1
|
Schram J, Parrilla M, Sleegers N, Slosse A, Van Durme F, van Nuijs ALN, De Wael K. Electrochemical classification of benzodiazepines: A comprehensive approach combining insights from voltammetry and liquid chromatography - mass spectrometry. Talanta 2024; 279:126623. [PMID: 39084042 DOI: 10.1016/j.talanta.2024.126623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Revised: 07/23/2024] [Accepted: 07/26/2024] [Indexed: 08/02/2024]
Abstract
The growing non-medical use of benzodiazepines (BZs) has led to the emergence of counterfeit BZ pills and new psycho-active substances (NPS) in the BZ class on the illicit market. Comprehensive analytical methods for BZ identification are required to allow law enforcement, first aid responders and drug-checking services to analyze a variety of sample types and contents to make timely decisions on the spot. In this work, the electrochemical behavior of diazepam (DZ), clonazepam (CZ) and alprazolam (AP) is studied on graphite screen-printed electrodes, both with and without dissolved oxygen in the solution, to link their redox signals to their chemical structure. After elucidation of their reduction mechanisms using liquid chromatography coupled to high-resolution mass spectrometry, three structural classes (Class 1, Class 2 and Class 3) were defined, each with different redox centers and electrochemical behavior. Subsequently, 22 confiscated pills containing 14 different BZs were correctly assigned to these three structural classes, with the deoxygenated conditions displaying the highest class selectivity. Finally, the three classes were successfully detected after being spiked into five alcoholic beverages in the context of drug-facilitated sexual assault. For analysis in red wine, which complicated the analysis by interfering with Class 1, a dual test strategy in pH 2 and pH 7 was proposed for accurate detection. Its rapid measurements, broad scope and lack of interference from diluents or colors makes this method a promising approach for aiding various services in combating problematic BZ use.
Collapse
Affiliation(s)
- Jonas Schram
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| | - Marc Parrilla
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| | - Nick Sleegers
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| | - Amorn Slosse
- Drugs and Toxicology Department, National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120, Brussels, Belgium
| | - Filip Van Durme
- Drugs and Toxicology Department, National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120, Brussels, Belgium
| | | | - Karolien De Wael
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium.
| |
Collapse
|
2
|
Zhang T, Abdelhamid SA, Li D, Zhang H. A hydrogel-modified electrochemical biosensor for the rapid detection of ammonia‑nitrogen-resistant bacteria. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 932:172828. [PMID: 38692312 DOI: 10.1016/j.scitotenv.2024.172828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 04/03/2024] [Accepted: 04/25/2024] [Indexed: 05/03/2024]
Abstract
Ammonia‑nitrogen wastewater is one of the main pollutants in the current environment. Rapid detection of microorganisms resistant to ammonia‑nitrogen provides a basis for bioremediation of ammonia‑nitrogen contaminated sites. This study uses electrochemical analysis for efficiently detecting of ammonia-resistant bacteria, utilizing a commercially available, low-cost screen-printed electrode (SPE) modified with agarose-based hydrogel (gel) or graphene oxide (GO). At the same time, the study employed electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) to monitor bacterial growth, revealing Escherichia coli (E. coli) inhibition upon ammonia‑nitrogen addition, while Raoultella terrigena (RN1) and Pseudomonas (RN2) exhibit tolerance. The method provides sensitivity results in <45 min, which is significantly faster than traditional methods. RN1 and RN2 exhibit promising ammonia‑nitrogen removal rates, reaching up to 81 % and 92 %, respectively. This study aimed to develop an effective electrochemical method for rapidly detecting the sensitivity of microorganisms to ammonia‑nitrogen. The method offers advantages such as high speed, efficiency, and cost-effectiveness, potentially providing valuable microbial resources for mitigating ammonia nitrogen wastewater pollution.
Collapse
Affiliation(s)
- Ting Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China
| | | | - Defeng Li
- State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, China.
| | - Houjin Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China.
