1
|
Drabczyk A, Ciężkowska M, Kałahurska K, Zięba A, Bulowski W, Bucka K, Kasza P, Zbroja K, Putynkowski G, Socha RP. The Application of Ultrasound Pre-Treatment in Low-Temperature Synthesis of Zinc Oxide Nanorods. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4980. [PMID: 39459685 PMCID: PMC11509445 DOI: 10.3390/ma17204980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 09/30/2024] [Accepted: 10/10/2024] [Indexed: 10/28/2024]
Abstract
Zinc oxide, due to its unique physicochemical properties, including dual piezoelectric and semiconductive ones, demonstrates a high application potential in various fields, with a particular focus on nanotechnology. Among ZnO nanoforms, nanorods are gaining particular interest. Due to their ability to efficiently transport charge carriers and photoelectric properties, they demonstrate significant potential in energy storage and conversion, as well as photovoltaics. They can be prepared via various methods; however, most of them require large energy inputs, long reaction times, or high-cost equipment. Hence, new methods of ZnO nanorod fabrication are currently being sought out. In this paper, an ultrasound-supported synthesis of ZnO nanorods with zinc acetate as a zinc precursor has been described. The fabrication of nanorods included the treatment of the precursor solution with ultrasounds, wherein various sonication times were employed to verify the impact of the sonication process on the effectiveness of ZnO nanorod synthesis and the sizes of the obtained nanostructures. The morphology of the obtained ZnO nanorods was imaged via a scanning electron microscope (SEM) analysis, while the particle size distribution within the precursor suspensions was determined by means of dynamic light scattering (DLS). Additionally, the dynamic viscosity of precursor suspensions was also verified. It was demonstrated that ultrasounds positively affect ZnO nanorod synthesis, yielding longer nanostructures through even reactant distribution. Longer nanorods were obtained as a result of short sonication (1-3 min), wherein prolonged treatment with ultrasounds (4-5 min) resulted in obtaining shorter nanorods. Importantly, the application of ultrasounds increased particle homogeneity within the precursor suspension by disintegrating particle agglomerates. Moreover, it was demonstrated that ultrasonic treatment reduces the dynamic viscosity of precursor suspension, facilitating faster particle diffusion and promoting a more uniform growth of longer ZnO nanorods. Hence, it can be concluded that ultrasounds constitute a promising solution in obtaining homogeneous ZnO nanorods, which is in line with the principles of green chemistry.
Collapse
Affiliation(s)
- Anna Drabczyk
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Magda Ciężkowska
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Katarzyna Kałahurska
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Adam Zięba
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Wojciech Bulowski
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
- Faculty of Non-Ferrous Metals, AGH University of Krakow, Al. Mickiewicza 30, 30-059 Kraków, Poland
| | - Katarzyna Bucka
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
- Faculty of Non-Ferrous Metals, AGH University of Krakow, Al. Mickiewicza 30, 30-059 Kraków, Poland
| | - Patryk Kasza
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Krzysztof Zbroja
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Grzegorz Putynkowski
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| | - Robert P. Socha
- CBRTP SA—Research and Development Center of Technology for Industry, 3A Ludwika Waryńskiego St., 00-645 Warsaw, Poland; (M.C.); (K.K.); (A.Z.); (W.B.); (K.B.); (P.K.); (K.Z.); (G.P.)
| |
Collapse
|
2
|
Yang JC, Shin N, Lim SJ, Cho CH, Hazarika D, Park JP, Park J. Molecularly imprinted polymer-based extended-gate field-effect transistor chemosensors for selective determination of antiepileptic drug. Mikrochim Acta 2024; 191:400. [PMID: 38879615 DOI: 10.1007/s00604-024-06487-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 06/04/2024] [Indexed: 06/22/2024]
Abstract
Ultrathin molecularly imprinted polymer (MIP) films were deposited on the surfaces of ZnO nanorods (ZNRs) and nanosheets (ZNSs) by electropolymerization to afford extended-gate field-effect transistor sensors for detecting phenytoin (PHT) in plasma. Molecular imprinting efficiency was optimized by controlling the contents of functional monomers and the template in the precursor solution. PHT sensing was performed in plasma solutions with various concentrations by monitoring the drain current as a function of drain voltage under an applied gate voltage of 1.5 V. The reliability and reproducibility of the fabricated sensors were evaluated through a solution treatment process for complete PHT removal and PHT adsorption-removal cycling, while selectivity was examined by analyzing responses to chemicals with structures analogous to that of PHT. Compared with the ZNS/extracted-MIP sensor and sensors with non-imprinted polymer (NIP) films, the ZNR/extracted-MIP sensor showed superior responses to PHT-containing plasma due to selective PHT adsorption, achieving an imprinting factor of 4.23, detection limit of 12.9 ng/mL, quantitation limit of 53.0 ng/mL, and selectivity coefficients of 3-4 (against tramadol) and ~ 5 (against diphenhydramine). Therefore, we believe that the MIP-based ZNR sensing platform is promising for the practical detection of PHT and other drugs and evaluation of their proper dosages.
