1
|
García Flores FI, Klünder Klünder M, López Teros MT, Muñoz Ibañez CA, Padilla Castañeda MA. Development and Validation of a Method of Body Volume and Fat Mass Estimation Using Three-Dimensional Image Processing with a Mexican Sample. Nutrients 2024; 16:384. [PMID: 38337669 PMCID: PMC10856961 DOI: 10.3390/nu16030384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/12/2023] [Accepted: 12/27/2023] [Indexed: 02/12/2024] Open
Abstract
Body composition assessment using instruments such as dual X-ray densitometry (DXA) can be complex and their use is often limited to research. This cross-sectional study aimed to develop and validate a densitometric method for fat mass (FM) estimation using 3D cameras. Using two such cameras, stereographic images, and a mesh reconstruction algorithm, 3D models were obtained. The FM estimations were compared using DXA as a reference. In total, 28 adults, with a mean BMI of 24.5 (±3.7) kg/m2 and mean FM (by DXA) of 19.6 (±5.8) kg, were enrolled. The intraclass correlation coefficient (ICC) for body volume (BV) was 0.98-0.99 (95% CI, 0.97-0.99) for intra-observer and 0.98 (95% CI, 0.96-0.99) for inter-observer reliability. The coefficient of variation for kinetic BV was 0.20 and the mean difference (bias) for BV (liter) between Bod Pod and Kinect was 0.16 (95% CI, -1.2 to 1.6), while the limits of agreement (LoA) were 7.1 to -7.5 L. The mean bias for FM (kg) between DXA and Kinect was -0.29 (95% CI, -2.7 to 2.1), and the LoA was 12.1 to -12.7 kg. The adjusted R2 obtained using an FM regression model was 0.86. The measurements of this 3D camera-based system aligned with the reference measurements, showing the system's feasibility as a simpler, more economical screening tool than current systems.
Collapse
Affiliation(s)
| | - Miguel Klünder Klünder
- Research Subdirectorate, Children’s Hospital of Mexico Federico Gómez, Dr. Marquez St. 162, Colonia Doctores, Mexico City 06720, Mexico
| | - Miriam Teresa López Teros
- Health Department, Santa Fe Campus, Iberoamerican University, Prol. Paseo de la Reforma, Zedec Sta Fé, Álvaro Obregón, Mexico City 01219, Mexico;
| | - Cristopher Antonio Muñoz Ibañez
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnológico de Monterrey, Canal de Miramontes, Tlalpan, Mexico City 14380, Mexico;
| | - Miguel Angel Padilla Castañeda
- Applied Science and Technology Institute (ICAT), National Autonomous University of Mexico (UNAM), Mexico City 04510, Mexico
| |
Collapse
|
2
|
Wong MC, Bennett JP, Quon B, Leong LT, Tian IY, Liu YE, Kelly NN, McCarthy C, Chow D, Pujades S, Garber AK, Maskarinec G, Heymsfield SB, Shepherd JA. Accuracy and Precision of 3-dimensional Optical Imaging for Body Composition by Age, BMI, and Ethnicity. Am J Clin Nutr 2023; 118:657-671. [PMID: 37474106 PMCID: PMC10517211 DOI: 10.1016/j.ajcnut.2023.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 07/03/2023] [Accepted: 07/13/2023] [Indexed: 07/22/2023] Open
Abstract
BACKGROUND The obesity epidemic brought a need for accessible methods to monitor body composition, as excess adiposity has been associated with cardiovascular disease, metabolic disorders, and some cancers. Recent 3-dimensional optical (3DO) imaging advancements have provided opportunities for assessing body composition. However, the accuracy and precision of an overall 3DO body composition model in specific subgroups are unknown. OBJECTIVES This study aimed to evaluate 3DO's accuracy and precision by subgroups of age, body mass index, and ethnicity. METHODS A cross-sectional analysis was performed using data from the Shape Up! Adults study. Each participant received duplicate 3DO and dual-energy X-ray absorptiometry (DXA) scans. 3DO meshes were digitally registered and reposed using Meshcapade. Principal component analysis was performed on 3DO meshes. The resulting principal components estimated DXA whole-body and regional body composition using stepwise forward linear regression with 5-fold cross-validation. Duplicate 3DO and DXA scans were used for test-retest precision. Student's t tests were performed between 3DO and DXA by subgroup to determine significant differences. RESULTS Six hundred thirty-four participants (females = 346) had completed the study at the time of the analysis. 3DO total fat mass in the entire sample achieved R2 of 0.94 with root mean squared error (RMSE) of 2.91 kg compared to DXA in females and similarly in males. 3DO total fat mass achieved a % coefficient of variation (RMSE) of 1.76% (0.44 kg), whereas DXA was 0.98% (0.24 kg) in females and similarly in males. There were no mean differences for total fat, fat-free, percent fat, or visceral adipose tissue by age group (P > 0.068). However, there were mean differences for underweight, Asian, and Black females as well as Native Hawaiian or other Pacific Islanders (P < 0.038). CONCLUSIONS A single 3DO body composition model produced accurate and precise body composition estimates that can be used on diverse populations. However, adjustments to specific subgroups may be warranted to improve the accuracy in those that had significant differences. This trial was registered at clinicaltrials.gov as NCT03637855 (Shape Up! Adults).
