1
|
Abideen ZU, Arifeen WU, Bandara YMNDY. Emerging trends in metal oxide-based electronic noses for healthcare applications: a review. NANOSCALE 2024; 16:9259-9283. [PMID: 38680123 DOI: 10.1039/d4nr00073k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
An electronic nose (E-nose) is a technology fundamentally inspired by the human nose, designed to detect, recognize, and differentiate specific odors or volatile components in complex and chaotic environments. Comprising an array of sensors with meticulously designed nanostructured architectures, E-noses translate the chemical information captured by these sensors into useful metrics using complex pattern recognition algorithms. E-noses can significantly enhance the quality of life by offering preventive point-of-care devices for medical diagnostics through breath analysis, and by monitoring and tracking hazardous and toxic gases in the environment. They are increasingly being used in defense and surveillance, medical diagnostics, agriculture, environmental monitoring, and product validation and authentication. The major challenge in developing a reliable E-nose involves miniaturization and low power consumption. Various sensing materials are employed to address these issues. This review presents the key advancements over the last decade in E-nose technology, specifically focusing on chemiresistive metal oxide sensing materials. It discusses their sensing mechanisms, integration into portable E-noses, and various data analysis techniques. Additionally, we review the primary metal oxide-based E-noses for disease detection through breath analysis. Finally, we address the major challenges and issues in developing and implementing a portable metal oxide-based E-nose.
Collapse
Affiliation(s)
- Zain Ul Abideen
- Nanotechnology Research Laboratory, Research School of Chemistry, College of Science, Australian National University, Canberra, ACT, 2601, Australia.
| | - Waqas Ul Arifeen
- School of Mechanical Engineering, Yeungnam University, Daehak-ro, Gyeongsan-si, Gyeongbuk-do, 38541, South Korea
| | - Y M Nuwan D Y Bandara
- Nanotechnology Research Laboratory, Research School of Chemistry, College of Science, Australian National University, Canberra, ACT, 2601, Australia.
| |
Collapse
|
2
|
Ali AS, Jacinto JGP, Mϋnchemyer W, Walte A, Kuhla B, Gentile A, Abdu MS, Kamel MM, Ghallab AM. Study on the Discrimination of Possible Error Sources That Might Affect the Quality of Volatile Organic Compounds Signature in Dairy Cattle Using an Electronic Nose. Vet Sci 2022; 9:vetsci9090461. [PMID: 36136677 PMCID: PMC9502780 DOI: 10.3390/vetsci9090461] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/12/2022] [Accepted: 08/23/2022] [Indexed: 11/25/2022] Open
Abstract
Simple Summary In recent decades, remarkable progress in the development of electronic nose (EN) technologies, particularly for disease detection, has been accomplished through the disclosure of novel methods and associated devices, mainly for the detection of volatile organic compounds (VOCs). Herein, we assessed the ability of a novel EN technology (MENT-EGAS prototype) to respond to direct sampling and to evaluate the influence of possible error sources that might affect the quality of VOC signatures. Principal Component Analyses (PCA) evidenced the presence in the analyzed samples of sufficient information to consent the discrimination of different environmental backgrounds, feed headspaces and exhalated breath between two groups of cows fed with two different types of feed. Moreover, discrimination was also observed within the same group between exhalated breaths sampled before and after feed intake. Based on these findings, we provided evidence that the MENT-EGAS prototype can identify error sources with accuracy. Livestock precision farming technologies are powerful tools for monitoring animal health and welfare parameters in a continuous and automated way. Abstract Electronic nose devices (EN) have been developed for detecting volatile organic compounds (VOCs). This study aimed to assess the ability of the MENT-EGAS prototype-based EN to respond to direct sampling and to evaluate the influence of possible error sources that might affect the quality of VOC signatures. This study was performed on a dairy farm using 11 (n = 11) multiparous Holstein-Friesian cows. The cows were divided into two groups housed in two different barns: group I included six lactating cows fed with a lactating diet (LD), and group II included 5 non-lactating late pregnant cows fed with a far-off diet (FD). Each group was offered 250 g of their respective diet; 10 min later, exhalated breath was collected for VOC determination. After this sampling, 4 cows from each group were offered 250 g of pellet concentrates. Ten minutes later, the exhalated breath was collected once more. VOCs were also measured directly from the feed’s headspace, as well as from the environmental backgrounds of each. Principal component analyses (PCA) were performed and revealed clear discrimination between the two different environmental backgrounds, the two different feed headspaces, the exhalated breath of groups I and II cows, and the exhalated breath within the same group of cows before and after the feed intake. Based on these findings, we concluded that the MENT-EGAS prototype can recognize several error sources with accuracy, providing a novel EN technology that could be used in the future in precision livestock farming.
