Martí-Vigil J, Casamitjana J, Marimon X, Cerrolaza M, Medina-Gálvez R, Cantó-Navés O, Ferrer M, Cabratosa-Termes J. Impact Testing in Implant-Supported Prostheses and Natural Teeth: A Systematic Review of Properties and Performance. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4040. [PMID: 39203218 PMCID: PMC11356274 DOI: 10.3390/ma17164040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 08/04/2024] [Accepted: 08/12/2024] [Indexed: 09/03/2024]
Abstract
Dental implants offer an effective solution for partial and total edentulism, but mechanical and biological complications exist. Furthermore, high occlusal loads challenge implants and lead to potential failures. This review focuses on impact testing in contrast to incremental and static tests, an underexplored aspect of assessing daily loads on implants, bringing to light potential complications. The review examines studies employing impact forces to assess implant-supported prostheses and natural teeth properties, highlighting their significance in dental research. A systematic search following PRISMA guidelines identified 21 relevant articles out of 224, emphasizing studies employing impact forces to evaluate various aspects of dental implant treatments. The diverse applications of impact forces in dental research were categorized into tooth structure, restorative materials, interface evaluation, implant properties, and finite element models. Some studies showed the significance of impact forces in assessing stress distribution, shock absorption, and biomechanical response. Impact testing is a critical tool for understanding the daily forces on implants. Despite diverse experimental approaches, a lack of standardized protocols complicates the systematization of the results and, therefore, the conclusions. This review highlights the need for consistent methodologies in impact testing studies for future research on implant-supported prostheses.
Collapse
Affiliation(s)
- Jordi Martí-Vigil
- School of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain; (J.M.-V.); (R.M.-G.); (J.C.-T.)
| | | | - Xavier Marimon
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain
| | - Miguel Cerrolaza
- School of Engineering, Science & Technology, Valencian International University, 46002 Valencia, Spain;
| | - Raul Medina-Gálvez
- School of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain; (J.M.-V.); (R.M.-G.); (J.C.-T.)
| | - Oriol Cantó-Navés
- School of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain; (J.M.-V.); (R.M.-G.); (J.C.-T.)
| | - Miquel Ferrer
- Department of Strength of Materials and Structural Engineering, Universitat Politècnica de Catalunya (UPC-BarcelonaTECH), 08034 Barcelona, Spain;
| | - Josep Cabratosa-Termes
- School of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain; (J.M.-V.); (R.M.-G.); (J.C.-T.)
| |
Collapse
|
2
|
Kohal RJ, Riesterer E, Vach K, Patzelt SBM, Iveković A, Einfalt L, Kocjan A, Hillebrecht AL. Fracture Resistance of a Bone-Level Two-Piece Zirconia Oral Implant System-The Influence of Artificial Loading and Hydrothermal Aging. J Funct Biomater 2024; 15:122. [PMID: 38786633 PMCID: PMC11122605 DOI: 10.3390/jfb15050122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/24/2024] [Accepted: 05/04/2024] [Indexed: 05/25/2024] Open
Abstract
Preclinical and clinical research on two-piece zirconia implants are warranted. Therefore, we evaluated the in vitro fracture resistance of such a zirconia oral implant system. The present study comprised 32 two-piece zirconia implants and abutments attached to the implants using a titanium (n = 16) or a zirconia abutment screw (n = 16). Both groups were subdivided (n = 8): group T-0 comprised implants with a titanium abutment screw and no artificial loading; group T-HL was the titanium screw group exposed to hydro-thermomechanical loading in a chewing simulator; group Z-0 was the zirconia abutment screw group with no artificial loading; and group Z-HL comprised the zirconia screw group with hydro-thermomechanical loading. Groups T-HL and Z-HL were loaded with 98 N and aged in 85 °C hot water for 107 chewing cycles. All samples were loaded to fracture. Kruskal-Wallis tests were executed to assess the loading/bending moment group differences. The significance level was established at a probability of 0.05. During the artificial loading, there was a single occurrence of an implant fracture. The mean fracture resistances measured in a universal testing machine were 749 N for group T-0, 828 N for group Z-0, 652 N for group T-HL, and 826 N for group Z-HL. The corresponding bending moments were as follows: group T-0, 411 Ncm; group Z-0, 452 Ncm; group T-HL, 356 Ncm; and group Z-HL, 456 Ncm. There were no statistically significant differences found between the experimental groups. Therefore, the conclusion was that loading and aging did not diminish the fracture resistance of the evaluated implant system.
Collapse
Affiliation(s)
- Ralf J. Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| | - Ellen Riesterer
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| | - Kirstin Vach
- Medical Center—University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany;
| | - Sebastian B. M. Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
- Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany
| | - Aljaž Iveković
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
| | - Lara Einfalt
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
- Jožef Stefan International Postgraduate School, Jamova 39, 1000 Ljubljana, Slovenia
| | - Andraž Kocjan
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
| | - Anna-Lena Hillebrecht
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| |
Collapse
|
3
|
Gul A, Papia E, Naimi-Akbar A, Ruud A, Vult von Steyern P. Zirconia dental implants; the relationship between design and clinical outcome: A systematic review. J Dent 2024; 143:104903. [PMID: 38437977 DOI: 10.1016/j.jdent.2024.104903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 02/09/2024] [Accepted: 02/26/2024] [Indexed: 03/06/2024] Open
Abstract
OBJECTIVE To evaluate the clinical outcome of different designs of zirconia dental implants. DATA This systematic review adhered to the PRISMA checklist and followed the PICO framework. The protocol is registered in PROSPERO (CRD42022337228). SOURCES The search was conducted in March 2023 through four databases (PubMed, Web of Science, Cochrane Library, and Google Scholar) along with a search of references in the related reviews. Three authors reviewed on title, and abstract level and analysed the risk of bias, and all authors reviewed on a full-text level. STUDY SELECTION Clinical studies excluding case reports for patients treated with different designs of zirconia dental implants were included. From a total of 2728 titles, 71 full-text studies were screened, and 27 studies were included to assess the risk of bias (ROBINS-I tool) and data extraction. After quality assessment, four studies were included, and the remaining 23 excluded studies were narratively described. RESULT The included prospective studies with moderate risk of bias reported success and survival rates of one-piece implants that ranged between 95 and 98.4 % with no difference between different lengths and diameters. The acid-etched roughened surface showed higher clinical outcomes compared to other surface roughness designs. CONCLUSION Promising 5-year clinical outcomes were found for one-piece zirconia implants with no difference between different diameters and lengths. Concerning surface roughness, better outcomes were found when using the acid-etched implant surface. However, due to the limited available studies, further high-quality clinical studies comparing zirconia one-piece and two-piece implants with different diameters, lengths, and surface roughness are needed. CLINICAL SIGNIFICANCE Based on this systematic review, under suitable clinical situations, the one-piece zirconia implants with diameters of 4.0 mm, 4.5 mm, or 5.5 mm and lengths of 8 mm, 10 mm, 12 mm, or 14 mm have similar promising clinical outcomes. Additionally, the acid-etched roughened implant surface may be preferable.
