1
|
Lipszyc AC, Walker SCD, Beech AP, Wilding H, Akhlaghi H. Predicting Fluid Responsiveness Using Carotid Ultrasound in Mechanically Ventilated Patients: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Anesth Analg 2024; 138:1174-1186. [PMID: 38289868 DOI: 10.1213/ane.0000000000006820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
BACKGROUND A noninvasive and accurate method of determining fluid responsiveness in ventilated patients would help to mitigate unnecessary fluid administration. Although carotid ultrasound has been previously studied for this purpose, several studies have recently been published. We performed an updated systematic review and meta-analysis to evaluate the accuracy of carotid ultrasound as a tool to predict fluid responsiveness in ventilated patients. METHODS Studies eligible for review investigated the accuracy of carotid ultrasound parameters in predicting fluid responsiveness in ventilated patients, using sensitivity and specificity as markers of diagnostic accuracy (International Prospective Register of Systematic Reviews [PROSPERO] CRD42022380284). All included studies had to use an independent method of determining cardiac output and exclude spontaneously ventilated patients. Six bibliographic databases and 2 trial registries were searched. Medline, Embase, Emcare, APA PsycInfo, CINAHL, and the Cochrane Library were searched on November 4, 2022. Clinicaltrials.gov and Australian New Zealand Clinical Trials Registry were searched on February 24, 2023. Results were pooled, meta-analysis was conducted where possible, and hierarchical summary receiver operating characteristic models were used to compare carotid ultrasound parameters. Bias and evidence quality were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool and the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) guidelines. RESULTS Thirteen prospective clinical studies were included (n = 648 patients), representing 677 deliveries of volume expansion, with 378 episodes of fluid responsiveness (58.3%). A meta-analysis of change in carotid Doppler peak velocity (∆CDPV) yielded a sensitivity of 0.79 (95% confidence interval [CI], 0.74-0.84) and a specificity of 0.85 (95% CI, 0.76-0.90). Risk of bias relating to recruitment methodology, the independence of index testing to reference standards and exclusionary clinical criteria were evaluated. Overall quality of evidence was low. Study design heterogeneity, including a lack of clear parameter cutoffs, limited the generalizability of our results. CONCLUSIONS In this meta-analysis, we found that existing literature supports the ability of carotid ultrasound to predict fluid responsiveness in mechanically ventilated adults. ∆CDPV may be an accurate carotid parameter in certain contexts. Further high-quality studies with more homogenous designs are needed to further validate this technology.
Collapse
Affiliation(s)
- Adam C Lipszyc
- From the Department of Anaesthesia and Acute Pain Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia
| | - Samuel C D Walker
- Department of Emergency Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia
- Department of Medical Education, University of Melbourne, Melbourne, Victoria, Australia
| | - Alexander P Beech
- From the Department of Anaesthesia and Acute Pain Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia
| | - Helen Wilding
- Library Service, St Vincent's Hospital, Melbourne, Victoria, Australia
| | - Hamed Akhlaghi
- Department of Emergency Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia
- Department of Medical Education, University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
2
|
Bilgili B, Saracoglu A, Saracoglu KT, Ratajczyk P, Kararmaz A. The Reliability of Carotid Artery Doppler Ultrasonography Indices in Predicting Fluid Responsiveness during Surgery for Geriatric Patients: A Prospective, Observational Study. Healthcare (Basel) 2024; 12:783. [PMID: 38610205 PMCID: PMC11011830 DOI: 10.3390/healthcare12070783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/02/2024] [Accepted: 04/02/2024] [Indexed: 04/14/2024] Open
Abstract
BACKGROUND The reliability of determining fluid responsiveness during surgery in geriatric patients is challenging. Our primary outcome was to determine the reliability of Corrected Flow Time (FTc) in predicting fluid responsiveness. METHODS Elderly patients undergoing major surgery under general anesthesia were included. Measurements of common carotid artery diameter, velocity time integral, and systolic flow time (FT) were performed before and after a fluid challenge. FTc and carotid blood flow (CBF) were subsequently calculated. RESULTS The median change in carotid diameter was significantly higher in the fluid-responder (R) compared to the non-responder (NR) (6.51% vs. 0.65%, p = 0.049). The median change in CBF was notably higher in R compared to NR (30.04% vs. 9.72%, p = 0.024). Prior to the fluid challenge, systolic FT was significantly shorter in R than NR (285 ms vs. 315 ms, p = 0.027), but after the fluid challenge, these measurements became comparable among the groups. The change in systolic FT was higher in R (15.38% vs. 7.49%, p = 0.027). FTc and the change in FTc exhibited similarities among the groups at all study time points. Receiver operating characteristic analysis demonstrated an area under the curve of 0.682 (95% CI: 0.509-0.855, p = 0.039) for carotid diameter, 0.710 (95% CI: 0.547-0.872, p = 0.011) for CBF, 0.706 (95% CI: 0.540-0.872, p = 0.015) for systolic FT, and 0.580 (95% CI = 0.389-0.770, p = 0.413) for FTc. CONCLUSIONS In geriatric patients, potential endothelial changes in the carotid artery may influence the dynamic markers of fluid responsiveness. Despite the demonstrated effectiveness of FTc in predicting fluid responsiveness in the general population, this study underscores the limited reliability of carotid Doppler ultrasonography indices for prediction in a geriatric patient population.
