1
|
Kalligosfyri PM, Cinti S. 3D Paper-Based Origami Device for Programmable Multifold Analyte Preconcentration. Anal Chem 2024; 96:9773-9779. [PMID: 38845352 DOI: 10.1021/acs.analchem.4c02032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/19/2024]
Abstract
In analytical chemistry, preconcentration represents a critical step able to enhance the accuracy of detection; however, the experimental procedures needed to preconcentrate samples might be characterized by drawbacks regarding the whole analytical process, e.g., being complex, invasive, and/or time-consuming. In this study, a novel 3D paper-based origami device is introduced for multifold analyte preconcentration. Leveraging the benefits of paper-based substrates, the proposed architecture boosts sample preconcentration while minimizing time and tasks for measurements, solely by exploiting the porous and versatile nature of paper-based substrates. In comparison with other paper-based approaches reported in the literature for preconcentration, the present architecture offers the ability to be programmed for obtaining the needed sensitivity increase without sacrificing measurement time. To demonstrate the efficacy of the novel approach, the 3D paper-based origami device was deeply characterized, including the most relevant parameters, i.e., disk size and number, unfolding time, and volume, and subsequently applied for the preconcentration and the detection of various analytes in real matrices, namely, mercury in tap water and glucose in sweat, resulting in a 400% and 300% sensitivity enhancement, respectively. This innovative preconcentration tool addresses the limitations of existing conventional methods, providing increased sensitivity without the use of expensive and time-consuming procedures through only exploiting the intrinsic properties of paper-based substrates and a rationale design. The proposed architecture emerges as a universal tool to be adopted and programmed for various analytical systems and fields of application.
Collapse
Affiliation(s)
| | - Stefano Cinti
- Department of Pharmacy, University of Naples "Federico II", 80131 Naples, Italy
- BAT Center - Interuniversity Center for Studies on Bioinspired Agro- Environmental Technology, University of Naples "Federico II", 80055 Naples, Italy
| |
Collapse
|
2
|
Hua MZ, Li S, Roopesh MS, Lu X. Development of a microfluidic device to enrich and detect zearalenone in food using quantum dot-embedded molecularly imprinted polymers. LAB ON A CHIP 2024; 24:2700-2711. [PMID: 38651374 DOI: 10.1039/d4lc00193a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Mycotoxins are secondary metabolites of certain moulds, prevalent in 60-80% of food crops and many processed products but challenging to eliminate. Consuming mycotoxin-contaminated food and feed can lead to various adverse effects on humans and livestock. Therefore, testing mycotoxin residue levels is critical to ensure food safety. Gold standard analytical methods rely on liquid chromatography coupled with optical detectors or mass spectrometers, which are high-cost with limited capacity. This study reported the successful development of a microfluidic "lab-on-a-chip" device to enrich and detect zearalenone in food samples based on the fluorescence quenching effect of quantum dots and selective affinity of molecularly imprinted polymers (MIPs). The dummy template and functional polymer were synthesized and characterized, and the detailed microfluidic chip design and optimization of the flow conditions in the enrichment module were discussed. The device achieved an enrichment factor of 9.6 (±0.5) in 10 min to quantify zearalenone spiked in food with high recoveries (91-105%) at 1-10 mg kg-1, covering the concerned residue levels in the regulations. Each sample-to-answer test took only 20 min, involving 3 min of manual operation and no advanced equipment. This microfluidic device was mostly reusable, with a replaceable detection module compatible with fluorescence measurement using a handheld fluorometer. To our best knowledge, the reported device was the first application of an MIP-based microfluidic sensor for detecting mycotoxin in real food samples, providing a novel, rapid, portable, and cost-effective tool for monitoring mycotoxin contamination for food safety and security.
Collapse
Affiliation(s)
- Marti Z Hua
- Department of Food Science and Agricultural Chemistry, McGill University Macdonald Campus, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, Quebec, H9X 3V9, Canada.
| | - Shenmiao Li
- Department of Food Science and Agricultural Chemistry, McGill University Macdonald Campus, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, Quebec, H9X 3V9, Canada.
| | - M S Roopesh
- Department of Agricultural, Food, and Nutrition Science, University of Alberta, Edmonton, AB T6G 2R3, Canada
| | - Xiaonan Lu
- Department of Food Science and Agricultural Chemistry, McGill University Macdonald Campus, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, Quebec, H9X 3V9, Canada.
| |
Collapse
|
3
|
Dang VT, Pham VS. Multiphysics analytical and numerical studies of biomolecule preconcentration utilizing ion concentration polarization: a case study of convergent microchannels. Analyst 2024; 149:2252-2271. [PMID: 38470814 DOI: 10.1039/d4an00017j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
A convergent sector in microfluidic devices utilizing ion concentration polarization (ICP) can help increase the preconcentration rate and the concentration enhancement factor (CEF) of biomolecules. In this work, we present a detailed study of the nozzle-like-squeeze effect of a convergent channel on the preconcentration of biomolecules. By numerically solving coupled Nernst-Planck-Poisson-Navier-Stokes governing equations for the 2D channel model, we report the first study on the critical width of a convergent region in the channel to retain the advantage of the nozzle-like-squeeze effect in speeding up preconcentration and augmenting CEF. In addition, we investigated the impact of the location and the dimensions of a convergent sector on the mechanism of biomolecule preconcentration. The location of an ion-selective membrane was also determined to ensure that biomolecules are focused on the convergent region of the channel. Moreover, we introduce analytical studies to compare and verify simulation findings. Specifically, the formulas for the critical dimensions of a convergent channel, location of a preconcentrated biomolecule plug, and position of an ion-selective membrane are presented. Furthermore, important working parameters, including electric potentials and hydrostatic pressures, were examined to scrutinize their effect on convergent concentrators. These detailed analytical solutions and numerical simulation results are consistent with experimental observations, providing deep insights into the ICP phenomenon and the preconcentration mechanism of biomolecules in convergent microfluidic concentration devices.
