1
|
Liu T, Ma G, Xu W, Liang R, Wei H, Liu X. Morphometric Assessment of Sclera and Ciliary Body in Patients with Noninfectious Anterior Scleritis: A Quantitative Study Using Ultrasound Biomicroscopy. Ocul Immunol Inflamm 2024; 32:2000-2007. [PMID: 38376887 DOI: 10.1080/09273948.2024.2315189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/24/2024] [Accepted: 01/31/2024] [Indexed: 02/21/2024]
Abstract
BACKGROUND At present, the severity and grade of anterior scleritis are judged mainly based on the area and location of involvement, whether there is necrosis, etc. Quantitative measurement of sclera and surrounding tissues will help to accurately assess the severity of scleritis and provide quantitative indicators for the choice of treatment. METHODS We retrospectively analyzed the thickness of sclera and ciliary bodies detected by ultrasound biological microscopy (UBM) in noninfectious anterior scleritis patients who subsequently were treated with topical or systemic treatment, and visited our hospital from March 2014 to March 2021. Age- and sex-matched normal individuals were used as controls. RESULTS A total of 185 patients (50 males and 135 females) with noninfectious anterior scleritis and 84 (31 males and 53 females) controls were included. In patients with noninfectious scleritis, the thickness of sclera and the ciliary body were significantly greater than those in the control group (p < 0.05). Before treatment, the thickness of sclera and the ciliary body in systemic treatment group was significantly higher than that in topical treatment group (p < 0.05). After treatment, both thicknesses of sclera and the ciliary body decreased significantly (p < 0.05). The ratio of ciliary body thickness from the site of inflammation to the normal position was significantly higher in the systemic treatment group than in the topical treatment group. CONCLUSIONS UBM quantitatively shows a decrease in AST/CBT in patients with anterior scleritis after treatment. The ratio of ciliary body thickness at the site of information to that at the normal position may be a reference for the choice of treatment.
Collapse
Affiliation(s)
- Tao Liu
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
- Department of Ophthalmology, Linyi Central Hospital, Linyi, Shandong, People's Republic of China
| | - Guanshen Ma
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
| | - Wenjing Xu
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
| | - Ruyu Liang
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
| | - Haihui Wei
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
| | - Xiaoli Liu
- Ophthalmologic Center of the Second Hospital, Jilin University, Changchun, People's Republic of China
| |
Collapse
|
2
|
Wang Q, Chen X, Li L, Zhou L, Gao Y, Shen L, Peng S, Zhou Q. Effect of anterior segment structure on vault and position after implantable collamer lens implantation. Indian J Ophthalmol 2024; 72:1298-1303. [PMID: 38767559 PMCID: PMC11552803 DOI: 10.4103/ijo.ijo_2663_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/29/2024] [Accepted: 04/01/2024] [Indexed: 05/22/2024] Open
Abstract
PURPOSE To evaluate the effect of anterior-segment structure on vault and position after implantable collamer lens (ICL) implantation using ultrasound biomicroscopy. METHODS The retrospective case-control study included insufficient vault eyes (<250 µm), ideal vault eyes (250-750 µm), and excessive vault eyes (>750 µm). The preoperative biometric parameters of the anterior-segment structure and basic data between the three groups were analyzed using one-way analysis of variance. RESULTS There were significant differences ( P < 0.05) between the three groups in maximum ciliary body thickness (CBT max ), iris-zonule distance (IZD), and trabecular-ciliary angle (TCA). The vault gradually decreased as CBT max decreased and TCA increased. In the pairwise comparison, the CBT max comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.024, 95% CI: -0.17-0.017 µm); the TCA comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.005, 95% CI: 1.78°-12.15°); The IZD comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.037, 95% CI: 0.0027-0.1119 µm). The analysis of 284 ICL haptics locations showed that there were 16.67%, 32.69%, and 70.83% haptics located in the ciliary sulcus in three groups, respectively. CONCLUSION The vault and ICL haptics position are related to anterior-segment structure. A thinner and posteriorly positioned ciliary body would increase the risk of low vault and fewer ICL haptics located in the ciliary sulcus after ICL implantation. This provides guidance for the selection of the ICL size and placement position before surgery.