Collapse
Affiliation(s)
- Beliz Bilgili
- Department of Anesthesiology and Intensive Care, Marmara University Pendik Training and Research Hospital, 34899 Istanbul, Turkey; (B.B.); (A.K.)
| | - Ayten Saracoglu
- Department of Anesthesiology, Intensive Care and Perioperative Medicine, Aisha bint Hamad Al Attiah Hospital, Hamad Medical Corporation, Doha P.O. Box 3050, Qatar;
- College of Medicine, Qatar University, Doha P.O. Box 2713, Qatar
| | - Kemal T. Saracoglu
- College of Medicine, Qatar University, Doha P.O. Box 2713, Qatar
- Department of Anesthesiology, Intensive Care and Perioperative Medicine, Hazm Mebaireek General Hospital, Hamad Medical Corporation, Doha P.O. Box 3050, Qatar
| | - Pawel Ratajczyk
- Department of Anesthesiology and Intensive Therapy, Medical University of Lodz, 90-419 Lodz, Poland
| | - Alper Kararmaz
- Department of Anesthesiology and Intensive Care, Marmara University Pendik Training and Research Hospital, 34899 Istanbul, Turkey; (B.B.); (A.K.)
| |
Collapse
|
3
|
Zhou K, Ran S, Guo Y, Ye H. CAROTID ARTERY ULTRASOUND FOR ASSESSING FLUID RESPONSIVENESS IN PATIENTS UNDERGOING MECHANICAL VENTILATION WITH LOW TIDAL VOLUME AND PRESERVED SPONTANEOUS BREATHING. Shock 2024; 61:360-366. [PMID: 38117132 DOI: 10.1097/shk.0000000000002288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
ABSTRACT Objective : This study aimed to investigate whether changes in carotid artery corrected flow time (ΔFTc bolus ) and carotid artery peak flow velocity respiratory variation (Δ V peak bolus ) induced by the fluid challenge could reliably predict fluid responsiveness in mechanically ventilated patients with a tidal volume < 8 mL/kg Predicted Body Weight while preserving spontaneous breathing. Methods : Carotid artery corrected flow time, Δ V peak, and hemodynamic data were measured before and after administration of 250 mL crystalloids. Fluid responsiveness was defined as a 10% or more increase in stroke volume index as assessed by noninvasive cardiac output monitoring after the fluid challenge. Results : A total of 43 patients with acute circulatory failure were enrolled in this study. Forty-three patients underwent a total of 60 fluid challenges. The ΔFTc bolus and Δ V peak bolus showed a significant difference between the fluid responsiveness positive group (n = 35) and the fluid responsiveness negative group (n = 25). Spearman correlation test showed that ΔFTc bolus and Δ V peak bolus with the relative increase in stroke volume index after fluid expansion ( r = 0.5296, P < 0.0001; r = 0.3175, P = 0.0135). Multiple logistic regression analysis demonstrated that ΔFTc bolus and Δ V peak bolus were significantly correlated with fluid responsiveness in patients with acute circulatory failure. The areas under the receiver operating characteristic curves of ΔFTc bolus and Δ V peak bolus for predicting fluid responsiveness were 0.935 and 0.750, respectively. The optimal cutoff values of ΔFTc bolus and Δ V peak bolus were 0.725 (sensitivity = 97.1%, specificity = 84%) and 4.21% (sensitivity = 65.7%, specificity = 80%), respectively. Conclusion : In mechanically ventilated patients with a tidal volume < 8 mL/kg while preserving spontaneous breathing, ΔFTc bolus and Δ V peak bolus could predict fluid responsiveness. The predictive performance of ΔFTc bolus was superior to Δ V peak bolus .
