1
|
Szabelski J, Karpiński R. Short-Term Hydrolytic Degradation of Mechanical Properties of Absorbable Surgical Sutures: A Comparative Study. J Funct Biomater 2024; 15:273. [PMID: 39330248 PMCID: PMC11432777 DOI: 10.3390/jfb15090273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 09/04/2024] [Accepted: 09/17/2024] [Indexed: 09/28/2024] Open
Abstract
Surgical sutures play a crucial role in wound closure, facilitating the tissue-healing process across various fields of medicine. The objective of this study was to analyse the impact of seasoning time during the initial days/weeks of seasoning in Ringer's solution on the mechanical properties of five commercial absorbable sutures: SafilQuick+®, Novosyn®, MonosynQuick®, Monosyn® and Monoplus®, each with different absorption periods. The results demonstrated that the SafilQuick+ and MonosynQuick sutures lost strength within 9-12 days, as evidenced by statistically significant changes in tensile strength. In contrast, the Novosyn and Monoplus sutures did not exhibit significant changes in strength during the study period. Statistical analysis confirmed significant differences in the behaviour of the individual sutures, highlighting the importance of selecting appropriate suture material in the context of the specific medical procedure.
Collapse
Affiliation(s)
- Jakub Szabelski
- Department of Computerization and Production Robotization, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
- I Department of Psychiatry, Psychotherapy, and Early Intervention, Medical University of Lublin, 20-439 Lublin, Poland
| |
Collapse
|
2
|
Ghandour S, Christie I, Öhman Mägi C, Persson C. Quasi-static and dynamic mechanical properties of a linoleic acid-modified, low-modulus bone cement for spinal applications. OPEN RESEARCH EUROPE 2024; 3:203. [PMID: 39185085 PMCID: PMC11344196 DOI: 10.12688/openreseurope.16683.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 05/15/2024] [Indexed: 08/27/2024]
Abstract
Background Polymethylmethacrylate (PMMA) bone cement is extensively used in spinal procedures such as vertebroplasty and kyphoplasty, while its use in percutaneous cement discoplasty (PCD) is not yet widely spread. A main issue for both application sites, vertebra and disc, is the mismatch in stiffness between cement and bone, potentially resulting in adjacent vertebral fractures and adjacent segment disease. Tailoring the cement modulus using additives is hence an interesting strategy. However, there is a lack of data on the tensile and tension-compression fatigue properties of these cements, relevant to the newly researched indication of PCD. Method A commercial PMMA cement (VS) was modified with 12%vol of linoleic acid (VSLA) and tested for quasi-static tensile properties. Additionally, tension-compression fatigue testing with amplitudes ranging from +/-5MPa to +/-7MPa and +/-9MPa was performed, and a Weibull three-parameter curve fit was used to calculate the fatigue parameters. Results Quasi-static testing revealed a significant reduction in VSLA's Young's Modulus (E=581.1±126.4MPa) compared to the original cement (E=1478.1±202.9MPa). Similarly, the ultimate tensile stress decreased from 36.6±1.5MPa to 11.6±0.8MPa. Thus, VSLA offers improved compatibility with trabecular bone properties. Fatigue testing of VSLA revealed that as the stress amplitude increased the Weibull mean number decreased from 3591 to 272 and 91 cycles, respectively. In contrast, the base VS cement reached run-out at the highest stress amplitude. However, the lowest stress amplitude used exceeds the pressures recorded in the disc in vivo, and VSLA displayed a similar fatigue life range to that of the annulus fibrosis tissue. Conclusions While the relevance of fully reversed tension-compression fatigue testing can be debated for predicting cement performance in certain spinal applications, the results of this study can serve as a benchmark for comparison of low-modulus cements for the spine. Further investigations are necessary to assess the clinical feasibility and effectiveness of these cements.