Collapse
Affiliation(s)
- Van-Truong Dang
- School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam.
| | - Van-Sang Pham
- School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam.
| |
Collapse
|
4
|
Dang VT, Pham VS. Determination of Critical Dimensions of Microchannels to Ensure the Electrokinetic Biomolecule Preconcentration: Analytical and Numerical Studies. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:6051-6064. [PMID: 38437236 DOI: 10.1021/acs.langmuir.4c00300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
Preconcentration of biomolecules based on ion concentration polarization (ICP) has been splendidly applied to various biomedical and chemical processes. However, in many circumstances, biomolecule preconcentration could not occur due to the lack of full studies on the preconcentration mechanism, especially on the effect of microchannel dimensions. In this work, we provide analytical studies on the critical dimensions (minimum and maximum) of microchannels for the preconcentration of biomolecules. These formulas are verified with the numerical results by fully solving the coupled governing equations: Poisson-Nernst-Planck and Navier-Stokes experiments with appropriate boundary conditions and assumptions. In addition, we examine the impact of operational parameters, such as electric potentials and critical external pressures, on the formation of the preconcentration. Moreover, two important results are provided for the first time, including the position of the preconcentrated biomolecule region and the concentration enhancement factor of the biomolecules. These analytical and numerical results are consistent with experimental observations and, therefore, could provide sharp insight into the mechanism of biomolecule preconcentration and give useful guidelines to better design and optimize ICP-based microfluidic preconcentration devices.
Collapse
Affiliation(s)
- Van-Truong Dang
- School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi 100000, Vietnam
| | - Van-Sang Pham
- School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi 100000, Vietnam
| |
Collapse
|
5
|
Lee J, Neustrup MA, Slütter B, O'Mahony C, Bouwstra JA, van der Maaden K. Intradermal Vaccination with PLGA Nanoparticles via Dissolving Microneedles and Classical Injection Needles. Pharm Res 2024; 41:305-319. [PMID: 38332390 PMCID: PMC10879229 DOI: 10.1007/s11095-024-03665-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 01/19/2024] [Indexed: 02/10/2024]
Abstract
PURPOSE A dissolving microneedle array (dMNA) is a vaccine delivery device with several advantages over conventional needles. By incorporating particulate adjuvants in the form of poly(D,L-lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) into the dMNA, the immune response against the antigen might be enhanced. This study aimed to prepare PLGA-NP-loaded dMNA and to compare T-cell responses induced by either intradermally injected aqueous-PLGA-NP formulation or PLGA-NP-loaded dMNA in mice. METHODS PLGA NPs were prepared with microfluidics, and their physicochemical characteristics with regard to encapsulation efficiencies of ovalbumin (OVA) and CpG oligonucleotide (CpG), zeta potentials, polydispersity indexes, and sizes were analysed. PLGA NPs incorporated dMNA was produced with three different dMNA formulations by using the centrifugation method, and the integrity of PLGA NPs in dMNAs was evaluated. The immunogenicity was evaluated in mice by comparing the T-cell responses induced by dMNA and aqueous formulations containing ovalbumin and CpG (OVA/CpG) with and without PLGA NP. RESULTS Prepared PLGA NPs had a size of around 100 nm. The dMNA formulations affected the particle integrity, and the dMNA with poly(vinyl alcohol) (PVA) showed almost no aggregation of PLGA NPs. The PLGA:PVA weight ratio of 1:9 resulted in 100% of penetration efficiency and the fastest dissolution in ex-vivo human skin (< 30 min). The aqueous formulation with soluble OVA/CpG and the aqueous-PLGA-NP formulation with OVA/CpG induced the highest CD4 + T-cell responses in blood and spleen cells. CONCLUSIONS PLGA NPs incorporated dMNA was successfully fabricated and the aqueous formulation containing PLGA NPs induce superior CD4+ and CD8+ T-cell responses.
Collapse
Affiliation(s)
- Jihui Lee
- Division of Biotherapeutics, Leiden Academic Centre for Drug Research, Leiden University, 2333CC, Leiden, the Netherlands
| | - Malene A Neustrup
- Division of Biotherapeutics, Leiden Academic Centre for Drug Research, Leiden University, 2333CC, Leiden, the Netherlands
| | - Bram Slütter
- Division of Biotherapeutics, Leiden Academic Centre for Drug Research, Leiden University, 2333CC, Leiden, the Netherlands
| | - Conor O'Mahony
- Tyndall National Institute, Lee Maltings, Prospect Row, Cork, Ireland
| | - Joke A Bouwstra
- Division of Biotherapeutics, Leiden Academic Centre for Drug Research, Leiden University, 2333CC, Leiden, the Netherlands
| | - Koen van der Maaden
- Division of Biotherapeutics, Leiden Academic Centre for Drug Research, Leiden University, 2333CC, Leiden, the Netherlands.
- Department of Immunology, Leiden University Medical Center, 2300RC, Leiden, the Netherlands.
| |
Collapse
|
6
|
Richard C, Devendran C, Ashtiani D, Cadarso VJ, Neild A. Acoustofluidic cell micro-dispenser for single cell trajectory control. LAB ON A CHIP 2022; 22:3533-3544. [PMID: 35979941 DOI: 10.1039/d2lc00216g] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The precise manipulation of individual cells is a key capability for the study of single cell physiological characteristics or responses to stimuli. Currently, only large cell populations can be transferred with certainty using expensive and laborious flow cytometry platforms. However, when approaching small populations of cells, this task becomes increasingly challenging. Here, we report an effective acoustofluidic micro-dispenser, utilising surface acoustic waves (SAWs), with the ability to trap and release cells on demand, which when combined with an external valve can guide the trajectory of individual cells. We demonstrate single cell trap and release with a single cell trapping effectiveness of 74%, enabling the capability of dispensing a highly controlled amount of cells without any harmful effects. This device has the potential to be easily integrated into a wide range of analytical platforms for applications such as single cell fluorescent imaging and single cell proteomic studies.
