1
|
Huang PH, Hsiao TC. Use of Intrinsic Entropy to Assess the Instantaneous Complexity of Thoracoabdominal Movement Patterns to Indicate the Effect of the Iso-Volume Maneuver Trial on the Performance of the Step Test. ENTROPY (BASEL, SWITZERLAND) 2023; 26:27. [PMID: 38248153 PMCID: PMC10814788 DOI: 10.3390/e26010027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/21/2023] [Accepted: 12/23/2023] [Indexed: 01/23/2024]
Abstract
The recent surge in interest surrounds the analysis of physiological signals with a non-linear dynamic approach. The measurement of entropy serves as a renowned method for indicating the complexity of a signal. However, there is a dearth of research concerning the non-linear dynamic analysis of respiratory signals. Therefore, this study employs a novel method known as intrinsic entropy (IE) to assess the short-term dynamic changes in thoracoabdominal movement patterns, as measured by respiratory inductance plethysmography (RIP), during various states such as resting, step test, recovery, and iso-volume maneuver (IVM) trials. The findings reveal a decrease in IE of thoracic wall movement (TWM) and an increase in IE of abdominal wall movement (AWM) following the IVM trial. This suggests that AWM may dominate the breathing exercise after the IVM trial. Moreover, due to the high temporal resolution of IE, it proves to be a suitable measure for assessing the complexity of thoracoabdominal movement patterns under non-stationary states such as the step test and recovery. The results also demonstrate that the instantaneous complexity of TWM and AWM can effectively capture instantaneous changes during non-stationary states, which may prove valuable in understanding the respiratory mechanism for healthcare purposes in daily life.
Collapse
Affiliation(s)
- Po-Hsun Huang
- Institute of Computer Science and Engineering, College of Computer Science, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan;
| | - Tzu-Chien Hsiao
- Institute of Computer Science and Engineering, College of Computer Science, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan;
- Department of Computer Science, College of Computer Science, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| |
Collapse
|
2
|
Pichardo-Carmona EY, Reyes-Lagos JJ, Ceballos-Juárez RG, Ledesma-Ramírez CI, Mendieta-Zerón H, Peña-Castillo MÁ, Nsugbe E, Porta-García MÁ, Mina-Paz Y. Changes in the autonomic cardiorespiratory activity in parturient women with severe and moderate features of preeclampsia. Front Immunol 2023; 14:1190699. [PMID: 37724103 PMCID: PMC10505439 DOI: 10.3389/fimmu.2023.1190699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 08/03/2023] [Indexed: 09/20/2023] Open
Abstract
Background Cardiorespiratory coupling (CRC) is a physiological phenomenon that reflects the mutual interaction between the cardiac and respiratory control systems. It is mainly associated with efferent vagal activity from the central autonomic network. Few studies have explored the autonomic changes of CRC in preeclampsia, a critical obstetric complication related to possible autonomic dysfunctions and inflammatory disturbances. This study examined the autonomic mechanisms of CRC in women with severe and moderate preeclampsia and healthy controls by applying nonlinear methods based on information theory, such as mutual information (MI) and Renyi's mutual information (RMI) and the linear and nonlinear analysis of the Pulse-Respiration Quotient (PRQ). Methods We studied three groups of parturient women in the third trimester of pregnancy with a clinical diagnosis of preeclampsia without severe symptoms (P, 38.5 ± 1.4 weeks of pregnancy, n=19), preeclampsia with severe symptoms (SP, 37.5 ± 0.9 weeks of pregnancy, n=22), and normotensive control women (C, 39.1 ± 1.3 weeks of pregnancy, n=20). 10-minutes of abdominal electrocardiograms (ECG) and respiratory signals (RESP) were recorded in all the participants. Subsequently, we obtained the maternal beat-to-beat (RR) and breath-to-breath (BB) time series from ECG and RESP, respectively. The CRC between RR and BB was quantified by nonlinear methods based on information theory, such as MI and RMI, along with the analysis of the novel index of PRQ. Subsequently, we computed the mean PRQ (mPRQ) and the normalized permutation entropy (nPermEn_PRQ) from the PRQ time series generated from BB and RR. In addition, we examined the vagal activity in the three groups by the logarithm of the median of the distribution of the absolute values of successive RR differences (logRSA). Results The MI and RMI values were significantly lower (p<0.05) in the preeclamptic groups compared to the control group. However, no significant differences were found between the preeclamptic groups. The logRSA and nPermEn_PRQ indices were significantly lower (p<0.05) in SP compared to C and P. Conclusion Our data suggest that parturient women with severe and mild preeclampsia may manifest an altered cardiorespiratory coupling compared with normotensive control women. Disrupted CRC in severe preeclampsia could be associated with vagal withdrawal and less complex cardiorespiratory dynamics. The difference in vagal activity between the preeclamptic groups may suggest a further reduction in vagal activity associated with the severity of the disease.