Collapse
Affiliation(s)
- Asmaa S. Ali
- Department of Theriogenology, Faculty of Veterinary Medicine, Cairo University, Giza P.O. Box 12211, Egypt
- Correspondence:
| | - Joana G. P. Jacinto
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell’Emilia, 40064 Bologna, Italy
| | | | | | - Björn Kuhla
- Research Institute for Farm Animal Biology (FBN), Institute of Nutritional Physiology ‘Oskar Kellner’, 18196 Dummerstorf, Germany
| | - Arcangelo Gentile
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell’Emilia, 40064 Bologna, Italy
| | - Mohamed S. Abdu
- Department of Theriogenology, Faculty of Veterinary Medicine, Cairo University, Giza P.O. Box 12211, Egypt
| | - Mervat M. Kamel
- Department of Animal Management and Behavior, Faculty of Veterinary Medicine, Cairo University, Giza P.O. Box 12211, Egypt
| | - Abdelrauf Morsy Ghallab
- Department of Theriogenology, Faculty of Veterinary Medicine, Cairo University, Giza P.O. Box 12211, Egypt
| |
Collapse
|
3
|
Research on Micro-Fault Detection and Multiple-Fault Isolation for Gas Sensor Arrays Based on Serial Principal Component Analysis. ELECTRONICS 2022. [DOI: 10.3390/electronics11111755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Machine learning algorithms play an important role in fault detection and fault diagnosis of gas sensor arrays. Because the gas sensor array will see stability degradation and a shift in output signal amplitude under long-term operation, it is very important to detect the abnormal output signal of the gas sensor array in time and achieve accurate fault location. In order to solve the problem of low detection accuracy of micro-faults in gas sensor arrays, this paper adopts the serial principal component analysis (SPCA) method, which combines the advantages of principal component analysis (PCA) in the linear part and the advantages of kernel principal component analysis (KPCA) in the nonlinear part. The experimental results show that this method is more sensitive to micro-faults and has better fault detection accuracy than the fault detection methods of PCA and KPCA. In addition, in order to solve the current problem of low accuracy of multiple-fault isolation, a SPCA-based reconstruction contribution fault isolation method is proposed in this paper. The experimental results show that this method has higher fault isolation accuracy than the method based on contribution graph.
Collapse
|
4
|
Meléndez F, Arroyo P, Gómez-Suárez J, Palomeque-Mangut S, Suárez JI, Lozano J. Portable Electronic Nose Based on Digital and Analog Chemical Sensors for 2,4,6-Trichloroanisole Discrimination. SENSORS (BASEL, SWITZERLAND) 2022; 22:3453. [PMID: 35591143 PMCID: PMC9102965 DOI: 10.3390/s22093453] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/25/2022] [Accepted: 04/28/2022] [Indexed: 06/15/2023]
Abstract
2,4,6-trichloroanisole (TCA) is mainly responsible for cork taint in wine, which causes significant economic losses; therefore, the wine and cork industries demand an immediate, economic, noninvasive and on-the-spot solution. In this work, we present a novel prototype of an electronic nose (e-nose) using an array of digital and analog metal-oxide gas sensors with a total of 31 signals, capable of detecting TCA, and classifying cork samples with low TCA concentrations (≤15.1 ng/L). The results show that the device responds to low concentrations of TCA in laboratory conditions. It also differentiates among the inner and outer layers of cork bark (81.5% success) and distinguishes among six different samples of granulated cork (83.3% success). Finally, the device can predict the concentration of a new sample within a ±10% error margin.
