1
|
Glynn AM, Lawrence YR, Dawson LA, Barry AS. The use of precision radiotherapy for the management of cancer related pain in the abdomen. Curr Opin Support Palliat Care 2024:01263393-990000000-00102. [PMID: 39668687 DOI: 10.1097/spc.0000000000000738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2024]
Abstract
PURPOSE OF REVIEW Abdominal pain due to cancer is a significant and debilitating symptom for cancer patients, which is commonly undertreated. Radiotherapy (RT) for the management of abdominal cancer pain is underused, with limited awareness of its benefit. This review presents a discussion on current precision RT options for the management of cancer pain in the abdomen. RECENT FINDINGS Precision RT focuses on delivering targeted and effective radiation doses while minimizing damage to surrounding healthy tissues. In patients with primary or secondary liver cancer, RT has been shown to significantly improve liver related cancer pain in the majority of patients. Also, symptom sequelae of tumour thrombus may be relieved with the use of palliative RT. Similarly, single dose, high precision stereotactic RT to the celiac plexus has been shown to significantly improve pain in patients with pancreatic cancer. Pain response for adrenal metastases has been less commonly investigated, but small series suggest that stereotactic body RT may reduce or alleviate pain. SUMMARY RT is an effective option for the treatment of abdominal cancer pain. RT should be considered within the multidisciplinary treatment armamentarium, and may be successfully integrated, alone or in conjunction with other treatment modalities, in abdominal cancer related pain.
Collapse
Affiliation(s)
- Aisling M Glynn
- Radiation Medicine Program, Princess Margaret Cancer Centre
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Yaacov R Lawrence
- The Benjamin Davidai Dep. Radiation Oncology, Sheba Medical Center, Tel HaShomer, Israel
- Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Department of Radiation Oncology, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Laura A Dawson
- Radiation Medicine Program, Princess Margaret Cancer Centre
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Aisling S Barry
- Cancer Research@UCC, School of Medicine and Health, University College Cork, Cork, Ireland
- Department of Radiation Oncology, Cork University Hospital, Ireland
| |
Collapse
|
2
|
Martin-Paulpeter RM, Jensen PJ, Perles LA, Sawakuchi GO, Das P, Koay EJ, Koong AC, Ludmir EB, Niedzielski JS, Beddar S. Daily Diagnostic Quality Computed Tomography-on-Rails (CTOR) Image Guidance for Abdominal Stereotactic Body Radiation Therapy (SBRT). Cancers (Basel) 2024; 16:3770. [PMID: 39594725 PMCID: PMC11591933 DOI: 10.3390/cancers16223770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Accepted: 11/06/2024] [Indexed: 11/28/2024] Open
Abstract
BACKGROUND/OBJECTIVES Stereotactic body radiation therapy (SBRT) for abdominal targets faces a variety of challenges, including motion caused by the respiration and digestion and a relatively poor level of contrast between the tumor and the surrounding tissues. Breath-hold treatments with computed tomography-on-rails (CTOR) image guidance is one way of addressing these challenges, allowing for both the tumor and normal tissues to be well-visualized. Using isodose lines (IDLs) from CT simulations as a guide, the anatomical information can be used to shift the alignment or trigger a replan, such that normal tissues receive acceptable doses of radiation. METHODS This study aims to describe the workflow involved when using CTOR for pancreas and liver SBRT and demonstrates its effectiveness through several case studies. RESULTS In these case studies, using the anatomical information gained through diagnostic-quality CT guidance to make slight adjustments to the alignment, resulted in reductions in the maximum dose to the stomach. CONCLUSIONS High-quality imaging, such as CTOR, and the use of IDLs to estimate the doses to OARs, enable the safe delivery of SBRT, without the added complexity and resource commitment required by daily online adaptive planning.
