Wong KFM, Huang W, Ee DYH, Ng EYK. Design and validation of dual-point time-differentiated photoplethysmogram (2PPG) wearable for cuffless blood pressure estimation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 253:108251. [PMID: 38824806 DOI: 10.1016/j.cmpb.2024.108251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 05/02/2024] [Accepted: 05/24/2024] [Indexed: 06/04/2024]
Abstract
BACKGROUND & OBJECTIVES Measurement of blood pressure (BP) in ambulatory patients is crucial for at high-risk cardiovascular patients. A non-obtrusive, non-occluding device that continuously measures BP via photoplethysmography will enable long-term ambulatory assessment of BP. The aim of this study is to validate the metasense 2PPG cuffless wearable design for continuous BP estimation without ECG. METHODS A customized high-speed electronic optical sensor architecture with laterally spaced reflectance pulse oximetry was designed into a simple unobtrusive low-power wearable in the form of a watch. 78 volunteers with a mean age of 32.72 ± 7.4 years (21 to 64), 51% male, 49% female were recruited with ECG-2PPG signals acquired. The fiducial features of the 2PPG morphologies were then attributed to the estimator. A 9-1 K-fold cross-validation was applied in the ML. RESULTS The correlation for PTT-SBP was 0.971 and for PTT-DBP was 0.954. The mean absolute error was 3.167±1.636 mmHg for SBP and 6.4 ± 3.9 mm Hg for DBP. The ambulatory estimate for SBP and DBP for an individual over 3 days with 8-hour recordings was 0.70-0.81 for SBP and 0.42-0.51 for DBP with a ± 2.65 mmHg for SBP and ±2.02 mmHg for DBP. For SBP, 98% of metasense measurements were within 15 mm Hg and for DBP, 91% of metasense measurements were within 10 mmHg CONCLUSIONS: The metasense device provides continuous, non-invasive BP estimations that are comparable to ambulatory BP meters. The portability and unobtrusiveness of this device, as well as the ability to continuously measure BP could one day enable long-term ambulatory BP measurement for precision cardiovascular therapeutic regimens.
Collapse
Affiliation(s)
- Kei Fong Mark Wong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore
| | | | | | - Eddie Yin Kwee Ng
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore.
| |
Collapse
|
2
|
Elgendi M, Haugg F, Fletcher RR, Allen J, Shin H, Alian A, Menon C. Recommendations for evaluating photoplethysmography-based algorithms for blood pressure assessment. COMMUNICATIONS MEDICINE 2024; 4:140. [PMID: 38997447 PMCID: PMC11245506 DOI: 10.1038/s43856-024-00555-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 06/19/2024] [Indexed: 07/14/2024] Open
Abstract
Photoplethysmography (PPG) is a non-invasive optical technique that measures changes in blood volume in the microvascular tissue bed of the body. While it shows potential as a clinical tool for blood pressure (BP) assessment and hypertension management, several sources of error can affect its performance. One such source is the PPG-based algorithm, which can lead to measurement bias and inaccuracy. Here, we review seven widely used measures to assess PPG-based algorithm performance and recommend implementing standardized error evaluation steps in their development. This standardization can reduce bias and improve the reliability and accuracy of PPG-based BP estimation, leading to better health outcomes for patients managing hypertension.
Collapse
Affiliation(s)
- Mohamed Elgendi
- Biomedical and Mobile Health Technology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland.
| | - Fridolin Haugg
- Biomedical and Mobile Health Technology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland
| | - Richard Ribon Fletcher
- Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, CV1 5FB, Coventry, UK
| | - Hangsik Shin
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Aymen Alian
- Yale School of Medicine, Yale University, New Haven, CT, 06510, USA
| | - Carlo Menon
- Biomedical and Mobile Health Technology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland
| |
Collapse
|
3
|
Speroni G, Antedoro P, Marturet S, Martino G, Chavez C, Hidalgo C, Villacorta MV, Ahrtz I, Casadei M, Fuentes N, Kremeier P, Böhm SH, Tusman G. Finger photopletysmography detects early acute blood loss in compensated blood donors: a pilot study. Physiol Meas 2024; 45:055018. [PMID: 38749458 DOI: 10.1088/1361-6579/ad4c54] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 05/15/2024] [Indexed: 05/29/2024]
Abstract
Objective.Diagnosis of incipient acute hypovolemia is challenging as vital signs are typically normal and patients remain asymptomatic at early stages. The early identification of this entity would affect patients' outcome if physicians were able to treat it precociously. Thus, the development of a noninvasive, continuous bedside monitoring tool to detect occult hypovolemia before patients become hemodynamically unstable is clinically relevant. We hypothesize that pulse oximeter's alternant (AC) and continuous (DC) components of the infrared light are sensitive to acute and small changes in patient's volemia. We aimed to test this hypothesis in a cohort of healthy blood donors as a model of slight hypovolemia.Approach.We planned to prospectively study blood donor volunteers removing 450 ml of blood in supine position. Noninvasive arterial blood pressure, heart rate, and finger pulse oximetry were recorded. Data was analyzed before donation, after donation and during blood auto-transfusion generated by the passive leg-rising (PLR) maneuver.Main results.Sixty-six volunteers (44% women) accomplished the protocol successfully. No clinical symptoms of hypovolemia, arterial hypotension (systolic pressure < 90 mmHg), brady-tachycardia (heart rate <60 and >100 beats-per-minute) or hypoxemia (SpO2< 90%) were observed during donation. The AC signal before donation (median 0.21 and interquartile range 0.17 a.u.) increased after donation [0.26(0.19) a.u;p< 0.001]. The DC signal before donation [94.05(3.63) a.u] increased after blood extraction [94.65(3.49) a.u;p< 0.001]. When the legs' blood was auto-transfused during the PLR, the AC [0.21(0.13) a.u.;p= 0.54] and the DC [94.25(3.94) a.u.;p= 0.19] returned to pre-donation levels.Significance.The AC and DC components of finger pulse oximetry changed during blood donation in asymptomatic volunteers. The continuous monitoring of these signals could be helpful in detecting occult acute hypovolemia. New pulse oximeters should be developed combining the AC/DC signals with a functional hemodynamic monitoring of fluid responsiveness to define which patient needs fluid administration.
Collapse
Affiliation(s)
- Gerardo Speroni
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Patricia Antedoro
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Silvia Marturet
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Gabriela Martino
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Celia Chavez
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Cristian Hidalgo
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - María V Villacorta
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Ivo Ahrtz
- Department of Hemotherapy, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Manuel Casadei
- School of Engineering, Universidad Nacional de Mar del Plata, Mar del Plata, Buenos Aires, Argentina
| | - Nora Fuentes
- Department of Intensive Care Medicine, Hospital Privadode Comunidad, Mar del Plata, Buenos Aires, Argentina
| | - Peter Kremeier
- Simulation Center for Mechanical Ventilation, Karlsruhe, Germany
| | - Stephan H Böhm
- Clinic of Anesthesiology, Intensive Care Medicine and Pain Therapy, Rostock University Medical Center, Rostock, Germany
| | - Gerardo Tusman
- Department of Anesthesiology, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires, Argentina
| |
Collapse
|
4
|
Slapničar G, Wang W, Luštrek M. Generalized channel separation algorithms for accurate camera-based multi-wavelength PTT and BP estimation. BIOMEDICAL OPTICS EXPRESS 2024; 15:3128-3146. [PMID: 38855660 PMCID: PMC11161386 DOI: 10.1364/boe.518562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/19/2024] [Accepted: 03/22/2024] [Indexed: 06/11/2024]
Abstract
Single-site multi-wavelength (MW) pulse transit time (PTT) measurement was recently proposed using contact sensors with sequential illumination. It leverages different penetration depths of light to measure the traversal of a cardiac pulse between skin layers. This enabled continuous single-site MW blood pressure (BP) monitoring, but faces challenges like subtle skin compression, which importantly influences the PPG morphology and subsequent PTT. We extended this idea to contact-free camera-based sensing and identified the major challenge of color channel overlap, which causes the signals obtained from a consumer RGB camera to be a mixture of responses in different wavelengths, thus not allowing for meaningful PTT measurement. To address this, we propose novel camera-independent data-driven channel separation algorithms based on constrained genetic algorithms. We systematically validated the algorithms on camera recordings of palms and corresponding ground-truth BP measurements of 13 subjects in two different scenarios, rest and activity. We compared the proposed algorithms against established blind source separation methods and against previous camera-specific physics-based method, showing good performance in both PTT reconstruction and BP estimation using a Random Forest regressor. The best-performing algorithm achieved mean absolute errors (MAEs) of 3.48 and 2.61 mmHg for systolic and diastolic BP in a leave-one-subject-out experiment with personalization, solidifying the proposed algorithms as enablers of novel contact-free MW PTT and BP estimation.