Collapse
Affiliation(s)
- Kefan Zhou
- Department of Intensive Care Medicine, Changshu Hospital Affiliated to Soochow University, Changshu No. 1 People's Hospital, Suzhou, China
| | | | | | | |
Collapse
|
4
|
Kerrebijn I, Atwi S, Elfarnawany M, Eibl AM, Eibl JK, Taylor JL, Kim CH, Johnson BD, Kenny JÉS. The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation. Acute Crit Care 2024; 39:162-168. [PMID: 38476069 PMCID: PMC11002613 DOI: 10.4266/acc.2023.01095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 12/14/2023] [Accepted: 01/23/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. METHODS Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. RESULTS In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. CONCLUSIONS There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
Collapse
Affiliation(s)
| | | | | | - Andrew M. Eibl
- Flosonics Medical, Toronto, ON, Canada
- Health Sciences North Research Institute, Sudbury, ON, Canada
| | - Joseph K. Eibl
- Flosonics Medical, Toronto, ON, Canada
- Health Sciences North Research Institute, Sudbury, ON, Canada
- Northern Ontario School of Medicine University, Sudbury, ON, Canada
| | - Jenna L. Taylor
- Human Integrative and Environmental Physiology Laboratory, Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
- Physiology and Ultrasound Laboratory in Science and Exercise, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Australia
| | - Chul-Ho Kim
- Human Integrative and Environmental Physiology Laboratory, Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Bruce D. Johnson
- Human Integrative and Environmental Physiology Laboratory, Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Jon-Émile S. Kenny
- Flosonics Medical, Toronto, ON, Canada
- Health Sciences North Research Institute, Sudbury, ON, Canada
| |
Collapse
|
5
|
Jin G, Liu F, Yang Y, Chen J, Wen Q, Wang Y, Yu L, He J. Carotid blood flow changes following a simulated end-inspiratory occlusion maneuver measured by ultrasound can predict hypotension after the induction of general anesthesia: an observational study. BMC Anesthesiol 2024; 24:13. [PMID: 38172775 PMCID: PMC10763470 DOI: 10.1186/s12871-023-02393-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND The primary purpose of this study was to investigate the predictive value of alterations in cervical artery hemodynamic parameters induced by a simulated end-inspiratory occlusion test (sEIOT) measured by ultrasound for predicting postinduction hypotension (PIH) during general anesthesia. METHODS Patients undergoing gastrointestinal tumor resection under general anesthesia were selected for this study. Ultrasound has been utilized to assess hemodynamic parameters in carotid artery blood flow before induction, specifically focusing on variations in corrected flow time (ΔFTc) and peak blood flow velocity (ΔCDPV), both before and after sEIOT. Anesthesia was induced by midazolam, sufentanil, propofol, and rocuronium, and blood pressure (BP) and heart rate (HR) were recorded within the first 10 min following endotracheal intubation. PIH was defined as fall in systolic blood pressure (SBP) or mean arterial pressure (MAP) by > 30% of baseline or MAP to < 60 mm Hg. RESULTS The area under the receiver operating characteristic curves (AUC) for carotid artery ΔFTc was 0.88 (95%CI, 0.81 to 0.96; P < 0.001), and the optimal cutoff value was -16.57%, with a sensitivity of 91.4% and specificity of 77.60%. The gray zone for carotid artery ΔFTc was -16.34% to -15.36% and included 14% of the patients. The AUC for ΔCDPV was 0.54, with an optimal cutoff value of -1.47%. The sensitivity and specificity were calculated as 55.20% and 57.10%, respectively. CONCLUSION The corrected blood flow time changes in the carotid artery induced by sEIOT can predict hypotension following general anesthesia-induced hypotension, wherein ΔFTc less than 16.57% is the threshold. TRIAL REGISTRATION Chinese Clinical Trial Registry ( www.chictr.org.cn ; 20/06/2023; ChiCTR2300072632).