Collapse
Affiliation(s)
| | | | | | | | - Hugo Mendieta-Zerón
- School of Medicine, Autonomous University of the State of Mexico (UAEMéx), Toluca, Mexico
- Mónica Pretelini Sáenz Maternal-Perinatal Hospital, Health Institute of the State of Mexico (ISEM), Toluca, Mexico
| | | | - Ejay Nsugbe
- Nsugbe Research Labs, Swindon, United Kingdom
| | | | - Yecid Mina-Paz
- Faculty of Health Sciences, Universidad Libre Seccional Cali, Cali, Colombia
| |
Collapse
|
3
|
Modified multiscale transfer entropy analysis of intra- and inter-couplings of cardio-respiratory systems during meditation. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.103983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
4
|
A novel approach GRNTSTE to reconstruct gene regulatory interactions applied to a case study for rat pineal rhythm gene. Sci Rep 2022; 12:10227. [PMID: 35715583 PMCID: PMC9205975 DOI: 10.1038/s41598-022-14903-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 06/14/2022] [Indexed: 01/13/2023] Open
Abstract
Accurate inference and prediction of gene regulatory network are very important for understanding dynamic cellular processes. The large-scale time series genomics data are helpful to reveal the molecular dynamics and dynamic biological processes of complex biological systems. Firstly, we collected the time series data of the rat pineal gland tissue in the natural state according to a fixed sampling rate, and performed whole-genome sequencing. The large-scale time-series sequencing data set of rat pineal gland was constructed, which includes 480 time points, the time interval between adjacent time points is 3 min, and the sampling period is 24 h. Then, we proposed a new method of constructing gene expression regulatory network, named the gene regulatory network based on time series data and entropy transfer (GRNTSTE) method. The method is based on transfer entropy and large-scale time-series gene expression data to infer the causal regulatory relationship between genes in a data-driven mode. The comparative experiments prove that GRNTSTE has better performance than dynamical gene network inference with ensemble of trees (dynGENIE3) and SCRIBE, and has similar performance to TENET. Meanwhile, we proved that the performance of GRNTSTE is slightly lower than that of SINCERITIES method and better than other gene regulatory network construction methods in BEELINE framework, which is based on the BEELINE data set. Finally, the rat pineal rhythm gene expression regulatory network was constructed by us based on the GRNTSTE method, which provides an important reference for the study of the pineal rhythm mechanism, and is of great significance to the study of the pineal rhythm mechanism.