Collapse
Affiliation(s)
- Abdulaziz Gul
- Department of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, Sweden; Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia.
| | - Evaggelia Papia
- Department of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Aron Naimi-Akbar
- Health Technology Assessment-Odontology (HTA-O), Faculty of Odontology, Malmö University, Malmö, Sweden; Department of Oral and Maxillofacial Surgery and Oral Medicine, Division 2, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Amund Ruud
- Nordic Institute of Dental Materials, NIOM, Oslo, Norway
| | - Per Vult von Steyern
- Department of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, Sweden; Nordic Institute of Dental Materials, NIOM, Oslo, Norway
| |
Collapse
|
4
|
Mohseni P, Soufi A, Chrcanovic BR. Clinical outcomes of zirconia implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 28:15. [PMID: 38135804 PMCID: PMC10746607 DOI: 10.1007/s00784-023-05401-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. METHODS An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done. RESULTS Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up. CONCLUSION Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055). CLINICAL RELEVANCE The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Collapse
Affiliation(s)
| | - Ahmad Soufi
- Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Bruno Ramos Chrcanovic
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21, Malmö, Sweden.
| |
Collapse
|
5
|
Kohal RJ, Schikofski T, Adolfsson E, Vach K, Patzelt SBM, Nold J, Wemken G. Fracture Resistance of a Two-Piece Zirconia Implant System after Artificial Loading and/or Hydrothermal Aging-An In Vitro Investigation. J Funct Biomater 2023; 14:567. [PMID: 38132821 PMCID: PMC10743638 DOI: 10.3390/jfb14120567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/29/2023] [Accepted: 12/11/2023] [Indexed: 12/23/2023] Open
Abstract
The purpose of the present study was to assess the fracture resistance of a two-piece alumina-toughened zirconia implant system with a carbon-reinforced PEEK abutment screw. METHODS Thirty-two implants with screw-retained zirconia abutments were divided into four groups of eight samples each. Group 0 (control group) was neither loaded nor aged in a chewing simulator; group H was hydrothermally aged; group L was loaded with 98 N; and group HL was subjected to both hydrothermal aging and loading in a chewing simulator. One sample of each group was evaluated for t-m phase transformation, and the others were loaded until fracture. A one-way ANOVA was applied to evaluate differences between the groups. RESULTS No implant fracture occurred during the artificial chewing simulation. Furthermore, there were no statistically significant differences (p > 0.05) between the groups in terms of fracture resistance (group 0: 783 ± 43 N; group H: 742 ± 43 N; group L: 757 ± 86 N; group HL: 740 ± 43 N) and bending moment (group 0: 433 ± 26 Ncm; group H: 413 ± 23 Ncm; group L: 422 ± 49 Ncm; group HL: 408 ± 27 Ncm). CONCLUSIONS Within the limitations of the present investigation, it can be concluded that artificial loading and hydrothermal aging do not reduce the fracture resistance of the investigated implant system.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Tim Schikofski
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Erik Adolfsson
- RISE Research Institutes of Sweden, 431 53 Mölndal, Sweden;
| | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany;
| | - Sebastian Berthold Maximilian Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
- Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany
| | - Julian Nold
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Gregor Wemken
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| |
Collapse
|
6
|
Khaohoen A, Sornsuwan T, Chaijareenont P, Poovarodom P, Rungsiyakull C, Rungsiyakull P. Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review. J Clin Med 2023; 12:6924. [PMID: 37959389 PMCID: PMC10649288 DOI: 10.3390/jcm12216924] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/15/2023] Open
Abstract
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting's bone state.
Collapse
Affiliation(s)
- Angkoon Khaohoen
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Tanapon Sornsuwan
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok 65000, Thailand;
| | - Pisaisit Chaijareenont
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| |
Collapse
|
7
|
Helal E, Gierthmuehlen PC, Bonfante EA, Campos TMB, Prott LS, Langner R, Spitznagel FA. Influence of straight versus angulated screw channel titanium bases on failure loads of two-piece ceramic and titanium implants restored with screw-retained monolithic crowns: An in-vitro study. Clin Oral Implants Res 2023; 34:1217-1229. [PMID: 37565379 DOI: 10.1111/clr.14157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 07/13/2023] [Accepted: 07/25/2023] [Indexed: 08/12/2023]
Abstract
OBJECTIVE To analyze the influence of titanium-base (straight [SSC]/angulated-screw-channel [ASC]) on failure-loads and bending-moments of two-piece ceramic and titanium-zirconium implants restored with monolithic-zirconia crowns after fatigue. MATERIALS AND METHODS Thirty-two anterior monolithic-screw-retained zirconia crowns were divided into four groups (n = 8/group) according to the factors: (1) type of implant material: two-piece titanium-zirconium implant (Ti-Zr; control-group) versus two-piece ceramic implant (CI; test-group) and (2) type of titanium-base: SSC (0° angle) versus ASC (25°). An intact implant was used for field emission gun-scanning electronic microscopy (FEG-SEM) characterization and Raman spectroscopy for phase analyses and residual stress quantification. All samples were exposed to fatigue with thermodynamic loading (1.2-million-cycles, 49 N, 1.6 Hz, 5-55°C) at a 30° angle. Surviving specimens were loaded until failure (SLF) and bending moments were recorded. Failed samples were examined using light microscope and SEM. Statistical analyses included ANOVA and Mann-Whitney U-test. RESULTS Raman-spectroscopy revealed the presence of residual compressive stresses. FEG-SEM revealed a roughened surface between threads and polished surface at the cervical-collar of the ceramic implant. All samples survived fatigue and were free of complications. Mean bending-moments (±SD) were: Ti-Zr-0: 241 ± 45 N cm, Ti-Zr-25: 303 ± 86 N cm, CI-0: 326 ± 58 N cm, CI-25: 434 ± 71 N cm. Titanium-base and implant-material had significant effects in favor of ASC titanium bases (p = .001) and ceramic-implants (p < .001). Failure analysis after SLF revealed severe fractures in ceramic implants, whereas titanium implants were restricted to plastic deformation. CONCLUSIONS Ceramic and titanium implants exhibited high reliability after fatigue, with no failures. From a mechanical perspective, titanium bases with ASC can be recommended for both ceramic and titanium implants and are safe for clinical application.