Collapse
Affiliation(s)
- Michael C Wong
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States; Department of Human Nutrition, Food and Animal Sciences, University of Hawaii at Manoa, Honolulu, HI, United States
| | - Jonathan P Bennett
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States; Department of Human Nutrition, Food and Animal Sciences, University of Hawaii at Manoa, Honolulu, HI, United States
| | - Brandon Quon
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States
| | - Lambert T Leong
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States
| | - Isaac Y Tian
- Paul G. Allen School of Computer Science and Engineering, University of Washington, Seattle, WA, United States
| | - Yong E Liu
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States
| | - Nisa N Kelly
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States
| | - Cassidy McCarthy
- Pennington Biomedical Research Center, Baton Rouge, LA, United States
| | - Dominic Chow
- John A. Burns School of Medicine, University of Hawaii at Manoa, Honolulu, HI, United States
| | - Sergi Pujades
- Inria, Université Grenoble Alpes, CNRS, Grenoble INP, LJK, Grenoble, France
| | - Andrea K Garber
- Department of Pediatrics, University of California San Francisco, San Francisco, CA, United States
| | - Gertraud Maskarinec
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States
| | | | - John A Shepherd
- Department of Epidemiology, University of Hawaii Cancer Center, Honolulu, HI, United States; Department of Human Nutrition, Food and Animal Sciences, University of Hawaii at Manoa, Honolulu, HI, United States.
| |
Collapse
|
3
|
Londoño S, Viloria C, Pérez-Buitrago S, Murillo J, Botina D, Zarzycki A, Garzón J, Torres-Madronero MC, Robledo SM, Marzani F, Treuillet S, Castaneda B, Galeano J. Temporal Evaluation of the Surface Area of Treated Skin Ulcers Caused by Cutaneous Leishmaniasis and Relation with Optical Parameters in an Animal Model: A Proof of Concept. SENSORS (BASEL, SWITZERLAND) 2023; 23:5861. [PMID: 37447709 DOI: 10.3390/s23135861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 06/15/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
Abstract
Cutaneous leishmaniasis (CL) is a neglected disease caused by an intracellular parasite of the Leishmania genus. CL lacks tools that allow its understanding and treatment follow-up. This article presents the use of metrical and optical tools for the analysis of the temporal evolution of treated skin ulcers caused by CL in an animal model. Leishmania braziliensis and L. panamensis were experimentally inoculated in golden hamsters, which were treated with experimental and commercial drugs. The temporal evolution was monitored by means of ulcers' surface areas, as well as absorption and scattering optical parameters. Ulcers' surface areas were obtained via photogrammetry, which is a procedure that allowed for 3D modeling of the ulcer using specialized software. Optical parameters were obtained from a spectroscopy study, representing the cutaneous tissue's biological components. A one-way ANOVA analysis was conducted to identify relationships between both the ulcers' areas and optical parameters. As a result, ulcers' surface areas were found to be related to the following optical parameters: epidermis thickness, collagen, keratinocytes, volume-fraction of blood, and oxygen saturation. This study is a proof of concept that shows that optical parameters could be associated with metrical ones, giving a more reliable concept during the assessment of a skin ulcer's healing.
