1
|
Iranzo S, Belda-Lois JM, Martinez-de-Juan JL, Prats-Boluda G. Assessment of Muscle Coordination Changes Caused by the Use of an Occupational Passive Lumbar Exoskeleton in Laboratory Conditions. SENSORS (BASEL, SWITZERLAND) 2023; 23:9631. [PMID: 38139478 PMCID: PMC10747114 DOI: 10.3390/s23249631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/29/2023] [Accepted: 12/02/2023] [Indexed: 12/24/2023]
Abstract
The introduction of exoskeletons in industry has focused on improving worker safety. Exoskeletons have the objective of decreasing the risk of injury or fatigue when performing physically demanding tasks. Exoskeletons' effect on the muscles is one of the most common focuses of their assessment. The present study aimed to analyze the muscle interactions generated during load-handling tasks in laboratory conditions with and without a passive lumbar exoskeleton. The electromyographic data of the muscles involved in the task were recorded from twelve participants performing load-handling tasks. The correlation coefficient, coherence coefficient, mutual information, and multivariate sample entropy were calculated to determine if there were significant differences in muscle interactions between the two test conditions. The results showed that muscle coordination was affected by the use of the exoskeleton. In some cases, the exoskeleton prevented changes in muscle coordination throughout the execution of the task, suggesting a more stable strategy. Additionally, according to the directed Granger causality, a trend of increasing bottom-up activation was found throughout the task when the participant was not using the exoskeleton. Among the different variables analyzed for coordination, the most sensitive to changes was the multivariate sample entropy.
Collapse
Affiliation(s)
- Sofía Iranzo
- Instituto de Biomecánica de Valencia, Universitat Politècnica de València, 46022 Valencia, Spain; (S.I.); (J.-M.B.-L.)
| | - Juan-Manuel Belda-Lois
- Instituto de Biomecánica de Valencia, Universitat Politècnica de València, 46022 Valencia, Spain; (S.I.); (J.-M.B.-L.)
| | - Jose Luis Martinez-de-Juan
- Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Gema Prats-Boluda
- Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, 46022 Valencia, Spain;
| |
Collapse
|
2
|
Torres A, Estrada-Petrocelli L. Influence of the Fuzzy Function on the Estimation of the Fuzzy Sample Entropy with Fixed Tolerance Values for the Evaluation of Surface EMG Muscle Activity. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083599 DOI: 10.1109/embc40787.2023.10339974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Fixed sample entropy (fSampEn) is a technique that has demonstrated superior performance to other amplitude estimators for assessing respiratory muscle electromyographic activity. This technique is based on the calculation of sample entropy (SampEn) using fixed tolerance thresholds. Fuzzy entropy (FuzzyEn) introduces an improvement to the SampEn algorithm based on the use of a fuzzy measure to evaluate the similarity between vectors. However, several fuzzy functions have been used to calculate the FuzzyEn, and not all of them allow an effective comparison with the SampEn calculation parameters. In the present work, an analysis of the different fuzzy functions previously used has been carried out and a new sigmoid fuzzy function for the calculation of FuzzyEn with fixed tolerance thresholds (fFuzzyEn) has been proposed. The results show that the proposed fuzzy function outperformed both fSampEn and previously proposed FuzzyEn-based algorithms. These results suggest that fFuzzyEn could improve the assessment of muscle activity providing potentially useful diagnostic information.Clinical Relevance- This sets out the appropriate use of the fuzzy function for the estimation of the fuzzy sample entropy with fixed tolerance thresholds (fFuzzyEn). The use of fFuzzyEn could improve methods for detecting the onset and offset of respiratory electromyographic (EMG) signals, as well as the assessment of EMG activation level.
Collapse
|
3
|
Promsri A, Bangkomdet K, Jindatham I, Jenchang T. Leg Dominance—Surface Stability Interaction: Effects on Postural Control Assessed by Smartphone-Based Accelerometry. Sports (Basel) 2023; 11:sports11040075. [PMID: 37104149 PMCID: PMC10145104 DOI: 10.3390/sports11040075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 03/19/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023] Open
Abstract
The preferential use of one leg over another in performing lower-limb motor tasks (i.e., leg dominance) is considered to be one of the internal risk factors for sports-related lower-limb injuries. The current study aimed to investigate the effects of leg dominance on postural control during unipedal balancing on three different support surfaces with increasing levels of instability: a firm surface, a foam pad, and a multiaxial balance board. In addition, the interaction effect between leg dominance and surface stability was also tested. To this end, a tri-axial accelerometer-based smartphone sensor was placed over the lumbar spine (L5) of 22 young adults (21.5 ± 0.6 years) to record postural accelerations. Sample entropy (SampEn) was applied to acceleration data as a measure of postural sway regularity (i.e., postural control complexity). The results show that leg dominance (p < 0.001) and interaction (p < 0.001) effects emerge in all acceleration directions. Specifically, balancing on the dominant (kicking) leg shows more irregular postural acceleration fluctuations (high SampEn), reflecting a higher postural control efficiency or automaticity than balancing on the non-dominant leg. However, the interaction effects suggest that unipedal balancing training on unstable surfaces is recommended to reduce interlimb differences in neuromuscular control for injury prevention and rehabilitation.
