1
|
Abraham A, Virdi S, Herrero N, Bryant I, Nwakama C, Jacob M, Khaparde G, Jordan D, McCuddin M, McKinley S, Taylor A, Peeples C, Ekpenyong A. Microfluidic Microcirculation Mimetic for Exploring Biophysical Mechanisms of Chemotherapy-Induced Metastasis. MICROMACHINES 2023; 14:1653. [PMID: 37763816 PMCID: PMC10536821 DOI: 10.3390/mi14091653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/18/2023] [Accepted: 08/19/2023] [Indexed: 09/29/2023]
Abstract
There is rapidly emerging evidence from pre-clinical studies, patient samples and patient subpopulations that certain chemotherapeutics inadvertently produce prometastatic effects. Prior to this, we showed that doxorubicin and daunorubicin stiffen cells before causing cell death, predisposing the cells to clogging and extravasation, the latter being a step in metastasis. Here, we investigate which other anti-cancer drugs might have similar prometastatic effects by altering the biophysical properties of cells. We treated myelogenous (K562) leukemic cancer cells with the drugs nocodazole and hydroxyurea and then measured their mechanical properties using a microfluidic microcirculation mimetic (MMM) device, which mimics aspects of blood circulation and enables the measurement of cell mechanical properties via transit times through the device. We also quantified the morphological properties of cells to explore biophysical mechanisms underlying the MMM results. Results from MMM measurements show that nocodazole- and hydroxyurea-treated K562 cells exhibit significantly altered transit times. Nocodazole caused a significant (p < 0.01) increase in transit times, implying a stiffening of cells. This work shows the feasibility of using an MMM to explore possible biophysical mechanisms that might contribute to chemotherapy-induced metastasis. Our work also suggests cell mechanics as a therapeutic target for much needed antimetastatic strategies in general.
Collapse
Affiliation(s)
- Ashley Abraham
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Sukhman Virdi
- Physics Department, Creighton University, Omaha, NE 68178, USA; (S.V.); (I.B.); (C.P.)
| | - Nick Herrero
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Israel Bryant
- Physics Department, Creighton University, Omaha, NE 68178, USA; (S.V.); (I.B.); (C.P.)
| | - Chisom Nwakama
- Chemistry Department, Creighton University, Omaha, NE 68178, USA;
| | - Megha Jacob
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Gargee Khaparde
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Destiny Jordan
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Mackenzie McCuddin
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Spencer McKinley
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Adam Taylor
- Biology Department, Creighton University, Omaha, NE 68178, USA; (A.A.); (N.H.); (M.J.); (G.K.); (D.J.); (M.M.); (S.M.); (A.T.)
| | - Conner Peeples
- Physics Department, Creighton University, Omaha, NE 68178, USA; (S.V.); (I.B.); (C.P.)
| | - Andrew Ekpenyong
- Physics Department, Creighton University, Omaha, NE 68178, USA; (S.V.); (I.B.); (C.P.)
| |
Collapse
|
2
|
Zhang R, Duan X, Zhang S, Guo W, Sun C, Han Z. Tunable microfluidic chip for single-cell deformation study. NANOTECHNOLOGY AND PRECISION ENGINEERING 2023. [DOI: 10.1063/10.0017649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
Microfluidic phenotyping methods have been of vital importance for cellular characterization, especially for evaluating single cells. In order to study the deformability of a single cell, we devised and tested a tunable microfluidic chip-based method. A pneumatic polymer polydimethylsiloxane (PDMS) membrane was designed and fabricated abutting a single-cell trapping structure, so the cell could be squeezed controllably in a lateral direction. Cell contour changes under increasing pressure were recorded, enabling the deformation degree of different types of single cell to be analyzed and compared using computer vision. This provides a new perspective for studying mechanical properties of cells at the single cell level.
Collapse
Affiliation(s)
- Ruiyun Zhang
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Shuaihua Zhang
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Wenlan Guo
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Chen Sun
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Ziyu Han
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| |
Collapse
|
3
|
Wubshet NH, Liu AP. Methods to mechanically perturb and characterize GUV-based minimal cell models. Comput Struct Biotechnol J 2022; 21:550-562. [PMID: 36659916 PMCID: PMC9816913 DOI: 10.1016/j.csbj.2022.12.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/15/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022] Open
Abstract
Cells shield organelles and the cytosol via an active boundary predominantly made of phospholipids and membrane proteins, yet allowing communication between the intracellular and extracellular environment. Micron-sized liposome compartments commonly known as giant unilamellar vesicles (GUVs) are used to model the cell membrane and encapsulate biological materials and processes in a cell-like confinement. In the field of bottom-up synthetic biology, many have utilized GUVs as substrates to study various biological processes such as protein-lipid interactions, cytoskeletal assembly, and dynamics of protein synthesis. Like cells, it is ideal that GUVs are also mechanically durable and able to stay intact when the inner and outer environment changes. As a result, studies have demonstrated approaches to tune the mechanical properties of GUVs by modulating membrane composition and lumenal material property. In this context, there have been many different methods developed to test the mechanical properties of GUVs. In this review, we will survey various perturbation techniques employed to mechanically characterize GUVs.