Collapse
Affiliation(s)
- Salim Ghandour
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden
| | - Iain Christie
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden
- Division of Applied Materials Science, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden
| | - Caroline Öhman Mägi
- Division of Applied Materials Science, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden
| |
Collapse
|
3
|
Wilczyński M, Bieniek M, Krakowski P, Karpiński R. Cemented vs. Cementless Fixation in Primary Knee Replacement: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1136. [PMID: 38473607 DOI: 10.3390/ma17051136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Revised: 02/13/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024]
Abstract
Knee osteoarthritis (OA) is one of the leading causes of disability around the globe. Osteoarthritis is mainly considered a disease affecting the elderly. However, more and more studies show that sports overuse, obesity, or congenital disorders can initiate a pathologic cascade that leads to OA changes in the younger population. Nevertheless, OA mostly affects the elderly, and with increasing life expectancy, the disease will develop in more and more individuals. To date, the golden standard in the treatment of the end-stage of the disease is total joint replacement (TJR), which restores painless knee motion and function. One of the weakest elements in TJR is its bonding with the bone, which can be achieved by bonding material, such as poly methyl-methacrylate (PMMA), or by cementless fixation supported by bone ingrowth onto the endoprosthesis surface. Each technique has its advantages; however, the most important factor is the revision rate and survivor time. In the past, numerous articles were published regarding TJR revision rate, but no consensus has been established yet. In this review, we focused on a comparison of cemented and cementless total knee replacement surgeries. We introduced PICO rules, including population, intervention, comparison and outcomes of TJR in a PubMed search. We identified 783 articles published between 2010 and 2023, out of which we included 14 in our review. Our review reveals that there is no universally prescribed approach to fixate knee prostheses. The determination of the most suitable method necessitates an individualized decision-making process involving the active participation and informed consent of each patient.
Collapse
Affiliation(s)
- Mikołaj Wilczyński
- Orthopaedic and Sports Traumatology Department, Carolina Medical Center, Pory 78, 02-757 Warsaw, Poland
| | - Michał Bieniek
- Orthopaedic and Sports Traumatology Department, Carolina Medical Center, Pory 78, 02-757 Warsaw, Poland
| | - Przemysław Krakowski
- Orthopaedic and Sports Traumatology Department, Carolina Medical Center, Pory 78, 02-757 Warsaw, Poland
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| |
Collapse
|
4
|
Humez M, Fröschen FS, Wirtz DC, Kühn KD. [The third-generation modern cementing technique in hip and knee arthroplasty]. ORTHOPADIE (HEIDELBERG, GERMANY) 2023; 52:968-980. [PMID: 37828239 DOI: 10.1007/s00132-023-04446-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 09/01/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND Implant loosening is the most common reason for revision surgery. OBJECTIVES Contribution of modern cementing technique to the long-term stability of an implant. METHODS Evaluation of the available evidence on modern cementing technique. RESULTS Modern cementing technique in hip arthroplasty is considered established and leads to better cementing results. In knee arthroplasty, there are also specific recommendations, including intensive cleaning of the bone bed, mixing of bone cement under vacuum and application of bone cement to the implant and the bone. CONCLUSIONS The use of modern cementing technique in hip and knee arthroplasty facilitates cementing, increases safety, and minimizes the risk of mechanical loosening.
Collapse
Affiliation(s)
- Martina Humez
- Heraeus Medical GmbH, Philipp-Reis-Str. 8/13, 61273, Wehrheim, Deutschland.