Collapse
|
5
|
Assessing over Time Performance of an eNose Composed of 16 Single-Type MOX Gas Sensors Applied to Classify Two Volatiles. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10030118] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
This paper assesses the over time performance of a custom electronic nose (eNose) composed of an array of commercial low-cost and single-type miniature metal-oxide (MOX) semiconductor gas sensors. The eNose uses 16 BME680 versatile sensor devices, each including an embedded non-selective MOX gas sensor that was originally proposed to measure the total volatile organic compounds (TVOC) in the air. This custom eNose has been used previously to detect ethanol and acetone, obtaining initial promising classification results that worsened over time because of sensor drift. The current paper assesses the over time performance of different classification methods applied to process the information gathered from the eNose. The best classification results have been obtained when applying a linear discriminant analysis (LDA) to the normalized conductance of the sensing layer of the 16 MOX gas sensors available in the eNose. The LDA procedure by itself has reduced the influence of drift in the classification performance of this single-type eNose during an evaluation period of three months.
Collapse
|
6
|
Palacín J, Rubies E, Clotet E, Martínez D. Classification of Two Volatiles Using an eNose Composed by an Array of 16 Single-Type Miniature Micro-Machined Metal-Oxide Gas Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22031120. [PMID: 35161866 PMCID: PMC8838111 DOI: 10.3390/s22031120] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 01/19/2022] [Accepted: 01/27/2022] [Indexed: 05/26/2023]
Abstract
The artificial replication of an olfactory system is currently an open problem. The development of a portable and low-cost artificial olfactory system, also called electronic nose or eNose, is usually based on the use of an array of different gas sensors types, sensitive to different target gases. Low-cost Metal-Oxide semiconductor (MOX) gas sensors are widely used in such arrays. MOX sensors are based on a thin layer of silicon oxide with embedded heaters that can operate at different temperature set points, which usually have the disadvantages of different volatile sensitivity in each individual sensor unit and also different crossed sensitivity to different volatiles (unspecificity). This paper presents and eNose composed by an array of 16 low-cost BME680 digital miniature sensors embedding a miniature MOX gas sensor proposed to unspecifically evaluate air quality. In this paper, the inherent variability and unspecificity that must be expected from the 16 embedded MOX gas sensors, combined with signal processing, are exploited to classify two target volatiles: ethanol and acetone. The proposed eNose reads the resistance of the sensing layer of the 16 embedded MOX gas sensors, applies PCA for dimensional reduction and k-NN for classification. The validation results have shown an instantaneous classification success higher than 94% two days after the calibration and higher than 70% two weeks after, so the majority classification of a sequence of measures has been always successful in laboratory conditions. These first validation results and the low-power consumption of the eNose (0.9 W) enables its future improvement and its use in portable and battery-operated applications.
Collapse
|
7
|
Paleczek A, Rydosz AM. Review of the algorithms used in exhaled breath analysis for the detection of diabetes. J Breath Res 2022; 16. [PMID: 34996056 DOI: 10.1088/1752-7163/ac4916] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 01/07/2022] [Indexed: 11/11/2022]
Abstract
Currently, intensive work is underway on the development of truly noninvasive medical diagnostic systems, including respiratory analysers based on the detection of biomarkers of several diseases including diabetes. In terms of diabetes, acetone is considered as a one of the potential biomarker, although is not the single one. Therefore, the selective detection is crucial. Most often, the analysers of exhaled breath are based on the utilization of several commercially available gas sensors or on specially designed and manufactured gas sensors to obtain the highest selectivity and sensitivity to diabetes biomarkers present in the exhaled air. An important part of each system are the algorithms that are trained to detect diabetes based on data obtained from sensor matrices. The prepared review of the literature showed that there are many limitations in the development of the versatile breath analyser, such as high metabolic variability between patients, but the results obtained by researchers using the algorithms described in this paper are very promising and most of them achieve over 90% accuracy in the detection of diabetes in exhaled air. This paper summarizes the results using various measurement systems, feature extraction and feature selection methods as well as algorithms such as Support Vector Machines, k-Nearest Neighbours and various variations of Neural Networks for the detection of diabetes in patient samples and simulated artificial breath samples.
