1
|
Brasiunas B, Popov A, Lisyte V, Kausaite-Minkstimiene A, Ramanaviciene A. ZnO nanostructures: A promising frontier in immunosensor development. Biosens Bioelectron 2024; 246:115848. [PMID: 38042053 DOI: 10.1016/j.bios.2023.115848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 11/01/2023] [Accepted: 11/15/2023] [Indexed: 12/04/2023]
Abstract
This review addresses the design of immunosensors, which employ ZnO nanostructures. Various methods of modifying ZnO nanostructures with antibodies or antigens are discussed, including covalent and non-covalent approaches and cross-linking techniques. Immunosensors based on different properties of ZnO nanomaterials are described and compared. This article provides a comprehensive review of electrochemical immunosensors based on ZnO nanostructures and various detection techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), photoelectrochemical (PEC) detection, electrochemical impedance spectroscopy (EIS), and other electrochemical methods. In addition, this review article examines the application of optical detection techniques, including photoluminescence (PL) and electrochemiluminescence (ECL), in the development of immunosensors based on ZnO nanostructures.
Collapse
Affiliation(s)
- Benediktas Brasiunas
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Anton Popov
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Viktorija Lisyte
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Asta Kausaite-Minkstimiene
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania
| | - Almira Ramanaviciene
- NanoTechnas - Nanotechnology and Materials Science Center, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT 03225, Vilnius, Lithuania.
| |
Collapse
|
2
|
Vetrivel C, Sivarasan G, Durairaj K, Ragavendran C, Kamaraj C, Karthika S, Lo HM. MoS 2-ZnO Nanocomposite Mediated Immunosensor for Non-Invasive Electrochemical Detection of IL8 Oral Tumor Biomarker. Diagnostics (Basel) 2023; 13:diagnostics13081464. [PMID: 37189565 DOI: 10.3390/diagnostics13081464] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 04/07/2023] [Accepted: 04/13/2023] [Indexed: 05/17/2023] Open
Abstract
In order to support biomolecule attachment, an effective electrochemical transducer matrix for biosensing devices needs to have many specialized properties, including quick electron transfer, stability, high surface area, biocompatibility, and the presence of particular functional groups. Enzyme-linked immunosorbent assays, gel electrophoresis, mass spectrometry, fluorescence spectroscopy, and surface-enhanced Raman spectroscopy are common techniques used to assess biomarkers. Even though these techniques provide precise and trustworthy results, they cannot replace clinical applications because of factors such as detection time, sample amount, sensitivity, equipment expense, and the need for highly skilled individuals. For the very sensitive and targeted electrochemical detection of the salivary oral cancer biomarker IL8, we have created a flower-structured molybdenum disulfide-decorated zinc oxide composite on GCE (interleu-kin-8). This immunosensor shows very fast detection; the limit of detection (LOD) for interleukin-8 (IL8) detection in a 0.1 M phosphate buffer solution (PBS) was discovered to be 11.6 fM, while the MoS2/ZnO nanocomposite modified glassy carbon electrode (GCE) demonstrated a high catalytic current linearly from 500 pg to 4500 pg mL-1 interleukin-8 (IL8). Therefore, the proposed biosensor exhibits excellent stability, high accuracy sensitivity, repeatability, and reproducibility and shows the acceptable fabrication of the electrochemical biosensors to detect the ACh in real sample analysis.