Collapse
Affiliation(s)
- Nadab H. Wubshet
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Allen P. Liu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
- Cellular and Molecular Biology Program, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Biophysics, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
4
|
Cheng Y, Treado JD, Lonial BF, Habdas P, Weeks ER, Shattuck MD, O'Hern CS. Hopper flows of deformable particles. SOFT MATTER 2022; 18:8071-8086. [PMID: 36218162 DOI: 10.1039/d2sm01079h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Numerous experimental and computational studies show that continuous hopper flows of granular materials obey the Beverloo equation that relates the volume flow rate Q and the orifice width w: Q ∼ (w/σavg - k)β, where σavg is the average particle diameter, kσavg is an offset where Q ∼ 0, the power-law scaling exponent β = d - 1/2, and d is the spatial dimension. Recent studies of hopper flows of deformable particles in different background fluids suggest that the particle stiffness and dissipation mechanism can also strongly affect the power-law scaling exponent β. We carry out computational studies of hopper flows of deformable particles with both kinetic friction and background fluid dissipation in two and three dimensions. We show that the exponent β varies continuously with the ratio of the viscous drag to the kinetic friction coefficient, λ = ζ/μ. β = d - 1/2 in the λ → 0 limit and d - 3/2 in the λ → ∞ limit, with a midpoint λc that depends on the hopper opening angle θw. We also characterize the spatial structure of the flows and associate changes in spatial structure of the hopper flows to changes in the exponent β. The offset k increases with particle stiffness until k ∼ kmax in the hard-particle limit, where kmax ∼ 3.5 is larger for λ → ∞ compared to that for λ → 0. Finally, we show that the simulations of hopper flows of deformable particles in the λ → ∞ limit recapitulate the experimental results for quasi-2D hopper flows of oil droplets in water.
Collapse
Affiliation(s)
- Yuxuan Cheng
- Department of Physics, Yale University, New Haven, Connecticut, 06520, USA.
| | - John D Treado
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut, 06520, USA
| | | | - Piotr Habdas
- Department of Physics, Saint Joseph's University, Philadelphia, PA 19131, USA
| | - Eric R Weeks
- Department of Physics, Emory University, Atlanta, GA 30322, USA
| | - Mark D Shattuck
- Benjamin Levich Institute and Physics Department, The City College of New York, New York, New York 10031, USA
| | - Corey S O'Hern
- Department of Physics, Yale University, New Haven, Connecticut, 06520, USA.
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut, 06520, USA
- Program in Computational Biology and Bioinformatics, Yale University, New Haven, Connecticut, 06520, USA
- Department of Applied Physics, Yale University, New Haven, Connecticut, 06520, USA.
| |
Collapse
|
5
|
Chen Y, Guo K, Jiang L, Zhu S, Ni Z, Xiang N. Microfluidic deformability cytometry: A review. Talanta 2022; 251:123815. [DOI: 10.1016/j.talanta.2022.123815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/23/2022] [Accepted: 08/02/2022] [Indexed: 10/15/2022]
|
6
|
Microfluidic Assessment of Drug Effects on Physical Properties of Androgen Sensitive and Non-Sensitive Prostate Cancer Cells. MICROMACHINES 2021; 12:mi12050532. [PMID: 34067167 PMCID: PMC8151345 DOI: 10.3390/mi12050532] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 04/19/2021] [Accepted: 04/28/2021] [Indexed: 12/22/2022]
Abstract
The identification and treatment of androgen-independent prostate cancer are both challenging and significant. In this work, high-throughput deformability cytometry was employed to assess the effects of two anti-cancer drugs, docetaxel and enzalutamide, on androgen-sensitive prostate cancer cells (LNCaP) and androgen-independent prostate cancer cells (PC-3), respectively. The quantified results show that PC-3 and LNCaP present not only different intrinsic physical properties but also different physical responses to the same anti-cancer drug. PC-3 cells possess greater stiffness and a smaller size than LNCaP cells. As the docetaxel concentration increases, PC-3 cells present an increase in stiffness and size, but LNCaP cells only present an increase in stiffness. As the enzalutamide concentration increases, PC-3 cells present no physical changes but LNCaP cells present changes in both cell size and deformation. These results demonstrated that cellular physical properties quantified by the deformability cytometry are effective indicators for identifying the androgen-independent prostate cancer cells from androgen-sensitive prostate cancer cells and evaluating drug effects on these two types of prostate cancer.