Collapse
Affiliation(s)
- E Helal
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - P C Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - E A Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - T M B Campos
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - L S Prott
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - R Langner
- Institute of Systems Neuroscience, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- Institute of Neuroscience and Medicine, Brain and Behavior (INM-7), Research Center Jülich, Jülich, Germany
| | - F A Spitznagel
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
8
|
Kongkiatkamon S, Rokaya D, Kengtanyakich S, Peampring C. Current classification of zirconia in dentistry: an updated review. PeerJ 2023; 11:e15669. [PMID: 37465158 PMCID: PMC10351515 DOI: 10.7717/peerj.15669] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/09/2023] [Indexed: 07/20/2023] Open
Abstract
Zirconia, a crystalline oxide of zirconium, holds good mechanical, optical, and biological properties. The metal-free restorations, mostly consisting of all-ceramic/zirconia restorations, are becoming popular restorative materials in restorative and prosthetic dentistry choices for aesthetic and biological reasons. Dental zirconia has increased over the past years producing wide varieties of zirconia for prosthetic restorations in dentistry. At present, literature is lacking on the recent zirconia biomaterials in dentistry. Currently, no article has the latest information on the various zirconia biomaterials in dentistry. Hence, the aim of this article is to present an overview of recent dental zirconia biomaterials and tends to classify the recent zirconia biomaterials in dentistry. This article is useful for dentists, dental technicians, prosthodontists, academicians, and researchers in the field of dental zirconia.
Collapse
Affiliation(s)
- Suchada Kongkiatkamon
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Dinesh Rokaya
- Faculty of Dentistry, Zarqa University, Zarqa, Jordan
| | - Santiphab Kengtanyakich
- Prosthodontic Section, Department of Restorative Dentistry, Naresuan University, Phitsanulok, Thailand
| | - Chaimongkon Peampring
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
9
|
Thu MK, Kang YS, Kwak JM, Jo YH, Han JS, Yeo ISL. Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants. Sci Rep 2023; 13:11142. [PMID: 37429939 DOI: 10.1038/s41598-023-38432-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 07/07/2023] [Indexed: 07/12/2023] Open
Abstract
The aim of this study was to investigate the surface characteristics and evaluate the bone-implant interfaces of injection molded zirconia implants with or without surface treatment and compare them with those of conventional titanium implants. Four different zirconia and titanium implant groups (n = 14 for each group) were prepared: injection-molded zirconia implants without surface treatment (IM ZrO2); injection-molded zirconia implants with surface treatment via sandblasting (IM ZrO2-S); turned titanium implants (Ti-turned); and titanium implants with surface treatments via sandblasting with large-grit particles and acid-etching (Ti-SLA). Scanning electron microscopy, confocal laser scanning microscopy, and energy dispersive spectroscopy were used to assess the surface characteristics of the implant specimens. Eight rabbits were used, and four implants from each group were placed into the tibiae of each rabbit. Bone-to-implant contact (BIC) and bone area (BA) were measured to evaluate the bone response after 10-day and 28-day healing periods. One-way analysis of variance with Tukey's pairwise comparison was used to find any significant differences. The significance level was set at α = 0.05. Surface physical analysis showed that Ti-SLA had the highest surface roughness, followed by IM ZrO2-S, IM ZrO2, and Ti-turned. There were no statistically significant differences (p > 0.05) in BIC and BA among the different groups according to the histomorphometric analysis. This study suggests that injection-molded zirconia implants are reliable and predictable alternatives to titanium implants for future clinical applications.
Collapse
Affiliation(s)
- Myint Kyaw Thu
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Young Suk Kang
- 618th Medical Company (Dental Area Support)/Dental Health Activity-Korea, Camp Humphreys, APO, AP, 96297, USA
| | - Jeong Min Kwak
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Ye-Hyeon Jo
- Dental Research Institute, Seoul National University, Seoul, 03080, Korea
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea.
| |
Collapse
|
10
|
Kohal RJ, Burkhardt F, Chevalier J, Patzelt SBM, Butz F. One-Piece Zirconia Oral Implants for Single Tooth Replacement: Five-Year Results from a Prospective Cohort Study. J Funct Biomater 2023; 14:jfb14020116. [PMID: 36826915 PMCID: PMC9964460 DOI: 10.3390/jfb14020116] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/06/2023] [Accepted: 02/15/2023] [Indexed: 02/22/2023] Open
Abstract
The intention of this 5-year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one-piece zirconia implant system for single tooth replacement. Sixty-five patients received a total of 66 single-tooth implants. All implants immediately received temporary restorations and were finally restored with all-ceramic crowns. Follow-ups were performed at the prosthetic delivery, after 1, 3, and 5 years. Peri-implant and dental soft-tissue parameters were evaluated and patient-reported outcomes recorded. To monitor peri-implant bone remodelling, standardised radiographs were taken at the implant insertion and at the 1-, 3-, and 5-year follow-ups. In the course of 5 years, 14 implants were lost, resulting in a cumulative implant survival rate of 78.2%. The mean marginal bone loss from the implant insertion to the 5-year follow-up amounted to 1.12 mm. Probing depth, clinical attachment level, bleeding, and plaque index increased over time. In 91.5% of the implants, the papilla index showed levels of 1 or 2, respectively. At the end of the study, the patient satisfaction was higher compared to the pre-treatment measurements. Due to the low survival rate after five years and the noticeably high frequency of advanced bone loss observed in this study, the implant has not met the launch criteria, as it would have not been recommended for routine clinical use.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Jerome Chevalier
- INSA-Lyon, MATEIS Laboratory, University of Lyon, UMR CNRS 5510, 20 Avenue Albert Einstein, CEDEX, 69621 Villeurbanne, France
| | - Sebastian Berthold Maximilian Patzelt
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Frank Butz
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Belchenstrasse 6a, 79189 Bad Krozingen, Germany
- Correspondence:
| |
Collapse
|
11
|
Kohal RJ, von Schierholz C, Nold J, Spies BC, Adolfsson E, Vach K, Burkhardt F. Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment. Clin Oral Implants Res 2023; 34:105-115. [PMID: 36444693 DOI: 10.1111/clr.14022] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/31/2022] [Accepted: 11/22/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging. METHODS Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 107 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT). One group remained untreated (group 0). A sample from each group was cross-sectioned and examined by scanning electron microscopy for possible crystal phase transformation. The remaining samples were then loaded to fracture in a static loading test. A one-way ANOVA was used for statistical analyses. RESULTS During dynamic loading, three implants of group DL and six implants of group DL/HT fractured at a load of 98 N. The fracture strength of group DL/HT (108 ± 141 Ncm) was significantly reduced compared to the other groups (group 0: 342 ± 36 Ncm; HT: 363 ± 49 Ncm; DL: 264 ± 198 Ncm) (p < .05). Fractures from group 0 and HT occurred at both implant and abutment level, whereas implants from group DL and DL/HT fractured only at implant level. A shallow monoclinic transformation zone of approximately 2 μm was observed following hydrothermal treatment. CONCLUSIONS Within the limitations of this study, it can be concluded that dynamic loading and the combination of loading and aging reduced the fracture strength of the implant abutment combination. Hydrothermal treatment caused a shallow transformation zone which had no influence on the fracture strength.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Christopher von Schierholz
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Julian Nold
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | | | - Kirstin Vach
- Faculty of Medicine, Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, University of Freiburg, Freiburg, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
12
|
Bonyatpour M, Giti R, Erfanian B. Implant angulation and fracture resistance of one-piece screw-retained hybrid monolithic zirconia ceramic restorations. PLoS One 2023; 18:e0280816. [PMID: 36689439 PMCID: PMC9870147 DOI: 10.1371/journal.pone.0280816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 01/09/2023] [Indexed: 01/24/2023] Open
Abstract
OBJECTIVE This study aimed to investigate the fracture resistance of one-piece screw-retained hybrid monolithic zirconia ceramic restorations in different implant angulations. MATERIALS AND METHODS Three implant fixtures were embedded in acrylic resin blocks with 0°, 15°, and 25° angulations. For each group of implant angulations, 11 screw-retained one-piece monolithic zirconia restorations were made and bonded to the titanium inserts with a dual-cure self-adhesive resin. The complexes were screwed to the implant fixtures with titanium screws. The samples were thermocycled, subjected to compressive load, and fracture modes were recorded. One-way ANOVA and post hoc Tukey's test were used for statistical analyses (α = 0.05). RESULTS One-way ANOVA showed the fracture resistance to be significanltly different among the study groups (P = 0.036). The 15° group was significantly more resistant than 0° (P = 0.031). However, the 25° group was not significantly different from the 15° (P = 0.203) and 0° groups (P = 0.624). Fractures occurred only on the restorations, not at the screw levels. CONCLUSIONS Tilting the implant up to 15° improves the fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations; however, increasing the tilt to 25° would not yield restorations with significantly better fracture strength than the straight implants. Accordingly, when angulated implants are indicated in the esthetic zones, one-piece screw-retained hybrid monolithic zirconia ceramic restorations can be used with acceptable fracture strength.