Collapse
Affiliation(s)
- Guangshan Jin
- School of Anesthesiology, Xuzhou Medical University, Jiangsu, China
| | - Fuqiang Liu
- Department of Anesthesiology, Jiangsu Cancer Hospital, The Affricated Cancer Hospital of Nanjing Medical University, Jiangsu, China
| | - Yiwen Yang
- School of Anesthesiology, Xuzhou Medical University, Jiangsu, China
| | - Jiahui Chen
- School of Anesthesiology, Xuzhou Medical University, Jiangsu, China
| | - Qian Wen
- Department of Anesthesiology, Jiangsu Cancer Hospital, The Affricated Cancer Hospital of Nanjing Medical University, Jiangsu, China
| | - Yudong Wang
- School of Anesthesiology, Xuzhou Medical University, Jiangsu, China
| | - Ling Yu
- Department of Ultrasound, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Jiangsu, China
| | - Jianhua He
- School of Anesthesiology, Xuzhou Medical University, Jiangsu, China.
- Department of Anesthesiology, Jiangsu Cancer Hospital, The Affricated Cancer Hospital of Nanjing Medical University, Jiangsu, China.
| |
Collapse
|
6
|
Kenny JES, Prager R, Rola P, McCulloch G, Atwi S, Munding CE, Eibl JK, Haycock K. Inferior Vena Caval Measures Do Not Correlate with Carotid Artery Corrected Flow Time Change Measured Using a Wireless Doppler Patch in Healthy Volunteers. Diagnostics (Basel) 2023; 13:3591. [PMID: 38066832 PMCID: PMC10706625 DOI: 10.3390/diagnostics13233591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 11/27/2023] [Accepted: 11/29/2023] [Indexed: 10/16/2024] Open
Abstract
(1) Background: The inspiratory collapse of the inferior vena cava (IVC), a non-invasive surrogate for right atrial pressure, is often used to predict whether a patient will augment stroke volume (SV) in response to a preload challenge. There is a correlation between changing stroke volume (SV∆) and corrected flow time of the common carotid artery (ccFT∆). (2) Objective: We studied the relationship between IVC collapsibility and ccFT∆ in healthy volunteers during preload challenges. (3) Methods: A prospective, observational, pilot study in euvolemic, healthy volunteers with no cardiovascular history was undertaken in a local physiology lab. Using a tilt-table, we studied two degrees of preload augmentation from (a) supine to 30-degrees head-down and (b) fully-upright to 30-degrees head down. In the supine position, % of IVC collapse with respiration, sphericity index and portal vein pulsatility was calculated. The common carotid artery Doppler pulse was continuously captured using a wireless, wearable ultrasound system. (4) Results: Fourteen subjects were included. IVC % collapse with respiration ranged between 10% and 84% across all subjects. Preload responsiveness was defined as an increase in ccFT∆ of at least 7 milliseconds. A total of 79% (supine baseline) and 100% (head-up baseline) of subjects were preload-responsive. No supine venous measures (including IVC % collapse) were significantly related to ccFT∆. (5) Conclusions: From head-up baseline, 100% of healthy subjects were 'preload-responsive' as per the ccFT∆. Based on the 42% and 25% IVC collapse thresholds in the supine position, only 50% and 71% would have been labeled 'preload-responsive'.
