1
|
Mintz Hemed N, Leal-Ortiz S, Zhao ET, Melosh NA. On-Demand, Reversible, Ultrasensitive Polymer Membrane Based on Molecular Imprinting Polymer. ACS NANO 2023; 17:5632-5643. [PMID: 36913954 PMCID: PMC10062346 DOI: 10.1021/acsnano.2c11618] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
The development of in vivo, longitudinal, real-time monitoring devices is an essential step toward continuous, precision health monitoring. Molecularly imprinted polymers (MIPs) are popular sensor capture agents that are more robust than antibodies and have been used for sensors, drug delivery, affinity separations, assays, and solid-phase extraction. However, MIP sensors are typically limited to one-time use due to their high binding affinity (>107 M-1) and slow-release kinetics (<10-4 μM/sec). To overcome this challenge, current research has focused on stimuli-responsive MIPs (SR-MIPs), which undergo a conformational change induced by external stimuli to reverse molecular binding, requiring additional chemicals or outside stimuli. Here, we demonstrate fully reversible MIP sensors based on electrostatic repulsion. Once the target analyte is bound within a thin film MIP on an electrode, a small electrical potential successfully releases the bound molecules, enabling repeated, accurate measurements. We demonstrate an electrostatically refreshed dopamine sensor with a 760 pM limit of detection, linear response profile, and accuracy even after 30 sensing-release cycles. These sensors could repeatedly detect <1 nM dopamine released from PC-12 cells in vitro, demonstrating they can longitudinally measure low concentrations in complex biological environments without clogging. Our work provides a simple and effective strategy for enhancing the use of MIPs-based biosensors for all charged molecules in continuous, real-time health monitoring and other sensing applications.
Collapse
Affiliation(s)
- Nofar Mintz Hemed
- Department
of Materials Science and Engineering, Stanford
University, Stanford, California 94305, United States
| | - Sergio Leal-Ortiz
- Department
of Psychiatry and Behavioral Sciences, Stanford
University, Stanford, California 94304, United States
| | - Eric T. Zhao
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Nicholas A. Melosh
- Department
of Materials Science and Engineering, Stanford
University, Stanford, California 94305, United States
| |
Collapse
|
2
|
Advances on Hormones in Cosmetics: Illegal Addition Status, Sample Preparation, and Detection Technology. Molecules 2023; 28:molecules28041980. [PMID: 36838967 PMCID: PMC9959700 DOI: 10.3390/molecules28041980] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 02/11/2023] [Accepted: 02/16/2023] [Indexed: 02/22/2023] Open
Abstract
Owing to the rapid development of the cosmetic industry, cosmetic safety has become the focus of consumers' attention. However, in order to achieve the desired effects in the short term, the illegal addition of hormones in cosmetics has emerged frequently, which could induce skin problems and even skin cancer after long-term use. Therefore, it is of great significance to master the illegal addition in cosmetics and effectively detect the hormones that may exist in cosmetics. In this review, we analyze the illegally added hormone types, detection values, and cosmetic types, as well as discuss the hormone risks in cosmetics for human beings, according to the data in unqualified cosmetics in China from 2017 to 2022. Results showed that although the frequency of adding hormones in cosmetics has declined, hormones are still the main prohibited substances in illegal cosmetics, especially facial masks. Because of the complex composition and the low concentration of hormones in cosmetics, it is necessary to combine efficient sample preparation technology with instrumental analysis. In order to give the readers a comprehensive overview of hormone analytical technologies in cosmetics, we summarize the advanced sample preparation techniques and commonly used detection techniques of hormones in cosmetics in the last decade (2012-2022). We found that ultrasound-assisted extraction, solid phase extraction, and microextraction coupled with chromatographic analysis are still the most widely used analytical technologies for hormones in cosmetics. Through the investigation of market status, the summary of sample pretreatment and detection technologies, as well as the discussion of their development trends in the future, our purpose is to provide a reference for the supervision of illegal hormone residues in cosmetics.