Collapse
Affiliation(s)
- Milad Bonyatpour
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Rashin Giti
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Behrad Erfanian
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| |
Collapse
|
13
|
Kohal RJ, Vach K, Butz F, Spies BC, Patzelt SBM, Burkhardt F. One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series. J Funct Biomater 2023; 14:jfb14010045. [PMID: 36662092 PMCID: PMC9864364 DOI: 10.3390/jfb14010045] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 01/15/2023] Open
Abstract
The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of ≤2 mm) and success grade II of 61% (bone loss of ≤3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Correspondence:
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Zinkmattenstr. 6a, 79108 Freiburg, Germany
| | - Frank Butz
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Belchenstr. 6a, 79189 Bad Krozingen, Germany
| | - Benedikt Christopher Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sebastian Berthold Maximilian Patzelt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| |
Collapse
|
14
|
Zhang F, Monzavi M, Li M, Čokić S, Manesh A, Nowzari H, Vleugels J, Van Meerbeek B. Fracture analysis of one/two-piece clinically failed zirconia dental implants. Dent Mater 2022; 38:1633-1647. [PMID: 36064469 DOI: 10.1016/j.dental.2022.08.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/13/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Analyzing factors that may have led to fracture of zirconia implants by macro/micro-fractography. METHODS Six one-piece and ten two-piece full-ceramic zirconia implants from two manufacturers, Z-Systems and CeraRoot, were retrieved after clinical failure. The time-to-failure ranged from 3 to 49 months. Optical and scanning electron microscopy (SEM) were used to analyze the fracture planes at the macro- and microscopic level. Treatment planning, surgical protocol, fracture-origin location and characteristic fracture features were assessed. RESULTS The fracture of all implants seemed to have been primarily due to overload in bending mode, while the fracture-initiation sites varied for the one- and two-piece implants. The fracture of all one-piece implants originated in the constriction region between two threads in the endosseous implant part. For two-piece implants, the abutment neck, internal abutment-implant connections and inner threads were found to be the main fracture-initiation sites. Surface defects at the root area for one-piece implants and damages at the abutment surface for two-piece implants were connected to the fracture origins. Importantly, the clinical failures of implants were often found to result from combined effects related to patient aspects, treatment planning/protocols, a high bending moment at the weakest link, implant-surface conditions and specific implant designs. SIGNIFICANCE This study provided information to be considered for future optimization of treatment planning and the surgical protocol for zirconia implants. Optimization of the surface conditions and the zirconia-starting powder were also suggested.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`; KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium.
| | - Mona Monzavi
- Periodontics and Ceramic Implantology (private Practice), 1401N Tustin Ave Suite #345, Santa Ana, CA 92705, USA
| | - Maoyin Li
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Stevan Čokić
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| | - Al Manesh
- Mission Dental Implant Center (private Practice), 26800 Crown Valley Pkwy Ste 425, Mission Viejo, CA 92691, USA
| | - Hessam Nowzari
- Periodontics and Implant Dentistry (private practice), 120 S Spalding Dr #201, Beverlyhills, CA 90210, USA
| | - Jef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| |
Collapse
|
15
|
Zhang F, Spies BC, Willems E, Inokoshi M, Wesemann C, Cokic SM, Hache B, Kohal RJ, Altmann B, Vleugels J, Van Meerbeek B, Rabel K. 3D printed zirconia dental implants with integrated directional surface pores combine mechanical strength with favorable osteoblast response. Acta Biomater 2022; 150:427-441. [PMID: 35902036 DOI: 10.1016/j.actbio.2022.07.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/25/2022] [Accepted: 07/19/2022] [Indexed: 11/01/2022]
Abstract
Dental implants need to combine mechanical strength with promoted osseointegration. Currently used subtractive manufacturing techniques require a multi-step process to obtain a rough surface topography that stimulates osseointegration. Advantageously, additive manufacturing (AM) enables direct implant shaping with unique geometries and surface topographies. In this study, zirconia implants with integrated lamellar surface topography were additively manufactured by nano-particle ink-jetting. The ISO-14801 fracture load of as-sintered implants (516±39 N) resisted fatigue in 5-55°C water thermo-cycling (631±134 N). Remarkably, simultaneous mechanical fatigue and hydrothermal aging at 90°C significantly increased the implant strength to 909±280 N due to compressive stress generated at the seamless transition of the 30-40 µm thick, rough and porous surface layer to the dense implant core. This unique surface structure induced an elongated osteoblast morphology with uniform cell orientation and allowed for osteoblast proliferation, long-term attachment and matrix mineralization. In conclusion, the developed AM zirconia implants not only provided high long-term mechanical resistance thanks to the dense core along with compressive stress induced at the transition zone, but also generated a favorable osteoblast response owing to the integrated directional surface pores. STATEMENT OF SIGNIFICANCE: : Zirconia ceramics are becoming the material of choice for metal-free dental implants, however significant efforts are required to obtain a rough/porous surface for enhanced osseointegration, along with the risk of surface delamination and/or microstructure variation. In this study, we addressed the challenge by additively manufacturing implants that seamlessly combine dense core with a porous surface layer. For the first time, a unique surface with a directional lamellar pore morphology was additively obtained. This AM implant also provided strength as strong as conventionally manufactured zirconia implants before and after long-term fatigue. Favorable osteoblast response was proved by in-vitro cell investigation. This work demonstrated the opportunity to AM fabricate novel ceramic implants that can simultaneously meet the mechanical and biological functionality requirements.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium.