Collapse
Affiliation(s)
- Cynthia Richard
- Laboratory for Micro Systems, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
- Applied Micro- and Nanotechnology Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia
| | - Citsabehsan Devendran
- Laboratory for Micro Systems, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
| | - Dariush Ashtiani
- Laboratory for Micro Systems, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
| | - Victor J Cadarso
- Applied Micro- and Nanotechnology Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia
- Centre to Impact Antimicrobial Resistance, Monash University, Clayton, VIC 3800, Australia
| | - Adrian Neild
- Laboratory for Micro Systems, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
| |
Collapse
|
7
|
Shen X, Teo TW, Kong TF. A Technique for Rapid Bacterial-Density Enumeration through Membrane Filtration and Differential Pressure Measurements. MICROMACHINES 2022; 13:mi13081198. [PMID: 36014121 PMCID: PMC9415702 DOI: 10.3390/mi13081198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/25/2022] [Accepted: 07/26/2022] [Indexed: 02/01/2023]
Abstract
In this article, we present a microfluidic technique for the rapid enumeration of bacterial density with a syringe filter to trap bacteria and the quantification of the bacterial density through pressure difference measurement across the membrane. First, we established the baseline differential pressure and hydraulic resistance for a filtration membrane by fully wetting the filter with DI water. Subsequently, when bacteria were infused and trapped at the pores of the membrane, the differential pressure and hydraulic resistance also increased. We characterized the infusion time required for the bacterial sample to achieve a normalized hydraulic resistance of 1.5. An equivalent electric-circuit model and calibration data sets from parametric studies were used to determine the general form of a calibration curve for the prediction of the bacterial density of a bacterial sample. As a proof of concept, we demonstrated through blind tests with Escherichia coli that the device is capable of determining the bacterial density of a sample ranging from 7.3 × 106 to 2.2 × 108 CFU/mL with mean and median accuracies of 87.21% and 91.33%, respectively. The sample-to-result time is 19 min for a sample with lower detection threshold, while for higher-bacterial-density samples the measurement time is further shortened to merely 8 min.
Collapse
Affiliation(s)
- Xinhui Shen
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Ting Wei Teo
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Tian Fook Kong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|
8
|
Alahmad W, Sahragard A, Varanusupakul P. Online and offline preconcentration techniques on paper-based analytical devices for ultrasensitive chemical and biochemical analysis: A review. Biosens Bioelectron 2021; 194:113574. [PMID: 34474275 DOI: 10.1016/j.bios.2021.113574] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/18/2021] [Accepted: 08/18/2021] [Indexed: 12/24/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) have attracted much attention over the past decade. They embody many advantages, such as abundance, portability, cost-effectiveness, and ease of fabrication, making them superior for clinical diagnostics, environmental monitoring, and food safety assurance. Despite these advantages, μPADs lack the high sensitivity to detect many analytes at trace levels than other commercial analytical instruments such as mass spectrometry. Therefore, a preconcentration step is required to enhance their sensitivity. This review focuses on the techniques used to separate and preconcentrate the analytes onto the μPADs, such as ion concentration polarization, isotachophoresis, and field amplification sample stacking. Other separations and preconcentration techniques, including liquid-solid and liquid-liquid extractions coupled with μPADs, are also reviewed and discussed. In addition, the fabrication methods, advantages, disadvantages, and the performance evaluation of the μPADs concerning their precision and accuracy were highlighted and critically assessed. Finally, the challenges and future perspectives have been discussed.
Collapse
Affiliation(s)
- Waleed Alahmad
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| | - Ali Sahragard
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - Pakorn Varanusupakul
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
9
|
Shi H, Jiang S, Liu B, Liu Z, Reis NM. Modern microfluidic approaches for determination of ions. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106845] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
10
|
Ou Y, Cao S, Zhang J, Dong W, Yang Z, Yu Z. Droplet microfluidics on analysis of pathogenic microbes for wastewater-based epidemiology. Trends Analyt Chem 2021; 143:116333. [PMID: 34720276 PMCID: PMC8547957 DOI: 10.1016/j.trac.2021.116333] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Infectious diseases caused by pathogenic microbes have posed a major health issue for the public, such as the ongoing COVID-19 global pandemic. In recent years, wastewater-based epidemiology (WBE) is emerging as an effective and unbiased method for monitoring public health. Despite its increasing importance, the advancement of WBE requires more competent and streamlined analytical platforms. Herein we discuss the interactions between WBE and droplet microfluidics, focusing on the analysis of pathogens in droplets, which is hard to be tackled by traditional analytical tools. We highlight research works from three aspects, namely, quantitation of pathogen biomarkers in droplets, single-cell analysis in droplets, and living cell biosensors in droplets, as well as providing future perspectives on the synergy between WBE and droplet microfluidics.
