1
|
Qatomah A, Aihara H. Colorectal endoscopic submucosal dissection in the USA: The current state and future perspectives. DEN OPEN 2025; 5:e394. [PMID: 38915785 PMCID: PMC11194299 DOI: 10.1002/deo2.394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/16/2024] [Accepted: 05/27/2024] [Indexed: 06/26/2024]
Abstract
Endoscopic submucosal dissection (ESD) is a transformative advancement in the endoscopic management of superficial gastrointestinal lesions. Initially conceived for the treatment of early gastric cancer, ESD has demonstrated proficiency in achieving en-bloc resection of superficial gastrointestinal lesions. ESD has experienced widespread acceptance in Japan and East Asia; however, its adoption in the USA remains delayed. This initial hesitancy could be attributed to procedural complexity and training demands; nonetheless, recently, ESD has been gaining popularity in the USA. This is due to the advancements in endoscopic technology, tailored training programs, and cumulative evidence regarding the efficacy and safety of ESDs. This review aimed to deliberate the historical progress, current implementation, and prospective trajectory of ESDs in the USA. With ongoing clinical research, technological integration, and educational efforts, ESD is likely to become the gold standard for managing large gastrointesitinal lesions. This progress marks an imperative step toward less invasive, more precise, and patient-centric approaches regarding advanced therapeutic endoscopy in the USA.
Collapse
Affiliation(s)
- Abdulrahman Qatomah
- Division of Gastroenterology and HepatologyMcGill University Health CenterMontrealCanada
- Division of Gastroenterology and HepatologyKing Faisal Specialist Hospital and Research CenterJeddahSaudi Arabia
| | - Hiroyuki Aihara
- Division of Gastroenterology, Hepatology and EndoscopyBrigham and Women's Hospital, Harvard Medical SchoolBostonMassachusettsUSA
| |
Collapse
|
2
|
Nomura T, Sugimoto S, Temma T, Oyamada J, Ito K, Kamei A. Reopenable clip-over-the-line method for closing large mucosal defects following colorectal endoscopic submucosal dissection: A feasibility study. Endosc Int Open 2023; 11:E697-E702. [PMID: 37564328 PMCID: PMC10411209 DOI: 10.1055/a-2095-0033] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 05/09/2023] [Indexed: 08/12/2023] Open
Abstract
Background and study aims Complete closure of large defects after colorectal endoscopic submucosal dissection (ESD) can be problematic, especially in challenging areas or lesions larger than half the lumen circumference. We report a reopenable clip-over-the-line method for such defects and aim to investigate its feasibility through a case series. Patients and methods We retrospectively evaluated data from 30 consecutive patients who underwent ESD with defect closure using the reopenable clip-over-the-line method between October 2020 and September 2022. This method requires the first clip-with-line grasp of the oral side's defect edge and muscle layer. The next reopenable clip (with a line fed through a hole in the reopenable clip tooth) is placed on the opposing mucosal defect edge and muscle layer. This process is repeated until complete closure. The primary study outcome was the rate of complete mucosal defect closure. We also reported post-procedure bleeding or perforation. Results The median dimensions of the resected specimens were 45 mm (range, 35-70) by 39 mm (range, 29-60). Complete closure was achieved for all defects, including nine rectal defects, of which three bordered the anal verge. Of the 30 defects included in this study, nine were larger than half the lumen circumference. The median closure time was 25 minutes (range, 14-52), and the median clip number was 17 (range, 9-42). No post-procedure bleeding or perforation occurred. Conclusions The reopenable clip-over-the-line method is a feasible technique for the complete closure of large colorectal defects after endoscopic submucosal dissection, regardless of location.