| | - Benedikt C Spies
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Evita Willems
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Masanao Inokoshi
- Tokyo Medical and Dental University, Graduate School of Medical and Dental Sciences, Department of Gerodontology and Oral Rehabilitation, Tokyo, Japan
| | - Christian Wesemann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Berlin, Germany
| | - Stevan M Cokic
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Benedikt Hache
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Ralf J Kohal
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Brigitte Altmann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Kerstin Rabel
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| |
Collapse
|
16
|
Atalay P, Öztaş DD. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments. J ESTHET RESTOR DENT 2022; 34:1060-1067. [PMID: 35855644 DOI: 10.1111/jerd.12944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Zirconia implants are assumed to satisfy the esthetic requirements that titanium implants cannot meet, however, there are not enough studies in the literature about narrow-diameter and angled zirconia implants that can be preferred especially in the anterior region. This in vitro study aimed to evaluate the fatigue resistance and fracture strength of narrow-diameter zirconia implants with angled abutments. MATERIALS AND METHODS Forty-eight one-piece experimental zirconia implants and monolithic zirconia crowns were produced from 3-YTZP blanks. The implant diameters (3.0 or 3.7 mm) and the restoration types were determined according to three intraoral regions (upper central incisors, lower central incisors, and upper canine), and abutments were designed as straight or 15° angled. The samples were subjected to chewing simulation corresponding to 5 years of clinical performance and then the static loading test. The survival rates of groups were measured by the Kaplan-Meier log-rank test, and the fracture load values were estimated by using Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS All 3.0 mm diameter implants failed the fatigue test. The fatigue resistance of the implants with angled abutments was significantly lower than the straight abutments, and different crown designs were found to affect survival rates significantly. The fracture strengths of the surviving groups were above the maximum physiological chewing forces, and the differences were not significant. CONCLUSIONS The implant diameter, abutment angle, and restoration type have a significant effect on the fatigue behavior of zirconia implants. CLINICAL SIGNIFICANCE The fracture strengths of the one-piece zirconia implants with a 3.7 mm diameter and a 15° abutment angle are above the chewing forces for the anterior intraoral region.
Collapse
Affiliation(s)
- Pelin Atalay
- Department of Prosthodontics, Faculty of Dentistry, University of Niğde Ömer Halisdemir, Niğde, Turkey
| | - Doğan Derya Öztaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
17
|
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series-Long-Term Results after 11 Years of Clinical Function. MATERIALS 2021; 14:ma14226738. [PMID: 34832139 PMCID: PMC8621133 DOI: 10.3390/ma14226738] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 11/04/2021] [Accepted: 11/05/2021] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The aim of this prospective case series was to evaluate single-piece zirconia implants restored with lithium disilicate CAD/CAM crowns through a long-term follow-up. METHODS In this trial, 20 one-piece zirconia implants were placed in 20 patients. Implants were restored (i) immediately with lithium disilicate CAD/CAM provisionals, and (ii) permanently four months after surgery. Patients were followed for 11 years. Clinical parameters and radiological measurements of the zirconia implants were assessed. For the statistical analysis, paired t-test was applied. RESULTS Four implants were counted as implant failure due to the loss of implant stability, resulting in a Kaplan-Meier survival rate of 80% up to 11 years. The mean bleeding on probing values were 19.1% (SD ± 13.1) and 18.2% (SD ± 17.6) 96 and 11 years after implant placement, respectively. The plaque index revealed a significant decrease over time (p < 0.001) with a value between 25.9% (SD ± 5.7) and 12.6% (SD ± 10.0) at baseline and 11-years follow-up respectively. The marginal bone level revealed a significant decrease 4, 8, and 11 years after implant insertion (p = 0.001, p = 0.019, and p = 0.027, respectively). CONCLUSIONS Immediately loaded zirconia single-piece implants showed a suitable success rate in clinical and radiographic outcomes.
Collapse
|
18
|
Hanes B, Feitosa S, Phasuk K, Levon JA, Morton D, Lin WS. Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants. J Prosthodont 2021; 31:441-446. [PMID: 34632673 DOI: 10.1111/jopr.13440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/03/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To evaluate the fracture resistance behaviors of titanium-zirconium, one-piece zirconia, and two-piece zirconia implants restored by zirconia crowns and different combinations of abutment materials (zirconia and titanium) and retention modes (cement-retained and screw-retained zirconia crowns). MATERIAL AND METHODS Three research groups (n=12) were evaluated according to combinations of abutment material, retention mode, and implant type. In the control group (TTC), titanium-zirconium implants (∅ 4.1 mm RN, 12 mm, Roxolid; Straumann USA, Andover, MA) and prefabricated titanium abutments (RN synOcta Cementable Abutment, H 5.5 mm; Straumann USA) were used to support cement-retained zirconia crowns. In the second group (ZZC), one-piece zirconia implants (PURE Ceramic Implant Monotype, ∅ 4.1 mm RD, 12 mm, AH 5.5 mm; Straumann USA) were used to support cement-retained zirconia crowns. In the third group (ZTS), two-piece zirconia implants (PURE Ceramic Implant, ∅ 4.1 mm RD, 12 mm) and prefabricated titanium abutments (CI RD PUREbase Abutment, H 5.5 mm) were used to support screw-retained zirconia crowns. All zirconia crowns were manufactured in the same anatomic contour with a 5-axis dental mill and blended 3 and 5 mol% yttria-stabilized zirconia (LayZir A2). Implants were inserted into specimen holders made of epoxy resin-glass fiber composite. All specimens were then subject to artificial aging in an incubator at 37°C for 90 days. Fracture resistance of specimen assemblies was tested under static compression load using the universal testing machine based on ISO14801 specification. The peak fracture loads were recorded. All specimens were examined at the end of the test microscopically at 5× and 10× magnification to detect any catastrophic failures. Comparisons between groups for differences in peak fracture load were made using Wilcoxon Rank Sum tests and Weibull and Kaplan-Meier survival analyses (α = 0.05). RESULTS The TTC group (942 ± 241 N) showed significantly higher peak fracture loads than the ZZC (645 ± 165 N) and ZTS (650 ± 124 N) groups (p < 0.001), while there was no significant difference between ZZC and ZTS groups (p = 0.940). The survival probability based on the Weibull and Kaplan-Meier models demonstrated different failure molds between titanium-zirconium and zirconia implants, in which the TTC group remained in the plastic strain zone for a longer period before fracture when compared to ZZC and ZTS groups. Catastrophic failures, with implant fractures at the embedding level or slightly below, were only observed in the ZZC and ZTS groups. CONCLUSIONS Cement-retained zirconia crowns supported by titanium-zirconium implants and prefabricated titanium abutments showed superior peak fracture loads and better survival probability behavior. One-piece zirconia implants with cement-retained zirconia crowns and two-piece zirconia implants with screw-retained zirconia crowns on prefabricated titanium abutment showed similar peak fracture loads and survival probability behavior. Titanium-zirconium and zirconia implants could withstand average intraoral mastication loads in the incisor region. This study was conducted under static load, room temperature (21.7°C), and dry condition, and full impacts of intraoral hydrothermal aging and dynamic loading conditions on the zirconia implants should be considered and studied further.
