1
|
Thomas M, Greaves RF, Tingay DG, Loh TP, Ignjatovic V, Newall F, Oeum M, Tran MTC, Rajapaksa AE. Current and emerging technologies for the timely screening and diagnosis of neonatal jaundice. Crit Rev Clin Lab Sci 2022; 59:332-352. [PMID: 35188857 DOI: 10.1080/10408363.2022.2038074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Neonatal jaundice is one of the most common clinical conditions affecting newborns. For most newborns, jaundice is harmless, however, a proportion of newborns develops severe neonatal jaundice requiring therapeutic interventions, accentuating the need to have reliable and accurate screening tools for timely recognition across different health settings. The gold standard method in diagnosing jaundice involves a blood test and requires specialized hospital-based laboratory instruments. Despite technological advancements in point-of-care laboratory medicine, there is limited accessibility of the specialized devices and sample stability in geographically remote areas. Lack of suitable testing options leads to delays in timely diagnosis and treatment of clinically significant jaundice in developed and developing countries alike. There has been an ever-increasing need for a low-cost, simple to use screening technology to improve timely diagnosis and management of neonatal jaundice. Consequently, several point-of-care (POC) devices have been developed to address this concern. This paper aims to review the literature, focusing on emerging technologies in the screening and diagnosing of neonatal jaundice. We report on the challenges associated with the existing screening tools, followed by an overview of emerging sensors currently in pre-clinical development and the emerging POC devices in clinical trials to advance the screening of neonatal jaundice. The benefits offered by emerging POC devices include their ease of use, low cost, and the accessibility of rapid response test results. However, further clinical trials are required to overcome the current limitations of the emerging POC's before their implementation in clinical settings. Hence, the need for a simple to use, low-cost POC jaundice detection technology for newborns remains an unsolved challenge globally.
Collapse
Affiliation(s)
- Mercy Thomas
- New Vaccines, Murdoch Children's Research Institute, Melbourne, Australia.,Department of Paediatrics, University of Melbourne, Melbourne, Australia.,Newborn Research Centre, Royal Women's Hospital, Melbourne, Australia.,Department of Nursing, Royal Children's Hospital, Melbourne, Australia
| | - Ronda F Greaves
- Department of Paediatrics, University of Melbourne, Melbourne, Australia.,School of Health and Biomedical Sciences, RMIT University, Melbourne, Australia.,Victorian Clinical Genetics Services, Melbourne, Australia.,International Federation of Clinical Chemistry and Laboratory Medicine-Emerging Technologies Division (C-ETPLM), Milan, Italy
| | - David G Tingay
- Department of Paediatrics, University of Melbourne, Melbourne, Australia.,Newborn Research Centre, Royal Women's Hospital, Melbourne, Australia.,Neonatal Research, Murdoch Children's Research Institute, Melbourne, Australia.,Department of Neonatology, Royal Children's Hospital, Melbourne, Australia
| | - Tze Ping Loh
- International Federation of Clinical Chemistry and Laboratory Medicine-Emerging Technologies Division (C-ETPLM), Milan, Italy.,Department of Laboratory Medicine, National University Hospital, Singapore, Singapore
| | - Vera Ignjatovic
- Department of Paediatrics, University of Melbourne, Melbourne, Australia.,Hematology, Murdoch Children's Research Institute, Melbourne, Australia
| | - Fiona Newall
- Department of Paediatrics, University of Melbourne, Melbourne, Australia.,Department of Nursing, Royal Children's Hospital, Melbourne, Australia
| | - Michelle Oeum
- New Vaccines, Murdoch Children's Research Institute, Melbourne, Australia
| | - Mai Thi Chi Tran
- International Federation of Clinical Chemistry and Laboratory Medicine-Emerging Technologies Division (C-ETPLM), Milan, Italy.,National Children's Hospital, Hanoi, Vietnam.,Hanoi Medical University, Hanoi, Vietnam
| | - Anushi E Rajapaksa
- New Vaccines, Murdoch Children's Research Institute, Melbourne, Australia.,Department of Paediatrics, University of Melbourne, Melbourne, Australia.,Newborn Research Centre, Royal Women's Hospital, Melbourne, Australia.,Think Project Global, Melbourne, Australia
| |
Collapse
|
2
|
Point-of-care detection assay based on biomarker-imprinted polymer for different cancers: a state-of-the-art review. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04085-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
3
|
Mustafa YL, Keirouz A, Leese HS. Molecularly Imprinted Polymers in Diagnostics: Accessing Analytes in Biofluids. J Mater Chem B 2022; 10:7418-7449. [DOI: 10.1039/d2tb00703g] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Bio-applied molecularly imprinted polymers (MIPs) are biomimetic materials with tailor-made synthetic recognition sites, mimicking biological counterparts known for their sensitive and selective analyte detection. MIPs, specifically designed for biomarker analysis...