| | | | | | - Klaus-Dieter Kühn
- Heraeus Medical GmbH, Philipp-Reis-Str. 8/13, 61273, Wehrheim, Deutschland
- Department of Orthopaedics and Trauma, Medizinische Universität Graz, Graz, Österreich
| |
Collapse
|
5
|
Borkowski L, Jojczuk M, Belcarz A, Pawlowska-Olszewska M, Kruk-Bachonko J, Radzki R, Bienko M, Slowik T, Lübek T, Nogalski A, Ginalska G. Comparing the Healing Abilities of Fluorapatite and Hydroxyapatite Ceramics in Regenerating Bone Tissue: An In Vivo Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5992. [PMID: 37687681 PMCID: PMC10488477 DOI: 10.3390/ma16175992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 08/25/2023] [Accepted: 08/28/2023] [Indexed: 09/10/2023]
Abstract
Some reports in the literature show the advantages of fluoride-containing apatite ceramics over hydroxyapatite (HAP), at least in some aspects. While HAP has been used extensively in the treatment of bone defects, fluoridated apatite has hardly been tested in vivo. In order to verify the biological properties of fluoride-doped apatite and to assess its therapeutic potential, we synthesized fluorapatite (FAP) and applied it as a filling in bone defects of experimental animals (rabbits). The treatment effects were evaluated on extracted bones after 3 and 6 months from implantation using peripheral quantitative computed tomography (pQCT), dual-energy X-ray absorptiometry (DXA), radiography (X-ray) and histological staining. The study proved the integration between FAP and the bone tissue, thus indicating its stimulating effect on new bone formation and mineralization. The results achieved after 3 months of treatment were difficult to interpret unequivocally and suggested the transient delay in FAP integration of bone in comparison with HAP. The reasons for this phenomenon are unclear. Most likely, these differences between FAP and HAP resulted mainly from the different porosities, densities and ionic reactivity of the ceramics, which in our opinion affected their solubility, integration and degree of bone tissue resorption. However, it was shown that 6 months after implantation, similar level of bone defect regeneration was achieved for both FAP and HAP. In this article, we present our hypothesis concerning the basis of this phenomenon.
Collapse
Affiliation(s)
- Leszek Borkowski
- Chair and Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin, Poland
| | - Mariusz Jojczuk
- Chair and Department of Traumatology and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Anna Belcarz
- Chair and Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin, Poland
| | - Marta Pawlowska-Olszewska
- Department of Animal Physiology, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Akademicka St. 12, 20-950 Lublin, Poland
| | - Joanna Kruk-Bachonko
- 2nd Departament of Radiology, University Hospital of Lublin, Staszica 16, 20-081 Lublin, Poland
| | - Radoslaw Radzki
- Department of Animal Physiology, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Akademicka St. 12, 20-950 Lublin, Poland
| | - Marek Bienko
- Department of Animal Physiology, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Akademicka St. 12, 20-950 Lublin, Poland
| | - Tymoteusz Slowik
- Experimental Medicine Center, Medical University of Lublin, Jaczewskiego 8, 20-090 Lublin, Poland
| | - Tomasz Lübek
- Chair and Department of Traumatology and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Adam Nogalski
- Chair and Department of Traumatology and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Grazyna Ginalska
- Chair and Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin, Poland
| |
Collapse
|
6
|
Chaurasiya SP, Ghosh R. A new mathematical model of compressive stress-strain behaviour of low viscosity and high viscosity bone cement with different strain rates. Med Eng Phys 2023; 117:104001. [PMID: 37331754 DOI: 10.1016/j.medengphy.2023.104001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/23/2023] [Accepted: 05/27/2023] [Indexed: 06/20/2023]
Abstract
A new mathematical model of compressive stress-strain behaviour of low viscosity (LV) and high viscosity (HV) bone cement has been proposed to capture large uniaxial deformation under constant applied strain rate by incorporating three-term power law. The modeling capacity of the proposed model has been validated using uniaxial compressive test under eight different low strain rates ranging from 1.39 × 10-4 s-1 to 3.53 × 10-2 s-1 for low viscosity and high viscosity bone cement. The well agreement between the model and experimental response suggests that the proposed model can successfully predict rate dependent deformation behavior for Poly(methyl methacrylate) (PMMA) bone cement. Additionally, the proposed model was compared with the generalized Maxwell viscoelastic model and found to be in good agreement. The comparison of compressive responses over low strain rates for LV and HV bone cement reveals their rate-dependent compressive yield stress behaviour along with a higher value of compressive yield stress of LV bone cement compared to HV bone cement. For example, at the strain rate of 1.39 × 10-4 s-1 the mean value of compressive yield stress of LV bone cement was found to be 64.46 MPa, whereas for HV bone cement it was 54.00 MPa. Moreover, the modeling of experimental compressive yield stress with the Ree-Eyring molecular theory suggests that the variation of yield stress of PMMA bone cement can be predicted using two processes Ree-Eyring theory. The proposed constitutive model might be useful to characterize large deformation behaviour with high accuracy for PMMA bone cement. Finally, both variants of PMMA bone cement also exhibit ductile-like compressive behaviour below the strain rate of 2.1 × 10-2 s-1, whereas above this threshold strain rate, brittle-like compressive failure behavior is observed.