Collapse
Affiliation(s)
- Brenda Hanes
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - Sabrina Feitosa
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, IN
| | - Kamolphob Phasuk
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - John A Levon
- Department of Prosthodontic Dentistry, Indiana University School of Dentistry, Indianapolis, IN
| | - Dean Morton
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - Wei-Shao Lin
- Advanced Education Program in Prosthodontics, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| |
Collapse
|
19
|
Sun F, Lv LT, Cheng W, Zhang JL, Ba DC, Song GQ, Lin Z. Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5542. [PMID: 34639935 PMCID: PMC8509834 DOI: 10.3390/ma14195542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 09/16/2021] [Accepted: 09/19/2021] [Indexed: 11/16/2022]
Abstract
Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Zeng Lin
- Key Laboratory of Implant Device and Interface Science of Liaoning Province, School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China; (F.S.); (L.-T.L.); (W.C.); (J.-L.Z.); (D.-C.B.); (G.-Q.S.)
| |
Collapse
|
20
|
Ban S. Classification and Properties of Dental Zirconia as Implant Fixtures and Superstructures. MATERIALS 2021; 14:ma14174879. [PMID: 34500970 PMCID: PMC8432657 DOI: 10.3390/ma14174879] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/16/2021] [Accepted: 08/24/2021] [Indexed: 11/16/2022]
Abstract
Various types of zirconia are widely used for the fabrication of dental implant superstructures and fixtures. Zirconia-alumina composites, such as ATZ and NanoZR, are adequate for implant fixtures because they have excellent mechanical strength in spite of insufficient esthetic properties. On the other hand, yttria-stabilized zirconia has been used for implant superstructures because of sufficient esthetic properties. They are classified to 12 types with yttria content, monochromatic/polychromatic, uniform/hybrid composition, and monolayer/multilayer. Zirconia with a higher yttria content has higher translucency and lower mechanical strength. Fracture strength of superstructures strongly depends on the strength on the occlusal contact region. It suggests that adequate zirconia should be selected as the superstructure crown, depending on whether strength or esthetics is prioritized. Low temperature degradation of zirconia decreases with yttria content, but even 3Y zirconia has a sufficient durability in oral condition. Although zirconia is the hardest dental materials, zirconia restorative rarely subjects the antagonist teeth to occlusal wear when it is mirror polished. Furthermore, zirconia has less bacterial adhesion and better soft tissue adhesion when it is mirror polished. This indicates that zirconia has advantageous for implant superstructures. As implant fixtures, zirconia is required for surface modification to obtain osseointegration to bone. Various surface treatments, such as roughening, surface activation, and coating, has been developed and improved. It is concluded that an adequately selected zirconia is a suitable material as implant superstructures and fixtures because of mechanically, esthetically, and biologically excellent properties.
Collapse
Affiliation(s)
- Seiji Ban
- Department of Dental Materials Science, School of Dentistry, Aichi Gakuin University, Nagoya 464-8650, Japan
| |
Collapse
|
21
|
Burkhardt F, Spies BC, Riemer L, Adolfsson E, Doerken S, Kohal RJ. Fracture resistance and crystal phase transformation of a one- and a two-piece zirconia implant with and without simultaneous loading and aging-An in vitro study. Clin Oral Implants Res 2021; 32:1288-1298. [PMID: 34352139 DOI: 10.1111/clr.13825] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Lennart Riemer
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | | | - Sam Doerken
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
22
|
Oxide Bioceramic Composites in Orthopedics and Dentistry. JOURNAL OF COMPOSITES SCIENCE 2021. [DOI: 10.3390/jcs5080206] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Ceramic composites based on alumina and zirconia have found a wide field of application in the present century in orthopedic joint replacements, and their use in dentistry is spreading. The development of this class of bioceramic composites was started in the 1980s, but the first clinical applications of the total hip replacement joint were introduced in the market only in the early 2000s. Since then, several composite systems were introduced in joint replacements. These materials are classified as Zirconia-Toughened Alumina if alumina is the main component or as Alumina-Toughened Zirconia when zirconia is the main component. In addition, some of them may contain a third phase based on strontium exa-aluminate. The flexibility in device design due to the excellent mechanical behavior of this class of bioceramics results in a number of innovative devices for joint replacements in the hip, the knee, and the shoulder, as well in dental implants. This paper gives an overview of the different materials available and on orthopedic and dental devices made out of oxide bioceramic composites today on the market or under development.
Collapse
|
23
|
Additively Manufactured Zirconia for Dental Applications. MATERIALS 2021; 14:ma14133694. [PMID: 34279264 PMCID: PMC8269801 DOI: 10.3390/ma14133694] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 06/27/2021] [Accepted: 06/28/2021] [Indexed: 11/17/2022]
Abstract
We aimed to assess the crystallography, microstructure and flexural strength of zirconia-based ceramics made by stereolithography (SLA). Two additively manufactured 3 mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP: LithaCon 3Y 230, Lithoz; 3D Mix zirconia, 3DCeram Sinto) and one alumina-toughened zirconia (ATZ: 3D Mix ATZ, 3DCeram Sinto) were compared to subtractively manufactured 3Y-TZP (control: LAVA Plus, 3M Oral Care). Crystallographic analysis was conducted by X-ray diffraction. Top surfaces and cross-sections of the subsurface microstructure were characterized using scanning electron microscopy (SEM). Biaxial flexural strength was statistically compared using Weibull analysis. The additively and subtractively manufactured zirconia grades revealed a similar phase composition. The residual porosity of the SLA 3Y-TZPs and ATZ was comparable to that of subtractively manufactured 3Y-TZP. Weibull analysis revealed that the additively manufactured LithaCon 3Y 230 (Lithoz) had a significantly lower biaxial flexural strength than 3D Mix ATZ (3D Ceram Sinto). The biaxial flexural strength of the subtractively manufactured LAVA Plus (3M Oral Care) was in between those of the additively manufactured 3Y-TZPs, with the additively manufactured ATZ significantly outperforming the subtractively manufactured 3Y-TZP. Additively manufactured 3Y-TZP showed comparable crystallography, microstructure and flexural strength as the subtractively manufactured zirconia, thus potentially being a good option for dental implants.