Collapse
|
5
|
Qin H, Liu G. A dual-model deep learning method for sleep apnea detection based on representation learning and temporal dependence. Neurocomputing 2022. [DOI: 10.1016/j.neucom.2021.12.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Weng P, Wei K, Chen T, Chen M, Liu G. Fuzzy Approximate Entropy of Extrema Based on Multiple Moving Averages as a Novel Approach in Obstructive Sleep Apnea Screening. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2022; 10:4901211. [PMID: 36247084 PMCID: PMC9564195 DOI: 10.1109/jtehm.2022.3197084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/17/2022] [Accepted: 07/25/2022] [Indexed: 11/29/2022]
Abstract
Objective: Obstructive sleep apnea (OSA) is a respiratory disease associated with autonomic nervous system dysfunction. As a novel method for analyzing OSA depending on heart rate variability, fuzzy approximate entropy of extrema based on multiple moving averages (Emma-fApEn) can effectively assess the sympathetic tension limits, thereby realizing a good performance in the disease severity screening. Method: Sixty 6-h electrocardiogram recordings (20 healthy, 16 mild/moderate OSA and 34 severe OSA) from the PhysioNet database were used in this study. The performances of minima of Emma-fApEn (fApEn-minima), maxima of Emma-fApEn (fApEn-maxima) and classic time-frequency domain indices for each recording were assessed by significance analysis, correlation analysis, parameter optimization and OSA screening. Results: fApEn-minima and fApEn-maxima had significant differences between the severe OSA group and the other two groups, while the mean value (Mean) and the ratio of low-frequency power and high-frequency power (LH) could significantly differentiate OSA recordings from healthy recordings. The correlation coefficient between fApEn-minima and apnea-hypopnea index was the highest (|R| = 0.705). Machine learning methods were used to evaluate the performances of the above four indices. Random forest (RF) achieved the highest accuracy of 96.67% in OSA screening and 91.67% in severe OSA screening, with a good balance in both. Conclusion: Emma-fApEn may be used as a simple preliminary detection tool to assess the severity of OSA prior to polysomnography analysis.
Collapse
Affiliation(s)
- Peiyu Weng
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Keming Wei
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Tian Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Mingjing Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Guanzheng Liu
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
Liu Z, Chen T, Wei K, Liu G, Liu B. Similarity Changes Analysis for Heart Rate Fluctuation Regularity as a New Screening Method for Congestive Heart Failure. ENTROPY (BASEL, SWITZERLAND) 2021; 23:1669. [PMID: 34945975 PMCID: PMC8700114 DOI: 10.3390/e23121669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 11/26/2021] [Accepted: 11/30/2021] [Indexed: 11/21/2022]
Abstract
Congestive heart failure (CHF) is a chronic cardiovascular condition associated with dysfunction of the autonomic nervous system (ANS). Heart rate variability (HRV) has been widely used to assess ANS. This paper proposes a new HRV analysis method, which uses information-based similarity (IBS) transformation and fuzzy approximate entropy (fApEn) algorithm to obtain the fApEn_IBS index, which is used to observe the complexity of autonomic fluctuations in CHF within 24 h. We used 98 ECG records (54 health records and 44 CHF records) from the PhysioNet database. The fApEn_IBS index was statistically significant between the control and CHF groups (p < 0.001). Compared with the classical indices low-to-high frequency power ratio (LF/HF) and IBS, the fApEn_IBS index further utilizes the changes in the rhythm of heart rate (HR) fluctuations between RR intervals to fully extract relevant information between adjacent time intervals and significantly improves the performance of CHF screening. The CHF classification accuracy of fApEn_IBS was 84.69%, higher than LF/HF (77.55%) and IBS (83.67%). Moreover, the combination of IBS, fApEn_IBS, and LF/HF reached the highest CHF screening accuracy (98.98%) with the random forest (RF) classifier, indicating that the IBS and LF/HF had good complementarity. Therefore, fApEn_IBS effusively reflects the complexity of autonomic nerves in CHF and is a valuable CHF assessment tool.
Collapse
Affiliation(s)
- Zeming Liu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China; (Z.L.); (T.C.); (K.W.)
- School of Science, Hua Zhong Agricultural University, Wuhan 430070, China
| | - Tian Chen
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China; (Z.L.); (T.C.); (K.W.)
| | - Keming Wei
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China; (Z.L.); (T.C.); (K.W.)
| | - Guanzheng Liu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China; (Z.L.); (T.C.); (K.W.)
| | - Bin Liu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China; (Z.L.); (T.C.); (K.W.)