Collapse
Affiliation(s)
- Sonalal Prasad Chaurasiya
- Biomechanics Research Laboratory, School of Mechanical and Materials Engineering, Indian Institute of Technology Mandi, Kamand, Mandi, 175075, Himachal Pradesh, India
| | - Rajesh Ghosh
- Biomechanics Research Laboratory, School of Mechanical and Materials Engineering, Indian Institute of Technology Mandi, Kamand, Mandi, 175075, Himachal Pradesh, India.
| |
Collapse
|
7
|
Application of 3D Printing in Bone Grafts. Cells 2023; 12:cells12060859. [PMID: 36980200 PMCID: PMC10047278 DOI: 10.3390/cells12060859] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/05/2023] [Accepted: 03/08/2023] [Indexed: 03/12/2023] Open
Abstract
The application of 3D printing in bone grafts is gaining in importance and is becoming more and more popular. The choice of the method has a direct impact on the preparation of the patient for surgery, the probability of rejection of the transplant, and many other complications. The aim of the article is to discuss methods of bone grafting and to compare these methods. This review of literature is based on a selective literature search of the PubMed and Web of Science databases from 2001 to 2022 using the search terms “bone graft”, “bone transplant”, and “3D printing”. In addition, we also reviewed non-medical literature related to materials used for 3D printing. There are several methods of bone grafting, such as a demineralized bone matrix, cancellous allograft, nonvascular cortical allograft, osteoarticular allograft, osteochondral allograft, vascularized allograft, and an autogenic transplant using a bone substitute. Currently, autogenous grafting, which involves removing the patient’s bone from an area of low aesthetic importance, is referred to as the gold standard. 3D printing enables using a variety of materials. 3D technology is being applied to bone tissue engineering much more often. It allows for the treatment of bone defects thanks to the creation of a porous scaffold with adequate mechanical strength and favorable macro- and microstructures. Bone tissue engineering is an innovative approach that can be used to repair multiple bone defects in the process of transplantation. In this process, biomaterials are a very important factor in supporting regenerative cells and the regeneration of tissue. We have years of research ahead of us; however, it is certain that 3D printing is the future of transplant medicine.
Collapse
|
8
|
Effect of commonly used lavage solutions on the polymerization of bone cement. Orthop Traumatol Surg Res 2022; 108:103243. [PMID: 35158106 DOI: 10.1016/j.otsr.2022.103243] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/22/2021] [Accepted: 02/04/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Little is known about the impact irrigation solutions have on the material properties of cement used in hip and knee arthroplasty. We sought to compare the effect of three commonly used lavage solutions on cement polymerization. METHODS Ten groups were used for cure and mechanical testing: two cement controls, and eight cement groups mixed with test solutions. Test solutions included a commercially available benzalkonium chloride/citric acid solution (BCS), chlorhexidine gluconate (0.05%) (CHG), povidone-iodine 0.35%, and normal saline added at cement mixing onset. Cement dough-time, set-time, and compression testing were performed following The American Society for Testing and Materials guidelines. RESULTS Povidone-iodine had shorter dough-time (1min 34sec, sd 1min 5sec) versus controls (1min 56sec, sd 1min 35sec), p=0.0419. Cement exposed to all lavage samples had significantly reduced set-time. Compressive strength was reduced for all surgical lavages (p<0.001). Pairwise testing revealed that all lavage treatments reduced offset strength versus controls (p<0.001). CONCLUSION Bone cement exposed to lavage solutions during the cement mixing-phase showed accelerated set-times and decreased compressive strength. If bone is not dry, and cement has not finished mixing at the time of application, cement curing time may be shortened. Additionally, bone cement should reach dough phase prior to pre-closure surgical lavage. LEVEL OF EVIDENCE III; case control study.
