1
|
Rodríguez Montaño R, Alarcón-Sánchez MA, Martínez Nieto M, Varela Hernández JJ, Lomelí Martínez SM. Application of nanotechnology to dentistry: Impact of graphene nanocomposites on clinical air quality. World J Clin Cases 2025; 13:100839. [DOI: 10.12998/wjcc.v13.i8.100839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Revised: 11/02/2024] [Accepted: 11/15/2024] [Indexed: 12/04/2024] Open
Abstract
Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks, have prompted investigations on advanced disinfection technologies. This editorial describes the strengths and limitations of ventilation and aerosol control measures in dental offices, especially with respect to the use of graphene nanocomposites. The potential of graphene nanocomposites as an innovative solution to aerosol-associated health risks is examined in this review due to the unique properties of graphene (e.g., high conductivity, mechanical strength, and antimicrobial activity). These properties have produced promising results in various fields, but the application of graphene in dentistry remains unexplored. The recent study by Ju et al which was published in World Journal of Clinical Cases evaluated the effectiveness of graphene-based air disinfection systems in dental clinics. The study demonstrated that graphene-based disinfection techniques produced significant reductions in suspended particulate matter and bacterial colony counts, when compared with traditional methods. Despite these positive results, challenges such as material saturation, frequency of filter replacement, and associated costs must be addressed before widespread adoption of graphene-based disinfection techniques in clinical practice. Therefore, there is need for further research on material structure optimization, long-term safety evaluations, and broader clinical applications, in order to maximize their positive impact on public health.
Collapse
Affiliation(s)
- Ruth Rodríguez Montaño
- Department of Health and Illness as an Individual and Collective Process, University Center of Tlajomulco, University of Guadalajara, Tlajomulco de Zuñiga 45641, Jalisco, Mexico
- Institute of Research in Dentistry, Department of Integral Dental Clinics, University Center of Health Sciences, University of Guadalajara, Guadalajara 44340, Jalisco, Mexico
| | - Mario A Alarcón-Sánchez
- Department of Biomedical Science, Faculty of Chemical-Biological Sciences, Autonomous University of Guerrero, Guerrero 39090, Mexico
- Instituto Odontológico del Pacífico Sur, Chilpancingo de los Bravo 39022, Mexico
| | | | - Juan J Varela Hernández
- Department of Medical and Life Sciences, Centro Universitario de la Ciénega, Universidad de Guadalajara, Ocotlan 47810, Jalisco, Mexico
| | - Sarah M Lomelí Martínez
- Department of Medical and Life Sciences, Centro Universitario de la Ciénega, Universidad de Guadalajara, Ocotlan 47810, Jalisco, Mexico
- Master of Public Health, Department of Well-being and Sustainable Development, Centro Universitario del Norte, Universidad de Guadalajara, Ocotlan 46200, Jalisco, Mexico
| |
Collapse
|
2
|
Yao G, Liu Z, Liu H, Jiang C, Li Y, Liu J, He J. Air disinfection performance of upper-room ultraviolet germicidal irradiation (UR-UVGI) system in a multi-compartment dental clinic. JOURNAL OF HAZARDOUS MATERIALS 2024; 477:135383. [PMID: 39094316 DOI: 10.1016/j.jhazmat.2024.135383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 07/27/2024] [Accepted: 07/29/2024] [Indexed: 08/04/2024]
Abstract
Multi-compartment dental clinics present significant airborne cross-infection risks. Upper-room ultraviolet germicidal irradiation (UR-UVGI) system have shown promise in preventing airborne pathogens, but its available application data are insufficient in multi-compartment dental clinics. Therefore, the UR-UVGI system's performance in a multi-compartment dental clinic was comprehensively evaluated in this study. The accuracy of the turbulence and drift flux models was verified by experimental data from ultrasonic scaling. The effects of the ventilation rate, irradiation zone volume, and irradiation flux on UR-UVGI performance were analyzed using computational fluid dynamics coupled with a UV inactivation model. Different patient numbers were considered. The results showed that UR-UVGI significantly reduced virus concentrations and outperformed increased ventilation rates alone. At a ventilation rate of six air changes per hour (ACH), UR-UVGI with an irradiation zone volume of 20% and irradiation flux of 5 μW/cm2 achieved a 70.44% average virus reduction in the whole room (WR), outperforming the impact of doubling the ventilation rate from 6 to 12 ACH without UR-UVGI. The highest disinfection efficiency of UR-UVGI decreased for WRs with more patients. The compartment treating patients exhibited significantly lower disinfection efficiency than others. Moreover, optimal UR-UVGI performance occurs at lower ventilation rates, achieving over 80% virus disinfection in WR. Additionally, exceeding an irradiation zone volume of 20% or an irradiation flux of 5 μW/cm2 notably reduces the improvement rates of UR-UVGI performance. These findings provide a scientific reference for strategically applying UR-UVGI in multi-compartment dental clinics.