Collapse
Affiliation(s)
- Tatsuma Nomura
- Gastroenterology, Ise Red Cross Hospital, Ise-shi, Japan
- Gastroenterology, Mie Prefectural Shima Hospital, Shima-shi, Japan
| | | | - Taishi Temma
- Gastroenterology, Ise Red Cross Hospital, Ise-shi, Japan
| | - Jun Oyamada
- Gastroenterology, Ise Red Cross Hospital, Ise-shi, Japan
| | - Keiichi Ito
- Gastroenterology, Mie Prefectural Shima Hospital, Shima-shi, Japan
| | - Akira Kamei
- Gastroenterology, Ise Red Cross Hospital, Ise-shi, Japan
| |
Collapse
|
3
|
Kobara H, Tada N, Fujihara S, Nishiyama N, Masaki T. Clinical and technical outcomes of endoscopic closure of postendoscopic submucosal dissection defects: Literature review over one decade. Dig Endosc 2023; 35:216-231. [PMID: 35778927 DOI: 10.1111/den.14397] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 06/30/2022] [Indexed: 01/24/2023]
Abstract
Endoscopic submucosal dissection (ESD), which enables curative en bloc resection of early gastrointestinal neoplasms, has been an attractive minimally invasive surgery during the past two decades. Large post-ESD defects must be carefully managed to prevent adverse events (AEs). The major AEs comprise delayed bleeding (DB) and delayed perforation (DP), and overall AEs comprise DB plus DP. This review aimed to clarify the clinical efficacy and technical outcomes of endoscopic prophylactic closure for post-ESD defects. We identified studies involving ≥10 patients up to March 2022 in which endoscopic closure was applied for gastric, duodenal, and colorectal post-ESD defects. In the stomach, total rates of overall AEs and DB were significantly lower in the closure than non-closure group. In the duodenum, total rates of overall AEs, DB, and DP were significantly lower in the closure group. In the colorectum, total rates of overall AEs and DB were significantly lower in the closure group. Closure techniques, categorized into three groups (clip-based techniques, mechanical clipping, and surgical stitch-based techniques), were illustrated. Endoscopic closure demonstrated a certain ability to reduce DB after gastric, duodenal, and colorectal ESD as well as DP after duodenal ESD. Considering closure-associated costs, the indications and limitations of closure techniques should be further investigated.
Collapse
Affiliation(s)
- Hideki Kobara
- Departments of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Naoya Tada
- Departments of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Shintaro Fujihara
- Departments of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Noriko Nishiyama
- Departments of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
| | - Tsutomu Masaki
- Departments of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
| |
Collapse
|
4
|
A Metal Detector for Clip Location Tracking of Stomach and Colon Cancer during Laparoscopic Surgery. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12147330] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In laparoscopic surgery for colorectal and gastric cancer, it is difficult to locate the tumor in the cavity for excision. Tumors in the colon or stomach are blocked by mucous membranes; thus, the view from the cavity is obscured. Therefore, to determine the location of the tumor, a marker can be installed around the tumor and the location of the tumor can be found using a sensor. Until now, most of the clip-detectors that have been developed can detect the location of tumors for either colorectal or gastric cancer. The research on the development of a detector that can detect the location of tumors for both colorectal and gastric cancer, is insufficient. Most detectors for tumor location determination are devised using a magnet by connecting a wire to a clip. In this method, the position of the magnet moves along the length of the wire. Therefore, it is difficult for the detector to detect the exact location of the tumor. Based on this method, this study designs a clip maker to determine the location of a tumor and a detector that can detect the clip. The clip and the sensing element are directly connected. The clip is developed using ferrite and coil to generate a magnetic field induced by an eddy current in the metal (clip), and the detector is designed using the Colpitts oscillator to induce a magnetic field. After installing the prepared clip at the tumor location, the detector is used to detect the clip, and accordingly, the location of the tumor can be identified using the detector. To test the performance of the clip and detector, we conducted animal experiments. In the course of the animal experiment, four clips were installed in the colon and stomach, and we succeeded in detecting all the clips. Because the clip-detector is used to locate the tumor during laparoscopic surgery, an endoscope must be used. Therefore, it is predicted that the demand for laparoscopic surgery and endoscopic medical industry will increase because of the clip-detector.