Collapse
Affiliation(s)
- Jon-Emile S. Kenny
- Health Sciences North Research Institute, Sudbury, ON P3E 2H3, Canada
- Flosonics Medical, Toronto, ON P3E 2H2, Canada
| | - Ross Prager
- Division of Critical Care Medicine, Western University, London, ON N6A 3K7, Canada
| | - Philippe Rola
- Intensive Care Unit, Santa Cabrini Hospital, Montreal, QC H1T 1P7, Canada
| | | | - Sarah Atwi
- Flosonics Medical, Toronto, ON P3E 2H2, Canada
| | | | - Joseph K. Eibl
- Health Sciences North Research Institute, Sudbury, ON P3E 2H3, Canada
- Flosonics Medical, Toronto, ON P3E 2H2, Canada
- Northern Ontario School of Medicine, Sudbury, ON P3E 2C6, Canada
| | - Korbin Haycock
- Department of Emergency Medicine, Riverside University Health System Medical Center, Moreno Valley, CA 92555, USA
| |
Collapse
|
7
|
Hung KC, Huang YT, Tsai WW, Tan PH, Wu JY, Huang PY, Liu TH, Chen IW, Sun CK. Diagnostic Efficacy of Carotid Ultrasound for Predicting the Risk of Perioperative Hypotension or Fluid Responsiveness: A Meta-Analysis. Diagnostics (Basel) 2023; 13:2290. [PMID: 37443683 DOI: 10.3390/diagnostics13132290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 06/28/2023] [Accepted: 07/03/2023] [Indexed: 07/15/2023] Open
Abstract
Despite the acceptance of carotid ultrasound for predicting patients' fluid responsiveness in critical care and anesthesia, its efficacy for predicting hypotension and fluid responsiveness remains unclear in the perioperative setting. Electronic databases were searched from inception to May 2023 to identify observational studies focusing on the use of corrected blood flow time (FTc) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak) for assessing the risks of hypotension and fluid responsiveness. Using FTc as a predictive tool (four studies), the analysis yielded a pooled sensitivity of 0.82 (95% confidence interval (CI): 0.72 to 0.89) and specificity of 0.94 (95% CI: 0.88 to 0.97) for the risk of hypotension (area under curve (AUC): 0.95). For fluid responsiveness, the sensitivity and specificity of FTc were 0.79 (95% CI: 0.72 to 0.84) and 0.81 (95% CI: 0.75 to 0.86), respectively (AUC: 0.87). In contrast, the use of ΔVpeak to predict the risk of fluid responsiveness showed a pooled sensitivity of 0.76 (95% CI: 0.63 to 0.85) and specificity of 0.74 (95% CI: 0.66 to 0.8) (AUC: 0.79). The current meta-analysis provides robust evidence supporting the high diagnostic accuracy of FTc in predicting perioperative hypotension and fluid responsiveness, which requires further studies for verification.
Collapse
Affiliation(s)
- Kuo-Chuan Hung
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung City 80424, Taiwan
- Department of Anesthesiology, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - Yen-Ta Huang
- Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan City 70101, Taiwan
| | - Wen-Wen Tsai
- Department of Neurology, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - Ping-Heng Tan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung City 80424, Taiwan
- Department of Anesthesiology, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - Jheng-Yan Wu
- Department of Nutrition, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - Po-Yu Huang
- Department of Internal Medicine, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - Ting-Hui Liu
- Department of General Internal Medicine, Chi Mei Medical Center, Tainan City 71004, Taiwan
| | - I-Wen Chen
- Department of Anesthesiology, Chi Mei Medical Center, Liouying, Tainan City 73657, Taiwan
| | - Cheuk-Kwan Sun
- Department of Emergency Medicine, E-Da Dachang Hospital, I-Shou University, Kaohsiung City 82445, Taiwan
- School of Medicine for International Students, College of Medicine, I-Shou University, Kaohsiung City 82445, Taiwan
| |
Collapse
|
8
|
Suriani I, van Houte J, de Boer EC, van Knippenberg L, Manzari S, Mischi M, Bouwman RA. Carotid Doppler ultrasound for non-invasive haemodynamic monitoring: a narrative review. Physiol Meas 2023; 43. [PMID: 36179705 DOI: 10.1088/1361-6579/ac96cb] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 09/30/2022] [Indexed: 11/11/2022]
Abstract
