1
|
Gao S, Peng C, Wang G, Deng C, Zhang Z, Liu X. Cartilage T2 mapping-based radiomics in knee osteoarthritis research: Status, progress and future outlook. Eur J Radiol 2024; 181:111826. [PMID: 39522425 DOI: 10.1016/j.ejrad.2024.111826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 10/09/2024] [Accepted: 11/06/2024] [Indexed: 11/16/2024]
Abstract
Osteoarthritis (OA) affects more than 500 millions people worldwide and places an enormous economic and medical burden on patients and healthcare systems. The knee is the most commonly affected joint. However, there is no effective early diagnostic method for OA. The main pathological feature of OA is cartilage degeneration. Owing to the poor regenerative ability of chondrocytes, early detection of OA and prompt intervention are extremely important. The T2 relaxation time indicates changes in cartilage composition and responds to alterations in the early cartilage matrix. T2 mapping does not require contrast agents or special equipment, so it is widely used. Radiomics analysis methods are used to construct diagnostic or predictive models based on information extracted from clinical images. Owing to the development of artificial intelligence methods, radiomics has made excellent progress in segmentation and model construction. In this review, we summarize the progress of T2 mapping radiomics research methods in terms of T2 map acquisition, image postprocessing, and OA diagnosis or predictive model construction.
Collapse
Affiliation(s)
- Shi Gao
- Department of Rehabilitation, Shengjing Hospital of China Medical University, Shenyang, China
| | - Chengbao Peng
- Platform Engineering Research Center, Neusoft Research Institute of Healthcare Technology, Shenyang, Liaoning Province, China
| | - Guan Wang
- Platform Engineering Research Center, Neusoft Research Institute of Healthcare Technology, Shenyang, Liaoning Province, China
| | - Chunbo Deng
- Department of Orthopedics, Central Hospital of Shenyang Medical College, Shenyang, China
| | - Zhan Zhang
- Department of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, China
| | - Xueyong Liu
- Department of Rehabilitation, Shengjing Hospital of China Medical University, Shenyang, China.
| |
Collapse
|
2
|
Bolan PJ, Saunders SL, Kay K, Gross M, Akcakaya M, Metzger GJ. Improved quantitative parameter estimation for prostate T 2 relaxometry using convolutional neural networks. MAGMA (NEW YORK, N.Y.) 2024; 37:721-735. [PMID: 39042205 PMCID: PMC11417079 DOI: 10.1007/s10334-024-01186-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/01/2024] [Accepted: 07/02/2024] [Indexed: 07/24/2024]
Abstract
OBJECTIVE Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.
Collapse
Affiliation(s)
- Patrick J Bolan
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA.
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
| | - Sara L Saunders
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Kendrick Kay
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Mitchell Gross
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Gregory J Metzger
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
3
|
Ehmig J, Engel G, Lotz J, Lehmann W, Taheri S, Schilling AF, Seif Amir Hosseini A, Panahi B. MR-Imaging in Osteoarthritis: Current Standard of Practice and Future Outlook. Diagnostics (Basel) 2023; 13:2586. [PMID: 37568949 PMCID: PMC10417111 DOI: 10.3390/diagnostics13152586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 07/30/2023] [Accepted: 08/01/2023] [Indexed: 08/13/2023] Open
Abstract
Osteoarthritis (OA) is a common degenerative joint disease that affects millions of people worldwide. Magnetic resonance imaging (MRI) has emerged as a powerful tool for the evaluation and monitoring of OA due to its ability to visualize soft tissues and bone with high resolution. This review aims to provide an overview of the current state of MRI in OA, with a special focus on the knee, including protocol recommendations for clinical and research settings. Furthermore, new developments in the field of musculoskeletal MRI are highlighted in this review. These include compositional MRI techniques, such as T2 mapping and T1rho imaging, which can provide additional important information about the biochemical composition of cartilage and other joint tissues. In addition, this review discusses semiquantitative joint assessment based on MRI findings, which is a widely used method for evaluating OA severity and progression in the knee. We analyze the most common scoring methods and discuss potential benefits. Techniques to reduce acquisition times and the potential impact of deep learning in MR imaging for OA are also discussed, as these technological advances may impact clinical routine in the future.
Collapse
Affiliation(s)
- Jonathan Ehmig
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, 37075 Göttingen, Germany; (J.E.); (G.E.)
| | - Günther Engel
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, 37075 Göttingen, Germany; (J.E.); (G.E.)
| | - Joachim Lotz
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, 37075 Göttingen, Germany; (J.E.); (G.E.)
| | - Wolfgang Lehmann
- Clinic of Trauma, Orthopedics and Reconstructive Surgery, Georg-August-University of Göttingen, 37075 Göttingen, Germany
| | - Shahed Taheri
- Clinic of Trauma, Orthopedics and Reconstructive Surgery, Georg-August-University of Göttingen, 37075 Göttingen, Germany
| | - Arndt F. Schilling
- Clinic of Trauma, Orthopedics and Reconstructive Surgery, Georg-August-University of Göttingen, 37075 Göttingen, Germany
| | - Ali Seif Amir Hosseini
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, 37075 Göttingen, Germany; (J.E.); (G.E.)