Collapse
Affiliation(s)
- Sergio Londoño
- Grupo de Investigación e Innovación Biomédica, Instituto Tecnológico Metropolitano, Medellín 050034, Colombia
| | - Carolina Viloria
- Grupo de Investigación e Innovación Biomédica, Instituto Tecnológico Metropolitano, Medellín 050034, Colombia
| | - Sandra Pérez-Buitrago
- Grupo de Investigación en Dispositivos Médicos, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima 15088, Peru
| | - Javier Murillo
- Programa de Estudio y Control de Enfermedades Tropicales-PECET, Facultad de Medicina, Universidad de Antioquia, Medellín 050010, Colombia
| | - Deivid Botina
- Laboratoire ImViA, Université de Bourgogne, BP 47870, 21078 Dijon Cedex, France
| | | | - Johnson Garzón
- Grupo de Óptica y Espectroscopía, Universidad Pontificia Bolivariana, Medellín 050031, Colombia
| | - Maria C Torres-Madronero
- Research Group on Smart Machine and Pattern Recognition, MIRP Laboratory, Instituto Tecnológico Metropolitano, Medellín 050013, Colombia
| | - Sara M Robledo
- Programa de Estudio y Control de Enfermedades Tropicales-PECET, Facultad de Medicina, Universidad de Antioquia, Medellín 050010, Colombia
| | - Franck Marzani
- Laboratoire ImViA, Université de Bourgogne, BP 47870, 21078 Dijon Cedex, France
| | - Sylvie Treuillet
- Laboratoire Pluridisciplinaire de Recherche Ingénierie des Systèmes, Mécanique, Énergétique-PRISME, Université d'Orléans, 45072 Orléans, France
| | - Benjamin Castaneda
- Grupo de Investigación en Dispositivos Médicos, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, Lima 15088, Peru
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14620, USA
| | - July Galeano
- Grupo de Investigación Materiales Avanzados y Energía MatyEr, Instituto Tecnológico Metropolitano, Medellín 050013, Colombia
| |
Collapse
|
4
|
Trojnacki M, Dąbek P, Jaroszek P. Mechatronic Design and Experimental Research of an Automated Photogrammetry-Based Human Body Scanner. SENSORS (BASEL, SWITZERLAND) 2023; 23:5840. [PMID: 37447690 DOI: 10.3390/s23135840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 06/05/2023] [Accepted: 06/21/2023] [Indexed: 07/15/2023]
Abstract
The article concerns the mechatronic design and experimental investigations of the HUBO automated human body scanning system. Functional problems that should be solved by using the developed scanning system are defined. These include reducing the number of sensors used while eliminating the need to rotate a human and ensuring the automation of the scanning process. Research problems that should be the subject of experimental research are defined. The current state of the art in the field of systems and techniques for scanning the human figure is described. The functional and technical assumptions for the HUBO scanning system are formulated. The mechanical design of the scanner, the hardware and information system architectures as well as the user's mobile application are presented. The method of operation of the scanning system and its innovative features are discussed. It is demonstrated that the developed solution of the scanning system allows the identified problems to be overcome. The methodology of the experimental research of the scanning system based on the photogrammetry technique is described. The results of laboratory studies with the use of dummies and experimental research with human participation are presented. The scope of the research carried out allows answers to the identified research problems related to the scanning of the human figure using the photogrammetry technique to be obtained. As part of laboratory tests using a measuring dummy, a mean error of 0.65 mm and standard deviation of the mean of 0.65 mm were obtained for the best scanner configuration. Research with human participation was carried out for the scanner version, in which the scanning time was 30 s, with the possibility of its reduction to 15 s. The results of studies using realistic dummies and with human participation were compared using the root mean square error parameter (RMSE) provided by the AliceVision framework, which was available for all analyzed objects. As a result, it was observed that these results are comparable, i.e., the RMSE parameter is equal to about 1 px.
Collapse
Affiliation(s)
| | - Przemysław Dąbek
- ŁUKASIEWICZ Research Network-Industrial Research Institute for Automation and Measurements PIAP, Al. Jerozolimskie 202, 02-486 Warsaw, Poland
| | | |
Collapse
|
5
|
Jasińska A, Pyka K, Pastucha E, Midtiby HS. A Simple Way to Reduce 3D Model Deformation in Smartphone Photogrammetry. SENSORS (BASEL, SWITZERLAND) 2023; 23:728. [PMID: 36679525 PMCID: PMC9860635 DOI: 10.3390/s23020728] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/03/2023] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
Recently, the term smartphone photogrammetry gained popularity. This suggests that photogrammetry may become a simple measurement tool by virtually every smartphone user. The research was undertaken to clarify whether it is appropriate to use the Structure from Motion-Multi Stereo View (SfM-MVS) procedure with self-calibration as it is done in Uncrewed Aerial Vehicle photogrammetry. First, the geometric stability of smartphone cameras was tested. Fourteen smartphones were calibrated on the checkerboard test field. The process was repeated multiple times. These observations were found: (1) most smartphone cameras have lower stability of the internal orientation parameters than a Digital Single-Lens Reflex (DSLR) camera, and (2) the principal distance and position of the principal point are constantly changing. Then, based on images from two selected smartphones, 3D models of a small sculpture were developed. The SfM-MVS method was used, with self-calibration and pre-calibration variants. By comparing the resultant models with the reference DSLR-created model it was shown that introducing calibration obtained in the test field instead of self-calibration improves the geometry of 3D models. In particular, deformations of local concavities and convexities decreased. In conclusion, there is real potential in smartphone photogrammetry, but it also has its limits.