Collapse
|
7
|
Chang D, Hirate T, Uehara C, Maruyama H, Uozumi N, Arai F. Evaluating Young's Modulus of Single Yeast Cells Based on Compression Using an Atomic Force Microscope with a Flat Tip. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2021; 27:392-399. [PMID: 33446296 DOI: 10.1017/s1431927620024903] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
In this research, atomic force microscopy (AFM) with a flat tip cantilever is utilized to measure Young's modulus of a whole yeast cell (Saccharomyces cerevisiae BY4741). The results acquired from AFM are similar to those obtained using a microfluidic chip compression system. The mechanical properties of single yeast cells are important parameters which can be examined using AFM. Conventional studies apply AFM with a sharp cantilever tip to indent the cell and measure the force-indentation curve, from which Young's modulus can be calculated. However, sharp tips introduce problems because the shape variation can lead to a different result and cannot represent the stiffness of the whole cell. It can lead to a lack of broader meaning when evaluating Young's modulus of yeast cells. In this report, we confirm the differences in results obtained when measuring the compression of a poly(dimethylsiloxane) bead using a commercial sharp tip versus a unique flat tip. The flat tip effectively avoids tip-derived errors, so we use this method to compress whole yeast cells and generate a force–deformation curve. We believe our proposed method is effective for evaluating Young's modulus of whole yeast cells.
Collapse
Affiliation(s)
- Di Chang
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Room 108, Aerospace Mechanical Engineering Research Building, Furo-cho, Chikusa-ku, Nagoya, Aichi464-8603, Japan
| | - Takahiro Hirate
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Room 108, Aerospace Mechanical Engineering Research Building, Furo-cho, Chikusa-ku, Nagoya, Aichi464-8603, Japan
| | - Chihiro Uehara
- Department of Biomolecular Engineering, Graduate School of Engineering, Tohoku University, Aobayama 6-6-07, Sendai980-8579, Japan
| | - Hisataka Maruyama
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Room 108, Aerospace Mechanical Engineering Research Building, Furo-cho, Chikusa-ku, Nagoya, Aichi464-8603, Japan
| | - Nobuyuki Uozumi
- Department of Biomolecular Engineering, Graduate School of Engineering, Tohoku University, Aobayama 6-6-07, Sendai980-8579, Japan
| | - Fumihito Arai
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Room 108, Aerospace Mechanical Engineering Research Building, Furo-cho, Chikusa-ku, Nagoya, Aichi464-8603, Japan
- Department of Mechanical Engineering, The University of Tokyo, Tokyo113-8654, Japan
| |
Collapse
|
8
|
Liu Y, Xu H, Li T, Wang W. Microtechnology-enabled filtration-based liquid biopsy: challenges and practical considerations. LAB ON A CHIP 2021; 21:994-1015. [PMID: 33710188 DOI: 10.1039/d0lc01101k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Liquid biopsy, an important enabling technology for early diagnosis and dynamic monitoring of cancer, has drawn extensive attention in the past decade. With the rapid developments of microtechnology, it has been possible to manipulate cells at the single-cell level, which dramatically improves the liquid biopsy capability. As the microtechnology-enabled liquid biopsy matures from proof-of-concept demonstrations towards practical applications, a main challenge it is facing now is to process clinical samples which are usually of a large volume while containing very rare targeted cells in complex backgrounds. Therefore, a high-throughput liquid biopsy which is capable of processing liquid samples with a large volume in a reasonable time along with a high recovery rate of rare targeted cells from complex clinical liquids is in high demand. Moreover, the purity, viability and release feasibility of recovered targeted cells are the other three key impact factors requiring careful considerations. To date, among the developed techniques, micropore-type filtration has been acknowledged as the most promising solution to address the aforementioned challenges in practical applications. However, the presently reported studies about micropore-type filtration are mostly based on trial and error for device designs aiming at different cancer types, which requires lots of efforts. Therefore, there is an urgent need to investigate and elaborate the fundamental theories of micropore-type filtration and key features that influence the working performances in the liquid biopsy of real clinical samples to promote the application efficacy in practical applications. In this review, the state of the art of microtechnology-enabled filtration is systematically and comprehensively summarized. Four key features of the filtration, including throughput, purity, viability and release feasibility of the captured targeted cells, are elaborated to provide the guidelines for filter designs. The recent progress in the filtration mode modulation and sample standardization to improve the filtration performance of real clinical samples is also discussed. Finally, this review concludes with prospective views for future developments of filtration-based liquid biopsy to promote its application efficacy in clinical practice.