Collapse
Affiliation(s)
- Arunee Promsri
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
- Unit of Excellence in Neuromechanics, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
- Correspondence: ; Tel.: +66-54-466-666 (ext. 3817)
| | - Kotchakorn Bangkomdet
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| | - Issariya Jindatham
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| | - Thananya Jenchang
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| |
Collapse
|
4
|
Gu X, Zhao X, Mao Z, Shi Y, Xu M, Cai M, Xie F. Effect of different anesthetic dose of pentobarbital on respiratory activity in rabbits. Comput Biol Med 2022; 145:105501. [DOI: 10.1016/j.compbiomed.2022.105501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 03/04/2022] [Accepted: 04/04/2022] [Indexed: 11/16/2022]
|
5
|
Postural Control and Adaptation Strategy of Young Adults on Unstable Surface. Motor Control 2022; 27:179-193. [PMID: 36216337 DOI: 10.1123/mc.2021-0138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 07/06/2022] [Accepted: 08/10/2022] [Indexed: 11/11/2022]
Abstract
Balance control is essential for postural adjustment in physical activities. This study investigates the behavior of human postural control and the coordination and adaptation strategy of hip, knee, and ankle when standing on an unstable surface. Twenty participants were recruited. Four different conditions were investigated: a quiet bipedal stance with eyes open and eyes closed, and standing on an unstable surface with eyes open and eyes closed. Other than the joint angle, the standard body sway measures, such as sway area and sway velocity, were computed. A nonlinear time series measure, that is, sample entropy, was used to determine the regularity of the time series and body adaptability to change and perturbation. The results show that the body sway increases as the difficulty increases. This study also confirms the coordination of the hip, knee, and ankle to maintain body balance on the unstable surface by decreasing the joint angle and adopting a lower posture. Even though the individual joint has lower sample entropy value and is deemed to be rigid and less adaptive to perturbation, the postural control exhibits higher sample entropy value, particularly in the anterior–posterior direction, and has the ability to stabilize the body by manipulating the joints simultaneously. These outcomes suggest that an unstable surface not only challenges the human postural control, but also reduces the hip, knee, and ankle adaptability to perturbation, thus making it a great tool to train body balance.
Collapse
|
6
|
Estrada-Petrocelli L, Lozano-Garcia M, Jane R, Torres A. Assessment of the Non-linear Response of the fSampEn on Simulated EMG Signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5582-5585. [PMID: 34892389 DOI: 10.1109/embc46164.2021.9629476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Fixed sample entropy (fSampEn) is a promising technique for the analysis of respiratory electromyographic (EMG) signals. Its use has shown outperformance of amplitude-based estimators such as the root mean square (RMS) in the evaluation of respiratory EMG signals with cardiac noise and a high correlation with respiratory signals, allowing changes in respiratory muscle activity to be tracked. However, the relationship between the fSampEn response to a given muscle activation has not been investigated. The aim of this study was to analyze the nature of the fSampEn measurements that are produced as the EMG activity increases linearly. Simulated EMG signals were generated and increased linearly. The effect of the parameters r and the size of the moving window N of the fSampEn were evaluated and compared with those obtained using the RMS. The RMS showed a linear trend throughout the study. A non-linear, sigmoidal-like behavior was found when analyzing the EMG signals using the fSampEn. The lower the values of r, the higher the non-linearity observed in the fSampEn results. Greater moving windows reduced the variation produced by too small values of r.Clinical Relevance- Understanding the inherent non-linear relationship produced when using the fSampEn in EMG recordings will contribute to the improvement of the respiratory muscle activation assessment at different levels of respiratory effort in patients with respiratory conditions, particularly during the inspiratory phase.