Collapse
Affiliation(s)
- Rachael M. Martin-Paulpeter
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - P. James Jensen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Luis A. Perles
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Gabriel O. Sawakuchi
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Prajnan Das
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Eugene J. Koay
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Albert C. Koong
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Ethan B. Ludmir
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Joshua S. Niedzielski
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| | - Sam Beddar
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA (L.A.P.)
| |
Collapse
|
3
|
Semeniuk O, Shessel A, Velec M, Fodor T, Rocca CC, Barry A, Lukovic J, Yan M, Mesci A, Kim J, Wong R, Dawson LA, Hosni A, Stanescu T. Development and validation of an MR-driven dose-of-the-day procedure for online adaptive radiotherapy in upper gastrointestinal cancer patients. Phys Med Biol 2024; 69:165009. [PMID: 39048106 DOI: 10.1088/1361-6560/ad6745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 07/23/2024] [Indexed: 07/27/2024]
Abstract
Objective.To develop and validate a dose-of-the-day (DOTD) treatment plan verification procedure for liver and pancreas cancer patients treated with an magnetic resonance (MR)-Linac system.Approach.DOTD was implemented as an automated process that uses 3D datasets collected during treatment delivery. Particularly, the DOTD pipeline's input included the adapt-to-shape (ATS) plan-i.e. 3D-MR dataset acquired at beginning of online session, anatomical contours, dose distribution-and 3D-MR dataset acquired during beam-on (BON). The DOTD automated analysis included (a) ATS-to-BON image intensity-based deformable image registration (DIR), (b) ATS-to-BON contours mapping via DIR, (c) BON-to-ATS contours copying through rigid registration, (d) determining ATS-to-BON dosimetric differences, and (e) PDF report generation. The DIR process was validated by two expert reviewers. ATS-plans were recomputed on BON datasets to assess dose differences. DOTD analysis was performed retrospectively for 75 treatment fractions (12-liver and 5-pancreas patients).Main results.The accuracy of DOTD process relied on DIR and mapped contours quality. Most DIR-generated contours (99.6%) were clinically acceptable. DICE correlated with depreciation of DIR-based region of interest mapping process. The ATS-BON plan difference was found negligible (<1%). The duodenum and large bowel exhibited highest variations, 24% and 39% from fractional values, for 5-fraction liver and pancreas. For liver 1-fraction, a 62% variation was observed for duodenum.Significance.The DOTD methodology provides an automated approach to quantify 3D dosimetric differences between online plans and their delivery. This analysis offers promise as a valuable tool for plan quality assessment and decision-making in the verification stage of the online workflow.
Collapse
Affiliation(s)
- Oleksii Semeniuk
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | - Andrea Shessel
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | - Michael Velec
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | - Tudor Fodor
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | - Cathy-Carpino Rocca
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | - Aisling Barry
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Jelena Lukovic
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Michael Yan
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Aruz Mesci
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - John Kim
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Rebecca Wong
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Laura A Dawson
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Ali Hosni
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
| | - Teo Stanescu
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| |
Collapse
|
4
|
Buchele C, Renkamp CK, Regnery S, Behnisch R, Rippke C, Schlüter F, Hoegen-Saßmannshausen P, Debus J, Hörner-Rieber J, Alber M, Klüter S. Intrafraction organ movement in adaptive MR-guided radiotherapy of abdominal lesions - dosimetric impact and how to detect its extent in advance. Radiat Oncol 2024; 19:80. [PMID: 38918828 PMCID: PMC11202341 DOI: 10.1186/s13014-024-02466-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Accepted: 06/10/2024] [Indexed: 06/27/2024] Open
Abstract
INTRODUCTION Magnetic resonance guided radiotherapy (MRgRT) allows daily adaptation of treatment plans to compensate for positional changes of target volumes and organs at risk (OARs). However, current adaptation times are relatively long and organ movement occurring during the adaptation process might offset the benefit gained by adaptation. The aim of this study was to evaluate the dosimetric impact of these intrafractional changes. Additionally, a method to predict the extent of organ movement before the first treatment was evaluated in order to have the possibility to compensate for them, for example by adding additional margins to OARs. MATERIALS & METHODS Twenty patients receiving adaptive MRgRT for treatment of abdominal lesions were retrospectively analyzed. Magnetic resonance (MR) images acquired at the start of adaptation and immediately before irradiation were used to calculate adapted and pre-irradiation dose in OARs directly next to the planning target volume. The extent of organ movement was determined on MR images acquired during simulation sessions and adaptive treatments, and their agreement was evaluated. Correlation between the magnitude of organ movement during simulation and the duration of simulation session was analyzed in order to assess whether organ movement might be relevant even if the adaptation process could be accelerated in the future. RESULTS A significant increase in dose constraint violations was observed from adapted (6.9%) to pre-irradiation (30.2%) dose distributions. Overall, OAR dose increased significantly by 4.3% due to intrafractional organ movement. Median changes in organ position of 7.5 mm (range 1.5-10.5 mm) were detected within a median time of 17.1 min (range 1.6-28.7 min). Good agreement was found between the range of organ movement during simulation and adaptation (66.8%), especially if simulation sessions were longer and multiple MR images were acquired. No correlation was determined between duration of simulation sessions and magnitude of organ movement. CONCLUSION Intrafractional organ movement can impact dose distributions and lead to violations of OAR tolerance doses, which impairs the benefit of daily on-table plan adaptation. By application of simulation images, the extent of intrafractional organ movement can be predicted, which possibly allows to compensate for them.
