1
|
Chen H, Sun D, Fang Y, Gao S, Zhang Q, Bíró I, Tafferner-Gulyás V, Gu Y. Effect of orthopedic insoles on lower limb motion kinematics and kinetics in adults with flat foot: a systematic review. Front Bioeng Biotechnol 2024; 12:1435554. [PMID: 39070160 PMCID: PMC11273083 DOI: 10.3389/fbioe.2024.1435554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 06/19/2024] [Indexed: 07/30/2024] Open
Abstract
Flatfoot is characterized by the collapse of the medial longitudinal arch, eversion of the rearfoot and abduction of the loaded forefoot. Orthopedic insoles are the frequently recommended treatment to support the arch of the foot, adjust the structure of the foot, reduce pain, improve stability and new techniques have been applied to the design of orthopedic insoles in recent years. However, the effectiveness of orthopedic insoles in different motions is still debated from the perspective of biomechanics. Therefore, this study aimed to explore the impact of orthopedic insoles on the kinematics and kinetics of lower limb motion, and to verify effectiveness and propose possible future research directions. We conducted a literature search across three databases employing Boolean operations and filtered results based on eligibility criteria. A total of 671 relevant literature were searched in this review, and 19 literature meeting the requirements were finally included. The results showed that: 1) orthopedic insoles were effective when patients walk, run and jump from the perspective of biomechanics; 2) orthopedic insoles had different result on the change of ankle sagittal angle, moment and peak pressure in the metatarsal region; 3) Whether the effect of insoles, which uses new techniques such as different 3D printed technologies and adds various accessories, can be further improved remains to be further studied; 4) Follow-up studies can pay more attention to the differences between diverse populations, increase the breadth of running and jumping and other movements research and long-term intervention.
Collapse
Affiliation(s)
- Hairong Chen
- Ningbo No. 2 Hospital, Ningbo, China
- Faculty of Sports Science, Ningbo University, Ningbo, China
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
| | - Dong Sun
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | | | - Shunxiang Gao
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Qiaolin Zhang
- Faculty of Sports Science, Ningbo University, Ningbo, China
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
- Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - István Bíró
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
| | | | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo, China
| |
Collapse
|
2
|
Alsaafin N, Saad N, Mohammad Zadeh SA, Hegazy FA. Effect of Different Foot Orthosis Inverted Angles on Walking Kinematics in Females with Flexible Flatfeet. J Multidiscip Healthc 2023; 16:2613-2623. [PMID: 37693854 PMCID: PMC10492546 DOI: 10.2147/jmdh.s420003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 08/16/2023] [Indexed: 09/12/2023] Open
Abstract
Background Although the inverted technique was shown to be more effective compared to other orthotic designs for the treatment of flatfeet, the biomechanical mechanisms underlying the therapeutic effect of the inverted angle orthoses is still unclear. Therefore, the aim of this study was to examine the effect of different inverted angles of foot orthoses on walking kinematics in females with flexible flatfeet. Methods Thirty-one female adults with flexible flatfeet aged 18-35 years old participated in this study. Kinematic data of the hip, knee, and ankle were collected via BTS motion-capture system during walking under three test conditions in random order: with shoes only; with 15° inverted orthoses; and with 25° inverted orthoses. Results Compared to the shoes only condition, both the 15° and 25° inverted orthotic conditions significantly decreased the maximum ankle plantarflexion angle during loading response, maximum ankle dorsiflexion angle during mid-stance, maximum ankle external rotation angle, and maximum ankle internal rotation angle. The maximum ankle plantarflexion angle at toe-off showed a significant decrease with the 25° inverted angle orthosis compared to both the 15° inverted angle and shoes only conditions. No significant differences were found in the knee kinematic variables, maximum hip extension angle, and maximum hip adduction angle between test conditions. Conclusion Using inverted orthoses at 15° and 25° inverted angles resulted in significant changes in ankle joint kinematics during walking in female adults with flexible flatfeet. A 25° inverted angle orthosis significantly decreased ankle plantarflexion during push-off, potentially impacting gait mechanics. This suggests that a smaller inverted angle may be more effective for managing flexible flatfeet in female adults.