Collapse
|
7
|
Chou EF, Khine M, Lockhart T, Soangra R. Effects of ECG Data Length on Heart Rate Variability among Young Healthy Adults. SENSORS (BASEL, SWITZERLAND) 2021; 21:6286. [PMID: 34577492 PMCID: PMC8472063 DOI: 10.3390/s21186286] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 09/02/2021] [Accepted: 09/14/2021] [Indexed: 12/25/2022]
Abstract
The relationship between the robustness of HRV derived by linear and nonlinear methods to the required minimum data lengths has yet to be well understood. The normal electrocardiography (ECG) data of 14 healthy volunteers were applied to 34 HRV measures using various data lengths, and compared with the most prolonged (2000 R peaks or 750 s) by using the Mann-Whitney U test, to determine the 0.05 level of significance. We found that SDNN, RMSSD, pNN50, normalized LF, the ratio of LF and HF, and SD1 of the Poincaré plot could be adequately computed by small data size (60-100 R peaks). In addition, parameters of RQA did not show any significant differences among 60 and 750 s. However, longer data length (1000 R peaks) is recommended to calculate most other measures. The DFA and Lyapunov exponent might require an even longer data length to show robust results. Conclusions: Our work suggests the optimal minimum data sizes for different HRV measures which can potentially improve the efficiency and save the time and effort for both patients and medical care providers.
Collapse
Affiliation(s)
- En-Fan Chou
- Department of Biomedical Engineering, Henry Samueli School of Engineering, University of California at Irvine, Irvine, CA 92697, USA; (E.-F.C.); (M.K.)
| | - Michelle Khine
- Department of Biomedical Engineering, Henry Samueli School of Engineering, University of California at Irvine, Irvine, CA 92697, USA; (E.-F.C.); (M.K.)
| | - Thurmon Lockhart
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85281, USA;
| | - Rahul Soangra
- Department of Physical Therapy, Crean College of Health and Behavioral Sciences, Chapman University, Irvine, CA 92618, USA
- Department of Electrical and Computer Science Engineering, Fowler School of Engineering, Chapman University, Orange, CA 92866, USA
| |
Collapse
|
8
|
Sarlabous L, Aquino-Esperanza J, Magrans R, de Haro C, López-Aguilar J, Subirà C, Batlle M, Rué M, Gomà G, Ochagavia A, Fernández R, Blanch L. Development and validation of a sample entropy-based method to identify complex patient-ventilator interactions during mechanical ventilation. Sci Rep 2020; 10:13911. [PMID: 32807815 PMCID: PMC7431581 DOI: 10.1038/s41598-020-70814-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 08/05/2020] [Indexed: 11/28/2022] Open
Abstract
Patient-ventilator asynchronies can be detected by close monitoring of ventilator screens by clinicians or through automated algorithms. However, detecting complex patient-ventilator interactions (CP-VI), consisting of changes in the respiratory rate and/or clusters of asynchronies, is a challenge. Sample Entropy (SE) of airway flow (SE-Flow) and airway pressure (SE-Paw) waveforms obtained from 27 critically ill patients was used to develop and validate an automated algorithm for detecting CP-VI. The algorithm's performance was compared versus the gold standard (the ventilator's waveform recordings for CP-VI were scored visually by three experts; Fleiss' kappa = 0.90 (0.87-0.93)). A repeated holdout cross-validation procedure using the Matthews correlation coefficient (MCC) as a measure of effectiveness was used for optimization of different combinations of SE settings (embedding dimension, m, and tolerance value, r), derived SE features (mean and maximum values), and the thresholds of change (Th) from patient's own baseline SE value. The most accurate results were obtained using the maximum values of SE-Flow (m = 2, r = 0.2, Th = 25%) and SE-Paw (m = 4, r = 0.2, Th = 30%) which report MCCs of 0.85 (0.78-0.86) and 0.78 (0.78-0.85), and accuracies of 0.93 (0.89-0.93) and 0.89 (0.89-0.93), respectively. This approach promises an improvement in the accurate detection of CP-VI, and future study of their clinical implications.
