Alhorani Q, Alkhybari E, Rawashdeh M, Sabarudin A, Latiff RA, Al-Ibraheem A, Vinjamuri S, Mohamad M. Revising and exploring the variations in methodologies for establishing the diagnostic reference levels for paediatric PET/CT imaging. Nucl Med Commun 2023; 44:937-943. [PMID: 37615527 DOI: 10.1097/mnm.0000000000001748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
PET-computed tomography (PET/CT) is a hybrid imaging technique that combines anatomical and functional information; to investigate primary cancers, stage tumours, and track treatment response in paediatric oncology patients. However, there is debate in the literature about whether PET/CT could increase the risk of cancer in children, as the machine is utilizing two types of radiation, and paediatric patients have faster cell division and longer life expectancy. Therefore, it is essential to minimize radiation exposure by justifying and optimizing PET/CT examinations and ensure an acceptable image quality. Establishing diagnostic reference levels (DRLs) is a crucial quantitative indicator and effective tool to optimize paediatric imaging procedures. This review aimed to distinguish and acknowledge variations among published DRLs for paediatric patients in PET/CT procedures. A search of relevant articles was conducted using databases, that is, Embase, Scopus, Web of Science, and Medline, using the keywords: PET-computed tomography, computed tomography, PET, radiopharmaceutical, DRL, and their synonyms. Only English and full-text articles were included, with no limitations on the publication year. After the screening, four articles were selected, and the review reveals different DRL approaches for paediatric patients undergoing PET/CT, with primary variations observed in patient selection criteria, reporting of radiation dose values, and PET/CT equipment. The study suggests that future DRL methods for paediatric patients should prioritize data collection in accordance with international guidelines to better understand PET/CT dose discrepancies while also striving to optimize radiation doses without compromising the quality of PET/CT images.
Collapse
Affiliation(s)
- Qays Alhorani
- Center for Diagnostics, Therapeutics and Investigative, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Essam Alkhybari
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
| | - Mohammad Rawashdeh
- Radiologic Technology Program, Applied Medical Sciences College, Jordan University of Science and Technology, Irbid
| | - Akmal Sabarudin
- Center for Diagnostics, Therapeutics and Investigative, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Rukiah A Latiff
- Center for Diagnostics, Therapeutics and Investigative, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Akram Al-Ibraheem
- Department of Nuclear Medicine, King Hussein Cancer Centre, Amman, Jordan
| | - Sobhan Vinjamuri
- Department of Nuclear Medicine, Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK
| | - Mazlyfarina Mohamad
- Center for Diagnostics, Therapeutics and Investigative, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| |
Collapse
|
2
|
Reproducibility and Repeatability of Coronary Computed Tomography Angiography (CCTA) Image Segmentation in Detecting Atherosclerosis: A Radiomics Study. Diagnostics (Basel) 2022; 12:diagnostics12082007. [PMID: 36010355 PMCID: PMC9406887 DOI: 10.3390/diagnostics12082007] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/23/2022] Open
Abstract
Atherosclerosis is known as the leading factor in heart disease with the highest mortality rate among the Malaysian population. Usually, the gold standard for diagnosing atherosclerosis is by using the coronary computed tomography angiography (CCTA) technique to look for plaque within the coronary artery. However, qualitative diagnosis for noncalcified atherosclerosis is vulnerable to false-positive diagnoses, as well as inconsistent reporting between observers. In this study, we assess the reproducibility and repeatability of segmenting atherosclerotic lesions manually and semiautomatically in CCTA images to identify the most appropriate CCTA image segmentation method for radiomics analysis to quantitatively extract the atherosclerotic lesion. Thirty (30) CCTA images were taken retrospectively from the radiology image database of Hospital Canselor Tuanku Muhriz (HCTM), Kuala Lumpur, Malaysia. We extract 11,700 radiomics features which include the first-order, second-order and shape features from 180 times of image segmentation. The interest vessels were segmentized manually and semiautomatically using LIFEx (Version 7.0.15, Institut Curie, Orsay, France) software by two independent radiology experts, focusing on three main coronary blood vessels. As a result, manual segmentation with a soft-tissuewindowing setting yielded higher repeatability as compared to semiautomatic segmentation with a significant intraclass correlation coefficient (intra-CC) 0.961 for thefirst-order and shape features; intra-CC of 0.924 for thesecond-order features with p < 0.001. Meanwhile, the semiautomatic segmentation has higher reproducibility as compared to manual segmentation with significant interclass correlation coefficient (inter-CC) of 0.920 (first-order features) and a good interclass correlation coefficient of 0.839 for the second-order features with p < 0.001. The first-order, shape order and second-order features for both manual and semiautomatic segmentation have an excellent percentage of reproducibility and repeatability (intra-CC > 0.9). In conclusion, semi-automated segmentation is recommended for inter-observer study while manual segmentation with soft tissue-windowing can be used for single observer study.