Collapse
Affiliation(s)
- Yaoping Liu
- Institute of Microelectronics, Peking University, Beijing, 100871, China.
| | | | | | | |
Collapse
|
9
|
Graybill PM, Bollineni RK, Sheng Z, Davalos RV, Mirzaeifar R. A constriction channel analysis of astrocytoma stiffness and disease progression. BIOMICROFLUIDICS 2021; 15:024103. [PMID: 33763160 PMCID: PMC7968935 DOI: 10.1063/5.0040283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 02/23/2021] [Indexed: 05/12/2023]
Abstract
Studies have demonstrated that cancer cells tend to have reduced stiffness (Young's modulus) compared to their healthy counterparts. The mechanical properties of primary brain cancer cells, however, have remained largely unstudied. To investigate whether the stiffness of primary brain cancer cells decreases as malignancy increases, we used a microfluidic constriction channel device to deform healthy astrocytes and astrocytoma cells of grade II, III, and IV and measured the entry time, transit time, and elongation. Calculating cell stiffness directly from the experimental measurements is not possible. To overcome this challenge, finite element simulations of the cell entry into the constriction channel were used to train a neural network to calculate the stiffness of the analyzed cells based on their experimentally measured diameter, entry time, and elongation in the channel. Our study provides the first calculation of stiffness for grades II and III astrocytoma and is the first to apply a neural network analysis to determine cell mechanical properties from a constriction channel device. Our results suggest that the stiffness of astrocytoma cells is not well-correlated with the cell grade. Furthermore, while other non-central-nervous-system cell types typically show reduced stiffness of malignant cells, we found that most astrocytoma cell lines had increased stiffness compared to healthy astrocytes, with lower-grade astrocytoma having higher stiffness values than grade IV glioblastoma. Differences in nucleus-to-cytoplasm ratio only partly explain differences in stiffness values. Although our study does have limitations, our results do not show a strong correlation of stiffness with cell grade, suggesting that other factors may play important roles in determining the invasive capability of astrocytoma. Future studies are warranted to further elucidate the mechanical properties of astrocytoma across various pathological grades.
Collapse
Affiliation(s)
| | - R. K. Bollineni
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia 24061, USA
| | - Z. Sheng
- Department of Internal Medicine, Virginia Tech Carilion School of Medicine and Virginia Tech Fralin Biomedical Research Institute, Roanoke, Virginia 24016, USA
| | - R. V. Davalos
- Authors to whom correspondence should be addressed: and
| | - R. Mirzaeifar
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia 24061, USA
- Authors to whom correspondence should be addressed: and
| |
Collapse
|
10
|
A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel. MICROMACHINES 2019; 10:mi10100645. [PMID: 31557932 PMCID: PMC6843121 DOI: 10.3390/mi10100645] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Revised: 09/20/2019] [Accepted: 09/24/2019] [Indexed: 12/25/2022]
Abstract
The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.
Collapse
|
11
|
Liu N, Du P, Xiao X, Liu Y, Peng Y, Yang C, Yue T. Microfluidic-Based Mechanical Phenotyping of Androgen-Sensitive and Non-sensitive Prostate Cancer Cells Lines. MICROMACHINES 2019; 10:E602. [PMID: 31547397 PMCID: PMC6780375 DOI: 10.3390/mi10090602] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 09/07/2019] [Accepted: 09/10/2019] [Indexed: 12/15/2022]
Abstract
Cell mechanical properties have been identified to characterize cells pathologic states. Here, we report our work on high-throughput mechanical phenotyping of androgen-sensitive and non-sensitive human prostate cancer cell lines based on a morphological rheological microfluidic method. The theory for extracting cells' elastic modulus from their deformation and area, and the used experimental parameters were analyzed. The mechanical properties of three types of prostate cancer cells lines with different sensitivity to androgen including LNCaP, DU145, and PC3 were quantified. The result shows that LNCaP cell was the softest, DU145 was the second softest, and PC3 was the stiffest. Furthermore, atomic force microscopy (AFM) was used to verify the effectiveness of this high-throughput morphological rheological method.
Collapse
Affiliation(s)
- Na Liu
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| | - Panpan Du
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| | - Xiaoxiao Xiao
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| | - Yuanyuan Liu
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| | - Yan Peng
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| | - Chen Yang
- Fudan Institute of Urology, Fudan University, Shanghai 200433, China.
| | - Tao Yue
- School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.
