1
|
Gudigar A, Kadri NA, Raghavendra U, Samanth J, Maithri M, Inamdar MA, Prabhu MA, Hegde A, Salvi M, Yeong CH, Barua PD, Molinari F, Acharya UR. Automatic identification of hypertension and assessment of its secondary effects using artificial intelligence: A systematic review (2013-2023). Comput Biol Med 2024; 172:108207. [PMID: 38489986 DOI: 10.1016/j.compbiomed.2024.108207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 03/17/2024]
Abstract
Artificial Intelligence (AI) techniques are increasingly used in computer-aided diagnostic tools in medicine. These techniques can also help to identify Hypertension (HTN) in its early stage, as it is a global health issue. Automated HTN detection uses socio-demographic, clinical data, and physiological signals. Additionally, signs of secondary HTN can also be identified using various imaging modalities. This systematic review examines related work on automated HTN detection. We identify datasets, techniques, and classifiers used to develop AI models from clinical data, physiological signals, and fused data (a combination of both). Image-based models for assessing secondary HTN are also reviewed. The majority of the studies have primarily utilized single-modality approaches, such as biological signals (e.g., electrocardiography, photoplethysmography), and medical imaging (e.g., magnetic resonance angiography, ultrasound). Surprisingly, only a small portion of the studies (22 out of 122) utilized a multi-modal fusion approach combining data from different sources. Even fewer investigated integrating clinical data, physiological signals, and medical imaging to understand the intricate relationships between these factors. Future research directions are discussed that could build better healthcare systems for early HTN detection through more integrated modeling of multi-modal data sources.
Collapse
Affiliation(s)
- Anjan Gudigar
- Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Nahrizul Adib Kadri
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, 50603, Malaysia
| | - U Raghavendra
- Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India.
| | - Jyothi Samanth
- Department of Cardiovascular Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, 576104, India
| | - M Maithri
- Department of Mechatronics, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Mahesh Anil Inamdar
- Department of Mechatronics, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Mukund A Prabhu
- Department of Cardiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Ajay Hegde
- Manipal Hospitals, Bengaluru, Karnataka, 560102, India
| | - Massimo Salvi
- Biolab, PolitoBIOMedLab, Department of Electronics and Telecommunications, Politecnicodi Torino, Turin, Italy
| | - Chai Hong Yeong
- School of Medicine, Faculty of Health and Medical Sciences, Taylor's University, 47500, Subang Jaya, Malaysia
| | - Prabal Datta Barua
- Cogninet Brain Team, Cogninet Australia, Sydney, NSW, 2010, Australia; School of Business (Information Systems), Faculty of Business, Education, Law & Arts, University of Southern Queensland, Toowoomba, QLD, 4350, Australia; Faculty of Engineering and Information Technology, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Filippo Molinari
- Biolab, PolitoBIOMedLab, Department of Electronics and Telecommunications, Politecnicodi Torino, Turin, Italy
| | - U Rajendra Acharya
- School of Mathematics, Physics, and Computing, University of Southern Queensland, Springfield, QLD, 4300, Australia; Centre for Health Research, University of Southern Queensland, Toowoomba, QLD, 4350, Australia
| |
Collapse
|
2
|
Geng D, Yin Y, Fu Z, Pang G, Xu G, Geng Y, Wang A. Heart rate detection method based on Ballistocardiogram signal of wearable device:Algorithm development and validation. Heliyon 2024; 10:e27369. [PMID: 38486774 PMCID: PMC10937685 DOI: 10.1016/j.heliyon.2024.e27369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 02/27/2024] [Accepted: 02/28/2024] [Indexed: 03/17/2024] Open
Abstract
Background Heart rate, as the four vital signs of human body, is a basic indicator to measure a person's health status. Traditional electrocardiography (ECG) measurement, which is routinely monitored, requires subjects to wear lead electrodes frequently, which undoubtedly places great restrictions on participants' activities during the normal test. At present, the boom of wearable devices has created hope for non-invasive, simple operation and low-cost daily heart rate monitoring, among them, Ballistocardiogram signal (BCG) is an effective heart rate measurement method, but in the actual acquisition process, the robustness of non-invasive vital sign collection is limited. Therefore, it is necessary to develop a method to improve the robustness of heart rate monitoring. Objective Therefore, in view of the problem that the accuracy of untethered monitoring heart rate is not high, we propose a method aimed at detecting the heartbeat cycle based on BCG to accurately obtain the beat-to-beat heart rate in the sleep state. Methods In this study, we implement an innovative J-wave detection algorithm based on BCG signals. By collecting BCG signals recorded by 28 healthy subjects in different sleeping positions, after preprocessing, the data feature set is formed according to the clustering of morphological features in the heartbeat interval. Finally, a J-wave recognition model is constructed based on bi-directional long short-term memory (BiLSTM), and then the number of J-waves in the input sequence is counted to realize real-time detection of heartbeat. The performance of the proposed heartbeat detection scheme is cross-verified, and the proposed method is compared with the previous wearable device algorithm. Results The accuracy of J wave recognition in BCG signal is 99.67%, and the deviation rate of heart rate detection is only 0.27%, which has higher accuracy than previous wearable device algorithms. To assess consistency between method results and heart rates obtained by the ECG, seven subjects are compared using Bland-Altman plots, which show no significant difference between BCG and ECG results for heartbeat cycles. Conclusions Compared with other studies, the proposed method is more accurate in J-wave recognition, which improves the accuracy and generalization ability of BCG-based continuous heartbeat cycle extraction, and provides preliminary support for wearable-based untethered daily monitoring.