Collapse
Affiliation(s)
- Jin Chul Yang
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-Ro, Daegu, 41566, Republic of Korea
| | - Nari Shin
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-Ro, Daegu, 41566, Republic of Korea
| | - Seok Jin Lim
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-Ro, Daegu, 41566, Republic of Korea
| | - Chae Hwan Cho
- Department of Food Science and Technology, and GreenTech-based Food Safety Research Group, BK21 Four, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Deepshikha Hazarika
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-Ro, Daegu, 41566, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, and GreenTech-based Food Safety Research Group, BK21 Four, Chung-Ang University, Anseong, 17546, Republic of Korea.
| | - Jinyoung Park
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-Ro, Daegu, 41566, Republic of Korea.
| |
Collapse
|
3
|
de Godoy HA, Faria AM, Roza NAV, Bach-Toledo L, Simabuco FM, Scharlack NK, de Oliveira RB, Antunes AEC, Arthur R, Mazon T. Point-of-Care Electrochemical Immunosensor Applied against Nosocomial Infection: Staphylococcus aureus Detection in Human Hand Skin. ACS Infect Dis 2024; 10:1949-1957. [PMID: 38741263 DOI: 10.1021/acsinfecdis.3c00603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
Staphylococcus aureus is an important pathogen that causes nosocomial infections, resulting in unacceptable morbidity and mortality rates. In this work, we proposed the construction of a nanostructured ZnO-based electrochemical immunosensor for qualitative and semiquantitative detection of S. aureus using simple methods for growing zinc oxide nanorods (ZnO NRs) on a sensor board and immobilizing the anti-S. aureus antibody on ZnO NRs through cystamine and glutaraldehyde. The immunosensor detected S. aureus in the 103-107 colony-forming unit (CFU) mL-1 range and showed a limit of detection (LoD) around 0.792 × 103 CFU mL-1. Beyond a satisfactory LoD, the developed immunosensor presented other advantages, such as high versatility for point-of-care assays and a suitable selective factor that admits the detection of the S. aureus concentration range in human hand skin after washing. Moreover, the immunosensor showed the potential to be an excellent device to control nosocomial infection by detecting the presence of S. aureus in human hand skin.
Collapse
Affiliation(s)
- Henri Alves de Godoy
- School of Technology, State University of Campinas (UNICAMP), 13484-332 Limeira, SP, Brazil
| | - Aline Macedo Faria
- Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil
| | | | - Larissa Bach-Toledo
- Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil
| | | | - Nayara Kastem Scharlack
- School of Applied Sciences, State University of Campinas (UNICAMP), 13484-350 Limeira, SP, Brazil
| | | | | | - Rangel Arthur
- School of Technology, State University of Campinas (UNICAMP), 13484-332 Limeira, SP, Brazil
| | - Talita Mazon
- Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil
| |
Collapse
|
4
|
Brasiunas B, Popov A, Lisyte V, Kausaite-Minkstimiene A, Ramanaviciene A. ZnO nanostructures: A promising frontier in immunosensor development. Biosens Bioelectron 2024; 246:115848. [PMID: 38042053 DOI: 10.1016/j.bios.2023.115848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 11/01/2023] [Accepted: 11/15/2023] [Indexed: 12/04/2023]
Abstract
This review addresses the design of immunosensors, which employ ZnO nanostructures. Various methods of modifying ZnO nanostructures with antibodies or antigens are discussed, including covalent and non-covalent approaches and cross-linking techniques. Immunosensors based on different properties of ZnO nanomaterials are described and compared. This article provides a comprehensive review of electrochemical immunosensors based on ZnO nanostructures and various detection techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), photoelectrochemical (PEC) detection, electrochemical impedance spectroscopy (EIS), and other electrochemical methods. In addition, this review article examines the application of optical detection techniques, including photoluminescence (PL) and electrochemiluminescence (ECL), in the development of immunosensors based on ZnO nanostructures.
