1
|
Rajamanikandan R, Sasikumar K, Ju H. β-Cyclodextrin Functionalized Au@Ag Core-Shell Nanoparticles: Plasmonic Sensors for Cysteamine and Efficient Nanocatalysts for Nitrobenzene-to-Aniline Conversion. BIOSENSORS 2024; 14:544. [PMID: 39590003 PMCID: PMC11591858 DOI: 10.3390/bios14110544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 11/06/2024] [Accepted: 11/07/2024] [Indexed: 11/28/2024]
Abstract
We reported the gold/silver core-shell nanoparticles (Aucore@Agshell NPs) functionalized with β-cyclodextrin (β-CD) as versatile nano-agents demonstrated for human urine-based biosensing of cysteamine and catalytic conversion from nitrobenzene (NB) to aniline. First, the hybrid bimetallic nanoparticles, i.e., β-CD-Aucore@Agshell NPs, constituted a colorimetric sensing platform based on localized surface plasmons, enabling cysteamine (Cyst) to be detected in a remarkably rapid manner, i.e., within 2 min, which was greatly shortened in comparison with that of our previous report. This was due largely to use of β-CD being effectively replaceable by Cyst. The detection of Cyst was demonstrated using human urine specimens in the linear range of 25-750 nM with a limit of detection of 1.83 nM. Excellent specificity in detecting Cyst was also demonstrated against potential interfering molecules. Meanwhile, the β-CD-Aucore@Agshell NPs were demonstrated as nanocatalysts for converting NB to aniline with efficiency enhanced by more than three-fold over the pure gold nanoparticles previously reported, due to the dual functions of the structural core-shell. The demonstrated versatile features of the hybrid nanoparticles can find applications in human urine-based biosensors for Cyst detection, and in the screening of Cyst-containing drugs, while detoxicating NB for ecological protection in aqueous media.
Collapse
Affiliation(s)
- Ramar Rajamanikandan
- Department of Physics, Gachon University, Seongnam-si 13120, Republic of Korea; (R.R.); (K.S.)
- Gachon Bionano Research Institute, Gachon University, Seongnam-si 13120, Republic of Korea
| | - Kandasamy Sasikumar
- Department of Physics, Gachon University, Seongnam-si 13120, Republic of Korea; (R.R.); (K.S.)
- Gachon Bionano Research Institute, Gachon University, Seongnam-si 13120, Republic of Korea
| | - Heongkyu Ju
- Department of Physics, Gachon University, Seongnam-si 13120, Republic of Korea; (R.R.); (K.S.)
- Gachon Bionano Research Institute, Gachon University, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
2
|
Kosame S, Josline MJ, Lee JH, Ju H. Anomalous spectral shift of localized surface plasmon resonance. NANOSCALE ADVANCES 2024; 6:2636-2643. [PMID: 38752138 PMCID: PMC11093275 DOI: 10.1039/d3na01131c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 04/03/2024] [Indexed: 05/18/2024]
Abstract
We report the first observation of spectral blue shift of plasmon resonance of synthesized silver nanoparticles (AgNPs) due to a negative optical nonlinearity of a local ambient medium, i.e., indigo carmine (IC) solution at around 420 nm wavelength. The blue shift occurred at a larger concentration of AgNPs or at a larger concentration of IC solution, being in obvious contrast to spectral red shift which was widely witnessed in plasmon spectral shift in a linear regime. Plasmon-enhanced local fields could excite the third-order optical nonlinearity for blue shift even under continuous (non-pulsed) light illumination. We also found that the plasmon-excited nonlinearity could allow for differential nonlinear response of the IC solution to be even greater than its differential linear response, though appearing to be somewhat inconsistent with what was generally known in light-matter interaction. The demonstrated properties of such anomalous shift of plasmon spectral peaks and its accompanying properties indicated that plasmon technologies could be exploited not only in linear but also in nonlinear aspects for critical optimization in plasmon-energy harvesting systems such as in surface enhanced spectroscopy/microscopy, biomedical imaging/sensing, laser frequency conversion, ultrashort pulse generation, and all-optical switching.
