1
|
Khijmatgar S, Tumedei M, Tartaglia G, Crescentini M, Isola G, Sidoti E, Sforza C, Del Fabbro M, Tartaglia GM. Fifteen-year recall period on zirconia-based single crowns and fixed dental prostheses. A prospective observational study. BDJ Open 2024; 10:54. [PMID: 38902278 PMCID: PMC11190277 DOI: 10.1038/s41405-024-00214-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/13/2024] [Accepted: 03/13/2024] [Indexed: 06/22/2024] Open
Abstract
AIM The aim of this study was to evaluate the long-term clinical outcomes of zirconia-based prostheses used for tooth-supported or implant-supported single crowns and fixed dental prostheses (FPD). METHODS The authors conducted a prospective analysis of 562 zirconia core restorations supported by endodontically treated teeth or titanium implant in 276 patients in a general dental private practice, with a follow-up period of 15 years. The study was stopped after patients achieved 15 yrs of follow-up. The study analyzed the failure and complication rates of single and multiple crowns, based on Kaplan Meier analysis. RESULTS During follow-up period, there were 26 complications and 156 failures. The crown level analysis revealed a cumulative failure rate of 28.33% and complication rate of 8.47% for zirconia crowns after 15 years. The complication rate was found to be higher for titanium implant-supported than for natural teeth-supported crowns. The different types of crown-based failure include: veener fracture 5.01% (N = 29), metal zirconia led to 14.85% (N = 86) loss of retention, and 1.73% (N = 10) loss of crown due to extraction. CONCLUSION Based on these findings, zirconia core restorations appear to be a reliable long-term solution for crowns and fixed dental prostheses. CLINICAL RELEVANCE The study suggests that zirconia restorations can be successfully used for long-term prostheses on natural teeth or implants supported. The study results provide clinicians valuable information when selecting prosthetic restorations material.
Collapse
Affiliation(s)
| | - Margherita Tumedei
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- School of Medicine, University of Madrid, Madrid, Spain
| | | | | | - Gaetano Isola
- Department of General Surgery and Surgical-Medical Specialties, School of Dentistry, University of Catania, Via S. Sofia 78, 95124, Catania, Italy
| | | | - Chiarella Sforza
- Department of Biomedical Sciences for Health, University of Milan, Via Mangiagalli 31, 20133, Milan, Italy
| | - Massimo Del Fabbro
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- School of Medicine, University of Madrid, Madrid, Spain
| | - Gianluca Martino Tartaglia
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- School of Medicine, University of Madrid, Madrid, Spain.
| |
Collapse
|
2
|
Ribeiro AKC, Gomes ACG, de Oliveira LAL, de Araújo Silva DN, de Aquino LMM, de Aquino Martins ARL. Evaluation of periodontal parameters on abutment teeth rehabilitated with single-unit crowns: A 12-month follow-up. Saudi Dent J 2024; 36:887-893. [PMID: 38883896 PMCID: PMC11178954 DOI: 10.1016/j.sdentj.2024.03.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 03/24/2024] [Accepted: 03/25/2024] [Indexed: 06/18/2024] Open
Abstract
Purpose This prospective study evaluated the effects of the metal-free crowns on the periodontal tissues of abutment teeth during a 12-month follow-up. Materials and Methods A sample of 24 patients (N = 32 abutment teeth) who needed a single-tooth restoration were enrolled to receive either a metal-ceramic (n = 21) or lithium disilicate (n = 11). The single-unit crowns were evaluated at baseline, 3-and 12-month follow-up. The periodontal parameters were evaluated: plaque index (PI), gingival bleeding index (GBI), bleeding on probing (BOP), probing depth (PD), clinical attachment loss (CAL), radiographically and clinical crown fitting, bone resorption, and marginal finish lines. Statistical analyses were performed using the Exact Fisher and Mann-Whitney tests, and the Wilcoxon signed-rank test as a post hoc test for Friedman (95 % confidence interval). Results The marginal finish line showed a statistical difference with a biomaterial type (p =.004). After a 12-months, a significant increase was observed in PI and mean PD for abutment teeth of metal-ceramic crowns. The metal-free crowns presented higher values for GBI and CAL (p2 < 0.05). Only distal cervical evaluation and dental biofilm formation in the abutment teeth showed a statistical difference between the groups at the 12-month follow-up. The supragingival margin metal-ceramic group revealed higher PI values (p2 = 0.005) between the period and the subgingival margin of both biomaterials showed greater GBI scores (p2 < 0.05). Conclusions Metal-free crowns showed better periodontal outcomes compared to metal-ceramic crowns. Single-unit crown marginal location affects the periodontal tissue condition of the abutment teeth. The marginal fit was not changed regarding the biomaterial type.