Collapse
Affiliation(s)
- Gašper Slapničar
- Department of Intelligent Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
- Jožef Stefan International Postgraduate School, Jamova cesta 39, 1000 Ljubljana, Slovenia
| | - Wenjin Wang
- Biomedical Engineering Department, Southern University of Science and Technology, 1088 Xueyuan Blvd, Nanshan, Shenzhen, Guangdong, China
| | - Mitja Luštrek
- Department of Intelligent Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
- Jožef Stefan International Postgraduate School, Jamova cesta 39, 1000 Ljubljana, Slovenia
| |
Collapse
|
5
|
Dong S, Wang Q, Wang S, Zhou C, Wang H. Hypotension prediction index for the prevention of hypotension during surgery and critical care: A narrative review. Comput Biol Med 2024; 170:107995. [PMID: 38325215 DOI: 10.1016/j.compbiomed.2024.107995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/17/2023] [Accepted: 01/13/2024] [Indexed: 02/09/2024]
Abstract
Surgeons and anesthesia clinicians commonly face a hemodynamic disturbance known as intraoperative hypotension (IOH), which has been linked to more severe postoperative outcomes and increases mortality rates. Increased occurrence of IOH has been positively associated with mortality and incidence of myocardial infarction, stroke, and organ dysfunction hypertension. Hence, early detection and recognition of IOH is meaningful for perioperative management. Currently, when hypotension occurs, clinicians use vasopressor or fluid therapy to intervene as IOH develops but interventions should be taken before hypotension occurs; therefore, the Hypotension Prediction Index (HPI) method can be used to help clinicians further react to the IOH process. This literature review evaluates the HPI method, which can reliably predict hypotension several minutes before a hypotensive event and is beneficial for patients' outcomes.
Collapse
Affiliation(s)
- Siwen Dong
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China
| | - Qing Wang
- Department of Anesthesiology, Tongde Hospital of Zhejiang Province, Hangzhou 310012, China
| | - Shuai Wang
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China
| | - Congcong Zhou
- Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China; Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China
| | - Hongwei Wang
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China; Department of Anesthesiology, Tongde Hospital of Zhejiang Province, Hangzhou 310012, China.
| |
Collapse
|
6
|
Ferizoli R, Karimpour P, May JM, Kyriacou PA. Arterial stiffness assessment using PPG feature extraction and significance testing in an in vitro cardiovascular system. Sci Rep 2024; 14:2024. [PMID: 38263412 PMCID: PMC10806047 DOI: 10.1038/s41598-024-51395-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/04/2024] [Indexed: 01/25/2024] Open
Abstract
Cardiovascular diseases (CVDs) remain the leading cause of global mortality, therefore understanding arterial stiffness is essential to developing innovative technologies to detect, monitor and treat them. The ubiquitous spread of photoplethysmography (PPG), a completely non-invasive blood-volume sensing technology suitable for all ages, highlights immense potential for arterial stiffness assessment in the wider healthcare setting outside specialist clinics, for example during routine visits to a General Practitioner or even at home with the use of mobile and wearable health devices. This study employs a custom-manufactured in vitro cardiovascular system with vessels of varying stiffness to test the hypothesis that PPG signals may be used to detect and assess the level of arterial stiffness under controlled conditions. Analysis of various morphological features demonstrated significant (p < 0.05) correlations with vessel stiffness. Particularly, area related features were closely linked to stiffness in red PPG signals, while for infrared PPG signals the most correlated features were related to pulse-width. This study demonstrates the utility of custom vessels and in vitro investigations to work towards non-invasive cardiovascular assessment using PPG, a valuable tool with applications in clinical healthcare, wearable health devices and beyond.
Collapse
Affiliation(s)
- Redjan Ferizoli
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK.
| | - Parmis Karimpour
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| | - James M May
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| | - Panicos A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| |
Collapse
|
7
|
Plain B, Pielage H, Kramer SE, Richter M, Saunders GH, Versfeld NJ, Zekveld AA, Bhuiyan TA. Combining Cardiovascular and Pupil Features Using k-Nearest Neighbor Classifiers to Assess Task Demand, Social Context, and Sentence Accuracy During Listening. Trends Hear 2024; 28:23312165241232551. [PMID: 38549351 PMCID: PMC10981225 DOI: 10.1177/23312165241232551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 01/04/2024] [Accepted: 01/25/2024] [Indexed: 04/01/2024] Open
Abstract
In daily life, both acoustic factors and social context can affect listening effort investment. In laboratory settings, information about listening effort has been deduced from pupil and cardiovascular responses independently. The extent to which these measures can jointly predict listening-related factors is unknown. Here we combined pupil and cardiovascular features to predict acoustic and contextual aspects of speech perception. Data were collected from 29 adults (mean = 64.6 years, SD = 9.2) with hearing loss. Participants performed a speech perception task at two individualized signal-to-noise ratios (corresponding to 50% and 80% of sentences correct) and in two social contexts (the presence and absence of two observers). Seven features were extracted per trial: baseline pupil size, peak pupil dilation, mean pupil dilation, interbeat interval, blood volume pulse amplitude, pre-ejection period and pulse arrival time. These features were used to train k-nearest neighbor classifiers to predict task demand, social context and sentence accuracy. The k-fold cross validation on the group-level data revealed above-chance classification accuracies: task demand, 64.4%; social context, 78.3%; and sentence accuracy, 55.1%. However, classification accuracies diminished when the classifiers were trained and tested on data from different participants. Individually trained classifiers (one per participant) performed better than group-level classifiers: 71.7% (SD = 10.2) for task demand, 88.0% (SD = 7.5) for social context, and 60.0% (SD = 13.1) for sentence accuracy. We demonstrated that classifiers trained on group-level physiological data to predict aspects of speech perception generalized poorly to novel participants. Individually calibrated classifiers hold more promise for future applications.
Collapse
Affiliation(s)
- Bethany Plain
- Otolaryngology Head and Neck Surgery, Ear & Hearing, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands
- Eriksholm Research Centre, Snekkersten, Denmark
| | - Hidde Pielage
- Otolaryngology Head and Neck Surgery, Ear & Hearing, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands
- Eriksholm Research Centre, Snekkersten, Denmark
| | - Sophia E. Kramer
- Otolaryngology Head and Neck Surgery, Ear & Hearing, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands
| | - Michael Richter
- School of Psychology, Liverpool John Moores University, Liverpool, UK
| | - Gabrielle H. Saunders
- Manchester Centre for Audiology and Deafness (ManCAD), University of Manchester, Manchester, UK
| | - Niek J. Versfeld
- Otolaryngology Head and Neck Surgery, Ear & Hearing, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands
| | - Adriana A. Zekveld
- Otolaryngology Head and Neck Surgery, Ear & Hearing, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands
| | | |
Collapse
|
8
|
Evdochim L, Chiriac E, Avram M, Dobrescu L, Dobrescu D, Stanciu S, Halichidis S. Red Blood Cells' Area Deformation as the Origin of the Photoplethysmography Signal. SENSORS (BASEL, SWITZERLAND) 2023; 23:9515. [PMID: 38067889 PMCID: PMC10708758 DOI: 10.3390/s23239515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/22/2023] [Accepted: 11/28/2023] [Indexed: 12/18/2023]
Abstract
The origin of the photoplethysmography (PPG) signal is a debatable topic, despite plausible models being addressed. One concern revolves around the correlation between the mechanical waveform's pulsatile nature and the associated biomechanism. The interface between these domains requires a clear mathematical or physical model that can explain physiological behavior. Describing the correct origin of the recorded optical waveform not only benefits the development of the next generation of biosensors but also defines novel health markers. In this study, the assumption of a pulsatile nature is based on the mechanism of blood microcirculation. At this level, two interconnected phenomena occur: variation in blood flow velocity through the capillary network and red blood cell (RBC) shape deformation. The latter effect was qualitatively investigated in synthetic capillaries to assess the experimental data needed for PPG model development. Erythrocytes passed through 10 µm and 6 µm microchannel widths with imposed velocities between 50 µm/s and 2000 µm/s, according to real scenarios. As a result, the length and area deformation of RBCs followed a logarithmic law function of the achieved traveling speeds. Applying radiometric expertise on top, mechanical-optical insights are obtained regarding PPG's pulsatile nature. The mathematical equations derived from experimental data correlate microcirculation physiologic with waveform behavior at a high confidence level. The transfer function between the biomechanics and the optical signal is primarily influenced by the vasomotor state, capillary network orientation, concentration, and deformation performance of erythrocytes.