Collapse
Affiliation(s)
- Cittrarasu Vetrivel
- Carbon Capture Lab, Department of Chemical Engineering, SSN College of Engineering Kalavakkam, Chennai 603110, Tamil Nadu, India
- Department of Anatomy, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, Tamil Nadu, India
| | - Ganesan Sivarasan
- Department of Environmental Engineering and Management, Chaoyang University of Technology, Taichung 41349, Taiwan
| | - Kaliannan Durairaj
- Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, Iksan 54538, Republic of Korea
| | - Chinnasamy Ragavendran
- Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, Tamil Nadu, India
| | - Chinnaperumal Kamaraj
- Interdisciplinary Institute of Indian System of Medicine (IIISM), Directorate of Research and Virtual Education, SRM Institute of Science and Technology (SRMIST), Kattankulathur 603203, Tamil Nadu, India
| | - Sankar Karthika
- Department of Biotechnology, Mahendra Arts and Science College (Autonomous), Namakkal 637501, Tamil Nadu, India
| | - Huang-Mu Lo
- Department of Environmental Engineering and Management, Chaoyang University of Technology, Taichung 41349, Taiwan
| |
Collapse
|
3
|
Nunez FA, Castro ACH, de Oliveira VL, Lima AC, Oliveira JR, de Medeiros GX, Sasahara GL, Santos KS, Lanfredi AJC, Alves WA. Electrochemical Immunosensors Based on Zinc Oxide Nanorods for Detection of Antibodies Against SARS-CoV-2 Spike Protein in Convalescent and Vaccinated Individuals. ACS Biomater Sci Eng 2023; 9:458-473. [PMID: 36048716 PMCID: PMC9469957 DOI: 10.1021/acsbiomaterials.2c00509] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 08/24/2022] [Indexed: 01/11/2023]
Abstract
Even after over 2 years of the COVID-19 pandemic, research on rapid, inexpensive, and accurate tests remains essential for controlling and avoiding the global spread of SARS-CoV-2 across the planet during a potential reappearance in future global waves or regional outbreaks. Assessment of serological responses for COVID-19 can be beneficial for population-level surveillance purposes, supporting the development of novel vaccines and evaluating the efficacy of different immunization programs. This can be especially relevant for broadly used inactivated whole virus vaccines, such as CoronaVac, which produced lower titers of neutralizing antibodies. and showed lower efficacy for specific groups such as the elderly and immunocompromised. We developed an impedimetric biosensor based on the immobilization of SARS-CoV-2 recombinant trimeric spike protein (S protein) on zinc oxide nanorod (ZnONR)-modified fluorine-doped tin oxide substrates for COVID-19 serology testing. Due to electrostatic interactions, the negatively charged S protein was immobilized via physical adsorption. The electrochemical response of the immunosensor was measured at each modification step and characterized by scanning electron microscopy and electrochemical techniques. We successfully evaluated the applicability of the modified ZnONR electrodes using serum samples from COVID-19 convalescent individuals, CoronaVac-vaccinated with or without positive results for SARS-CoV-2 infection, and pre-pandemic samples from healthy volunteers as controls. ELISA for IgG anti-SARS-CoV-2 spike protein was performed for comparison, and ELISA for IgG anti-RBDs of seasonal coronavirus (HCoVs) was used to test the specificity of immunosensor detection. No cross-reactivity with HCoVs was detected using the ZnONR immunosensor, and more interestingly, the sensor presented higher sensitivity when compared to negative ELISA results. The results demonstrate that the ZnONRs/spike-modified electrode displayed sensitive results for convalescents and vaccinated samples and shows excellent potential as a tool for the population's assessment and monitoring of seroconversion and seroprevalence.
Collapse
Affiliation(s)
- Freddy A. Nunez
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| | - Ana C. H. Castro
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| | - Vivian L. de Oliveira
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
| | - Ariane C. Lima
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Jamille R. Oliveira
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Giuliana X. de Medeiros
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Greyce L. Sasahara
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
| | - Keity S. Santos
- Laboratório de Imunologia, LIM19, Instituto do
Coração (InCor), Hospital das Clínicas da Faculdade de
Medicina da Universidade de São Paulo (HCFMUSP), Av. Dr. Arnaldo,
44, São Paulo, São Paulo05403-900, Brazil
- Departamento de Clínica Médica, Disciplina
de Alergia e Imunologia Clínica, Faculdade de Medicina da Universidade
de São Paulo, Av. Dr. Arnaldo, 455, São Paulo, São
Paulo01246-903, Brazil
| | - Alexandre J. C. Lanfredi
- Centro de Engenharia, Modelagem e Ciências
Sociais Aplicadas, Universidade Federal do ABC, Av. dos