| |
Collapse
|
3
|
Soliman SS, Mahmoud AM, Elghobashy MR, Zaazaa HE, Sedik GA. Eco-friendly electrochemical sensor for determination of conscious sedating drug "midazolam'' based on Au-NPs@Silica modified carbon paste electrode. Talanta 2024; 267:125238. [PMID: 37774450 DOI: 10.1016/j.talanta.2023.125238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 08/09/2023] [Accepted: 09/22/2023] [Indexed: 10/01/2023]
Abstract
Benzodiazepines (BZDs) are a group of drugs prescribed for their sedating effect. Their misuse and addictive properties stipulate different authorities for developing simple, fast and accurate analytical methods for instantaneous detection. Differential pulse voltammetric technique (DPV) was utilized for the selective assay of midazolam hydrochloride (MDZ) in the pure, parenteral dosage forms and plasma samples. A chemically modified carbon paste electrode (CPE) was implemented during the study. The method depended on the electroreduction of MDZ on the surface of the electrode over a potential range of 0.0 V to -1.6 V. The electrode was fabricated using silica nanoparticles (Si-NPs) which were incorporated into the composition of the CPE and used to enhance the electrode performance. Then, to enhance the sensitivity of the method, a chronoamperometric modification step was applied for depositing gold nanoparticles (Au-NPs) on the carbon paste electrode surface. Modification with Au-NPs showed a higher reduction current peak for MDZ with well-defined peaks. Various parameters such as pH of the media and measurements scan rate were investigated and optimized to enhance the sensor sensitivity. The sensor showed a dynamic linear response over a concentration range of 4.0 × 10-7 M to 2.9 × 10-4 M of MDZ with a LOD of 2.24 × 10-8 M using 0.1 M acetate buffer (pH 5.6). The sensor was validated in accordance with the ICH guidelines regarding accuracy, precision and specificity for the selective assay of MDZ in the presence of excipients. A greenness evaluation was performed using three different assessment tools, namely, the "Green Analytical Procedure Index" (GAPI), the "Analytical Greenness metric" (AGREE) and the "Whiteness Analytical Chemistry tool" (WAC) using the RGB12 model.
Collapse
Affiliation(s)
- Shymaa S Soliman
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, October 6 City, Giza, 12858, Egypt
| | - Amr M Mahmoud
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt
| | - Mohamed R Elghobashy
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, October 6 City, Giza, 12858, Egypt; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt
| | - Hala E Zaazaa
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt
| | - Ghada A Sedik
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt.
| |
Collapse
|
4
|
Affiliation(s)
- David Love
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| | - Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
- 70113 Street, N.W., Suite 750, Washington, DC, 20005-3967, USA
| |
Collapse
|
5
|
A Comparative Study between Screen-Printed and Solid-Contact Electrodes for the Stability-Indicating Determination of Bromazepam. Molecules 2022; 27:molecules27217616. [DOI: 10.3390/molecules27217616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 10/29/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022] Open
Abstract
Stability-indicating methods are awesome tools to ensure the safety and efficacy of active pharmaceutical ingredients (APIs). An accurate comparative study involving the use of potentiometric sensors for the determination of bromazepam (BRZ) in the presence of its main product of degradation and impurity was performed by the fabrication of two membrane electrodes. A screen-printed electrode (SPE) and a solid-contact glassy carbon electrode (SCE) were fabricated and their performance optimized. The fabricated sensors showed a linear electrochemical response in the concentration range 1.0 × 10−6 M to 1.0 × 10−2 M. The electrodes exhibited Nernstian slopes of 59.70 mV/decade and 58.10 mV/decade for the BRZ-SPE and BRZ-SCE membrane electrodes, respectively. The electrochemical performance was greatly affected by the medium pH. They showed an almost ideal electrochemical performance between pH 3.0 and pH 6.0. The fabricated membranes were applied successfully for the quantification of BRZ in the presence of up to 90% of its degradation product. Moreover, a successful application of the fabricated electrodes was performed for the sensitive and selective quantification of BRZ in its tablet form without any pretreatment procedure.
Collapse
|
6
|
Potentiometric Determination of Moxifloxacin by Solid-Contact ISEs in Wastewater Effluents. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10040146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
In recent years, the use of ion-selective membranes in the sensing and assessment of environmental contaminants has become a critical goal. Using sodium tetraphenylborate (TPB) and phosphotungstic acid (PTA) as ion-pairing agents, two sensitive and selective sensors were manufactured to evaluate the electrochemical response of moxifloxacin hydrochloride (MOX). The optimal electrochemical behavior was attained by fine-tuning all assay parameters. The manufactured membranes’ performance was optimal in a pH range from 1.0 to 5.0 with a linearity between 1 × 10−6 M and 1 × 10−2 M. The MOX–TPB and MOX–PTA membrane electrodes have Nernstian slopes of 59.2 ± 0.60 mV/decade and 58.4 ± 0.50 mV/decade, respectively. The proposed method was used to determine MOX in its pure form as well as real pharmaceutical wastewater effluents. The fabricated electrodes were effectively applied for the sensitive and selective determination of MOX in actual wastewater effluents without the need for any pre-treatment processes.
Collapse
|