Collapse
|
4
|
Kamal I, Razak HRA, Abdul Karim MK, Mashohor S, Liew JYC, Low YJ, Zaaba NA, Norkhairunnisa M, Rafi NASM. Mechanical and Imaging Properties of a Clinical-Grade Kidney Phantom Based on Polydimethylsiloxane and Elastomer. Polymers (Basel) 2022; 14:polym14030535. [PMID: 35160523 PMCID: PMC8840541 DOI: 10.3390/polym14030535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/08/2021] [Accepted: 12/10/2021] [Indexed: 02/01/2023] Open
Abstract
Medical imaging phantoms are considered critical in mimicking the properties of human tissue for calibration, training, surgical planning, and simulation purposes. Hence, the stability and accuracy of the imaging phantom play a significant role in diagnostic imaging. This study aimed to evaluate the influence of hydrogen silicone (HS) and water (H2O) on the compression strength, radiation attenuation properties, and computed tomography (CT) number of the blended Polydimethylsiloxane (PDMS) samples, and to verify the best material to simulate kidney tissue. Four samples with different compositions were studied, including samples S1, S2, S3, and S4, which consisted of PDMS 100%, HS/PDMS 20:80, H2O/PDMS 20:80, and HS/H2O/PDMS 20:40:40, respectively. The stability of the samples was assessed using compression testing, and the attenuation properties of sample S2 were evaluated. The effective atomic number of S2 showed a similar pattern to the human kidney tissue at 1.50 × 10−1 to 1 MeV. With the use of a 120 kVp X-ray beam, the CT number quantified for S2, as well measured 40 HU, and had the highest contrast-to-noise ratio (CNR) value. Therefore, the S2 sample formulation exhibited the potential to mimic the human kidney, as it has a similar dynamic and is higher in terms of stability as a medical phantom.
Collapse
Affiliation(s)
- Izdihar Kamal
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Hairil Rashmizal Abdul Razak
- Department of Radiology, Faculty of Medicine and Health Sciences, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Muhammad Khalis Abdul Karim
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
- Correspondence: ; Tel.: +60-192140612
| | - Syamsiah Mashohor
- Department of Computer and Communication Systems, Faculty of Engineering, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Josephine Ying Chyi Liew
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Yiin Jian Low
- Department of Physics, Faculty of Science, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia; (J.Y.C.L.); (Y.J.L.)
| | - Nur Atiqah Zaaba
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
- Diagnostic Imaging Services, KPJ Seremban Specialist Hospital, Lot 6219&6220, Jalan Toman 1 Kemayan Square, Seremban 70200, Negeri Sembilan, Malaysia
| | - Mazlan Norkhairunnisa
- Institute of Advanced Technology, University of Putra Malaysia, Seri Kembangan 43400, Selangor, Malaysia;
| | - Nur Athirah Syima Mohd Rafi
- Department of Medical Imaging, School of Health Sciences, KPJ Healthcare University College, Nilai 71800, Negeri Sembilan, Malaysia; (I.K.); (N.A.Z.); (N.A.S.M.R.)
| |
Collapse
|
5
|
Kayun Z, Abdul Karim MK, Harun HH, Shaari AH, Mahmud R, Hamid HA, Sabarudin A, Chew MT. Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109694] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|