Collapse
Affiliation(s)
- Guangpeng Yao
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei 071003, PR China
| | - Zhijian Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei 071003, PR China.
| | - Haiyang Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei 071003, PR China
| | - Chuan Jiang
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei 071003, PR China
| | - Yabin Li
- The Fifth Medical Center of PLA General Hospital, Beijing 100039, PR China
| | - Jia Liu
- The Fifth Medical Center of PLA General Hospital, Beijing 100039, PR China
| | - Junzhou He
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei 071003, PR China.
| |
Collapse
|
3
|
Li Y, Li J, Hu J, Yu X, Li Z, Cao J. Quantitative evaluation of the impact of indoor relative humidity on deposition of aerosols generated during tooth grinding in a real-world clinical setting. Clin Oral Investig 2024; 28:292. [PMID: 38693418 DOI: 10.1007/s00784-024-05683-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024]
Abstract
OBJECTIVES Exposure to aerosol particles generated from tooth grinding has a negative impact on the health of dental personnel. The aim of this study was to quantitatively analyze the impact of indoor relative humidity (IRH) on the deposition of these suspended particles in a well-controlled dental environment. MATERIALS AND METHODS In this study, a humidity control system was employed to effectively regulate and maintain indoor relative humidity (IRH). A novel computer-assisted numerical control system was developed to pre-treat the molar specimens, and accurately simulate clinical tooth grinding procedures. Each procedure was performed in triplicate, with an online real-time particle counter (ORPC; TR-8301, TongrenCo.) measuring aerosol production. All testing devices were controlled remotely. The data obtained were statistically analyzed using descriptive statistics and non-parametric tests (Kruskal-Wallis/ Dunn's post hoc test with Bonferroni correction, p < 0.05). RESULTS The findings showed that with increasing IRH, the maximum peak concentration of aerosol particles decreased by 397% from 6.51 × 107 particles/m3 at 30% to 1.64 × 107 particles/m3 at 80%. The Kruskal-Wallis test results indicated a statistically significant effect of IRH on the aerosol increment (p < 0.05). CONCLUSIONS Increasing the IRH level can effectively promote the deposition of aerosol particles, with a return to baseline within 15 min after reaching 60% or above. CLINICAL RELEVANCE Our study suggested that maintaining IRH above 70% during the cleaning process, allowing natural recovery to ambient humidity levels within 15 min after cleaning, and taking basic precautions, may lead to an adequate reduction in the possible health risks of aerosol contamination.
Collapse
Affiliation(s)
- Yugang Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China
- Guizhou Equipment Manufacturing Polytechnic, Guiyang, China
| | - Jiachun Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China.
| | - Jie Hu
- School of Mechanical Engineering, Guizhou University, Guiyang, China.
| | - Xiaoyan Yu
- Guiyang Hospital of Stomatology, Guiyang, China
| | - Zhe Li
- School of Life Sciences, Guizhou Normal University, Guiyang, China
| | - Jichao Cao
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, China
| |
Collapse
|
4
|
Alqarni Z, Rezgui Y, Petri I, Ghoroghi A. Viral infection transmission and indoor air quality: A systematic review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 923:171308. [PMID: 38432379 DOI: 10.1016/j.scitotenv.2024.171308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/03/2024] [Accepted: 02/25/2024] [Indexed: 03/05/2024]
Abstract
Respiratory disease transmission in indoor environments presents persistent challenges for health authorities, as exemplified by the recent COVID-19 pandemic. This underscores the urgent necessity to investigate the dynamics of viral infection transmission within indoor environments. This systematic review delves into the methodologies of respiratory infection transmission in indoor settings and explores how the quality of indoor air (IAQ) can be controlled to alleviate this risk while considering the imperative of sustainability. Among the 2722 articles reviewed, 178 were retained based on their focus on respiratory viral infection transmission and IAQ. Fifty eight articles delved into SARS-CoV-2 transmission, 21 papers evaluated IAQ in contexts of other pandemics, 53 papers assessed IAQ during the SARS-CoV-2 pandemic, and 46 papers examined control strategies to mitigate infectious transmission. Furthermore, of the 46 papers investigating control strategies, only nine considered energy consumption. These findings highlight clear gaps in current research, such as analyzing indoor air and surface samples for specific indoor environments, oversight of indoor and outdoor parameters (e.g., temperature, relative humidity (RH), and building orientation), neglect of occupancy schedules, and the absence of considerations for energy consumption while enhancing IAQ. This study distinctly identifies the indoor environmental conditions conducive to the thriving of each respiratory virus, offering IAQ trade-offs to mitigate the risk of dominant viruses at any given time. This study argues that future research should involve digital twins in conjunction with machine learning (ML) techniques. This approach aims to enhance IAQ by analyzing the transmission patterns of various respiratory viruses while considering energy consumption.