Collapse
Affiliation(s)
- Duyan Geng
- Hebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China
- Hebei University of Technology, School of Electrical Engineering, Tianjin, 300130, PR China
| | - Yue Yin
- Hebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China
- Hebei University of Technology, School of Electrical Engineering, Tianjin, 300130, PR China
| | - Zhigang Fu
- Physical Examination Center of the Fourth Joint Logistics Support Unit of the 983rd Hospital of the Tianjin Chinese People's Liberation Army, Tianjin, 300142, PR China
| | - Geng Pang
- Hebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China
- Hebei University of Technology, School of Electrical Engineering, Tianjin, 300130, PR China
| | - Guizhi Xu
- Hebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China
- Hebei University of Technology, School of Electrical Engineering, Tianjin, 300130, PR China
| | - Yan Geng
- Hebei Institute for Drug and Medical Device Control, Shijiazhuang, 050200, PR China
| | - Alan Wang
- Centre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
- Centre for Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
3
|
Sharma M, Verma S, Anand D, Gadre VM, Acharya UR. CAPSCNet: A novel scattering network for automated identification of phasic cyclic alternating patterns of human sleep using multivariate EEG signals. Comput Biol Med 2023; 164:107259. [PMID: 37544251 DOI: 10.1016/j.compbiomed.2023.107259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 07/03/2023] [Accepted: 07/04/2023] [Indexed: 08/08/2023]
Abstract
The Cyclic Alternating Pattern (CAP) can be considered a physiological marker of sleep instability. The CAP can examine various sleep-related disorders. Certain short events (A and B phases) manifest related to a specific physiological process or pathology during non-rapid eye movement (NREM) sleep. These phases unexpectedly modify EEG oscillations; hence, manual detection is challenging. Therefore, it is highly desirable to have an automated system for detecting the A-phases (AP). Deep convolution neural networks (CNN) have shown high performance in various healthcare applications. A variant of the deep neural network called the Wavelet Scattering Network (WSN) has been used to overcome the specific limitations of CNN, such as the need for a large amount of data to train the model. WSN is an optimized network that can learn features that help discriminate patterns hidden inside signals. Also, WSNs are invariant to local perturbations, making the network significantly more reliable and effective. It can also help improve performance on tasks where data is minimal. In this study, we proposed a novel WSN-based CAPSCNet to automatically detect AP using EEG signals. Seven dataset variants of cyclic alternating pattern (CAP) sleep cohort is employed for this study. Two electroencephalograms (EEG) derivations, namely: C4-A1 and F4-C4, are used to develop the CAPSCNet. The model is examined using healthy subjects and patients tormented by six different sleep disorders, namely: sleep-disordered breathing (SDB), insomnia, nocturnal frontal lobe epilepsy (NFLE), narcolepsy, periodic leg movement disorder (PLM) and rapid eye movement behavior disorder (RBD) subjects. Several different machine-learning algorithms were used to classify the features obtained from the WSN. The proposed CAPSCNet has achieved the highest average classification accuracy of 83.4% using a trilayered neural network classifier for the healthy data variant. The proposed CAPSCNet is efficient and computationally faster.