Objective.Accurate haemodynamic monitoring is the cornerstone in the management of critically ill patients. It guides the optimization of tissue and organ perfusion in order to prevent multiple organ failure. In the past decades, carotid Doppler ultrasound (CDU) has been explored as a non-invasive alternative for long-established invasive haemodynamic monitoring techniques. Considering the large heterogeneity in reported studies, we conducted a review of the literature to clarify the current status of CDU as a haemodynamic monitoring tool.Approach.In this article, firstly an overview is given of the equipment and workflow required to perform a CDU exam in clinical practice, the limitations and technical challenges potentially faced by the CDU sonographer, and the cerebrovascular mechanisms that may influence CDU measurement outcomes. The following chapter describes alternative techniques for non-invasive haemodynamic monitoring, detailing advantages and limitations compared to CDU. Next, a comprehensive review of the literature regarding the use of CDU for haemodynamic monitoring is presented. Furthermore, feasibility aspects, training requirements and technical developments of CDU are addressed.Main results.Based on the outcomes of these studies, we assess the applicability of CDU-derived parameters within three clinical domains (cardiac output, volume status, and fluid responsiveness), and amongst different patient groups. Finally, recommendations are provided to improve the quality and standardization of future research and clinical practice in this field.Significance.Although CDU is not yet interchangeable with invasive 'gold standard' cardiac output monitoring, the present work shows that certain CDU-derived parameters prove promising in the context of functional haemodynamic monitoring.
Collapse
Affiliation(s)
- Irene Suriani
- Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands
| | - Joris van Houte
- Catharina Hospital Michelangelolaan 2, 5623 EJ Eindhoven, The Netherlands
| | - Esmée C de Boer
- Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands
| | - Luuk van Knippenberg
- Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands
| | - Sabina Manzari
- Philips Research High Tech Campus 34, 5656 AE Eindhoven, The Netherlands
| | - Massimo Mischi
- Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands
| | - R Arthur Bouwman
- Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands.,Catharina Hospital Michelangelolaan 2, 5623 EJ Eindhoven, The Netherlands
| |
Collapse
|
9
|
Kenny JÉS, Gibbs SO, Johnston D, Yang Z, Hofer LM, Elfarnawany M, Eibl JK, Johnson A, Buecker AJ, Lau VC, Kemp BO. The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound. J Intensive Care 2023; 11:7. [PMID: 36793079 PMCID: PMC9933329 DOI: 10.1186/s40560-023-00655-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 02/06/2023] [Indexed: 02/17/2023] Open
Abstract
BACKGROUND Little data exist on the time spent by emergency department (ED) personnel providing intravenous (IV) fluid to 'responsive' versus 'unresponsive' patients. METHODS A prospective, convenience sample of adult ED patients was studied; patients were enrolled if preload expansion was indicated for any reason. Using a novel, wireless, wearable ultrasound, carotid artery Doppler was obtained before and throughout a preload challenge (PC) prior to each bag of ordered IV fluid. The treating clinician was blinded to the results of the ultrasound. IV fluid was deemed 'effective' or 'ineffective' based on the greatest change in carotid artery corrected flow time (ccFT∆) during the PC. The duration, in minutes, of each bag of IV fluid administered was recorded. RESULTS 53 patients were recruited and 2 excluded for Doppler artifact. There were 86 total PCs included in the investigation comprising 81.7 L of administered IV fluid. 19,667 carotid Doppler cardiac cycles were analyzed. Using ccFT∆ ≥ + 7 ms to discriminate 'physiologically effective' from 'ineffective' IV fluid, we observed that 54 PCs (63%) were 'effective', comprising 51.7 L of IV fluid, whereas, 32 (37%) were 'ineffective' comprising 30 L of IV fluid. 29.75 total hours across all 51 patients were spent in the ED providing IV fluids categorized as 'ineffective.' CONCLUSIONS We report the largest-known carotid artery Doppler analysis (i.e., roughly 20,000 cardiac cycles) in ED patients requiring IV fluid expansion. A clinically significant amount of time was spent providing physiologically ineffective IV fluid. This may represent an avenue to improve ED care efficiency.