Collapse
|
4
|
Parnianchi F, Kashanian S, Nazari M, Santoro C, Bollella P, Varmira K. Highly selective and sensitive molecularly imprinting electrochemical sensing platform for bilirubin detection in saliva. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106367] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
5
|
Xia M, Sui Y, Guo Y, Zhang Y. Aggregation-induced emission enhancement of gold nanoclusters in metal-organic frameworks for highly sensitive fluorescent detection of bilirubin. Analyst 2021; 146:904-910. [PMID: 33355318 DOI: 10.1039/d0an02076a] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
A fluorescence analysis method based on gold nanocluster (AuNC) and metal-organic framework (MOF) composite materials (AuNCs@ZIF-8) was established for highly sensitive detection of bilirubin (BR). First, AuNCs@ZIF-8 was successfully obtained by co-precipitation and displayed an aggregation-induced emission enhancement by the confinement effect of the MOFs (i.e., ZIF-8). The product showed approximately 7.0 times enhancement in the quantum yield and longer fluorescence lifetime from 2.29 μs to 11.51 μs compared with AuNCs. When BR combined with the metal node Zn2+ of ZIF-8, the skeleton of the composite was destroyed, leading to a great decrease in the fluorescence intensity by the transformation of the AuNCs from the aggregated state to dispersed state. The linear range for the detection of BR was 0.1-5.0 μM, with the limit of detection (LOD) of 0.07 μM (S/N = 3). The AuNCs@ZIF-8 exhibited a selective response toward BR within 5 min and detected BR in human serum. The long-wavelength emission by AuNCs avoided the interference of the complex biomatrix background fluorescence, indicating their great application prospects for clinical diagnosis.
Collapse
Affiliation(s)
- Mengfan Xia
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China. and Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China
| | - Yucun Sui
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China. and Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China
| | - Ying Guo
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China. and Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China
| | - Yaodong Zhang
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China. and Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, China
| |
Collapse
|
6
|
Bhatia M, Kaur S, Sood SK, Behal V. Internet of things-inspired healthcare system for urine-based diabetes prediction. Artif Intell Med 2020; 107:101913. [DOI: 10.1016/j.artmed.2020.101913] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 05/30/2020] [Accepted: 06/12/2020] [Indexed: 02/05/2023]
|
7
|
Pirzada M, Altintas Z. Nanomaterials for Healthcare Biosensing Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5311. [PMID: 31810313 PMCID: PMC6928990 DOI: 10.3390/s19235311] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 11/22/2019] [Accepted: 11/27/2019] [Indexed: 12/12/2022]
Abstract
In recent years, an increasing number of nanomaterials have been explored for their applications in biomedical diagnostics, making their applications in healthcare biosensing a rapidly evolving field. Nanomaterials introduce versatility to the sensing platforms and may even allow mobility between different detection mechanisms. The prospect of a combination of different nanomaterials allows an exploitation of their synergistic additive and novel properties for sensor development. This paper covers more than 290 research works since 2015, elaborating the diverse roles played by various nanomaterials in the biosensing field. Hence, we provide a comprehensive review of the healthcare sensing applications of nanomaterials, covering carbon allotrope-based, inorganic, and organic nanomaterials. These sensing systems are able to detect a wide variety of clinically relevant molecules, like nucleic acids, viruses, bacteria, cancer antigens, pharmaceuticals and narcotic drugs, toxins, contaminants, as well as entire cells in various sensing media, ranging from buffers to more complex environments such as urine, blood or sputum. Thus, the latest advancements reviewed in this paper hold tremendous potential for the application of nanomaterials in the early screening of diseases and point-of-care testing.