Collapse
Affiliation(s)
- Yangteng Ou
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, PR China
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Shixiang Cao
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, PR China
| | - Jing Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, PR China
| | - Weiliang Dong
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, PR China
| | - Zhugen Yang
- School of Water, Energy and Environment, Cranfield University, Cranfield, MK43 0AL, UK
| | - Ziyi Yu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, PR China
| |
Collapse
|
11
|
Silva MLS. Microfluidic devices for glycobiomarker detection in cancer. Clin Chim Acta 2021; 521:229-243. [PMID: 34273337 DOI: 10.1016/j.cca.2021.07.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/07/2021] [Accepted: 07/12/2021] [Indexed: 12/20/2022]
Abstract
During oncogenesis, several alterations occur within cells, one of them being the abnormal glycosylation of proteins, resulting in the formation of glycoproteins with aberrant glycan structures, which can be secreted into the blood stream. Their specific association to tumour cells makes them useful indicators (biomarkers) of the oncogenic process and their detection in blood can be employed in different stages of tumour development for early detection, prognosis and therapeutic drug monitoring. Due to the importance of detecting cancer-associated glycoproteins with aberrant glycosylation in blood or serum, analytical methodologies with improved performance are required to ameliorate the laboratorial tests currently used for the detection of these analytes. Microfluidics was created to facilitate the implementation of simple and point-of-care analysis, away from a centralized laboratory. The massive use of microfluidic systems in clinical settings can be seen in pregnancy tests and diabetes control, for example. But what about other clinical domains, such as the detection of glycoproteins with aberrant glycans secreted by tumour cells? Are microfluidic systems helpful in this case? This review analyses the requirements of a microfluidic assay for the detection of low-abundant blood/serum cancer-associated glycoproteins with abnormal glycans and the progresses that have been made in the last years to develop integrated microfluidic devices for this particular application. The diverse microfluidic systems found in literature present, in general, the same analytical performance as the conventional assays but have additional advantages, namely a reduction in assay times, a decrease of sample and reagent consumption and lower costs. The review will also focus on the improvements that are still needed for better biosensing of this type of cancer biomarkers using microfluidic devices.
Collapse
Affiliation(s)
- M Luísa S Silva
- Centre of Chemical Research, Autonomous University of Hidalgo State, Carr. Pachuca-Tulancingo km 4.5, Pachuca, Hidalgo 42076, Mexico.
| |
Collapse
|
12
|
Thompson JR, Davies CD, Clausmeyer J, Crooks RM. Cation‐Specific Electrokinetic Separations Using Prussian Blue Intercalation Reactions. ChemElectroChem 2020. [DOI: 10.1002/celc.202001095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Jonathan R. Thompson
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 United States
| | - Collin D. Davies
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 United States
| | - Jan Clausmeyer
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 United States
| | - Richard M. Crooks
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 United States
| |
Collapse
|
13
|
Bickham AV, Pang C, George BQ, Topham DJ, Nielsen JB, Nordin GP, Woolley AT. 3D Printed Microfluidic Devices for Solid-Phase Extraction and On-Chip Fluorescent Labeling of Preterm Birth Risk Biomarkers. Anal Chem 2020; 92:12322-12329. [PMID: 32829631 DOI: 10.1021/acs.analchem.0c01970] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Solid-phase extraction (SPE) is a general preconcentration method for sample preparation that can be performed on a variety of specimens. The miniaturization of SPE within a 3D printed microfluidic device further allows for fast and simple extraction of analytes while also enabling integration of SPE with other sample preparation and separation methods. Here, we present the development and application of a reversed-phase lauryl methacrylate-based monolith, formed in 3D printed microfluidic devices, which can selectively retain peptides and proteins. The effectiveness of these SPE monoliths and 3D printed microfluidic devices was tested using a panel of nine preterm birth biomarkers of varying hydrophobicities and ranging in mass from 2 to 470 kDa. The biomarkers were selectively retained, fluorescently labeled, and eluted separately from the excess fluorescent label in 3D printed microfluidic systems. These are the first results demonstrating microfluidic analysis processes on a complete panel of preterm birth biomarkers, an important step toward developing a miniaturized, fully integrated analysis system.
Collapse
Affiliation(s)
- Anna V Bickham
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| | - Chao Pang
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| | - Benjamin Q George
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| | - David J Topham
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| | - Jacob B Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, Utah 84602 United States
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States
| |
Collapse
|
14
|
Richard C, Neild A, Cadarso VJ. The emerging role of microfluidics in multi-material 3D bioprinting. LAB ON A CHIP 2020; 20:2044-2056. [PMID: 32459222 DOI: 10.1039/c9lc01184f] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
To assist the transition of 3D bioprinting technology from simple lab-based tissue fabrication, to fully functional and implantable organs, the technology must not only provide shape control, but also functional control. This can be accomplished by replicating the cellular composition of the native tissue at the microscale, such that cell types interact to provide the desired function. There is therefore a need for precise, controllable, multi-material printing that could allow for high, possibly even single cell, resolution. This paper aims to draw attention to technological advancements made in 3D bioprinting that target the lack of multi-material, and/or multi cell-type, printing capabilities of most current devices. Unlike other reviews in the field, which largely focus on variations in single-material 3D bioprinting involving the standard methods of extrusion-based, droplet-based, laser-based, or stereolithographic methods; this review concentrates on sophisticated multi-material 3D bioprinting using multi-cartridge printheads, co-axial nozzles and microfluidic-enhanced printing nozzles.
Collapse
Affiliation(s)
- Cynthia Richard
- Laboratory for Micro Systems, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
| | | | | |
Collapse
|
15
|
Dincau B, Dressaire E, Sauret A. Pulsatile Flow in Microfluidic Systems. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1904032. [PMID: 31657131 DOI: 10.1002/smll.201904032] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 09/17/2019] [Indexed: 06/10/2023]
Abstract
This review describes the current knowledge and applications of pulsatile flow in microfluidic systems. Elements of fluid dynamics at low Reynolds number are first described in the context of pulsatile flow. Then the practical applications in microfluidic processes are presented: the methods to generate a pulsatile flow, the generation of emulsion droplets through harmonic flow rate perturbation, the applications in mixing and particle separation, and the benefits of pulsatile flow for clog mitigation. The second part of the review is devoted to pulsatile flow in biological applications. Pulsatile flows can be used for mimicking physiological systems, to alter or enhance cell cultures, and for bioassay automation. Pulsatile flows offer unique advantages over a steady flow, especially in microfluidic systems, but also require some new physical insights and more rigorous investigation to fully benefit future applications.