Collapse
Affiliation(s)
- Zahi Alqarni
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK; School of Computer Science, King Khalid University, Abha 62529, Saudi Arabia.
| | - Yacine Rezgui
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ioan Petri
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ali Ghoroghi
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| |
Collapse
|
5
|
Li Y, Wei L, Lin J, Xie Z, Lu L, Pan X, Xu J, Cai R. Nonthermal plasma air disinfection for the inactivation of airborne microorganisms in an experimental chamber and indoor air. J Appl Microbiol 2024; 135:lxae078. [PMID: 38520159 DOI: 10.1093/jambio/lxae078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 02/28/2024] [Accepted: 03/21/2024] [Indexed: 03/25/2024]
Abstract
AIMS Airborne transmission of diseases presents a serious threat to human health, so effective air disinfection technology to eliminate microorganisms in indoor air is very important. This study evaluated the effectiveness of a non-thermal plasma (NTP) air disinfector in both laboratory experiments and real environments. METHODS AND RESULTS An experimental chamber was artificially polluted with a bioaerosol containing bacteria or viruses. Additionally, classroom environments with and without people present were used in field tests. Airborne microbial and particle concentrations were quantified. A 3.0 log10 reduction in the initial load was achieved when a virus-containing aerosol was disinfected for 60 min and a bacteria-containing aerosol was disinfected for 90 min. In the field test, when no people were present in the room, NTP disinfection decreased the airborne microbial and particle concentrations (P < 0.05). When people were present in the room, their constant activity continuously contaminated the indoor air, but all airborne indicators decreased (P < 0.05) except for planktonic bacteria (P = 0.094). CONCLUSIONS NTP effectively inactivated microorganisms and particles in indoor air.
Collapse
Affiliation(s)
- Ye Li
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Lanfen Wei
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Junming Lin
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Zhongyi Xie
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Longxi Lu
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Xieshang Pan
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Ji Xu
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| | - Ran Cai
- Department of Environmental Health, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China
| |
Collapse
|
6
|
Watanabe J, Iwamatsu-Kobayashi Y, Kikuchi K, Kajita T, Morishima H, Yamauchi K, Yashiro W, Nishimura H, Kanetaka H, Egusa H. Visualization of droplets and aerosols in simulated dental treatments to clarify the effectiveness of oral suction devices. J Prosthodont Res 2024; 68:85-91. [PMID: 36823102 DOI: 10.2186/jpr.jpr_d_23_00013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
PURPOSE The hazards of aerosols generated during dental treatments are poorly understood. This study aimed to establish visualization methods, discover conditions for droplets/aerosols generated in simulating dental treatments and identify the conditions for effective suction methods. METHODS The spreading area was evaluated via image analysis of the droplets/aerosols generated by a dental air turbine on a mannequin using a light emitting diode (LED) light source and high-speed camera. The effects of different bur types and treatment sites, reduction effect of intra-oral suction (IOS) and extra-oral suction (EOS) devices, and effect of EOS installation conditions were evaluated. RESULTS Regarding the bur types, a bud-shaped bur on the air turbine generated the most droplets/aerosols compared with round-shaped, round end-tapered, or needle-tapered burs. Regarding the treatment site, the area of droplets/aerosols produced by an air turbine from the palatal plane of the anterior maxillary teeth was significantly higher. The generated droplet/aerosol area was reduced by 92.1% by using IOS alone and 97.8% by combining IOS and EOS. EOS most effectively aspirated droplets/aerosols when placed close (10 cm) to the mouth in the vertical direction (0°). CONCLUSIONS The droplets/aerosols generated by an air turbine could be visualized using an LED light and a high-speed camera in simulating dental treatments. The bur shape and position of the dental air turbine considerably influenced droplet/aerosol diffusion. The combined use of IOS and EOS at a proper position (close and perpendicular to the mouth) facilitated effective diffusion prevention to protect the dental-care environment.