Collapse
|
3
|
Suzaei FM, Daryanavard SM, Abdel-Rehim A, Bassyouni F, Abdel-Rehim M. Recent molecularly imprinted polymers applications in bioanalysis. CHEMICAL PAPERS 2023; 77:619-655. [PMID: 36213319 PMCID: PMC9524737 DOI: 10.1007/s11696-022-02488-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 09/10/2022] [Indexed: 11/18/2022]
Abstract
Molecular imprinted polymers (MIPs) as extraordinary compounds with unique features have presented a wide range of applications and benefits to researchers. In particular when used as a sorbent in sample preparation methods for the analysis of biological samples and complex matrices. Its application in the extraction of medicinal species has attracted much attention and a growing interest. This review focus on articles and research that deals with the application of MIPs in the analysis of components such as biomarkers, drugs, hormones, blockers and inhibitors, especially in biological matrices. The studies based on MIP applications in bioanalysis and the deployment of MIPs in high-throughput settings and optimization of extraction methods are presented. A review of more than 200 articles and research works clearly shows that the superiority of MIP techniques lies in high accuracy, reproducibility, sensitivity, speed and cost effectiveness which make them suitable for clinical usage. Furthermore, this review present MIP-based extraction techniques and MIP-biosensors which are categorized on their classes based on common properties of target components. Extraction methods, studied sample matrices, target analytes, analytical techniques and their results for each study are described. Investigations indicate satisfactory results using MIP-based bioanalysis. According to the increasing number of studies on method development over the last decade, the use of MIPs in bioanalysis is growing and will further expand the scope of MIP applications for less studied samples and analytes.
Collapse
Affiliation(s)
- Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition & Standard of Qeshm (MHCS Company), Qeshm Island, Iran
| | - Seyed Mosayeb Daryanavard
- grid.444744.30000 0004 0382 4371Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- grid.5335.00000000121885934Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Fatma Bassyouni
- grid.419725.c0000 0001 2151 8157Chemistry of Natural and Microbial Products Department, Pharmaceutical industry Research Division, National Research Centre, Cairo, 12622 Egypt
| | - Mohamed Abdel-Rehim
- grid.5037.10000000121581746Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden and Med. Solutions, Stockholm, Sweden
| |
Collapse
|
4
|
Kubo T, Yamamoto S, Watabe Y, Tanigawa T, Nakajima D, Otsuka K. Selective Separation of Thyroid-Hormone-Receptor-Binding Substances Using Molecularly Imprinted Polymers. ACS APPLIED BIO MATERIALS 2022; 5:5210-5217. [PMID: 36260820 DOI: 10.1021/acsabm.2c00618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
To date, an identification protocol for endocrine disruptors that bind to the thyroid hormone receptor (TR) has not been established. A method for screening and identifying TR-binding substances is highly required due to the existence of unknown TR-binding substances from the environment. Here, we conceived a chromatographic method using a molecularly imprinted polymer (MIP) to create a novel screening protocol for the endocrine disruptors. A receptor-imitating MIP was prepared using N-acetylthyroxine (AcetylT4) and 4-vinylpyridine as a pseudo-template and a functional monomer, respectively, based on the existing molecular recognition mechanism of the TR. The receptor-imitating MIP provided molecular recognition ability for all the TR-binding substances that were employed in this study. The prepared MIPs were packed into a high-performance liquid chromatography column for the simultaneous analysis of TR-binding and non-binding substances. The former was strongly retained, while the latter was not. The presence or absence of TR-binding/non-binding activity resulted in successful dichotomous separation. Additionally, the surface imprinting technique was applied to improve the separation performance of the MIP packing material. MIP-coated uniformly sized silica-based particles of 5 μm were successfully prepared, and the MIP-coated silica column enabled more efficient dichotomous separation of TR-binding and non-binding substances.