| |
Collapse
|
8
|
Martín-Montero A, Gutiérrez-Tobal GC, Gozal D, Barroso-García V, Álvarez D, del Campo F, Kheirandish-Gozal L, Hornero R. Bispectral Analysis of Heart Rate Variability to Characterize and Help Diagnose Pediatric Sleep Apnea. ENTROPY (BASEL, SWITZERLAND) 2021; 23:1016. [PMID: 34441156 PMCID: PMC8394544 DOI: 10.3390/e23081016] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 07/28/2021] [Accepted: 08/03/2021] [Indexed: 12/28/2022]
Abstract
Pediatric obstructive sleep apnea (OSA) is a breathing disorder that alters heart rate variability (HRV) dynamics during sleep. HRV in children is commonly assessed through conventional spectral analysis. However, bispectral analysis provides both linearity and stationarity information and has not been applied to the assessment of HRV in pediatric OSA. Here, this work aimed to assess HRV using bispectral analysis in children with OSA for signal characterization and diagnostic purposes in two large pediatric databases (0-13 years). The first database (training set) was composed of 981 overnight ECG recordings obtained during polysomnography. The second database (test set) was a subset of the Childhood Adenotonsillectomy Trial database (757 children). We characterized three bispectral regions based on the classic HRV frequency ranges (very low frequency: 0-0.04 Hz; low frequency: 0.04-0.15 Hz; and high frequency: 0.15-0.40 Hz), as well as three OSA-specific frequency ranges obtained in recent studies (BW1: 0.001-0.005 Hz; BW2: 0.028-0.074 Hz; BWRes: a subject-adaptive respiratory region). In each region, up to 14 bispectral features were computed. The fast correlation-based filter was applied to the features obtained from the classic and OSA-specific regions, showing complementary information regarding OSA alterations in HRV. This information was then used to train multi-layer perceptron (MLP) neural networks aimed at automatically detecting pediatric OSA using three clinically defined severity classifiers. Both classic and OSA-specific MLP models showed high and similar accuracy (Acc) and areas under the receiver operating characteristic curve (AUCs) for moderate (classic regions: Acc = 81.0%, AUC = 0.774; OSA-specific regions: Acc = 81.0%, AUC = 0.791) and severe (classic regions: Acc = 91.7%, AUC = 0.847; OSA-specific regions: Acc = 89.3%, AUC = 0.841) OSA levels. Thus, the current findings highlight the usefulness of bispectral analysis on HRV to characterize and diagnose pediatric OSA.
Collapse
Affiliation(s)
- Adrián Martín-Montero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - David Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, 47012 Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| |
Collapse
|
9
|
Ozimek M, Żebrowski JJ, Baranowski R. Information Flow Between Heart Rhythm, Repolarization, and the Diastolic Interval Series for Healthy Individuals and LQTS1 Patients. Front Physiol 2021; 12:611731. [PMID: 34163369 PMCID: PMC8215390 DOI: 10.3389/fphys.2021.611731] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 04/08/2021] [Indexed: 11/13/2022] Open
Abstract
Using information theoretic measures, relations between heart rhythm, repolarization in the tissue of the heart, and the diastolic interval time series are analyzed. These processes are a fragment of the cardiovascular physiological network. A comparison is made between the results for 84 (42 women) healthy individuals and 65 (45 women) long QT syndrome type 1 (LQTS1) patients. Self-entropy, transfer entropy, and joint transfer entropy are calculated for the three time series and their combinations. The results for self-entropy indicate the well-known result that regularity of heart rhythm for healthy individuals is larger than that of QT interval series. The flow of information depends on the direction with the flow from the heart rhythm to QT dominating. In LQTS1 patients, however, our results indicate that information flow in the opposite direction may occur—a new result. The information flow from the heart rhythm to QT dominates, which verifies the asymmetry seen by Porta et al. in the variable tilt angle experiment. The amount of new information and self-entropy for LQTS1 patients is smaller than that for healthy individuals. However, information transfers from RR to QT and from DI to QT are larger in the case of LQTS1 patients.