Collapse
Affiliation(s)
- Jun Watanabe
- Division of Dental Safety and System Management, Tohoku University Hospital, Sendai
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
| | - Yoko Iwamatsu-Kobayashi
- Division of Dental Safety and System Management, Tohoku University Hospital, Sendai
- Liaison Centre for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai
| | - Kenji Kikuchi
- Biological Flow Studies Laboratory, Department of Finemechanics, Graduate School of Engineering, Tohoku University, Sendai
| | - Tomonari Kajita
- Division of Oral and Maxillofacial Oncology and Surgical Sciences, Tohoku University Graduate School of Dentistry, Sendai
| | - Hiromitsu Morishima
- Division of Oral and Maxillofacial Reconstructive Surgery, Tohoku University Graduate School of Dentistry, Sendai
| | - Kensuke Yamauchi
- Division of Oral and Maxillofacial Reconstructive Surgery, Tohoku University Graduate School of Dentistry, Sendai
| | - Wataru Yashiro
- Next-Generation Detection System Smart Lab, International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, Sendai
- Frontier Quantum-beam Metrology Laboratory, Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, Sendai
- Department of Applied Physics, School of Engineering, The University of Tokyo, Tokyo, Japan
| | - Hidekazu Nishimura
- Virus Research Center, Clinical Research Division, Sendai Medical Center, National Hospital Organization, Sendai
| | - Hiroyasu Kanetaka
- Liaison Centre for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai
| | - Hiroshi Egusa
- Division of Dental Safety and System Management, Tohoku University Hospital, Sendai
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
- Liaison Centre for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai
| |
Collapse
|
7
|
Li YG, Li JC, Yu XY, Hu J, Li Z, Cao JC. Quantitative assessment of aerosol contamination generated during tooth grinding with a speed-increasing handpiece. J Dent 2023; 139:104631. [PMID: 37495202 DOI: 10.1016/j.jdent.2023.104631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 06/29/2023] [Accepted: 07/21/2023] [Indexed: 07/28/2023] Open
Abstract
OBJECTIVES Tooth grinding produces a significant amount of aerosol particles. The aim of this study was to quantitatively assess particle contamination produced from tooth grinding with a speed-increasing handpiece across a real-world clinical setting. METHODS All molar crowns were pretreated into cylinders with a uniform size. A novel computer-assisted numerical control system was used to parametrically study the bur speed: from 20,000 (20 K) to 200 K rpm at 20 K rpm intervals. 5-minute tooth grinding was performed in triplicate at each speed setting. Three online real-time particle counters (ORPC; TR-8301, TongrenCo.) were placed at 3 positions (0.5, 1, and 1.5 m) to evaluate particle production. All experimental instruments were controlled remotely. The data obtained were statistically analyzed using descriptive statistics and non-parametric tests (Scheirer-Ray-Hare and Kruskal-Wallis/ Dunn-Bonferroni tests, p < 0.05). RESULTS The concentration level of aerosol particles production during the grinding experiment was elevated above the control group for all conditions, and increased with bur speed at any location (the maximum peak, reaching 5.59 × 107 particles/m3, at 200 K and 1 m), with differences between conditions. The effect of speed on the increment of particles across different channels compared to the control group was statistically significant among locations (p < 0.001). CONCLUSIONS Statistically significant particle contamination was produced using a speed-increasing handpiece, but the contamination level for each experimental condition was reduced to baseline within 30 min, and most particles with a diameter greater than 1üm produced at low speeds (80 K or lower) tended to settle within 1 m. CLINICAL RELEVANCE Our study suggested that the use of a speed-increasing handpiece below 80 K and 30 min of fallow time may lead to an adequate reduction in the health effects of particle contamination.
Collapse
Affiliation(s)
- Yu-Gang Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China; Guizhou Equipment Manufacturing Polytechnic, Guiyang, China
| | - Jia-Chun Li
- School of Mechanical Engineering, Guizhou University, Guiyang, China.
| | - Xiao-Yan Yu
- Guiyang Hospital of Stomatology, Guiyang, China
| | - Jie Hu
- School of Mechanical Engineering, Guizhou University, Guiyang, China
| | - Zhe Li
- School of Life Sciences, Guizhou Normal University, Guiyang, China
| | - Ji-Chao Cao
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, China
| |
Collapse
|
8
|
Yang X, Liu R, Zhu J, Luo T, Zhan Y, Li C, Li Y, Yu H. Evaluating the microbial aerosol generated by dental instruments: addressing new challenges for oral healthcare in the hospital infection. BMC Oral Health 2023; 23:409. [PMID: 37344797 DOI: 10.1186/s12903-023-03109-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 06/06/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Using a rotary instrument or ultrasonic instrument for tooth preparation is a basic operation in the dental clinic that can produce a significant number of droplets and aerosols. The dental droplet and aerosol can lead to the transfer of harmful germs. The goal of this study was to analyze the properties of microbiological aerosol created by droplets and aerosol generated by three common tooth-preparation instruments. METHODS Streptococcus mutans UA159 was used as the biological tracer to visualize the droplets and aerosols. The passive sampling method was used to map the three-dimensional spatial distribution and the six-stage Andersen microbial sampler (AMS) was used as the active sampling method to catch aerosol particles at a specific time. RESULTS The aerosol concentration is related to instruments, three-dimensional spatial distribution, and dissipation time. Most aerosols were generated by air turbines. More microorganisms are concentrated at the 1.5 m plane. The majority of the post dental procedure contamination was detected within the 0-10-min period and it decreased rapidly within 30 min. CONCLUSION This study is conducive to the proposal and improvement of relevant infection control measures in dental procedures and provides a basis for the assessment of measures, reducing the risk of nosocomial infection.