Collapse
|
9
|
Szabelski J, Karpiński R, Krakowski P, Jojczuk M, Jonak J, Nogalski A. Analysis of the Effect of Component Ratio Imbalances on Selected Mechanical Properties of Seasoned, Medium Viscosity Bone Cements. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5577. [PMID: 36013714 PMCID: PMC9416016 DOI: 10.3390/ma15165577] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/05/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
The paper presents the results of experimental strength tests of specimens made of two commercially available bone cements subjected to compression, that is a typical variant of load of this material during use in the human body, after it has been used for implantation of prostheses or supplementation of bone defects. One of the factors analysed in detail was the duration of cement seasoning in Ringer's solution that simulates the aggressive environment of the human body and material degradation caused by it. The study also focused on the parameters of quantitative deviation from the recommended proportions of liquid (MMA monomer, accelerator and stabiliser) and powder (PMMA prepolymer and initiator) components, i.e., unintentional inaccuracy of component proportioning at the stage of cement mass preparation. Statistical analysis has shown the influence of these factors on the decrease in compressive strength of the cements studied, which may be of significant importance in operational practice.
Collapse
Affiliation(s)
- Jakub Szabelski
- Department of Computerization and Production Robotization, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Przemysław Krakowski
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
- Orthopaedic Department, Łęczna Hospital, Krasnystawska 52, 21-010 Leczna, Poland
| | - Mariusz Jojczuk
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Adam Nogalski
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| |
Collapse
|
10
|
Karpiński R, Szabelski J, Krakowski P, Jojczuk M, Jonak J, Nogalski A. Evaluation of the Effect of Selected Physiological Fluid Contaminants on the Mechanical Properties of Selected Medium-Viscosity PMMA Bone Cements. MATERIALS 2022; 15:ma15062197. [PMID: 35329650 PMCID: PMC8951357 DOI: 10.3390/ma15062197] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/10/2022] [Accepted: 03/15/2022] [Indexed: 02/06/2023]
Abstract
Revision surgeries several years after the implantation of the prosthesis are unfavorable from the patient’s point of view as they expose him to additional discomfort, to risk of complications and are expensive. One of the factors responsible for the aseptic loosening of the prosthesis is the gradual degradation of the cement material as a result of working under considerable loads, in an aggressive environment of the human body. Contaminants present in the surgical field may significantly affect the durability of the bone cement and, consequently, of the entire bone-cement-prosthesis system. The paper presents the results of an analysis of selected mechanical properties of two medium-viscosity bone cements DePuy CMW3 Gentamicin and Heraeus Palamed, for the samples contaminated with saline and blood in the range of 1–10%. The results obtained for compressive strength and modulus of elasticity were subjected to statistical analysis, which estimated the nature of changes in these parameters depending on the amount and type of contamination and their statistical significance.
Collapse
Affiliation(s)
- Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland;
- Correspondence: (R.K.); (J.S.)
| | - Jakub Szabelski
- Section of Biomedical Engineering, Department of Computerization and Production Robotization, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
- Correspondence: (R.K.); (J.S.)
| | - Przemysław Krakowski
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland; (P.K.); (M.J.); (A.N.)
- Orthopaedic Department, Łęczna Hospital, Krasnystawska 52, 21-010 Leczna, Poland
| | - Mariusz Jojczuk
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland; (P.K.); (M.J.); (A.N.)