Collapse
Affiliation(s)
- Qin Wang
- Department of Refractive Surgery and Fundus Diseases, Aier Eye Hospital of Anhui Medical University, No.198, Wangjiang West Road, Shushan District, Hefei, 230031, Anhui, PR China
| | - Xiao Chen
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| | - Li Li
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| | - Lin Zhou
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| | - Yang Gao
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| | - Li Shen
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| | - Shaomin Peng
- Department of Refractive Surgery and Fundus Diseases, Aier Eye Hospital of Anhui Medical University, No.198, Wangjiang West Road, Shushan District, Hefei, 230031, Anhui, PR China
| | - Qizhi Zhou
- Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China
| |
Collapse
|
3
|
Davies LN, Biswas S, Bullimore M, Cruickshank F, Estevez JJ, Khanal S, Kollbaum P, Marcotte-Collard R, Montani G, Plainis S, Richdale K, Simard P, Wolffsohn JS. BCLA CLEAR presbyopia: Mechanism and optics. Cont Lens Anterior Eye 2024; 47:102185. [PMID: 38796331 DOI: 10.1016/j.clae.2024.102185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2024]
Abstract
With over a billion adults worldwide currently affected, presbyopia remains a ubiquitous, global problem. Despite over a century of study, the precise mechanism of ocular accommodation and presbyopia progression remains a topic of debate. Accordingly, this narrative review outlines the lenticular and extralenticular components of accommodation together with the impact of age on the accommodative apparatus, neural control of accommodation, models of accommodation, the impact of presbyopia on retinal image quality, and both historic and contemporary theories of presbyopia.
Collapse
Affiliation(s)
- Leon N Davies
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK.
| | - Sayantan Biswas
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK
| | | | - Fiona Cruickshank
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK
| | - Jose J Estevez
- Caring Futures Institute, College of Nursing and Health Sciences, Optometry and Vision Science, Flinders University, Adelaide, Australia; Flinders Centre for Ophthalmology, Eye and Vision Research, Department of Ophthalmology, Flinders University, Adelaide, Australia
| | - Safal Khanal
- Department of Optometry and Vision Science, The University of Alabama at Birmingham, USA
| | | | | | | | - Sotiris Plainis
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK; Laboratory of Optics and Vision, School of Medicine, University of Crete, Greece
| | | | - Patrick Simard
- School of Optometry, Universite de Montreal, Montreal, Quebec, Canada
| | - James S Wolffsohn
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK
| |
Collapse
|
4
|
Chang W, Niu L, Zhou X, Wang X, Yu Z, Qian Y. Risk factors associated with haptic malposition in eyes implanted with implantable collamer lenses. J Cataract Refract Surg 2024; 50:276-282. [PMID: 38031330 PMCID: PMC10878456 DOI: 10.1097/j.jcrs.0000000000001368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/09/2023] [Accepted: 11/11/2023] [Indexed: 12/01/2023]
Abstract
PURPOSE To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). SETTING Eye and ENT Hospital, Fudan University, Shanghai, China. DESIGN Prospective nonrandomized observational study. METHODS This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. RESULTS ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris-ciliary process distance (ICPD, P < .001), and ciliary process length ( P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris-ciliary angle ( P = .006), CBTmax ( P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size ( P = .015) were significantly associated with IRH. Spherical equivalents ( P = .042), STSL ( P = .001), and ICS count ( P = .020) significantly correlated with the central vault. CONCLUSIONS Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.