| |
Collapse
|
12
|
Ren X, Ghassemi P, Strobl JS, Agah M. Biophysical phenotyping of cells via impedance spectroscopy in parallel cyclic deformability channels. BIOMICROFLUIDICS 2019; 13:044103. [PMID: 31341524 PMCID: PMC6639115 DOI: 10.1063/1.5099269] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/09/2019] [Indexed: 05/19/2023]
Abstract
This paper describes a new microfluidic biosensor with capabilities of studying single cell biophysical properties. The chip contains four parallel sensing channels, where each channel includes two constriction regions separated by a relaxation region. All channels share a pair of electrodes to record the electrical impedance. Single cell impedance magnitudes and phases at different frequencies were obtained. The deformation and transition time information of cells passing through two sequential constriction regions were gained from the time points on impedance magnitude variations. Constriction channels separated by relaxation regions have been proven to improve the sensitivity of distinguishing single cells. The relaxation region between two sequential constriction channels provides extra time stamps that can be identified in the impedance plots. The new chip allows simultaneous measurement of the biophysical attributes of multiple cells in different channels, thereby increasing the overall throughput of the chip. Using the biomechanical parameters represented by the time stamps in the impedance results, breast cancer cells (MDA-MB-231) and the normal epithelial cells (MCF-10A) could be distinguished by 85%. The prediction accuracy at the single-cell level reached 97% when both biomechanical and bioelectrical parameters were utilized. While the new label-free assay has been tested to distinguish between normal and cancer cells, its application can be extended to include cell-drug interactions and circulating tumor cell detection in blood.
Collapse
Affiliation(s)
| | | | | | - Masoud Agah
- Author to whom correspondence should be addressed:. Telephone: (540) 231-2653
| |
Collapse
|
13
|
A Passive Microfluidic Device Based on Crossflow Filtration for Cell Separation Measurements: A Spectrophotometric Characterization. BIOSENSORS-BASEL 2018; 8:bios8040125. [PMID: 30544881 PMCID: PMC6316345 DOI: 10.3390/bios8040125] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Revised: 12/02/2018] [Accepted: 12/04/2018] [Indexed: 01/04/2023]
Abstract
Microfluidic devices have been widely used as a valuable research tool for diagnostic applications. Particularly, they have been related to the successful detection of different diseases and conditions by assessing the mechanical properties of red blood cells (RBCs). Detecting deformability changes in the cells and being able to separate those cells may be a key factor in assuring the success of detection of some blood diseases with diagnostic devices. To detect and separate the chemically modified RBCs (mimicking disease-infected RBCs) from healthy RBCs, the present work proposes a microfluidic device comprising a sequence of pillars with different gaps and nine different outlets used to evaluate the efficiency of the device by measuring the optical absorption of the collected samples. This latter measurement technique was tested to distinguish between healthy RBCs and RBCs chemically modified with glutaraldehyde. The present study indicates that it was possible to detect a slight differences between the samples using an optical absorption spectrophotometric setup. Hence, the proposed microfluidic device has the potential to perform in one single step a partial passive separation of RBCs based on their deformability.
Collapse
|
14
|
Ren X, Ghassemi P, Kanaan YM, Naab T, Copeland RL, Dewitty RL, Kim I, Strobl JS, Agah M. Kernel-Based Microfluidic Constriction Assay for Tumor Sample Identification. ACS Sens 2018; 3:1510-1521. [PMID: 29979037 DOI: 10.1021/acssensors.8b00301] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A high-throughput multiconstriction microfluidic channels device can distinguish human breast cancer cell lines (MDA-MB-231, HCC-1806, MCF-7) from immortalized breast cells (MCF-10A) with a confidence level of ∼81-85% at a rate of 50-70 cells/min based on velocity increment differences through multiconstriction channels aligned in series. The results are likely related to the deformability differences between nonmalignant and malignant breast cells. The data were analyzed by the methods/algorithms of Ridge, nonnegative garrote on kernel machine (NGK), and Lasso using high-dimensional variables, including the cell sizes, velocities, and velocity increments. In kernel learning based methods, the prediction values of 10-fold cross-validations are used to represent the difference between two groups of data, where a value of 100% indicates the two groups are completely distinct and identifiable. The prediction value is used to represent the difference between two groups using the established algorithm classifier from high-dimensional variables. These methods were applied to heterogeneous cell populations prepared using primary tumor and adjacent normal tissue obtained from two patients. Primary breast cancer cells were distinguished from patient-matched adjacent normal cells with a prediction ratio of 70.07%-75.96% by the NGK method. Thus, this high-throughput multiconstriction microfluidic device together with the kernel learning method can be used to perturb and analyze the biomechanical status of cells obtained from small primary tumor biopsy samples. The resultant biomechanical velocity signatures identify malignancy and provide a new marker for evaluation in risk assessment.