Collapse
Affiliation(s)
- Nour Alsaafin
- Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
| | - Nabil Saad
- Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
| | - Shima A Mohammad Zadeh
- Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
| | - Fatma A Hegazy
- Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
| |
Collapse
|
3
|
Ghorbani M, Yaali R, Sadeghi H, Luczak T. The effect of foot posture on static balance, ankle and knee proprioception in 18-to-25-year-old female student: a cross-sectional study. BMC Musculoskelet Disord 2023; 24:547. [PMID: 37403076 DOI: 10.1186/s12891-023-06678-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 06/29/2023] [Indexed: 07/06/2023] Open
Abstract
BACKGROUND & PURPOSE Afferent input from the sole affects postural stability. Cutaneous reflexes from the foot are important to posture and gait. Lower-limb afferents alone provide enough information to maintain upright stance and are critical in perceiving postural sway. Altered feedback from propreoceptive receptors alters gait and patterns of muscle activation. The position and posture of the foot and ankle may also play an important role in proprioceptive input.Therefore, the current research aims to compare static balance and ankle and knee proprioception in people with and without flexible flatfeet. METHODOLOGY 91 female students between the ages of 18 and 25 voluntarily participated in this study, of which 24 were in the flexible flatfoot group and 67 were in the regular foot group after evaluating the longitudinal arch of the foot. The position sense of ankle and knee joints were measured using the active reconstruction test of the ankle and knee angle; Static balance was measured using the Sharpened Romberg test. Data were non-normally distributed. Accordingly, non-parametric tests were applied. The Kruskal-Wallis test was applied to compare differences between groups in variables. RESULT Kruskal-Wallis test showed a significant difference between two groups of flat feet and normal feet in the variables of static balance and position sense of ankle plantarflexion, ankle dorsiflexion, and knee flexion (p ≤ 0.05). A significant correlation was found between static balance and sense of ankle and knee position in the group with normal feet. The analysis of the regression line also showed that ankle and knee position sense could predict the static balance score in the regular foot group (ankle dorsiflexion position sense 17% (R2 = 0.17), ankle plantarflexion position sense 17% (R2 = 0.17) and knee flexion position sense 46% (R2 = 0.46) explain of changes in static balance). DISCUSSION & CONCLUSION Flexible flatfoot soles can cause loss of balance and sense of joint position; therefore, according to this preliminary study, clinicians must be aware and should take into account this possible deficit in the management of these patients.
Collapse
Affiliation(s)
- Maryam Ghorbani
- Department of Motor Behavior, Faculty of Physical Education and Sport Sciences, Kharazmi University of Tehran, Tehran, Iran
| | - Rasoul Yaali
- Department of Motor Behavior, Faculty of Physical Education and Sport Sciences, Kharazmi University of Tehran, Tehran, Iran.
| | - Hassan Sadeghi
- Department of Biomechanics and Sports Injuries, Faculty of Physical Education and Sport Sciences, Kharazmi University of Tehran, Tehran, Iran
| | - Tony Luczak
- NSPARC, Mississippi State University, Mississippi, USA
| |
Collapse
|
4
|
Žukauskas S, Barauskas V, Degliūtė-Muller R, Čekanauskas E. Really Asymptomatic? Health-Related Quality of Life and Objective Clinical Foot Characteristics among 5-10-Year-Old Children with a Flexible FlatFoot. J Clin Med 2023; 12:jcm12093331. [PMID: 37176771 PMCID: PMC10179374 DOI: 10.3390/jcm12093331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 04/30/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023] Open
Abstract
The potential effects of asymptomatic flexible flatfoot (FF) on children's health-related quality of life (QoL) and objective clinical foot characteristics have been poorly investigated in the literature. Therefore, this study aimed to analyse these indicators, comparing the children with asymptomatic FF and a control group. METHODS In total, 351 children were enrolled in this cross-sectional study-160 children with asymptomatic FF and 191 controls (children with normal feet). The children and their parents completed the Paediatric Quality of Life Inventory (PedsQLTM 4.0). The objective foot characteristics included clinical foot posture measures, footprints, general hyperlaxity, and X-ray measurements. RESULTS Children with asymptomatic FF had a significantly lower QoL (overall and all four dimensions). The parents' assessment of the QoL of their children with asymptomatic FF in most cases was lower compared to their children's self-reported QoL. Moreover, almost all clinical foot measures also had significantly worse profiles among asymptomatic FF cases compared to the controls. This was observed with the Foot Posture Index-6 (FPI-6), the navicular drop (ND) test, the Chippaux-Smirak Index (CSI), Staheli's Index (SI), the Beighton scale, and radiological angles (except the talo-first metatarsal angle). CONCLUSION The findings suggest that asymptomatic FF not always reflects a normal foot development. This condition is related to decreased health-related quality of life, so the 5-10-year-old children's and their parents' complaints should be considered more closely in identification, treatment, and monitoring plans.