Collapse
Affiliation(s)
- Leonardo Sarlabous
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Spain.
| | - José Aquino-Esperanza
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
- Facultat de Medicina, Universitat de Barcelona, Barcelona, Spain
| | | | - Candelaria de Haro
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
| | - Josefina López-Aguilar
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
| | - Carles Subirà
- Department of Intensive Care, Fundació Althaia, Universitat Internacional de Catalunya , Manresa, Spain
| | - Montserrat Batlle
- Department of Intensive Care, Fundació Althaia, Universitat Internacional de Catalunya , Manresa, Spain
| | - Montserrat Rué
- Department of Basic Medical Sciences, Universitat de Lleida-IRBLLEIDA, Lleida, Spain
| | - Gemma Gomà
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
| | - Ana Ochagavia
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
| | - Rafael Fernández
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
- Department of Intensive Care, Fundació Althaia, Universitat Internacional de Catalunya , Manresa, Spain
| | - Lluís Blanch
- Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain
- Biomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
- BetterCare S.L, Sabadell, Spain
| |
Collapse
|
9
|
Estrada-Petrocelli L, Torres A, Sarlabous L, Rafols-de-Urquia M, Ye-Lin Y, Prats-Boluda G, Jane R, Garcia-Casado J. Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes. IEEE Trans Biomed Eng 2020; 68:1005-1014. [PMID: 32746073 DOI: 10.1109/tbme.2020.3012385] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (Rins/noise), (4) basal sEMG with ECG (Rins/cardio) and (5) expiratory sEMG without ECG (Rins/exp). Spectral power, Rins/noise and Rins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of Rins/cardio and significantly higher median frequencies were obtained for CREs. Rins/noise and Rins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement.
Collapse
|
10
|
Blanco-Almazan D, Groenendaal W, Lozano-Garcia M, Estrada-Petrocelli L, Lijnen L, Smeets C, Ruttens D, Catthoor F, Jane R. Combining Bioimpedance and Myographic Signals for the Assessment of COPD During Loaded Breathing. IEEE Trans Biomed Eng 2020; 68:298-307. [PMID: 32746014 DOI: 10.1109/tbme.2020.2998009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Chronic Obstructive Pulmonary Disease (COPD) is one of the most common chronic conditions. The current assessment of COPD requires a maximal maneuver during a spirometry test to quantify airflow limitations of patients. Other less invasive measurements such as thoracic bioimpedance and myographic signals have been studied as an alternative to classical methods as they provide information about respiration. Particularly, strong correlations have been shown between thoracic bioimpedance and respiratory volume. The main objective of this study is to investigate bioimpedance and its combination with myographic parameters in COPD patients to assess the applicability in respiratory disease monitoring. We measured bioimpedance, surface electromyography and surface mechanomyography in forty-three COPD patients during an incremental inspiratory threshold loading protocol. We introduced two novel features that can be used to assess COPD condition derived from the variation of bioimpedance and the electrical and mechanical activity during each respiratory cycle. These features demonstrate significant differences between mild and severe patients, indicating a lower inspiratory contribution of the inspiratory muscles to global respiratory ventilation in the severest COPD patients. In conclusion, the combination of bioimpedance and myographic signals provides useful indices to noninvasively assess the breathing of COPD patients.
Collapse
|
11
|
Lozano-Garcia M, Nuhic J, Moxham J, Rafferty GF, Jolley CJ, Jane R. Performance Evaluation of Fixed Sample Entropy for Lung Sound Intensity Estimation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2740-2743. [PMID: 33018573 DOI: 10.1109/embc44109.2020.9176215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Lung sound (LS) signals are often contaminated by impulsive artifacts that complicate the estimation of lung sound intensity (LSI) using conventional amplitude estimators. Fixed sample entropy (fSampEn) has proven to be robust to cardiac artifacts in myographic respiratory signals. Similarly, fSampEn is expected to be robust to artifacts in LS signals, thus providing accurate LSI estimates. However, the choice of fSampEn parameters depends on the application and fSampEn has not previously been applied to LS signals. This study aimed to perform an evaluation of the performance of the most relevant fSampEn parameters on LS signals, and to propose optimal fSampEn parameters for LSI estimation. Different combinations of fSampEn parameters were analyzed in LS signals recorded in a heterogeneous population of healthy subjects and chronic obstructive pulmonary disease patients during loaded breathing. The performance of fSampEn was assessed by means of its cross-covariance with flow signals, and optimal fSampEn parameters for LSI estimation were proposed.