Collapse
Affiliation(s)
- Xin Yang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
- Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3Rd Section of Ren Min Nan Rd, Chengdu, 610041, Sichuan Province, China
| | - Ruolan Liu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
- Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3Rd Section of Ren Min Nan Rd, Chengdu, 610041, Sichuan Province, China
| | - Jiakang Zhu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
- Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3Rd Section of Ren Min Nan Rd, Chengdu, 610041, Sichuan Province, China
| | - Tian Luo
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
- Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3Rd Section of Ren Min Nan Rd, Chengdu, 610041, Sichuan Province, China
| | - Yu Zhan
- Department of Environmental Science and Engineering, Sichuan University, Chengdu, 610065, Sichuan, China
| | - Chunyuan Li
- Department of Environmental Science and Engineering, Sichuan University, Chengdu, 610065, Sichuan, China
| | - Yuqing Li
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China.
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China.
- Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, 3Rd Section of Ren Min Nan Rd, Chengdu, 610041, Sichuan Province, China.
| |
Collapse
|
9
|
Ding J, Li J, Qi J, Fu L. Characterization of dental dust particles and their pathogenicity to respiratory system: a narrative review. Clin Oral Investig 2023; 27:1815-1829. [PMID: 36773127 PMCID: PMC9918839 DOI: 10.1007/s00784-023-04910-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Accepted: 02/03/2023] [Indexed: 02/12/2023]
Abstract
OBJECTIVES Dental professionals are exposed to large amounts of dust particles during routine treatment and denture processing. This article provides a narrative review to investigate the most prevalent dust-related respiratory diseases among dental professionals and to discuss the effects of dental dust on human respiratory health. MATERIALS AND METHODS A literature search was performed in PubMed/Medline, Web of Science, and Embase for articles published between 1990 and 2022. Any articles on the occupational respiratory health effects of dental dust were included. RESULTS The characterization and toxicity evaluation of dental dust show a correlation between dust exposure and respiratory system injury, and the possible pathogenic mechanism of dust is to cause lung injury and abnormal repair processes. The combination use of personal protective equipment and particle removal devices can effectively reduce the adverse health effects of dust exposure. CONCLUSIONS Dental dust should be considered an additional occupational hazard in dental practice. However, clinical data and scientific evidence on this topic are still scarce. Further research is required to quantify dust in the dental work environment and clarify its pathogenicity and potential toxicological pathways. Nonetheless, the prevention of dust exposure should become a consensus among dental practitioners. CLINICAL RELEVANCE This review provides dental practitioners with a comprehensive understanding and preventive advice on respiratory health problems associated with dust exposure.
Collapse
Affiliation(s)
- Jiaxin Ding
- grid.64924.3d0000 0004 1760 5735Hospital of Stomatology, Jilin University, Changchun, China
| | - Junxuan Li
- grid.64924.3d0000 0004 1760 5735Hospital of Stomatology, Jilin University, Changchun, China
| | - Junnan Qi
- grid.64924.3d0000 0004 1760 5735Hospital of Stomatology, Jilin University, Changchun, China
| | - Li Fu
- Department of Oral Implantology, Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130021, China.
| |
Collapse
|
10
|
Alvarenga MOP, Dias JMM, Lima BJLA, Gomes ASL, Monteiro GQM. The implementation of portable air-cleaning technologies in healthcare settings - a scoping review. J Hosp Infect 2023; 132:93-103. [PMID: 36521582 PMCID: PMC9744491 DOI: 10.1016/j.jhin.2022.12.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 11/07/2022] [Accepted: 12/02/2022] [Indexed: 12/15/2022]
Abstract
The COVID-19 pandemic revealed opportunities to improve prevention practices in healthcare settings, mainly related to the spread of airborne microbes (also known as bioaerosols). This scoping review aimed to map methodologies used to assess the implementation of portable air cleaners in healthcare settings, identify gaps, and propose recommendations for future research. The protocol was registered in the Open Science Framework and reported following the checklist provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analysis - an extension for Scoping Reviews (PRISMA-ScR) statement. The search strategy was performed in five databases and one grey literature source. At the last selection phase, 24 articles that fulfilled our inclusion criteria were summarized and disseminated. Of these, 17 studies were conducted between 2020 and 2022; one of them was a protocol of a multicentre randomized controlled trial. The outcomes measured among the studies include airborne microbe counts, airborne particle concentrations, and rate of infections/interventions. The leading healthcare settings assessed were dental clinics (28%), patient's wards (16%), operating rooms (16%), and intensive care units (12%). Most of the devices demonstrated a significant potential to mitigate the impact of bioaerosols. Although some indoor air quality parameters can influence the mechanics of aerosols, only a few studies controlled these parameters in their analyses. Future clinical research should assess the rate of infections through randomized controlled trials with long-term follow-up and large sample sizes to determine the clinical importance of the findings.