Collapse
Affiliation(s)
- Jon-Émile S. Kenny
- grid.420638.b0000 0000 9741 4533Health Sciences North Research Institute, 56 Walford Road, Sudbury, ON P3E2H3 Canada ,Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Stanley O. Gibbs
- Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Delaney Johnston
- Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Zhen Yang
- Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Lisa M. Hofer
- Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Mai Elfarnawany
- Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada
| | - Joseph K. Eibl
- grid.420638.b0000 0000 9741 4533Health Sciences North Research Institute, 56 Walford Road, Sudbury, ON P3E2H3 Canada ,Flosonics Medical 325 W. Front Street, Toronto, ON M5V2Y1 Canada ,grid.436533.40000 0000 8658 0974Northern Ontario School of Medicine, 935 Ramsey Lake Road, Sudbury, ON P3E2C6 Canada
| | - Amanda Johnson
- grid.416495.b0000 0004 0383 0587OSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL 61637 USA
| | - Anthony J. Buecker
- grid.416495.b0000 0004 0383 0587OSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL 61637 USA
| | - Vivian C. Lau
- grid.416495.b0000 0004 0383 0587OSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL 61637 USA
| | - Benjamin O. Kemp
- grid.416495.b0000 0004 0383 0587OSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL 61637 USA
| |
Collapse
|
10
|
Chen Y, Liu Z, Fang J, Xie Y, Zhang M, Yang J. Correlation of carotid corrected flow time and respirophasic variation in blood flow peak velocity with stroke volume variation in elderly patients under general anaesthesia. BMC Anesthesiol 2022; 22:246. [PMID: 35927621 PMCID: PMC9351080 DOI: 10.1186/s12871-022-01792-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 07/25/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Accurate assessment of volume responsiveness in elderly patients is important as it may reduce the risk of post-operative complications and enhance surgical recovery. This study evaluated the utility of two Doppler ultrasound-derived parameters, the carotid corrected flow time (FTc) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak), to predict volume responsiveness in elderly patients under general anaesthesia. METHODS A total of 97 elderly patients undergoing elective abdominal surgery under general anaesthesia were enrolled in this prospective observational study. After entering the operating room, all patients underwent radial artery puncture connected with a LiDCO device to measure stroke volume variation (SVV), and fluid therapy was performed after anaesthesia induction. Patients were classified as responders if SVV ≥ 13% before fluid challenge and nonresponders if SVV < 13%. The FTc, ΔVpeak, SVV and haemodynamic data were measured by ultrasound at baseline (T0) and before (T1) and after (T2) fluid challenge. The correlations between the Doppler ultrasound-derived parameters and SVV were analysed, and the receiver operating characteristic (ROC) curves was computed to characterize both FTc and ΔVpeak as measures of volume responsiveness in elderly patients. RESULTS Forty-one (42.3%) patients were fluid responders. Carotid FTc before fluid challenge was negatively correlated with SVV before fluid challenge (r = -0.77; P < 0.01), and ΔVpeak was positively correlated with SVV (r = 0.72; P < 0.01). FTc and ΔVpeak predicted SVV ≥ 13% after general anaesthesia in elderly patients, with areas under the receiver operating characteristic curves (AUROCs) of 0.811 [95% confidence interval (CI), 0.721-0.900; P < 0.001] and 0.781 (95% CI, 0.686-0.875; P < 0.001), respectively. The optimal cut-off values of FTc and ΔVpeak to predict SVV ≥ 13% were 340.74 ms (sensitivity of 76.8%; specificity of 80.5%) and 11.69% (sensitivity of 78.0%; specificity of 67.9%), respectively. CONCLUSIONS There was a good correlation between carotid artery ultrasound parameters and SVV. FTc predicted fluid responsiveness better than ΔVpeak in elderly patients during general anaesthesia. Further study is needed before these parameters can be recommended for clinical application. TRIAL REGISTRATION www.chictr.org.cn (ChiCTR2000031193); registered 23 March 2020.
Collapse
Affiliation(s)
- Yu Chen
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China
| | - Ziyou Liu
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China
| | - Jun Fang
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China
| | - Yanhu Xie
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China
| | - Min Zhang
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China
| | - Jia Yang
- Department of Anaesthesiology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Sciences and Technology of China, Hefei, 230001, Anhui, China.
| |
Collapse
|