1
|
Freund BE, Sherman WJ, Sabsevitz DS, Middlebrooks EH, Feyissa AM, Garcia DM, Grewal SS, Chaichana KL, Quinones-Hinojosa A, Tatum WO. Can we improve electrocorticography using a circular grid array in brain tumor surgery? Biomed Phys Eng Express 2023; 9:065027. [PMID: 37871586 DOI: 10.1088/2057-1976/ad05dd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 10/23/2023] [Indexed: 10/25/2023]
Abstract
Intraoperative electrocorticography (iECoG) is used as an adjunct to localize the epileptogenic zone during surgical resection of brain tumors in patients with focal epilepsies. It also enables monitoring of after-discharges and seizures with EEG during functional brain mapping with electrical stimulation. When seizures or after-discharges are present, they complicate accurate interpretation of the mapping strategy to outline the brain's eloquent function and can affect the surgical procedure. Recurrent seizures during surgery requires urgent treatment and, when occurring during awake craniotomy, often leads to premature termination of brain mapping due to post-ictal confusion or sedation from acute rescue therapy. There are mixed results in studies on efficacy with iECoG in patients with epilepsy and brain tumors influencing survival and functional outcomes following surgery. Commercially available electrode arrays have inherent limitations. These could be improved with customization potentially leading to greater precision in safe and maximal resection of brain tumors. Few studies have assessed customized electrode grid designs as an alternative to commercially available products. Higher density electrode grids with intercontact distances less than 1 cm improve spatial delineation of electrophysiologic sources, including epileptiform activity, electrographic seizures, and afterdischarges on iECoG during functional brain mapping. In response to the shortcomings of current iECoG grid technologies, we designed and developed a novel higher-density hollow circular electrode grid array. The 360-degree iECoG monitoring capability allows continuous EEG recording during surgical intervention through the aperture with and without electrical stimulation mapping. Compared with linear strip electrodes that are commonly used for iECoG during surgery, the circular grid demonstrates significant benefits in brain tumor surgery. This includes quicker recovery of post-operative motor deficits (2.4 days versus 9 days, p = 0.05), more extensive tumor resection (92.0% versus 77.6%, p = 0.003), lesser reduction in Karnofsky Performance scale postoperatively (-2 versus -11.6, p = 0.007), and more sensitivity to recording afterdischarges. In this narrative review, we discuss the advantages and disadvantages of commercially available recording devices in the operating room and focus on the usefulness of the higher-density circular grid.
Collapse
Affiliation(s)
- Brin E Freund
- Department of Neurology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Wendy J Sherman
- Department of Neurology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - David S Sabsevitz
- Department of Psychiatry, Division of Neuropsychology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Erik H Middlebrooks
- Department of Radiology, Division of Neuroradiology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
- Department of Neurosurgery, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Anteneh M Feyissa
- Department of Neurology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Diogo Moniz Garcia
- Department of Neurosurgery, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Sanjeet S Grewal
- Department of Neurosurgery, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Kaisorn L Chaichana
- Department of Neurosurgery, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - Alfredo Quinones-Hinojosa
- Department of Neurosurgery, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| | - William O Tatum
- Department of Neurology, Mayo Clinic College of Medicine, Mayo Clinic, Jacksonville, FL, United States of America
| |
Collapse
|
2
|
Implementation of an In-House 3D Manufacturing Unit in a Public Hospital’s Radiology Department. Healthcare (Basel) 2022; 10:healthcare10091791. [PMID: 36141403 PMCID: PMC9498605 DOI: 10.3390/healthcare10091791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/30/2022] [Accepted: 09/14/2022] [Indexed: 11/23/2022] Open
Abstract
Objective: Three-dimensional printing has become a leading manufacturing technique in healthcare in recent years. Doubts in published studies regarding the methodological rigor and cost-effectiveness and stricter regulations have stopped the transfer of this technology in many healthcare organizations. The aim of this study was the evaluation and implementation of a 3D printing technology service in a radiology department. Methods: This work describes a methodology to implement a 3D printing service in a radiology department of a Spanish public hospital, considering leadership, training, workflow, clinical integration, quality processes and usability. Results: The results correspond to a 6-year period, during which we performed up to 352 cases, requested by 85 different clinicians. The training, quality control and processes required for the scaled implementation of an in-house 3D printing service are also reported. Conclusions: Despite the maturity of the technology and its impact on the clinic, it is necessary to establish new workflows to correctly implement them into the strategy of the health organization, adjusting it to the needs of clinicians and to their specific resources. Significance: This work allows hospitals to bridge the gap between research and 3D printing, setting up its transfer to clinical practice and using implementation methodology for decision support.
Collapse
|