Collapse
Affiliation(s)
- Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany.
- Medical Faculty, Heidelberg University, Heidelberg, Baden-Württemberg, Germany.
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
| | - Sebastian Regnery
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Rouven Behnisch
- Institute of Medical Biometry (IMBI), Heidelberg University, Heidelberg, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
| | - Fabian Schlüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
| | - Philipp Hoegen-Saßmannshausen
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
- Medical Faculty, Heidelberg University, Heidelberg, Baden-Württemberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
- Medical Faculty, Heidelberg University, Heidelberg, Baden-Württemberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany.
| |
Collapse
|
5
|
Peltenburg JE, Hosni A, Bahij R, Boeke S, Braam PM, Hall WA, Intven MP, Nicosia L, Sonke JJ, Witte M, Nowee ME, Janssen T. Interobserver variation in tumor delineation of liver metastases using Magnetic Resonance Imaging. Phys Imaging Radiat Oncol 2024; 30:100592. [PMID: 38912009 PMCID: PMC11190710 DOI: 10.1016/j.phro.2024.100592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/24/2024] [Accepted: 05/25/2024] [Indexed: 06/25/2024] Open
Abstract
Background and purpose Magnetic Resonance Imaging (MRI) guided stereotactic body radiotherapy (SBRT) of liver metastases is an upcoming high-precision non-invasive treatment. Interobserver variation (IOV) in tumor delineation, however, remains a relevant uncertainty for planning target volume (PTV) margins. The aims of this study were to quantify IOV in MRI-based delineation of the gross tumor volume (GTV) of liver metastases and to detect patient-specific factors influencing IOV. Materials and methods A total of 22 patients with liver metastases from three primary tumor origins were selected (colorectal(8), breast(6), lung(8)). Delineation guidelines and planning MRI-scans were provided to eight radiation oncologists who delineated all GTVs. All delineations were centrally peer reviewed to identify outliers not meeting the guidelines. Analyses were performed both in- and excluding outliers. IOV was quantified as the standard deviation (SD) of the perpendicular distance of each observer's delineation towards the median delineation. The correlation of IOV with shape regularity, tumor origin and volume was determined. Results Including all delineations, average IOV was 1.6 mm (range 0.6-3.3 mm). From 160 delineations, in total fourteen single delineations were marked as outliers after peer review. After excluding outliers, the average IOV was 1.3 mm (range 0.6-2.3 mm). There was no significant correlation between IOV and tumor origin or volume. However, there was a significant correlation between IOV and regularity (Spearman's ρs = -0.66; p = 0.002). Conclusion MRI-based IOV in tumor delineation of liver metastases was 1.3-1.6 mm, from which PTV margins for IOV can be calculated. Tumor regularity and IOV were significantly correlated, potentially allowing for patient-specific margin calculation.