Collapse
Affiliation(s)
- Saikiran Kosame
- Department of Physics, Gachon University Seongnam-si 13120 Republic of Korea
| | - Mukkath Joseph Josline
- Department of Materials Science and Engineering, Ajou University Suwon Korea
- Department of Energy Systems Research, Ajou University Suwon Korea
| | - Jae-Hyun Lee
- Department of Materials Science and Engineering, Ajou University Suwon Korea
- Department of Energy Systems Research, Ajou University Suwon Korea
| | - Heongkyu Ju
- Department of Physics, Gachon University Seongnam-si 13120 Republic of Korea
| |
Collapse
|
3
|
Phuong NTT, Phung VD, Le TBN, Chi T, Hien BTT, Tho LH, Mai NXD, Phan TB, Tran NHT, Ju H. Ultrasensitive Monitoring of Cyanide Concentrations in Water Using a Au core-Ag shell Hybrid-Coating-Based Fiber Optical Sensor. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:15799-15807. [PMID: 37883714 DOI: 10.1021/acs.langmuir.3c02499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
Cyanides, which are extremely toxic chemicals that are rapidly absorbed into the human body and interact with cytochrome oxidase, strongly inhibit cellular respiration to body death with convulsions. Cyanide ions that exist in many forms in nature such as those found in apricot kernels, cassava roots, and bamboo shoots as cyanogenic glycosides are inevitably used in various industries, including gold and silver mining as well as in dyes and plastic industries. In this study, for the sake of developing ultrahigh-sensitive sensors for cyanide monitoring in a simple manner, we chemically synthesize Aucore-Agshell hybrid nanomaterials of different core/shell thicknesses for colorimetric sensors and fiber optical sensors. Their sensing principle relies on the formation of the Ag/Au cyanocomplex upon cyanide injection. The generated metal cyanocomplex induced changes in refractive indices, causing changes in properties of localized surface plasmon resonance (LSPR), i.e., optical absorbance change for the colorimetric sensors. For fiber optical sensors, the hybrid metal nanoparticles were immobilized on the fiber core surface and the metal cyanocomplex formation induced changes in the fiber cladding refractive index, enabling quantitative cyanide detection with ultrahigh sensitivity. The LSPR-based colorimetric sensor provided the lowest detectable cyanide concentration of 5 × 10-6 M, whereas the value for the fiber-based sensor was 8 × 10-11 M.
Collapse
Affiliation(s)
- Nguyen Tran Truc Phuong
- Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City 70000, Vietnam
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City 700000, Vietnam
| | - Viet-Duc Phung
- Institute of Fundamental and Applied Sciences, Duy Tan University, Ho Chi Minh City 700000, Vietnam
- Faculty of Environmental and Chemical Engineering, Duy Tan University, Da Nang City550000, Vietnam
| | - Thu Bao Nguyen Le
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
- Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 70000, Vietnam
| | - Tran Chi
- Institute of Materials Science, Vietnam Academy of Science and Technology, Hanoi 0084, Vietnam
| | - Bui Thi Thu Hien
- Institute of Materials Science, Vietnam Academy of Science and Technology, Hanoi 0084, Vietnam
| | - Le Hong Tho
- Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City 70000, Vietnam
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), Ho Chi Minh City 70000, Vietnam
| | - Ngoc Xuan Dat Mai
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), Ho Chi Minh City 70000, Vietnam
| | - Thang Bach Phan
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), Ho Chi Minh City 70000, Vietnam
| | - Nhu Hoa Thi Tran
- Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City 70000, Vietnam
- Vietnam National University, Ho Chi Minh City 70000, Vietnam
| | - Heongkyu Ju
- Department of Physics, Gachon University, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
4
|
Rajamanikandan R, Ilanchelian M, Ju H. Smartphone-enabled colorimetric visual quantification of highly hazardous trivalent chromium ions in environmental waters and catalytic reduction of p-nitroaniline by thiol-functionalized gold nanoparticles. CHEMOSPHERE 2023; 340:139838. [PMID: 37598944 DOI: 10.1016/j.chemosphere.2023.139838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 07/27/2023] [Accepted: 08/14/2023] [Indexed: 08/22/2023]
Abstract
High-efficiency sensing systems for extremely hazardous chromium (Cr(III)) ions are important due to their detrimental effects on human health and the environment. We employed a spectrophotometric method combined with a smartphone (red, green, and blue (RGB) color ratio)-based detection platform to realize the quick, visually quantifiable in situ detection of Cr(III) ions using surface plasmon resonance (SPR)-aided colorimetry. For optical sensing nanoprobes, we synthesized the 2-Mercapto-5-methyl-1,3,4-thiadiazole (MMT)-modified gold nanoparticles (MMT-AuNPs) using a wet chemical method. By way of a coordination reaction, the Cr(III) ions induce the as-prepared MMT-AuNPs to aggregate and subsequently change the SPR wavelength band. The freshly synthesized MMT-AuNPs exhibited a wine-red color. While Cr(III) ions interact with the MMT-AuNPs, the color of the latter evolved from wine red to purple, thus facilitating visual monitoring. The SPR-relevant color change allowed the quantitative sensing of Cr(III) ions in the range of 40-128 nM, with the limit of detection of 6.93 nM when employing the spectrophotometric method and 12.4 nM when using the smartphone RGB color ratio. Furthermore, we developed the spectrophotometric technique that used the smartphone RGB color ratio for on-site analysis of Cr(III) ions in environmental water samples, indicating the possibility of its chemo-sensing applications for portable quantitative detection devices. Additionally, the catalytic performance of the MMT-AuNPs was demonstrated by the reduction of p-nitroaniline in the presence of sodium borohydride. It was interestingly unveiled that the MMT-AuNPs showed outstanding catalytic performance with a catalytic rate constant of 6.31 × 10-3 s-1.