Collapse
Affiliation(s)
- Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad, India.
| | - Sarv Verma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad, India.
| | - Divyansh Anand
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad, India.
| | - Vikram M Gadre
- Department of Electrical Engineering, Indian Institute of Technology, Bombay, Mumbai, India.
| | - U Rajendra Acharya
- School of Mathematics, Physics and Computing, University of Southern Queensland, Springfield 4300, Australia.
| |
Collapse
|
4
|
Ozcelik STA, Uyanık H, Deniz E, Sengur A. Automated Hypertension Detection Using ConvMixer and Spectrogram Techniques with Ballistocardiograph Signals. Diagnostics (Basel) 2023; 13:diagnostics13020182. [PMID: 36672992 PMCID: PMC9858153 DOI: 10.3390/diagnostics13020182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/01/2023] [Accepted: 01/03/2023] [Indexed: 01/06/2023] Open
Abstract
Blood pressure is the pressure exerted by the blood in the veins against the walls of the veins. If this value is above normal levels, it is known as high blood pressure (HBP) or hypertension (HPT). This health problem which often referred to as the "silent killer" reduces the quality of life and causes severe damage to many body parts in various ways. Besides, its mortality rate is very high. Hence, rapid and effective diagnosis of this health problem is crucial. In this study, an automatic diagnosis of HPT has been proposed using ballistocardiography (BCG) signals. The BCG signals were transformed to the time-frequency domain using the spectrogram method. While creating the spectrogram images, parameters such as window type, window length, overlapping rate, and fast Fourier transform size were adjusted. Then, these images were classified using ConvMixer architecture, similar to vision transformers (ViT) and multi-layer perceptron (MLP)-mixer structures, which have attracted a lot of attention. Its performance was compared with classical architectures such as ResNet18 and ResNet50. The results obtained showed that the ConvMixer structure gave very successful results and a very short operation time. Our proposed model has obtained an accuracy of 98.14%, 98.79%, and 97.69% for the ResNet18, ResNet50, and ConvMixer architectures, respectively. In addition, it has been observed that the processing time of the ConvMixer architecture is relatively short compared to these two architectures.
Collapse
Affiliation(s)
- Salih T. A. Ozcelik
- Electrical-Electronics Engineering Department, Engineering Faculty, Bingol University, Bingol 12000, Turkey
| | - Hakan Uyanık
- Electrical-Electronics Engineering Department, Engineering Faculty, Munzur University, Tunceli 62000, Turkey
| | - Erkan Deniz
- Electrical-Electronics Engineering Department, Technology Faculty, Firat University, Elazig 23119, Turkey
| | - Abdulkadir Sengur
- Electrical-Electronics Engineering Department, Technology Faculty, Firat University, Elazig 23119, Turkey
- Correspondence:
| |
Collapse
|
5
|
Fuadah YN, Lim KM. Classification of Blood Pressure Levels Based on Photoplethysmogram and Electrocardiogram Signals with a Concatenated Convolutional Neural Network. Diagnostics (Basel) 2022; 12:diagnostics12112886. [PMID: 36428946 PMCID: PMC9689744 DOI: 10.3390/diagnostics12112886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/04/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
Hypertension is a severe public health issue worldwide that significantly increases the risk of cardiac vascular disease, stroke, brain hemorrhage, and renal dysfunction. Early screening of blood pressure (BP) levels is essential to prevent the dangerous complication associated with hypertension as the leading cause of death. Recent studies have focused on employing photoplethysmograms (PPG) with machine learning to classify BP levels. However, several studies claimed that electrocardiograms (ECG) also strongly correlate with blood pressure. Therefore, we proposed a concatenated convolutional neural network which integrated the features extracted from PPG and ECG signals. This study used the MIMIC III dataset, which provided PPG, ECG, and arterial blood pressure (ABP) signals. A total of 14,298 signal segments were obtained from 221 patients, which were divided into 9150 signals of train data, 2288 signals of validation data, and 2860 signals of test data. In the training process, five-fold cross-validation was applied to select the best model with the highest classification performance. The proposed concatenated CNN architecture using PPG and ECG obtained the highest test accuracy of 94.56-95.15% with a 95% confidence interval in classifying BP levels into hypotension, normotension, prehypertension, hypertension stage 1, and hypertension stage 2. The result shows that the proposed method is a promising solution to categorize BP levels effectively, assisting medical personnel in making a clinical diagnosis.
