1
|
Mane S, Behera A, Hemadri V, Bhand S, Tripathi S. Micropump integrated white blood cell separation platform for detection of chronic granulomatous disease. Mikrochim Acta 2024; 191:295. [PMID: 38700804 DOI: 10.1007/s00604-024-06372-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 04/18/2024] [Indexed: 05/05/2024]
Abstract
White blood cells (WBCs) are robust defenders during antigenic challenges and prime immune cell functioning indicators. High-purity WBC separation is vital for various clinical assays and disease diagnosis. Red blood cells (RBCs) are a major hindrance in WBC separation, constituting 1000 times the WBC population. The study showcases a low-cost micropump integrated microfluidic platform to provide highly purified WBCs for point-of-care testing. An integrated user-friendly microfluidic platform was designed to separate WBCs from finger-prick blood (⁓5 μL), employing an inertial focusing technique. We achieved an efficient WBC separation with 86% WBC purity and 99.99% RBC removal rate in less than 1 min. In addition, the microdevice allows lab-on-chip colorimetric evaluation of chronic granulomatous disease (CGD), a rare genetic disorder affecting globally. The assay duration, straight from separation to disease detection, requires only 20 min. Hence, the proposed microfluidic platform can further be implemented to streamline various clinical procedures involving WBCs in healthcare industries.
Collapse
Affiliation(s)
- Sanjay Mane
- Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India
| | - Abhishek Behera
- Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India
| | - Vadiraj Hemadri
- Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India
| | - Sunil Bhand
- Department of Chemistry, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India
| | - Siddhartha Tripathi
- Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Sankval, Goa, 403726, India.
| |
Collapse
|
2
|
Wan TY, Hwa HL, Lee TT, Lu YW. High efficiency sperm enrichment from forensic mock samples in bubble-based acoustic filtration devices for short tandem repeat (STR) analysis. LAB ON A CHIP 2024; 24:434-445. [PMID: 38086663 DOI: 10.1039/d3lc00632h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
A bubble-based acoustofluidic filtration (BAF) microfluidic device, which employs cross-flow filtration (CFF) and acoustic streaming, separates cells with high efficiency for forensic analysis. Forensic samples are typically complex and contain a substantial number of squamous epithelial cells from the female vagina, which tend to have fouling problems during filtration due to their morphological and cell adhesion differences. To overcome this issue, the BAF device utilizes bubble oscillation by bulk acoustic wave (BAW) to generate acoustic streaming, which offers additional hydrodynamic forces for side flushing cleaning and achieves effective removal within a mere 0.5 seconds. Our device is tested with imbalanced cell mixtures of sperm and epithelial cells with large disparity ratios. By concurrently employing CFF and acoustic streaming, the samples with our sperm-enrichment can achieve 91.72-97.78% for the recovery rate and 74.58-89.26% for the purity in the sperm enrichment. They are further subjected to short tandem repeat (STR) profiling, enabling the identification of perpetrators. Notably, even samples with minimal sperm cells demonstrated a significant increase in the male donor DNA ratio, while the peak heights of female alleles became virtually undetectable. The exceptional cell separation capability demonstrated by our BAF device highlights its potential applications in forensic sciences and other areas of cell biology.
Collapse
Affiliation(s)
- Ting-Yu Wan
- Department of Biomechatronics Engineering, National Taiwan University, Taipei, Taiwan.