Collapse
Affiliation(s)
| | - Zeynep Altintas
- Technical University of Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany;
| |
Collapse
|
8
|
The influence of cross-linking agent onto adsorption properties, release behavior and cytotoxicity of doxorubicin-imprinted microparticles. Colloids Surf B Biointerfaces 2019; 182:110379. [PMID: 31351269 DOI: 10.1016/j.colsurfb.2019.110379] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/31/2019] [Accepted: 07/17/2019] [Indexed: 02/08/2023]
Abstract
Molecularly imprinted polymers (MIPs) are synthetic polymers that possess cavities selective towards their molecular templates and have found many applications in separation science, drug delivery, and catalysis. Here, we report the synthesis of doxorubicin-imprinted microparticles cross-linked with two different compounds (ethylene glycol dimethacrylate or trimethylolpropane trimethacrylate) and examination of their physicochemical properties. During the synthesis methacrylic acid was used as functional monomer and 2-hydroxyethyl methacrylate was added into polymerization mixture to increase hydrophilicity of the obtained materials and therefore improve interactions with aqueous release medium. The influence of initial concentration and contact time onto doxorubicin adsorption by obtained MIPs microparticles have been investigated. The microparticles obtained using ethylene glycol dimethacrylate as a cross-linker showed 3 times higher adsorption properties towards doxorubicin, than the ones obtained using trimethylolpropane trimethacrylate cross-linker. The release kinetics of doxorubicin from drug-loaded MIPs microparticles has been proven to be dependent upon cross-linker used and pH of the release medium. For drug-loaded MIPs microparticles obtained using both cross-linkers the IC50 values measured for cancer cell were comparable to the ones measured for pure doxorubicin, whereas the cytotoxicity towards normal HDF cell lines was lower.
Collapse
|
9
|
Size of Heparin-Imprinted Nanoparticles Reflects the Matched Interactions with the Target Molecule. SENSORS 2019; 19:s19102415. [PMID: 31137824 PMCID: PMC6566179 DOI: 10.3390/s19102415] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 05/09/2019] [Accepted: 05/23/2019] [Indexed: 11/24/2022]
Abstract
It has been shown that the faradic current at an electrode grafted with molecularly imprinted polymer (MIP) is sensitive to the specific target molecule used as the template. This phenomenon is applicable to sensors with very high selectivity, but the sensing mechanism is still a black box. We investigated the size sensitivity of nanoparticles of molecularly imprinted polymers (MIP-NPs) to a specific interaction for determination of the mechanism of the gate effect and its feasibility for new applications. Nanoparticles of poly(methacryloxy ethyl trimethylammonium chloride-co-acrylamide-co-methylenebisacrylamide) imprinted with heparin immobilized on glass beads were synthesized. The diameter of the MIP-NPs of heparin was increased by the presence of the heparin template but was insensitive to chondroitin sulfate C (CSC), the analogue of heparin. The high selectivity of the MIP-NPs was consistent with the selectivity of electrodes grafted with a heparin-imprinted polymer in our previous studies. The quartz crystal microbalance probes immobilizing heparin or CSC were sensitive to MIP-NPs, which indicates that the binding ability of MIP-NP does not discriminate between the template and other glycosaminoglycans. These results indicate that the size of the MIP-NP is sensitive to the matched binding with the template through the imprinted cavity.
Collapse
|
10
|
Polyvinyl Acetate Film-Based Quartz Crystal Microbalance for the Detection of Benzene, Toluene, and Xylene Vapors in Air. CHEMOSENSORS 2019. [DOI: 10.3390/chemosensors7020020] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Vapors of volatile organic compounds such as benzene, toluene, and xylene (BTX) may cause health concerns. The sensitive detection of these compounds in air remains challenging. In this study, we reported on modification of the Quartz Crystal Microbalance (QCM) sensing chip using polyvinyl acetate (PVAc) film as active coating for the analysis of BTX vapors. The PVAc film was deposited on the QCM sensing chip surface by a spin coating technique. The morphology of the PVAc films was confirmed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The sensitivities of PVAc based QCM system for benzene, toluene, and xylene analyses were 0.018, 0.041, and 0.081 Hz/ppm, respectively. The high sensitivity of the proposed QCM system for analysis of BTX vapors is believed to be due to the effective interaction between the PVAc film and BTX molecules. The analyte vapor pressure appears to also affect the sensitivity. These data show that the prepared QCM sensor has a low time constant, good reproducibility, and excellent stability. It offers an alternative to the developed methods for detection of BTX and possibly other aromatic hydrocarbons in the air.