Collapse
Affiliation(s)
| | | | | | - Davi Neto de Araújo Silva
- Section of Periodontics, School of Dentistry, University of California, Los Angeles, CA, United States
| | | | | |
Collapse
|
3
|
Gseibat M, Sevilla P, Lopez-Suarez C, Rodriguez V, Pelaez J, Suarez MJ. Performance of posterior third-generation monolithic zirconia crowns in a complete digital workflow: A three-year prospective clinical study. J Dent Sci 2024; 19:871-877. [PMID: 38618120 PMCID: PMC11010711 DOI: 10.1016/j.jds.2023.08.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/20/2023] [Indexed: 04/16/2024] Open
Abstract
Background/purpose Translucent monolithic zirconia restorations have recently introduced. The purpose of this study was to evaluate the clinical behavior and the survival rate of the posterior third-generation monolithic zirconia crowns (MZCs) during three years of clinical service. Materials and methods Twenty-four patients who needed thirty crowns were enrolled in this study. Digital impressions were made, and the crowns were milled and cemented with a resin cement. The crowns outcomes were assessed using the California Dental Association's (CDA) criteria. Gingival index (GI), plaque index (PI), and periodontal probing depth (PPD) for MZCs and contralateral natural teeth (control) were assessed. Margin index (MI) for MZCs was also assessed. Data analysis was conducted using the Wilcoxon signed-rank and the Friedman tests. Results The 3-year survival rate was 100%. All MZCs were rated as satisfactory throughout the follow-up period, and no biological or mechanical complications were observed. No differences were recorded when GI, PI and PPD at 3-year of follow-up were compared to baseline. No differences were recorded between crowned and control teeth. The MI remained stable throughout the study period. Conclusion The third-generation monolithic zirconia appears to be a good treatment option for the rehabilitation of posterior single teeth.
Collapse
Affiliation(s)
- Mustafa Gseibat
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Pablo Sevilla
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Carlos Lopez-Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Veronica Rodriguez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Jesus Pelaez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Maria J. Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
4
|
Benalcázar-Jalkh EB, Bergamo ETP, Campos TMB, Coelho PG, Sailer I, Yamaguchi S, Alves LMM, Witek L, Tebcherani SM, Bonfante EA. A Narrative Review on Polycrystalline Ceramics for Dental Applications and Proposed Update of a Classification System. MATERIALS (BASEL, SWITZERLAND) 2023; 16:7541. [PMID: 38138684 PMCID: PMC10744432 DOI: 10.3390/ma16247541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/07/2023] [Accepted: 11/25/2023] [Indexed: 12/24/2023]
Abstract
Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.
Collapse
Affiliation(s)
- Ernesto B. Benalcázar-Jalkh
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil
| | - Edmara T. P. Bergamo
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Prosthodontics, NYU Dentistry, New York, NY 10010, USA
| | - Tiago M. B. Campos
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil
| | - Paulo G. Coelho
- DeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, Miller School of Medicine, University of Miami, Miami, FL 33136, USA
- Department of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL 33136, USA
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, 1211 Geneva, Switzerland
| | - Satoshi Yamaguchi
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, Suita 565-0871, Osaka, Japan;
| | - Larissa M. M. Alves
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil
| | - Lukasz Witek
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Biomedical Engineering, NYU Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA
- Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY 10017, USA
| | - Sérgio M. Tebcherani
- Department of Production Engineering, Federal University of Technology—Paraná, Av. Monteiro Lobato Km 04, Ponta Grossa 84016-210, PR, Brazil;
| | - Estevam A. Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil
| |
Collapse
|
5
|
Silva NR, Araújo GD, Moura D, Araújo LD, Gurgel BDV, Melo RM, Bottino MA, Özcan M, Zhang Y, Souza R. Clinical Performance of Minimally Invasive Monolithic Ultratranslucent Zirconia Veneers: A Case Series up to Five Years of Follow-up. Oper Dent 2023; 48:606-617. [PMID: 37961016 DOI: 10.2341/22-118-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/05/2023] [Indexed: 11/15/2023]
Abstract
There is a lack of reports in the literature on the long-term clinical performance of ultratranslucent zirconia, especially considering its use in manufacturing monolithic veneers. The purpose of this case series is to describe the aesthetic treatment steps of three patients with minimally invasive ultratranslucent zirconia veneers and to report the clinical findings up to five years. Three patients (woman: 2, man: 1; mean age: 30 years) unsatisfied with their dental aesthetics sought dental treatment. The treatment plan involved cementing ultratranslucent zirconia veneers. Air-abrasion was performed on the internal surface of zirconia with alumina particles coated by silica (silicatization), followed by silane and adhesive applications for the adhesive cementation. All veneers were adhesively cemented to enamel with resin cement (Variolink Esthetic, Ivoclar). The patients were clinically evaluated annually considering the Ryge modified/ California Dental Association criteria. After a mean follow-up of 4.33 years (4-5 years), a survival rate of 100% was detected for the 28 minimally invasive ultratranslucent zirconia veneers cemented in the 3 patients. There were no absolute failures such as debonding, veneer fracture, or secondary caries. Superficial marginal discoloration was observed in one element (maxillary left lateral incisor) of one patient. Ultratranslucent zirconia is a viable option for manufacturing veneers due to its excellent clinical performance and longevity. However, further long-term clinical studies are essential to consolidate this material as an option for esthetic restorations.