Collapse
|
24
|
Burkhardt F, Harlass M, Adolfsson E, Vach K, Spies BC, Kohal RJ. A Novel Zirconia-Based Composite Presents an Aging Resistant Material for Narrow-Diameter Ceramic Implants. MATERIALS 2021; 14:ma14092151. [PMID: 33922688 PMCID: PMC8122934 DOI: 10.3390/ma14092151] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 04/19/2021] [Accepted: 04/21/2021] [Indexed: 01/23/2023]
Abstract
A novel ceria-stabilized zirconia-alumina-aluminate composite (Ce-TZP-comp) that is not prone to aging presents a potential alternative to yttrium-stabilized zirconia for ceramic oral implants. The objective of this study was to evaluate the long-term stability of a one-piece narrow-diameter implant made of Ce-TZP-comp. Implant prototypes with a narrow (3.4 mm) and regular (4.0 mm) diameter were embedded according to ISO 14801, and subgroups (n = 8) were subsequently exposed to dynamic loading (107 cycles, 98N) and/or hydrothermal treatment (aging, 85 °C). Loading/aging was only applied as a combined protocol for the 4.0 mm diameter implants. One subgroup of each diameter remained untreated. One sample was cross-sectioned from each subgroup and evaluated with a scanning electron microscope for phase-transformation of the lattice. Finally, the remaining samples were loaded to fracture. A multivariate linear regression model was applied for statistical analyses (significance at p < 0.05). All samples withstood the different loading/aging protocols and no transformation propagation was observed. The narrow diameter implants showed the lowest fracture load after combined loading/aging (628 ± 56 N; p < 0.01), whereas all other subgroups exhibited no significantly reduced fracture resistance (between 762 ± 62 and 806 ± 73 N; p > 0.05). Therefore, fracture load values of Ce-TZP-comp implants suggest a reliable intraoral clinical application in the anterior jaw regions.
Collapse
Affiliation(s)
- Felix Burkhardt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Markus Harlass
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | | | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
- Correspondence:
| |
Collapse
|
25
|
Chaturvedi S, Alqahtani T, Alsolami S, Alqahtani A, Das G, Alsubaiy E. Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs. J Adv Prosthodont 2021; 13:36-45. [PMID: 33747393 PMCID: PMC7943750 DOI: 10.4047/jap.2021.13.1.36] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/21/2021] [Accepted: 02/02/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To investigate the fracture resistance of monolithic CAD-CAM all-ceramic surveyed crowns with two different occlusal rest seat designs. MATERIALS AND METHODS Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconia-material (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. RESULTS The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P <.001). CONCLUSION The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.
Collapse
Affiliation(s)
- Saurabh Chaturvedi
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Turki Alqahtani
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saleh Alsolami
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdulbari Alqahtani
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Gotam Das
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Ebrahim Alsubaiy
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
26
|
Giacon TA, Giancola F, Paganini M, Tiengo C, Camporesi EM, Bosco G. Hyperbaric Oxygen Therapy and A-PRF Pre-Treated Implants in Severe Periodontitis: A Case Report. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:E413. [PMID: 33430249 PMCID: PMC7825644 DOI: 10.3390/ijerph18020413] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 12/29/2020] [Accepted: 01/05/2021] [Indexed: 12/11/2022]
Abstract
Implantation is currently the best option for tooth replacement in periodontitis. Some major contraindications for the immediate implant are acute periodontitis and active infection. We present the case of a 51-year-old female patient with the highest grade and stage periodontitis treated with advanced platelet-rich fibrin-enriched zirconia implants and with hyperbaric oxygen therapy (HBOT). In particular, HBOT before and after implantation promoted bone regeneration and implant integration, also providing an antiseptic effect. After six months, the implants were well established and fully healed from periodontal disease within 14 months. Further research could confirm a new indication for HBOT in treating periodontitis and dental implantation.
Collapse
Affiliation(s)
- Tommaso Antonio Giacon
- Department of Biomedical Sciences, Environmental and Respiratory Physiology, University of Padova, Via Marzolo 3, 35131 Padova, Italy;
| | - Franco Giancola
- Clinica Europea Implantologia Ceramica, Domus Medica, 47890 Città di San Marino, San Marino;
| | - Matteo Paganini
- Department of Biomedical Sciences, Environmental and Respiratory Physiology, University of Padova, Via Marzolo 3, 35131 Padova, Italy;
| | - Cesare Tiengo
- Clinic of Plastic Reconstructive and Aesthetic Surgery, Padova University Hospital, 35128 Padova, Italy;
| | | | - Gerardo Bosco
- Department of Biomedical Sciences, Environmental and Respiratory Physiology, University of Padova, Via Marzolo 3, 35131 Padova, Italy;
| |
Collapse
|
27
|
Yeo ISL. Special Issue: Dental Implant Materials 2019. MATERIALS 2020; 13:ma13245790. [PMID: 33352980 PMCID: PMC7766183 DOI: 10.3390/ma13245790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 12/18/2020] [Indexed: 11/16/2022]
Affiliation(s)
- In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-Ro, Jongro-Gu, Seoul 03080, Korea
| |
Collapse
|
28
|
Gao J, Min J, Chen X, Yu P, Tan X, Zhang Q, Yu H. Effects of two fretting damage modes on the dental implant–abutment interface and the generation of metal wear debris: An in vitro study. FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES 2020. [DOI: 10.1111/ffe.13399] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Jing Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Jie Min
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Xin Chen
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Ping Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Xin Tan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Qianqian Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| |
Collapse
|
29
|
Lorusso F, Noumbissi S, Francesco I, Rapone B, Khater AGA, Scarano A. Scientific Trends in Clinical Research on Zirconia Dental Implants: A Bibliometric Review. MATERIALS 2020; 13:ma13235534. [PMID: 33291827 PMCID: PMC7730252 DOI: 10.3390/ma13235534] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/29/2020] [Accepted: 12/02/2020] [Indexed: 12/13/2022]
Abstract
Background: The clinical use of zirconia implants has been shown to increase steadily due to their biological, aesthetic, and physical properties; therefore, this bibliometric study aimed to review the clinical research and co-authors in the field of zirconia dental implant rehabilitation. Methods: We searched Scopus and Web of Science databases using a comprehensive search strategy to 5 October 2020, and independently paired reviewers who screened studies, and collected data with inclusion criteria restricted to clinical research only (either prospective or retrospective). Data on article title, co-authors, number of citations received, journal details, publication year, country and institution involved, funding, study design, marginal bone loss, survival rate, failure, follow-up, and the author’s bibliometric data were collected and evaluated. Results: A total of 29 clinical studies were published between 2008 and 2020 as 41.4% were prospective cohort studies and 48.3% originated from Germany. Most of the included studies had been published in Clinical Oral Implant Research (n = 12), and the most productive institution was the Medical Center of University of Freiburg. The author with the largest number of clinical studies on zirconia implants was Kohal R.J. (n = 10), followed by Spies B.C. (n = 8). Conclusions: This study revealed that zirconia implants have been more prominent in the last ten years, which is a valuable option for oral rehabilitation with marginal bone loss and survival rate comparable to titanium dental implants.