Collapse
Affiliation(s)
- Weiteng Chang
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Lingling Niu
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Xingtao Zhou
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Xiaoying Wang
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Zhiqiang Yu
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| | - Yishan Qian
- From the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Yiming Y, Xi C, Huan Y, Liming C, Na Y, Pei C, Ying Y, Yan L, Keming Y. Evaluation of ciliary body morphology and position of the implantable collamer lens in low-vault eyes using ultrasound biomicroscopy. J Cataract Refract Surg 2023; 49:1133-1139. [PMID: 37586102 DOI: 10.1097/j.jcrs.0000000000001285] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 08/06/2023] [Indexed: 08/18/2023]
Abstract
PURPOSE To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault. SETTING Zhongshan Ophthalmic Center, Guangzhou, China. DESIGN Retrospective case-control observational study. METHODS In this study, 73 eyes of 73 patients with an insufficient vault (<250 μm) were matched with 73 eyes with an ideal vault (250 to 750 μm). Ultrasound biomicroscopy was used to determine the ciliary body morphology and ICL position. The biometric parameters acquired by Scheimpflug tomography were compared. The correlation between the vault and these factors was analyzed, and the least absolute shrinkage and selection operator method was used to screen the risk factors for low vault. RESULTS The low-vault group had a steeper corneal curvature, thicker lens thickness (LT), higher crystalline lens rise, and shorter axial length (AL) (all P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular-ciliary angle (TCA), iris-ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault. CONCLUSIONS Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.
Collapse
Affiliation(s)
- Ye Yiming
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Kilic D, Förster A, Mertens E, Dick HB, Taneri S. Rotational Stability After Implantation of Two Different Phakic Toric Intraocular Lenses. J Refract Surg 2023; 39:463-472. [PMID: 37449509 DOI: 10.3928/1081597x-20230512-03] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
PURPOSE To compare clinical outcomes and rotational stability of the toric implantable Collamer lens (TICL) and toric implantable phakic contact lens (TIPCL). METHODS Charts were reviewed from January 2011 to January 2023 to identify all TICLs and TIPCLs implanted by a single surgeon. Implant size was generally chosen according to the manufacturer's recommendation, but 15 TIPCLs 0.25 mm larger than recommended to increase vaulting were included. RESULTS Eighty-four TICLs and 98 TIPCLs were identified and yielded excellent refractive and visual results in eyes with high myopic astigmatism at the last follow-up visit. No case of acute glaucoma or cataract induction was observed. In total, 15 (8.2%) rotated lenses were recorded; 2 (2.4%) TICLs and 13 (13.3%) TIPCLs (P = .013). Eyes in both groups were similar in preoperative spherical equivalent, cylinder, white-to-white distance, anterior chamber depth (ACD), anterior chamber angle, and mean follow-up times (P = .925, .673, .822, .794, .358, and .873, respectively). Average TICL size was larger than TIPCL size (P < .001). Rotation of the lenses was positively correlated with cylinder and negatively correlated with ACD but not with vaulting (P = .001, r = 0.253; P = .011, r = -0.193; P = .488, r = -0.057; respectively). Vaulting was positively correlated with preoperative ACD (P ≤ .001, r = .329). In eyes with a rotated TIPCL, preoperative cylinder was higher and ACD was shallower than in eyes with a stable TIPCL (P = .001 and .007, respectively). Increasing the implant size had no significant effect on rotation rate (P = .685). CONCLUSIONS Although both implants were safe and effective in highly myopic eyes, TICL rotated less frequently than TIPCL and required fewer secondary interventions. Rotation was correlated with preoperative cylinder and ACD but not lens vaulting. [J Refract Surg. 2023;39(7):463-472.].
Collapse
|
7
|
Ferrara M, Zheng Y, Romano V. Editorial: Imaging in Ophthalmology. J Clin Med 2022; 11:jcm11185433. [PMID: 36143079 PMCID: PMC9503085 DOI: 10.3390/jcm11185433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 09/13/2022] [Indexed: 11/16/2022] Open
Abstract
Over the last decade, ophthalmology has significantly benefited from advances in vivo non-invasive ophthalmic imaging techniques that play currently a fundamental role in the clinical assessment, diagnosis, management, and monitoring of a wide variety of conditions involving both the anterior and posterior segment [...]
Collapse
Affiliation(s)
| | - Yalin Zheng
- Department of Eye and Vision Science, University of Liverpool, Liverpool L69 3BX, UK
- St Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L69 3BX, UK
| | - Vito Romano
- Eye Clinic, Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, 25121 Brescia, Italy
- ASST Civil Hospital of Brescia, 25123 Brescia, Italy
- Correspondence:
| |
Collapse
|