Collapse
Affiliation(s)
- Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Correspondence:
| |
Collapse
|
6
|
Gupta K, Bajaj V, Ansari IA, Rajendra Acharya U. Hyp-Net: Automated detection of hypertension using deep convolutional neural network and Gabor transform techniques with ballistocardiogram signals. Biocybern Biomed Eng 2022. [DOI: 10.1016/j.bbe.2022.06.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
7
|
ECG signal based automated hypertension detection using fourier decomposition method and cosine modulated filter banks. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103629] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
8
|
Rajput JS, Sharma M, Kumar TS, Acharya UR. Automated Detection of Hypertension Using Continuous Wavelet Transform and a Deep Neural Network with Ballistocardiography Signals. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19074014. [PMID: 35409698 PMCID: PMC8997686 DOI: 10.3390/ijerph19074014] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 03/19/2022] [Accepted: 03/22/2022] [Indexed: 01/27/2023]
Abstract
Managing hypertension (HPT) remains a significant challenge for humanity. Despite advancements in blood pressure (BP)-measuring systems and the accessibility of effective and safe anti-hypertensive medicines, HPT is a major public health concern. Headaches, dizziness and fainting are common symptoms of HPT. In HPT patients, normalcy may be observed at one instant and abnormality may prevail during a long duration of 24 h ambulatory BP. This may cause difficulty in identifying patients with HPT, and hence there is a possibility that individuals may be untreated or administered insufficiently. Most importantly, uncontrolled HPT can lead to severe complications (stroke, heart attack, kidney disease, and heart failure), mainly ignoring the signs in nascent stages. HPT in the beginning stages may not present distinct symptoms and may be difficult to diagnose from standard physiological signals. Hence, ballistocardiography (BCG) signal was used in this study to detect HPT automatically. The processed signals from BCG were converted into scalogram images using a continuous wavelet transform (CWT) and were then fed into a 2-D convolutional neural network model (2D-CNN). The model was trained to learn and recognize BCG patterns of healthy controls (HC) and HPT classes. Our proposed model obtained a high classification accuracy of 86.14% with a ten-fold cross-validation (CV) strategy. Hence, this is the first use of a 2D-CNN model (deep-learning algorithm) to detect HPT employing BCG signals.
Collapse
Affiliation(s)
- Jaypal Singh Rajput
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India; (J.S.R.); (T.S.K.)
| | - Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India; (J.S.R.); (T.S.K.)
- Correspondence:
| | - T. Sudheer Kumar
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India; (J.S.R.); (T.S.K.)
| | - U. Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 639798, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
- Department of Biomedical Engineering, School of Science and Technology, Singapore 639798, Singapore
| |
Collapse
|
9
|
Martinez-Ríos E, Montesinos L, Alfaro-Ponce M, Pecchia L. A review of machine learning in hypertension detection and blood pressure estimation based on clinical and physiological data. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102813] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
10
|
Sharma M, Rajput JS, Tan RS, Acharya UR. Automated Detection of Hypertension Using Physiological Signals: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:5838. [PMID: 34072304 PMCID: PMC8198170 DOI: 10.3390/ijerph18115838] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/10/2021] [Accepted: 05/24/2021] [Indexed: 01/09/2023]
Abstract
Arterial hypertension (HT) is a chronic condition of elevated blood pressure (BP), which may cause increased incidence of cardiovascular disease, stroke, kidney failure and mortality. If the HT is diagnosed early, effective treatment can control the BP and avert adverse outcomes. Physiological signals like electrocardiography (ECG), photoplethysmography (PPG), heart rate variability (HRV), and ballistocardiography (BCG) can be used to monitor health status but are not directly correlated with BP measurements. The manual detection of HT using these physiological signals is time consuming and prone to human errors. Hence, many computer-aided diagnosis systems have been developed. This paper is a systematic review of studies conducted on the automated detection of HT using ECG, HRV, PPG and BCG signals. In this review, we have identified 23 studies out of 250 screened papers, which fulfilled our eligibility criteria. Details of the study methods, physiological signal studied, database used, various nonlinear techniques employed, feature extraction, and diagnostic performance parameters are discussed. The machine learning and deep learning based methods based on ECG and HRV signals have yielded the best performance and can be used for the development of computer-aided diagnosis of HT. This work provides insights that may be useful for the development of wearable for continuous cuffless remote monitoring of BP based on ECG and HRV signals.