Collapse
|
11
|
Saylan Y, Akgönüllü S, Yavuz H, Ünal S, Denizli A. Molecularly Imprinted Polymer Based Sensors for Medical Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E1279. [PMID: 30871280 PMCID: PMC6472044 DOI: 10.3390/s19061279] [Citation(s) in RCA: 113] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 03/04/2019] [Accepted: 03/10/2019] [Indexed: 02/08/2023]
Abstract
Sensors have been extensively used owing to multiple advantages, including exceptional sensing performance, user-friendly operation, fast response, high sensitivity and specificity, portability, and real-time analysis. In recent years, efforts in sensor realm have expanded promptly, and it has already presented a broad range of applications in the fields of medical, pharmaceutical and environmental applications, food safety, and homeland security. In particular, molecularly imprinted polymer based sensors have created a fascinating horizon for surface modification techniques by forming specific recognition cavities for template molecules in the polymeric matrix. This method ensures a broad range of versatility to imprint a variety of biomolecules with different size, three dimensional structure, physical and chemical features. In contrast to complex and time-consuming laboratory surface modification methods, molecular imprinting offers a rapid, sensitive, inexpensive, easy-to-use, and highly selective approaches for sensing, and especially for the applications of diagnosis, screening, and theranostics. Due to its physical and chemical robustness, high stability, low-cost, and reusability features, molecularly imprinted polymer based sensors have become very attractive modalities for such applications with a sensitivity of minute structural changes in the structure of biomolecules. This review aims at discussing the principle of molecular imprinting method, the integration of molecularly imprinted polymers with sensing tools, the recent advances and strategies in molecular imprinting methodologies, their applications in medical, and future outlook on this concept.
Collapse
Affiliation(s)
- Yeşeren Saylan
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey.
| | - Semra Akgönüllü
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey.
| | - Handan Yavuz
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey.
| | - Serhat Ünal
- Department of Infectious Disease and Clinical Microbiology, Hacettepe University, Ankara 06230, Turkey.
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey.
| |
Collapse
|
12
|
Ngashangva L, Bachu V, Goswami P. Development of new methods for determination of bilirubin. J Pharm Biomed Anal 2018; 162:272-285. [PMID: 30273817 DOI: 10.1016/j.jpba.2018.09.034] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 09/11/2018] [Accepted: 09/16/2018] [Indexed: 02/06/2023]
Abstract
The ever-increasing demand for a sensitive, rapid and reliable method for determination of serum bilirubin level has been inciting the interest of the researchers to develop new methods for both laboratory set up and point of care applications. These efforts embrace measurement of different forms of bilirubin, such as, unconjugated (free and albumin bound) bilirubin, conjugated (direct) bilirubin, and total (both conjugated and unconjugated) bilirubin in the serum that may provide critical information useful for diagnosis of many diseases and metabolic disorders. Herein, an effort has been made to provide a broad overview on the subject starting from the conventional spectroscopy based analytical methods widely practiced in the laboratory setup along with the sophisticated instrument based sensitive methods suitable for determination of different forms of bilirubin to various portable low cost systems applicable in point of care (POC) settings. In all these discussions emphasis is given on the novel methods and techniques bearing potential to measure the bilirubin level in biological samples reliably with less technical complexity and cost. We expect that this review will serve as a ready reference for the researchers and clinical professionals working on the subject and allied fields.