Collapse
Affiliation(s)
- Lucian Evdochim
- Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania; (L.D.); (D.D.)
| | - Eugen Chiriac
- National Institute for Research and Development in Microtechnologies—IMT Bucharest, 077190 Voluntari, Romania; (E.C.); (M.A.)
| | - Marioara Avram
- National Institute for Research and Development in Microtechnologies—IMT Bucharest, 077190 Voluntari, Romania; (E.C.); (M.A.)
| | - Lidia Dobrescu
- Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania; (L.D.); (D.D.)
| | - Dragoș Dobrescu
- Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania; (L.D.); (D.D.)
| | - Silviu Stanciu
- Laboratory of Cardiovascular Noninvasive Investigations, Dr. Carol Davila Central Military Emergency University Hospital, 010242 Bucharest, Romania;
| | - Stela Halichidis
- Department of Clinical Medical Disciplines, Faculty of Medicine, Ovidius University of Constanta, 900527 Constanta, Romania;
| |
Collapse
|
9
|
Yogev D, Goldberg T, Arami A, Tejman-Yarden S, Winkler TE, Maoz BM. Current state of the art and future directions for implantable sensors in medical technology: Clinical needs and engineering challenges. APL Bioeng 2023; 7:031506. [PMID: 37781727 PMCID: PMC10539032 DOI: 10.1063/5.0152290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 08/28/2023] [Indexed: 10/03/2023] Open
Abstract
Implantable sensors have revolutionized the way we monitor biophysical and biochemical parameters by enabling real-time closed-loop intervention or therapy. These technologies align with the new era of healthcare known as healthcare 5.0, which encompasses smart disease control and detection, virtual care, intelligent health management, smart monitoring, and decision-making. This review explores the diverse biomedical applications of implantable temperature, mechanical, electrophysiological, optical, and electrochemical sensors. We delve into the engineering principles that serve as the foundation for their development. We also address the challenges faced by researchers and designers in bridging the gap between implantable sensor research and their clinical adoption by emphasizing the importance of careful consideration of clinical requirements and engineering challenges. We highlight the need for future research to explore issues such as long-term performance, biocompatibility, and power sources, as well as the potential for implantable sensors to transform healthcare across multiple disciplines. It is evident that implantable sensors have immense potential in the field of medical technology. However, the gap between research and clinical adoption remains wide, and there are still major obstacles to overcome before they can become a widely adopted part of medical practice.
Collapse
Affiliation(s)
| | | | | | | | | | - Ben M. Maoz
- Authors to whom correspondence should be addressed: and
| |
Collapse
|
10
|
Baciu VE, Lambert Cause J, Solé Morillo Á, García-Naranjo JC, Stiens J, da Silva B. Anomaly Detection in Multi-Wavelength Photoplethysmography Using Lightweight Machine Learning Algorithms. SENSORS (BASEL, SWITZERLAND) 2023; 23:6947. [PMID: 37571730 PMCID: PMC10422657 DOI: 10.3390/s23156947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/18/2023] [Accepted: 08/01/2023] [Indexed: 08/13/2023]
Abstract
Over the past few years, there has been increased interest in photoplethysmography (PPG) technology, which has revealed that, in addition to heart rate and oxygen saturation, the pulse shape of the PPG signal contains much more valuable information. Lately, the wearable market has shifted towards a multi-wavelength and multichannel approach to increase signal robustness and facilitate the extraction of other intrinsic information from the signal. This transition presents several challenges related to complexity, accuracy, and reliability of algorithms. To address these challenges, anomaly detection stages can be employed to increase the accuracy and reliability of estimated parameters. Powerful algorithms, such as lightweight machine learning (ML) algorithms, can be used for anomaly detection in multi-wavelength PPG (MW-PPG). The main contributions of this paper are (a) proposing a set of features with high information gain for anomaly detection in MW-PPG signals in the classification context, (b) assessing the impact of window size and evaluating various lightweight ML models to achieve highly accurate anomaly detection, and (c) examining the effectiveness of MW-PPG signals in detecting artifacts.
Collapse
Affiliation(s)
- Vlad-Eusebiu Baciu
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (J.L.C.); (Á.S.M.); (J.S.)
| | - Joan Lambert Cause
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (J.L.C.); (Á.S.M.); (J.S.)
- Department of Biomedical Engineering, Universidad de Oriente, Santiago de Cuba 90500, Cuba
| | - Ángel Solé Morillo
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (J.L.C.); (Á.S.M.); (J.S.)
| | | | - Johan Stiens
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (J.L.C.); (Á.S.M.); (J.S.)
| | - Bruno da Silva
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (J.L.C.); (Á.S.M.); (J.S.)
| |
Collapse
|
11
|
Lee Y, Seo J, Park J, Lee H. Analysis for calibration pre-post difference in BP estimation of Galaxy Watch. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-3. [PMID: 38083749 DOI: 10.1109/embc40787.2023.10340129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
The use of smartwatches has become increasingly common with the release of major products such as the Galaxy Watch by Samsung and the Apple Watch by Apple. The common aim of smartwatches is to target the healthcare market with a wearable, physically-attached device, with blood pressure at the core. As blood pressure is an important biomarker for cardiovascular-related diseases, it is a necessary index to inspect in hospitals when checking an individual's health state. Smartwatches are expected to provide a cuff-less, non-invasive method of estimating blood pressure. However, not many experiments have been conducted on blood pressure datasets obtained from smartwatches. Smartwatches are unique compared to other devices because they require "calibration" to sustain their accuracy.In this paper, we investigate the difference between before and after calibration to better understand the calibration pattern. Not only do we seek to understand the demographic differences in calibration, but we also analyze the possible variables that influence calibration differences. Our results show that hypertensive patients are more prone to high calibration differences, which implies that the calibration period should be adjusted by considering the average blood pressure of users.Clinical Relevance- This paper investigates the possibility for daily BP measurement to be used as clinical data while suggesting proper method to sustain its validity.
Collapse
|
12
|
Abdullah S, Hafid A, Folke M, Lindén M, Kristoffersson A. PPGFeat: a novel MATLAB toolbox for extracting PPG fiducial points. Front Bioeng Biotechnol 2023; 11:1199604. [PMID: 37378045 PMCID: PMC10292016 DOI: 10.3389/fbioe.2023.1199604] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 05/26/2023] [Indexed: 06/29/2023] Open
Abstract
Photoplethysmography is a non-invasive technique used for measuring several vital signs and for the identification of individuals with an increased disease risk. Its principle of work is based on detecting changes in blood volume in the microvasculature of the skin through the absorption of light. The extraction of relevant features from the photoplethysmography signal for estimating certain physiological parameters is a challenging task, where various feature extraction methods have been proposed in the literature. In this work, we present PPGFeat, a novel MATLAB toolbox supporting the analysis of raw photoplethysmography waveform data. PPGFeat allows for the application of various preprocessing techniques, such as filtering, smoothing, and removal of baseline drift; the calculation of photoplethysmography derivatives; and the implementation of algorithms for detecting and highlighting photoplethysmography fiducial points. PPGFeat includes a graphical user interface allowing users to perform various operations on photoplethysmography signals and to identify, and if required also adjust, the fiducial points. Evaluating the PPGFeat's performance in identifying the fiducial points present in the publicly available PPG-BP dataset, resulted in an overall accuracy of 99% and 3038/3066 fiducial points were correctly identified. PPGFeat significantly reduces the risk of errors in identifying inaccurate fiducial points. Thereby, it is providing a valuable new resource for researchers for the analysis of photoplethysmography signals.
Collapse
|
13
|
Fleischhauer V, Bruhn J, Rasche S, Zaunseder S. Photoplethysmography upon cold stress-impact of measurement site and acquisition mode. Front Physiol 2023; 14:1127624. [PMID: 37324389 PMCID: PMC10267461 DOI: 10.3389/fphys.2023.1127624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 05/15/2023] [Indexed: 06/17/2023] Open
Abstract
Photoplethysmography (PPG) allows various statements about the physiological state. It supports multiple recording setups, i.e., application to various body sites and different acquisition modes, rendering the technique a versatile tool for various situations. Owing to anatomical, physiological and metrological factors, PPG signals differ with the actual setup. Research on such differences can deepen the understanding of prevailing physiological mechanisms and path the way towards improved or novel methods for PPG analysis. The presented work systematically investigates the impact of the cold pressor test (CPT), i.e., a painful stimulus, on the morphology of PPG signals considering different recording setups. Our investigation compares contact PPG recorded at the finger, contact PPG recorded at the earlobe and imaging PPG (iPPG), i.e., non-contact PPG, recorded at the face. The study bases on own experimental data from 39 healthy volunteers. We derived for each recording setup four common morphological PPG features from three intervals around CPT. For the same intervals, we derived blood pressure and heart rate as reference. To assess differences between the intervals, we used repeated measures ANOVA together with paired t-tests for each feature and we calculated Hedges' g to quantify effect sizes. Our analyses show a distinct impact of CPT. As expected, blood pressure shows a highly significant and persistent increase. Independently of the recording setup, all PPG features show significant changes upon CPT as well. However, there are marked differences between recording setups. Effect sizes generally differ with the finger PPG showing the strongest response. Moreover, one feature (pulse width at half amplitude) shows an inverse behavior in finger PPG and head PPG (earlobe PPG and iPPG). In addition, iPPG features behave partially different from contact PPG features as they tend to return to baseline values while contact PPG features remain altered. Our findings underline the importance of recording setup and physiological as well as metrological differences that relate to the setups. The actual setup must be considered in order to properly interpret features and use PPG. The existence of differences between recording setups and a deepened knowledge on such differences might open up novel diagnostic methods in the future.