Collapse
Affiliation(s)
- Mateusz Ozimek
- Cardiovascular Physics Group, Physics of Complex Systems Division, Faculty of Physics, Warsaw University of Technology, Warszawa, Poland
| | - Jan J Żebrowski
- Cardiovascular Physics Group, Physics of Complex Systems Division, Faculty of Physics, Warsaw University of Technology, Warszawa, Poland
| | - Rafał Baranowski
- Cardiovascular Physics Group, Physics of Complex Systems Division, Faculty of Physics, Warsaw University of Technology, Warszawa, Poland.,Institute of Cardiology, Warszawa-Anin, Poland
| |
Collapse
|
10
|
Wu S, Liang D, Yang Q, Liu G. Regularity of heart rate fluctuations analysis in obstructive sleep apnea patients using information-based similarity. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2020.102370] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
11
|
Application of the Variance Delay Fuzzy Approximate Entropy for Autonomic Nervous System Fluctuation Analysis in Obstructive Sleep Apnea Patients. ENTROPY 2020; 22:e22090915. [PMID: 33286684 PMCID: PMC7597154 DOI: 10.3390/e22090915] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 07/21/2020] [Accepted: 07/27/2020] [Indexed: 12/12/2022]
Abstract
Obstructive sleep apnea (OSA) is a fatal respiratory disease occurring in sleep. OSA can induce declined heart rate variability (HRV) and was reported to have autonomic nerve system (ANS) dysfunction. Variance delay fuzzy approximate entropy (VD_fApEn) was proposed as a nonlinear index to study the fluctuation change of ANS in OSA patients. Sixty electrocardiogram (ECG) recordings of the PhysioNet database (20 normal, 14 mild-moderate OSA, and 26 severe OSA) were intercepted for 6 h and divided into 5-min segments. HRV analysis were adopted in traditional frequency domain, and nonlinear HRV indices were also calculated. Among these indices, VD_fApEn could significantly differentiate among the three groups (p < 0.05) compared with the ratio of low frequency power and high frequency power (LF/HF ratio) and fuzzy approximate entropy (fApEn). Moreover, the VD_fApEn (90%) reached a higher OSA screening accuracy compared with LF/HF ratio (80%) and fApEn (78.3%). Therefore, VD_fApEn provides a potential clinical method for ANS fluctuation analysis in OSA patients and OSA severity analysis.
Collapse
|
12
|
Pérez-Gutiérrez MF, Sánchez-Muñoz JJ, Erazo-Rodas M, Guerrero-Curieses A, Everss E, Quesada-Dorador A, Ruiz-Granell R, Ibáñez-Criado A, Bellver-Navarro A, Rojo-Álvarez JL, García-Alberola A. Spectral Analysis and Mutual Information Estimation of Left and Right Intracardiac Electrograms during Ventricular Fibrillation. SENSORS (BASEL, SWITZERLAND) 2020; 20:s20154162. [PMID: 32726931 PMCID: PMC7435921 DOI: 10.3390/s20154162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 07/19/2020] [Accepted: 07/22/2020] [Indexed: 06/11/2023]
Abstract
Ventricular fibrillation (VF) signals are characterized by highly volatile and erratic electrical impulses, the analysis of which is difficult given the complex behavior of the heart rhythms in the left (LV) and right ventricles (RV), as sometimes shown in intracardiac recorded Electrograms (EGM). However, there are few studies that analyze VF in humans according to the simultaneous behavior of heart signals in the two ventricles. The objective of this work was to perform a spectral and a non-linear analysis of the recordings of 22 patients with Congestive Heart Failure (CHF) and clinical indication for a cardiac resynchronization device, simultaneously obtained in LV and RV during induced VF in patients with a Biventricular Implantable Cardioverter Defibrillator (BICD) Contak Renewal IVTM (Boston Sci.). The Fourier Transform was used to identify the spectral content of the first six seconds of signals recorded in the RV and LV simultaneously. In addition, measurements that were based on Information Theory were scrutinized, including Entropy and Mutual Information. The results showed that in most patients the spectral envelopes of the EGM sources of RV and LV were complex, different, and with several frequency peaks. In addition, the Dominant Frequency (DF) in the LV was higher than in the RV, while the Organization Index (OI) had the opposite trend. The entropy measurements were more regular in the RV than in the LV, thus supporting the spectral findings. We can conclude that basic stochastic processing techniques should be scrutinized with caution and from basic to elaborated techniques, but they can provide us with useful information on the biosignals from both ventricles during VF.