Collapse
Affiliation(s)
- Lightson Ngashangva
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| | - Vinay Bachu
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| | - Pranab Goswami
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India.
| |
Collapse
|
13
|
Giorgini A, Avino S, Malara P, De Natale P, Gagliardi G. Opto-mechanical oscillator in a nanoliter droplet. OPTICS LETTERS 2018; 43:3473-3476. [PMID: 30067688 DOI: 10.1364/ol.43.003473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 06/19/2018] [Indexed: 06/08/2023]
Abstract
Droplets are very simple physical systems, whereby surface tension shapes liquids into ideal opto-mechanical devices. This has recently enabled low-viscosity liquid samples to serve as miniature acoustic resonators harnessing optical generation of bulk vibrations, capillaries, or surface waves. Uniquely, a simple room-temperature pendant droplet can be activated as a hypersound-laser emitter when illuminated by a free-space, low-power visible laser thanks to stimulated Brillouin scattering of optical and acoustic whispering-gallery modes. Here, we demonstrate continuous operation of a liquid polymer opto-mechanical resonator and characterize its quality factor and long-term frequency stability. Our results point to the feasibility of all-liquid micro-mechanical oscillators working in the 50-100 MHz range. The stimulated generation of high-quality surface waves on nanoliter droplets gives momentum to new optical schemes for characterization of material viscous-elastic properties, laboratory investigation of atmospheric phenomena, and mass sensing for direct analysis of biological fluids based on ultrasound-hypersound coherent generation and detection.
Collapse
|
14
|
Yang W, Xia J, Zhou G, Jiang D, Li Q. Sensitive detection of free bilirubin in blood serum using β-diketone modified europium-doped yttrium oxide nanosheets as a luminescent sensor. RSC Adv 2018; 8:17854-17859. [PMID: 35542082 PMCID: PMC9080476 DOI: 10.1039/c8ra02817f] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 05/08/2018] [Indexed: 11/26/2022] Open
Abstract
Free bilirubin, when present in excess in the human body, can cause a multitude of diseases and disorders and even be fatal; hence, detecting it is of paramount importance. Herein, we report a luminescence quenching-based non-enzymatic method for the convenient, reliable, and rapid detection of free bilirubin in blood serum samples using sensing films (nanosheets/PS, nanosheets-tta/PS, and nanosheets-dbt/PS) as luminescent sensors. The luminescence intensity of the sensing films is linearly related to the free bilirubin concentration. Nanosheets-tta/PS demonstrated excellent sensing properties for the sensitive and reliable detection of free bilirubin in the range of 0.0-60.0 μM with a correlation coefficient of 0.9915, as compared to nanosheets/PS or nanosheets-dbt/PS. The limit of detection for the determination of free bilirubin was 41 nM. This method can be used to design a sensor-based test spot as a medical detection device for the visual detection of free bilirubin.
Collapse
Affiliation(s)
- Wei Yang
- Department of Chemistry, East China Normal University Shanghai 200062 P. R. China
| | - Jinfeng Xia
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Guohong Zhou
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Danyu Jiang
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Qiang Li
- Department of Chemistry, East China Normal University Shanghai 200062 P. R. China
| |
Collapse
|
15
|
Saylan Y, Yilmaz F, Özgür E, Derazshamshir A, Yavuz H, Denizli A. Molecular Imprinting of Macromolecules for Sensor Applications. SENSORS 2017; 17:s17040898. [PMID: 28422082 PMCID: PMC5426548 DOI: 10.3390/s17040898] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 04/07/2017] [Accepted: 04/07/2017] [Indexed: 02/06/2023]
Abstract
Molecular recognition has an important role in numerous living systems. One of the most important molecular recognition methods is molecular imprinting, which allows host compounds to recognize and detect several molecules rapidly, sensitively and selectively. Compared to natural systems, molecular imprinting methods have some important features such as low cost, robustness, high recognition ability and long term durability which allows molecularly imprinted polymers to be used in various biotechnological applications, such as chromatography, drug delivery, nanotechnology, and sensor technology. Sensors are important tools because of their ability to figure out a potentially large number of analytical difficulties in various areas with different macromolecular targets. Proteins, enzymes, nucleic acids, antibodies, viruses and cells are defined as macromolecules that have wide range of functions are very important. Thus, macromolecules detection has gained great attention in concerning the improvement in most of the studies. The applications of macromolecule imprinted sensors will have a spacious exploration according to the low cost, high specificity and stability. In this review, macromolecules for molecularly imprinted sensor applications are structured according to the definition of molecular imprinting methods, developments in macromolecular imprinting methods, macromolecular imprinted sensors, and conclusions and future perspectives. This chapter follows the latter strategies and focuses on the applications of macromolecular imprinted sensors. This allows discussion on how sensor strategy is brought to solve the macromolecules imprinting.