Collapse
|
12
|
Estrada-Petrocelli L, Jane R, Torres A. Neural Respiratory Drive Estimation in Respiratory sEMG with Cardiac Arrhythmias. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2748-2751. [PMID: 33018575 DOI: 10.1109/embc44109.2020.9176377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Neural respiratory drive as measured by the electromyography allows the study of the imbalance between the load on respiratory muscles and its capacity. Surface respiratory electromyography (sEMG) is a non-invasive tool used for indirectly assessment of NRD. It also provides a way to evaluate the level and pattern of respiratory muscle activation. The prevalence of electrocardiographic activity (ECG) in respiratory sEMG signals hinders its proper evaluation. Moreover, the occurrence of abnormal heartbeats or cardiac arrhythmias in respiratory sEMG measures can make even more challenging the NRD estimation. Respiratory sEMG can be evaluated using the fixed sample entropy (fSampEn), a technique which is less affected by cardiac artefacts. The aim of this work was to investigate the performance of the fSampEn, the root mean square (RMS) and the average rectified value (ARV) on respiratory sEMG signals with supraventricular arrhythmias (SVA) for NRD estimation. fSampEn, ARV and RMS parameters increased as the inspiratory load increased during the test. fSampEn was less influenced by ECG with SVAs for the NRD estimation showing a greater response to respiratory sEMG, reflected with a higher percentage increase with increasing load (228 % total increase, compared to 142 % and 135 % for ARV and RMS, respectively).
Collapse
|
13
|
van Leuteren RW, Hutten GJ, de Waal CG, Dixon P, van Kaam AH, de Jongh FH. Processing transcutaneous electromyography measurements of respiratory muscles, a review of analysis techniques. J Electromyogr Kinesiol 2019; 48:176-186. [PMID: 31401341 DOI: 10.1016/j.jelekin.2019.07.014] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 07/23/2019] [Accepted: 07/27/2019] [Indexed: 11/28/2022] Open
Abstract
Transcutaneous electromyography (tc-EMG) has been used to measure the electrical activity of respiratory muscles during inspiration in various studies. Processing the raw tc-EMG signal of these inspiratory muscles has shown to be difficult as baseline noise, cardiac interference, cross-talk and motion artefacts can influence the signal quality. In this review we will discuss the most important sources of signal noise in tc-EMG of respiratory muscles and the various techniques described to suppress or reduce this signal noise. Furthermore, we will elaborate on the options available to develop or improve an algorithm that can be used to guide the approach for analysis of tc-EMG signals of inspiratory muscles in future research.
Collapse
Affiliation(s)
- R W van Leuteren
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
| | - G J Hutten
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Vrije Universiteit, Amsterdam, the Netherlands
| | - C G de Waal
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands
| | - P Dixon
- Vyaire Medical, Basingstoke, United Kingdom
| | - A H van Kaam
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Vrije Universiteit, Amsterdam, the Netherlands
| | - F H de Jongh
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Faculty of Science and Technology, University of Twente, Enschede, the Netherlands
| |
Collapse
|
14
|
Estrada L, Sarlabous L, Lozano-Garcia M, Jane R, Torres A. Neural Offset Time Evaluation in Surface Respiratory Signals during Controlled Respiration. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:2344-2347. [PMID: 31946370 DOI: 10.1109/embc.2019.8856767] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The electrical activity of the diaphragm measured by surface electromyography (sEMGdi) provides indirect information on neural respiratory drive. Moreover, it allows evaluating the ventilatory pattern from the onset and offset (ntoff) estimation of the neural inspiratory time. sEMGdi amplitude variation was quantified using the fixed sample entropy (fSampEn), a less sensitive method to the interference from cardiac activity. The detection of the ntoff is controversial, since it is located in an intermediate point between the maximum value and the cessation of sEMGdi inspiratory activity, evaluated by the fSampEn. In this work ntoff detection has been analyzed using thresholds between 40% and 100 % of the fSampEn peak. Furthermore, fSampEn was evaluated analyzing the r parameter from 0.05 to 0.6, using a m equal to 1 and a sliding window size equal to 250 ms. The ntoff has been compared to the offset time (toff) obtained from the airflow during a controlled respiratory protocol varying the fractional inspiratory time from 0.54 to 0.18 whilst the respiratory rate was constant at 16 bpm. Results show that the optimal threshold values were between 66.0 % to 77.0 % of the fSampEn peak value. r values between 0.25 to 0.50 were found suitable to be used with the fSampEn.