Collapse
Affiliation(s)
| | | | - Heongkyu Ju
- Department of Physics, Gachon University, Seongnam-si, 13120, Republic of Korea.
| |
Collapse
|
5
|
Rajamanikandan R, Shanmugaraj K, Ilanchelian M, Ju H. Cysteamine-decorated gold nanoparticles for plasmon-based colorimetric on-site sensors for detecting cyanide ions using the smart-phone color ratio and for catalytic reduction of 4-nitrophenol. CHEMOSPHERE 2023; 316:137836. [PMID: 36642146 DOI: 10.1016/j.chemosphere.2023.137836] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 12/12/2022] [Accepted: 01/10/2023] [Indexed: 06/17/2023]
Abstract
In this paper, we have reported the cyanide ions (CN-) sensing in environmental water samples using cysteamine-capped gold nanoparticles (Cyst-AuNPs) by spectrophotometric, colorimetric, and smartphone-based RGB color detection. The surface plasmon resonance shift at around 525 nm for the Cyst-AuNPs could be used to detect quantitatively the amounts of CN- with concomitant alteration of their color from wine red to purple visualized by the naked eye. For the first time, the Cyst-AuNPs-based visual sensing of CN- was performed using smartphone-based detection with its detection limit of 159 × 10-9 M, ten times lower than that of the highest tolerance level (2 × 10-6 M) permitted by the world health organization. The Cyst-AuNPs displayed excellent specificity for detecting the concentration of 30 × 10-6 M even amid the presence of other interfering inorganic anions with their concentrations about five times higher than it. Environmental real water samples were used to arrange the three different CN- concentrations for plasmon-based colorimetric detection and smartphone-based method. Additionally, the catalytic performance of Cyst-AuNPs was demonstrated for the fast catalytic conversion of hazardous 4-nitrophenol (selected environmental contaminant) to the analogous amino aromatic compounds. A chemical kinetic study showed the conversion rate to be estimated as 1.65 × 10-2 s-1. Cyst-AuNPs can find an application in colorimetric sensing of CN- while being able to be utilized as a catalytic nanomaterial for ecological remedies associated with health care.
Collapse
Affiliation(s)
| | - Krishnamoorthy Shanmugaraj
- Advanced Ceramics and Nanotechnology Laboratory, Department of Materials Engineering, Universidad de Concepción, Concepción, Chile; Faculty of Engineering and Science, Universidad Adolfo Ibáñez, Diagonal Las Torres, 2640, Peñalolén, Santiago, Chile
| | | | - Heongkyu Ju
- Department of Physics, Gachon University, Seongnam-si, 13120, Republic of Korea.