Collapse
Affiliation(s)
- Milton Fabricio Pérez-Gutiérrez
- Departamento de Eléctrica y Electrónica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumiñahui s/n, Sangolquí 171-5-231B, Ecuador;
| | - Juan José Sánchez-Muñoz
- Arrhythmia Unit and Electrophysiology, Department of Cardiology, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria, 30120 Murcia, Spain; (J.J.S.-M.); (A.G.-A.)
| | - Mayra Erazo-Rodas
- Departamento de Eléctrica y Electrónica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumiñahui s/n, Sangolquí 171-5-231B, Ecuador;
| | - Alicia Guerrero-Curieses
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain; (A.G.-C.); (E.E.); (J.L.R.-Á.)
| | - Estrella Everss
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain; (A.G.-C.); (E.E.); (J.L.R.-Á.)
| | - Aurelio Quesada-Dorador
- Arrhythmia Unit, Department of Cardiology, Hospital General de Valencia, 46014 Valencia, Spain;
| | - Ricardo Ruiz-Granell
- Arrhythmia Unit, Department of Cardiology, Hospital Clínico Universitario, Av. Blasco Ibañez, 17, 46010 Valencia, Spain;
| | - Alicia Ibáñez-Criado
- Arrhythmia Unit, Department of Cardiology, Hospital Clínico de Alicante, 03010 Alicante, Spain;
| | | | - José Luis Rojo-Álvarez
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain; (A.G.-C.); (E.E.); (J.L.R.-Á.)
| | - Arcadi García-Alberola
- Arrhythmia Unit and Electrophysiology, Department of Cardiology, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria, 30120 Murcia, Spain; (J.J.S.-M.); (A.G.-A.)
| |
Collapse
|
13
|
Chen M, He A, Feng K, Liu G, Wang Q. Empirical Mode Decomposition as a Novel Approach to Study Heart Rate Variability in Congestive Heart Failure Assessment. ENTROPY 2019; 21:1169. [PMCID: PMC7514513 DOI: 10.3390/e21121169] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 11/22/2019] [Indexed: 06/17/2023]
Abstract
Congestive heart failure (CHF) is a cardiovascular disease related to autonomic nervous system (ANS) dysfunction and fragmented patterns. There is a growing demand for assessing CHF accurately. In this work, 24-h RR interval signals (the time elapsed between two successive R waves of the QRS signal on the electrocardiogram) of 98 subjects (54 healthy and 44 CHF subjects) were analyzed. Empirical mode decomposition (EMD) was chosen to decompose RR interval signals into four intrinsic mode functions (IMFs). Then transfer entropy (TE) was employed to study the information transaction among four IMFs. Compared with the normal group, significant decrease in TE (*→1; information transferring from other IMFs to IMF1, p < 0.001) and TE (3→*; information transferring from IMF3 to other IMFs, p < 0.05) was observed. Moreover, the combination of TE (*→1), TE (3→*) and LF/HF reached the highest CHF screening accuracy (85.7%) in IBM SPSS Statistics discriminant analysis, while LF/HF only achieved 79.6%. This novel method and indices could serve as a new way to assessing CHF and studying the interaction of the physiological phenomena. Simulation examples and transfer entropy applications are provided to demonstrate the effectiveness of the proposed EMD decomposition method in assessing CHF.
Collapse
Affiliation(s)
- Mingjing Chen
- Department of Biomedical Engineering, School of Basic Medical Sciences, Guangzhou Medical University, Guangzhou 511436, China;
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China; (A.H.); (K.F.); (G.L.)
| | - Aodi He
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China; (A.H.); (K.F.); (G.L.)
| | - Kaicheng Feng
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China; (A.H.); (K.F.); (G.L.)
| | - Guanzheng Liu
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China; (A.H.); (K.F.); (G.L.)