| | - Hsiao-Lin Hwa
- Graduate Institute of Forensic Medicine, National Taiwan University, Taipei, Taiwan
| | - Tsui-Ting Lee
- Graduate Institute of Forensic Medicine, National Taiwan University, Taipei, Taiwan
| | - Yen-Wen Lu
- Department of Biomechatronics Engineering, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
3
|
Fu Y, Hong HJ, Venault A, Chang Y. Thermo-responsive bioseparation engineered for human leukocyte enrichment process driven by functionalized polypropylene bio-separators. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.121014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
4
|
Separation of White Blood Cells in a Wavy Type Microfluidic Device Using Blood Diluted in a Hypertonic Saline Solution. BIOCHIP JOURNAL 2022. [DOI: 10.1007/s13206-022-00074-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
5
|
Szittner Z, Péter B, Kurunczi S, Székács I, Horváth R. Functional blood cell analysis by label-free biosensors and single-cell technologies. Adv Colloid Interface Sci 2022; 308:102727. [DOI: 10.1016/j.cis.2022.102727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/25/2022] [Accepted: 06/27/2022] [Indexed: 11/01/2022]
|
6
|
Xu X, Huang X, Sun J, Wang R, Yao J, Han W, Wei M, Chen J, Guo J, Sun L, Yin M. Recent progress of inertial microfluidic-based cell separation. Analyst 2021; 146:7070-7086. [PMID: 34761757 DOI: 10.1039/d1an01160j] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cell separation has consistently been a pivotal technology of sample preparation in biomedical research. Compared with conventional bulky cell separation technologies applied in the clinic, cell separation based on microfluidics can accurately manipulate the displacement of liquid or cells at the microscale, which has great potential in point-of-care testing (POCT) applications due to small device size, low cost, low sample consumption, and high operating accuracy. Among various microfluidic cell separation technologies, inertial microfluidics has attracted great attention due to its simple structure and high throughput. In recent years, many researchers have explored the principles and applications of inertial microfluidics and developed different channel structures, including straight channels, curved channels, and multistage channels. However, the recently developed multistage channels have not been discussed and classified in detail compared with more widely discussed straight and curved channels. Therefore, in this review, a comprehensive and detailed review of recent progress in the multistage channel is presented. According to the channel structure, the inertial microfluidic separation technology is divided into (i) straight channel, (ii) curved channel, (iii) composite channel, and (iv) integrated device. The structural development of straight and curved channels is discussed in detail. And based on straight and curved channels, the multistage cell separation structures are reviewed, with a special focus on a variety of latest structures and related innovations of composite and integrated channels. Finally, the future prospects for the existing challenges in the development of inertial microfluidic cell separation technology are presented.
Collapse
Affiliation(s)
- Xuefeng Xu
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Xiwei Huang
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Jingjing Sun
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Renjie Wang
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Jiangfan Yao
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Wentao Han
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Maoyu Wei
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Jin Chen
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Jinhong Guo
- School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Lingling Sun
- Key Laboratory of RF Circuits and Systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Ming Yin
- The Second Medical Center and National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing 100853, China.
| |
Collapse
|
7
|
Narayana Iyengar S, Kumar T, Mårtensson G, Russom A. High resolution and rapid separation of bacteria from blood using elasto-inertial microfluidics. Electrophoresis 2021; 42:2538-2551. [PMID: 34510466 DOI: 10.1002/elps.202100140] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/27/2021] [Accepted: 09/06/2021] [Indexed: 12/13/2022]
Abstract
Improved sample preparation has the potential to address unmet needs for fast turnaround sepsis tests. In this work, we report elasto-inertial based rapid bacteria separation from diluted blood at high separation efficiency. In viscoelastic flows, we demonstrate novel findings where blood cells prepositioned at the outer wall entering a spiral device remain fully focused throughout the channel length while smaller bacteria migrate to the opposite wall. Initially, using microparticles, we show that particles above a certain size cut-off remain fully focused at the outer wall while smaller particles differentially migrate toward the inner wall. We demonstrate particle separation at 1 μm resolution at a total throughput of 1 mL/min. For blood-based experiments, a minimum of 1:2 dilution was necessary to fully focus blood cells at the outer wall. Finally, Escherichia coli spiked in diluted blood were continuously separated at a total flow rate of 1 mL/min, with efficiencies between 82 and 90% depending on the blood dilution. Using a single spiral, it takes 40 min to process 1 mL of blood at a separation efficiency of 82%. The label-free, passive, and rapid bacteria isolation method has a great potential for speeding up downstream phenotypic and genotypic analysis.
Collapse
Affiliation(s)
- Sharath Narayana Iyengar
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| | - Tharagan Kumar
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| | - Gustaf Mårtensson
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden
| | - Aman Russom
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
8
|
Lu X, Tayebi M, Ai Y. A low-cost and high-throughput benchtop cell sorter for isolating white blood cells from whole blood. Electrophoresis 2021; 42:2281-2292. [PMID: 34010478 DOI: 10.1002/elps.202100024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 05/10/2021] [Accepted: 05/16/2021] [Indexed: 11/07/2022]
Abstract
The ability to isolate and purify white blood cells (WBCs) from mixed ensembles such as blood would benefit autologous cell-based therapeutics as well as diagnosis of WBC disorders. Current WBCs isolation methods have the limitations of low purity or requiring complex and expensive equipment. In addition, due to the overlap in size distribution between lymphocytes (i.e., a sub-population of WBCs) and red blood cells (RBCs), it is challenging to achieve isolation of entire WBCs populations. In this work, we developed an inertial microfluidics-based cell sorter, which enables size-based, high-throughput isolation, and enrichment of WBCs from RBC-lysed whole blood. Using the developed inertial microfluidic chip, the sorting resolution is sharpened within 2 μm, which achieved separation between 3 and 5 μm diameter particles. Thus, with the present cell sorter, a full population of WBCs can be isolated from RBC-lysed blood samples with recovery ratio of 92%, and merely 5% difference in the composition percentage of the three subpopulations of granulocytes, monocytes, and lymphocytes compared to the original sample. Furthermore, our cell sorter is designed to enable broad application of size-based inertial cell sorting by supplying a series of microchips with different sorting cutoff size. This strategy allows us to further enrich the lymphocytes population by twofold using another microchip with a cutoff size between 10 and 15 μm. With simplicity and efficiency, our cell sorter provides a powerful platform for isolating and sorting of WBCs and also envisions broad potential sorting applications for other cell types.