Collapse
Affiliation(s)
- Benediktas Brasiunas
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Anton Popov
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Viktorija Lisyte
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Asta Kausaite-Minkstimiene
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Almira Ramanaviciene
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania.
| |
Collapse
|
5
|
Kannan P, Maduraiveeran G. Metal Oxides Nanomaterials and Nanocomposite-Based Electrochemical Sensors for Healthcare Applications. BIOSENSORS 2023; 13:bios13050542. [PMID: 37232903 DOI: 10.3390/bios13050542] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/17/2023] [Accepted: 05/09/2023] [Indexed: 05/27/2023]
Abstract
Wide-ranging research efforts have been directed to prioritize scientific and technological inventions for healthcare monitoring. In recent years, the effective utilization of functional nanomaterials in various electroanalytical measurements realized a rapid, sensitive, and selective detection and monitoring of a wide range of biomarkers in body fluids. Owing to good biocompatibility, high organic capturing ability, strong electrocatalytic activity, and high robustness, transition metal oxide-derived nanocomposites have led to enhancements in sensing performances. The aim of the present review is to describe key advancements of transition metal oxide nanomaterials and nanocomposites-based electrochemical sensors, along with current challenges and prospects towards the development of a highly durable and reliable detection of biomarkers. Moreover, the preparation of nanomaterials, electrode fabrication, sensing mechanism, electrode-bio interface, and performance of metal oxides nanomaterials and nanocomposite-based sensor platforms will be described.
Collapse
Affiliation(s)
- Palanisamy Kannan
- College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China
| | - Govindhan Maduraiveeran
- Materials Electrochemistry Laboratory, Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur 603 203, Tamil Nadu, India
| |
Collapse
|
6
|
Beig B, Niazi MBK, Jahan Z, Haider G, Zia M, Shah GA, Iqbal Z, Hayat A. Development and testing of zinc sulfate and zinc oxide nanoparticle-coated urea fertilizer to improve N and Zn use efficiency. FRONTIERS IN PLANT SCIENCE 2023; 13:1058219. [PMID: 36733597 PMCID: PMC9886897 DOI: 10.3389/fpls.2022.1058219] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 12/19/2022] [Indexed: 06/18/2023]
Abstract
Nitrogen (N) losses from conventional fertilizers in agricultural systems are very high, which can lead to serious environmental pollution with economic loss. In this study, innovative slow-release fertilizers were prepared using zinc (Zn) [nanoparticles (NPs) or in bulk], using molasses as an environmentally friendly coating. Several treatments were prepared using Zn in different concentrations (i.e., 0.25%, 0.5%, and 4% elemental Zn). The zinc oxide nanoparticles (ZnO-NPs) were prepared from zinc sulfate heptahydrate (ZnSO4·7H2O), and were characterized using scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier transform infrared (FTIR) spectroscopy. Furthermore, the Zn-loaded urea samples were tested for urea N release rate, leaching of water from soil, and crushing strength to assess the impact of coating on the final finished product. Pot experiments were conducted simultaneously to check the agronomic effects of Zn-coated slow-release urea on the growth and development of wheat (Triticum aestivum L.). The laboratory and pot results confirmed that the ZnO-NP treatments boost wheat growth and yield as a result of reduced N and Zn release. UZnNPs2 (urea coated with 0.5% ZnO-NPs and 5% molasses) demonstrated the best results among all the treatments in terms of slow nutrient release, N and Zn uptake, and grain yield. The UZnNPs2 treatment increased plant yield by 34% (i.e., 4,515 vs. 3,345 kg ha-1) relative to the uncoated prill-treated crop because of the slower release of Zn and N.