Collapse
Affiliation(s)
- Anna Paleczek
- Institute of Electronics, AGH University of Science and Technology Faculty of Computer Science Electronics and Telecommunications, al. A. Mickiewicza 30, Krakow, 30-059, POLAND
| | - Artur Maciej Rydosz
- Institute of Electronics, AGH University of Science and Technology Faculty of Computer Science Electronics and Telecommunications, Al. Mickiewicza 30, Krakow, 30-059, POLAND
| |
Collapse
|
8
|
Recent Progress in Smart Electronic Nose Technologies Enabled with Machine Learning Methods. SENSORS 2021; 21:s21227620. [PMID: 34833693 PMCID: PMC8619411 DOI: 10.3390/s21227620] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 11/08/2021] [Accepted: 11/13/2021] [Indexed: 02/07/2023]
Abstract
Machine learning methods enable the electronic nose (E-Nose) for precise odor identification with both qualitative and quantitative analysis. Advanced machine learning methods are crucial for the E-Nose to gain high performance and strengthen its capability in many applications, including robotics, food engineering, environment monitoring, and medical diagnosis. Recently, many machine learning techniques have been studied, developed, and integrated into feature extraction, modeling, and gas sensor drift compensation. The purpose of feature extraction is to keep robust pattern information in raw signals while removing redundancy and noise. With the extracted feature, a proper modeling method can effectively use the information for prediction. In addition, drift compensation is adopted to relieve the model accuracy degradation due to the gas sensor drifting. These recent advances have significantly promoted the prediction accuracy and stability of the E-Nose. This review is engaged to provide a summary of recent progress in advanced machine learning methods in E-Nose technologies and give an insight into new research directions in feature extraction, modeling, and sensor drift compensation.
Collapse
|
9
|
Kwiatkowski A, Drozdowska K, Smulko J. Embedded gas sensing setup for air samples analysis. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:074102. [PMID: 34340402 DOI: 10.1063/5.0050445] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/07/2021] [Indexed: 06/13/2023]
Abstract
This paper describes a measurement setup (eNose) designed to analyze air samples containing various volatile organic compounds (VOCs). The setup utilizes a set of resistive gas sensors of divergent gas selectivity and sensitivity. Some of the applied sensors are commercially available and were proposed recently to reduce their consumed energy. The sensors detect various VOCs at sensitivities determined by metal oxide sensors' technology and operating conditions. The setup can utilize prototype gas sensors, made of resistive layers of different compositions, as well. Their properties can be modulated by selecting operating temperature or using UV light irradiation. The unit is controlled by an embedded system M5Stack Core2 ESP32 IoT. We used this development kit to program the measurement procedure and data recording fastly. The setup utilizes an aluminum gas chamber of a volume of 220 ml, a set of electrical valves to introduce there an air sample with the help of an electrical micropump. The handling of the setup was simplified to a selection of a few operations by touch screen only without a necessity of extra training. The recorded data are saved in a memory card for further processing. The evolved setup can be upgraded to apply more advanced data processing by utilizing WiFi or Bluetooth connection. The control program was prepared using the Arduino IDE software environment and can be further advanced with ease. The applied materials and the established measurement procedure can use various air samples, including exhaled breath samples for patients' screening check-ups. We applied the same time of 10 min for response and recovery, acceptable for practical use.