Estados, 5001, Santo André, São Paulo09210-580,
Brazil
| | - Wendel A. Alves
- Centro de Ciências Naturais e Humanas,
Universidade Federal do ABC, Av. dos Estados, 5001, Santo
André, São Paulo09210-580, Brazil
| |
Collapse
|
4
|
Zhang X, Zhang Z, Diao W, Zhou C, Song Y, Wang R, Luo X, Liu G. Early-diagnosis of major depressive disorder: From biomarkers to point-of-care testing. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
5
|
Haghayegh F, Salahandish R, Hassani M, Sanati-Nezhad A. Highly Stable Buffer-Based Zinc Oxide/Reduced Graphene Oxide Nanosurface Chemistry for Rapid Immunosensing of SARS-CoV-2 Antigens. ACS APPLIED MATERIALS & INTERFACES 2022; 14:10844-10855. [PMID: 35172574 DOI: 10.1021/acsami.1c24475] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The widespread and long-lasting effect of the COVID-19 pandemic has called attention to the significance of technological advances in the rapid diagnosis of SARS-CoV-2 virus. This study reports the use of a highly stable buffer-based zinc oxide/reduced graphene oxide (bbZnO/rGO) nanocomposite coated on carbon screen-printed electrodes for electrochemical immuno-biosensing of SARS-CoV-2 nuelocapsid (N-) protein antigens in spiked and clinical samples. The incorporation of a salt-based (ionic) matrix for uniform dispersion of the nanomixture eliminates multistep nanomaterial synthesis on the surface of the electrode and enables a stable single-step sensor nanocoating. The immuno-biosensor provides a limit of detection of 21 fg/mL over a linear range of 1-10 000 pg/mL and exhibits a sensitivity of 32.07 ohms·mL/pg·mm2 for detection of N-protein in spiked samples. The N-protein biosensor is successful in discriminating positive and negative clinical samples within 15 min, demonstrating its proof of concept used as a COVID-19 rapid antigen test.
Collapse
Affiliation(s)
- Fatemeh Haghayegh
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
| | - Razieh Salahandish
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
- Center for BioEngineering Research and Education, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Mohsen Hassani
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
| | - Amir Sanati-Nezhad
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
- Center for BioEngineering Research and Education, University of Calgary, Calgary, Alberta T2N 1N4, Canada
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| |
Collapse
|
6
|
Patella B, Moukri N, Regalbuto G, Cipollina C, Pace E, Di Vincenzo S, Aiello G, O’Riordan A, Inguanta R. Electrochemical Synthesis of Zinc Oxide Nanostructures on Flexible Substrate and Application as an Electrochemical Immunoglobulin-G Immunosensor. MATERIALS (BASEL, SWITZERLAND) 2022; 15:713. [PMID: 35160668 PMCID: PMC8837124 DOI: 10.3390/ma15030713] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 11/17/2022]
Abstract
Immunoglobulin G (IgG), a type of antibody, represents approximately 75% of serum antibodies in humans, and is the most common type of antibody found in blood circulation. Consequently, the development of simple, fast and reliable systems for IgG detection, which can be achieved using electrochemical sandwich-type immunosensors, is of considerable interest. In this study we have developed an immunosensor for human (H)-IgG using an inexpensive and very simple fabrication method based on ZnO nanorods (NRs) obtained through the electrodeposition of ZnO. The ZnO NRs were treated by electrodepositing a layer of reduced graphene oxide (rGO) to ensure an easy immobilization of the antibodies. On Indium Tin Oxide supported on Polyethylene Terephthalate/ZnO NRs/rGO substrate, the sandwich configuration of the immunosensor was built through different incubation steps, which were all optimized. The immunosensor is electrochemically active thanks to the presence of gold nanoparticles tagging the secondary antibody. The immunosensor was used to measure the current density of the hydrogen development reaction which is indirectly linked to the concentration of H-IgG. In this way the calibration curve was constructed obtaining a logarithmic linear range of 10-1000 ng/mL with a detection limit of few ng/mL and good sensitivity.
Collapse
Affiliation(s)
- Bernardo Patella
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Nadia Moukri
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Gaia Regalbuto
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Chiara Cipollina
- Fondazione Ri.MED, 90133 Palermo, Italy;
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Elisabetta Pace
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Serena Di Vincenzo
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Giuseppe Aiello
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Alan O’Riordan
- Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland;
| | - Rosalinda Inguanta
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| |
Collapse
|