1
|
Uppinakudru AP, Martín-Sómer M, Reynolds K, Stanley S, Bautista LF, Pablos C, Marugán J. Wavelength synergistic effects in continuous flow-through water disinfection systems. WATER RESEARCH X 2023; 21:100208. [PMID: 38098879 PMCID: PMC10719571 DOI: 10.1016/j.wroa.2023.100208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/16/2023] [Accepted: 11/17/2023] [Indexed: 12/17/2023]
Abstract
The past decade's development of UV LEDs has fueled significant research in water disinfection, with widespread debate surrounding the potential synergies of multiple UV wavelengths. This study analyses the use of three UV sources (265, 275, and 310 nm) on the inactivation of Escherichia coli bacteria in two water matrixes. At maximum intensity in wastewater, individual inactivation experiments in a single pass set-up (Flow rate = 2 L min-1, Residence time = 0.75 s) confirmed the 265 nm light source to be the most effective (2.2 ± 0.2 log units), while the 310 nm led to the lowest inactivation rate (0.0003 ± 7.03× 10-5 log units). When a combination of the three wavelengths was used, an average log reduction of 4.4 ± 0.2 was observed in wastewater. For combinations of 265 and 275 nm, the average log reductions were similar to the sum of individual log reductions. For combinations involving the use of 310 nm, a potential synergistic effect was investigated by the use of robust statistical analysis techniques. It is concluded that combinations of 310 nm with 265 nm or 275 nm devices, in sequential and simultaneous mode, present a significant synergy at both intensities due to the emission spectra of the selected LEDs, ensuring the possibility of two inactivation mechanisms. Finally, the electrical energy per order of inactivation found the three-wavelength combination to be the most energy efficient (0.39 ± 0.05, 0.36 ± 0.01 kWh m-3, at 50% and 100% dose, respectively, in wastewater) among the synergistic combinations.
Collapse
Affiliation(s)
- Adithya Pai Uppinakudru
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Miguel Martín-Sómer
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Ken Reynolds
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Simon Stanley
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Luis Fernando Bautista
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Cristina Pablos
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Javier Marugán
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| |
Collapse
|
2
|
Oladipo AO, Oladipo OG, Bezuidenhout CC. Detection of mecA positive staphylococcal species in a wastewater treatment plant in South Africa. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:117165-117178. [PMID: 37864690 PMCID: PMC10682275 DOI: 10.1007/s11356-023-30319-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 10/03/2023] [Indexed: 10/23/2023]
Abstract
We investigated the prevalence of antibiotic resistant staphylococci and detection of resistant, virulence, and Spa genes in a South African wastewater treatment plant. Species identified were Staphylococcus aureus, S. lentus, S. arlettae, S. cohnii, S. haemolyticus, S. nepalensis, S. sciuri (now Mammaliicoccus sciuri), and S. xylosus. Isolates showed high resistance to methicillin (91%), ampicillin (89%), ciprofloxacin (86%), amoxycillin (80%), ceftazidime (74%), and cloxacillin (71%). Multiple antibiotic resistance (MAR) index for the isolates exceeded 0.2 (0.50-0.70). Among the isolates, 77% were mecA-positive. All S. aureus strains were positive for nuc and 7 Spa gene types. The present study highlights possibility of treated wastewaters being potential reservoir for antibiotic-resistant staphylococci. This is a cause for concern as wastewater effluents are decanted into environmental waters and these are, in many cases, used for various purposes including recreation (full contact), religious (full body submersion), and drinking water for some rural communities and water for livestock.
Collapse
Affiliation(s)
- Adegboyega Oyedele Oladipo
- Unit for Environmental Sciences and Management, Microbiology Group, North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom, 2520, South Africa.
- Department of Medical Microbiology and Parasitology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Nigeria.