Collapse
Affiliation(s)
- N R Silva
- Nathalia Ramos Silva, DDs, MSc, PhD, Federal University of Rio Grande do Norte (UFRN), Brazil
| | - Gm de Araújo
- Gabriela Monteiro de Araújo, DDs, MSc, PhD, Federal University of Rio Grande do Norte (UFRN), Brazil
| | - Dmd Moura
- Dayanne Monteiro Duarte Moura, DDS, MSc, PhD, professor, State University of Rio Grande do Norte (UERN), Brazil
| | - Lnm de Araújo
- Lidya Nara Marques de Araújo, DDs, MSc, PhD, Federal University of Rio Grande do Norte (UFRN), Brazil
| | - Bc de Vasconcelos Gurgel
- Bruno César de Vasconcelos Gurgel, DDs, MSc, PhD, professor, Federal University of Rio Grande do Norte (UFRN), Brazil
| | - R M Melo
- Renata Marques Melo, DDS, MSc, PhD, professor, São Paulo State University (UNESP/SJP), Brazil
| | - M A Bottino
- Marco Antonio Bottino, DDs, MSc, PhD, professor, São Paulo State University (UNESP/SJP), Brazil
| | - M Özcan
- Mutlu Özcan, DDs, MSc, PhD, professor, University of Zurich, Switzerland
| | - Y Zhang
- Yu Zhang, DDs, MSc, PhD, professor, University of Pennsylvania, Philadelphia, PA
| | - Roa Souza
- *Rodrigo Othavio Assunção Souza, DDS, MSc, PhD, professor, Federal University of Rio Grande do Norte (UFRN), Brazil
| |
Collapse
|
6
|
Shihabi S, Chrcanovic BR. Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:5755-5769. [PMID: 37626273 PMCID: PMC10560185 DOI: 10.1007/s00784-023-05219-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 08/15/2023] [Indexed: 08/27/2023]
Abstract
PURPOSE To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia (PVZ) fixed dental prosthesis, based on a systematic literature review. METHODS An electronic search was performed in three databases, supplemented by hand searching. Several statistical methods were used. RESULTS Seventy-four publications reported 6370 restorations (4264 PVZ; 2106 MZ; 8200 abutment teeth; 3549 patients), followed up until 152 months. A total of 216 prostheses failed, and survival was statistically significant different between groups. PVZ had higher occurrence of complications than MZ; the difference was especially greater for either minor or major chipping. The difference in prevalence of either minor or major chipping was statistically significant for PVZ prostheses between cementation with glass ionomer and adhesive resin cement (higher), adhesive resin and resin-modified glass ionomer cement (RMGIC, higher), and between RMGIC (higher) and glass ionomer cement. For MZ the difference was significant only for minor chipping between RMGIC (higher) and adhesive resin cement. Abutment teeth to PVZ prostheses more often lost vitality. Decementation was not observed with RMGIC. Air abrasion did not seem to clinically decrease the decementation risk. The 5-year difference in the occurrence of minor or major chipping between MZ and PVZ prostheses was statistically significant, but nor for catastrophic fracture. CONCLUSION Tooth-supported PVZ prostheses present higher failure and complication rates than MZ prosthesis. The difference in complications is striking when it comes to chipping. CLINICAL RELEVANCE Awareness of the outcome differences between different types of zirconia prostheses is important for clinical practice.