Collapse
Affiliation(s)
- Bilal Beig
- Department of Chemical Engineering, School of Chemical and Materials Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Muhammad Bilal Khan Niazi
- Department of Chemical Engineering, School of Chemical and Materials Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Zaib Jahan
- Department of Chemical Engineering, School of Chemical and Materials Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Ghulam Haider
- Department of Plant Biotechnology, Atta-Ur-Rahman School of Applied Biosciences, National University of Sciences and Technology, Islamabad, Pakistan
| | - Munir Zia
- Research and Development Department, Fauji Fertilizer Company Limited, Rawalpindi, Pakistan
| | - Ghulam Abbas Shah
- Department of Agronomy, Pir Mehr Ali Shah Arid Agriculture University Rawalpindi-Arid Agriculture University, Rawalpindi, Punjab, Pakistan
| | - Zahid Iqbal
- Department of Chemical Engineering, School of Chemical and Materials Engineering, National University of Sciences and Technology, Islamabad, Pakistan
- Institute of Soil and Environmental Sciences, Pir Mehr Ali Shah Arid Agriculture University Rawalpindi-Arid Agriculture University, Rawalpindi, Punjab, Pakistan
| | - Asim Hayat
- Land Resources Research Institute (LRRI), National Agricultural Research Center, Islamabad, Pakistan
| |
Collapse
|
7
|
Nunez FA, Castro ACH, de Oliveira VL, Lima AC, Oliveira JR, de Medeiros GX, Sasahara GL, Santos KS, Lanfredi AJC, Alves WA. Electrochemical Immunosensors Based on Zinc Oxide Nanorods for Detection of Antibodies Against SARS-CoV-2 Spike Protein in Convalescent and Vaccinated Individuals. ACS Biomater Sci Eng 2023; 9:458-473. [PMID: 36048716 PMCID: PMC9469957 DOI: 10.1021/acsbiomaterials.2c00509] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 08/24/2022] [Indexed: 01/11/2023]
Abstract
Even after over 2 years of the COVID-19 pandemic, research on rapid, inexpensive, and accurate tests remains essential for controlling and avoiding the global spread of SARS-CoV-2 across the planet during a potential reappearance in future global waves or regional outbreaks. Assessment of serological responses for COVID-19 can be beneficial for population-level surveillance purposes, supporting the development of novel vaccines and evaluating the efficacy of different immunization programs. This can be especially relevant for broadly used inactivated whole virus vaccines, such as CoronaVac, which produced lower titers of neutralizing antibodies. and showed lower efficacy for specific groups such as the elderly and immunocompromised. We developed an impedimetric biosensor based on the immobilization of SARS-CoV-2 recombinant trimeric spike protein (S protein) on zinc oxide nanorod (ZnONR)-modified fluorine-doped tin oxide substrates for COVID-19 serology testing. Due to electrostatic interactions, the negatively charged S protein was immobilized via physical adsorption. The electrochemical response of the immunosensor was measured at each modification step and characterized by scanning electron microscopy and electrochemical techniques. We successfully evaluated the applicability of the modified ZnONR electrodes using serum samples from COVID-19 convalescent individuals, CoronaVac-vaccinated with or without positive results for SARS-CoV-2 infection, and pre-pandemic samples from healthy volunteers as controls. ELISA for IgG anti-SARS-CoV-2 spike protein was performed for comparison, and ELISA for IgG anti-RBDs of seasonal coronavirus (HCoVs) was used to test the specificity of immunosensor detection. No cross-reactivity with HCoVs was detected using the ZnONR immunosensor, and more interestingly, the sensor presented higher sensitivity when compared to negative ELISA results. The results demonstrate that the ZnONRs/spike-modified electrode displayed sensitive results for convalescents and vaccinated samples and shows excellent potential as a tool for the population's assessment and monitoring of seroconversion and seroprevalence.
Collapse
Affiliation(s)
- Freddy A. Nunez
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| | - Ana C. H. Castro
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| | - Vivian L. de Oliveira
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
| | - Ariane C. Lima
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Jamille R. Oliveira
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Giuliana X. de Medeiros
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Greyce L. Sasahara
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
| | - Keity S. Santos
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Alexandre J. C. Lanfredi
- Centro de Engenharia, Modelagem e Ciências
Sociais Aplicadas, Universidade Federal do ABC, Av. dos
Estados, 5001, Santo André, São Paulo09210-580,
Brazil
| | - Wendel A. Alves
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| |
Collapse
|
8
|
Maciulis V, Ramanaviciene A, Plikusiene I. Recent Advances in Synthesis and Application of Metal Oxide Nanostructures in Chemical Sensors and Biosensors. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:nano12244413. [PMID: 36558266 PMCID: PMC9783830 DOI: 10.3390/nano12244413] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/06/2022] [Accepted: 12/07/2022] [Indexed: 05/31/2023]
Abstract
Nanostructured materials formed from metal oxides offer a number of advantages, such as large surface area, improved mechanical and other physical properties, as well as adjustable electronic properties that are important in the development and application of chemical sensors and biosensor design. Nanostructures are classified using the dimensions of the nanostructure itself and their components. In this review, various types of nanostructures classified as 0D, 1D, 2D, and 3D that were successfully applied in chemical sensors and biosensors, and formed from metal oxides using different synthesis methods, are discussed. In particular, significant attention is paid to detailed analysis and future prospects of the synthesis methods of metal oxide nanostructures and their integration in chemical sensors and biosensor design.