Collapse
|
15
|
Changed Temporal Structure of Neuromuscular Control, Rather Than Changed Intersegment Coordination, Explains Altered Stabilographic Regularity after a Moderate Perturbation of the Postural Control System. ENTROPY 2019; 21:e21060614. [PMID: 33267328 PMCID: PMC7515107 DOI: 10.3390/e21060614] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 06/19/2019] [Accepted: 06/19/2019] [Indexed: 11/20/2022]
Abstract
Sample entropy (SaEn) applied on center-of-pressure (COP) data provides a measure for the regularity of human postural control. Two mechanisms could contribute to altered COP regularity: first, an altered temporal structure (temporal regularity) of postural movements (H1); or second, altered coordination between segment movements (coordinative complexity; H2). The current study used rapid, voluntary head-shaking to perturb the postural control system, thus producing changes in COP regularity, to then assess the two hypotheses. Sixteen healthy participants (age 26.5 ± 3.5; seven females), whose postural movements were tracked via 39 reflective markers, performed trials in which they first stood quietly on a force plate for 30 s, then shook their head for 10 s, finally stood quietly for another 90 s. A principal component analysis (PCA) performed on the kinematic data extracted the main postural movement components. Temporal regularity was determined by calculating SaEn on the time series of these movement components. Coordinative complexity was determined by assessing the relative explained variance of the first five components. H1 was supported, but H2 was not. These results suggest that moderate perturbations of the postural control system produce altered temporal structures of the main postural movement components, but do not necessarily change the coordinative structure of intersegment movements.
Collapse
|
16
|
Sarlabous L, Estrada L, Cerezo-Hernández A, V. D. Leest S, Torres A, Jané R, Duiverman M, Garde A. Electromyography-Based Respiratory Onset Detection in COPD Patients on Non-Invasive Mechanical Ventilation. ENTROPY 2019; 21:e21030258. [PMID: 33266973 PMCID: PMC7514739 DOI: 10.3390/e21030258] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/22/2019] [Accepted: 02/28/2019] [Indexed: 11/16/2022]
Abstract
To optimize long-term nocturnal non-invasive ventilation in patients with chronic obstructive pulmonary disease, surface diaphragm electromyography (EMGdi) might be helpful to detect patient-ventilator asynchrony. However, visual analysis is labor-intensive and EMGdi is heavily corrupted by electrocardiographic (ECG) activity. Therefore, we developed an automatic method to detect inspiratory onset from EMGdi envelope using fixed sample entropy (fSE) and a dynamic threshold based on kernel density estimation (KDE). Moreover, we combined fSE with adaptive filtering techniques to reduce ECG interference and improve onset detection. The performance of EMGdi envelopes extracted by applying fSE and fSE with adaptive filtering was compared to the root mean square (RMS)-based envelope provided by the EMG acquisition device. Automatic onset detection accuracy, using these three envelopes, was evaluated through the root mean square error (RMSE) between the automatic and mean visual onsets (made by two observers). The fSE-based method provided lower RMSE, which was reduced from 298 ms to 264 ms when combined with adaptive filtering, compared to 301 ms provided by the RMS-based method. The RMSE was negatively correlated with the proposed EMGdi quality indices. Following further validation, fSE with KDE, combined with adaptive filtering when dealing with low quality EMGdi, indicates promise for detecting the neural onset of respiratory drive.
Collapse
Affiliation(s)
- Leonardo Sarlabous
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Luis Estrada
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Ana Cerezo-Hernández
- Department of Pulmonology, Rio Hortega University Hospital, 47012 Valladolid, Spain
- Department of Pulmonary Diseases/Home mechanical Ventilation, University of Groningen, University Medical Center Groningen, 9713 Groningen, The Netherlands
| | - Sietske V. D. Leest
- Biomedical Signals and Systems Group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, 7500 Enschede, The Netherlands
| | - Abel Torres
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Marieke Duiverman
- Department of Pulmonary Diseases/Home mechanical Ventilation, University of Groningen, University Medical Center Groningen, 9713 Groningen, The Netherlands
- Groningen Research Institute of Asthma and COPD (GRIAC), University of Groningen, 9712 Groningen, The Netherlands
| | - Ainara Garde
- Biomedical Signals and Systems Group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, 7500 Enschede, The Netherlands
- Correspondence: ; Tel.: +31-642-526-154
| |
Collapse
|
17
|
Lozano-García M, Estrada L, Jané R. Performance Evaluation of Fixed Sample Entropy in Myographic Signals for Inspiratory Muscle Activity Estimation. ENTROPY 2019; 21:e21020183. [PMID: 33266898 PMCID: PMC7514665 DOI: 10.3390/e21020183] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 02/06/2019] [Accepted: 02/11/2019] [Indexed: 11/16/2022]
Abstract
Fixed sample entropy (fSampEn) has been successfully applied to myographic signals for inspiratory muscle activity estimation, attenuating interference from cardiac activity. However, several values have been suggested for fSampEn parameters depending on the application, and there is no consensus standard for optimum values. This study aimed to perform a thorough evaluation of the performance of the most relevant fSampEn parameters in myographic respiratory signals, and to propose, for the first time, a set of optimal general fSampEn parameters for a proper estimation of inspiratory muscle activity. Different combinations of fSampEn parameters were used to calculate fSampEn in both non-invasive and the gold standard invasive myographic respiratory signals. All signals were recorded in a heterogeneous population of healthy subjects and chronic obstructive pulmonary disease patients during loaded breathing, thus allowing the performance of fSampEn to be evaluated for a variety of inspiratory muscle activation levels. The performance of fSampEn was assessed by means of the cross-covariance of fSampEn time-series and both mouth and transdiaphragmatic pressures generated by inspiratory muscles. A set of optimal general fSampEn parameters was proposed, allowing fSampEn of different subjects to be compared and contributing to improving the assessment of inspiratory muscle activity in health and disease.