Collapse
Affiliation(s)
- Xiaoguang Lu
- Engineering Product Development, Singapore University of Technology and Design, Singapore
| | - Mahnoush Tayebi
- Engineering Product Development, Singapore University of Technology and Design, Singapore
| | - Ye Ai
- Engineering Product Development, Singapore University of Technology and Design, Singapore
| |
Collapse
|
9
|
High throughput viscoelastic particle focusing and separation in spiral microchannels. Sci Rep 2021; 11:8467. [PMID: 33875755 PMCID: PMC8055915 DOI: 10.1038/s41598-021-88047-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 04/07/2021] [Indexed: 12/17/2022] Open
Abstract
Passive particle manipulation using inertial and elasto-inertial microfluidics have received substantial interest in recent years and have found various applications in high throughput particle sorting and separation. For separation applications, elasto-inertial microfluidics has thus far been applied at substantial lower flow rates as compared to inertial microfluidics. In this work, we explore viscoelastic particle focusing and separation in spiral channels at two orders of magnitude higher Reynolds numbers than previously reported. We show that the balance between dominant inertial lift force, dean drag force and elastic force enables stable 3D particle focusing at dynamically high Reynolds numbers. Using a two-turn spiral, we show that particles, initially pinched towards the inner wall using an elasticity enhancer, PEO (polyethylene oxide), as sheath migrate towards the outer wall strictly based on size and can be effectively separated with high precision. As a proof of principle for high resolution particle separation, 15 µm particles were effectively separated from 10 µm particles. A separation efficiency of 98% for the 10 µm and 97% for the 15 µm particles was achieved. Furthermore, we demonstrate sheath-less, high throughput, separation using a novel integrated two-spiral device and achieved a separation efficiency of 89% for the 10 µm and 99% for the 15 µm particles at a sample flow rate of 1 mL/min—a throughput previously only reported for inertial microfluidics. We anticipate the ability to precisely control particles in 3D at extremely high flow rates will open up several applications, including the development of ultra-high throughput microflow cytometers and high-resolution separation of rare cells for point of care diagnostics.
Collapse
|
10
|
Tang W, Zhu S, Jiang D, Zhu L, Yang J, Xiang N. Channel innovations for inertial microfluidics. LAB ON A CHIP 2020; 20:3485-3502. [PMID: 32910129 DOI: 10.1039/d0lc00714e] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Inertial microfluidics has gained significant attention since first being proposed in 2007 owing to the advantages of simplicity, high throughput, precise manipulation, and freedom from an external field. Superior performance in particle focusing, filtering, concentrating, and separating has been demonstrated. As a passive technology, inertial microfluidics technology relies on the unconventional use of fluid inertia in an intermediate Reynolds number range to induce inertial migration and secondary flow, which depend directly on the channel structure, leading to particle migration to the lateral equilibrium position or trapping in a specific cavity. With the advances in micromachining technology, many channel structures have been designed and fabricated in the past decade to explore the fundamentals and applications of inertial microfluidics. However, the channel innovations for inertial microfluidics have not been discussed comprehensively. In this review, the inertial particle manipulations and underlying physics in conventional channels, including straight, spiral, sinusoidal, and expansion-contraction channels, are briefly described. Then, recent innovations in channel structure for inertial microfluidics, especially channel pattern modification and unconventional cross-sectional shape, are reviewed. Finally, the prospects for future channel innovations in inertial microfluidic chips are also discussed. The purpose of this review is to provide guidance for the continued study of innovative channel designs to improve further the accuracy and throughput of inertial microfluidics.
Collapse
Affiliation(s)
- Wenlai Tang
- School of Electrical and Automation Engineering, Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, Nanjing Normal University, Nanjing, 210023, China.
| | | | | | | | | | | |
Collapse
|