Collapse
Affiliation(s)
- Brian Dincau
- Department of Mechanical Engineering, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
| | - Emilie Dressaire
- Department of Mechanical Engineering, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
| | - Alban Sauret
- Department of Mechanical Engineering, University of California, Santa Barbara, Santa Barbara, CA, 93106, USA
| |
Collapse
|
16
|
Perera ATK, Phan DT, Pudasaini S, Liu Y, Yang C. Enhanced sample pre-concentration by ion concentration polarization on a paraffin coated converging microfluidic paper based analytical platform. BIOMICROFLUIDICS 2020; 14:014103. [PMID: 31933713 PMCID: PMC6941944 DOI: 10.1063/1.5133946] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 12/23/2019] [Indexed: 05/02/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) represent a modest and feasible alternative for conventional analytical methods. However, the inadequate sensitivity of these devices limits the possible applications of μPADs. In this scenario, inducing ion concentration polarization (ICP) on μPADs has shown promise to overcome this limitation by preconcentrating the analytes of interest. Here, we report a μPAD implementing ICP using an off-shelf Nafion® membrane as the perm selective membrane. Two types of devices with a geometrical configuration of a straight channel converging at the middle connecting to circular reservoirs at the end of channels were fabricated. The devices are comprised of a single input channel and an absorption channel. The Nafion membrane is attached to the absorption channel of the device, which is encased by heating with paraffin films at both sides to lower the electro-osmotic flow generated by an applied DC electric field that is needed for ICP. The field induced ICP enables obtaining a maximum concentration factor of more than 2000 folds for fluorescein sodium salt solution on the μPAD. Also, since evaporation of the sample solution was reported to be of great influence on the concentration factor, we analyze the effect of sample solution evaporation on sample preconcentration. Furthermore, our reported fabrication method for μPAD can lower the fabrication cost down to 0.3 USD. This device shows the potential to be developed for serving as a diagnostic and environmental monitoring platform.
Collapse
Affiliation(s)
| | - Dinh-Tuan Phan
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, Maryland 21218, USA
| | - Sanam Pudasaini
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
| | - Yu Liu
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
| | - Chun Yang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
| |
Collapse
|
17
|
Montes RJ, Ladd AJC, Butler JE. Transverse migration and microfluidic concentration of DNA using Newtonian buffers. BIOMICROFLUIDICS 2019; 13:044104. [PMID: 31893007 PMCID: PMC6932854 DOI: 10.1063/1.5110718] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 06/30/2019] [Indexed: 06/10/2023]
Abstract
We present experimental evidence that DNA can be concentrated due to an electrohydrodynamic coupling between a pressure-driven flow and a parallel electric field. The effects of buffer properties on the process were measured in a microfluidic channel. The concentration rates and the efficiency of trapping DNA were quantified as functions of the ion and polymer concentrations of the buffer solution. Buffers with large ion concentrations hindered the ability to trap DNA, reducing the short-time efficiency of the concentration process from nearly 100% to zero. Importantly, DNA was trapped in the microfluidic channel even when the buffer solution lacked any measurable viscoelastic response. These observations indicate that electrohydrodynamic migration drives the concentration of DNA. We found no evidence of viscoelastic migration in these experiments.
Collapse
Affiliation(s)
- Ryan J Montes
- Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611, USA
| | - Anthony J C Ladd
- Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611, USA
| | - Jason E Butler
- Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611, USA
| |
Collapse
|
18
|
Petralia S, Motta D, Conoci S. EWOD silicon biosensor for multiple nucleic acids analysis. Biotechnol Bioeng 2019; 116:2087-2094. [DOI: 10.1002/bit.26987] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/26/2019] [Accepted: 04/05/2019] [Indexed: 11/09/2022]
Affiliation(s)
| | - Daniele Motta
- Distretto Tecnologico Sicilia Micro e Nano Sistemi, VIII Strada, 5‐Zona IndustrialeCatania Italy
| | | |
Collapse
|
19
|
Conformation and Dynamics of Long-Chain End-Tethered Polymers in Microchannels. Polymers (Basel) 2019; 11:polym11030488. [PMID: 30960472 PMCID: PMC6473708 DOI: 10.3390/polym11030488] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 02/25/2019] [Accepted: 02/27/2019] [Indexed: 12/14/2022] Open
Abstract
Polyelectrolytes constitute an important group of materials, used for such different purposes as the stabilization of emulsions and suspensions or oil recovery. They are also studied and utilized in the field of microfluidics. With respect to the latter, a part of the interest in polyelectrolytes inside microchannels stems from genetic analysis, considering that deoxyribonucleic acid (DNA) molecules are polyelectrolytes. This review summarizes the single-molecule experimental and molecular dynamics simulation-based studies of end-tethered polyelectrolytes, especially addressing their relaxation dynamics and deformation characteristics under various external forces in micro-confined environments. In most of these studies, DNA is considered as a model polyelectrolyte. Apart from summarizing the results obtained in that area, the most important experimental and simulation techniques are explained.