Collapse
Affiliation(s)
- Julia E. Peltenburg
- Department of Radiation Oncology, The Netherlands Cancer Institute, Postal Address: Plesmanlaan 121, 1066CX Amsterdam, The Netherlands
| | - Ali Hosni
- Department of Radiation Oncology, Princess Margaret Cancer Center, Postal Address: 610 University Avenue, Toronto, ON M5G 2M9, Canada
| | - Rana Bahij
- Department of Oncology, Odense University Hospital, Postal Address: J. B. Winsløws Vej 4, 5000 Odense, Denmark
| | - Simon Boeke
- Department of Radiation Oncology, Tübingen University Hospital, Postal Address: Geissweg 3, 72076 Tübingen, Germany
| | - Pètra M. Braam
- Department of Radiation Oncology, Radboud University Medical Center, Postal Address: Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - William A. Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Postal Address: 9200 W. Wisconsin Avenue, Milwaukee, WI 53226, USA
| | - Martijn P.W. Intven
- Department of Radiation Oncology, University Medical Center Utrecht, Postal Address: Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Luca Nicosia
- Department of Radiation Oncology, Sacro Cuore Don Calabria Hospital, Postal Address: Viale Luigi Rizzardi, 4, 37024, Negrar di Valpolicella VR, Italy
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Postal Address: Plesmanlaan 121, 1066CX Amsterdam, The Netherlands
| | - Marnix Witte
- Department of Radiation Oncology, The Netherlands Cancer Institute, Postal Address: Plesmanlaan 121, 1066CX Amsterdam, The Netherlands
| | - Marlies E. Nowee
- Department of Radiation Oncology, The Netherlands Cancer Institute, Postal Address: Plesmanlaan 121, 1066CX Amsterdam, The Netherlands
| | - Tomas Janssen
- Department of Radiation Oncology, The Netherlands Cancer Institute, Postal Address: Plesmanlaan 121, 1066CX Amsterdam, The Netherlands
| |
Collapse
|
6
|
Fink CA, Buchele C, Baumann L, Liermann J, Hoegen P, Ristau J, Regnery S, Sandrini E, König L, Rippke C, Bonekamp D, Schlemmer HP, Debus J, Koerber SA, Klüter S, Hörner-Rieber J. Dosimetric benefit of online treatment plan adaptation in stereotactic ultrahypofractionated MR-guided radiotherapy for localized prostate cancer. Front Oncol 2024; 14:1308406. [PMID: 38425342 PMCID: PMC10902126 DOI: 10.3389/fonc.2024.1308406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 01/24/2024] [Indexed: 03/02/2024] Open
Abstract
Background Apart from superior soft tissue contrast, MR-guided stereotactic body radiation therapy (SBRT) offers the chance for daily online plan adaptation. This study reports on the comparison of dose parameters before and after online plan adaptation in MR-guided SBRT of localized prostate cancer. Materials and methods 32 consecutive patients treated with ultrahypofractionated SBRT for localized prostate cancer within the prospective SMILE trial underwent a planning process for MR-guided radiotherapy with 37.5 Gy applied in 5 fractions. A base plan, derived from MRI simulation at an MRIdian Linac, was registered to daily MRI scans (predicted plan). Following target and OAR recontouring, the plan was reoptimized based on the daily anatomy (adapted plan). CTV and PTV coverage and doses at OAR were compared between predicted and adapted plans using linear mixed regression models. Results In 152 out of 160 fractions (95%), an adapted radiation plan was delivered. Mean CTV and PTV coverage increased by 1.4% and 4.5% after adaptation. 18% vs. 95% of the plans had a PTV coverage ≥95% before and after online adaptation, respectively. 78% vs. 100% of the plans had a CTV coverage ≥98% before and after online adaptation, respectively. The D0.2cc for both bladder and rectum were <38.5 Gy in 93% vs. 100% before and after online adaptation. The constraint at the urethra with a dose of <37.5 Gy was achieved in 59% vs. 93% before and after online adaptation. Conclusion Online adaptive plan adaptation improves target volume coverage and reduces doses to OAR in MR-guided SBRT of localized prostate cancer. Online plan adaptation could potentially further reduce acute and long-term side effects and improve local failure rates in MR-guided SBRT of localized prostate cancer.
Collapse
Affiliation(s)
- Christoph A. Fink
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Lukas Baumann
- Institute of Medical Biometry (IMBI), University of Heidelberg, Heidelberg, Germany
| | - Jakob Liermann
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Philipp Hoegen
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Jonas Ristau
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Sebastian Regnery
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Elisabetta Sandrini
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Laila König
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - David Bonekamp
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- German Cancer Consortium (DKTK), Partner Side Heidelberg, Heidelberg, Germany
| | | | - Juergen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- German Cancer Consortium (DKTK), Partner Side Heidelberg, Heidelberg, Germany
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Stefan A. Koerber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Department of Radiation Oncology, Barmherzige Brueder Hospital Regensburg, Regensburg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
7
|
Abstract
Magnetic resonance imaging-guided radiation therapy (MRIgRT) has improved soft tissue contrast over computed tomography (CT) based image-guided RT. Superior visualization of the target and surrounding radiosensitive structures has the potential to improve oncological outcomes partly due to safer dose-escalation and adaptive planning. In this review, we highlight the workflow of adaptive MRIgRT planning, which includes simulation imaging, daily MRI, identifying isocenter shifts, contouring, plan optimization, quality control, and delivery. Increased utilization of MRIgRT will depend on addressing technical limitations of this technology, while addressing treatment efficacy, cost-effectiveness, and workflow training.
