1
|
Tan NK, Chan H, Lu Z, Zreiqat H, Lakhwani G, Lesani P, New EJ. Ultrasensitive Dual Fluorophore-Conjugated Carbon Dots for Intracellular pH Sensing in 3D Tumor Models. ACS APPLIED MATERIALS & INTERFACES 2024; 16:47303-47313. [PMID: 39215383 DOI: 10.1021/acsami.4c10836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
The dysregulation of pH has been linked to the onset of chronic conditions, such as cancer and neurological diseases. Consequently, the development of a highly sensitive tool for intracellular pH sensing is imperative to investigate the interplay between pH and the biochemical changes accompanying disease pathogenesis. Here, we present the development of a ratiometric fluorescent nanoprobe, NpRhoDot, designed for precisely measuring pH levels. We demonstrate its efficacy in sensitively reporting intracellular pH in monolayer A549 lung cancer cells, primary fibroblast cells, and 3D tumor spheroids derived from the DLD-1 colorectal adenocarcinoma cell line. NpRhoDot leverages a novel design, where stable carbon dots are functionalized with a pH-responsive ratiometric fluorescent probe comprising a naphthalimide-rhodamine moiety, NpRho1. This design confers NpRhoDot with the high pH sensitivity characteristics of organic fluorescent probes, along with excellent photostability up to 1 h and biocompatibility of carbon dots. Through one-photon and two-photon fluorescence microscopy, we validate the reliability of NpRhoDot for biosensing intracellular pH in monolayer and three-dimensional tumor models from pH 4 to 7.
Collapse
Affiliation(s)
- Nian Kee Tan
- School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
| | - Hazel Chan
- School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
| | - Zufu Lu
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Hala Zreiqat
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute, Sydney, NSW 2006, Australia
| | - Girish Lakhwani
- School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute, Sydney, NSW 2006, Australia
- Australian Research Council Centre of Excellence in Exciton Science, The University of Sydney, Sydney, NSW 2006, Australia
| | - Pooria Lesani
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute, Sydney, NSW 2006, Australia
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States of America
| | - Elizabeth J New
- School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute, Sydney, NSW 2006, Australia
- Australian Research Council Centre of Excellence for Innovations in Peptide and Protein Science, The University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
2
|
Ding L, Xu F, Luo B, Cheng L, Huang L, Jia Y, Ding J. Preparation of Hematoporphyrin-Poly(Lactic Acid) Nanoparticles Encapsulated Perfluoropentane/Salicylic Acid for Enhanced US/CEST MR Bimodal Imaging. Int J Nanomedicine 2024; 19:4589-4605. [PMID: 38799695 PMCID: PMC11127694 DOI: 10.2147/ijn.s454486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 05/07/2024] [Indexed: 05/29/2024] Open
Abstract
Background Medical imaging modalities, such as magnetic resonance imaging (MRI), ultrasound, and fluorescence imaging, have gained widespread acceptance in clinical practice for tumor diagnosis. Each imaging modality has its own unique principles, advantages, and limitations, thus necessitating a multimodal approach for a comprehensive disease understanding of the disease process. To enhance diagnostic precision, physicians frequently integrate data from multiple imaging modalities, driving research advancements in multimodal imaging technology research. Methods In this study, hematoporphyrin-poly (lactic acid) (HP-PLLA) polymer was prepared via ring-opening polymerization and thoroughly characterized using FT-IR, 1H-NMR, XRD, and TGA. HP-PLLA based nanoparticles encapsulating perfluoropentane (PFP) and salicylic acid were prepared via emulsion-solvent evaporation. Zeta potential and mean diameter were assessed using DLS and TEM. Biocompatibility was evaluated via cell migration, hemolysis, and cytotoxicity assays. Ultrasonic imaging was performed with a dedicated apparatus, while CEST MRI was conducted using a 7.0 T animal scanner. Results We designed and prepared a novel dual-mode nanoimaging probe SA/PFP@HP-PLLA NPs. PFP enhanced US imaging, while salicylic acid bolstered CEST imaging. With an average size of 74.43 ± 1.12 nm, a polydispersity index of 0.175 ± 0.015, and a surface zeta potential of -64.1 ± 2.11 mV. These NPs exhibit excellent biocompatibility and stability. Both in vitro and in vivo experiments confirmed the SA/PFP@HP-PLLA NP's ability to improve tumor characterization and diagnostic precision. Conclusion The SA/PFP@HP-PLLA NPs demonstrate promising dual-modality imaging capabilities, indicating their potential for preclinical and clinical use as a contrast agent.