Collapse
|
20
|
Yew M, Ren Y, Koh KS, Sun C, Snape C. A Review of State-of-the-Art Microfluidic Technologies for Environmental Applications: Detection and Remediation. GLOBAL CHALLENGES (HOBOKEN, NJ) 2019; 3:1800060. [PMID: 31565355 PMCID: PMC6383963 DOI: 10.1002/gch2.201800060] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 08/09/2018] [Indexed: 05/17/2023]
Abstract
Microfluidic systems have advanced beyond natural and life science applications and lab-on-a-chip uses. A growing trend of employing microfluidic technologies for environmental detection has emerged thanks to the precision, time-effectiveness, and cost-effectiveness of advanced microfluidic systems. This paper reviews state-of-the-art microfluidic technologies for environmental applications, such as on-site environmental monitoring and detection. Microdevices are extensively used in collecting environmental samples as a means to facilitate detection and quantification of targeted components with minimal quantities of samples. Likewise, microfluidic-inspired approaches for separation and treatment of contaminated water and air, such as the removal of heavy metals and waterborne pathogens from wastewater and carbon capture are also investigated.
Collapse
Affiliation(s)
- Maxine Yew
- Department of MechanicalMaterials and Manufacturing EngineeringUniversity of Nottingham Ningbo China199 Taikang East Road315100NingboChina
| | - Yong Ren
- Department of MechanicalMaterials and Manufacturing EngineeringUniversity of Nottingham Ningbo China199 Taikang East Road315100NingboChina
| | - Kai Seng Koh
- School of Engineering and Physical SciencesHeriot‐Watt University MalaysiaNo. 1 Jalan Venna P5/2, Precinct 562200PutrajayaMalaysia
| | - Chenggong Sun
- Faculty of EngineeringUniversity of NottinghamThe Energy Technologies Building, Jubilee CampusNottinghamNG7 2TUUK
| | - Colin Snape
- Faculty of EngineeringUniversity of NottinghamThe Energy Technologies Building, Jubilee CampusNottinghamNG7 2TUUK
| |
Collapse
|
21
|
Usman M, Guo X, Wu Q, Barman J, Su S, Huang B, Biao T, Zhang Z, Zhan Q. Facile silicone oil-coated hydrophobic surface for surface enhanced Raman spectroscopy of antibiotics. RSC Adv 2019; 9:14109-14115. [PMID: 35519331 PMCID: PMC9064153 DOI: 10.1039/c9ra00817a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Accepted: 04/03/2019] [Indexed: 01/24/2023] Open
Abstract
The proposed facile, cost-effective slippery surface and gold nanorods based combinational approach for the SERS detection technique is a powerful strategy for the trace detection of the aqueous pollutant analytes even at very low concentrations.
Collapse
Affiliation(s)
- Muhammad Usman
- Centre for Optical and Electromagnetic Research
- Guangdong Provincial Key Laboratory of Optical Information Materials and Technology
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
| | - Xin Guo
- Centre for Optical and Electromagnetic Research
- Guangdong Provincial Key Laboratory of Optical Information Materials and Technology
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
| | - Qiusheng Wu
- Centre for Optical and Electromagnetic Research
- Guangdong Provincial Key Laboratory of Optical Information Materials and Technology
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
| | - Jitesh Barman
- Electronic Paper Display Institute
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
- China
| | - Shaoqiang Su
- Institute of Advanced Materials
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
- China
| | - Bingru Huang
- Centre for Optical and Electromagnetic Research
- Guangdong Provincial Key Laboratory of Optical Information Materials and Technology
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
| | - Tang Biao
- Electronic Paper Display Institute
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
- China
| | - Zhang Zhang
- Institute of Advanced Materials
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
- China
| | - Qiuqiang Zhan
- Centre for Optical and Electromagnetic Research
- Guangdong Provincial Key Laboratory of Optical Information Materials and Technology
- South China Academy of Advanced Optoelectronics
- South China Normal University
- 510006 Guangzhou
| |
Collapse
|
22
|
Fan L, Zhu X, Yan Q, Zhe J, Zhao L. A passive microfluidic device for continuous microparticle enrichment. Electrophoresis 2018; 40:1000-1009. [DOI: 10.1002/elps.201800454] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 11/13/2018] [Accepted: 11/22/2018] [Indexed: 12/18/2022]
Affiliation(s)
- Liang‐Liang Fan
- School of Food Equipment Engineering and Science Xi'an Jiaotong University Xi'an Shaanxi P. R. China
- School of Mechanical Engineering Xi'an Jiaotong University Xi'an Shaanxi P. R. China
- State Key Laboratory of Multiphase Flow in Power Engineering Xi'an Jiaotong University Xi'an Shaanxi P. R. China
| | - Xiao‐Liang Zhu
- Department of Mechanical Engineering University of Akron Akron OH USA
| | - Qing Yan
- State Key Laboratory of Multiphase Flow in Power Engineering Xi'an Jiaotong University Xi'an Shaanxi P. R. China
| | - Jiang Zhe
- Department of Mechanical Engineering University of Akron Akron OH USA
| | - Liang Zhao
- State Key Laboratory of Multiphase Flow in Power Engineering Xi'an Jiaotong University Xi'an Shaanxi P. R. China
| |
Collapse
|
23
|
Malbec R, Cacheux J, Cordelier P, Leichlé T, Joseph P, Bancaud A. Microfluidics for minute DNA sample analysis: open challenges for genetic testing of cell-free circulating DNA in blood plasma. MICRO AND NANO ENGINEERING 2018. [DOI: 10.1016/j.mne.2018.10.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
24
|
AbdelFatah T, Jalali M, Mahshid S. A nanofilter for fluidic devices by pillar-assisted self-assembly microparticles. BIOMICROFLUIDICS 2018; 12:064103. [PMID: 30519372 PMCID: PMC6242779 DOI: 10.1063/1.5048623] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 11/02/2018] [Indexed: 05/17/2023]
Abstract
We present a nanofilter based on pillar-assisted self-assembly microparticles for efficient capture of bacteria. Under an optimized condition, we simply fill the arrays of microscale pillars with submicron scale polystyrene particles to create a filter with nanoscale pore diameter in the range of 308 nm. The design parameters such as the pillar diameter and the inter-pillar spacing in the range of 5 μm-40 μm are optimized using a multi-physics finite element analysis and computational study based on bi-directionally coupled laminar flow and particle tracking solvers. The underlying dynamics of microparticles accumulation in the pillar array region are thoroughly investigated by studying the pillar wall shear stress and the filter pore diameter. The impact of design parameters on the device characteristics such as microparticles entrapment efficiency, pressure drop, and inter-pillar flow velocity is studied. We confirm a bell-curve trend in the capture efficiency versus inter-pillar spacing. Accordingly, the 10 μm inter-pillar spacing offers the highest capture capability (58.8%), with a decreasing entrapping trend for devices with larger inter-pillar spacing. This is the case that the 5 μm inter-pillar spacing demonstrates the highest pillar wall shear stress limiting its entrapping efficiency. As a proof of concept, fluorescently labeled Escherichia coli bacteria (E. coli) were captured using the proposed device. This device provides a simple design, robust operation, and ease of use. All of which are essential attributes for point of care devices.