Collapse
Affiliation(s)
- Manuel Lozano-García
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d’Eduard Maristany 10–14, 08930 Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, 08028 Barcelona, Spain
| | - Luis Estrada
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d’Eduard Maristany 10–14, 08930 Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d’Eduard Maristany 10–14, 08930 Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, 08028 Barcelona, Spain
- Correspondence: ; Tel.: +34-93-401-25-38
| |
Collapse
|
18
|
The Effect of Cognitive Resource Competition Due to Dual-Tasking on the Irregularity and Control of Postural Movement Components. ENTROPY 2019; 21:e21010070. [PMID: 33266786 PMCID: PMC7514179 DOI: 10.3390/e21010070] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 01/04/2019] [Accepted: 01/08/2019] [Indexed: 01/04/2023]
Abstract
Postural control research suggests a non-linear, n-shaped relationship between dual-tasking and postural stability. Nevertheless, the extent of this relationship remains unclear. Since kinematic principal component analysis has offered novel approaches to study the control of movement components (PM) and n-shapes have been found in measures of sway irregularity, we hypothesized (H1) that the irregularity of PMs and their respective control, and the control tightness will display the n-shape. Furthermore, according to the minimal intervention principle (H2) different PMs should be affected differently. Finally, (H3) we expected stronger dual-tasking effects in the older population, due to limited cognitive resources. We measured the kinematics of forty-one healthy volunteers (23 aged 26 ± 3; 18 aged 59 ± 4) performing 80 s tandem stances in five conditions (single-task and auditory n-back task; n = 1–4), and computed sample entropies on PM time-series and two novel measures of control tightness. In the PM most critical for stability, the control tightness decreased steadily, and in contrast to H3, decreased further for the younger group. Nevertheless, we found n-shapes in most variables with differing magnitudes, supporting H1 and H2. These results suggest that the control tightness might deteriorate steadily with increased cognitive load in critical movements despite the otherwise eminent n-shaped relationship.
Collapse
|
19
|
Rafols-de-Urquia M, Estrada L, Estevez-Piorno J, Sarlabous L, Jane R, Torres A. Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography. IEEE J Biomed Health Inform 2018; 23:1964-1971. [PMID: 30530375 DOI: 10.1109/jbhi.2018.2885138] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdiW). Simultaneously, a second EMGdi (EMGdiL), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdiW and EMGdiL signals: heart rate, respiratory rate, respiratory muscle activity, and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdiW and the reference signal data: heart rate (R = 0.947), respiratory rate (R = 0.940), respiratory muscle activity (R = 0.877), and mean frequency (R = 0.895). Moreover, similar increments in EMGdiW and EMGdiL activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases.
Collapse
|
20
|
Lozano-Garcia M, Sarlabous L, Moxham J, Rafferty GF, Torres A, Jolley CJ, Jane R. Assessment of Inspiratory Muscle Activation using Surface Diaphragm Mechanomyography and Crural Diaphragm Electromyography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:3342-3345. [PMID: 30441104 DOI: 10.1109/embc.2018.8513046] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The relationship between surface diaphragm mechanomyography (sMMGdi), as a noninvasive measure of inspiratory muscle mechanical activation, and crural diaphragm electromyography (oesEMGdi), as the invasive gold standard measure of diaphragm electrical activation, had not previously been examined. To investigate this relationship, oesEMGdi and sMMGdi were measured simultaneously in 6 healthy subjects during an incremental inspiratory threshold loading protocol, and analyzed using fixed sample entropy (fSampEn). A positive curvilinear relationship was observed between mean fSampEn sMMGdi and oesEMGdi (r = 0.67). Accordingly, an increasing electromechanical ratio was also observed with increasing inspiratory load. These findings suggest that sMMGdi could provide useful noninvasive measures of inspiratory muscle mechanical activation.