| | - Oluwatosin Gbemisola Oladipo
- Unit for Environmental Sciences and Management, Microbiology Group, North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom, 2520, South Africa
- Department of Microbiology and Biotechnology, Faculty of Natural and Applied Sciences, First Technical University, Ibadan, Nigeria
| | - Carlos Cornelius Bezuidenhout
- Unit for Environmental Sciences and Management, Microbiology Group, North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom, 2520, South Africa
| |
Collapse
|
3
|
Barjasteh-Askari F, Nabizadeh R, Najafpoor A, Davoudi M, Mahvi AH. Multi-criteria decision-making for prioritizing photocatalytic processes followed by TiO 2-MIL-53(Fe) characterization and application for diazinon removal. Sci Rep 2023; 13:7086. [PMID: 37127696 PMCID: PMC10150684 DOI: 10.1038/s41598-023-34306-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 04/27/2023] [Indexed: 05/03/2023] Open
Abstract
Multi-criteria decision-making (MCDM) can introduce the best option based on evidence. We integrated the Analytic Hierarchy Process (AHP) and the Technique for Order of Preference by Similarity to the Ideal Solution (TOPSIS) to prioritize the alternatives for photocatalytic diazinon removal in a bench scale and characterized TiO2-MIL-53(Fe) for this purpose. Criteria and alternatives were listed based on systematic literature reviews and expert opinions. Then, AHP and TOPSIS questionnaires were developed and distributed to an expert panel for pairwise comparisons. We converted the linguistic variables into the corresponding fuzzy values and used R for mathematical calculations. Then, TiO2-MIL-53(Fe) was synthesized and characterized for diazinon removal under LED visible light. The AHP ranked criteria as availability > degradation efficiency > safety for the environment > material cost > energy consumption > mineralization efficiency > photocatalyst reusability > safety for personnel > equipment cost. Based on TOPSIS, the order of alternatives was TiO2-containing/Visible light > ZnO-containing/UV light > TiO2-containing/UV light > ZnO-containing/Visible light > WO3-containing/UV light. With a bandgap of 1.8 eV, TiO2-MIL-53(Fe) could remove 89.35% of diazinon at 10 mg/L diazinon concentration, 750 mg/L catalyst dose, pH 6.8, and 180-min reaction time. Hybrid AHP-TOPSIS identified the best option for photocatalytic diazinon removal from aqueous solutions. Thus, MCDM techniques can use systematic review results to overcome the uncertainty in designing experimental studies.
Collapse
Affiliation(s)
- Fateme Barjasteh-Askari
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, PourSina St., Qods St., Enghelab St., Tehran, Iran
- Department of Environmental Health Engineering, School of Health, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran
- Health Sciences Research Center, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran
| | - Ramin Nabizadeh
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, PourSina St., Qods St., Enghelab St., Tehran, Iran
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Aliasghar Najafpoor
- Social Determinants of Health Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Environmental Health Engineering, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mojtaba Davoudi
- Social Determinants of Health Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Environmental Health Engineering, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Amir-Hossein Mahvi
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, PourSina St., Qods St., Enghelab St., Tehran, Iran.
- Center for Solid Waste Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
4
|
Reid E, Igou T, Zhao Y, Crittenden J, Huang CH, Westerhoff P, Rittmann B, Drewes JE, Chen Y. The Minus Approach Can Redefine the Standard of Practice of Drinking Water Treatment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:7150-7161. [PMID: 37074125 PMCID: PMC10173460 DOI: 10.1021/acs.est.2c09389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Chlorine-based disinfection for drinking water treatment (DWT) was one of the 20th century's great public health achievements, as it substantially reduced the risk of acute microbial waterborne disease. However, today's chlorinated drinking water is not unambiguously safe; trace levels of regulated and unregulated disinfection byproducts (DBPs), and other known, unknown, and emerging contaminants (KUECs), present chronic risks that make them essential removal targets. Because conventional chemical-based DWT processes do little to remove DBPs or KUECs, alternative approaches are needed to minimize risks by removing DBP precursors and KUECs that are ubiquitous in water supplies. We present the "Minus Approach" as a toolbox of practices and technologies to mitigate KUECs and DBPs without compromising microbiological safety. The Minus Approach reduces problem-causing chemical addition treatment (i.e., the conventional "Plus Approach") by producing biologically stable water containing pathogens at levels having negligible human health risk and substantially lower concentrations of KUECs and DBPs. Aside from ozonation, the Minus Approach avoids primary chemical-based coagulants, disinfectants, and advanced oxidation processes. The Minus Approach focuses on bank filtration, biofiltration, adsorption, and membranes to biologically and physically remove DBP precursors, KUECs, and pathogens; consequently, water purveyors can use ultraviolet light at key locations in conjunction with smaller dosages of secondary chemical disinfectants to minimize microbial regrowth in distribution systems. We describe how the Minus Approach contrasts with the conventional Plus Approach, integrates with artificial intelligence, and can ultimately improve the sustainability performance of water treatment. Finally, we consider barriers to adoption of the Minus Approach.