Collapse
Affiliation(s)
- Tamer AbdelFatah
- Department of Bioengineering, McGill University, Montreal, Quebec H3A 0E9, Canada
| | - Mahsa Jalali
- Department of Bioengineering, McGill University, Montreal, Quebec H3A 0E9, Canada
| | - Sara Mahshid
- Department of Bioengineering, McGill University, Montreal, Quebec H3A 0E9, Canada
| |
Collapse
|
25
|
Šlampová A, Malá Z, Gebauer P. Recent progress of sample stacking in capillary electrophoresis (2016-2018). Electrophoresis 2018; 40:40-54. [PMID: 30073675 DOI: 10.1002/elps.201800261] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 07/31/2018] [Accepted: 07/31/2018] [Indexed: 01/03/2023]
Abstract
Electrophoretic sample stacking comprises a group of capillary electrophoretic techniques where trace analytes from the sample are concentrated into a short zone (stack). This paper is a continuation of our previous reviews on the topic and brings a survey of more than 120 papers published approximately since the second quarter of 2016 till the first quarter of 2018. It is organized according to the particular stacking principles and includes chapters on concentration adjustment (Kohlrausch) stacking, on stacking techniques based on pH changes, on stacking in electrokinetic chromatography and on other stacking techniques. Where available, explicit information is given about the procedure, electrolyte(s) used, detector employed and sensitivity reached. Not reviewed are papers on transient isotachophoresis which are covered by another review in this issue.
Collapse
Affiliation(s)
- Andrea Šlampová
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Zdena Malá
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Petr Gebauer
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| |
Collapse
|
26
|
Gong L, Ouyang W, Li Z, Han J. Force fields of charged particles in micro-nanofluidic preconcentration systems. AIP ADVANCES 2017; 7:125020. [PMID: 29308297 PMCID: PMC5739909 DOI: 10.1063/1.5008365] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Accepted: 12/11/2017] [Indexed: 05/11/2023]
Abstract
Electrokinetic concentration devices based on the ion concentration polarization (ICP) phenomenon have drawn much attention due to their simple setup, high enrichment factor, and easy integration with many subsequent processes, such as separation, reaction, and extraction etc. Despite significant progress in the experimental research, fundamental understanding and detailed modeling of the preconcentration systems is still lacking. The mechanism of the electrokinetic trapping of charged particles is currently limited to the force balance analysis between the electric force and fluid drag force in an over-simplified one-dimensional (1D) model, which misses many signatures of the actual system. This letter studies the particle trapping phenomena that are not explainable in the 1D model through the calculation of the two-dimensional (2D) force fields. The trapping of charged particles is shown to significantly distort the electric field and fluid flow pattern, which in turn leads to the different trapping behaviors of particles of different sizes. The mechanisms behind the protrusions and instability of the focused band, which are important factors determining overall preconcentration efficiency, are revealed through analyzing the rotating fluxes of particles in the vicinity of the ion-selective membrane. The differences in the enrichment factors of differently sized particles are understood through the interplay between the electric force and convective fluid flow. These results provide insights into the electrokinetic concentration effect, which could facilitate the design and optimization of ICP-based preconcentration systems.