Collapse
Affiliation(s)
- Saidas Žukauskas
- Department of Paediatric Surgery, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania
| | - Vidmantas Barauskas
- Department of Paediatric Surgery, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania
| | - Ramunė Degliūtė-Muller
- Department of Paediatric Surgery, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania
| | - Emilis Čekanauskas
- Department of Paediatric Surgery, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania
| |
Collapse
|
5
|
Channasanon S, Praewpipat B, Duangjinda N, Sornchalerm L, Tesavibul P, Paecharoen S, Tanodekaew S. 3D-printed medial arch supports of varying hardness versus a prefabricated arch support on plantar pressure: A 1-month randomized crossover study in healthy volunteers. Prosthet Orthot Int 2023; 47:210-217. [PMID: 36037286 DOI: 10.1097/pxr.0000000000000178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 06/01/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Foot orthoses are commonly used as a noninvasive treatment to relieve foot pain. The custom full-length insoles with various materials and designs have been studied for their effectiveness in reducing plantar pressure. However, few studies have been conducted with respect to custom medial arch support on the relationships between material hardness and measured plantar pressure and level of comfort. OBJECTIVES To evaluate the effects of the hardness of custom medial arch supports on plantar pressure and comfort perception. STUDY DESIGN Randomized crossover study. METHODS Two custom silicone medial arch supports of varying hardness (A and B) were fabricated using 3D printing technology and tested in 12 healthy volunteers against a commercially prefabricated arch support (C). The volunteers wore three medial arch supports in a random order, one month for each arch support with 3-4 days of washout period before wearing the next one. The plantar pressure was measured and analyzed according to each foot zone: forefoot, midfoot, and hindfoot, comparing before intervention, immediately after intervention, and 1 month after intervention. The comfort perception was assessed by collecting volunteer feedback with a questionnaire after using each medial arch support. RESULTS After 1-month intervention, both 3D-printed and prefabricated medial arch supports demonstrated significantly higher average pressure in the midfoot ( P < 0.001), whereas significantly lower average pressure in the forefoot ( P < 0.001) and hindfoot ( P = 0.014, 0.026, and 0.018 for A, B, and C, respectively), compared with those before intervention. There were no significant differences in plantar pressure distribution between the 3D-printed and prefabricated medial arch supports. However, the 3D-printed medial arch supports resulted in better comfort than the prefabricated arch support. CONCLUSIONS The material hardness had no apparent effect on plantar pressure distribution. The three medial arch supports showed reducing plantar heel pressure. Further research is needed to investigate the potential effect of 3D-printed silicone medial arch supports on reducing foot pain in patients.
Collapse
Affiliation(s)
- Somruethai Channasanon
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| | - Bongkoch Praewpipat
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| | - Nitkamon Duangjinda
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| | - Lertchai Sornchalerm
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| | - Passakorn Tesavibul
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| | - Siranya Paecharoen
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Thammasat University, Pathumthani, Thailand
| | - Siriporn Tanodekaew
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathumthani, Thailand
| |
Collapse
|
6
|
Wong DWC, Wang Y, Niu W, Zhang M. Response to the letter to editor regarding "finite element analysis of subtalar joint arthroereisis on adult acquired flexible flatfoot deformity using customized sinus tarsi implant". J Orthop Translat 2022; 37:173-174. [PMID: 36569456 PMCID: PMC9747350 DOI: 10.1016/j.jot.2022.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 12/05/2022] [Indexed: 12/14/2022] Open
Affiliation(s)
- Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China,The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China,Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong, China,Corresponding author. Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Yan Wang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China,The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China,Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong, China
| | - Wenxin Niu
- Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai 201619, China
| | - Ming Zhang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China,The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China,Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong, China,Corresponding author. Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| |
Collapse
|
7
|
Storm FA, Redaelli DF, Biffi E, Reni G, Fraschini P. Additive Manufacturing of Spinal Braces: Evaluation of Production Process and Postural Stability in Patients with Scoliosis. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6221. [PMID: 36143533 PMCID: PMC9502321 DOI: 10.3390/ma15186221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/05/2022] [Accepted: 09/06/2022] [Indexed: 06/16/2023]
Abstract
Spinal orthoses produced using additive manufacturing show great potential for obtaining patient-specific solutions in clinical applications, reducing manual operations, time consumption, and material waste. This study was conducted to evaluate the production process of spinal orthoses produced by additive manufacturing, and to test the effects of 3D-printed braces on postural stability in patients with adolescent idiopathic scoliosis and osteogenesis imperfecta. Ten patients were recruited consecutively and were asked to wear a spinal orthosis produced by additive manufacturing for 2 weeks. The four phases of the production process for each brace were evaluated separately on a scale from 0 (not acceptable) to 3 (optimal). Postural stability in the unbraced and the two braced conditions (3D-printed and conventional) was assessed using validated metrics obtained from a wearable inertial sensor. The production process was evaluated as good in four cases, acceptable in five cases, and not acceptable in one case, due to problems in the printing phase. No statistically significant differences were observed in any of the postural balance metrics between the 3D-printed and conventional brace. On the other hand, postural balance metrics improved significantly with both types of braces with respect to the unbraced condition. Spinal orthoses produced with an innovative production process based on digital scans, CAD, and 3D printing are valid alternatives to conventionally produced orthoses, providing equivalent postural stability.