Collapse
Affiliation(s)
- M O P Alvarenga
- Dental School, Universidade de Pernambuco, Pernambuco, Brazil
| | - J M M Dias
- Analytical Chemistry Laboratory, Instituto de Tecnologia de Pernambuco, Pernambuco, Brazil
| | - B J L A Lima
- Microbiology Testing Laboratory, Instituto de Tecnologia de Pernambuco, Pernambuco, Brazil
| | - A S L Gomes
- Department of Physics and Graduate Program in Dentistry, Universidade Federal de Pernambuco, Pernambuco, Brazil
| | - G Q M Monteiro
- Dental School, Universidade de Pernambuco, Pernambuco, Brazil.
| |
Collapse
|
11
|
Revazova ZE, Lalieva ZE, Tsargasova MO, Belenchekov AA. [The spread of aerosols and splashes during the removal of dental deposits with an ultrasonic scaler]. STOMATOLOGIIA 2023; 102:21-24. [PMID: 38096390 DOI: 10.17116/stomat202310206221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
There is an increased prevalence of respiratory infections among dentists, which is associated with a heavily polluted breathing area in the dental office. Patients and dentists are at high risk of cross-infection due to the spread of aerosols in the form of droplets suspended in the air. The ultrasonic scaler is the largest source of aerosols and spatter in the dental office. Aerosols remain in the air for a long time even after the completion of a dental procedure and have a potential risk of inhalation. PURPOSE OF THE STUDY To evaluate the spatial distribution of aerosols and splashes during a dental appointment during ultrasonic dental treatment. MATERIAL AND METHODS The study was conducted on a mannequin equipped with phantom jaws, where dental plaque removal was simulated using an ultrasonic scaler filled with fluorescein. The amount of contamination was measured using a transparent grid with a square marking of 1 cm2. The grid was placed on top of a disk of filter paper and the area of contamination was measured by counting the number of soiled squares. If a square had at least 1 yellow area, then it was considered polluted. RESULTS Aerosols and splashes were distributed up to 60 cm from the head restraint. Aerosols can spread over more than 1 m. CONCLUSIONS The study showed the spread of aerosols and splashes during dental appointments. The risk of infection can be minimized by following simple protective measures.
Collapse
Affiliation(s)
- Z E Revazova
- A.I. Yevdokimov Moscow State University of Medicine and Dentistry of the Ministry of Healthcare of the Russian Federation, Moscow, Russia
| | - Z E Lalieva
- A.I. Yevdokimov Moscow State University of Medicine and Dentistry of the Ministry of Healthcare of the Russian Federation, Moscow, Russia
| | - M O Tsargasova
- A.I. Yevdokimov Moscow State University of Medicine and Dentistry of the Ministry of Healthcare of the Russian Federation, Moscow, Russia
| | - A A Belenchekov
- North Ossetian State University named after K.L. Khetagurov, Vladikavkaz, Russia
| |
Collapse
|
12
|
Liu Z, Yao G, Li Y, Huang Z, Jiang C, He J, Wu M, Liu J, Liu H. Bioaerosol distribution characteristics and potential SARS-CoV-2 infection risk in a multi-compartment dental clinic. BUILDING AND ENVIRONMENT 2022; 225:109624. [PMID: 36164582 PMCID: PMC9494923 DOI: 10.1016/j.buildenv.2022.109624] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 08/28/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
Dental clinics have a potential risk of infection, particularly during the COVID-19 pandemic. Multi-compartment dental clinics are widely used in general hospitals and independent clinics. This study utilised computational fluid dynamics to investigate the bioaerosol distribution characteristics in a multi-compartment dental clinic through spatiotemporal distribution, working area time-varying concentrations, and key surface deposition. The infection probability of SARS-CoV-2 for the dental staff and patients was calculated using the Wells-Riley model. In addition, the accuracy of the numerical model was verified by field measurements of aerosol concentrations performed during a clinical ultrasonic scaling procedure. The results showed that bioaerosols were mainly distributed in the compartments where the patients were treated. The average infection probability was 3.8% for dental staff. The average deposition number per unit area of the treatment chair and table are 28729 pcs/m2 and 7945 pcs/m2, respectively, which creates a possible contact transmission risk. Moreover, there was a certain cross-infection risk in adjacent compartments, and the average infection probability for patients was 0.84%. The bioaerosol concentrations of the working area in each compartment 30 min post-treatment were reduced to 0.07% of those during treatment, and the infection probability was <0.05%. The results will contribute to an in-depth understanding of the infection risk in multi-compartment dental clinics, forming feasible suggestions for management to efficiently support epidemic prevention and control in dental clinics.