Collapse
Affiliation(s)
- Cecil M Benitez
- Department of Radiation Oncology, UCLA Medical Center, Los Angeles, CA
| | - Michael D Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida; Miami, FL
| | - Luise A Künzel
- National Center for Tumor Diseases (NCT), Dresden; German Cancer Research Center (DKFZ), Heidelberg; Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden; Helmholtz-Zentrum Dresden - Rossendorf (HZDR), Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.; OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden Rossendorf, Dresden, Germany
| | - Daniela Thorwarth
- Department of Radiation Oncology, Section for Biomedical Physics, University of Tübingen, Tübingen, Germany..
| |
Collapse
|
8
|
Xiong Y, Rabe M, Rippke C, Kawula M, Nierer L, Klüter S, Belka C, Niyazi M, Hörner-Rieber J, Corradini S, Landry G, Kurz C. Impact of daily plan adaptation on accumulated doses in ultra-hypofractionated magnetic resonance-guided radiation therapy of prostate cancer. Phys Imaging Radiat Oncol 2024; 29:100562. [PMID: 38463219 PMCID: PMC10924058 DOI: 10.1016/j.phro.2024.100562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/18/2024] [Accepted: 02/19/2024] [Indexed: 03/12/2024] Open
Abstract
Background and purpose Ultra-hypofractionated online adaptive magnetic resonance-guided radiotherapy (MRgRT) is promising for prostate cancer. However, the impact of online adaptation on target coverage and organ-at-risk (OAR) sparing at the level of accumulated dose has not yet been reported. Using deformable image registration (DIR)-based accumulation, we compared the delivered adapted dose with the simulated non-adapted dose. Materials and methods Twenty-three prostate cancer patients treated at two clinics with 0.35 T magnetic resonance-guided linear accelerator (MR-linac) following the same treatment protocol (5 × 7.5 Gy with urethral sparing and daily adaptation) were included. The fraction MR images were deformably registered to the planning MR image. Both non-adapted and adapted fraction doses were accumulated with the corresponding vector fields. Two DIR approaches were implemented. PTV* (planning target volume minus urethra+2mm) D95%, CTV* (clinical target volume minus urethra) D98%, and OARs (urethra+2mm, bladder, and rectum) D0.2cc, were evaluated. Statistical significance was inferred from a two-tailed Wilcoxon signed-rank test (p < 0.05). Results Normalized to the baseline, the accumulated PTV* D95% increased significantly by 2.7 % ([1.5, 4.3]%) through adaptation, and the CTV* D98% by 1.2 % ([0.1, 1.7]%). For the OARs after adaptation, accumulated bladder D0.2cc decreased by 0.4 % ([-1.2, 0.4]%), urethra+2mmD0.2cc by 0.8 % ([-1.6, -0.1]%), while rectum D0.2cc increased by 2.6 % ([1.2, 4.9]%). For all patients, rectum D0.2cc was still below the clinical constraint. Results of both DIR approaches differed on average by less than 0.2 %. Conclusions Online adaptation in MRgRT improved target coverage and OARs sparing at the level of accumulated dose.