Collapse
Affiliation(s)
- Vincent Fleischhauer
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
| | - Jan Bruhn
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
| | - Stefan Rasche
- Faculty of Medicine Carl Gustav Carus, TU Dresden, Dresden, Germany
| | - Sebastian Zaunseder
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
- Professorship for Diagnostic Sensing, Faculty of Applied Computer Science, University Augsburg, Augsburg, Germany
| |
Collapse
|
14
|
Rovas G, Bikia V, Stergiopulos N. Quantification of the Phenomena Affecting Reflective Arterial Photoplethysmography. Bioengineering (Basel) 2023; 10:bioengineering10040460. [PMID: 37106647 PMCID: PMC10136360 DOI: 10.3390/bioengineering10040460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/06/2023] [Accepted: 04/08/2023] [Indexed: 04/29/2023] Open
Abstract
Photoplethysmography (PPG) is a widely emerging method to assess vascular health in humans. The origins of the signal of reflective PPG on peripheral arteries have not been thoroughly investigated. We aimed to identify and quantify the optical and biomechanical processes that influence the reflective PPG signal. We developed a theoretical model to describe the dependence of reflected light on the pressure, flow rate, and the hemorheological properties of erythrocytes. To verify the theory, we designed a silicone model of a human radial artery, inserted it in a mock circulatory circuit filled with porcine blood, and imposed static and pulsatile flow conditions. We found a positive, linear relationship between the pressure and the PPG and a negative, non-linear relationship, of comparable magnitude, between the flow and the PPG. Additionally, we quantified the effects of the erythrocyte disorientation and aggregation. The theoretical model based on pressure and flow rate yielded more accurate predictions, compared to the model using pressure alone. Our results indicate that the PPG waveform is not a suitable surrogate for intraluminal pressure and that flow rate significantly affects PPG. Further validation of the proposed methodology in vivo could enable the non-invasive estimation of arterial pressure from PPG and increase the accuracy of health-monitoring devices.
Collapse
Affiliation(s)
- Georgios Rovas
- Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology Lausanne, 1015 Lausanne, Switzerland
| | - Vasiliki Bikia
- Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology Lausanne, 1015 Lausanne, Switzerland
| | - Nikolaos Stergiopulos
- Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology Lausanne, 1015 Lausanne, Switzerland
| |
Collapse
|
15
|
Hu X, Yin S, Zhang X, Menon C, Fang C, Chen Z, Elgendi M, Liang Y. Blood pressure stratification using photoplethysmography and light gradient boosting machine. Front Physiol 2023; 14:1072273. [PMID: 36891146 PMCID: PMC9986584 DOI: 10.3389/fphys.2023.1072273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 02/06/2023] [Indexed: 02/22/2023] Open
Abstract
Introduction: Globally, hypertension (HT) is a substantial risk factor for cardiovascular disease and mortality; hence, rapid identification and treatment of HT is crucial. In this study, we tested the light gradient boosting machine (LightGBM) machine learning method for blood pressure stratification based on photoplethysmography (PPG), which is used in most wearable devices. Methods: We used 121 records of PPG and arterial blood pressure (ABP) signals from the Medical Information Mart for Intensive Care III public database. PPG, velocity plethysmography, and acceleration plethysmography were used to estimate blood pressure; the ABP signals were used to determine the blood pressure stratification categories. Seven feature sets were established and used to train the Optuna-tuned LightGBM model. Three trials compared normotension (NT) vs. prehypertension (PHT), NT vs. HT, and NT + PHT vs. HT. Results: The F1 scores for these three classification trials were 90.18%, 97.51%, and 92.77%, respectively. The results showed that combining multiple features from PPG and its derivative led to a more accurate classification of HT classes than using features from only the PPG signal. Discussion: The proposed method showed high accuracy in stratifying HT risks, providing a noninvasive, rapid, and robust method for the early detection of HT, with promising applications in the field of wearable cuffless blood pressure measurement.
Collapse
Affiliation(s)
- Xudong Hu
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China
| | - Shimin Yin
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China
| | - Xizhuang Zhang
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
| | - Carlo Menon
- Biomedical and Mobile Health Technology Lab, ETH Zurich, Zurich, Switzerland
| | - Cheng Fang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China
| | - Zhencheng Chen
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China.,Guangxi Colleges and Universities Key Laboratory of Biomedical Sensors and Intelligent Instruments, Guilin, China.,Guangxi Engineering Technology Research Center of Human Physiological Information Noninvasive Detection, Guilin, China
| | - Mohamed Elgendi
- Biomedical and Mobile Health Technology Lab, ETH Zurich, Zurich, Switzerland
| | - Yongbo Liang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China.,Guangxi Colleges and Universities Key Laboratory of Biomedical Sensors and Intelligent Instruments, Guilin, China.,Guangxi Engineering Technology Research Center of Human Physiological Information Noninvasive Detection, Guilin, China
| |
Collapse
|
16
|
Mahmud S, Ibtehaz N, Khandakar A, Sohel Rahman M, JR. Gonzales A, Rahman T, Shafayet Hossain M, Sakib Abrar Hossain M, Ahasan Atick Faisal M, Fuad Abir F, Musharavati F, E. H. Chowdhury M. NABNet: A Nested Attention-guided BiConvLSTM network for a robust prediction of Blood Pressure components from reconstructed Arterial Blood Pressure waveforms using PPG and ECG signals. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
17
|
Pilz N, Patzak A, Bothe TL. Continuous cuffless and non-invasive measurement of arterial blood pressure—concepts and future perspectives. Blood Press 2022; 31:254-269. [DOI: 10.1080/08037051.2022.2128716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Affiliation(s)
- Niklas Pilz
- Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute for Translational Physiology, Berlin, Germany
| | - Andreas Patzak
- Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute for Translational Physiology, Berlin, Germany
| | - Tomas L. Bothe
- Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute for Translational Physiology, Berlin, Germany
| |
Collapse
|
18
|
Khan Mamun MMR, Sherif A. Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010027. [PMID: 36671599 PMCID: PMC9854981 DOI: 10.3390/bioengineering10010027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022]
Abstract
Hypertension is a chronic condition that is one of the prominent reasons behind cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the deterioration in a health condition could even result in mortality. If it can be detected early, with proper treatment, undesirable outcomes can be avoided. Until now, the gold standard is the invasive way of measuring blood pressure (BP) using a catheter. Additionally, the cuff-based and noninvasive methods are too cumbersome or inconvenient for frequent measurement of BP. With the advancement of sensor technology, signal processing techniques, and machine learning algorithms, researchers are trying to find the perfect relationships between biomedical signals and changes in BP. This paper is a literature review of the studies conducted on the cuffless noninvasive measurement of BP using biomedical signals. Relevant articles were selected using specific criteria, then traditional techniques for BP measurement were discussed along with a motivation for cuffless measurement use of biomedical signals and machine learning algorithms. The review focused on the progression of different noninvasive cuffless techniques rather than comparing performance among different studies. The literature survey concluded that the use of deep learning proved to be the most accurate among all the cuffless measurement techniques. On the other side, this accuracy has several disadvantages, such as lack of interpretability, computationally extensive, standard validation protocol, and lack of collaboration with health professionals. Additionally, the continuing work by researchers is progressing with a potential solution for these challenges. Finally, future research directions have been provided to encounter the challenges.
Collapse
Affiliation(s)
| | - Ahmed Sherif
- School of Computing Sciences and Computer Engineering, The University of Southern Mississippi, Hattiesburg, MS 39406, USA
| |
Collapse
|
19
|
Konstantinidis D, Iliakis P, Tatakis F, Thomopoulos K, Dimitriadis K, Tousoulis D, Tsioufis K. Wearable blood pressure measurement devices and new approaches in hypertension management: the digital era. J Hum Hypertens 2022; 36:945-951. [PMID: 35322181 PMCID: PMC8942176 DOI: 10.1038/s41371-022-00675-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 02/13/2022] [Accepted: 03/09/2022] [Indexed: 11/09/2022]
Abstract
Out-of-office blood pressure (BP) measurement is considered an integral component of the diagnostic algorithm and management of hypertension. In the era of digitalization, a great deal of wearable BP measuring devices has been developed. These digital blood pressure monitors allow frequent BP measurements with minimal annoyance to the patient while they do promise radical changes regarding the diagnostic accuracy, as the importance of making an accurate diagnosis of hypertension has become evident. By increasing the number of BP measurements in different conditions, these monitors allow accurate identification of different clinical phenotypes, such as masked hypertension and pathological BP variability, that seem to have a negative impact on cardiovascular prognosis. Frequent measurements of BP and the incorporation of new features in BP variability, both enable well-rounded interpretation of BP data in the context of real-life settings. This article is a review of all different technologies and wearable BP monitoring devices.