Collapse
Affiliation(s)
- Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Sammy Noumbissi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Inchingolo Francesco
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Biagio Rapone
- Department of Basic Medical Sciences, Neurosciences and Sense Organs, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Ahmad G. A. Khater
- Faculty of Oral and Dental Medicine, Ahram Canadian University, 6th of October City, 8655 Giza, Egypt;
| | - Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
- Correspondence: ; Tel.: +39-0871-355-4084; Fax: +39-0871-355-4099
| |
Collapse
|
30
|
Bagegni A, Spies BC, Kern M, Hazard D, Kohal R. The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study. J Mech Behav Biomed Mater 2020; 113:104095. [PMID: 33017717 DOI: 10.1016/j.jmbbm.2020.104095] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/09/2020] [Accepted: 09/14/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND AND AIM Long-term edentulism associated with vertical loss of alveolar bone might lead to increased suprastructure height. This study aimed to evaluate the effect of suprastructure height on the stability of the implant-abutment connection by investigating the stability of two different two-piece titanium implants with internal hexagonal or conical connections under simulated oral loading conditions. MATERIALS AND METHODS A total of 48 specimens were used. The specimens were divided into 2 groups according to their implant-abutment connection (group H: internal hex connection, group C: conical connection). Each group was further divided into 3 groups according to the applied suprastructure height (H1; C1: 10 mm, H2; C2: 14 mm and H3; C3: 18 mm) (n = 8). All specimens were subjected to a cyclic loading force of 98 N for 5 million simulated chewing cycles. Then, all implants that survived the chewing simulation were quasi-statically loaded until failure. The monotonic-failure load and monotonic-bending moment at failure were evaluated. RESULTS After the dynamic chewing loading, the implants showed the following survival rates: group H: 95.8%; group C: 100%. The implant suprastructures revealed survival rates of 100% and 91.5% for groups H and C, respectively. After the artificial chewing simulation of 5 million cycles, some implants in the groups with higher crowns (14 mm and 18 mm) showed crack formation and plastic deformations under the light microscope. Regarding monotonic-failure load, implants with shorter suprastructures (10 mm) revealed higher resistance to failure (C1: 1496 and H1: 1201 N) than longer suprastructures (18 mm) (C3: 465 and H3: 585 N) which was expected. The mean monotonic-bending moment values at failure ranged from 400.7 Ncm to 673.3 Ncm. CONCLUSION Implant-supported restorations with increased crown height are considered stable for an extended time period (5 million cycles which equals approximately 20 years clinical service) and a reliable treatment option in case of increased inter-arch distance. There was no difference in stability of the two internal connections. Nevertheless, the integrity of implant components might be impaired when crowns with increased heights are applied.
Collapse
Affiliation(s)
- Aimen Bagegni
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Benedikt C Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Arnold-Heller-Straße 3, 24105, Kiel, Germany.
| | - Derek Hazard
- Medical Center - University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine - University of Freiburg, Ernst-Zermelo-Straße 1, 79104, Freiburg, Germany.
| | - Ralf Kohal
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| |
Collapse
|
31
|
A Prospective Clinical Cohort Investigation on Zirconia Implants: 5-Year Results. J Clin Med 2020; 9:jcm9082585. [PMID: 32785031 PMCID: PMC7464596 DOI: 10.3390/jcm9082585] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/21/2020] [Accepted: 08/06/2020] [Indexed: 12/17/2022] Open
Abstract
Mid-term data on zirconia oral implants is very rare. Therefore, the aim of this prospective clinical investigation was to evaluate the survival rate and the marginal bone loss of a one-piece zirconia implant after five years. Patient-reported outcomes were also recorded. Zirconia implants to support single crowns (SC) or a 3-unit fixed dental prosthesis (FDP) were placed and subsequently restored. After the insertion of the implants, at prosthetic delivery, and after five years, standardized radiographs were taken to evaluate marginal bone loss (MBL). For bone tissue evaluation, linear mixed models with random intercepts were fitted. Twenty-seven patients received one implant for an SC and 13 patients received two implants for a 3-unit FDP. Three patients each lost one implant for an SC before prosthetic delivery. Thirty-five patients were seen after five years, and no further implant was lost. The cumulative five-year implant survival rate was 94.3%. The MBL from implant installation up to five years was 0.81 mm. The MBL from implant installation to prosthetic delivery was statistically significant (p < 0.001). Patients perceived a significant improvement in function, esthetics, sense, speech, and self-esteem from pretreatment up to the five-year follow-up. The present findings substantiate the clinical applicability of this implant system.
Collapse
|
32
|
Digitization of One-Piece Oral Implants: A Feasibility Study. MATERIALS 2020; 13:ma13081990. [PMID: 32344639 PMCID: PMC7215390 DOI: 10.3390/ma13081990] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 04/13/2020] [Accepted: 04/23/2020] [Indexed: 11/16/2022]
Abstract
For digital impression-making of two-piece oral implants, scan bodies are used to transfer the exact intraoral implant position to the dental laboratory. In this in vitro investigation, the accuracy of digitizing a one-piece ceramic oral implant without a scan body (OC) was compared to that of a standard two-piece titanium implant with a scan body (TT) and a preparation of a natural single tooth (ST). Furthermore, incomplete scans of OC simulating clinical compromising situations (OC1–4) were redesigned using a virtual reconstruction tool (RT) and superimposed to OC. OC and TT oral implants and one ST were inserted into a mandible typodont model and digitized (N = 13) using two different intraoral scanners. The resulting virtual datasets were superimposed onto a three-dimensional (3D) laser scanner-based reference. Test and reference groups were aligned using an inspection software according to a best-fit algorithm, and circumferential as well as marginal discrepancies were measured. For the statistical evaluation, multivariate analyses of variance with post-hoc Tukey tests and students t-tests to compare both scanners were performed. A total of 182 datasets were analyzed. For circumferential deviations, no significant differences were found between ST, TT, and OC (p > 0.964), but increased deviations for OC1–4 (p < 0.001) were observed. The measurements of the marginal deviations revealed that ST had the smallest deviations, and that there were no significant differences between TT, OC, and OC1–4 (p > 0.979). Except for marginal deviation of OC (p < 0.001), the outcome was not affected by the scanner. Within the limitations of this study, digitization of OC is as accurate as that of TT, but less than that of ST. In the case of known geometries, post-processing of compromised scans with a virtual reconstruction results in accurate data.
Collapse
|