Collapse
Affiliation(s)
- Elliot Reid
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Thomas Igou
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Yangying Zhao
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - John Crittenden
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
- Brook Byers Institute for Sustainable Systems, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Ching-Hua Huang
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Paul Westerhoff
- Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, School of Sustainable Engineering and The Built Environment, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Bruce Rittmann
- Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, School of Sustainable Engineering and The Built Environment, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona 85287, United States
- Biodesign Swette Center for Environmental Biotechnology, Arizona State University, Tempe, Arizona 85287, United States
| | - Jörg E Drewes
- Chair of Urban Water Systems Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Yongsheng Chen
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
5
|
Sério J, Marques AP, Huertas R, Crespo JG, Pereira VJ. Occurrence and Treatment of Antibiotic-Resistant Bacteria Present in Surface Water. MEMBRANES 2023; 13:425. [PMID: 37103852 PMCID: PMC10141635 DOI: 10.3390/membranes13040425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
According to the World Health Organization, antibiotic resistance is one of the main threats to global health. The excessive use of several antibiotics has led to the widespread distribution of antibiotic-resistant bacteria and antibiotic resistance genes in various environment matrices, including surface water. In this study, total coliforms, Escherichia coli and enterococci, as well as total coliforms and Escherichia coli resistant to ciprofloxacin, levofloxacin, ampicillin, streptomycin, and imipenem, were monitored in several surface water sampling events. A hybrid reactor was used to test the efficiency of membrane filtration, direct photolysis (using UV-C light emitting diodes that emit light at 265 nm and UV-C low pressure mercury lamps that emit light at 254 nm), and the combination of both processes to ensure the retention and inactivation of total coliforms and Escherichia coli as well as antibiotic-resistant bacteria (total coliforms and Escherichia coli) present in river water at occurrence levels. The membranes used (unmodified silicon carbide membranes and the same membrane modified with a photocatalytic layer) effectively retained the target bacteria. Direct photolysis using low-pressure mercury lamps and light-emitting diode panels (emitting at 265 nm) achieved extremely high levels of inactivation of the target bacteria. The combined treatment (unmodified and modified photocatalytic surfaces in combination with UV-C and UV-A light sources) successfully retained the bacteria and treated the feed after 1 h of treatment. The hybrid treatment proposed is a promising approach to use as point-of-use treatment by isolated populations or when conventional systems and electricity fail due to natural disasters or war. Furthermore, the effective treatment obtained when the combined system was used with UV-A light sources indicates that the process may be a promising approach to guarantee water disinfection using natural sunlight.
Collapse
Affiliation(s)
- João Sério
- iBET—Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2780-901 Oeiras, Portugal
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade Nova de Lisboa, Av. da República, 2780-157 Oeiras, Portugal
| | - Ana Paula Marques
- iBET—Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2780-901 Oeiras, Portugal
| | - Rosa Huertas
- iBET—Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2780-901 Oeiras, Portugal
- LAQV-REQUIMTE, Department of Chemistry, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - João Goulão Crespo
- LAQV-REQUIMTE, Department of Chemistry, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Vanessa Jorge Pereira
- iBET—Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2780-901 Oeiras, Portugal
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade Nova de Lisboa, Av. da República, 2780-157 Oeiras, Portugal
| |
Collapse
|
6
|
Gandhi J, Prakash H. Photo-disinfection Processes for Bacterial Inactivation and Underlying Principles for Water Constituents’ Impact: A Review. CHEMICAL ENGINEERING JOURNAL ADVANCES 2023. [DOI: 10.1016/j.ceja.2023.100482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023] Open
|
7
|
Korajkic A, McMinn BR, Harwood VJ. The Effect of Protozoa Indigenous to Lakewater and Wastewater on Decay of Fecal Indicator Bacteria and Coliphage. Pathogens 2023; 12:pathogens12030378. [PMID: 36986300 PMCID: PMC10053992 DOI: 10.3390/pathogens12030378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/20/2023] [Accepted: 02/23/2023] [Indexed: 03/03/2023] Open
Abstract
Fecal indicator bacteria (FIB: Escherichia coli and enterococci) are used to assess recreational water quality. Viral indicators (i.e., somatic and F+ coliphage), could improve the prediction of viral pathogens in recreational waters, however, the impact of environmental factors, including the effect of predatory protozoa source, on their survival in water is poorly understood. We investigated the effect of lakewater or wastewater protozoa, on the decay (decreasing concentrations over time) of culturable FIB and coliphages under sunlight and shaded conditions. FIB decay was generally greater than the coliphages and was more rapid when indicators were exposed to lake vs. wastewater protozoa. F+ coliphage decay was the least affected by experimental variables. Somatic coliphage decayed fastest in the presence of wastewater protozoa and sunlight, though their decay under shaded conditions was-10-fold less than F+ after 14 days. The protozoa source consistently contributed significantly to the decay of FIB, and somatic, though not the F+ coliphage. Sunlight generally accelerated decay, and shade reduced somatic coliphage decay to the lowest level among all the indicators. Differential responses of FIB, somatic, and F+ coliphages to environmental factors support the need for studies that address the relationship between the decay of coliphages and viral pathogens under environmentally relevant conditions.