| |
Collapse
|
6
|
Rajamanikandan R, Sasikumar K, Kosame S, Ju H. Optical Sensing of Toxic Cyanide Anions Using Noble Metal Nanomaterials. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:nano13020290. [PMID: 36678042 PMCID: PMC9863761 DOI: 10.3390/nano13020290] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 06/12/2023]
Abstract
Water toxicity, one of the major concerns for ecosystems and the health of humanity, is usually attributed to inorganic anions-induced contamination. Particularly, cyanide ions are considered one of the most harmful elements required to be monitored in water. The need for cyanide sensing and monitoring has tempted the development of sensing technologies without highly sophisticated instruments or highly skilled operations for the objective of in-situ monitoring. Recent decades have witnessed the growth of noble metal nanomaterials-based sensors for detecting cyanide ions quantitatively as nanoscience and nanotechnologies advance to allow nanoscale-inherent physicochemical properties to be exploited for sensing performance. Particularly, noble metal nanostructure e-based optical sensors have permitted cyanide ions of nanomolar levels, or even lower, to be detectable. This capability lends itself to analytical application in the quantitative detection of harmful elements in environmental water samples. This review covers the noble metal nanomaterials-based sensors for cyanide ions detection developed in a variety of approaches, such as those based on colorimetry, fluorescence, Rayleigh scattering (RS), and surface-enhanced Raman scattering (SERS). Additionally, major challenges associated with these nano-platforms are also addressed, while future perspectives are given with directions towards resolving these issues.
Collapse
|
7
|
Zhang J, Chen M, Peng Y, Li S, Han D, Ren S, Qin K, Li S, Han T, Wang Y, Gao Z. Wearable biosensors for human fatigue diagnosis: A review. Bioeng Transl Med 2023; 8:e10318. [PMID: 36684114 PMCID: PMC9842037 DOI: 10.1002/btm2.10318] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/11/2022] [Accepted: 03/13/2022] [Indexed: 02/01/2023] Open
Abstract
Fatigue causes deleterious effects to physical and mental health of human being and may cause loss of lives. Therefore, the adverse effects of fatigue on individuals and the society are massive. With the ever-increasing frequency of overtraining among modern military and sports personnel, timely, portable and accurate fatigue diagnosis is essential to avoid fatigue-induced accidents. However, traditional detection methods require complex sample preparation and blood sampling processes, which cannot meet the timeliness and portability of fatigue diagnosis. With the development of flexible materials and biosensing technology, wearable biosensors have attracted increased attention to the researchers. Wearable biosensors collect biomarkers from noninvasive biofluids, such as sweat, saliva, and tears, followed by biosensing with the help of biosensing modules continuously and quantitatively. The detection signal can then be transmitted through wireless communication modules that constitute a method for real-time understanding of abnormality. Recent developments of wearable biosensors are focused on miniaturized wearable electrochemistry and optical biosensors for metabolites detection, of which, few have exhibited satisfactory results in medical diagnosis. However, detection performance limits the wide-range applicability of wearable fatigue diagnosis. In this article, the application of wearable biosensors in fatigue diagnosis has been discussed. In fact, exploration of the composition of different biofluids and their potential toward fatigue diagnosis have been discussed here for the very first time. Moreover, discussions regarding the current bottlenecks in wearable fatigue biosensors and the latest advancements in biochemical reaction and data communication modules have been incorporated herein. Finally, the main challenges and opportunities were discussed for wearable fatigue diagnosis in the future.
Collapse
Affiliation(s)
- Jingyang Zhang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Mengmeng Chen
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Yuan Peng
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Shuang Li
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Dianpeng Han
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Shuyue Ren
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Kang Qin
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Sen Li
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Tie Han
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Yu Wang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety Institute of Environmental and Operational Medicine Tianjin P.R. China
| |
Collapse
|
8
|
Konoplev G, Agafonova D, Bakhchova L, Mukhin N, Kurachkina M, Schmidt MP, Verlov N, Sidorov A, Oseev A, Stepanova O, Kozyrev A, Dmitriev A, Hirsch S. Label-Free Physical Techniques and Methodologies for Proteins Detection in Microfluidic Biosensor Structures. Biomedicines 2022; 10:207. [PMID: 35203416 PMCID: PMC8868674 DOI: 10.3390/biomedicines10020207] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 01/01/2022] [Accepted: 01/11/2022] [Indexed: 12/25/2022] Open
Abstract
Proteins in biological fluids (blood, urine, cerebrospinal fluid) are important biomarkers of various pathological conditions. Protein biomarkers detection and quantification have been proven to be an indispensable diagnostic tool in clinical practice. There is a growing tendency towards using portable diagnostic biosensor devices for point-of-care (POC) analysis based on microfluidic technology as an alternative to conventional laboratory protein assays. In contrast to universally accepted analytical methods involving protein labeling, label-free approaches often allow the development of biosensors with minimal requirements for sample preparation by omitting expensive labelling reagents. The aim of the present work is to review the variety of physical label-free techniques of protein detection and characterization which are suitable for application in micro-fluidic structures and analyze the technological and material aspects of label-free biosensors that implement these methods. The most widely used optical and impedance spectroscopy techniques: absorption, fluorescence, surface plasmon resonance, Raman scattering, and interferometry, as well as new trends in photonics are reviewed. The challenges of materials selection, surfaces tailoring in microfluidic structures, and enhancement of the sensitivity and miniaturization of biosensor systems are discussed. The review provides an overview for current advances and future trends in microfluidics integrated technologies for label-free protein biomarkers detection and discusses existing challenges and a way towards novel solutions.