Collapse
Affiliation(s)
- Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India;
| | - Jaypal Singh Rajput
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India;
| | - Ru San Tan
- National Heart Centre, Singapore 639798, Singapore;
| | - U. Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 639798, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
- Department of Biomedical Engineering, School of Science and Technology, SUSS, Singapore 599494, Singapore
| |
Collapse
|
11
|
Sharma M, Tiwari J, Acharya UR. Automatic Sleep-Stage Scoring in Healthy and Sleep Disorder Patients Using Optimal Wavelet Filter Bank Technique with EEG Signals. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:3087. [PMID: 33802799 PMCID: PMC8002569 DOI: 10.3390/ijerph18063087] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 03/04/2021] [Accepted: 03/05/2021] [Indexed: 01/20/2023]
Abstract
Sleep stage classification plays a pivotal role in effective diagnosis and treatment of sleep related disorders. Traditionally, sleep scoring is done manually by trained sleep scorers. The analysis of electroencephalogram (EEG) signals recorded during sleep by clinicians is tedious, time-consuming and prone to human errors. Therefore, it is clinically important to score sleep stages using machine learning techniques to get accurate diagnosis. Several studies have been proposed for automated detection of sleep stages. However, these studies have employed only healthy normal subjects (good sleepers). The proposed study focuses on the automated sleep-stage scoring of subjects suffering from seven different kind of sleep disorders such as insomnia, bruxism, narcolepsy, nocturnal frontal lobe epilepsy (NFLE), periodic leg movement (PLM), rapid eye movement (REM) behavioural disorder and sleep-disordered breathing as well as normal subjects. The open source physionet's cyclic alternating pattern (CAP) sleep database is used for this study. The EEG epochs are decomposed into sub-bands using a new class of optimized wavelet filters. Two EEG channels, namely F4-C4 and C4-A1, combined are used for this work as they can provide more insights into the changes in EEG signals during sleep. The norm features are computed from six sub-bands coefficients of optimal wavelet filter bank and fed to various supervised machine learning classifiers. We have obtained the highest classification performance using an ensemble of bagged tree (EBT) classifier with 10-fold cross validation. The CAP database comprising of 80 subjects is divided into ten different subsets and then ten different sleep-stage scoring tasks are performed. Since, the CAP database is unbalanced with different duration of sleep stages, the balanced dataset also has been created using over-sampling and under-sampling techniques. The highest average accuracy of 85.3% and Cohen's Kappa coefficient of 0.786 and accuracy of 92.8% and Cohen's Kappa coefficient of 0.915 are obtained for unbalanced and balanced databases, respectively. The proposed method can reliably classify the sleep stages using single or dual channel EEG epochs of 30 s duration instead of using multimodal polysomnography (PSG) which are generally used for sleep-stage scoring. Our developed automated system is ready to be tested with more sleep EEG data and can be employed in various sleep laboratories to evaluate the quality of sleep in various sleep disorder patients and normal subjects.
Collapse
Affiliation(s)
- Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad 380026, India;
| | - Jainendra Tiwari
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad 380026, India;
| | - U. Rajendra Acharya
- School of Engineering, Ngee Ann Polytechnic, Singapore 599489, Singapore;
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan
- School of Management and Enterprise, University of Southern Queensland, Springfield 4300, Australia
| |
Collapse
|
12
|
Sharma M, Acharya UR. Automated detection of schizophrenia using optimal wavelet-based l 1 norm features extracted from single-channel EEG. Cogn Neurodyn 2021; 15:661-674. [PMID: 34367367 DOI: 10.1007/s11571-020-09655-w] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 11/12/2020] [Accepted: 11/27/2020] [Indexed: 10/22/2022] Open
Abstract
Schizophrenia (SZ) is a mental disorder, which affects the ability of human thinking, memory, and way of living. Manual screening of SZ patients is tedious, laborious and prone to human errors. Hence, we developed a computer-aided diagnosis (CAD) system to diagnose SZ patients accurately using single-channel electroencephalogram (EEG) signals. The EEG signals are nonlinear and non-stationary. Hence, we have used wavelet-based features to capture the hidden non-stationary nature present in the signal. First, the EEG signals are subjected to the the wavelet decomposition through six iterations, which yields seven sub-bands. The l 1 norm is computed for each sub-band. The extracted norm features are disseminated to various classification algorithms. We have obtained the highest accuracy of 99.21% and 97.2% using K-nearest neighbor classifiers with ten-fold and leave-one-subject-out cross-validations. The developed single-channel EEG wavelet-based CAD model can help the clinicians to confirm the outcome of their manual screening and obtain an accurate diagnosis.