Collapse
Affiliation(s)
- Asja Korajkic
- United States Environmental Protection Agency, 26W Martin Luther King Jr. Drive, Cincinnati, OH 45268, USA
- Correspondence: ; Tel.: +1-513-569-7306
| | - Brian R. McMinn
- United States Environmental Protection Agency, 26W Martin Luther King Jr. Drive, Cincinnati, OH 45268, USA
| | - Valerie J. Harwood
- Department of Integrative Biology, University of South Florida, 4202 E Fowler Avenue, Tampa, FL 33620, USA
| |
Collapse
|
8
|
Collivignarelli MC, Todeschini S, Abbà A, Ricciardi P, Carnevale Miino M, Torretta V, Rada EC, Conti F, Cillari G, Calatroni S, Lumia G, Bertanza G. The performance evaluation of wastewater service: a protocol based on performance indicators applied to sewer systems and wastewater treatment plants. ENVIRONMENTAL TECHNOLOGY 2022; 43:3426-3443. [PMID: 33900149 DOI: 10.1080/09593330.2021.1922509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 04/20/2021] [Indexed: 06/12/2023]
Abstract
This research aimed to identify a tool to objectively analyse the performance and the environmental contextualisation of sewer systems (SwSs) and wastewater treatment plants (WWTPs). This procedure performs assessment by calculating performance indices which could be subsequently applied to SwSs and WWTPs with different characteristics. The proposed tool can be applied conveniently over the years by managers of integrated urban water management systems for the analysis of different realities also allowing the evaluation of the effects of upgrades carried out during the management phases. The proposed analysis allows the optimisation of SwSs and can profitably guide the choice and the priority among possible interventions for the sewerage infrastructure and WWTPs providing a verification and evaluation protocol as well as a financial planning tool.
Collapse
Affiliation(s)
- Maria Cristina Collivignarelli
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
- Interdepartmental Centre for Water Research, University of Pavia, Pavia, Italy
| | - Sara Todeschini
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
- Interdepartmental Centre for Water Research, University of Pavia, Pavia, Italy
| | - Alessandro Abbà
- Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Brescia, Italy
| | - Paola Ricciardi
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | | | - Vincenzo Torretta
- Department of Theoretical and Applied Sciences, Insubria University, Varese, Italy
| | - Elena Cristina Rada
- Department of Theoretical and Applied Sciences, Insubria University, Varese, Italy
| | - Fabio Conti
- Department of Theoretical and Applied Sciences, Insubria University, Varese, Italy
| | - Giacomo Cillari
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Silvia Calatroni
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Giuseppe Lumia
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Giorgio Bertanza
- Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Brescia, Italy
| |
Collapse
|
9
|
Zahmatkesh S, Amesho KTT, Sillanpää M. A critical review on diverse technologies for advanced wastewater treatment during SARS-CoV-2 pandemic: What do we know? JOURNAL OF HAZARDOUS MATERIALS ADVANCES 2022; 7:100121. [PMID: 37520795 PMCID: PMC9250822 DOI: 10.1016/j.hazadv.2022.100121] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/25/2022] [Accepted: 06/29/2022] [Indexed: 12/23/2022]
Abstract
Advanced wastewater treatment technologies are effective methods and currently attract growing attention, especially in arid and semi-arid areas, for reusing water, reducing water pollution, and explicitly declining, inactivating, or removing SARS-CoV-2. Overall, removing organic matter and micropollutants prior to wastewater reuse is critical, considering that water reclamation can help provide a crop irrigation system and domestic purified water. Advanced wastewater treatment processes are highly recommended for contaminants such as monovalent ions from an abiotic source and SARS-CoV-2 from an abiotic source. This work introduces the fundamental knowledge of various methods in advanced water treatment, including membranes, filtration, Ultraviolet (UV) irradiation, ozonation, chlorination, advanced oxidation processes, activated carbon (AC), and algae. Following that, an analysis of each process for organic matter removal and mitigation or prevention of SARS-CoV-2 contamination is discussed. Next, a comprehensive overview of recent advances and breakthroughs is provided for each technology. Finally, the advantages and disadvantages of each method are discussed.