Collapse
Affiliation(s)
- Georgii Konoplev
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
| | - Darina Agafonova
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
| | - Liubov Bakhchova
- Institute for Automation Technology, Otto-von-Guericke-University Magdeburg, 39106 Magdeburg, Germany;
| | - Nikolay Mukhin
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
- Department of Engineering, University of Applied Sciences Brandenburg, 14770 Brandenburg an der Havel, Germany; (M.K.); (S.H.)
| | - Marharyta Kurachkina
- Department of Engineering, University of Applied Sciences Brandenburg, 14770 Brandenburg an der Havel, Germany; (M.K.); (S.H.)
| | - Marc-Peter Schmidt
- Faculty of Electrical Engineering, University of Applied Sciences Dresden, 01069 Dresden, Germany;
| | - Nikolay Verlov
- Molecular and Radiation Biophysics Division, Petersburg Nuclear Physics Institute Named by B.P. Konstantinov, National Research Centre Kurchatov Institute, 188300 Gatchina, Russia;
| | - Alexander Sidorov
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
- Fuculty of Photonics, ITMO University, 197101 Saint Petersburg, Russia
| | - Aleksandr Oseev
- FEMTO-ST Institute, CNRS UMR-6174, University Bourgogne Franche-Comté, 25000 Besançon, France;
| | - Oksana Stepanova
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
| | - Andrey Kozyrev
- Faculty of Electronics, Saint Petersburg Electrotechnical University “LETI”, 197376 Saint Petersburg, Russia; (D.A.); (A.S.); (O.S.); (A.K.)
| | - Alexander Dmitriev
- Department of Ecological Physiology, Federal State Budgetary Scientific Institution “Institute of Experimental Medicine” (FSBSI “IEM”), 197376 Saint Petersburg, Russia;
| | - Soeren Hirsch
- Department of Engineering, University of Applied Sciences Brandenburg, 14770 Brandenburg an der Havel, Germany; (M.K.); (S.H.)
| |
Collapse
|
9
|
Kastner S, Pritzke P, Csáki A, Fritzsche W. The effect of layer thickness and immobilization chemistry on the detection of CRP in LSPR assays. Sci Rep 2022; 12:836. [PMID: 35039589 PMCID: PMC8763948 DOI: 10.1038/s41598-022-04824-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 12/17/2021] [Indexed: 11/08/2022] Open
Abstract
The immobilization of a capture molecule represents a crucial step for effective usage of gold nanoparticles in localized surface plasmon resonance (LSPR)-based bioanalytics. Depending on the immobilization method used, the resulting capture layer is of varying thickness. Thus, the target binding event takes place at different distances to the gold surface. Using the example of a C-reactive protein immunoassay, different immobilization methods were tested and investigated with regard to their resulting target signal strength. The dependency of the target signal on the distance to the gold surface was investigated utilizing polyelectrolyte bilayers of different thickness. It could be experimentally demonstrated how much the LSPR-shift triggered by a binding event on the gold nanoparticles decreases with increasing distance to the gold surface. Thus, the sensitivity of an LSPR assay is influenced by the choice of immobilization chemistry.