Collapse
Affiliation(s)
- Zhijian Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Guangpeng Yao
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Yabin Li
- The Fifth Medical Center of PLA General Hospital, Beijing, 100039, China
| | - Zhenzhe Huang
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Chuan Jiang
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Junzhou He
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Minnan Wu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Jia Liu
- The Fifth Medical Center of PLA General Hospital, Beijing, 100039, China
| | - Haiyang Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| |
Collapse
|
13
|
Saveanu CI, Zetu IN, Scheuleac A, Saveanu AE, Romanec CL. A Cross-Sectional, Questionnaire-Based Survey on Air Infection Control among Romanian People. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12140. [PMID: 36231440 PMCID: PMC9566711 DOI: 10.3390/ijerph191912140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/20/2022] [Accepted: 09/21/2022] [Indexed: 06/16/2023]
Abstract
(1) Background: Infection control should be one of the main objectives in the comprehensive medical approach. (2) Methods: A cross-sectional study was conducted from June-July 2022. A questionnaire including 22 questions with multiple answers was applied online to 202 subjects selected at random. The questionnaire collected data on the subjects' knowledge about protective measures against airborne infections. For this study, a descriptive statistic was performed. Pearson's Chi-square test was used for data comparison. (3) Results: Only 61.39% (124) of the subjects consider that protective equipment is mandatory for the dental team, 40.10% (81) know to a very large extent and 44.06% (89) to a large extent that when talking, a respiratory infection can be transmitted. A rather large percentage of the subjects take into account the cost of the protective mask to a very large extent 39.60% (80). Only 30.20% (61) of the subjects would vaccinate to a very large extent and 24.75% (50) to a large extent against micro-organisms transmitted by air p > 0.05. (4) Conclusions: Most people know the aspects related to air decontamination, the priority being the promotion of control methods of airborne infections, and it is necessary to improve the level of knowledge on a large scale within the population.
Collapse
Affiliation(s)
- Catalina Iulia Saveanu
- Department of Surgicals, Faculty of Dental Medicine, University of Medicine and Pharmacy Grigore T Popa, 700115 Iasi, Romania
| | - Irina Nicoleta Zetu
- Department of Surgicals, Faculty of Dental Medicine, University of Medicine and Pharmacy Grigore T Popa, 700115 Iasi, Romania
| | - Alexandra Scheuleac
- Faculty of Dental Medicine, University of Medicine and Pharmacy Grigore T Popa, 700115 Iasi, Romania
| | | | - Cristian Liviu Romanec
- Faculty of Dental Medicine, University of Medicine and Pharmacy Grigore T Popa, 700115 Iasi, Romania
| |
Collapse
|
14
|
Fennelly M, Gallagher C, Harding M, Hellebust S, Wenger J, O'Sullivan N, O'Connor D, Prentice M. Real-time Monitoring of Aerosol Generating Dental Procedures. J Dent 2022; 120:104092. [PMID: 35304203 DOI: 10.1016/j.jdent.2022.104092] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 03/04/2022] [Accepted: 03/09/2022] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE We aimed to quantify aerosol concentrations produced during different dental procedures under different mitigation processes. METHOD Aerosol concentrations were measured by the Optical Particle Sensor (OPS) and Wideband Integrated Bioaerosol Sensor (WIBS) during routine, time-recorded dental procedures on a manikin head in a partitioned enclosure. Four different, standardised dental procedures were repeated in triplicate for three different mitigation measures. RESULT Both high-volume evacuation (HVE) and HVE plus extra-oral suction (LEV) eradicated all procedure-related aerosols, and the enclosure stopped procedure-related aerosols escaping. Aerosols recorded by the OPS and WIBS were 84 and 16-fold higher than background levels during tooth 16 FDI notation (UR6) drilling, and 11 and 24-fold higher during tooth 46 FDI notation (LR6) drilling, respectively. Ultrasonic scaling around the full lower arch (CL) or the full upper arch (CU) did not generate detectable aerosols with mitigation applied. Without mitigation the largest concentration of inhalable particles during procedures observed by the WIBS and OPS was during LR6 (139/cm3) and UR6 (28/cm3) drilling, respectively. Brief aerosol bursts were recorded during drilling procedures with HVE, these did not occur with LEV, suggesting LEV provides protection against operator errors. Variation was observed in necessary fallow times (49 - 280 minutes) without mitigation, while no particles remained airborne when mitigation was utilised. CONCLUSION This data demonstrates that correctly positioned HVE or LEV is effective in preventing airborne spread and persistence of inhalable particles originating from dental AGPs. Additionally, a simple enclosure restricts the spread of aerosols outside of the operating area. CLINICAL SIGNIFICANCE Employing correctly positioned HVE and LEV in non-mechanically ventilated clinics can prevent the dispersal and persistence of inhalable airborne particles during dental AGPs. Moreover, using enclosures have the additive effect of restricting aerosol spread outside of an operating area.