Collapse
Affiliation(s)
| | - Bruno Ramos Chrcanovic
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21 Malmö, Sweden
| |
Collapse
|
7
|
Barile G, Capodiferro S, Muci G, Carnevale A, Albanese G, Rapone B, Corsalini M. Clinical Outcomes of Monolithic Zirconia Crowns on Posterior Natural Abutments Performed by Final Year Dental Medicine Students: A Prospective Study with a 5-Year Follow-Up. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:2943. [PMID: 36833639 PMCID: PMC9966316 DOI: 10.3390/ijerph20042943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/03/2023] [Accepted: 02/05/2023] [Indexed: 06/18/2023]
Abstract
The conventional metal-ceramic is still considered the gold standard in fixed prosthetics especially in terms of longevity. Among alternative materials used, Monolithic Zirconia has shown the capability to reconcile excellent biomechanical properties with acceptable aesthetic performance and to overcome several inconveniences related to veneer restorations. This study aims to clinically evaluate Monolithic Zirconia prosthetic crowns on natural abutments in the posterior sectors, performed by final-year dental medicine students (undoubtedly with less experience in the management of such material) by the standardized California Dental Association score system evaluation, to better understand the viability of Monolithic Zirconia. This prospective study was carried out at the Dental School of the University of Bari "Aldo Moro", Italy. Prosthetic rehabilitation included single crowns or a short pontic prosthesis with maximum one intermediate. Final-year dental students performed tooth reduction under the supervision of three expert tutors. The California Dental Association systematics (based on color, surface, anatomical shape, and marginal integrity) were adopted to evaluate the prosthetic maintenance status over time. Annual follow-up visits were re-evaluated by the same parameters each year. Univariate logistic regression analysis was performed to evaluate outcomes and the Kaplan-Meier plot to report survival. The sample consists of 40 crowns performed on 31 patients, 15 males (48.4%) and 16 females (51.6%) with an average age of 59.3 years. The clinical cases subjected to experimental study were found to be "Excellent" (1a/2a/3a/4a) in 34 cases (85%), "Acceptable" in 4 cases (10%), and "To be re-done" in 2 cases (failures) (5%). Our conclusive data support the predictability of Monolithic Zirconia restorations on natural posterior abutments at a long-term follow-up of five years, even when performed by less-experienced clinicians.
Collapse
Affiliation(s)
- Giuseppe Barile
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Saverio Capodiferro
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Giovannino Muci
- Dental School, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | | | - Giovanni Albanese
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Biagio Rapone
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Massimo Corsalini
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| |
Collapse
|
8
|
Valenti M, Valenti A, Schmitz JH, Cortellini D, Canale A. Survival analysis up to 7 years of 621 zirconia monolithic single crowns with feather-edge margins fabricated with a cast-free workflow starting from intraoral scans: A multicentric retrospective study. J Prosthet Dent 2023; 129:76-82. [PMID: 35850872 DOI: 10.1016/j.prosdent.2022.05.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 05/12/2022] [Accepted: 05/13/2022] [Indexed: 01/18/2023]
Abstract
STATEMENT OF PROBLEM Clinical studies on the fabrication of monolithic zirconia restorations with a feather-edge tooth preparation from digital scans and a cast-free fully digital workflow are lacking. PURPOSE The purpose of this retrospective multicentric study in private practices was to evaluate the outcomes of monolithic zirconia crowns fabricated with feather-edge margins and a cast-free approach. MATERIAL AND METHODS A total of 621 teeth were prepared with feather-edge margins and restored with monolithic zirconia crowns fabricated with a fully digital cast-free workflow. Data were analyzed by using the Kaplan-Meier test and descriptive statistics. The clinical evaluation adopted the California Dental Association-modified criteria after recalling all patients between April and July 2021. RESULTS The clinical survival of 619 of 621 crowns, including recemented crowns placed in 427 patients (217 men, 220 women) over 5 years (2014 to 2019 with crowns in service between 12 and 85 months), was analyzed. The 2 excluded crowns were delivered to patients who dropped out of the study. Of the 619 crowns, 5 failed during the follow-up period: 4 teeth were extracted because of fracture and 1 restoration fractured. No other technical or biological failures were observed. The mean overall survival time was 84.4 months (standard error, 0.255; 95% confidence interval for the mean, 83.92 to 84.92). The overall survival probability was 99.1% up to 85 months. CONCLUSIONS The clinical outcomes of the monolithic zirconia crowns with feather-edge margins evaluated were comparable with outcomes reported using other margin designs and materials.
Collapse
|
9
|
Multilayer Super-Translucent Zirconia for Chairside Fabrication of a Monolithic Posterior Crown. Case Rep Dent 2022; 2022:4474227. [PMID: 35371572 PMCID: PMC8967591 DOI: 10.1155/2022/4474227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 03/07/2022] [Indexed: 11/17/2022] Open
Abstract
This case report describes the chairside fabrication of a monolithic posterior crown using a multilayer super-translucent zirconia material. According to the manufacturer’s information, the newly introduced multilayer zirconia (4-YTZP) offers a unique combination of fracture strength (>850 MPa with speed-sintering) and improved optical properties, thus allowing a reduced minimum material thickness and optional temporary luting. By using up-to-date components of the CEREC system, including superfast dry-milling and a speed-sintering process, the fabrication of a monolithic zirconia crown is possible within an acceptable timeframe for the chairside workflow (60-75 min). The usage of a multilayer super-translucent material allows for the individualization of the restoration, typically in a single combined stain and glaze firing. However, it should be noted that clinical data for this type of restoration are still sparse. Therefore, manufacturer recommendations regarding indication, preparation, and cementation must be followed very strictly.
Collapse
|