Collapse
Key Words
- AOP, advanced oxidation process
- Activated carbon
- Advanced oxidation process
- Algae
- BOD, biological oxygen demand
- COD, chemical oxygen demand
- Chlorination
- DBP, disinfection by-product
- EPS, extracellular polymeric substances
- GAC, granular activated carbon
- Membrane
- Micropollutants
- Ozonation
- PAC, powdered activated carbon
- SARS-CoV-2
- TOC, total organic carbon
- TSS, total suspended solids
- UV irradiation
- UV, ultraviolet
- WWTPs, wastewater treatment plants
- Wastewater
Collapse
Affiliation(s)
- Sasan Zahmatkesh
- Department of Chemical Engineering, University of Science and Technology of Mazandaran, P.O. Box 48518-78195, Behshahr, Iran
| | - Kassian T T Amesho
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung 804, Taiwan
- The International University of Management, Centre for Environmental Studies, Main Campus, Dorado Park Ext 1, Windhoek, Namibia
| | - Mika Sillanpää
- Faculty of Science and Technology, School of Applied Physics, University Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
- International Research Centre of Nanotechnology for Himalayan Sustainability (IRCNHS), Shoolini University, Solan, 173212, Himachal Pradesh, India
- Department of Chemical Engineering, School of Mining, Metallurgy and Chemical Engineering, University of Johannesburg, P. O. Box 17011, Doornfontein 2028, South Africa
| |
Collapse
|
10
|
Bîrgovan AL, Lakatos ES, Szilagyi A, Cioca LI, Pacurariu RL, Ciobanu G, Rada EC. How Should We Measure? A Review of Circular Cities Indicators. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:5177. [PMID: 35564570 PMCID: PMC9101551 DOI: 10.3390/ijerph19095177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 04/20/2022] [Indexed: 01/12/2023]
Abstract
As the world continues to urbanize, it is necessary to identify and implement new urban development models and strategies in order to meet the challenges of sustainable development. As cities continue to face challenges in becoming fully circular, the need to establish a framework to measure the circular economy in urban areas grows. Many definitions for circular cities have been developed and addressed in recent years, as have numerous indicators. To make the transition to a circular city, we must integrate the findings and develop a general definition and measurement framework. This article aims at outlining a framework for circular cities indicators based on their key characteristics, as well providing directions for fostering circularity at the city level. To accomplish this goal, we conducted a systematic review and analyzed key papers published in the field of circular economy to determine how circular cities are measured. Choosing the right indicators to use for developing, monitoring, and evaluating circular cities is a difficult task for urban policymakers, managers, and planners. This highlights the significance of standardized frameworks for urban indicators. As a result, the authors propose a framework and highlight some key points about circular cities and smart urban metabolism.
Collapse
Affiliation(s)
- Andreea Loredana Bîrgovan
- Institute for Research in Circular Economy and Environment “Ernest Lupan”, Calea Dorobantilor 71-73, 400609 Cluj-Napoca, Romania; (A.L.B.); (E.S.L.); (A.S.); (R.L.P.)
- Faculty of Industrial Engineering, Robotics and Production Management, Engineering and Management, Technical University of Cluj-Napoca, B-ul Muncii 103-105, 400609 Cluj-Napoca, Romania
| | - Elena Simina Lakatos
- Institute for Research in Circular Economy and Environment “Ernest Lupan”, Calea Dorobantilor 71-73, 400609 Cluj-Napoca, Romania; (A.L.B.); (E.S.L.); (A.S.); (R.L.P.)
- Faculty of Industrial Engineering, Robotics and Production Management, Engineering and Management, Technical University of Cluj-Napoca, B-ul Muncii 103-105, 400609 Cluj-Napoca, Romania
| | - Andrea Szilagyi
- Institute for Research in Circular Economy and Environment “Ernest Lupan”, Calea Dorobantilor 71-73, 400609 Cluj-Napoca, Romania; (A.L.B.); (E.S.L.); (A.S.); (R.L.P.)