Collapse
Affiliation(s)
- Liqiong Ding
- Xianning Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| | - Fengnan Xu
- Xianning Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| | - Binhua Luo
- Xianning Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| | - Liyuan Cheng
- Xianning Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| | - Lingping Huang
- Department of Medical Ultrasound, Xianning Central Hospital, The First Affiliated Hospital of Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| | - Yanlong Jia
- Department of Radiology, Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang, Hubei Province, People’s Republic of China
| | - Jieqiong Ding
- Xianning Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, People’s Republic of China
| |
Collapse
|
3
|
Viswanathan M, Kurmi Y, Zu Z. A rapid method for phosphocreatine-weighted imaging in muscle using double saturation power-chemical exchange saturation transfer. NMR IN BIOMEDICINE 2024; 37:e5089. [PMID: 38114069 DOI: 10.1002/nbm.5089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 11/20/2023] [Accepted: 11/21/2023] [Indexed: 12/21/2023]
Abstract
Monitoring the variation in phosphocreatine (PCr) levels following exercise provides valuable insights into muscle function. Chemical exchange saturation transfer (CEST) has emerged as a sensitive method with which to measure PCr levels in muscle, surpassing conventional MR spectroscopy. However, existing approaches for quantifying PCr CEST signals rely on time-consuming fitting methods that require the acquisition of the entire or a section of the CEST Z-spectrum. Additionally, traditional fitting methods often necessitate clear CEST peaks, which may be challenging to obtain at low magnetic fields. This paper evaluated the application of a new model-free method using double saturation power (DSP), termed DSP-CEST, to estimate the PCr CEST signal in muscle. The DSP-CEST method requires the acquisition of only two or a few CEST signals at the PCr frequency offset with two different saturation powers, enabling rapid dynamic imaging. Additionally, the DSP-CEST approach inherently eliminates confounding signals, offering enhanced robustness compared with fitting methods. Furthermore, DSP-CEST does not demand clear CEST peaks, making it suitable for low-field applications. We evaluated the capability of DSP-CEST to enhance the specificity of PCr CEST imaging through simulations and experiments on muscle tissue phantoms at 4.7 T. Furthermore, we applied DSP-CEST to animal leg muscle both before and after euthanasia and observed successful reduction of confounding signals. The DSP-CEST signal still has contaminations from a residual magnetization transfer (MT) effect and an aromatic nuclear Overhauser enhancement effect, and thus only provides a PCr-weighted imaging. The residual MT effect can be reduced by a subtraction of DSP-CEST signals at 2.6 and 5 ppm. Results show that the residual MT-corrected DSP-CEST signal at 2.6 ppm has significant variation in postmortem tissues. By contrast, both the CEST signal at 2.6 ppm and a conventional Lorentzian difference analysis of CEST signal at 2.6 ppm demonstrate no significant variation in postmortem tissues.