Collapse
Affiliation(s)
- Andrzej Kwiatkowski
- Faculty of Electronics, Telecommunications and Informatics, and Digital Technologies Center, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
| | - Katarzyna Drozdowska
- Faculty of Electronics, Telecommunications and Informatics, and Digital Technologies Center, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
| | - Janusz Smulko
- Faculty of Electronics, Telecommunications and Informatics, and Digital Technologies Center, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
| |
Collapse
|
10
|
Kim S, Brady J, Al-Badani F, Yu S, Hart J, Jung S, Tran TT, Myung NV. Nanoengineering Approaches Toward Artificial Nose. Front Chem 2021; 9:629329. [PMID: 33681147 PMCID: PMC7935515 DOI: 10.3389/fchem.2021.629329] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Accepted: 01/05/2021] [Indexed: 12/16/2022] Open
Abstract
Significant scientific efforts have been made to mimic and potentially supersede the mammalian nose using artificial noses based on arrays of individual cross-sensitive gas sensors over the past couple decades. To this end, thousands of research articles have been published regarding the design of gas sensor arrays to function as artificial noses. Nanoengineered materials possessing high surface area for enhanced reaction kinetics and uniquely tunable optical, electronic, and optoelectronic properties have been extensively used as gas sensing materials in single gas sensors and sensor arrays. Therefore, nanoengineered materials address some of the shortcomings in sensitivity and selectivity inherent in microscale and macroscale materials for chemical sensors. In this article, the fundamental gas sensing mechanisms are briefly reviewed for each material class and sensing modality (electrical, optical, optoelectronic), followed by a survey and review of the various strategies for engineering or functionalizing these nanomaterials to improve their gas sensing selectivity, sensitivity and other measures of gas sensing performance. Specifically, one major focus of this review is on nanoscale materials and nanoengineering approaches for semiconducting metal oxides, transition metal dichalcogenides, carbonaceous nanomaterials, conducting polymers, and others as used in single gas sensors or sensor arrays for electrical sensing modality. Additionally, this review discusses the various nano-enabled techniques and materials of optical gas detection modality, including photonic crystals, surface plasmonic sensing, and nanoscale waveguides. Strategies for improving or tuning the sensitivity and selectivity of materials toward different gases are given priority due to the importance of having cross-sensitivity and selectivity toward various analytes in designing an effective artificial nose. Furthermore, optoelectrical sensing, which has to date not served as a common sensing modality, is also reviewed to highlight potential research directions. We close with some perspective on the future development of artificial noses which utilize optical and electrical sensing modalities, with additional focus on the less researched optoelectronic sensing modality.
Collapse
Affiliation(s)
- Sanggon Kim
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Jacob Brady
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Faraj Al-Badani
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
| | - Sooyoun Yu
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Joseph Hart
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Sungyong Jung
- Department of Electrical Engineering, University of Texas at Arlington, Arlington, TX, United States
| | - Thien-Toan Tran
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - Nosang V. Myung
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, United States
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| |
Collapse
|
11
|
Durán Acevedo CM, Cuastumal Vasquez CA, Carrillo Gómez JK. Electronic nose dataset for COPD detection from smokers and healthy people through exhaled breath analysis. Data Brief 2021; 35:106767. [PMID: 33537382 PMCID: PMC7838708 DOI: 10.1016/j.dib.2021.106767] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/07/2021] [Accepted: 01/13/2021] [Indexed: 11/19/2022] Open
Abstract
This article presents a database which was obtained by acquiring measurements through a multisensory device called Electronic Nose (E-nose) based on a matrix of metal oxide sensors, in order to discriminate and classify a group of people affected by the respiratory disease Chronic Obstructive Pulmonary Disease (COPD), smokers and healthy control people through exhaled breath analysis. The database consists of 4 groups of measurements which were acquired through the E-nose system: 10 control samples (healthy people), 20 samples of people with COPD, 4 samples of smokers and 10 air samples, where in each group two samples of exhaled breath per person were acquired giving a total of 78 samples (40 from COPD, 20 from control, 8 from smokers and 10 from the air)
Collapse
|
12
|
Esfahani S, Tiele A, Agbroko SO, Covington JA. Development of a Tuneable NDIR Optical Electronic Nose. SENSORS 2020; 20:s20236875. [PMID: 33271862 PMCID: PMC7729477 DOI: 10.3390/s20236875] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 11/22/2020] [Accepted: 11/27/2020] [Indexed: 01/01/2023]
Abstract
Electronic nose (E-nose) technology provides an easy and inexpensive way to analyse chemical samples. In recent years, there has been increasing demand for E-noses in applications such as food safety, environmental monitoring and medical diagnostics. Currently, the majority of E-noses utilise an array of metal oxide (MOX) or conducting polymer (CP) gas sensors. However, these sensing technologies can suffer from sensor drift, poor repeatability and temperature and humidity effects. Optical gas sensors have the potential to overcome these issues. This paper reports on the development of an optical non-dispersive infrared (NDIR) E-nose, which consists of an array of four tuneable detectors, able to scan a range of wavelengths (3.1–10.5 μm). The functionality of the device was demonstrated in a series of experiments, involving gas rig tests for individual chemicals (CO2 and CH4), at different concentrations, and discriminating between chemical standards and complex mixtures. The optical gas sensor responses were shown to be linear to polynomial for different concentrations of CO2 and CH4. Good discrimination was achieved between sample groups. Optical E-nose technology therefore demonstrates significant potential as a portable and low-cost solution for a number of E-nose applications.
