luc Tremblay
- School of Chemistry, Chemical Engineering, and Life Science, Wuhan University of Technology, Wuhan, Hubei 430070, China
- Shaoxing Institute for Advanced Research, Wuhan University of Technology, Shaoxing, Zhejiang 312300, China
- Institut WUT-AMU, Wuhan University of Technology, Wuhan, Hubei 430070, China
| | - Tian Zhang
- School of Chemistry, Chemical Engineering, and Life Science, Wuhan University of Technology, Wuhan, Hubei 430070, China
- Shaoxing Institute for Advanced Research, Wuhan University of Technology, Shaoxing, Zhejiang 312300, China
- School of Resources and Environmental Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, China
- School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, China
- Institut WUT-AMU, Wuhan University of Technology, Wuhan, Hubei 430070, China
| |
Collapse
|
9
|
Zhang Z. Recent Progress in Biosensors Based on Biorecognition Molecules. BIOSENSORS 2023; 13:842. [PMID: 37754076 PMCID: PMC10526284 DOI: 10.3390/bios13090842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 08/23/2023] [Indexed: 09/28/2023]
Abstract
Biosensors are considered a popular technology to rapidly detect targets, and are generally composed of biorecognition molecules that specifically capture analytes and signal elements [...].
Collapse
Affiliation(s)
- Zhen Zhang
- School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China
| |
Collapse
|
10
|
Dong J, Li G, Xia L, Li H. Microtrap-assisted microfluidic magnetic separation and concentration for ultrasensitive immunoassays of biomarkers. J Chromatogr A 2023; 1699:464021. [PMID: 37126879 DOI: 10.1016/j.chroma.2023.464021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 04/07/2023] [Accepted: 04/21/2023] [Indexed: 05/03/2023]
Abstract
Precise and accurate quantitation of important biomarkers is significant, especially in early-stage diseases diagnosis. To realized effective biosample preparation and trace-level biomarker detection, a microtrap-assisted microfluidic magnetic immunoassays (μMI) method was developed in this work. A microtrap was fabricated inside the straight microchannel of μMI device to help magnetic separation and concentration of immunocomplexes. These immunocomplexes were enriched in microtrap of μMI device to accomplish selective and sensitive biomarker detection. Horseradish peroxidase-labeled magnetic beads were employed to evaluate assay feasibility and microtrap effect on assay sensitivity. The microtrap-assisted μMI was then applied for model biomarkers detection. The limits of detection of μMI were 0.025 pg/mL for monocyte chemoattractant protein-1 (MCP-1) and 0.021 pg/mL for matrix metalloproteinase-9 (MMP-9), which corresponded up to 2014-fold sensitivity improvement compared to their standard microwell enzyme-linked immunosorbent assay (ELISA) results. In addition, the selectivity and reproducibility of microtrap-assisted μMI were confirmed. In clinical serum sample analysis, recoveries of 91.3%-106.7% with relative standard deviations less than 6.1% were obtained for MCP-1 and MMP-9, and method accuracy was verified by commercial ELISA kit. The developed μMI can accomplish ultratrace biomarker detection offering practical tool for laboratorial and clinical research.
Collapse
Affiliation(s)
- Jianwei Dong
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China.
| | - Ling Xia
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China.
| | - He Li
- School of Chemistry, South China Normal University, Guangzhou 510006, China
| |
Collapse
|
11
|
Tamiya E, Osaki S, Tsuchihashi T, Ushijima H, Tsukinoki K. Point-of-Care Diagnostic Biosensors to Monitor Anti-SARS-CoV-2 Neutralizing IgG/sIgA Antibodies and Antioxidant Activity in Saliva. BIOSENSORS 2023; 13:167. [PMID: 36831933 PMCID: PMC9953869 DOI: 10.3390/bios13020167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/15/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
Monitoring biomarkers is a great way to assess daily physical condition, and using saliva instead of blood samples is more advantageous as the process is simple and allows individuals to test themselves. In the present study, we analyzed the titers of neutralizing antibodies, IgG and secretory IgA (sIgA), in response to the SARS-CoV-2 vaccine, in saliva. A total of 19 saliva and serum samples were collected over a 10-month period 3 weeks after the first vaccine, 8 months after the second vaccine, and 1 month after the third vaccine. The ranges of antibody concentrations post-vaccination were: serum IgG: 81-15,000 U/mL, salivary IgG: 3.4-330 U/mL, and salivary IgA: 58-870 ng/mL. A sharp increase in salivary IgG levels was observed after the second vaccination. sIgA levels also showed an increasing trend. A correlation with trends in serum IgG levels was observed, indicating the possibility of using saliva to routinely assess vaccine efficacy. The electrochemical immunosensor assay developed in this study based on the gold-linked electrochemical immunoassay, and the antioxidant activity measurement based on luminol electrochemiluminescence (ECL), can be performed using portable devices, which would prove useful for individual-based diagnosis using saliva samples.
Collapse
Affiliation(s)
- Eiichi Tamiya
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
- SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan
| | - Shuto Osaki
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| | | | - Hiromi Ushijima
- BioDevice Technology Ltd., 2-3 Asahidai, Nomi 923-1211, Ishikawa, Japan
| | - Keiichi Tsukinoki
- Department of Environmental Pathology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-0003, Kanagawa, Japan
| |
Collapse
|