Collapse
Affiliation(s)
- Malvika Viswanathan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Yashwant Kurmi
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
4
|
Zhao J, Wu G, Wu Q, Gong P, Kuang J, Zheng H, Sun PZ, Li Y, Wu Y. A Pilot Study of Ratiometric Creatine CEST MRI Assessment of Rabbit Skeletal Muscle Energy Metabolism at 3 T. J Magn Reson Imaging 2024; 59:201-208. [PMID: 37246769 DOI: 10.1002/jmri.28832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 05/17/2023] [Accepted: 05/17/2023] [Indexed: 05/30/2023] Open
Abstract
BACKGROUND pH MRI may provide useful information to evaluate metabolic disruption following ischemia. Radiofrequency amplitude-based creatine chemical exchange saturation transfer (CrCEST) ratiometric MRI is pH-sensitive, which could but has not been explored to examine muscle ischemia. PURPOSE To investigate skeletal muscle energy metabolism alterations with CrCEST ratiometric MRI. STUDY TYPE Prospective. ANIMAL MODEL Seven adult New Zealand rabbits with ipsilateral hindlimb muscle ischemia. FIELD STRENGTH/SEQUENCE 3 T/two MRI scans, including MRA and CEST imaging, were performed under two B1 amplitudes of 0.5 and 1.25 μT after 2 hours of hindlimb muscle ischemia and 1 hour of reperfusion recovery, respectively. ASSESSMENT CEST effects of two energy metabolites of creatine and phosphocreatine (PCrCEST) were resolved with the multipool Lorentzian fitting approach. The pixel-wise CrCEST ratio was quantified by calculating the ratio of the resolved CrCEST peaks under a B1 amplitude of 1.25 μT to those under 0.5 μT in the entire muscle. STATISTICAL TESTS One-way ANOVA and Pearson's correlation. P < 0.05 was considered statistically significant. RESULTS MRA images confirmed the blood flow loss and restoration in the ischemic hindlimb at the ischemia and recovery phases, respectively. Ischemic muscles exhibited a significant decrease of PCr at the ischemia (under both B1 amplitudes) and recovery phases (under B1 amplitude of 0.5 μT) and significantly increased CrCEST from normal tissues at both phases (under both B1 levels). Specifically, CrCEST decreased, and PCrCEST increased with the CrCEST ratio. Significantly strong correlations were observed among the CrCEST ratio, and CrCEST and PCrCEST under both B1 levels (r > 0.80). DATA CONCLUSION The CrCEST ratio altered substantially with muscle pathological states and was closely related to CEST effects of energy metabolites of Cr and PCr, suggesting that the pH-sensitive CrCEST ratiometric MRI is feasible to evaluate muscle injuries at the metabolic level. EVIDENCE LEVEL 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Jialei Zhao
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Gang Wu
- Department of Radiology, Tongji Hospital of Tongji College of Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Qiting Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Pengcheng Gong
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Junfeng Kuang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Ye Li
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| |
Collapse
|
5
|
Xu J, Chung JJ, Jin T. Chemical exchange saturation transfer imaging of creatine, phosphocreatine, and protein arginine residue in tissues. NMR IN BIOMEDICINE 2023; 36:e4671. [PMID: 34978371 PMCID: PMC9250548 DOI: 10.1002/nbm.4671] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/06/2021] [Accepted: 12/02/2021] [Indexed: 05/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI has become a promising technique to assay target proteins and metabolites through their exchangeable protons, noninvasively. The ubiquity of creatine (Cr) and phosphocreatine (PCr) due to their pivotal roles in energy homeostasis through the creatine phosphate pathway has made them prime targets for CEST in the diagnosis and monitoring of disease pathologies, particularly in tissues heavily dependent on the maintenance of rich energy reserves. Guanidinium CEST from protein arginine residues (i.e. arginine CEST) can also provide information about the protein profile in tissue. However, numerous obfuscating factors stand as obstacles to the specificity of arginine, Cr, and PCr imaging through CEST, such as semisolid magnetization transfer, fast chemical exchanges such as primary amines, and the effects of nuclear Overhauser enhancement from aromatic and amide protons. In this review, the specific exchange properties of protein arginine residues, Cr, and PCr, along with their validation, are discussed, including the considerations necessary to target and tune their signal effects through CEST imaging. Additionally, strategies that have been employed to enhance the specificity of these exchanges in CEST imaging are described, along with how they have opened up possible applications of protein arginine residues, Cr and PCr CEST imaging in the study and diagnosis of pathology. A clear understanding of the capabilities and caveats of using CEST to image these vital metabolites and mitigation strategies is crucial to expanding the possibilities of this promising technology.