Collapse
Affiliation(s)
- Lingyan Gong
- Institute of Laser and Optoelectronic Intelligent Manufacturing, College of Mechanical and Electrical Engineering, Wenzhou University, Wenzhou 325035, P.R. China
| | - Wei Ouyang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Zirui Li
- Institute of Laser and Optoelectronic Intelligent Manufacturing, College of Mechanical and Electrical Engineering, Wenzhou University, Wenzhou 325035, P.R. China
| | | |
Collapse
|
27
|
Fu LM, Hou HH, Chiu PH, Yang RJ. Sample preconcentration from dilute solutions on micro/nanofluidic platforms: A review. Electrophoresis 2017; 39:289-310. [DOI: 10.1002/elps.201700340] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 09/18/2017] [Accepted: 09/20/2017] [Indexed: 11/06/2022]
Affiliation(s)
- Lung-Ming Fu
- Graduate Institute of Materials Engineering; National Pingtung University of Science and Technology; Pingtung Taiwan
- Department of Biomechatronics Engineering; National Pingtung University of Science and Technology; Pingtung Taiwan
| | - Hui-Hsiung Hou
- Department of Engineering Science; National Cheng Kung University; Tainan Taiwan
| | - Ping-Hsien Chiu
- Graduate Institute of Materials Engineering; National Pingtung University of Science and Technology; Pingtung Taiwan
| | - Ruey-Jen Yang
- Department of Engineering Science; National Cheng Kung University; Tainan Taiwan
| |
Collapse
|
28
|
Zhao C, Ge Z, Song Y, Yang C. Electrokinetically driven continuous-flow enrichment of colloidal particles by Joule heating induced temperature gradient focusing in a convergent-divergent microfluidic structure. Sci Rep 2017; 7:10803. [PMID: 28883550 PMCID: PMC5589950 DOI: 10.1038/s41598-017-11473-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Accepted: 08/22/2017] [Indexed: 12/02/2022] Open
Abstract
Enrichment of colloidal particles in continuous flow has not only numerous applications but also poses a great challenge in controlling physical forces that are required for achieving particle enrichment. Here, we for the first time experimentally demonstrate the electrokinetically-driven continuous-flow enrichment of colloidal particles with Joule heating induced temperature gradient focusing (TGF) in a microfluidic convergent-divergent structure. We consider four mechanisms of particle transport, i.e., advection due to electroosmosis, electrophoresis, dielectrophoresis and, and further clarify their roles in the particle enrichment. It is experimentally determined and numerically verified that the particle thermophoresis plays dominant roles in enrichment of all particle sizes considered in this study and the combined effect of electroosmosis-induced advection and electrophoresis is mainly to transport particles to the zone of enrichment. Specifically, the enrichment of particles is achieved with combined DC and AC voltages rather than a sole DC or AC voltage. A numerical model is formulated with consideration of the abovementioned four mechanisms, and the model can rationalize the experimental observations. Particularly, our analysis of numerical and experimental results indicates that thermophoresis which is usually an overlooked mechanism of material transport is crucial for the successful electrokinetic enrichment of particles with Joule heating induced TGF.
Collapse
Affiliation(s)
- Cunlu Zhao
- Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Zhengwei Ge
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Yongxin Song
- Department of Marine Engineering, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, China
| | - Chun Yang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore.
| |
Collapse
|
29
|
Hu Q, Ren Y, Liu W, Tao Y, Jiang H. Simulation Analysis of Improving Microfluidic Heterogeneous Immunoassay Using Induced Charge Electroosmosis on a Floating Gate. MICROMACHINES 2017; 8:E212. [PMID: 30400403 PMCID: PMC6190211 DOI: 10.3390/mi8070212] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 07/02/2017] [Accepted: 07/03/2017] [Indexed: 11/16/2022]
Abstract
On-chip immuno-sensors are a hot topic in the microfluidic community, which is usually limited by slow diffusion-dominated transport of analytes in confined microchannels. Specifically, the antigen-antibody binding reaction at a functionalized area cannot be provided with enough antigen source near the reaction surface, since a small diffusion flux cannot match with the quick rate of surface reaction, which influences the response time and sensitivity of on-chip heterogeneous immunoassay. In this work, we propose a method to enhance the transportation of biomolecules to the surface of an antibody-immobilized electrode with induce charge electroosmotic (ICEO) convection in a low concentration suspension, so as to improve the binding efficiency of microfluidic heterogeneous immunoassays. The circular stirring fluid motion of ICEO on the surface of a floating gate electrode at the channel bottom accelerates the transport of freely suspended antigen towards the wall-immobilized antibodies. We investigate the dependence of binding efficiency on voltage magnitude and field frequency of the applied alternate current (AC) electrical field. The binding rate yields a factor of 5.4 higher binding for an applied voltage of 4 V at 10 Hz when the Damkohler number is 1000. The proposed microfluidic immuno-sensor technology of a simple electrode structure using ICEO convective fluid flow around floating conductors could offer exciting opportunities for diffusion-limited on-chip bio-microfluidic sensors.
Collapse
Affiliation(s)
- Qingming Hu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- School of Mechatronics Engineering, Qiqihar University, Wenhua Street 42, Qiqihar 161006, Heilongjiang, China.
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| | - Weiyu Liu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- School of Electronics and Control Engineering, Chang'an University, Middle-section of Nan'erHuan Road, Xi'an 710064, Shaanxi, China.
| | - Ye Tao
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| |
Collapse
|
30
|
Garcia-Cordero JL, Fan ZH. Sessile droplets for chemical and biological assays. LAB ON A CHIP 2017; 17:2150-2166. [PMID: 28561839 DOI: 10.1039/c7lc00366h] [Citation(s) in RCA: 79] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Sessile droplets are non-movable droplets spanning volumes in the nL-to-μL range. The sessile-droplet-based platform provides a paradigm shift from the conventional, flow-based lab-on-a-chip philosophy, yet offering similar benefits: low reagent/sample consumption, high throughput, automation, and most importantly flexibility and versatility. Moreover, the platform relies less heavily on sophisticated fabrication techniques, often sufficient with a hydrophobic substrate, and no pump is required for operation. In addition, exploiting the physical phenomena that naturally arise when a droplet evaporates, such as the coffee-ring effect or Marangoni flow, can lead to fascinating applications. In this review, we introduce the physics of droplets, and then focus on the different types of chemical and biological assays that have been implemented in sessile droplets, including analyte concentration, particle separation and sorting, cell-based assays, and nucleic acid amplification. Finally, we provide our perspectives on this unique micro-scale platform.
Collapse
Affiliation(s)
- Jose L Garcia-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (Cinvestav-IPN), Via del Conocimiento 201, Parque PIIT, Apodaca, NL, CP. 66628 Mexico.
| | | |
Collapse
|