Collapse
Affiliation(s)
- Takuya Kubo
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto615-8510, Japan
| | - Shuhei Yamamoto
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto615-8510, Japan
| | - Yoshiyuki Watabe
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto615-8510, Japan.,Research Center, Shimadzu General Service, Inc, 1, Nishinokyo, Kuwabara-cho, Nakagyo-ku, Kyoto604-8511, Japan
| | - Tetsuya Tanigawa
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto615-8510, Japan
| | - Daisuke Nakajima
- Health and Environmental Risk Division, National Institute for Environmental Studies (NIES), 16-2 Onogawa, Tsukuba-shi, Ibaraki-ken305-8506Japan
| | - Koji Otsuka
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto615-8510, Japan
| |
Collapse
|
5
|
Modification of Cotton Fabric with Molecularly Imprinted Polymer-Coated Carbon Dots as a Sensor for 17 α-methyltestosterone. Molecules 2022; 27:molecules27217257. [DOI: 10.3390/molecules27217257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/14/2022] [Accepted: 10/20/2022] [Indexed: 11/16/2022] Open
Abstract
Molecularly imprinted polymers@ethylenediamine-modified carbon dots grafted on cotton fabrics (MIPs@EDA-CDs/CF) and smartphone-based fluorescence image analysis were proposed and used for the first time for the detection of 17 α-methyltestosterone (MT). The EDA-CDs were synthesized and grafted on cotton fabric before coating with the MIPs. The MIPs were synthesized using the MT as a template molecule, methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a cross-linker, and azobisisobutyronitrile (AIBN) as an initiator. The MIPs@EDA-CDs/CF were characterized using FTIR, SEM-EDS, and RGB fluorescence imaging. The fluorescence images were also taken using a smartphone and the ImageJ program was used for RGB measurement. The Δ red intensity was linearly proportional to MT concentration in the range of 100 to 1000 μg/L (R2 = 0.999) with a detection limit of 44.4 μg/L and quantification limit of 134 μg/L. The MIPs@EDA-CDs/CF could be stored at 4 °C for a few weeks and could be reused twice. The proposed method could apply for the specific determination of MT in water and sediment samples along with satisfactory recoveries of 96–104% and an acceptable relative standard deviation of 1–6% at the ppb level.
Collapse
|
6
|
Tavana B, Chen A. Determination of Drugs in Clinical Trials: Current Status and Outlook. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22041592. [PMID: 35214505 PMCID: PMC8875021 DOI: 10.3390/s22041592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Revised: 02/03/2022] [Accepted: 02/14/2022] [Indexed: 05/30/2023]
Abstract
All pharmaceutical drugs, vaccines, cosmetic products, and many medical breakthroughs must first be approved through clinical research and trials before advancing to standard practice or entering the marketplace. Clinical trials are sets of tests that are required to determine the safety and efficacy of pharmaceutical compounds, drugs, and treatments. There is one pre-phase and four main clinical phase requirements that every drug must pass to obtain final approval. Analytical techniques play a unique role in clinical trials for measuring the concentrations of pharmaceutical compounds in biological matrices and monitoring the conditions of patients (or volunteers) during various clinical phases. This review focuses on recent analytical methods that are employed to determine the concentrations of drugs and medications in biological matrices, including whole blood, plasma, urine, and breast milk. Four primary analytical techniques (extraction, spectroscopy, chromatography, and electrochemical) are discussed, and their advantages and limitations are assessed. Subsequent to a survey of evidence and results, it is clear that microelectromechanical system (MEMS) based electrochemical sensor and biosensor technologies exhibit several notable advantages over other analytical methods, and their future prospects are discussed.
Collapse
Affiliation(s)
| | - Aicheng Chen
- Correspondence: ; Tel.: +1-519-8244120 (ext. 54764); Fax: +1-519-7661499
| |
Collapse
|
7
|
Carasek E, Morés L, Huelsmann RD. Disposable pipette extraction: A critical review of concepts, applications, and directions. Anal Chim Acta 2022; 1192:339383. [DOI: 10.1016/j.aca.2021.339383] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 12/15/2021] [Accepted: 12/16/2021] [Indexed: 01/14/2023]
|