Collapse
Affiliation(s)
- Yuqing Xiong
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Moritz Rabe
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Maria Kawula
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Lukas Nierer
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology, National Center for Radiation Oncology, Heidelberg, Germany
| | - Claus Belka
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
- German Cancer Consortium (DKTK), Partner site Munich, a Partnership between DKFZ and LMU University Hospital Munich, Germany
- Bavarian Cancer Research Center (BZKF), Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology, National Center for Radiation Oncology, Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center, Heidelberg, Germany
- National Center for Tumor Diseases, Heidelberg, Germany
- German Cancer Consortium (DKTK), Heidelberg, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
9
|
Regnery S, Leiner L, Buchele C, Hoegen P, Sandrini E, Held T, Deng M, Eichkorn T, Rippke C, Renkamp CK, König L, Lang K, Adeberg S, Debus J, Klüter S, Hörner-Rieber J. Comparison of different dose accumulation strategies to estimate organ doses after stereotactic magnetic resonance-guided adaptive radiotherapy. Radiat Oncol 2023; 18:92. [PMID: 37248504 DOI: 10.1186/s13014-023-02284-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 05/17/2023] [Indexed: 05/31/2023] Open
Abstract
INTRODUCTION Re-irradiation is frequently performed in the era of precision oncology, but previous doses to organs-at-risk (OAR) must be assessed to avoid cumulative overdoses. Stereotactic magnetic resonance-guided online adaptive radiotherapy (SMART) enables highly precise ablation of tumors close to OAR. However, OAR doses may change considerably during adaptive treatment, which complicates potential re-irradiation. We aimed to compare the baseline plan with different dose accumulation techniques to inform re-irradiation. PATIENTS & METHODS We analyzed 18 patients who received SMART to lung or liver tumors inside prospective databases. Cumulative doses were calculated inside the planning target volumes (PTV) and OAR for the adapted plans and theoretical non-adapted plans via (1) cumulative dose volume histograms (DVH sum plan) and (2) deformable image registration (DIR)-based dose accumulation to planning images (DIR sum plan). We compared cumulative dose parameters between the baseline plan, DVH sum plan and DIR sum plan using equivalent doses in 2 Gy fractions (EQD2). RESULTS Individual patients presented relevant increases of near-maximum doses inside the proximal bronchial tree, spinal cord, heart and gastrointestinal OAR when comparing adaptive treatment to the baseline plans. The spinal cord near-maximum doses were significantly increased in the liver patients (D2% median: baseline 6.1 Gy, DIR sum 8.1 Gy, DVH sum 8.4 Gy, p = 0.04; D0.1 cm³ median: baseline 6.1 Gy, DIR sum 8.1 Gy, DVH sum 8.5 Gy, p = 0.04). Three OAR overdoses occurred during adaptive treatment (DIR sum: 1, DVH sum: 2), and four more intense OAR overdoses would have occurred during non-adaptive treatment (DIR sum: 4, DVH sum: 3). Adaptive treatment maintained similar PTV coverages to the baseline plans, while non-adaptive treatment yielded significantly worse PTV coverages in the lung (D95% median: baseline 86.4 Gy, DIR sum 82.4 Gy, DVH sum 82.2 Gy, p = 0.006) and liver patients (D95% median: baseline 87.4 Gy, DIR sum 82.1 Gy, DVH sum 81.1 Gy, p = 0.04). CONCLUSION OAR doses can increase during SMART, so that re-irradiation should be planned based on dose accumulations of the adapted plans instead of the baseline plan. Cumulative dose volume histograms represent a simple and conservative dose accumulation strategy.
Collapse
Affiliation(s)
- Sebastian Regnery
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Lukas Leiner
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Philipp Hoegen
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Elisabetta Sandrini
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Thomas Held
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Maximilian Deng
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Tanja Eichkorn
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Laila König
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Kristin Lang
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Sebastian Adeberg
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
- National Center for Tumor diseases (NCT), Heidelberg, Germany.
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| |
Collapse
|
10
|
Weykamp F, Hoegen P, Regnery S, Katsigiannopulos E, Renkamp CK, Lang K, König L, Sandrini E, Meixner E, Rippke C, Buchele C, Liermann J, Debus J, Klüter S, Hörner-Rieber J. Long-Term Clinical Results of MR-Guided Stereotactic Body Radiotherapy of Liver Metastases. Cancers (Basel) 2023; 15:2786. [PMID: 37345123 DOI: 10.3390/cancers15102786] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/13/2023] [Accepted: 05/14/2023] [Indexed: 06/23/2023] Open
Abstract
(1) Background: Magnetic-resonance (MR)-guided stereotactic body radiotherapy (SBRT) allows for ablative, non-invasive treatment of liver metastases. However, long-term clinical outcome data are missing. (2) Methods: Patients received MR-guided SBRT with a MRIdian Linac between January 2019 and October 2021 and were part of an ongoing prospective observational registry. Local hepatic control (LHC), distant hepatic control (DHC), progression free survival (PFS) and overall survival (OS) were estimated with the Kaplan-Meier method. Toxicity was documented according to CTCAE (v.5.0). (3) Results: Forty patients were treated for a total of 54 liver metastases (56% with online plan adaptation). Median prescribed dose was 50 Gy in five fractions equal to a biologically effective dose (BED) (alpha/beta = 10 Gy) of 100 Gy. At 1 and 2 years, LHC was 98% and 75%, DHC was 34% and 15%, PFS was 21% and 5% and OS was 83% and 57%. Two-year LHC was higher in case of BED > 100 Gy (100% vs. 57%; log-rank p = 0.04). Acute grade 1 and 2 toxicity (mostly nausea) occurred in 26% and 7% of the patients, with no grade ≥ 3 event. (4) Conclusions: To our knowledge, this is the largest cohort of MR-guided liver SBRT. Long-term local control was promising and underscores the aim of achieving >100 Gy BED. Nonetheless, distant tumor control remains challenging.