| | - Qian Wang
- Department of Biomedical Engineering, School of Basic Medical Sciences, Guangzhou Medical University, Guangzhou 511436, China;
| |
Collapse
|
14
|
Buszko K, Piątkowska A, Koźluk E, Fabiszak T, Opolski G. Transfer Information Assessment in Diagnosis of Vasovagal Syncope Using Transfer Entropy. ENTROPY (BASEL, SWITZERLAND) 2019; 21:e21040347. [PMID: 33267061 PMCID: PMC7514832 DOI: 10.3390/e21040347] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 03/25/2019] [Accepted: 03/26/2019] [Indexed: 06/12/2023]
Abstract
The paper presents an application of Transfer Entropy (TE) to the analysis of information transfer between biosignals (heart rate expressed as R-R intervals (RRI), blood pressure (sBP, dBP) and stroke volume (SV)) measured during head up tilt testing (HUTT) in patients with suspected vasovagal syndrome. The study group comprised of 80 patients who were divided into two groups: the HUTT(+) group consisting of 57 patients who developed syncope during the passive phase of the test and HUTT(-) group consisting of 23 patients who had a negative result of the passive phase and experienced syncope after provocation with nitroglycerin. In both groups the information transfer depends on the phase of the tilt test. In supine position the highest transfer occurred between driver RRI and other components. In upright position it is the driver sBP that plays the crucial role. The pre-syncope phase features the highest information transfer from driver SV to blood pressure components. In each group the comparisons of TE between different phases of HUT test showed significant differences for RRI and SV as drivers.
Collapse
Affiliation(s)
- Katarzyna Buszko
- Department of Theoretical Foundations of Bio-Medical Science and Medical Informatics, Collegium Medicum, Nicolaus Copernicus University, 85-067 Bydgoszcz, Poland
| | - Agnieszka Piątkowska
- Department of Emergency Medicine, Wroclaw Medical University, 50-556 Wroclaw, Poland
- 1st Chair and Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
| | - Edward Koźluk
- 1st Chair and Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
| | - Tomasz Fabiszak
- Department of Cardiology and Internal Diseases, Collegium Medicum, Nicolaus Copernicus University, 85-067 Bydgoszcz, Poland
| | - Grzegorz Opolski
- 1st Chair and Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
| |
Collapse
|
15
|
Li Y, Pan W, Li K, Jiang Q, Liu G. Sliding Trend Fuzzy Approximate Entropy as a Novel Descriptor of Heart Rate Variability in Obstructive Sleep Apnea. IEEE J Biomed Health Inform 2019; 23:175-183. [DOI: 10.1109/jbhi.2018.2790968] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
16
|
Luo D, Pan W, Li Y, Feng K, Liu G. The Interaction Analysis between the Sympathetic and Parasympathetic Systems in CHF by Using Transfer Entropy Method. ENTROPY (BASEL, SWITZERLAND) 2018; 20:e20100795. [PMID: 33265883 PMCID: PMC7512358 DOI: 10.3390/e20100795] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Revised: 10/05/2018] [Accepted: 10/09/2018] [Indexed: 06/12/2023]
Abstract
Congestive heart failure (CHF) is a cardiovascular disease associated with autonomic dysfunction, where sympathovagal imbalance was reported in many studies using heart rate variability (HRV). To learn more about the dynamic interaction in the autonomic nervous system (ANS), we explored the directed interaction between the sympathetic nervous system (SNS) and the parasympathetic nervous system (PNS) with the help of transfer entropy (TE). This article included 24-h RR interval signals of 54 healthy subjects (31 males and 23 females, 61.38 ± 11.63 years old) and 44 CHF subjects (8 males and 2 females, 19 subjects' gender were unknown, 55.51 ± 11.44 years old, 4 in class I, 8 in class II and 32 in class III~IV, according to the New York Heart Association Function Classification), obtained from the PhysioNet database and then segmented into 5-min non-overlapping epochs using cubic spline interpolation. For each segment in the normal group and CHF group, frequency-domain features included low-frequency (LF) power, high-frequency (HF) power and LF/HF ratio were extracted as classical estimators of autonomic activity. In the nonlinear domain, TE between LF and HF were calculated to quantify the information exchanging between SNS and PNS. Compared with the normal group, an extreme decrease in LF/HF ratio (p = 0.000) and extreme increases in both TE(LF→HF) (p = 0.000) and TE(HF→LF) (p = 0.000) in the CHF group were observed. Moreover, both in normal and CHF groups, TE(LF→HF) was a lot greater than TE(HF→LF) (p = 0.000), revealing that TE was able to distinguish the difference in the amount of directed information transfer among ANS. Extracted features were further applied in discriminating CHF using IBM SPSS Statistics discriminant analysis. The combination of the LF/HF ratio, TE(LF→HF) and TE(HF→LF) reached the highest screening accuracy (83.7%). Our results suggested that TE could serve as a complement to traditional index LF/HF in CHF screening.