Collapse
Affiliation(s)
- Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad, India
| | - U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore, Singapore.,Department of Biomedical Engineering, School of Science and Technology, Singapore University of Social Sciences, Singapore, Singapore.,Department of Bioinformatics and Medical Engineering, Asia University, Taichung City, Taiwan, ROC
| |
Collapse
|
13
|
Khan MU, Aziz S, Akram T, Amjad F, Iqtidar K, Nam Y, Khan MA. Expert Hypertension Detection System Featuring Pulse Plethysmograph Signals and Hybrid Feature Selection and Reduction Scheme. SENSORS 2021; 21:s21010247. [PMID: 33401652 PMCID: PMC7794944 DOI: 10.3390/s21010247] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 12/22/2020] [Accepted: 12/24/2020] [Indexed: 12/27/2022]
Abstract
Hypertension is an antecedent to cardiac disorders. According to the World Health Organization (WHO), the number of people affected with hypertension will reach around 1.56 billion by 2025. Early detection of hypertension is imperative to prevent the complications caused by cardiac abnormalities. Hypertension usually possesses no apparent detectable symptoms; hence, the control rate is significantly low. Computer-aided diagnosis based on machine learning and signal analysis has recently been applied to identify biomarkers for the accurate prediction of hypertension. This research proposes a new expert hypertension detection system (EHDS) from pulse plethysmograph (PuPG) signals for the categorization of normal and hypertension. The PuPG signal data set, including rich information of cardiac activity, was acquired from healthy and hypertensive subjects. The raw PuPG signals were preprocessed through empirical mode decomposition (EMD) by decomposing a signal into its constituent components. A combination of multi-domain features was extracted from the preprocessed PuPG signal. The features exhibiting high discriminative characteristics were selected and reduced through a proposed hybrid feature selection and reduction (HFSR) scheme. Selected features were subjected to various classification methods in a comparative fashion in which the best performance of 99.4% accuracy, 99.6% sensitivity, and 99.2% specificity was achieved through weighted k-nearest neighbor (KNN-W). The performance of the proposed EHDS was thoroughly assessed by tenfold cross-validation. The proposed EHDS achieved better detection performance in comparison to other electrocardiogram (ECG) and photoplethysmograph (PPG)-based methods.
Collapse
Affiliation(s)
- Muhammad Umar Khan
- Department of Electronics Engineering, University of Engineering and Technology Taxila, Taxila 47050, Pakistan; (M.U.K.); (F.A.)
| | - Sumair Aziz
- Department of Electronics Engineering, University of Engineering and Technology Taxila, Taxila 47050, Pakistan; (M.U.K.); (F.A.)
- Correspondence: (S.A.); (Y.N.)
| | - Tallha Akram
- Department of Electrical and Computer Engineering, COMSATS University Islamabad, Wah Campus, Wah Cantonment, Islamabad 45550, Pakistan;
| | - Fatima Amjad
- Department of Electronics Engineering, University of Engineering and Technology Taxila, Taxila 47050, Pakistan; (M.U.K.); (F.A.)
| | - Khushbakht Iqtidar
- Department of Computer and Software Engineering, College of Electrical and Mechanical Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan;
| | - Yunyoung Nam
- Department of Computer Science and Engineering, Soonchunhyang University, Asan 31538, Korea
- Correspondence: (S.A.); (Y.N.)