Collapse
Affiliation(s)
- D Konstantinidis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece.
| | - P Iliakis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece
| | - F Tatakis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece
| | - K Thomopoulos
- Department of Cardiology, Helena Venizelou Hospital, Athens, Greece
| | - K Dimitriadis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece
| | - D Tousoulis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece
| | - K Tsioufis
- First Cardiology Clinic, Medical School, National and Kapodistrian University of Athens, Hippokration Hospital, Athens, Greece
| |
Collapse
|
20
|
Andreozzi E, Sabbadini R, Centracchio J, Bifulco P, Irace A, Breglio G, Riccio M. Multimodal Finger Pulse Wave Sensing: Comparison of Forcecardiography and Photoplethysmography Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197566. [PMID: 36236663 PMCID: PMC9570799 DOI: 10.3390/s22197566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 09/26/2022] [Accepted: 10/01/2022] [Indexed: 05/31/2023]
Abstract
Pulse waves (PWs) are mechanical waves that propagate from the ventricles through the whole vascular system as brisk enlargements of the blood vessels' lumens, caused by sudden increases in local blood pressure. Photoplethysmography (PPG) is one of the most widespread techniques employed for PW sensing due to its ability to measure blood oxygen saturation. Other sensors and techniques have been proposed to record PWs, and include applanation tonometers, piezoelectric sensors, force sensors of different kinds, and accelerometers. The performances of these sensors have been analyzed individually, and their results have been found not to be in good agreement (e.g., in terms of PW morphology and the physiological parameters extracted). Such a comparison has led to a deeper comprehension of their strengths and weaknesses, and ultimately, to the consideration that a multimodal approach accomplished via sensor fusion would lead to a more robust, reliable, and potentially more informative methodology for PW monitoring. However, apart from various multichannel and multi-site systems proposed in the literature, no true multimodal sensors for PW recording have been proposed yet that acquire PW signals simultaneously from the same measurement site. In this study, a true multimodal PW sensor is presented, which was obtained by integrating a piezoelectric forcecardiography (FCG) sensor and a PPG sensor, thus enabling simultaneous mechanical-optical measurements of PWs from the same site on the body. The novel sensor performance was assessed by measuring the finger PWs of five healthy subjects at rest. The preliminary results of this study showed, for the first time, that a delay exists between the PWs recorded simultaneously by the PPG and FCG sensors. Despite such a delay, the pulse waveforms acquired by the PPG and FCG sensors, along with their first and second derivatives, had very high normalized cross-correlation indices in excess of 0.98. Six well-established morphological parameters of the PWs were compared via linear regression, correlation, and Bland-Altman analyses, which showed that some of these parameters were not in good agreement for all subjects. The preliminary results of this proof-of-concept study must be confirmed in a much larger cohort of subjects. Further investigation is also necessary to shed light on the physical origin of the observed delay between optical and mechanical PW signals. This research paves the way for the development of true multimodal, wearable, integrated sensors and for potential sensor fusion approaches to improve the performance of PW monitoring at various body sites.
Collapse
|
21
|
The Use of Smart Devices for Mental Health Diagnosis and Care. J Clin Med 2022; 11:jcm11185359. [PMID: 36143004 PMCID: PMC9501104 DOI: 10.3390/jcm11185359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 09/10/2022] [Indexed: 11/17/2022] Open
Abstract
In 2019, more than 970 million people worldwide suffered from a mental disorder, with anxiety and depressive disorders as the leading culprits [...]
Collapse
|
22
|
Comparison of pulse rate variability and morphological features of photoplethysmograms in estimation of blood pressure. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
23
|
Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. J Hypertens 2022; 40:1449-1460. [PMID: 35708294 DOI: 10.1097/hjh.0000000000003224] [Citation(s) in RCA: 70] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Many cuffless blood pressure (BP) measuring devices are currently on the market claiming that they provide accurate BP measurements. These technologies have considerable potential to improve the awareness, treatment, and management of hypertension. However, recent guidelines by the European Society of Hypertension do not recommend cuffless devices for the diagnosis and management of hypertension. OBJECTIVE This statement by the European Society of Hypertension Working Group on BP Monitoring and Cardiovascular Variability presents the types of cuffless BP technologies, issues in their validation, and recommendations for clinical practice. STATEMENTS Cuffless BP monitors constitute a wide and heterogeneous group of novel technologies and devices with different intended uses. Cuffless BP devices have specific accuracy issues, which render the established validation protocols for cuff BP devices inadequate for their validation. In 2014, the Institute of Electrical and Electronics Engineers published a standard for the validation of cuffless BP devices, and the International Organization for Standardization is currently developing another standard. The validation of cuffless devices should address issues related to the need of individual cuff calibration, the stability of measurements post calibration, the ability to track BP changes, and the implementation of machine learning technology. Clinical field investigations may also be considered and issues regarding the clinical implementation of cuffless BP readings should be investigated. CONCLUSION Cuffless BP devices have considerable potential for changing the diagnosis and management of hypertension. However, fundamental questions regarding their accuracy, performance, and implementation need to be carefully addressed before they can be recommended for clinical use.
Collapse
|
24
|
Charlton PH, Paliakaitė B, Pilt K, Bachler M, Zanelli S, Kulin D, Allen J, Hallab M, Bianchini E, Mayer CC, Terentes-Printzios D, Dittrich V, Hametner B, Veerasingam D, Žikić D, Marozas V. Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet. Am J Physiol Heart Circ Physiol 2022; 322:H493-H522. [PMID: 34951543 PMCID: PMC8917928 DOI: 10.1152/ajpheart.00392.2021] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 12/21/2021] [Accepted: 12/21/2021] [Indexed: 12/07/2022]
Abstract
The photoplethysmogram (PPG) signal is widely measured by clinical and consumer devices, and it is emerging as a potential tool for assessing vascular age. The shape and timing of the PPG pulse wave are both influenced by normal vascular aging, changes in arterial stiffness and blood pressure, and atherosclerosis. This review summarizes research into assessing vascular age from the PPG. Three categories of approaches are described: 1) those which use a single PPG signal (based on pulse wave analysis), 2) those which use multiple PPG signals (such as pulse transit time measurement), and 3) those which use PPG and other signals (such as pulse arrival time measurement). Evidence is then presented on the performance, repeatability and reproducibility, and clinical utility of PPG-derived parameters of vascular age. Finally, the review outlines key directions for future research to realize the full potential of photoplethysmography for assessing vascular age.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom
- Research Centre for Biomedical Engineering, University of London, London, United Kingdom
| | - Birutė Paliakaitė
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| | - Kristjan Pilt
- Department of Health Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Martin Bachler
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Serena Zanelli
- Laboratoire Analyze, Géométrie et Applications, University Sorbonne Paris Nord, Paris, France
- Axelife, Redon, France
| | - Dániel Kulin
- Institute of Translational Medicine, Semmelweis University, Budapest, Hungary
- E-Med4All Europe, Limited, Budapest, Hungary
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Magid Hallab
- Axelife, Redon, France
- Centre de recherche et d'Innovation, Clinique Bizet, Paris, France
| | | | - Christopher C Mayer
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Dimitrios Terentes-Printzios
- Hypertension and Cardiometabolic Unit, First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Verena Dittrich
- Redwave Medical, Gesellschaft mit beschränkter Haftung, Jena, Germany
| | - Bernhard Hametner
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Dave Veerasingam
- Department of Cardiothoracic Surgery, Galway University Hospitals, Galway, Ireland
| | - Dejan Žikić
- Faculty of Medicine, Institute of Biophysics, University of Belgrade, Belgrade, Serbia
| | - Vaidotas Marozas
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| |
Collapse
|
25
|
Charlton PH, Kyriacou PA, Mant J, Marozas V, Chowienczyk P, Alastruey J. Wearable Photoplethysmography for Cardiovascular Monitoring. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:355-381. [PMID: 35356509 PMCID: PMC7612541 DOI: 10.1109/jproc.2022.3149785] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 01/06/2022] [Accepted: 01/27/2022] [Indexed: 05/29/2023]
Abstract
Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.
Collapse
Affiliation(s)
- Peter H. Charlton
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health PartnersLondonSE1 7EUU.K.
- Research Centre for Biomedical Engineering, CityUniversity of LondonLondonEC1V 0HBU.K.
- Department of Public Health and Primary CareUniversity of CambridgeCambridgeCB1 8RNU.K.
| | - Panicos A. Kyriacou
- Research Centre for Biomedical Engineering, CityUniversity of LondonLondonEC1V 0HBU.K.
| | - Jonathan Mant
- Department of Public Health and Primary CareUniversity of CambridgeCambridgeCB1 8RNU.K.
| | - Vaidotas Marozas
- Department of Electronics Engineering and the Biomedical Engineering Institute, Kaunas University of Technology44249KaunasLithuania
| | - Phil Chowienczyk
- Department of Clinical PharmacologyKing’s College LondonLondonSE1 7EHU.K.
| | - Jordi Alastruey
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health PartnersLondonSE1 7EUU.K.
| |
Collapse
|
26
|
Solé Morillo Á, Lambert Cause J, Baciu VE, da Silva B, Garcia-Naranjo JC, Stiens J. PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities. SENSORS 2022; 22:s22041389. [PMID: 35214290 PMCID: PMC8963096 DOI: 10.3390/s22041389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/20/2022] [Accepted: 02/01/2022] [Indexed: 02/01/2023]
Abstract
The grown interest in healthcare applications has made biomedical engineering one of the fastest growing disciplines in recent years. Photoplethysmography (PPG) has gained popularity in recent years due to its versatility for noninvasive monitoring of vital signs such as heart rate, respiratory rate, blood oxygen saturation and blood pressure. In this work, an adjustable PPG-based educational device called PPG EduKit, which aims to facilitate the learning of the PPG technology for a wide range of engineering and medical disciplines is proposed. Through the use of this educational platform, the PPG signal can be understood, modified and implemented along with the extraction of its relevant physiological information from a didactic, intuitive and practical way. The PPG Edukit is evaluated for the extraction of physiological parameters such as heart rate and blood oxygen level, demonstrating how its features contribute to engineering and medical students to assimilate technical concepts in electrical circuits, biomedical instrumentation, and human physiology.