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland;
| | - Adam Nogalski
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland; (P.K.); (M.J.); (A.N.)
| |
Collapse
|
11
|
Szabelski J, Karpiński R, Krakowski P, Jonak J. The Impact of Contaminating Poly (Methyl Methacrylate) (PMMA) Bone Cements on Their Compressive Strength. MATERIALS 2021; 14:ma14102555. [PMID: 34069222 PMCID: PMC8156221 DOI: 10.3390/ma14102555] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/13/2021] [Accepted: 05/13/2021] [Indexed: 11/21/2022]
Abstract
This study presents an analysis of the impact of doping bone cement with saline. The two-ingredient cement, made right before the surgery, is subject to various kinds of organic contaminants and liquids used in the operating area, such as saline used to cleanse or cool it, during the process of mounting the prosthesis or bone-filling procedures. The processes of experimental destructive testing and statistical analysis have shown that, depending on the degree of saline doping, the static compressive strength parameters may greatly improve (with a low degree of contamination) or significantly worsen (when the contamination degree is higher). The limit value of the degree of salt admixture was estimated (2%), with which no statistically significant differences were observed in the cement strength in relation to the strength of non-contaminated cement.
Collapse
Affiliation(s)
- Jakub Szabelski
- Section of Biomedical Engineering, Department of Computerization and Production Robotization, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
- Correspondence: (J.S.); (R.K.)
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland;
- Correspondence: (J.S.); (R.K.)
| | - Przemysław Krakowski
- Chair and Department of Traumatology and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland;
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland;
| |
Collapse
|
12
|
Effect of Physiological Saline Solution Contamination on Selected Mechanical Properties of Seasoned Acrylic Bone Cements of Medium and High Viscosity. MATERIALS 2020; 14:ma14010110. [PMID: 33383870 PMCID: PMC7796448 DOI: 10.3390/ma14010110] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 12/18/2020] [Accepted: 12/21/2020] [Indexed: 12/29/2022]
Abstract
Bone cements play a key role in present-day surgery, including the implantation of hip and knee joint endoprostheses. The correct and durable bonding of the prosthesis to the bone is affected by both the static strength characteristics determined in accordance with ISO 5833:2002 and the resistance to long-term exposure to an aggressive environment of the human body and the impurities that may be introduced into the cement during implementation. The study attempts to demonstrate statistically significant degradation of cement as a result of the seasoning of cement samples in Ringer’s solution with simultaneous contamination of the material with saline solution, which is usually present in the surgical field (e.g., during the fixing of endoprostheses). The results of statistical analysis showed the nature of changes in compressive strength and microhardness due to seasoning time and degree of contamination.
Collapse
|
13
|
Use of Deep Learning Networks and Statistical Modeling to Predict Changes in Mechanical Parameters of Contaminated Bone Cements. MATERIALS 2020; 13:ma13235419. [PMID: 33260793 PMCID: PMC7731130 DOI: 10.3390/ma13235419] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 11/25/2020] [Accepted: 11/26/2020] [Indexed: 12/14/2022]
Abstract
The purpose of the study was to test the usefulness of deep learning artificial neural networks and statistical modeling in predicting the strength of bone cements with defects. The defects are related to the introduction of admixtures, such as blood or saline, as contaminants into the cement at the preparation stage. Due to the wide range of applications of deep learning, among others in speech recognition, bioinformation processing, and medication design, the extent was checked to which it is possible to obtain information related to the prediction of the compressive strength of bone cements. Development and improvement of deep learning network (DLN) algorithms and statistical modeling in the analysis of changes in the mechanical parameters of the tested materials will enable determining an acceptable margin of error during surgery or cement preparation in relation to the expected strength of the material used to fill bone cavities. The use of the abovementioned computer methods may, therefore, play a significant role in the initial qualitative assessment of the effects of procedures and, thus, mitigation of errors resulting in failure to maintain the required mechanical parameters and patient dissatisfaction.
Collapse
|