Collapse
Affiliation(s)
- Xiang Ren
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Parham Ghassemi
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | | | | | | | - Robert L. Dewitty
- Howard University
Hospital, Providence Hospital, Washington, DC 20017, United States
| | - Inyoung Kim
- Department of Statistics, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Jeannine S. Strobl
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Masoud Agah
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| |
Collapse
|
15
|
Chang CC, Wang K, Zhang Y, Chen D, Fan B, Hsieh CH, Wang J, Wu MH, Chen J. Mechanical property characterization of hundreds of single nuclei based on microfluidic constriction channel. Cytometry A 2018; 93:822-828. [PMID: 30063818 DOI: 10.1002/cyto.a.23386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 02/18/2018] [Accepted: 04/02/2018] [Indexed: 12/31/2022]
Abstract
As label-free biomarkers, the mechanical properties of nuclei are widely treated as promising biomechanical markers for cell type classification and cellular status evaluation. However, previously reported mechanical parameters were derived from only around 10 nuclei, lacking statistical significances due to low sample numbers. To address this issue, nuclei were first isolated from SW620 and A549 cells, respectively, using a chemical treatment method. This was followed by aspirating them through two types of microfluidic constriction channels for mechanical property characterization. In this study, hundreds of nuclei were characterized, producing passage times of 0.5 ± 1.2 s for SW620 nuclei in type I constriction channel (n = 153), 0.045 ± 0.047 s for SW620 nuclei in type II constriction channel (n = 215) and 0.50 ± 0.86 s for A549 nuclei in type II constriction channel. In addition, neural network based pattern recognition was used to classify the nuclei isolated from SW620 and A549 cells, producing successful classification rates of 87.2% for diameters of nuclei, 85.5% for passage times of nuclei and 89.3% for both passage times and diameters of nuclei. These results indicate that the characterization of the mechanical properties of nuclei may contribute to the classification of different tumor cells.
Collapse
Affiliation(s)
- Chun-Chieh Chang
- Graduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Taoyuan City, Taiwan
| | - Ke Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Yi Zhang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Deyong Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Beiyuan Fan
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Chia-Hsun Hsieh
- Division of Haematology/Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City, Taiwan
| | - Junbo Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Min-Hsien Wu
- Graduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Taoyuan City, Taiwan.,Division of Haematology/Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City, Taiwan
| | - Jian Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, People's Republic of China.,School of Electronic, Electrical and Communication Engineering/School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| |
Collapse
|
16
|
Niu Y, Qi L, Zhang F, Zhao Y. Geometric screening of core/shell hydrogel microcapsules using a tapered microchannel with interdigitated electrodes. Biosens Bioelectron 2018; 112:162-169. [PMID: 29704784 DOI: 10.1016/j.bios.2018.04.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 03/30/2018] [Accepted: 04/17/2018] [Indexed: 10/17/2022]
Abstract
Core/shell hydrogel microcapsules attract increasing research attention due to their potentials in tissue engineering, food engineering, and drug delivery. Current approaches for generating core/shell hydrogel microcapsules suffer from large geometric variations. Geometrically defective core/shell microcapsules need to be removed before further use. High-throughput geometric characterization of such core/shell microcapsules is therefore necessary. In this work, a continuous-flow device was developed to measure the geometric properties of microcapsules with a hydrogel shell and an aqueous core. The microcapsules were pumped through a tapered microchannel patterned with an array of interdigitated microelectrodes. The geometric parameters (the shell thickness and the diameter) were derived from the displacement profiles of the microcapsules. The results show that this approach can successfully distinguish all unencapsulated microparticles. The geometric properties of core/shell microcapsules can be determined with high accuracy. The efficacy of this method was demonstrated through a drug releasing experiment where the optimization of the electrospray process based on geometric screening can lead to controlled and extended drug releasing profiles. This method does not require high-speed optical systems, simplifying the system configuration and making it an indeed miniaturized device. The throughput of up to 584 microcapsules per minute was achieved. This study provides a powerful tool for screening core/shell hydrogel microcapsules and is expected to facilitate the applications of these microcapsules in various fields.
Collapse
Affiliation(s)
- Ye Niu
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, United States; Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, United States
| | - Lin Qi
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, United States
| | - Fen Zhang
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| | - Yi Zhao
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, United States.
| |
Collapse
|
17
|
Bento D, Rodrigues RO, Faustino V, Pinho D, Fernandes CS, Pereira AI, Garcia V, Miranda JM, Lima R. Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements. MICROMACHINES 2018; 9:E151. [PMID: 30424085 PMCID: PMC6187860 DOI: 10.3390/mi9040151] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 03/21/2018] [Accepted: 03/21/2018] [Indexed: 12/30/2022]
Abstract
Techniques, such as micropipette aspiration and optical tweezers, are widely used to measure cell mechanical properties, but are generally labor-intensive and time-consuming, typically involving a difficult process of manipulation. In the past two decades, a large number of microfluidic devices have been developed due to the advantages they offer over other techniques, including transparency for direct optical access, lower cost, reduced space and labor, precise control, and easy manipulation of a small volume of blood samples. This review presents recent advances in the development of microfluidic devices to evaluate the mechanical response of individual red blood cells (RBCs) and microbubbles flowing in constriction microchannels. Visualizations and measurements of the deformation of RBCs flowing through hyperbolic, smooth, and sudden-contraction microchannels were evaluated and compared. In particular, we show the potential of using hyperbolic-shaped microchannels to precisely control and assess small changes in RBC deformability in both physiological and pathological situations. Moreover, deformations of air microbubbles and droplets flowing through a microfluidic constriction were also compared with RBCs deformability.