- Faculty of Industrial Engineering, Robotics and Production Management, Engineering and Management, Technical University of Cluj-Napoca, B-ul Muncii 103-105, 400609 Cluj-Napoca, Romania
| | - Lucian Ionel Cioca
- Faculty of Engineering, Lucian Blaga University of Sibiu, Blv. Victoriei 10, 550024 Sibiu, Romania;
- Academy of Romanian Scientists, 010071 Bucharest, Romania
| | - Roxana Lavinia Pacurariu
- Institute for Research in Circular Economy and Environment “Ernest Lupan”, Calea Dorobantilor 71-73, 400609 Cluj-Napoca, Romania; (A.L.B.); (E.S.L.); (A.S.); (R.L.P.)
| | - George Ciobanu
- Faculty of Economics and Business Administration, University of Craiova, Str. Alexandru Ioan Cusa 13, 200585 Craiova, Romania;
| | - Elena Cristina Rada
- Department of Theoretical and Applied Sciences, Insubria University of Varese, Via G.B. Vico 46, 21100 Varese, Italy
| |
Collapse
|
11
|
Tshangana CS, Muleja AA, Kuvarega AT, Mamba BB. The synergistic effect of peracetic acid activated by graphene oxide quantum dots in the inactivation of E. coli and organic dye removal with LED reactor light. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2022; 57:268-281. [PMID: 35354352 DOI: 10.1080/10934529.2022.2056385] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 03/08/2022] [Accepted: 03/08/2022] [Indexed: 06/14/2023]
Abstract
This study presents a low-impact process that uses the synergy of peracetic acid (PAA) and graphene oxide quantum GQDs to degrade poorly biodegradable organic compounds and potentially substitute chlorination in wastewater treatment. The role of GQDs in GQDs/PAA activity and the effect of GQDs loading were examined. The results showed that increasing GQDs loading in the GQDs/PAA system greatly improved the photodegradation efficiency. Conversely, increasing the PAA concentration slightly enhanced efficiency due to few active sites being available. GQDs acted as catalysts and radical scavenging experiments confirmed that the degradation occurred via generation of hydroxyl (•OH) and peroxy (CH3C(=O)OO•)) radicals. A probable degradation mechanism of the organic dye was presented based on the reaction by-products detected after HPLC-MS studies. The E. coli inactivation mechanism was elucidated by monitoring the morphological changes of E. coli using scanning microscopy. The proposed antimicrobial mechanism includes the initial diffusion of PAA through the cell membrane which caused damage and induced cellular matter leakage, resulting in cell death. Bacterial regrowth studies confirmed GQDs/PAA were able to bypass the natural mechanisms of microorganisms that enables them to repair any damages in their DNA.
Collapse
Affiliation(s)
- Charmaine Sesethu Tshangana
- Institute for Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Florida Park, Roodepoort, South Africa
| | - Adolph Anga Muleja
- Institute for Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Florida Park, Roodepoort, South Africa
| | - Alex Tawanda Kuvarega
- Institute for Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Florida Park, Roodepoort, South Africa
| | - Bhekie Brilliance Mamba
- Institute for Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Florida Park, Roodepoort, South Africa
| |
Collapse
|
12
|
Aspergillus niger Culture Filtrate (ACF) Mediated Biocontrol of Enteric Pathogens in Wastewater. WATER 2022. [DOI: 10.3390/w14010119] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Robust control of pathogens in sewage facilitates safe reuse of wastewater rich in valuable nutrients for potential valorization through biological means. Aspergillus niger is widely reported in bioremediation of wastewater but studies on control of enteric pathogens in sewage are very sparse. So, this study aimed at exploring the antibacterial and nematicidal activity of A. niger culture filtrate (ACF). Antibacterial activity of ACF on enteric pathogens (Klebsiella pneumoniae, Pseudomonas aeruginosa, Vibrio cholerae, Salmonella enterica, Shigella dysenteriae, Escherichia coli, Staphylococcus aureus, Klebsiella variicola) was determined by spectrophotometric growth analysis, resazurin based viability assay and biofilm formation assay. ACF showed inhibition against all enteric pathogens except Pseudomonas aeruginosa. Nematicidal studies on Caenorhabditis elegans showed 85% egg hatch inhibition and 52% mortality of L1 larvae. Sewage treatment with ACF at 1:1 (v/v) showed 2–3 log reduction in coliforms, Klebsiella, Shigella, Salmonella, S. aureus and Vibrio except Pseudomonas, indicating significant alteration of complex microbial dynamics in wastewater. Application of ACF can potentially be used as a robust biocontrol strategy against infectious microbes in wastewater and subsequent valorization by cultivating beneficial Pseudomonas.