Collapse
|
8
|
Immediate Effect of Customized Foot Orthosis on Plantar Pressure and Contact Area in Patients with Symptomatic Hallux Valgus. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Foot orthotics are recommended for the treatment of hallux valgus. The effects of customized foot orthoses (FOs) designed with both medial longitudinal and transverse arch supports are poorly understood, however. This study aimed to investigate the immediate effect of customized FOs on the plantar pressure and contact area in patients with symptomatic hallux valgus. We recruited 18 patients with a mean hallux valgus angle of 27.3 ± 11.1°. Plantar pressure while walking with FOs or flat insoles (FIs) was monitored with a wireless in-shoe plantar pressure-sensing system. Peak pressure (PP), peak force (PF), pressure-time integral (PTI), force-time integral (FTI), and contact area with FOs and FIs were compared. The PF, PTI, and FTI of the midfoot were significantly higher (p < 0.05), and the PP and PTI of the rearfoot were significantly lower (p < 0.05) with the FOs than the FIs. The FOs significantly increased the contact area of the midfoot and rearfoot (p < 0.05) and reduced the contact area of the forefoot (p < 0.05). These results suggest that customized FOs redistribute plantar pressure and the contact area of the midfoot and rearfoot, improving the functional support of the midfoot for patients with hallux valgus.
Collapse
|
9
|
Peng Y, Wang Y, Wong DWC, Chen TLW, Chen SF, Zhang G, Tan Q, Zhang M. Different Design Feature Combinations of Flatfoot Orthosis on Plantar Fascia Strain and Plantar Pressure: A Muscle-Driven Finite Element Analysis With Taguchi Method. Front Bioeng Biotechnol 2022; 10:853085. [PMID: 35360398 PMCID: PMC8960448 DOI: 10.3389/fbioe.2022.853085] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 02/18/2022] [Indexed: 11/23/2022] Open
Abstract
Customized foot orthosis is commonly used to modify foot posture and relieve foot pain for adult acquired flexible flatfoot. However, systematic investigation of the influence of foot orthotic design parameter combination on the internal foot mechanics remains scarce. This study aimed to investigate the biomechanical effects of different combinations of foot orthoses design features through a muscle-driven flatfoot finite element model. A flatfoot-orthosis finite element model was constructed by considering the three-dimensional geometry of plantar fascia. The plantar fascia model accounted for the interaction with the bulk soft tissue. The Taguchi approach was adopted to analyze the significance of four design factors combination (arch support height, medial posting inclination, heel cup height, and material stiffness). Predicted plantar pressure and plantar fascia strains in different design combinations at the midstance instant were reported. The results indicated that the foot orthosis with higher arch support (45.7%) and medial inclination angle (25.5%) effectively reduced peak plantar pressure. For the proximal plantar fascia strain, arch support (41.8%) and material stiffness (37%) were strong influencing factors. Specifically, higher arch support and softer material decreased the peak plantar fascia strain. The plantar pressure and plantar fascia loading were sensitive to the arch support feature. The proposed statistics-based finite element flatfoot model could assist the insole optimization and evaluation for individuals with flatfoot.
Collapse
Affiliation(s)
- Yinghu Peng
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen, China
| | - Yan Wang
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
| | - Tony Lin-Wei Chen
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Shane Fei Chen
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Guoxin Zhang
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Qitao Tan
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Ming Zhang
- Department of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
- *Correspondence: Ming Zhang,
| |
Collapse
|