Collapse
Affiliation(s)
- David Bento
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Raquel O Rodrigues
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- LCM-Laboratory of Catalysis and Materials-Associate Laboratory LSRE/LCM, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Vera Faustino
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal.
| | - Diana Pinho
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
| | - Carla S Fernandes
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - Ana I Pereira
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
- Algoritmi R&D Centre, Campus de Gualtar, University of Minho, 4710-057 Braga, Portugal.
| | - Valdemar Garcia
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- MEtRiCS, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimarães, Portugal.
| |
Collapse
|
18
|
Raj A, Dixit M, Doble M, Sen AK. A combined experimental and theoretical approach towards mechanophenotyping of biological cells using a constricted microchannel. LAB ON A CHIP 2017; 17:3704-3716. [PMID: 28983550 DOI: 10.1039/c7lc00599g] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We report a combined experimental and theoretical technique that enables the characterization of various mechanical properties of biological cells. The cells were infused into a microfluidic device that comprises multiple parallel micro-constrictions to eliminate device clogging and facilitate characterization of cells of different sizes and types on a single device. The extension ratio λ and transit velocity Uc of the cells were measured using high-speed and high-resolution imaging which were then used in a theoretical model to predict the Young's modulus Ec = f(λ, Uc) of the cells. The predicted Young's modulus Ec values for three different cell lines (182 ± 34.74 Pa for MDA MB 231, 360 ± 75 Pa for MCF 10A and, 763 ± 93 Pa for HeLa) compare well with those reported in the literature from micropipette measurements and atomic force microscopy measurement within 10% and 15%, respectively. Also, the Young's modulus of MDA-MB-231 cells treated with 50 μM 4-hyrdroxyacetophenone (for localization of myosin II) for 30 min was found out to be 260 ± 52 Pa. The entry time te of cells into the micro-constrictions was predicted using the model and validated using experimentally measured data. The entry and transit behaviors of cells in the micro-constriction including cell deformation (extension ratio λ) and velocity Uc were experimentally measured and used to predict various cell properties such as the Young's modulus, cytoplasmic viscosity and induced hydrodynamic resistance of different types of cells. The proposed combined experimental and theoretical approach leads to a new paradigm for mechanophenotyping of biological cells.
Collapse
Affiliation(s)
- A Raj
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India.
| | | | | | | |
Collapse
|
19
|
Ren X, Ghassemi P, Babahosseini H, Strobl JS, Agah M. Single-Cell Mechanical Characteristics Analyzed by Multiconstriction Microfluidic Channels. ACS Sens 2017; 2:290-299. [PMID: 28723132 DOI: 10.1021/acssensors.6b00823] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A microfluidic device composed of variable numbers of multiconstriction channels is reported in this paper to differentiate a human breast cancer cell line, MDA-MB-231, and a nontumorigenic human breast cell line, MCF-10A. Differences between their mechanical properties were assessed by comparing the effect of single or multiple relaxations on their velocity profiles which is a novel measure of their deformation ability. Videos of the cells were recorded via a microscope using a smartphone, and imported to a tracking software to gain the position information on the cells. Our results indicated that a multiconstriction channel design with five deformation (50 μm in length, 10 μm in width, and 8 μm in height) separated by four relaxation (50 μm in length, 40 μm in width, and 30 μm in height) regions was superior to a single deformation design in differentiating MDA-MB-231 and MCF-10A cells. Velocity profile criteria can achieve a differentiation accuracy around 95% for both MDA-MB-231 and MCF-10A cells.
Collapse
Affiliation(s)
- Xiang Ren
- The Bradley Department of
Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Parham Ghassemi
- The Bradley Department of
Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Hesam Babahosseini
- The Bradley Department of
Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Jeannine S. Strobl
- The Bradley Department of
Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Masoud Agah
- The Bradley Department of
Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| |
Collapse
|
20
|
Babahosseini H, Strobl JS, Agah M. Microfluidic Iterative Mechanical Characteristics (iMECH) Analyzer for Single-Cell Metastatic Identification. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2017; 9:847-855. [PMID: 29034007 PMCID: PMC5637398 DOI: 10.1039/c6ay03342c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This study describes the development of a microfluidic biosensor called the iterative mechanical characteristics (iMECH) analyzer which enables label-free biomechanical profiling of individual cells for distinction between metastatic and non-metastatic human mammary cell lines. Previous results have demonstrated that pulsed mechanical nanoindentation can modulate the biomechanics of cells resulting in distinctly different biomechanical responses in metastatic and non-metastatic cell lines. The iMECH analyzer aims to move this concept into a microfluidic, clinically more relevant platform. The iMECH analyzer directs a cyclic deformation regimen by pulling cells through a test channel comprised of narrow deformation channels and interspersed with wider relaxation regions which together simulate a dynamic microenvironment. The results of the iMECH analysis of human breast cell lines revealed that cyclic deformations produce a resistance in non-metastatic 184A1 and MCF10A cells as determined by a drop in their average velocity in the iterative deformation channels after each relaxation. In contrast, metastatic MDA-MB-231 and MDA-MB-468 cells exhibit a loss of resistance as measured by a velocity raise after each relaxation. These distinctive modulatory mechanical responses of normal-like non-metastatic and metastatic cancer breast cells to the pulsed indentations paradigm provide a unique bio-signature. The iMECH analyzer represents a diagnostic microchip advance for discriminating metastatic cancer at the single-cell level.