Collapse
|
13
|
Collivignarelli MC, Abbà A, Carnevale Miino M, Bertanza G, Sorlini S, Damiani S, Arab H, Bestetti M, Franz S. Photoelectrocatalysis on TiO 2 meshes: different applications in the integrated urban water management. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:59452-59461. [PMID: 33570731 PMCID: PMC8541951 DOI: 10.1007/s11356-021-12606-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 01/18/2021] [Indexed: 06/12/2023]
Abstract
Recently, among AOPs, photoelectrocatalysis (PEC) on TiO2 is gaining interest. In this study, five different real waters sampled in four different points of the integrated urban water management (IUWM) system were tested with PEC and UV alone, for comparison. This work aims to verify the effect of the PEC suggesting the optimal position in IUWM system where the PEC should be located to obtain the best performance. In groundwaters (GWs), PEC effectively removed atrazine-based compounds (> 99%), trichloroethylene, and perchloroethylene (96%), after 15 min of reaction time. However, given the low concentrations of emerging compounds, the synergistic effect of UV radiation with the catalyst and with the polarization of the mesh was not visible, with very few differences compared with the results obtained with UV alone. Pharmaceutical industrial wastewater (IWW) showed a significant increase in biodegradability after 2 h, both if subjected to PEC or UV (200%), despite the absence of COD removal. The PEC applied on IWW from a sewage sludge treatment plant allowed to effectively remove the COD (39.6%) and increase the biodegradability (300%). Good results in terms of COD removal (33.9%) and biodegradability increase (+900%) were also achieved testing PEC on wastewater treatment plant effluent. Except for GWs, PEC allowed significant EEO savings respect to UV alone (76.2-99.1%).
Collapse
Affiliation(s)
- Maria Cristina Collivignarelli
- Department of Civil Engineering and Architecture, University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
- Interdepartmental Centre for Water Research, University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Alessandro Abbà
- Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Via Branze 43, 25123 Brescia, Italy
| | - Marco Carnevale Miino
- Department of Civil Engineering and Architecture, University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Giorgio Bertanza
- Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Via Branze 43, 25123 Brescia, Italy
| | - Sabrina Sorlini
- Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Via Branze 43, 25123 Brescia, Italy
| | - Silvestro Damiani
- Department of Civil Engineering and Architecture, University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Hamed Arab
- Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Via Mancinelli 7, 20131 Milano, Italy
| | - Massimiliano Bestetti
- Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Via Mancinelli 7, 20131 Milano, Italy
| | - Silvia Franz
- Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Via Mancinelli 7, 20131 Milano, Italy
| |
Collapse
|
14
|
Shahzad A, Oh JM, Azam M, Iqbal J, Hussain S, Miran W, Rasool K. Advances in the Synthesis and Application of Anti-Fouling Membranes Using Two-Dimensional Nanomaterials. MEMBRANES 2021; 11:605. [PMID: 34436368 PMCID: PMC8402026 DOI: 10.3390/membranes11080605] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 07/29/2021] [Accepted: 07/30/2021] [Indexed: 11/16/2022]
Abstract
This article provides a comprehensive review of the recent progress in the application of advanced two-dimensional nanomaterials (2DNMs) in membranes fabrication and application for water purification. The membranes fouling, its types, and anti-fouling mechanisms of different 2DNMs containing membrane systems are also discussed. The developments in membrane synthesis and modification using 2DNMs, especially graphene and graphene family materials, carbon nanotubes (CNTs), MXenes, and others are critically reviewed. Further, the application potential of next-generation 2DNMs-based membranes in water/wastewater treatment systems is surveyed. Finally, the current problems and future opportunities of applying 2DNMs for anti-fouling membranes are also debated.
Collapse
Affiliation(s)
- Asif Shahzad
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul 04620, Korea; (A.S.); (J.-M.O.)
| | - Jae-Min Oh
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul 04620, Korea; (A.S.); (J.-M.O.)
| | - Mudassar Azam
- Institute of Chemical Engineering & Technology, University of Punjab, Lahore 54590, Pakistan;
| | - Jibran Iqbal
- College of Natural and Health Sciences, Zayed University, Abu Dhabi 144534, United Arab Emirates;
| | - Sabir Hussain
- Department of Environmental Sciences and Engineering, Government College University, Faisalabad 38000, Pakistan;
| | - Waheed Miran
- International Center for Materials Nanoarchitectonics, National Institute for Materials Science, Tsukuba 305-0044, Japan
| | - Kashif Rasool
- Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University (HBKU), Qatar Foundation, Doha 5824, Qatar
| |
Collapse
|
15
|
The Pathway towards Photoelectrocatalytic Water Disinfection: Review and Prospects of a Powerful Sustainable Tool. Catalysts 2021. [DOI: 10.3390/catal11080921] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Photoelectrocatalysis is a hybrid photon/electron-driven process that benefits from the synergistic effects of both processes to enhance and stabilize the generation of disinfecting oxidants. Photoelectrocatalysis is an easy to operate technology that can be scaled-up or scaled-down for various water treatment applications as low-cost decentralized systems. This review article describes the fundamentals of photoelectrocatalysis, applied to water disinfection to ensure access to clean water for all as a sustainable development goal. Advances in reactor engineering design that integrate light-delivery and electrochemical system requirements are presented, with a description of photo-electrode material advances, including doping, nano-decoration, and nanostructure control. Disinfection and cell inactivation are described using different model microorganisms such as E. coli, Mycobacteria, Legionella, etc., as well the fungus Candida parapsilosis, with relevant figures of merit. The key advances in the elucidation of bacterial inactivation mechanisms by photoelectrocatalytic treatments are presented and knowledge gaps identified. Finally, prospects and further research needs are outlined, to define the pathway towards the future of photoelectrocatalytic disinfection technologies.