Collapse
Affiliation(s)
- Vincentas Maciulis
- State Research Institute Centre for Physical Sciences and Technology, Sauletekio Ave. 3, LT-10257 Vilnius, Lithuania
- Nanotechnas–Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Almira Ramanaviciene
- Nanotechnas–Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Ieva Plikusiene
- State Research Institute Centre for Physical Sciences and Technology, Sauletekio Ave. 3, LT-10257 Vilnius, Lithuania
- Nanotechnas–Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| |
Collapse
|
9
|
Patella B, Narayan T, O'Sullivan B, Daly R, Zanca C, Lovera P, Inguanta R, O'Riordan A. Simultaneous detection of copper and mercury in water samples using in-situ pH control with electrochemical stripping techniques. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
10
|
Behavior of Calcium Phosphate-Chitosan-Collagen Composite Coating on AISI 304 for Orthopedic Applications. Polymers (Basel) 2022; 14:polym14235108. [PMID: 36501503 PMCID: PMC9735702 DOI: 10.3390/polym14235108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/19/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022] Open
Abstract
Calcium phosphate/chitosan/collagen composite coating on AISI 304 stainless steel was investigated. Coatings were realized by galvanic coupling that occurs without an external power supply because it begins with the coupling between two metals with different standard electrochemical potentials. The process consists of the co-deposition of the three components with the calcium phosphate crystals incorporated into the polymeric composite of chitosan and collagen. Physical-chemical characterizations of the samples were executed to evaluate morphology and chemical composition. Morphological analyses have shown that the surface of the stainless steel is covered by the deposit, which has a very rough surface. XRD, Raman, and FTIR characterizations highlighted the presence of both calcium phosphate compounds and polymers. The coatings undergo a profound variation after aging in simulated body fluid, both in terms of composition and structure. The tests, carried out in simulated body fluid to scrutinize the corrosion resistance, have shown the protective behavior of the coating. In particular, the corrosion potential moved toward higher values with respect to uncoated steel, while the corrosion current density decreased. This good behavior was further confirmed by the very low quantification of the metal ions (practically absent) released in simulated body fluid during aging. Cytotoxicity tests using a pre-osteoblasts MC3T3-E1 cell line were also performed that attest the biocompatibility of the coating.
Collapse
|
11
|
Patella B, Vincenzo SD, Zanca C, Bollaci L, Ferraro M, Giuffrè MR, Cipollina C, Bruno MG, Aiello G, Russo M, Inguanta R, Pace E. Electrochemical Quantification of H 2O 2 Released by Airway Cells Growing in Different Culture Media. MICROMACHINES 2022; 13:1762. [PMID: 36296115 PMCID: PMC9611932 DOI: 10.3390/mi13101762] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/11/2022] [Accepted: 10/12/2022] [Indexed: 05/30/2023]
Abstract
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham's F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrodeposition. To reduce the electrode fouling by the medium, the effect of dilution was investigated using diluted (50% v/v in PBS) and undiluted media. With the same aim, two electrochemical techniques were employed, chronoamperometry (CH) and linear scan voltammetry (LSV). The influence of different interfering species and the effect of the operating temperature of 37 °C were also studied in order to simulate the operation of the sensor in the culture plate. The LSV technique made the sensor adaptable to undiluted media because the test time is short, compared with the CH technique, reducing the electrode fouling. The long-term stability of the sensors was also evaluated by testing different storage conditions. By storing the electrode at 4 °C, the sensor performance was not reduced for up to 21 days. The sensors were validated measuring H2O2 released by two different human bronchial epithelial cell lines (A549, 16HBE) and human primary bronchial epithelial cells (PBEC) grown in RPMI, MEM and BEGM/DMEM media. To confirm the results obtained with the sensor, the release of reactive oxygen species was also evaluated with a standard flow cytometry technique. The results obtained with the two techniques were very similar. Thus, the LSV technique permits using the proposed sensor for an effective oxidative stress quantification in different culture media and without dilution.
Collapse
Affiliation(s)
- Bernardo Patella
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Serena Di Vincenzo
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | - Claudio Zanca
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Luciano Bollaci
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Maria Ferraro
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | | | - Chiara Cipollina
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
- Ri.MED Foundation, 90146 Palermo, Italy
| | | | - Giuseppe Aiello
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | | | | | - Elisabetta Pace
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| |
Collapse
|