| | - Babak Panahi
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, 37075 Göttingen, Germany; (J.E.); (G.E.)
| |
Collapse
|
4
|
Bolan PJ, Saunders SL, Kay K, Gross M, Akcakaya M, Metzger GJ. Improved Quantitative Parameter Estimation for Prostate T2 Relaxometry using Convolutional Neural Networks. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.01.11.23284194. [PMID: 36711813 PMCID: PMC9882442 DOI: 10.1101/2023.01.11.23284194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
This work seeks to evaluate multiple methods for quantitative parameter estimation from standard T2 mapping acquisitions in the prostate. The T2 estimation performance of methods based on neural networks (NN) was quantitatively compared to that of conventional curve fitting techniques. Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Ten combinations of different NN architectures, training strategies, and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst all the methods. On in vivo data, this best-performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.
Collapse
Affiliation(s)
- Patrick J Bolan
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| | - Sara L Saunders
- Department of Biomedical Engineering, University of Minnesota, Minneapolis MN
| | - Kendrick Kay
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| | - Mitchell Gross
- Department of Biomedical Engineering, University of Minnesota, Minneapolis MN
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis MN
| | - Gregory J Metzger
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| |
Collapse
|
5
|
Evaluation of Sodium Relaxation Times and Concentrations in the Achilles Tendon Using MRI. Int J Mol Sci 2022; 23:ijms231810890. [PMID: 36142810 PMCID: PMC9501448 DOI: 10.3390/ijms231810890] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 09/10/2022] [Accepted: 09/13/2022] [Indexed: 11/21/2022] Open
Abstract
Sodium magnetic resonance imaging (MRI) can be used to evaluate the change in the proteoglycan content in Achilles tendons (ATs) of patients with different AT pathologies by measuring the 23Na signal-to-noise ratio (SNR). As 23Na SNR alone is difficult to compare between different studies, because of the high influence of hardware configurations and sequence settings on the SNR, we further set out to measure the apparent tissue sodium content (aTSC) in the AT as a better comparable parameter. Ten healthy controls and one patient with tendinopathy in the AT were examined using a clinical 3 Tesla (T) MRI scanner in conjunction with a dual tuned 1H/23Na surface coil to measure 23Na SNR and aTSC in their ATs. 23Na T1 and T2* of the AT were also measured for three controls to correct for different relaxation behavior. The results were as follows: 23Na SNR = 11.7 ± 2.2, aTSC = 82.2 ± 13.9 mM, 23Na T1 = 20.4 ± 2.4 ms, 23Na T2s* = 1.4 ± 0.4 ms, and 23Na T2l* = 13.9 ± 0.8 ms for the whole AT of healthy controls with significant regional differences. These are the first reported aTSCs and 23Na relaxation times for the AT using sodium MRI and may serve for future comparability in different studies regarding examinations of diseased ATs with sodium MRI.
Collapse
|
6
|
Lorentzian-Corrected Apparent Exchange-Dependent Relaxation (LAREX) Ω-Plot Analysis-An Adaptation for qCEST in a Multi-Pool System: Comprehensive In Silico, In Situ, and In Vivo Studies. Int J Mol Sci 2022; 23:ijms23136920. [PMID: 35805925 PMCID: PMC9266897 DOI: 10.3390/ijms23136920] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/05/2022] [Accepted: 06/20/2022] [Indexed: 12/14/2022] Open
Abstract
Based on in silico, in situ, and in vivo studies, this study aims to develop a new method for the quantitative chemical exchange saturation transfer (qCEST) technique considering multi-pool systems. To this end, we extended the state-of-the-art apparent exchange-dependent relaxation (AREX) method with a Lorentzian correction (LAREX). We then validated this new method with in situ and in vivo experiments on human intervertebral discs (IVDs) using the Kendall-Tau correlation coefficient. In the in silico experiments, we observed significant deviations of the AREX method as a function of the underlying exchange rate (kba) and fractional concentration (fb) compared to the ground truth due to the influence of other exchange pools. In comparison to AREX, the LAREX-based Ω-plot approach yielded a substantial improvement. In the subsequent in situ and in vivo experiments on human IVDs, no correlation to the histological reference standard or Pfirrmann classification could be found for the fb (in situ: τ = −0.17 p = 0.51; in vivo: τ = 0.13 p = 0.30) and kba (in situ: τ = 0.042 p = 0.87; in vivo: τ = −0.26 p = 0.04) of Glycosaminoglycan (GAG) with AREX. In contrast, the influence of interfering pools could be corrected by LAREX, and a moderate to strong correlation was observed for the fractional concentration of GAG for both in situ (τ = −0.71 p = 0.005) and in vivo (τ = −0.49 p < 0.001) experiments. The study presented here is the first to introduce a new qCEST method that enables qCEST imaging in systems with multiple proton pools.
Collapse
|