Collapse
|
13
|
Rebordão G, Palma SICJ, Roque ACA. Microfluidics in Gas Sensing and Artificial Olfaction. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5742. [PMID: 33050311 PMCID: PMC7601286 DOI: 10.3390/s20205742] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/02/2020] [Accepted: 10/07/2020] [Indexed: 12/24/2022]
Abstract
Rapid, real-time, and non-invasive identification of volatile organic compounds (VOCs) and gases is an increasingly relevant field, with applications in areas such as healthcare, agriculture, or industry. Ideal characteristics of VOC and gas sensing devices used for artificial olfaction include portability and affordability, low power consumption, fast response, high selectivity, and sensitivity. Microfluidics meets all these requirements and allows for in situ operation and small sample amounts, providing many advantages compared to conventional methods using sophisticated apparatus such as gas chromatography and mass spectrometry. This review covers the work accomplished so far regarding microfluidic devices for gas sensing and artificial olfaction. Systems utilizing electrical and optical transduction, as well as several system designs engineered throughout the years are summarized, and future perspectives in the field are discussed.
Collapse
Affiliation(s)
| | - Susana I. C. J. Palma
- UCIBIO, Chemistry Department, School of Science and Technology, NOVA University of Lisbon, Campus Caparica, 2829-516 Caparica, Portugal;
| | - Ana C. A. Roque
- UCIBIO, Chemistry Department, School of Science and Technology, NOVA University of Lisbon, Campus Caparica, 2829-516 Caparica, Portugal;
| |
Collapse
|
14
|
Dospinescu VM, Tiele A, Covington JA. Sniffing Out Urinary Tract Infection-Diagnosis Based on Volatile Organic Compounds and Smell Profile. BIOSENSORS 2020; 10:E83. [PMID: 32717983 PMCID: PMC7460005 DOI: 10.3390/bios10080083] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/19/2020] [Accepted: 07/20/2020] [Indexed: 02/08/2023]
Abstract
Current available methods for the clinical diagnosis of urinary tract infection (UTI) rely on a urine dipstick test or culturing of pathogens. The dipstick test is rapid (available in 1-2 min), but has a low positive predictive value, while culturing is time-consuming and delays diagnosis (24-72 h between sample collection and pathogen identification). Due to this delay, broad-spectrum antibiotics are often prescribed immediately. The over-prescription of antibiotics should be limited, in order to prevent the development of antimicrobial resistance. As a result, there is a growing need for alternative diagnostic tools. This paper reviews applications of chemical-analysis instruments, such as gas chromatography-mass spectrometry (GC-MS), selected ion flow tube mass spectrometry (SIFT-MS), ion mobility spectrometry (IMS), field asymmetric ion mobility spectrometry (FAIMS) and electronic noses (eNoses) used for the diagnosis of UTI. These methods analyse volatile organic compounds (VOCs) that emanate from the headspace of collected urine samples to identify the bacterial pathogen and even determine the causative agent's resistance to different antibiotics. There is great potential for these technologies to gain wide-spread and routine use in clinical settings, since the analysis can be automated, and test results can be available within minutes after sample collection. This could significantly reduce the necessity to prescribe broad-spectrum antibiotics and allow the faster and more effective use of narrow-spectrum antibiotics.
Collapse
Affiliation(s)
| | - Akira Tiele
- School of Engineering, University of Warwick, Coventry CV4 7AL, UK;
| | | |
Collapse
|