Collapse
Affiliation(s)
- Stephan Kastner
- Department Nanobiophotonics, Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Strasse 9, 07745, Jena, Germany
| | - Pia Pritzke
- Department Nanobiophotonics, Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Strasse 9, 07745, Jena, Germany
| | - Andrea Csáki
- Department Nanobiophotonics, Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Strasse 9, 07745, Jena, Germany
| | - Wolfgang Fritzsche
- Department Nanobiophotonics, Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Strasse 9, 07745, Jena, Germany.
| |
Collapse
|
10
|
Real Time SPR Assessment of the Structural Changes of Adaptive Dynamic Constitutional Frameworks as a New Route for Sensing. MATERIALS 2022; 15:ma15020483. [PMID: 35057201 PMCID: PMC8779961 DOI: 10.3390/ma15020483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 12/22/2021] [Accepted: 01/04/2022] [Indexed: 11/30/2022]
Abstract
Cross linked gold-dynamic constitutional frameworks (DCFs) are functional materials of potential relevance for biosensing applications, given their adaptivity and high responsivity against various external stimuli (such as pH, temperature) or specific interactions with biomolecules (enzymes or DNA) via internal constitutional dynamics. However, characterization and assessment of their dynamic conformational changes in response to external stimuli has never been reported. This study proves the capability of Surface Plasmon Resonance (SPR) assays to analyse the adaptive structural modulation of a functional matrix encompassing 3D gold-dynamic constitutional frameworks (Au-DCFs) when exposed to pH variations, as external stimuli. We analyse Au-DCFs formed from Au nanoparticles, (AuNP) connected through constitutionally dynamic polymers, dynamers, with multiple functionalities. For increased generality of this proof-of-concept assay, Au-DCFs, involving DCFs designed from 1,3,5-benzene-tricarbaldehyde (BTA) connecting centres and polyethylene glycol (PEG) connectors, are covalently attached to standard SPR sensing chips (Au nanolayers, carboxyl terminated or with carboxymethyl dextran, CMD top-layer) and analysed using state-of-the art SPR instrumentation. The SPR effects of the distance from the Au-DCFs matrix to the Au nanolayer of the sensing chip, as well as of Au-DCFs thickness were investigated. This study reveals the SPR response, augmented by the AuNP, to the conformational change, i.e., shrinkage, of the dynamer and AuNP matrix when decreasing the pH, and provides an unexplored insight into the sensing applicability of SPR real-time analysis of adaptive functional materials.
Collapse
|
11
|
Roadmap on Universal Photonic Biosensors for Real-Time Detection of Emerging Pathogens. PHOTONICS 2021. [DOI: 10.3390/photonics8080342] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The COVID-19 pandemic has made it abundantly clear that the state-of-the-art biosensors may not be adequate for providing a tool for rapid mass testing and population screening in response to newly emerging pathogens. The main limitations of the conventional techniques are their dependency on virus-specific receptors and reagents that need to be custom-developed for each recently-emerged pathogen, the time required for this development as well as for sample preparation and detection, the need for biological amplification, which can increase false positive outcomes, and the cost and size of the necessary equipment. Thus, new platform technologies that can be readily modified as soon as new pathogens are detected, sequenced, and characterized are needed to enable rapid deployment and mass distribution of biosensors. This need can be addressed by the development of adaptive, multiplexed, and affordable sensing technologies that can avoid the conventional biological amplification step, make use of the optical and/or electrical signal amplification, and shorten both the preliminary development and the point-of-care testing time frames. We provide a comparative review of the existing and emergent photonic biosensing techniques by matching them to the above criteria and capabilities of preventing the spread of the next global pandemic.
Collapse
|
12
|
Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination. BIOSENSORS-BASEL 2021; 11:bios11080268. [PMID: 34436070 PMCID: PMC8394791 DOI: 10.3390/bios11080268] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 07/26/2021] [Accepted: 08/05/2021] [Indexed: 02/07/2023]
Abstract
The development of methods and miniaturized systems for fast and reliable quantitative determinations at the Point-of-Care is a top challenge and priority in diagnostics. In this work, a compact bench-top system, based on White Light Reflectance Spectroscopy, is introduced and evaluated in an application with high clinical interest, namely the determination of C-Reactive protein (CRP) in human blood samples. The system encompassed all the necessary electronic and optical components for the performance of the assay, while the dedicated software provided the sequence and duration of assay steps, the reagents flow rate, the real-time monitoring of sensor response, and data processing to deliver in short time and accurately the CPR concentration in the sample. The CRP assay included two steps, the first comprising the binding of sample CRP onto the chip immobilized capture antibody and the second the reaction of the surface immunosorbed CRP molecules with the detection antibody. The assay duration was 12 min and the dynamic range was from 0.05 to 200 μg/mL, covering both normal values and acute inflammation incidents. There was an excellent agreement between CRP values determined in human plasma samples using the developed device with those received for the same samples by a standard diagnostic laboratory method.
Collapse
|