Collapse
Affiliation(s)
- Ángel Solé Morillo
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (V.-E.B.); (J.S.)
- Correspondence: (A.S.M.); (J.L.C.); (B.d.S.)
| | - Joan Lambert Cause
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (V.-E.B.); (J.S.)
- Department of Biomedical Engineering, Universidad de Oriente, Santiago de Cuba 90500, Cuba
- Correspondence: (A.S.M.); (J.L.C.); (B.d.S.)
| | - Vlad-Eusebiu Baciu
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (V.-E.B.); (J.S.)
| | - Bruno da Silva
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (V.-E.B.); (J.S.)
- Correspondence: (A.S.M.); (J.L.C.); (B.d.S.)
| | - Juan C. Garcia-Naranjo
- Biophysics and Medical Physics Center, Universidad de Oriente, Santiago de Cuba 90500, Cuba;
| | - Johan Stiens
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium; (V.-E.B.); (J.S.)
| |
Collapse
|
27
|
Cuffless Blood Pressure Measurement Using Linear and Nonlinear Optimized Feature Selection. Diagnostics (Basel) 2022; 12:diagnostics12020408. [PMID: 35204499 PMCID: PMC8870879 DOI: 10.3390/diagnostics12020408] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 01/30/2022] [Accepted: 01/30/2022] [Indexed: 02/04/2023] Open
Abstract
The cuffless blood pressure (BP) measurement allows for frequent measurement without discomfort to the patient compared to the cuff inflation measurement. With the availability of a large dataset containing physiological waveforms, now it is possible to use them through different learning algorithms to produce a relationship with changes in BP. In this paper, a novel cuffless noninvasive blood pressure measurement technique has been proposed using optimized features from electrocardiogram and photoplethysmography based on multivariate symmetric uncertainty (MSU). The technique is an improvement over other contemporary methods due to the inclusion of feature optimization depending on both linear and nonlinear relationships with the change of blood pressure. MSU has been used as a selection criterion with algorithms such as the fast correlation and ReliefF algorithms followed by the penalty-based regression technique to make sure the features have maximum relevance as well as minimum redundancy. The result from the technique was compared with the performance of similar techniques using the MIMIC-II dataset. After training and testing, the root mean square error (RMSE) comes as 5.28 mmHg for systolic BP and 5.98 mmHg for diastolic BP. In addition, in terms of mean absolute error, the result improved to 4.27 mmHg for SBP and 5.01 for DBP compared to recent cuffless BP measurement techniques which have used substantially large datasets and feature optimization. According to the British Hypertension Society Standard (BHS), our proposed technique achieved at least grade B in all cumulative criteria for cuffless BP measurement.
Collapse
|
28
|
Migueis DP, Urel A, dos Santos CC, Accetta A, Burla M. The cardiovascular, metabolic, fetal and neonatal effects of CPAP use in pregnant women: a systematic review. Sleep Sci 2022; 15:264-277. [PMID: 35273777 PMCID: PMC8889985 DOI: 10.5935/1984-0063.20210024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Continuous positive airway pressure (CPAP) is the standard treatment for obstructive sleep apnea (OSA), but its outcomes for the pregnant are still undefined. This study aims to review current CPAP intervention during pregnancy, discuss published trials, and propose relevant issues that have yet to be addressed satisfactorily about the cardiovascular, metabolic, fetal, and neonatal effects of CPAP treatment during gestation. Two authors independently conducted a systematic review until March 28th, 2021 on PubMed, BVS, and Cochrane Library, using PRISMA guidelines, and risk of bias. Discrepancies were reconciled by a third reviewer. Of 59 identified citations, eight original trials have submitted a total of 90 pregnant women to polysomnography and CPAP therapy. Four studies performed in samples with hypertension or preeclampsia presented blood pressure decrease or maintained the antihypertensive drug dose in the CPAP group. After CPAP utilization, one trial registered cardiac output and stroke volume increase with heart rate and peripheral vascular resistance decrease, which were correlated with birth weight increment. Others documented a higher Apgar in the CPAP group and more fetal movements during CPAP use. There was a reduction in serum uric acid and tumor necrosis factor-alpha in the CPAP groups whose blood pressure decreased. However, two weeks of CPAP use in women with gestational diabetes and OSA did not improve glucose levels but raised the insulin secretion in those adherents to CPAP. Despite these positive results without adverse effects, randomized controlled trials with standardized follow-up in larger populations are required to determine CPAP therapy recommendations in pregnancy.
Collapse
Affiliation(s)
| | - Arthur Urel
- Federal Fluminense University, General and specialized surgery - Niterói - RJ -Brazil
| | | | - Andre Accetta
- Federal Fluminense University, General and specialized surgery - Niterói - RJ -Brazil
| | - Marcelo Burla
- Federal Fluminense University, General and specialized surgery - Niterói - RJ -Brazil
| |
Collapse
|
29
|
Considering blood scattering effect in noninvasive optical detection of blood components using dynamic spectrum along with time varying filter based empirical mode decomposition. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103266] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
30
|
Xing X, Ma Z, Xu S, Zhang M, Zhao W, Song M, Dong WF. Blood pressure assessment with in-ear photoplethysmography. Physiol Meas 2021; 42. [PMID: 34571491 DOI: 10.1088/1361-6579/ac2a71] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/27/2021] [Indexed: 11/11/2022]
Abstract
Objective. In this study, we aimed to estimate blood pressure (BP) from in-ear photoplethysmography (PPG). This novel implementation provided an unobtrusive and steady way of recording PPG, whereas previous PPG measurements were mostly performed at the wrist, finger, or earlobe.Methods. The time between forward and reflected PPG waves was very short at the ear site. To minimize errors introduced by feature extraction, a multi-Gaussian decomposition of in-ear PPG was performed. Both hand-crafted and whole-based features were extracted and the best combination of features was selected using a backward-search wrapper method and evaluated by the Akaike information criteria. Hemodynamic parameters such as compliance and inertance were estimated from a four-element Windkessel (WK4) model, which was used to pre-classify PPG signals and generate different BP estimation algorithms. Calibration was done by using previous measurements from the same class. To validate this novel approach, 53 subjects were recruited for a one-month follow-up study, and 17 subjects were recruited for a two-month follow-up study. Calibrated systolic BP estimation accuracy was significantly improved with inertance-based pre-classification, while diastolic BP showed less improvement.Results. With proper feature selection, pre-classification and calibration, we have achieved a mean absolute error of 5.35 mmHg for SBP estimation, compared to 6.16 mmHg if no pre-classification was carried out. The performance did not deteriorate in two months, showing a decent BP trend-tracking ability.Conclusion. The study demonstrated the feasibility of in-ear PPG to reliably measure BP, which represents an important technological advancement in terms of unobtrusiveness and steadiness.
Collapse
Affiliation(s)
- Xiaoman Xing
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Sciences and Technology of China, Suzhou, Jiangsu, People's Republic of China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, People's Republic of China
| | - Zhimin Ma
- The Affiliated Suzhou Science &Technology Town Hospital of Nanjing Medical University, Suzhou, Jiangsu, People's Republic of China
| | - Shengkai Xu
- The Affiliated Suzhou Science &Technology Town Hospital of Nanjing Medical University, Suzhou, Jiangsu, People's Republic of China
| | - Mingyou Zhang
- The First Hospital of Jilin University, Changchun, Jilin, People's Republic of China
| | - Wei Zhao
- Department of Otolaryngology-Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Mingxuan Song
- Jinan Guoke Medical Technology Development Co., Ltd, Shandong, People's Republic of China
| | - Wen-Fei Dong
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, People's Republic of China
| |
Collapse
|
31
|
Mejía-Mejía E, May JM, Elgendi M, Kyriacou PA. Classification of blood pressure in critically ill patients using photoplethysmography and machine learning. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106222. [PMID: 34166851 DOI: 10.1016/j.cmpb.2021.106222] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 05/26/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate the capability of features extracted from photoplethysmography (PPG) based Pulse Rate Variability (PRV) to classify hypertensive, normotensive and hypotensive events, and to estimate mean arterial, systolic and diastolic blood pressure in critically ill patients. METHODS Time-domain, frequency-domain and non-linear indices from PRV were extracted from 5-min and 1-min segments obtained from PPG signals. These features were filtered using machine learning algorithms in order to obtain the optimal combination for the classification of hypertensive, hypotensive and normotensive events, and for the estimation of blood pressure. RESULTS 5-min segments allowed for an improved performance in both classification and estimation tasks. Classification of blood pressure states showed around 70% accuracy and around 75% specificity. The sensitivity, precision and F1 scores were around 50%. In estimating mean arterial, systolic, and diastolic blood pressure, mean absolute errors as low as 2.55 ± 0.78 mmHg, 4.74 ± 2.33 mmHg, and 1.78 ± 0.14 mmHg were obtained, respectively. Bland-Altman analysis and Wilcoxon rank sum tests showed good agreement between real and estimated values, especially for mean and diastolic arterial blood pressures. CONCLUSION PRV-based features could be used for the classification of blood pressure states and the estimation of blood pressure values, although including additional features from the PPG waveform could improve the results. SIGNIFICANCE PRV contains information related to blood pressure, which may aid in the continuous, noninvasive, non-intrusive estimation of blood pressure and detection of hypertensive and hypotensive events in critically ill subjects.