| | | |
Collapse
|
14
|
Rajput JS, Sharma M, Kumbhani D, Acharya UR. Automated detection of hypertension using wavelet transform and nonlinear techniques with ballistocardiogram signals. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
15
|
Bird K, Chan G, Lu H, Greeff H, Allen J, Abbott D, Menon C, Lovell NH, Howard N, Chan WS, Fletcher RR, Alian A, Ward R, Elgendi M. Assessment of Hypertension Using Clinical Electrocardiogram Features: A First-Ever Review. Front Med (Lausanne) 2020; 7:583331. [PMID: 33344473 PMCID: PMC7746856 DOI: 10.3389/fmed.2020.583331] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/16/2020] [Indexed: 12/31/2022] Open
Abstract
Hypertension affects an estimated 1.4 billion people and is a major cause of morbidity and mortality worldwide. Early diagnosis and intervention can potentially decrease cardiovascular events later in life. However, blood pressure (BP) measurements take time and require training for health care professionals. The measurements are also inconvenient for patients to access, numerous daily variables affect BP values, and only a few BP readings can be collected per session. This leads to an unmet need for an accurate, 24-h continuous, and portable BP measurement system. Electrocardiograms (ECGs) have been considered as an alternative way to measure BP and may meet this need. This review summarizes the literature published from January 1, 2010, to January 1, 2020, on the use of only ECG wave morphology to monitor BP or identify hypertension. From 35 articles analyzed (9 of those with no listed comorbidities and confounders), the P wave, QTc intervals and TpTe intervals may be promising for this purpose. Unfortunately, with the limited number of articles and the variety of participant populations, we are unable to make conclusions about the effectiveness of ECG-only BP monitoring. We provide 13 recommendations for future ECG-only BP monitoring studies and highlight the limited findings in pregnant and pediatric populations. With the advent of convenient and portable ECG signal recording in smart devices and wearables such as watches, understanding how to apply ECG-only findings to identify hypertension early is crucial to improving health outcomes worldwide.
Collapse
Affiliation(s)
- Kathleen Bird
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Gabriel Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Huiqi Lu
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Heloise Greeff
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - John Allen
- Research Center for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
| | - Derek Abbott
- School of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA, Australia.,Center for Biomedical Engineering, The University of Adelaide, Adelaide, SA, Australia
| | - Carlo Menon
- School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC, Canada
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, NSW, Australia
| | - Newton Howard
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, United Kingdom
| | - Wee-Shian Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Richard Ribon Fletcher
- D-Lab, Massachusetts Institute of Technology, Cambridge, MA, United States.,Department of Psychiatry, University of Massachusetts Medical School, Worcester, MA, United States
| | - Aymen Alian
- Yale School of Medicine, Yale University, New Haven, CT, United States
| | - Rabab Ward
- School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
| | - Mohamed Elgendi
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.,School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC, Canada.,Nuffield Department of Surgical Sciences, University of Oxford, Oxford, United Kingdom.,School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada.,BC Children's & Women's Hospital, Vancouver, BC, Canada
| |
Collapse
|
16
|
Yildirim O, Talo M, Ciaccio EJ, Tan RS, Acharya UR. Accurate deep neural network model to detect cardiac arrhythmia on more than 10,000 individual subject ECG records. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105740. [PMID: 32932129 PMCID: PMC7477611 DOI: 10.1016/j.cmpb.2020.105740] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Accepted: 08/31/2020] [Indexed: 05/04/2023]
Abstract
BACKGROUND AND OBJECTIVE Cardiac arrhythmia, which is an abnormal heart rhythm, is a common clinical problem in cardiology. Detection of arrhythmia on an extended duration electrocardiogram (ECG) is done based on initial algorithmic software screening, with final visual validation by cardiologists. It is a time consuming and subjective process. Therefore, fully automated computer-assisted detection systems with a high degree of accuracy have an essential role in this task. In this study, we proposed an effective deep neural network (DNN) model to detect different rhythm classes from a new ECG database. METHODS Our DNN model was designed for high performance on all ECG leads. The proposed model, which included both representation learning and sequence learning tasks, showed promising results on all 12-lead inputs. Convolutional layers and sub-sampling layers were used in the representation learning phase. The sequence learning part involved a long short-term memory (LSTM) unit after representation of learning layers. RESULTS We performed two different class scenarios, including reduced rhythms (seven rhythm types) and merged rhythms (four rhythm types) according to the records from the database. Our trained DNN model achieved 92.24% and 96.13% accuracies for the reduced and merged rhythm classes, respectively. CONCLUSION Recently, deep learning algorithms have been found to be useful because of their high performance. The main challenge is the scarcity of appropriate training and testing resources because model performance is dependent on the quality and quantity of case samples. In this study, we used a new public arrhythmia database comprising more than 10,000 records. We constructed an efficient DNN model for automated detection of arrhythmia using these records.