Collapse
Affiliation(s)
- Daiyi Luo
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510275, China
| | - Weifeng Pan
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510275, China
| | - Yifan Li
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510275, China
| | - Kaicheng Feng
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510275, China
| | - Guanzheng Liu
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510275, China
| |
Collapse
|
17
|
Erazo-Rodas M, Sandoval-Moreno M, Muñoz-Romero S, Huerta M, Rivas-Lalaleo D, Rojo-Álvarez JL. Multiparametric Monitoring in Equatorian Tomato Greenhouses (III): Environmental Measurement Dynamics. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2557. [PMID: 30081567 PMCID: PMC6111834 DOI: 10.3390/s18082557] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 07/31/2018] [Accepted: 08/02/2018] [Indexed: 11/20/2022]
Abstract
World population growth currently brings unequal access to food, whereas crop yields are not increasing at a similar rate, so that future food demand could be unmet. Many recent research works address the use of optimization techniques and technological resources on precision agriculture, especially in large demand crops, including climatic variables monitoring using wireless sensor networks (WSNs). However, few studies have focused on analyzing the dynamics of the environmental measurement properties in greenhouses. In the two companion papers, we describe the design and implementation of three WSNs with different technologies and topologies further scrutinizing their comparative performance, and a detailed analysis of their energy consumption dynamics is also presented, both considering tomato greenhouses in the Andean region of Ecuador. The three WSNs use ZigBee with star topology, ZigBee with mesh topology (referred to here as DigiMesh), and WiFi with access point topology. The present study provides a systematic and detailed analysis of the environmental measurement dynamics from multiparametric monitoring in Ecuadorian tomato greenhouses. A set of monitored variables (including CO2, air temperature, and wind direction, among others) are first analyzed in terms of their intrinsic variability and their short-term (circadian) rhythmometric behavior. Then, their cross-information is scrutinized in terms of scatter representations and mutual information analysis. Based on Bland⁻Altman diagrams, good quality rhythmometric models were obtained at high-rate sampling signals during four days when using moderate regularization and preprocessing filtering with 100-coefficient order. Accordingly, and especially for the adjustment of fast transition variables, it is appropriate to use high sampling rates and then to filter the signal to discriminate against false peaks and noise. In addition, for variables with similar behavior, a longer period of data acquisition is required for the adequate processing, which makes more precise the long-term modeling of the environmental signals.
Collapse
Affiliation(s)
- Mayra Erazo-Rodas
- Departamento de Eléctrica y Electrónica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumiñahui s/n, Sangolquí 171-5-231B, Ecuador.
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain.
| | - Mary Sandoval-Moreno
- Departamento de Ciencias Exactas, Universidad de las Fuerzas Armadas ESPE, Av. General Rumiñahui s/n, Sangolquí 171-5-231B, Ecuador.
| | - Sergio Muñoz-Romero
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain.
- Center for Computational Simulation, Universidad Politécnica de Madrid, Boadilla del Monte, 28660 Madrid, Spain.
| | - Mónica Huerta
- Carrera de Telecomunicaciones, Universidad Politécnica Salesiana, Cuenca 010105, Ecuador.
| | - David Rivas-Lalaleo
- Departamento de Eléctrica y Electrónica, Universidad de las Fuerzas Armadas ESPE, Av. General Rumiñahui s/n, Sangolquí 171-5-231B, Ecuador.
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain.
| | - José Luis Rojo-Álvarez
- Departamento de Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, 28943 Fuenlabrada, Spain.
- Center for Computational Simulation, Universidad Politécnica de Madrid, Boadilla del Monte, 28660 Madrid, Spain.
| |
Collapse
|