Collapse
Affiliation(s)
- Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Julius Juhyun Chung
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
6
|
Vassallo G, Garello F, Aime S, Terreno E, Delli Castelli D. 31P ParaCEST: 31P MRI-CEST Imaging Based on the Formation of a Ternary Adduct between Inorganic Phosphate and Eu-DO3A. Inorg Chem 2022; 61:19663-19667. [PMID: 36445702 PMCID: PMC9946289 DOI: 10.1021/acs.inorgchem.2c03329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Indexed: 11/30/2022]
Abstract
Development of the field of magnetic resonance imaging (MRI) chemical exchange saturation transfer (CEST) contrast agents is hampered by the limited sensitivity of the technique. In water, the high proton concentration allows for an enormous amplification of the exchanging proton pool. However, the 1H CEST in water implies that the number of nuclear spins of the CEST-generating species has to be in the millimolar range. The use of nuclei other than a proton allows exploitation of signals different from that of water, thus lowering the concentration of the exchanging pool as the source of the CEST effect. In this work, we report on the detection of a 31P signal from endogenous inorganic phosphate (Pifree) as the source of CEST contrast by promoting its exchange with the Pi bound to the exogenous complex 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (Pibound). The herein-reported results demonstrate that this approach can improve the detectability threshold by 3 orders of magnitude with respect to the conventional 1H CEST detection (considered per single proton). This achievement reflects the decrease of the bulk concentration of the detected signal from 111.2 M (water) to 10 mM (Pi). This method paves the way to a number of biological studies and clinically translatable applications, herein addressed with a proof-of-concept in the field of cellular imaging.
Collapse
Affiliation(s)
- Giulia Vassallo
- Department
of Molecular Biotechnology and Health Science, University of Turin, Via Nizza 52, 10126Turin, Italy
| | - Francesca Garello
- Department
of Molecular Biotechnology and Health Science, University of Turin, Via Nizza 52, 10126Turin, Italy
| | - Silvio Aime
- IRCCS
SDN SynLab, Via E. Gianturco
113, 80143Napoli, Italy
| | - Enzo Terreno
- Department
of Molecular Biotechnology and Health Science, University of Turin, Via Nizza 52, 10126Turin, Italy
| | - Daniela Delli Castelli
- Department
of Molecular Biotechnology and Health Science, University of Turin, Via Nizza 52, 10126Turin, Italy
| |
Collapse
|
7
|
Wu ST, Chen PC, Tseng YH, Chen TH, Wang YJ, Tsai ZL, Lin EC. Assessment of cellular responses in three-dimensional cell cultures through chemical exchange saturation transfer and 1 H MRS. NMR IN BIOMEDICINE 2022; 35:e4757. [PMID: 35510307 DOI: 10.1002/nbm.4757] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 04/21/2022] [Accepted: 05/02/2022] [Indexed: 06/14/2023]
Abstract
Metabolic responses to physiological changes have been detected using chemical exchange saturation transfer (CEST) imaging in clinical settings. Similarly to other MRI techniques, the CEST technique was based originally on phantoms from buffer solutions and was then further developed through animal experiments. However, CEST imaging can capture certain dynamics of metabolism that solution phantoms cannot model. Cell culture phantoms can fill the gap between buffer phantoms and animal models. In this study, we used 1 H NMR and CEST in a B0 field of 9.4 T to investigate HEK293T cells from two-dimensional (2D) cultures, three-dimensional (3D) cultures, and 3D cultures seeded with cell spheroids. Two CEST dips were observed: the magnitude of the amine dip at 2.8 ppm increased during the incubation period, whereas the hydroxyl dip at 1.2 ppm remained approximately the same or modestly increased. We also observed a CEST dip at 2.8 ppm from the 2D culture responding dramatically to doxorubicin treatment. By cross-validating with pH values and the concentrations of amine and hydroxyl protons extracted through 1 H NMR, we observed that they did not correspond to an increase in the amine pool. We believe that the denaturation or degradation of proteins from the fetal bovine serum increased the size of the amine pool. Although 3D culture conditions can be further improved, our study suggests that 3D cultures have the potential to bridge studies of solution phantoms and those on animals.
Collapse
Affiliation(s)
- Ssu-Ting Wu
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Pin-Chen Chen
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Yu-Hsien Tseng
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Ting-Hao Chen
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Yi-Jiun Wang
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Zong-Lin Tsai
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
| | - Eugene C Lin
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chiayi, Taiwan
- Center for Nano Bio-detection, National Chung Cheng University, Chiayi, Taiwan
| |
Collapse
|