Collapse
Affiliation(s)
- Elisa Mejía-Mejía
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom.
| | - James M May
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom
| | | | - Panayiotis A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom
| |
Collapse
|
32
|
Henrique Rufino Batista L, Jorge Ribeiro Domingues W, de Athayde Costa e Silva A, Augusta Thomé Lopes K, Leopoldina de Castro Amorim M, Rossato M. Heart rate variability responses determined by photoplethysmography in people with spinal cord injury. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
33
|
Allen J, Liu H, Iqbal S, Zheng D, Stansby G. Deep learning-based photoplethysmography classification for peripheral arterial disease detection: a proof-of-concept study. Physiol Meas 2021; 42. [PMID: 33878743 DOI: 10.1088/1361-6579/abf9f3] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 04/20/2021] [Indexed: 11/12/2022]
Abstract
Objective.A proof-of-concept study to assess the potential of a deep learning (DL) based photoplethysmography PPG ('DLPPG') classification method to detect peripheral arterial disease (PAD) using toe PPG signals.Approach.PPG spectrogram images derived from our previously published multi-site PPG datasets (214 participants; 31.3% legs with PAD by ankle brachial pressure index (ABPI)) were input into a pretrained 8-layer (five convolutional layers + three fully connected layers) AlexNet as tailored to the 2-class problem with transfer learning to fine tune the convolutional neural network (CNN).k-fold random cross validation (CV) was performed (fork = 5 andk = 10), with each evaluated over k training/validation runs. Overall test sensitivity, specificity, accuracy, and Cohen's Kappa statistic with 95% confidence interval ranges were calculated and compared, as well as sensitivities in detecting mild-moderate (0.5 ≤ ABPI < 0.9) and major (ABPI < 0.5) levels of PAD.Main results.CV with eitherk = 5 or 10 folds gave similar diagnostic performances. The overall test sensitivity was 86.6%, specificity 90.2% and accuracy 88.9% (Kappa: 0.76 [0.70-0.82]) (atk= 5). The sensitivity to mild-moderate disease was 83.0% (75.5%-88.9%) and to major disease was 100.0% (90.5%-100.0%).Significance.Substantial agreements have been demonstrated between the DL-based PPG classification technique and the ABPI PAD diagnostic reference. This novel automatic approach, requiring minimal pre-processing of the pulse waveforms before PPG trace classification, could offer significant benefits for the diagnosis of PAD in a variety of clinical settings where low-cost, portable and easy-to-use diagnostics are desirable.
Collapse
Affiliation(s)
- John Allen
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Research Centre for Intelligent Healthcare, Coventry University, United Kingdom.,Northern Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - Haipeng Liu
- Research Centre for Intelligent Healthcare, Coventry University, United Kingdom
| | - Sadaf Iqbal
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Northern Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - Dingchang Zheng
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Research Centre for Intelligent Healthcare, Coventry University, United Kingdom
| | - Gerard Stansby
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne. United Kingdom
| |
Collapse
|
34
|
Bird K, Chan G, Lu H, Greeff H, Allen J, Abbott D, Menon C, Lovell NH, Howard N, Chan WS, Fletcher RR, Alian A, Ward R, Elgendi M. Assessment of Hypertension Using Clinical Electrocardiogram Features: A First-Ever Review. Front Med (Lausanne) 2020; 7:583331. [PMID: 33344473 PMCID: PMC7746856 DOI: 10.3389/fmed.2020.583331] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/16/2020] [Indexed: 12/31/2022] Open
Abstract
Hypertension affects an estimated 1.4 billion people and is a major cause of morbidity and mortality worldwide. Early diagnosis and intervention can potentially decrease cardiovascular events later in life. However, blood pressure (BP) measurements take time and require training for health care professionals. The measurements are also inconvenient for patients to access, numerous daily variables affect BP values, and only a few BP readings can be collected per session. This leads to an unmet need for an accurate, 24-h continuous, and portable BP measurement system. Electrocardiograms (ECGs) have been considered as an alternative way to measure BP and may meet this need. This review summarizes the literature published from January 1, 2010, to January 1, 2020, on the use of only ECG wave morphology to monitor BP or identify hypertension. From 35 articles analyzed (9 of those with no listed comorbidities and confounders), the P wave, QTc intervals and TpTe intervals may be promising for this purpose. Unfortunately, with the limited number of articles and the variety of participant populations, we are unable to make conclusions about the effectiveness of ECG-only BP monitoring. We provide 13 recommendations for future ECG-only BP monitoring studies and highlight the limited findings in pregnant and pediatric populations. With the advent of convenient and portable ECG signal recording in smart devices and wearables such as watches, understanding how to apply ECG-only findings to identify hypertension early is crucial to improving health outcomes worldwide.
Collapse
Affiliation(s)
- Kathleen Bird
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Gabriel Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Huiqi Lu
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Heloise Greeff
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - John Allen
- Research Center for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
| | - Derek Abbott
- School of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA, Australia.,Center for Biomedical Engineering, The University of Adelaide, Adelaide, SA, Australia
| | - Carlo Menon
- School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC, Canada
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, NSW, Australia
| | - Newton Howard
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, United Kingdom
| | - Wee-Shian Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Richard Ribon Fletcher
- D-Lab, Massachusetts Institute of Technology, Cambridge, MA, United States.,Department of Psychiatry, University of Massachusetts Medical School, Worcester, MA, United States
| | - Aymen Alian
- Yale School of Medicine, Yale University, New Haven, CT, United States
| | - Rabab Ward
- School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
| | - Mohamed Elgendi
- Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.,School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC, Canada.,Nuffield Department of Surgical Sciences, University of Oxford, Oxford, United Kingdom.,School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada.,BC Children's & Women's Hospital, Vancouver, BC, Canada
| |
Collapse
|
35
|
Allen J, O'Sullivan J, Stansby G, Murray A. Age-related changes in pulse risetime measured by multi-site photoplethysmography. Physiol Meas 2020; 41:074001. [PMID: 32784270 DOI: 10.1088/1361-6579/ab9b67] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE It is accepted that changes in the peripheral pulse waveform characteristics occur with ageing. Pulse risetime is one important feature which has clinical value. However, it is unclear how it varies across the full age spectrum from child to senior and for different peripheral measurement sites. The objectives of this study were to determine the association between age and pulse risetime characteristics over an 8-decade age range at the ears, fingers, and toes, and to consider effects arising from differences in systolic blood pressure (SBP), height and heart rate. APPROACH Multi-site photoplethysmography (MPPG) pulse waveforms were recorded non-invasively from the right and left ears, fingers, and toes of 304 normal healthy human subjects (range 6-87 years; 156 male and 148 female). SBP, height, and heart rate were also measured. Multi-site PPG pulse risetimes, and their site differences, were determined. MAIN RESULTS Univariate regression analysis showed positive correlations with risetime for age (ears, fingers and toes: + 0.8, + 1.9, and + 1.1 ms/year, respectively), SBP (+0.5, + 1.3, and + 0.9 ms/mmHg) and height (+0.5, + 1.2, and + 1.0 ms/cm), but with a clear inverse association with heart rate (-1.8, - 2.5, and - 1.6 ms min) (P < 0.0001). No significant differences between male and female subjects were found for pulse risetime. SIGNIFICANCE Normative multi-site PPG risetime characteristics have been defined in over 300 subjects and are shown to increase with age linearly up to the 8th decade. In contrast, we have shown that heart rate has a clear inverse relationship with risetime for all measurement sites.
Collapse
Affiliation(s)
- John Allen
- Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5FB, United Kingdom. Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
| | | | | | | |
Collapse
|
36
|
Kario K. Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring. Hypertension 2020; 76:640-650. [PMID: 32755418 PMCID: PMC7418935 DOI: 10.1161/hypertensionaha.120.14742] [Citation(s) in RCA: 95] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Out-of-office blood pressure measurement is an essential part of diagnosing and managing hypertension. In the era of advanced digital health information technology, the approach to achieving this is shifting from traditional methods (ambulatory and home blood pressure monitoring) to wearable devices and technology. Wearable blood pressure monitors allow frequent blood pressure measurements (ideally continuous beat-by-beat monitoring of blood pressure) with minimal stress on the patient. It is expected that wearable devices will dramatically change the quality of detection and management of hypertension by increasing the number of measurements in different situations, allowing accurate detection of phenotypes that have a negative impact on cardiovascular prognosis, such as masked hypertension and abnormal blood pressure variability. Frequent blood pressure measurements and the addition of new features such as monitoring of environmental conditions allows interpretation of blood pressure data in the context of daily stressors and different situations. This new digital approach to hypertension contributes to anticipation medicine, which refers to strategies designed to identify increasing risk and predict the onset of cardiovascular events based on a series of data collected over time, allowing proactive interventions to reduce risk. To achieve this, further research and validation is required to develop wearable blood pressure monitoring devices that provide the same accuracy as current approaches and can effectively contribute to personalized medicine.