Collapse
Affiliation(s)
- Hesam Babahosseini
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24061, US
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA 24061, US
| | - Jeannine S. Strobl
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA 24061, US
| | - Masoud Agah
- The Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA 24061, US
| |
Collapse
|
21
|
An On-Chip RBC Deformability Checker Significantly Improves Velocity-Deformation Correlation. MICROMACHINES 2016; 7:mi7100176. [PMID: 30404351 PMCID: PMC6190329 DOI: 10.3390/mi7100176] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 09/08/2016] [Accepted: 09/19/2016] [Indexed: 01/01/2023]
Abstract
An on-chip deformability checker is proposed to improve the velocity–deformation correlation for red blood cell (RBC) evaluation. RBC deformability has been found related to human diseases, and can be evaluated based on RBC velocity through a microfluidic constriction as in conventional approaches. The correlation between transit velocity and amount of deformation provides statistical information of RBC deformability. However, such correlations are usually only moderate, or even weak, in practical evaluations due to limited range of RBC deformation. To solve this issue, we implemented three constrictions of different width in the proposed checker, so that three different deformation regions can be applied to RBCs. By considering cell responses from the three regions as a whole, we practically extend the range of cell deformation in the evaluation, and could resolve the issue about the limited range of RBC deformation. RBCs from five volunteer subjects were tested using the proposed checker. The results show that the correlation between cell deformation and transit velocity is significantly improved by the proposed deformability checker. The absolute values of the correlation coefficients are increased from an average of 0.54 to 0.92. The effects of cell size, shape and orientation to the evaluation are discussed according to the experimental results. The proposed checker is expected to be useful for RBC evaluation in medical practices.
Collapse
|
22
|
Wen N, Zhao Z, Fan B, Chen D, Men D, Wang J, Chen J. Development of Droplet Microfluidics Enabling High-Throughput Single-Cell Analysis. Molecules 2016; 21:E881. [PMID: 27399651 PMCID: PMC6272933 DOI: 10.3390/molecules21070881] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 06/27/2016] [Accepted: 06/28/2016] [Indexed: 12/20/2022] Open
Abstract
This article reviews recent developments in droplet microfluidics enabling high-throughput single-cell analysis. Five key aspects in this field are included in this review: (1) prototype demonstration of single-cell encapsulation in microfluidic droplets; (2) technical improvements of single-cell encapsulation in microfluidic droplets; (3) microfluidic droplets enabling single-cell proteomic analysis; (4) microfluidic droplets enabling single-cell genomic analysis; and (5) integrated microfluidic droplet systems enabling single-cell screening. We examine the advantages and limitations of each technique and discuss future research opportunities by focusing on key performances of throughput, multifunctionality, and absolute quantification.
Collapse
Affiliation(s)
- Na Wen
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Zhan Zhao
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Beiyuan Fan
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Deyong Chen
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Dong Men
- Wuhan Institute of Virology, Chinese Academy of Sciences, Wuhan 430071, China.
| | - Junbo Wang
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Jian Chen
- Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| |
Collapse
|
23
|
Development of Microfluidic Systems Enabling High-Throughput Single-Cell Protein Characterization. SENSORS 2016; 16:232. [PMID: 26891303 PMCID: PMC4801608 DOI: 10.3390/s16020232] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 01/21/2016] [Accepted: 02/02/2016] [Indexed: 01/09/2023]
Abstract
This article reviews recent developments in microfluidic systems enabling high-throughput characterization of single-cell proteins. Four key perspectives of microfluidic platforms are included in this review: (1) microfluidic fluorescent flow cytometry; (2) droplet based microfluidic flow cytometry; (3) large-array micro wells (microengraving); and (4) large-array micro chambers (barcode microchips). We examine the advantages and limitations of each technique and discuss future research opportunities by focusing on three key performance parameters (absolute quantification, sensitivity, and throughput).
Collapse
|