Collapse
Affiliation(s)
- Yeşeren Saylan
- Department of Chemistry, Division of Biochemistry, Hacettepe University, 06800 Ankara, Turkey.
| | - Fatma Yilmaz
- Department of Chemistry Technology, Abant Izzet Baysal University, 14900 Bolu, Turkey.
| | - Erdoğan Özgür
- Department of Chemistry, Division of Biochemistry, Hacettepe University, 06800 Ankara, Turkey.
| | - Ali Derazshamshir
- Department of Chemistry, Division of Biochemistry, Hacettepe University, 06800 Ankara, Turkey.
| | - Handan Yavuz
- Department of Chemistry, Division of Biochemistry, Hacettepe University, 06800 Ankara, Turkey.
| | - Adil Denizli
- Department of Chemistry, Division of Biochemistry, Hacettepe University, 06800 Ankara, Turkey.
| |
Collapse
|
16
|
Selvolini G, Marrazza G. MIP-Based Sensors: Promising New Tools for Cancer Biomarker Determination. SENSORS 2017; 17:s17040718. [PMID: 28353669 PMCID: PMC5421678 DOI: 10.3390/s17040718] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 03/24/2017] [Accepted: 03/27/2017] [Indexed: 12/12/2022]
Abstract
Detecting cancer disease at an early stage is one of the most important issues for increasing the survival rate of patients. Cancer biomarker detection helps to provide a diagnosis before the disease becomes incurable in later stages. Biomarkers can also be used to evaluate the progression of therapies and surgery treatments. In recent years, molecularly imprinted polymer (MIP) based sensors have been intensely investigated as promising analytical devices in several fields, including clinical analysis, offering desired portability, fast response, specificity, and low cost. The aim of this review is to provide readers with an overview on recent important achievements in MIP-based sensors coupled to various transducers (e.g., electrochemical, optical, and piezoelectric) for the determination of cancer biomarkers by selected publications from 2012 to 2016.
Collapse
Affiliation(s)
- Giulia Selvolini
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, Sesto Fiorentino 50019, Italy.
| | - Giovanna Marrazza
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, Sesto Fiorentino 50019, Italy.
| |
Collapse
|
17
|
Emir Diltemiz S, Keçili R, Ersöz A, Say R. Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors. SENSORS 2017; 17:s17030454. [PMID: 28245588 PMCID: PMC5375740 DOI: 10.3390/s17030454] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 02/20/2017] [Accepted: 02/21/2017] [Indexed: 01/29/2023]
Abstract
Molecularly imprinted polymers (MIPs) as artificial antibodies have received considerable scientific attention in the past years in the field of (bio)sensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values, etc.). On the other hand, the Quartz Crystal Microbalance (QCM) is an analytical tool based on the measurement of small mass changes on the sensor surface. QCM sensors are practical and convenient monitoring tools because of their specificity, sensitivity, high accuracy, stability and reproducibility. QCM devices are highly suitable for converting the recognition process achieved using MIP-based memories into a sensor signal. Therefore, the combination of a QCM and MIPs as synthetic receptors enhances the sensitivity through MIP process-based multiplexed binding sites using size, 3D-shape and chemical function having molecular memories of the prepared sensor system toward the target compound to be detected. This review aims to highlight and summarize the recent progress and studies in the field of (bio)sensor systems based on QCMs combined with molecular imprinting technology.
Collapse
Affiliation(s)
- Sibel Emir Diltemiz
- Chemistry Department, Faculty of Science, Anadolu University, 26470 Eskisehir, Turkey.
| | - Rüstem Keçili
- Department of Medical Services and Techniques, Yunus Emre Vocational School of Health Services, Anadolu University, 26470 Eskisehir, Turkey.
| | - Arzu Ersöz
- Chemistry Department, Faculty of Science, Anadolu University, 26470 Eskisehir, Turkey.
| | - Rıdvan Say
- Chemistry Department, Faculty of Science, Anadolu University, 26470 Eskisehir, Turkey.
- Bionkit Co. Ltd., 26470 Eskisehir, Turkey.
| |
Collapse
|