Collapse
|
5
|
Yoon K, Kim KG, Chung JW, Lee WS. Clip-Detector Using a Neodymium Magnet to Locate Malignant Tumors during Laparoscopic Surgery. SENSORS (BASEL, SWITZERLAND) 2022; 22:5404. [PMID: 35891084 PMCID: PMC9319524 DOI: 10.3390/s22145404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 07/08/2022] [Accepted: 07/15/2022] [Indexed: 06/15/2023]
Abstract
During laparoscopic surgery for colorectal or gastric cancers, locating the tumor for excision is difficult owing to it being obscured by mucous membranes. Therefore, a clip can be installed around the tumor, which can be located using a sensor. Most of the clip-detectors developed thus far can only detect tumors in either the colon or stomach and require a wire to connect the clip and detector. This study designs a clip and detector that can locate a tumor in the stomach and colon. The clip contains a neodymium magnet that generates a magnetic field, and the detector includes a Colpitts oscillator that allows magnetic coupling of the clip and detector. After installing the prepared clip at the tumor location, the detector is used to locate the clip. To test the clip and detector, we conducted animal experiments, during which four clips were installed in the colon and stomach of a mini pig. We succeeded in locating the clips within 2.17 and 3.14 s in the stomach and colon, respectively, which were shorter than the detection times reported in previous studies. The demand for laparoscopic surgery and endoscopes is predicted to increase owing to this method.
Collapse
Affiliation(s)
- Kicheol Yoon
- Medical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Korea;
- Department of Biomedical Engineering, College of Medicine, Gachon University, Incheon 21565, Korea
| | - Kwang Gi Kim
- Medical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Korea;
- Department of Biomedical Engineering, College of Medicine, Gachon University, Incheon 21565, Korea
- Department of Biomedical Engineering, College of Health Science, Gachon University, Incheon 21936, Korea
- Department of Health Sciences and Technology, Gachon Advanced Institute for Health Sciences and Technology (GAIHST), Gachon University, Incheon 21565, Korea
| | - Jun-Won Chung
- Department of Gastroenterology, Gachon University Gil Medical Center & College of Medicine, Gachon University, Incheon 21565, Korea
- CAIMI Co., Ltd., #206 Building of Incheon Startup Park, 204 Convensia-daero (Songdo-dong), Yeonsu-gu, Incheon 22004, Korea
| | - Won Suk Lee
- Department of Surgery, Gachon University Gil Medical Center & College of Medicine, Gachon University, Incheon 21565, Korea;
| |
Collapse
|
6
|
Endoscopic Delivery of Polymers Reduces Delayed Bleeding after Gastric Endoscopic Submucosal Dissection: A Systematic Review and Meta-Analysis. Polymers (Basel) 2022; 14:polym14122387. [PMID: 35745963 PMCID: PMC9227627 DOI: 10.3390/polym14122387] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 05/20/2022] [Accepted: 06/09/2022] [Indexed: 01/27/2023] Open
Abstract
New endoscopic approaches for the prevention of delayed bleeding (DB) after gastric endoscopic submucosal dissection (ESD) have been reported in recent years, and endoscopic delivery of biodegradable polymers for iatrogenic ulcer hemostasis and coverage has emerged as one of the most promising techniques for post-ESD management. However, the comparative efficacy of these techniques remains uncertain. We performed a systematic search of multiple databases up to May 2022 to identify studies reporting DB rates as outcomes in patients undergoing gastric ESD who were treated with subsequent endoscopic management, including endoscopic closure (clip-based methods and suturing), PGA sheet tissue shielding, and hemostatic powder/gel spray (including polymeric sealants and other adhesives). The risk ratios (RRs) of delayed bleeding in treatment groups and control groups were pooled, and the Bayesian framework was used to perform a network meta-analysis (NMA). Among these studies, 16 head-to-head comparisons that covered 2742 lesions were included in the NMA. Tissue shielding using PGA sheets significantly reduced the risk of DB by nearly two thirds in high-risk patients, while hemostatic spray systems, primarily polymer-based, reduced DB in low-risk patients nine-fold. Researchers should recognize the essential role of polymers in the management of ESD-induced ulcers, and develop and validate clinical application strategies for promising materials.
Collapse
|