Collapse
|
21
|
Lozano-García M, Sarlabous L, Moxham J, Rafferty GF, Torres A, Jané R, Jolley CJ. Surface mechanomyography and electromyography provide non-invasive indices of inspiratory muscle force and activation in healthy subjects. Sci Rep 2018; 8:16921. [PMID: 30446712 PMCID: PMC6240075 DOI: 10.1038/s41598-018-35024-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 10/28/2018] [Indexed: 11/30/2022] Open
Abstract
The current gold standard assessment of human inspiratory muscle function involves using invasive measures of transdiaphragmatic pressure (Pdi) or crural diaphragm electromyography (oesEMGdi). Mechanomyography is a non-invasive measure of muscle vibration associated with muscle contraction. Surface electromyogram and mechanomyogram, recorded transcutaneously using sensors placed over the lower intercostal spaces (sEMGlic and sMMGlic respectively), have been proposed to provide non-invasive indices of inspiratory muscle activation, but have not been directly compared to gold standard Pdi and oesEMGdi measures during voluntary respiratory manoeuvres. To validate the non-invasive techniques, the relationships between Pdi and sMMGlic, and between oesEMGdi and sEMGlic were measured simultaneously in 12 healthy subjects during an incremental inspiratory threshold loading protocol. Myographic signals were analysed using fixed sample entropy (fSampEn), which is less influenced by cardiac artefacts than conventional root mean square. Strong correlations were observed between: mean Pdi and mean fSampEn |sMMGlic| (left, 0.76; right, 0.81), the time-integrals of the Pdi and fSampEn |sMMGlic| (left, 0.78; right, 0.83), and mean fSampEn oesEMGdi and mean fSampEn sEMGlic (left, 0.84; right, 0.83). These findings suggest that sMMGlic and sEMGlic could provide useful non-invasive alternatives to Pdi and oesEMGdi for the assessment of inspiratory muscle function in health and disease.
Collapse
Affiliation(s)
- Manuel Lozano-García
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain.
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain.
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain.
| | - Leonardo Sarlabous
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - John Moxham
- Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| | - Gerrard F Rafferty
- King's College Hospital NHS Foundation Trust, King's Health Partners, London, United Kingdom
- Centre for Human & Applied Physiological Sciences, School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| | - Abel Torres
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation group, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Barcelona, Spain
| | - Caroline J Jolley
- King's College Hospital NHS Foundation Trust, King's Health Partners, London, United Kingdom
- Centre for Human & Applied Physiological Sciences, School of Basic & Medical Biosciences, Faculty of Life Sciences & Medicine, King's College London, King's Health Partners, London, United Kingdom
| |
Collapse
|
22
|
Human Postural Control: Assessment of Two Alternative Interpretations of Center of Pressure Sample Entropy through a Principal Component Factorization of Whole-Body Kinematics. ENTROPY 2018; 20:e20010030. [PMID: 33265120 PMCID: PMC7512231 DOI: 10.3390/e20010030] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 12/21/2017] [Accepted: 01/01/2018] [Indexed: 11/19/2022]
Abstract
Sample entropy (SaEn), calculated for center of pressure (COP) trajectories, is often distinct for compromised postural control, e.g., in Parkinson, stroke, or concussion patients, but the interpretation of COP-SaEn remains subject to debate. The purpose of this paper is to test the hypotheses that COP-SaEn is related (Hypothesis 1; H1) to the complexity of the postural movement structures, i.e., to the utilization and coordination of the mechanical degrees of freedom; or (Hypothesis 2; H2) to the irregularity of the individual postural movement strategies, i.e., to the neuromuscular control of these movements. Twenty-one healthy volunteers (age 26.4 ± 2.4; 10 females), equipped with 27 reflective markers, stood on a force plate and performed 2-min quiet stances. Principal movement strategies (PMs) were obtained from a principal component analysis (PCA) of the kinematic data. Then SaEn was calculated for the COP and PM time-series. H1 was tested by correlating COP-SaEn to the relative contribution of the PMs to the subject specific overall movement and H2 by correlating COP-SaEn and PM-SaEn. Both hypotheses were supported. This suggests that in a healthy population the COP-SaEn is linked to the complexity of the coordinative structure of postural movements, as well as to the irregularity of the neuromuscular control of specific movement components.
Collapse
|