Collapse
Affiliation(s)
- Fabian Weykamp
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Philipp Hoegen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Sebastian Regnery
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Efthimios Katsigiannopulos
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Kristin Lang
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Laila König
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Elisabetta Sandrini
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Eva Meixner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Jakob Liermann
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), Partner Side, 69120 Heidelberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| |
Collapse
|
11
|
Regnery S, Katsigiannopulos E, Hoegen P, Weykamp F, Sandrini E, Held T, Deng M, Eichkorn T, Buchele C, Rippke C, Renkamp CK, König L, Lang K, Thomas M, Winter H, Adeberg S, Klüter S, Debus J, Hörner-Rieber J. To fly or not to fly: Stereotactic MR-guided adaptive radiotherapy effectively treats ultracentral lung tumors with favorable long-term outcomes. Lung Cancer 2023; 179:107175. [PMID: 36965207 DOI: 10.1016/j.lungcan.2023.03.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/09/2023] [Accepted: 03/16/2023] [Indexed: 03/27/2023]
Abstract
BACKGROUND Stereotactic radiotherapy of ultracentral lung tumors (ULT) is challenging as it may cause overdoses to sensitive mediastinal organs with severe complications. We aimed to describe long-term outcomes after stereotactic magnetic resonance (MR)-guided online adaptive radiotherapy (SMART) as an innovative treatment of ULT. PATIENTS & METHODS We analyzed 36 patients that received SMART to 40 tumors between 02/2020 - 08/2021 inside prospective databases. ULT were defined by planning target volume (PTV) overlap with the proximal bronchial tree or esophagus. We calculated Kaplan Meier estimates for overall survival (OS) and progression-free survival (PFS), and competing risk estimates for the incidence of tumor progression and treatment-related toxicities. ULT patients (N = 16) were compared to non-ULT patients (N = 20). RESULTS Baseline characteristics were similar between ULT and non-ULT, but ULT were larger (median PTV: ULT 54.7 cm3, non-ULT 19.2 cm3). Median follow-up was 23.6 months. ULT and non-ULT showed a similar OS (2-years: ULT 67%, non-ULT 60%, p = 0.7) and PFS (2-years: ULT 37%, non-ULT 34%, p = 0.73). Progressions occurred mainly at distant sites (2-year incidence of distant progression: ULT 63%, non-ULT 61%, p = 0.77), while local tumor control was favorable (2-year incidence of local progression: ULT 7%, non-ULT 0%, p = 0.22). Treatment of ULT led to significantly more toxicities ≥ grade (G) 2 (ULT: 9 (56%), non-ULT: 1 (5%), p = 0.002). Most toxicities were moderate (G2). Two ULT patients developed high-grade toxicities: 1) esophagitis G3 and bronchial bleeding G4 after VEGF treatment, 2) bronchial bleeding G3. Estimated incidence of high-grade toxicities was 19% (3-48%) in ULT, and no treatment-related death occurred. CONCLUSION Our small series supports SMART as potentially effective treatment of ULT. SMART with careful fractionation could reduce severe complications, but treatment of ULT remains a high-risk procedure and needs careful benefit-risk-assessment.
Collapse
Affiliation(s)
- Sebastian Regnery
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Efthimios Katsigiannopulos
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Philipp Hoegen
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Fabian Weykamp
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Elisabetta Sandrini
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Thomas Held
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Maximilian Deng
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Tanja Eichkorn
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Laila König
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Kristin Lang
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Michael Thomas
- National Center for Tumor Diseases (NCT), Heidelberg, Germany; Department of Thoracic Oncology, Thoraxklinik at Heidelberg University Hospital, Roentgenstrasse 1, 69126 Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC-H), Member of the German Center for Lung Research (DZL), Heidelberg, Germany
| | - Hauke Winter
- National Center for Tumor Diseases (NCT), Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC-H), Member of the German Center for Lung Research (DZL), Heidelberg, Germany; Department of Thoracic Surgery, Thoraxklinik at Heidelberg University Hospital, Roentgenstrasse 1, 69126 Heidelberg, Germany
| | - Sebastian Adeberg
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany; Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany; Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| |
Collapse
|