Collapse
Affiliation(s)
- Kazuomi Kario
- From the Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Shimotsuke, Tochigi, Japan; and the Hypertension Cardiovascular Outcome Prevention and Evidence in Asia (HOPE Asia) Network
| |
Collapse
|
37
|
Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension. J Clin Med 2020; 9:jcm9041203. [PMID: 32331360 PMCID: PMC7230564 DOI: 10.3390/jcm9041203] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/07/2020] [Accepted: 04/13/2020] [Indexed: 12/14/2022] Open
Abstract
Elevated blood pressure (BP) is a major cause of death, yet hypertension commonly goes undetected. Owing to its nature, it is typically asymptomatic until later in its progression when the vessel or organ structure has already been compromised. Therefore, noninvasive and continuous BP measurement methods are needed to ensure appropriate diagnosis and early management before hypertension leads to irreversible complications. Photoplethysmography (PPG) is a noninvasive technology with waveform morphologies similar to that of arterial BP waveforms, therefore attracting interest regarding its usability in BP estimation. In recent years, wearable devices incorporating PPG sensors have been proposed to improve the early diagnosis and management of hypertension. Additionally, the need for improved accuracy and convenience has led to the development of devices that incorporate multiple different biosignals with PPG. Through the addition of modalities such as an electrocardiogram, a final measure of the pulse wave velocity is derived, which has been proved to be inversely correlated to BP and to yield accurate estimations. This paper reviews and summarizes recent studies within the period 2010–2019 that combined PPG with other biosignals and offers perspectives on the strengths and weaknesses of current developments to guide future advancements in BP measurement. Our literature review reveals promising measurement accuracies and we comment on the effective combinations of modalities and success of this technology.
Collapse
|
38
|
Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR). BIOSENSORS-BASEL 2020; 10:bios10040034. [PMID: 32260393 PMCID: PMC7235881 DOI: 10.3390/bios10040034] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 04/01/2020] [Accepted: 04/02/2020] [Indexed: 11/30/2022]
Abstract
Photoplethysmography (PPG) is a valuable technique for noninvasively evaluating physiological parameters. However, traditional PPG devices have significant limitations in high-motion and low-perfusion environments. To overcome these limitations, we investigated the accuracy of a clinically novel PPG site using SPYDR®, a new PPG sensor suite, against arterial blood gas (ABG) measurements as well as other commercial PPG sensors at the finger and forehead in hypoxic environments. SPYDR utilizes a reflectance PPG sensor applied behind the ear, between the pinna and the hairline, on the mastoid process, above the sternocleidomastoid muscle, near the posterior auricular artery in a self-contained ear cup system. ABG revealed accuracy of SPYDR with a root mean square error of 2.61% at a 70–100% range, meeting FDA requirements for PPG sensor accuracy. Subjects were also instrumented with SPYDR, as well as finger and forehead PPG sensors, and pulse rate (PR) and oxygen saturation (SpO2) were measured and compared at various reduced oxygen profiles with a reduced oxygen breathing device (ROBD). SPYDR was shown to be as accurate as other sensors in reduced oxygen environments with a Pearson’s correlation >93% for PR and SpO2. In addition, SPYDR responded to changes in SpO2 up to 50 s faster than PPG measurements at the finger and forehead.
Collapse
|
39
|
Hosanee M, Chan G, Welykholowa K, Cooper R, Kyriacou PA, Zheng D, Allen J, Abbott D, Menon C, Lovell NH, Howard N, Chan WS, Lim K, Fletcher R, Ward R, Elgendi M. Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring. J Clin Med 2020; 9:E723. [PMID: 32155976 PMCID: PMC7141397 DOI: 10.3390/jcm9030723] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 03/03/2020] [Accepted: 03/05/2020] [Indexed: 12/12/2022] Open
Abstract
One in three adults worldwide has hypertension, which is associated with significant morbidity and mortality. Consequently, there is a global demand for continuous and non-invasive blood pressure (BP) measurements that are convenient, easy to use, and more accurate than the currently available methods for detecting hypertension. This could easily be achieved through the integration of single-site photoplethysmography (PPG) readings into wearable devices, although improved reliability and an understanding of BP estimation accuracy are essential. This review paper focuses on understanding the features of PPG associated with BP and examines the development of this technology over the 2010-2019 period in terms of validation, sample size, diversity of subjects, and datasets used. Challenges and opportunities to move single-site PPG forward are also discussed.
Collapse
Affiliation(s)
- Manish Hosanee
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Gabriel Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Kaylie Welykholowa
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Rachel Cooper
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Panayiotis A. Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK;
| | - Dingchang Zheng
- Research Center of Intelligent Healthcare, Faculty of Health and Life Science, Coventry University, Coventry CV1 5FB, UK;
| | - John Allen
- Northern Medical Physics and Clinical Engineering, Freeman Hospital, Newcastle upon Tyne NE7 7DN, UK;
| | - Derek Abbott
- School of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA 5005, Australia;
- Centre for Biomedical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia
| | - Carlo Menon
- School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC V5A 1S6, Canada;
| | - Nigel H. Lovell
- Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, NSW 2052, Australia;
| | - Newton Howard
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford OX3 9DU, UK;
| | - Wee-Shian Chan
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Kenneth Lim
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
| | - Richard Fletcher
- D-Lab, Massachusetts Institute of Technology, Cambridge, MA 02139, USA;
- Department of Psychiatry, University of Massachusetts Medical School, Worcester, MA 01655, USA
| | - Rabab Ward
- School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada;
| | - Mohamed Elgendi
- Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada; (M.H.); (G.C.); (K.W.); (R.C.); (W.-S.C.); (K.L.)
- School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC V5A 1S6, Canada;
- School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada;
- BC Children’s & Women’s Hospital, Vancouver, BC V6H 3N1, Canada
| |
Collapse
|
40
|
Wang H, Wang L, Sun N, Yao Y, Hao L, Xu L, Greenwald SE. Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors. Front Physiol 2020; 10:1563. [PMID: 32009976 PMCID: PMC6971205 DOI: 10.3389/fphys.2019.01563] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 12/12/2019] [Indexed: 11/16/2022] Open
Abstract
The accurate measurement of the arterial pulse wave is beneficial to clinical health assessment and is important for the effective diagnosis of many types of cardiovascular disease. A variety of sensors have been developed for the non-invasive detection of these waves, but the type of sensor has an impact on the measurement results. Therefore, it is necessary to compare and analyze the signals obtained under a range of conditions using various pulse sensors to aid in making an informed choice of the appropriate type. From the available types we have selected four: a piezoresistive strain gauge sensor (PESG) and a piezoelectric Millar tonometer (the former with the ability to measure contact force), a circular film acceleration sensor, and an optical reflection sensor. Pulse wave signals were recorded from the left radial, carotid, femoral, and digital arteries of 60 subjects using these four sensors. Their performance was evaluated by analyzing their susceptibilities to external factors (contact force, measuring site, and ambient light intensity) and by comparing their stability and reproducibility. Under medium contact force, the peak-to-peak amplitude of the signals was higher than that at high and low force levels and the variability of signal waveform was small. The optical sensor was susceptible to ambient light. Analysis of the intra-class correlation coefficients (ICCs) of the pulse wave parameters showed that the tonometer and accelerometer had good stability (ICC > 0.80), and the PESG and optical sensor had moderate stability (0.46 < ICC < 0.86). Intra-observer analysis showed that the tonometer and accelerometer had good reproducibility (ICC > 0.75) and the PESG and optical sensor had moderate reproducibility (0.42 < ICC < 0.91). Inter-observer analysis demonstrated that the accelerometer had good reproducibility (ICC > 0.85) and the three other sensors had moderate reproducibility (0.52 < ICC < 0.96). We conclude that the type of sensor and measurement site affect pulse wave characteristics and the careful selection of appropriate sensor and measurement site are required according to the research and clinical need. Moreover, the influence of external factors such as contact pressure and ambient light should be fully taken into account.
Collapse
Affiliation(s)
- Hongju Wang
- College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China
| | - Lu Wang
- School of Computer Science and Engineering, Northeastern University, Shenyang, China
| | - Nannan Sun
- College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China
| | - Yang Yao
- College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China
| | - Liling Hao
- College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China
| | - Lisheng Xu
- College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China
- Neusoft Research of Intelligent Healthcare Technology, Co. Ltd., Shenyang, China
| | - Stephen E. Greenwald
- Blizard Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| |
Collapse
|