Collapse
Affiliation(s)
- Ozal Yildirim
- Department of Computer Engineering, Munzur University, Tunceli,62000, Turkey
| | - Muhammed Talo
- Department of Software Engineering, Firat University, Elazig, Turkey
| | - Edward J Ciaccio
- Department of Medicine, Division of Cardiology, Columbia University Medical Center, New York, NY 10032, USA
| | - Ru San Tan
- National Heart Centre Singapore, Singapore; Duke-NUS Medical School, Singapore
| | - U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore; Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan; School of Management and Enterprise University of Southern Queensland, Springfield, Australia.
| |
Collapse
|
17
|
Soh DCK, Ng E, Jahmunah V, Oh SL, Tan RS, Acharya U. Automated diagnostic tool for hypertension using convolutional neural network. Comput Biol Med 2020; 126:103999. [DOI: 10.1016/j.compbiomed.2020.103999] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 08/29/2020] [Accepted: 08/29/2020] [Indexed: 12/13/2022]
|
18
|
Rajput JS, Sharma M, Tan RS, Acharya UR. Automated detection of severity of hypertension ECG signals using an optimal bi-orthogonal wavelet filter bank. Comput Biol Med 2020; 123:103924. [DOI: 10.1016/j.compbiomed.2020.103924] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 07/18/2020] [Accepted: 07/18/2020] [Indexed: 12/18/2022]
|
19
|
|
20
|
Alghamdi A, Hammad M, Ugail H, Abdel-Raheem A, Muhammad K, Khalifa HS, Abd El-Latif AA. Detection of myocardial infarction based on novel deep transfer learning methods for urban healthcare in smart cities. MULTIMEDIA TOOLS AND APPLICATIONS 2020. [DOI: 10.1007/s11042-020-08769-x] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/29/2019] [Accepted: 02/17/2020] [Indexed: 09/02/2023]
|
21
|
Soh DCK, Ng EYK, Jahmunah V, Oh SL, San TR, Acharya UR. A computational intelligence tool for the detection of hypertension using empirical mode decomposition. Comput Biol Med 2020; 118:103630. [PMID: 32174317 DOI: 10.1016/j.compbiomed.2020.103630] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 01/23/2020] [Accepted: 01/24/2020] [Indexed: 12/28/2022]
Abstract
Hypertension (HPT), also known as high blood pressure, is a precursor to heart, brain or kidney diseases. Some symptoms of HPT include headaches, dizziness and fainting. The potential diagnosis of masked hypertension is of specific interest in this study. In masked hypertension (MHPT), the instantaneous blood pressure appears normal, but the 24-h ambulatory blood pressure is abnormal. Hence patients with MHPT are difficult to identify and thus remain untreated or are treated insufficiently. Hence, a computational intelligence tool (CIT) using electrocardiograms (ECG) signals for HPT and possible MHPT detection is proposed in this work. Empirical mode decomposition (EMD) is employed to decompose the pre-processed signals up to five levels. Nonlinear features are extracted from the five intrinsic mode functions (IMFs) thereafter. Student's t-test is subsequently applied to select a set of highly discriminatory features. This feature set is then input to various classifiers, in which, the best accuracy of 97.70% is yielded by the k-nearest neighbor (k-NN) classifier. The developed tool is evaluated by the 10-fold cross validation technique. Our findings suggest that the developed system is useful for diagnostic computational intelligence tool in hospital settings, and that it enables the automatic classification of HPT versus normal ECG signals.
Collapse
Affiliation(s)
| | - E Y K Ng
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore.
| | - V Jahmunah
- School of Engineering, Ngee Ann Polytechnic, Singapore
| | - Shu Lih Oh
- School of Engineering, Ngee Ann Polytechnic, Singapore
| | | | - U Rajendra Acharya
- School of Engineering, Ngee Ann Polytechnic, Singapore; Department of Bioinformatics and Medical Engineering, Asia University, Taiwan; International Research Organization for Advanced Science and Technology (IROAST), Kumamoto University, Kumamoto, Japan
| |
Collapse
|
22
|
A two-stage deep CNN architecture for the classification of low-risk and high-risk hypertension classes using multi-lead ECG signals. INFORMATICS IN MEDICINE UNLOCKED 2020. [DOI: 10.1016/j.imu.2020.100479] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
|