Collapse
Affiliation(s)
- Aleksandra Jasińska
- Faculty of Geo-Data Science, Geodesy, and Environmental Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Cracow, Poland
| | - Krystian Pyka
- Faculty of Geo-Data Science, Geodesy, and Environmental Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Cracow, Poland
| | - Elżbieta Pastucha
- UAS Center, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Campusvey 55, 5230 Odense, Denmark
| | - Henrik Skov Midtiby
- UAS Center, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Campusvey 55, 5230 Odense, Denmark
| |
Collapse
|
6
|
Trojnacki M, Dąbek P, Jaroszek P. Analysis of the Influence of the Geometrical Parameters of the Body Scanner on the Accuracy of Reconstruction of the Human Figure Using the Photogrammetry Technique. SENSORS (BASEL, SWITZERLAND) 2022; 22:9181. [PMID: 36501882 PMCID: PMC9739902 DOI: 10.3390/s22239181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 06/17/2023]
Abstract
This article concerns the research of the HUBO full-body scanner, which includes the analysis and selection of the scanner's geometrical parameters in order to obtain the highest possible accuracy of the reconstruction of a human figure. In the scanner version analyzed in this paper, smartphone cameras are used as sensors. In order to process the collected photos into a 3D model, the photogrammetry technique is applied. As part of the work, dependencies between the geometrical parameters of the scanner are derived, which allows to significantly reduce the number of degrees of freedom in the selection of its geometrical parameters. Based on these dependencies, a numerical analysis is carried out, as a result of which the initial values of the geometrical parameters are pre-selected and distribution of scanner cameras is visualized. As part of the experimental research, the influence of selected scanner parameters on the scanning accuracy is analyzed. For the experimental research, a specially prepared dummy was used instead of the participation of a real human, which allowed to ensure the constancy of the scanned object. The accuracy of the object reconstruction was assessed in relation to the reference 3D model obtained with a scanner of superior measurement uncertainty. On the basis of the conducted research, a method for the selection of the scanner's geometrical parameters was finally verified, leading to the arrangement of cameras around a human, which guarantees high accuracy of the reconstruction. Additionally, to quantify the results, the quality rates were used, taking into account not only the obtained measurement uncertainty of the scanner, but also the processing time and the resulting efficiency.
Collapse
Affiliation(s)
| | - Przemysław Dąbek
- ŁUKASIEWICZ Research Network—Industrial Research Institute for Automation and Measurements PIAP, Al. Jerozolimskie 202, 02-486 Warsaw, Poland
| | | |
Collapse
|
7
|
Yang L, Guo X, Song X, Lu D, Cai W, Xiong Z. An Improved Human-Body-Segmentation Algorithm with Attention-Based Feature Fusion and a Refined Stereo-Matching Scheme Working at the Sub-Pixel Level for the Anthropometric System. ENTROPY (BASEL, SWITZERLAND) 2022; 24:1647. [PMID: 36421502 PMCID: PMC9689509 DOI: 10.3390/e24111647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/07/2022] [Accepted: 11/11/2022] [Indexed: 06/16/2023]
Abstract
This paper proposes an improved human-body-segmentation algorithm with attention-based feature fusion and a refined corner-based feature-point design with sub-pixel stereo matching for the anthropometric system. In the human-body-segmentation algorithm, four CBAMs are embedded in the four middle convolution layers of the backbone network (ResNet101) of PSPNet to achieve better feature fusion in space and channels, so as to improve accuracy. The common convolution in the residual blocks of ResNet101 is substituted by group convolution to reduce model parameters and computational cost, thereby optimizing efficiency. For the stereo-matching scheme, a corner-based feature point is designed to obtain the feature-point coordinates at sub-pixel level, so that precision is refined. A regional constraint is applied according to the characteristic of the checkerboard corner points, thereby reducing complexity. Experimental results demonstrated that the anthropometric system with the proposed CBAM-based human-body-segmentation algorithm and corner-based stereo-matching scheme can significantly outperform the state-of-the-art system in accuracy. It can also meet the national standards GB/T 2664-2017, GA 258-2009 and GB/T 2665-2017; and the textile industry standards FZ/T 73029-2019, FZ/T 73017-2014, FZ/T 73059-2017 and FZ/T 73022-2019.
Collapse
Affiliation(s)
- Lei Yang
- School of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Xiaoyu Guo
- School of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Xiaowei Song
- School of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 450007, China
- Dongjing Avenue Campus, Kaifeng University, Kaifeng 475004, China
| | - Deyuan Lu
- School of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Wenjing Cai
- School of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Zixiang Xiong
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|