Collapse
Affiliation(s)
- Mehael Fennelly
- School of Chemistry and Environmental Research Institute, University College Cork; Department of Pathology, University College Cork.
| | | | - Mairead Harding
- University Dental School & Hospital, University College Cork; Oral Health Services Research Centre, University College Cork
| | - Stig Hellebust
- School of Chemistry and Environmental Research Institute, University College Cork
| | - John Wenger
- School of Chemistry and Environmental Research Institute, University College Cork
| | - Niall O'Sullivan
- School of Chemistry and Environmental Research Institute, University College Cork
| | | | - Michael Prentice
- Department of Pathology, University College Cork; APC Microbiome Institute, University College Cork
| |
Collapse
|
15
|
Ooi CC, Suwardi A, Ou Yang ZL, Xu G, Tan CKI, Daniel D, Li H, Ge Z, Leong FY, Marimuthu K, Ng OT, Lim SB, Lim P, Mak WS, Cheong WCD, Loh XJ, Kang CW, Lim KH. Risk assessment of airborne COVID-19 exposure in social settings. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:087118. [PMID: 34552314 PMCID: PMC8450907 DOI: 10.1063/5.0055547] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 08/09/2021] [Indexed: 05/04/2023]
Abstract
The COVID-19 pandemic has led to many countries oscillating between various states of lock-down as they seek to balance keeping the economy and essential services running and minimizing the risk of further transmission. Decisions are made about which activities to keep open across a range of social settings and venues guided only by ad hoc heuristics regarding social distancing and personal hygiene. Hence, we propose the dual use of computational fluid dynamic simulations and surrogate aerosol measurements for location-specific assessment of risk of infection across different real-world settings. We propose a 3-tiered risk assessment scheme to facilitate classification of scenarios into risk levels based on simulations and experiments. Threshold values of <54 and >840 viral copies and <5% and >40% of original aerosol concentration are chosen to stratify low, medium, and high risk. This can help prioritize allowable activities and guide implementation of phased lockdowns or re-opening. Using a public bus in Singapore as a case study, we evaluate the relative risk of infection across scenarios such as different activities and passenger positions and demonstrate the effectiveness of our risk assessment methodology as a simple and easily interpretable framework. For example, this study revealed that the bus's air-conditioning greatly influences dispersion and increases the risk of certain seats and that talking can result in similar relative risk to coughing for passengers around an infected person. Both numerical and experimental approaches show similar relative risk levels with a Spearman's correlation coefficient of 0.74 despite differing observables, demonstrating applicability of this risk assessment methodology to other scenarios.
Collapse
Affiliation(s)
- Chin Chun Ooi
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Ady Suwardi
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, Singapore 138634
| | - Zhong Liang Ou Yang
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - George Xu
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Chee Kiang Ivan Tan
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, Singapore 138634
| | - Dan Daniel
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, Singapore 138634
| | - Hongying Li
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Zhengwei Ge
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Fong Yew Leong
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Kalisvar Marimuthu
- National Centre for Infectious Diseases, Tan Tock Seng Hospital, 16 Jalan Tan Tock Seng, Singapore 308443
| | - Oon Tek Ng
- National Centre for Infectious Diseases, Tan Tock Seng Hospital, 16 Jalan Tan Tock Seng, Singapore 308443
| | - Shin Bin Lim
- Ministry of Health Singapore, College of Medicine Building, 16 College Road, Singapore 169854
| | - Peter Lim
- Land Transport Authority, 1 Hampshire Road, Singapore 219428
| | - Wai Siong Mak
- Land Transport Authority, 1 Hampshire Road, Singapore 219428
| | - Wun Chet Davy Cheong
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, Singapore 138634
| | - Xian Jun Loh
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, Singapore 138634
| | - Chang Wei Kang
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| | - Keng Hui Lim
- Institute of High Performance Computing, Agency for Science, Technology and Research, 1 Fusionopolis Way, Singapore 138632
| |
Collapse
|