Collapse
|
16
|
Simultaneous Disinfection and Organic Microcontaminant Removal by UVC-LED-Driven Advanced Oxidation Processes. WATER 2021. [DOI: 10.3390/w13111507] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This work presents the comparison of four advanced oxidation processes driven by UVC-LED radiation (278 nm—2 W/m2) for simultaneous bacteria inactivation (Escherichia coli—106 CFU/mL) and microcontaminant removal (imidacloprid—50 µg/L) in simulated wastewater secondary effluent. To this end, the activation of H2O2 and S2O82− as precursors of HO• and SO4•−, respectively, by UVC-LED and UVC-LED/Fe3+–NTA (ferric nitrilotriacetate at 0.1 mM) has been studied at different oxidant concentrations. For the purpose of comparison, conventional chlorination was used as the baseline along with bacterial regrowth 24 h after treatment. Disinfection was achieved within the first 30 min in all of the processes, mainly due to the bactericidal effect of UVC-LED radiation. UVC-LED/H2O2 did not substantially affect imidacloprid removal due to the low HO• generation by UVC irradiation at 278 nm, while more than 80% imidacloprid removal was achieved by the UVC-LED/S2O82−, UVC-LED/Fe3+–NTA/S2O82−, and UVC-LED/Fe3+–NTA/H2O2 processes. The most efficient concentration of both oxidants for the simultaneous disinfection and microcontaminant removal was 1.47 mM. Chlorination was the most effective treatment for bacterial inactivation without imidacloprid removal. These findings are relevant for scaling up UVC-LED photoreactors for tertiary wastewater treatment aimed at removing bacteria and microcontaminants.
Collapse
|
17
|
Voigt M, Bartels I, Schmiemann D, Votel L, Hoffmann-Jacobsen K, Jaeger M. Metoprolol and Its Degradation and Transformation Products Using AOPs-Assessment of Aquatic Ecotoxicity Using QSAR. Molecules 2021; 26:3102. [PMID: 34067394 PMCID: PMC8196942 DOI: 10.3390/molecules26113102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/17/2021] [Accepted: 05/19/2021] [Indexed: 11/17/2022] Open
Abstract
Pharmaceuticals are found in waterbodies worldwide. Conventional sewage treatment plants are often not able to eliminate these micropollutants. Hence, Advanced Oxidation Processes (AOPs) have been heavily investigated. Here, metoprolol is exposed to UV irradiation, hydrogen peroxide, and ozonation. Degradation was analyzed using chemical kinetics both for initial and secondary products. Photo-induced irradiation enhanced by hydrogen peroxide addition accelerated degradation more than ozonation, leading to complete elimination. Degradation and transformation products were identified by high-performance liquid-chromatography coupled to high-resolution higher-order mass spectrometry. The proposed structures allowed to apply Quantitative Structure-Activity Relationship (QSAR) analysis to predict ecotoxicity. Degradation products were generally associated with a lower ecotoxicological hazard to the aquatic environment according to OECD QSAR toolbox and VEGA. Comparison of potential structural isomers suggested forecasts may become more reliable with larger databases in the future.
Collapse
Affiliation(s)
- Melanie Voigt
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
| | - Indra Bartels
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
- Faculty of Chemistry, University Duisburg-Essen, Universitätsstraße 2, D-45141 Essen, Germany
| | - Dorothee Schmiemann
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
- Faculty of Chemistry, University Duisburg-Essen, Universitätsstraße 2, D-45141 Essen, Germany
| | - Lars Votel
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
| | - Kerstin Hoffmann-Jacobsen
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
| | - Martin Jaeger
- Department of Chemistry and ILOC, Niederrhein University of Applied Sciences, Adlerstraße 32, D-47798 Krefeld, Germany; (M.V.); (I.B.); (D.S.); (L.V.); (K.H.-J.)
| |
Collapse
|